1
|
Mesyngier N, Bailey RC. Multiparametric, Label-Free Analysis of Microfluidic Droplets via a Dynamic Phase Grating Approach. Anal Chem 2023; 95:12605-12612. [PMID: 37585356 DOI: 10.1021/acs.analchem.2c05102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Abstract
Droplet-based microfluidic systems possess many fundamental advantages as a platform for the analysis of chemical and biological species. However, whereas on-chip operations have rapidly developed over the past decades, approaches for analyzing target molecules within droplets have largely remained limited to methods requiring bulky and expensive instrumentation. In this work, we describe a droplet analysis approach whereby the droplet train itself is the sensing construct. Specifically, the droplet train is interrogated as a transmission phase grating, allowing high-throughput, label-free, solution-phase, and multi-parametric analysis of droplet contents. Importantly, three distinct properties of generated droplets can be simultaneously extracted using this conceptually simple and experimentally straightforward measurement approach. Under constant droplet generation conditions, measurement of droplet viscosity is achieved by monitoring changes in zero order to first order peak separation in the far-field diffraction pattern, with a sensitivity of 2.28 × 10-4 cSt per μm change in peak separation. In parallel, measurement of droplet refractive index (RI) is achieved by measuring changes in the ratio of the zero order to first order peak intensity, with a sensitivity of 2.14 × 10-4 RI units per unit change in a diffracted peak intensity ratio. Finally, droplet generation frequency is determined from the time-varying oscillation of the peak height ratio, yielding comparable results to an expensive high-speed camera commonly used for droplet imaging. Importantly, the experimental strategy for this approach is straightforward and does not require expensive instrumentation; therefore, it may find utility in affordable and portable analysis approaches applied to diverse droplet microfluidic assays.
Collapse
Affiliation(s)
- Nicolas Mesyngier
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Ryan C Bailey
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
2
|
Tan BH, An H, Ohl CD. Body Forces Drive the Apparent Line Tension of Sessile Droplets. PHYSICAL REVIEW LETTERS 2023; 130:064003. [PMID: 36827583 DOI: 10.1103/physrevlett.130.064003] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 12/05/2022] [Indexed: 06/18/2023]
Abstract
The line tension of a three-phase contact line is implicated in a wide variety of interfacial phenomena, but there is ongoing controversy, with existing measurements spanning six orders of magnitude in both signs. Here, we show that computationally obtained magnitudes, sign changes, and nontrivial variations of apparent line tension can be faithfully reproduced in a parsimonious model that incorporates only liquid-substrate interactions. Our results suggest that the origin for the remarkable variation lies in the failure of a widely used estimation method to eliminate body forces, leading measured line tensions to behave like an extensive quantity.
Collapse
Affiliation(s)
- Beng Hau Tan
- KB Corporation, The Plaza, 7500A Beach Road, 199591, Singapore
| | - Hongjie An
- Queensland Micro and Nanotechnology Centre, Griffith University, 170 Kessels Road, Nathan, Queensland 4111, Australia
| | - Claus-Dieter Ohl
- Institute of Physics, Otto von Guericke University Magdeburg, Universitätsplatz 2, 39016 Magdeburg, Germany
| |
Collapse
|
3
|
Liang L, Hu X, Shi Y, Zhao S, Hu Q, Liang M, Ai Y. Tunable and Dynamic Optofluidic Microlens Arrays Based on Droplets. Anal Chem 2022; 94:14938-14946. [PMID: 36263633 DOI: 10.1021/acs.analchem.2c02437] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Microlens arrays (MLAs) are acquiring a key role in the micro-optical system, which have been widely applied in the fields of imaging processing, light extraction, biochemical sensing, and display technology. Compared with solid MLAs, liquid MLAs have received extensive attention due to their natural smooth interface and adjustability. However, manufacturing tunable liquid MLAs with ideal structures is still a key challenge for current technologies. In this paper, a novel and simple optofluidic method is demonstrated, enabling the tunable focusing and high-quality imaging of liquid MLAs. Tunable droplets are fabricated and self-assembled into arrays as the MLAs, which can be easily adjusted to focus, form images, and display different focal lengths. Tuning of MLAs' focusing properties (range from 550 to 5370 μm) is demonstrated by changing the refractive index (RI) of the droplets with a fixed size of 200 μm, which can be changed by adjusting the flow rates of the two branch streams. Also, the corresponding numerical apertures of the MLAs range from 0.026 to 0.26. Furthermore, the MLAs' functionality for microparticle imaging applications is also illustrated. Combining the MLAs with a 4× objective, microparticle imaging is magnified two times, and the resolution has also been improved on the original basis. Besides, both the size and RI of the MLAs in an optofluidic chip can be further adjusted to detect samples at different positions. These MLAs have the merits of high optical performance, a simple fabrication procedure, easy integration, and good tunability. Thus, it shows promising opportunities for many applications, such as adaptive imaging and sensing.
Collapse
Affiliation(s)
- Li Liang
- School of Physics and Electronic Technology, Anhui Normal University, Wuhu241000, China
| | - Xuejia Hu
- School of Electronic Science and Engineering, Xiamen University, Xiamen361005, China
| | - Yang Shi
- Institute of Nanophotonics, Jinan University, Guangzhou511443, China
| | - Shukun Zhao
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan430072, China
| | - Qinghao Hu
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan430072, China
| | - Minhui Liang
- Pillar of Engineering Product Development, Singapore University of Technology and Design, Singapore487372, Singapore
| | - Ye Ai
- Pillar of Engineering Product Development, Singapore University of Technology and Design, Singapore487372, Singapore
| |
Collapse
|
4
|
Lovšin M, Brandl D, Glavan G, Belyaeva IA, Cmok L, Čoga L, Kalin M, Shamonin M, Drevenšek-Olenik I. Reconfigurable Surface Micropatterns Based on the Magnetic Field-Induced Shape Memory Effect in Magnetoactive Elastomers. Polymers (Basel) 2021; 13:polym13244422. [PMID: 34960973 PMCID: PMC8708412 DOI: 10.3390/polym13244422] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 12/10/2021] [Accepted: 12/14/2021] [Indexed: 11/20/2022] Open
Abstract
A surface relief grating with a period of 30 µm is embossed onto the surface of magnetoactive elastomer (MAE) samples in the presence of a moderate magnetic field of about 180 mT. The grating, which is represented as a set of parallel stripes with two different amplitude reflectivity coefficients, is detected via diffraction of a laser beam in the reflection configuration. Due to the magnetic-field-induced plasticity effect, the grating persists on the MAE surface for at least 90 h if the magnetic field remains present. When the magnetic field is removed, the diffraction efficiency vanishes in a few minutes. The described effect is much more pronounced in MAE samples with larger content of iron filler (80 wt%) than in the samples with lower content of iron filler (70 wt%). A simple theoretical model is proposed to describe the observed dependence of the diffraction efficiency on the applied magnetic field. Possible applications of MAEs as magnetically reconfigurable diffractive optical elements are discussed. It is proposed that the described experimental method can be used as a convenient tool for investigations of the dynamics of magnetically induced plasticity of MAEs on the micrometer scale.
Collapse
Affiliation(s)
- Matija Lovšin
- Department of Complex Matter, J. Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (M.L.); (L.C.)
| | - Dominik Brandl
- East Bavarian Centre for Intelligent Materials (EBACIM), Ostbayerische Technische Hochschule (OTH) Regensburg, Seybothstr. 2, 93053 Regensburg, Germany; (D.B.); (G.G.); (I.A.B.); (M.S.)
| | - Gašper Glavan
- East Bavarian Centre for Intelligent Materials (EBACIM), Ostbayerische Technische Hochschule (OTH) Regensburg, Seybothstr. 2, 93053 Regensburg, Germany; (D.B.); (G.G.); (I.A.B.); (M.S.)
| | - Inna A. Belyaeva
- East Bavarian Centre for Intelligent Materials (EBACIM), Ostbayerische Technische Hochschule (OTH) Regensburg, Seybothstr. 2, 93053 Regensburg, Germany; (D.B.); (G.G.); (I.A.B.); (M.S.)
| | - Luka Cmok
- Department of Complex Matter, J. Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (M.L.); (L.C.)
| | - Lucija Čoga
- Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva 6, 1000 Ljubljana, Slovenia; (L.Č.); (M.K.)
| | - Mitjan Kalin
- Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva 6, 1000 Ljubljana, Slovenia; (L.Č.); (M.K.)
| | - Mikhail Shamonin
- East Bavarian Centre for Intelligent Materials (EBACIM), Ostbayerische Technische Hochschule (OTH) Regensburg, Seybothstr. 2, 93053 Regensburg, Germany; (D.B.); (G.G.); (I.A.B.); (M.S.)
| | - Irena Drevenšek-Olenik
- Department of Complex Matter, J. Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (M.L.); (L.C.)
- Faculty of Mathematics and Physics, University of Ljubljana, Jadranska 19, 1000 Ljubljana, Slovenia
- Correspondence:
| |
Collapse
|
5
|
Wang S, Zhu Z, Ma C, Qiao R, Yang C, Xu RX, Si T. Generation of Nonspherical Liquid Metal Microparticles with Tunable Shapes Exhibiting an Electrostatic-Responsive Performance. ACS APPLIED MATERIALS & INTERFACES 2021; 13:16677-16687. [PMID: 33813828 DOI: 10.1021/acsami.1c01026] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Nonspherical liquid metal microparticles (NLMs) show extraordinary potential in various applications due to their multifunctional and structural advantages. To one-step-produce shaped NLMs with high efficiency, high controllability, and free of template, a facile microfluidic strategy named rotary flow shearing (RFS) is reported. A high-speed viscous shearing flow is provided by two counter-rotating rotors in the carrier fluid, inducing continuous pinch-off of liquid metal flowing from a capillary tube positioned in face of the slit between two rotors. The real-time oxidation realizes the rapid solidification of the pinching neck and the liquid metal surface during the RFS process, resulting in massive NLMs. Different from other microfluidic methods, the RFS enables tunable shapes of NLMs, especially for working materials at high viscosities. The collected NLMs exhibit special electrostatic-responsive performances including translation, rotation, reciprocation, and lining up under the manipulation of an external electric field. Such NLMs can be promisingly used for the construction of novel micromotors and soft electronics.
Collapse
Affiliation(s)
- Shiyu Wang
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230026, China
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, University of Science and Technology of China, Hefei 230026, China
| | - Zhiqiang Zhu
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230026, China
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, University of Science and Technology of China, Hefei 230026, China
| | - Canzhen Ma
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230026, China
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, University of Science and Technology of China, Hefei 230026, China
| | - Ran Qiao
- Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Chaoyu Yang
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230026, China
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, University of Science and Technology of China, Hefei 230026, China
| | - Ronald X Xu
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, United States
| | - Ting Si
- Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui 230026, China
| |
Collapse
|
6
|
Shu J, Lu Y, Wang E, Li X, Tang SY, Zhao S, Zhou X, Sun L, Li W, Zhang S. Particle-Based Porous Materials for the Rapid and Spontaneous Diffusion of Liquid Metals. ACS APPLIED MATERIALS & INTERFACES 2020; 12:11163-11170. [PMID: 32037788 DOI: 10.1021/acsami.9b20124] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Gallium-based room-temperature liquid metals have enormous potential for realizing various applications in electronic devices, heat flow management, and soft actuators. Filling narrow spaces with a liquid metal is of great importance in rapid prototyping and circuit printing. However, it is relatively difficult to stretch or spread liquid metals into desired patterns because of their large surface tension. Here, we propose a method to fabricate a particle-based porous material which can enable the rapid and spontaneous diffusion of liquid metals within the material under a capillary force. Remarkably, such a method can allow liquid metal to diffuse along complex structures and even overcome the effect of gravity despite their large densities. We further demonstrate that the developed method can be utilized for prototyping complex three-dimensional (3D) structures via direct casting and connecting individual parts or by 3D printing. As such, we believe that the presented technique holds great promise for the development of additive manufacturing, rapid prototyping, and soft electronics using liquid metals.
Collapse
Affiliation(s)
- Jian Shu
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Yangming Lu
- Robotics and Microsystems Center, School of Mechanical and Electric Engineering, Soochow University, Suzhou215000, China
| | - Erlong Wang
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Xiangpeng Li
- Robotics and Microsystems Center, School of Mechanical and Electric Engineering, Soochow University, Suzhou215000, China
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Changchun 130033, China
| | - Shi-Yang Tang
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong 2522, Australia
| | - Sizepeng Zhao
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Xiangbo Zhou
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Lining Sun
- Robotics and Microsystems Center, School of Mechanical and Electric Engineering, Soochow University, Suzhou215000, China
| | - Weihua Li
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong 2522, Australia
| | - Shiwu Zhang
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| |
Collapse
|
7
|
Numerical Simulation and Experimental Validation of Liquid Metal Droplet Formation in a Co-Flowing Capillary Microfluidic Device. MICROMACHINES 2020; 11:mi11020169. [PMID: 32033467 PMCID: PMC7074579 DOI: 10.3390/mi11020169] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Revised: 01/17/2020] [Accepted: 01/21/2020] [Indexed: 01/01/2023]
Abstract
A two-phase flow axisymmetric numerical model was proposed to understand liquid metal droplet formation in a co-flowing capillary microfluidics device based on a phase field model. The droplet detachment processes were observed in the experiment and are in good agreement with the simulation method. The effects of the viscosities and flowrates of the continuous phase fluid, interfacial tension as well as the wetting property of the metallic needle against the bulk liquid metal on the droplet formation and production rate were numerically investigated. It was found that the droplet diameter decreased with the increment of the viscosities and flowrates of the outer phase carrier fluid. The dispersed phase fluid with high interfacial tension tended to prolong the time for equilibrium between the viscous drag force and interfacial tension on the liquid–liquid fluid surface, delaying the droplet to be pinched off from the capillary orifice and causing large droplet diameter. Finally, the wetting performance of the metallic needle against the liquid metal was explored. The result indicate that the droplet diameter became less dependent on the contact angle while the size distribution of the liquid metal droplet was affected by their wetting performance. A more hydrophilic wetting performance were expected to prepare liquid metal droplet with more monodispersity. The numerical model and simulation results provide the feasibility of predicting the droplet formation with a high surface tension in a glass capillary microfluidic device.
Collapse
|
8
|
Tunable-Focus Liquid Lens through Charge Injection. MICROMACHINES 2020; 11:mi11010109. [PMID: 31968568 PMCID: PMC7019498 DOI: 10.3390/mi11010109] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Revised: 01/07/2020] [Accepted: 01/12/2020] [Indexed: 11/17/2022]
Abstract
Liquid lenses are the simplest and cheapest optical lenses, and various studies have been conducted to develop tunable-focus liquid lenses. In this study, a simple and easily implemented method for achieving tunable-focus liquid lenses was proposed and experimentally validated. In this method, charges induced by a corona discharge in the air were injected into dielectric liquid, resulting in “electropressure” at the interface between the air and the liquid. Through a 3D-printed U-tube structure, a tunable-focus liquid lens was fabricated and tested. Depending on the voltage, the focus of the liquid lens can be adjusted in large ranges (−∞ to −9 mm and 13.11 mm to ∞). The results will inspire various new liquid-lens applications.
Collapse
|
9
|
Lin P, Wei Z, Yan Q, Xie J, Fan Y, Wu M, Chen Y, Cheng Z. Capillary-Based Microfluidic Fabrication of Liquid Metal Microspheres toward Functional Microelectrodes and Photothermal Medium. ACS APPLIED MATERIALS & INTERFACES 2019; 11:25295-25305. [PMID: 31260237 DOI: 10.1021/acsami.9b03007] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Liquid metals (LMs) possess tremendous potential applications in flexible electronic devices, heat flow management, and smart actuators. Splitting the bulk LMs into microspheres is of great significance to fabricate free-standing and microscale LM-based functional materials and devices. However, it is difficult to disperse the bulk LMs into microspheres because of their large surface tension and high density. In this work, the capillary-based microfluidic chip is employed to continuously and automatically generate LM microspheres in a large scale. The capillary-based microfluidic fabrication is universally applicable in ionic aqueous solution, hydrophobic solution, and the polymeric aqueous solution. The precise size control of LM microspheres can be easily realized by the co-flowing configuration in the microchannels. The coefficient of size variation of monodispersed LM microspheres can be controlled to as low as 0.47%. The free-standing LM microspheres can be used as functional microelectrodes within a wide temperature range from -19.8 to 20 °C and to fabricate tunable integrated circuits with different output powers. Most importantly, the LM microspheres exhibit photothermal property, which is used to make the optical sensor with linear response and to conduct the solar energy harvesting. The capillary-based microfluidic fabrication of LM microspheres provides a facile and templated methodology for processing bulk LMs into microscale units. The LM microspheres with excellent electrical conductivity and photothermal property hold great promise for the development of miniature soft electronics, light-driven actuators, and energy conversion medium.
Collapse
Affiliation(s)
- Pengcheng Lin
- Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, School of Materials and Energy , Guangdong University of Technology , Guangzhou 510006 , China
| | - Zhan Wei
- Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, School of Materials and Energy , Guangdong University of Technology , Guangzhou 510006 , China
| | - Qi Yan
- Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, School of Materials and Energy , Guangdong University of Technology , Guangzhou 510006 , China
| | - Jiajin Xie
- Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, School of Materials and Energy , Guangdong University of Technology , Guangzhou 510006 , China
| | - Yufeng Fan
- Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, School of Materials and Energy , Guangdong University of Technology , Guangzhou 510006 , China
| | - Minghui Wu
- Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, School of Materials and Energy , Guangdong University of Technology , Guangzhou 510006 , China
| | - Ying Chen
- Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, School of Materials and Energy , Guangdong University of Technology , Guangzhou 510006 , China
| | - Zhengdong Cheng
- Artie McFerrin Department of Chemical Engineering , Texas A&M University , College Station , Texas 77843-3122 , United States
| |
Collapse
|
10
|
Tu X, Luo Y, Huang T, Gan J, Song C. Optofluidic refractive index sensor based on asymmetric diffraction. OPTICS EXPRESS 2019; 27:17809-17818. [PMID: 31252734 DOI: 10.1364/oe.27.017809] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Accepted: 05/29/2019] [Indexed: 06/09/2023]
Abstract
A novel optofluidic refracrtive index (RI) sensor was proposed based on asymmetric Fraunhofer diffraction. In-plane optofluidic lens, light source, slit, diffraction pattern visualization zone and optical path were integrated into the microfluidic networks to avoid the manual alignment of the optical components as well as to reduce the cost of external bulky components. Unlike the conventional RI sensor, this device visualizes the bulk refractive index change of the liquid through a diffraction image, which is readily read-out for clinical diagnosis right at the point-of-care or on-site security check. In the experiment, the device can measure a RI change of as low as ~10-5 RIU. A low noise-equivalent detection limit (NEDL) of ~10-6 refractive index unit (RIU) and high sensitivity of ~1.1 × 104/RIU were achieved. The new device is practical and suitable to be extended for high throughput applications by simultaneously reading multiple chips with an 2D-array image sensor.
Collapse
|
11
|
Jin T, Hadji EM, Zhao N, Duan Z, Wang J. Generation and Analysis of Axiolitic Liquid‐Metal Droplets in a T‐Junction Microfluidic Device. ChemistrySelect 2019. [DOI: 10.1002/slct.201803975] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Taoming Jin
- School of Chemical Engineering and TechnologyTianjin University Tianjin 300072 P.R. China
| | - Edward Mohamed Hadji
- School of Chemical Engineering and TechnologyTianjin University Tianjin 300072 P.R. China
| | - Na Zhao
- School of Chemical Engineering and TechnologyTianjin University Tianjin 300072 P.R. China
| | - Zhenya Duan
- College of Electromechanical EngineeringQingdao University of Science and Technology Qingdao 266061 P.R. China
| | - Jingtao Wang
- School of Chemical Engineering and TechnologyTianjin University Tianjin 300072 P.R. China
| |
Collapse
|
12
|
Hayat Z, El Abed AI. High-Throughput Optofluidic Acquisition of Microdroplets in Microfluidic Systems. MICROMACHINES 2018; 9:E183. [PMID: 30424116 PMCID: PMC6187520 DOI: 10.3390/mi9040183] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 03/26/2018] [Accepted: 04/04/2018] [Indexed: 12/24/2022]
Abstract
Droplet optofluidics technology aims at manipulating the tiny volume of fluids confined in micro-droplets with light, while exploiting their interaction to create "digital" micro-systems with highly significant scientific and technological interests. Manipulating droplets with light is particularly attractive since the latter provides wavelength and intensity tunability, as well as high temporal and spatial resolution. In this review study, we focus mainly on recent methods developed in order to monitor real-time analysis of droplet size and size distribution, active merging of microdroplets using light, or to use microdroplets as optical probes.
Collapse
Affiliation(s)
- Zain Hayat
- Laboratoire de Photonique Quantique et Moléculaire, UMR 8537, Ecole Normale Supérieure Paris Saclay, CentraleSupélec, CNRS, Université Paris-Saclay, 61 avenue du Président Wilson, 94235 Cachan, France.
| | - Abdel I El Abed
- Laboratoire de Photonique Quantique et Moléculaire, UMR 8537, Ecole Normale Supérieure Paris Saclay, CentraleSupélec, CNRS, Université Paris-Saclay, 61 avenue du Président Wilson, 94235 Cachan, France.
| |
Collapse
|
13
|
Zuo Y, Zhu X, Shi Y, Liang L, Yang Y. Light Manipulation in Inhomogeneous Liquid Flow and Its Application in Biochemical Sensing. MICROMACHINES 2018; 9:mi9040163. [PMID: 30424097 PMCID: PMC6187708 DOI: 10.3390/mi9040163] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 03/23/2018] [Accepted: 03/26/2018] [Indexed: 02/06/2023]
Abstract
Light manipulation has always been the fundamental subject in the field of optics since centuries ago. Traditional optical devices are usually designed using glasses and other materials, such as semiconductors and metals. Optofluidics is the combination of microfluidics and optics, which brings a host of new advantages to conventional solid systems. The capabilities of light manipulation and biochemical sensing are inherent alongside the emergence of optofluidics. This new research area promotes advancements in optics, biology, and chemistry. The development of fast, accurate, low-cost, and small-sized biochemical micro-sensors is an urgent demand for real-time monitoring. However, the fluid flow in the on-chip sensor is usually non-uniformed, which is a new and emerging challenge for the accuracy of optical detection. It is significant to reveal the principle of light propagation in an inhomogeneous liquid flow and the interaction between biochemical samples and light in flowing liquids. In this review, we summarize the current state of optofluidic lab-on-a-chip techniques from the perspective of light modulation by the unique dynamic properties of fluid in heterogeneous media, such as diffusion, heat transfer, and centrifugation etc. Furthermore, this review introduces several novel photonic phenomena in an inhomogeneous liquid flow and demonstrates their application in biochemical sensing.
Collapse
Affiliation(s)
- Yunfeng Zuo
- School of Physics and Technology, Wuhan University, Wuhan 430070, China.
| | - Xiaoqiang Zhu
- School of Physics and Technology, Wuhan University, Wuhan 430070, China.
| | - Yang Shi
- School of Physics and Technology, Wuhan University, Wuhan 430070, China.
| | - Li Liang
- School of Physics and Technology, Wuhan University, Wuhan 430070, China.
| | - Yi Yang
- School of Physics and Technology, Wuhan University, Wuhan 430070, China.
| |
Collapse
|
14
|
Chen Q, Li T, Zhu Y, Yu W, Zhang X. Dielectrophoresis-actuated in-plane optofluidic lens with tunability of focal length from negative to positive. OPTICS EXPRESS 2018; 26:6532-6541. [PMID: 29609341 DOI: 10.1364/oe.26.006532] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2017] [Accepted: 02/23/2018] [Indexed: 06/08/2023]
Abstract
This paper reports a tunable in-plane optofluidic lens by continuously tuning a silicone oil-air interface from concave to convex using the dielectrophoresis (DEP) force. Two parallel glasses are bonded firmly on two sides by NOA 81(Norland Optical Adhesive 81) spacers, forming an open microfluidic channel. An ITO (indium tin oxide) strip and another unpatterned ITO layer are deposited on two glasses as the top and bottom electrodes. Initially, a capillary concave liquid-air interface is formed at the end of the open channel. Then the DEP force is enabled to continuously deform the interface (lens) from concave to convex. In the experiment, the focal length gradually decreases from about -1 mm to infinite and then from infinite to around + 1 mm when the driving voltage is increased from 0 V to 260 V. Particularly, the longitudinal spherical aberration (LSA) is effectively suppressed to have LSA < 0.04 when the lens is operated in the focusing state. This work is the first study of in-plane tunable lenses using the DEP force and possesses special merits as compared to the other reported tunable lenses that are formed by pumping different liquids or by temperature gradient, such as wide tunability, no need for continuous supply of liquids, low power consumption (~81 nJ per switching) due to the capacitor-type driving, and the use of only one type of liquid. Besides, its low aberration makes it favorable for light manipulation in microfluidic networks.
Collapse
|
15
|
Abstract
In the recent past, the field of optofluidics has thrived from the immense efforts of researchers from diverse communities. The concept of optofluidics combines optics and microfluidics to exploit novel properties and functionalities. In the very beginning, the unique properties of liquid, such as mobility, fungibility and deformability, initiated the motivation to develop optical elements or functions using fluid interfaces. Later on, the advancements of microelectromechanical system (MEMS) and microfluidic technologies enabled the realization of optofluidic components through the precise manipulation of fluids at microscale thus making it possible to streamline complex fabrication processes. The optofluidic system aims to fully integrate optical functions on a single chip instead of using external bulky optics, which can consequently lower the cost of system, downsize the system and make it promising for point-of-care diagnosis. This perspective gives an overview of the recent developments in the field of optofluidics. Firstly, the fundamental optofluidic components will be discussed and are categorized according to their basic working mechanisms, followed by the discussions on the functional instrumentations of the optofluidic components, as well as the current commercialization aspects of optofluidics. The paper concludes with the critical challenges that might hamper the transformation of optofluidic technologies from lab-based procedures to practical usages and commercialization.
Collapse
|
16
|
Fang C, Dai B, Xu Q, Zhuo R, Wang Q, Wang X, Zhang D. Hydrodynamically reconfigurable optofluidic microlens with continuous shape tuning from biconvex to biconcave. OPTICS EXPRESS 2017; 25:888-897. [PMID: 28157977 DOI: 10.1364/oe.25.000888] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper presents an in-plane hydrodynamically reconfigurable optofluidic microlens, which is formed by the laminar flow of two streams of a low-refractive-index fluid and two streams of a high-refractive-index fluid in the two microchannels connecting to an expansion chamber where the microlens finally forms. In the expansion chamber, the stream of high-refractive-index fluid, acting as core, is sandwiched by the two streams of low-refractive-index fluid, acting as cladding. The interfaces between the streams can be flexibly manipulated by controlling the flow rate ratio between the two fluids in real time. Thus, the biconvex and biconcave microlens with different curvatures can be formed. By adjusting the microlens, the light beam can be continuously manipulated from focusing to collimation and then to divergence. In the experiment, a wide focus tuning range from 2.75 (focusing) to -1.21 mm (diverging) via collimation is achieved.
Collapse
|
17
|
Zhao HT, Yang Y, Chin LK, Chen HF, Zhu WM, Zhang JB, Yap PH, Liedberg B, Wang K, Wang G, Ser W, Liu AQ. Optofluidic lens with low spherical and low field curvature aberrations. LAB ON A CHIP 2016; 16:1617-24. [PMID: 27050492 DOI: 10.1039/c6lc00295a] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This paper reports an optofluidic lens with low spherical and low field curvature aberrations through the desired refractive index profile by precisely controlling the mixing between ethylene glycol and deionized water in an optofluidic chip. The experimental results demonstrate that the spherical aberration is reduced to 19.5 μm and the full width at half maximum of the focal point is 7.8 μm with a wide divergence angle of 35 degrees. In addition, the optofluidic lens can focus light at different off-axis positions on the focal plane with Δx' < 6.8 μm and at opposite transverse positions with |Δy - Δy'| < 5.7 μm. This is the first demonstration of a special optofluidic lens that significantly reduces both the spherical and field curvature aberrations, which enhances the focusing power and facilitates multiple light source illumination using a single lens. It is anticipated to have high potential for applications such as on-chip light manipulation, sample illumination and multiplexed detection.
Collapse
Affiliation(s)
- H T Zhao
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - Y Yang
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - L K Chin
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - H F Chen
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - W M Zhu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - J B Zhang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - P H Yap
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232
| | - B Liedberg
- Interdisciplinary Graduate School, Nanyang Technological University, Singapore 639798
| | - K Wang
- Institute of Biological Chemistry, Academia Sinica, Taipei 115, Taiwan and College of Medical Science and Technology, Taipei Medical University, Taipei 110, Taiwan
| | - G Wang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - W Ser
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - A Q Liu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| |
Collapse
|
18
|
Tang SY, Joshipura ID, Lin Y, Kalantar-Zadeh K, Mitchell A, Khoshmanesh K, Dickey MD. Liquid-Metal Microdroplets Formed Dynamically with Electrical Control of Size and Rate. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2016; 28:604-9. [PMID: 26601792 DOI: 10.1002/adma.201503875] [Citation(s) in RCA: 61] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2015] [Revised: 10/09/2015] [Indexed: 05/26/2023]
Abstract
Liquid metal co-injected with electrolyte through a microfluidic flow-focusing orifice forms droplets with diameters and production frequencies controlled in real time by voltage. Applying voltage to the liquid metal controls the interfacial tension via a combination of electrochemistry and electrocapillarity. This simple and effective method can instantaneously tune the size of the microdroplets, which has applications in composites, catalysts, and microsystems.
Collapse
Affiliation(s)
- Shi-Yang Tang
- School of Electrical and Computer Engineering, RMIT University, Melbourne, VIC 3001, Australia
| | - Ishan D Joshipura
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | - Yiliang Lin
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | - Kourosh Kalantar-Zadeh
- School of Electrical and Computer Engineering, RMIT University, Melbourne, VIC 3001, Australia
| | - Arnan Mitchell
- School of Electrical and Computer Engineering, RMIT University, Melbourne, VIC 3001, Australia
| | - Khashayar Khoshmanesh
- School of Electrical and Computer Engineering, RMIT University, Melbourne, VIC 3001, Australia
| | - Michael D Dickey
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
19
|
Yu JQ, Huang W, Chin LK, Lei L, Lin ZP, Ser W, Chen H, Ayi TC, Yap PH, Chen CH, Liu AQ. Droplet optofluidic imaging for λ-bacteriophage detection via co-culture with host cell Escherichia coli. LAB ON A CHIP 2014; 14:3519-24. [PMID: 25008551 DOI: 10.1039/c4lc00042k] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Bacteriophages are considered as attractive indicators for determining drinking water quality since its concentration is strongly correlated with virus concentrations in water samples. Previously, bacteriophage detection was based on a plague assay that required a complicated labelling technique and a time-consuming culture assay. Here, for the first time, a label-free bacteriophage detection is reported by using droplet optofluidic imaging, which uses host-cell-containing microdroplets as reaction carriers for bacteriophage infection due to a higher contact ratio. The optofluidic imaging is based on the effective refractive index changes in the microdroplet correlated with the growth rate of the infected host cells, which is highly sensitive, i.e. can detect one E. coli cell. The droplet optofluidic system is not only used in drinking water quality monitoring, but also has high potential applications for pathogenic bacteria detection in clinical diagnosis and food industry.
Collapse
Affiliation(s)
- J Q Yu
- School of Electrical & Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Abstract
Plasmonics provides an unparalleled method for manipulating light beyond the diffraction limit, making it a promising technology for the development of ultra-small, ultra-fast, power-efficient optical devices. To date, the majority of plasmonic devices are in the solid state and have limited tunability or configurability. Moreover, individual solid-state plasmonic devices lack the ability to deliver multiple functionalities. Here we utilize laser-induced surface bubbles on a metal film to demonstrate, for the first time, a plasmonic lens in a microfluidic environment. Our “plasmofluidic lens” device is dynamically tunable and reconfigurable. We record divergence, collimation, and focusing of surface plasmon polaritons using this device. The plasmofluidic lens requires no sophisticated nanofabrication and utilizes only a single low-cost diode laser. Our results show that the integration of plasmonics and microfluidics allows for new opportunities in developing complex plasmonic elements with multiple functionalities, high-sensitivity and high-throughput biomedical detection systems, as well as on-chip, all-optical information processing techniques.
Collapse
|
21
|
Yu JQ, Liu XF, Chin LK, Liu AQ, Luo KQ. Study of endothelial cell apoptosis using fluorescence resonance energy transfer (FRET) biosensor cell line with hemodynamic microfluidic chip system. LAB ON A CHIP 2013; 13:2693-2700. [PMID: 23620256 DOI: 10.1039/c3lc50105a] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
To better understand how hyperglycemia induces endothelial cell dysfunction under the diabetic conditions, a hemodynamic microfluidic chip system was developed. The system combines a caspase-3-based fluorescence resonance energy transfer (FRET) biosensor cell line which can detect endothelial cell apoptosis in real-time, post-treatment effect and with a limited cell sample, by using a microfluidic chip which can mimic the physiological pulsatile flow profile in the blood vessel. The caspase-3-based FRET biosensor endothelial cell line (HUVEC-C3) can produce a FRET-based sensor protein capable of probing caspase-3 activation. When the endothelial cells undergo apoptosis, the color of the sensor cells changes from green to blue, thus sensing apoptosis. A double-labeling fluorescent technique (yo pro-1 and propidium iodide) was used to validate the findings revealed by the FRET-based caspase sensor. The results show high rates of apoptosis and necrosis of endothelial cells when high glucose concentration was applied in our hemodynamic microfluidic chip combined with an exhaustive pulsatile flow profile. The two apoptosis detection techniques (fluorescent method and FRET biosensor) are comparable; but FRET biosensor offers more advantages such as real-time observation and a convenient operating process to generate more accurate and reliable data. Furthermore, the activation of the FRET biosensor also confirms the endothelial cell apoptosis induced by the abnormal pulsatile shear stress and high glucose concentration is through caspase-3 pathway. A 12% apoptotic rate (nearly a 4-fold increase compared to the static condition) was observed when the endothelial cells were exposed to a high glucose concentration of 20 mM under 2 h exhaustive pulsatile shear stress of 30 dyne cm(-2) and followed with another 10 h normal pulsatile shear stress of 15 dyne cm(-2). Therefore, the most important finding of this study is to develop a novel endothelial cell apoptosis detection method, which combines the microfluidic chip system and FRET biosensor. This finding may provide new insight into how glucose causes endothelial cell dysfunction, which is the major cause of diabetes-derived complications.
Collapse
Affiliation(s)
- J Q Yu
- School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798
| | | | | | | | | |
Collapse
|
22
|
Shen Z, Zou Y, Chen X. Characterization of microdroplets using optofluidic signals. LAB ON A CHIP 2012; 12:3816-3820. [PMID: 22885724 DOI: 10.1039/c2lc40758b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We develop a simple method to determine the microdroplet features in a microfluidic chip fabricated by conventional soft lithography. Different sizes of microdroplets are generated through a typical microfluidic T-junction by adjusting the flow rates of the two immiscible liquids. Droplet size and content can be determined by monitoring the optofluidic signals reflected at the fluid-polydimethylsiloxane (PDMS) interface. The demonstrated droplet characterization system can be readily integrated with other microfluidic networks, making it promising for biochemical and biosensing applications.
Collapse
Affiliation(s)
- Zhenhua Shen
- Department of Physics, State Key Laboratory on Fiber Optic Local Area Communication Networks and Advanced Optical Communication Systems, Shanghai Jiao Tong University, Shanghai, 200240, China
| | | | | |
Collapse
|
23
|
Li ZG, Ando K, Yu JQ, Liu AQ, Zhang JB, Ohl CD. Fast on-demand droplet fusion using transient cavitation bubbles. LAB ON A CHIP 2011; 11:1879-1885. [PMID: 21487578 DOI: 10.1039/c0lc00661k] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A method for on-demand droplet fusion in a microfluidic channel is presented using the flow created from a single explosively expanding cavitation bubble. We test the technique for water-in-oil droplets, which are produced using a T-junction design in a microfluidic chip. The cavitation bubble is created with a pulsed laser beam focused into one droplet. High-speed photography of the dynamics reveals that the droplet fusion can be induced within a few tens of microseconds and is caused by the rapid thinning of the continuous phase film separating the droplets. The cavitation bubble collapses and re-condenses into the droplet. Droplet fusion is demonstrated for static and moving droplets, and for droplets of equal and unequal sizes. Furthermore, we reveal the diffusion dominated mixing flow and the transport of a single encapsulated cell into a fused droplet. This laser-based droplet fusion technique may find applications in micro-droplet based chemical synthesis and bioassays.
Collapse
Affiliation(s)
- Z G Li
- Division of Microelectronics, School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, Singapore
| | | | | | | | | | | |
Collapse
|
24
|
Lapsley MI, Chiang IK, Zheng YB, Ding X, Mao X, Huang TJ. A single-layer, planar, optofluidic Mach-Zehnder interferometer for label-free detection. LAB ON A CHIP 2011; 11:1795-800. [PMID: 21479332 PMCID: PMC3998765 DOI: 10.1039/c0lc00707b] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
We have developed a planar, optofluidic Mach-Zehnder interferometer for the label-free detection of liquid samples. In contrast to most on-chip interferometers which require complex fabrication, our design was realized via a simple, single-layer soft lithography fabrication process. In addition, a single-wavelength laser source and a silicon photodetector were the only optical equipment used for data collection. The device was calibrated using published data for the refractive index of calcium chloride (CaCl(2)) in solution, and the biosensing capabilities of the device were tested by detecting bovine serum albumin (BSA). Our design enables a refractometer with a low limit of detection (1.24 × 10(-4) refractive index units (RIU)), low variability (1 × 10(-4) RIU), and high sensitivity (927.88 oscillations per RIU). This performance is comparable to state-of-the-art optofluidic refractometers that involve complex fabrication processes and/or expensive, bulky optics. The advantages of our device (i.e. simple fabrication process, straightforward optical equipment, low cost, and high detection sensitivity) make it a promising candidate for future mass-producible, inexpensive, highly sensitive, label-free optical detection systems.
Collapse
Affiliation(s)
- Michael Ian Lapsley
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
| | - I.-Kao Chiang
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
| | - Yue Bing Zheng
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
| | - Xiaoyun Ding
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
| | - Xiaole Mao
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
- Department of Bioengineering, Pennsylvania State University, University Park, PA, 16802, USA
| | - Tony Jun Huang
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
- Department of Bioengineering, Pennsylvania State University, University Park, PA, 16802, USA
| |
Collapse
|
25
|
Zhang K, Jian A, Zhang X, Wang Y, Li Z, Tam HY. Laser-induced thermal bubbles for microfluidic applications. LAB ON A CHIP 2011; 11:1389-95. [PMID: 21331412 DOI: 10.1039/c0lc00520g] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We present a unique bubble generation technique in microfluidic chips using continuous-wave laser-induced heat and demonstrate its application by creating micro-valves and micro-pumps. In this work, efficient generation of thermal bubbles of controllable sizes has been achieved using different geometries of chromium pads immersed in various types of fluid. Effective blocking of microfluidic channels (cross-section 500 × 40 μm(2)) and direct pumping of fluid at a flow rate of 7.2-28.8 μl h(-1) with selectable direction have also been demonstrated. A particular advantage of this technique is that it allows the generation of bubbles at almost any location in the microchannel and thus enables microfluidic control at any point of interest. It can be readily integrated into lab-on-a-chip systems to improve functionality.
Collapse
Affiliation(s)
- Kai Zhang
- Department of Applied Physics and Materials Research Center, The Hong Kong Polytechnic University, Hong Kong, People's Republic of China
| | | | | | | | | | | |
Collapse
|
26
|
Fan SK, Chiu CP, Huang PW. Transmittance tuning by particle chain polarization in electrowetting-driven droplets. BIOMICROFLUIDICS 2010; 4:43011. [PMID: 21267088 PMCID: PMC3026033 DOI: 10.1063/1.3516656] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2010] [Accepted: 10/23/2010] [Indexed: 05/14/2023]
Abstract
A tiny droplet containing nano∕microparticles commonly handled in digital microfluidic lab-on-a-chip is regarded as a micro-optical component with tunable transmittance at programmable positions for the application of micro-opto-fluidic-systems. Cross-scale electric manipulations of droplets on a millimeter scale as well as suspended particles on a micrometer scale are demonstrated by electrowetting-on-dielectric (EWOD) and particle chain polarization, respectively. By applying electric fields at proper frequency ranges, EWOD and polarization can be selectively achieved in designed and fabricated parallel plate devices. At low frequencies, the applied signal generates EWOD to pump suspension droplets. The evenly dispersed particles reflect and∕or absorb the incident light to exhibit a reflective or dark droplet. When sufficiently high frequencies are used on to the nonsegmented parallel electrodes, a uniform electric field is established across the liquid to polarize the dispersed neutral particles. The induced dipole moments attract the particles each other to form particle chains and increase the transmittance of the suspension, demonstrating a transmissive or bright droplet. In addition, the reflectance of the droplet is measured at various frequencies with different amplitudes.
Collapse
Affiliation(s)
- Shih-Kang Fan
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu 300, Taiwan
| | | | | |
Collapse
|