1
|
Shan S, Zhao X, Wood-Trageser MA, Hu D, Liu L, Qi B, Jian J, Wang P, Lv W, Hu C. Obliteration of portal venules contributes to portal hypertension in biliary cirrhosis. J Pathol 2024; 263:178-189. [PMID: 38551075 DOI: 10.1002/path.6273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 01/05/2024] [Accepted: 02/13/2024] [Indexed: 05/12/2024]
Abstract
The effects of the obliteration of portal venules (OPV) in cirrhotic portal hypertension are poorly understood. To investigate its contribution to portal hypertension in biliary cirrhosis and its underlying mechanism, we evaluated OPV using two-dimensional (2D) histopathology in liver explants from patients with biliary atresia (BA, n = 63), primary biliary cholangitis (PBC, n = 18), and hepatitis B-related cirrhosis (Hep-B-cirrhosis, n = 35). Then, three-dimensional (3D) OPV was measured by X-ray phase-contrast CT in two parallel models in rats following bile duct ligation (BDL) or carbon tetrachloride (CCl4) administration, representing biliary cirrhosis and post-necrotic cirrhosis, respectively. The portal pressure was also measured in the two models. Finally, the effects of proliferative bile ducts on OPV were investigated. We found that OPV was significantly more frequent in patients with biliary cirrhosis, including BA (78.57 ± 16.45%) and PBC (60.00 ± 17.15%), than that in Hep-B-cirrhotic patients (29.43 ± 14.94%, p < 0.001). OPV occurred earlier, evidenced by the paired liver biopsy at a Kasai procedure (KP), and was irreversible even after a successful KP in the patients with BA. OPV was also significantly more frequent in the BDL models than in the CCl4 models, as shown by 2D and 3D quantitative analysis. Portal pressure was significantly higher in the BDL model than that in the CCl4 model. With the proliferation of bile ducts, portal venules were compressed and irreversibly occluded, contributing to the earlier and higher portal pressure in biliary cirrhosis. OPV, as a pre-sinusoidal component, plays a key role in the pathogenesis of portal hypertension in biliary cirrhosis. The proliferated bile ducts and ductules gradually take up the 'territory' originally attributed to portal venules and compress the portal venules, which may lead to OPV in biliary cirrhosis. © 2024 The Pathological Society of Great Britain and Ireland.
Collapse
Affiliation(s)
- Shan Shan
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing, PR China
- Beijing Key Laboratory of Translational Medicine in Liver Cirrhosis and National Clinical Research Center of Digestive Disease, Beijing, PR China
| | - Xinyan Zhao
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing, PR China
- Beijing Key Laboratory of Translational Medicine in Liver Cirrhosis and National Clinical Research Center of Digestive Disease, Beijing, PR China
| | | | - Doudou Hu
- The Second Department of Gastroenterology, Qingdao Municipal Hospital, Qingdao, Shandong, PR China
| | - Liwei Liu
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing, PR China
| | - Beining Qi
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, PR China
| | - Jianbo Jian
- Department of Radiation Oncology, Tianjin Medical University General Hospital, Tianjin, PR China
| | - Ping Wang
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing, PR China
| | - Wenjuan Lv
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, PR China
| | - Chunhong Hu
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, PR China
| |
Collapse
|
2
|
Agrawal AK, Gupta C, Singh B, Kashyap Y, Shukla M. Quantitative phase contrast X-ray tomography of aluminium metal matrix composite. Appl Radiat Isot 2024; 204:111149. [PMID: 38134854 DOI: 10.1016/j.apradiso.2023.111149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 12/11/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
The quantitative assessment of micro-structure and load-induced damages in Al-SiC metal matrix composites (MMC) is important for its design optimization, performance evaluation and structure-property correlation. X-ray Phase contrast micro-tomography is potentially used for evaluation of its 3 dimensional micro-structure manifested in the form of voids, cracks, embedded particles, and load-induced damages. However, the contrast between Al matrix and SiC particles is insufficient for their clear morphological identification and quantitative assessment. In the present study, we have proposed and applied single image-based phase retrieval as a pre-processing step to micro-tomography reconstruction for improved assessment of micro-structure and cohesion-induced damages in Al-SiC MMC. The advantages of applying different phase retrieval techniques in the enhancement of image quality and morphological quantification of SiC particles, pores and cohesion damages are discussed. It is observed that the Paganin method offers the best improvement in contrast to noise ratio for the measurement of SiC particles embedded in the Al matrix.
Collapse
Affiliation(s)
- Ashish K Agrawal
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai, India; Homi Bhabha National Institute, Mumbai, 400 094, India.
| | - Chiradeep Gupta
- Mechanical Metallurgy Division, Bhabha Atomic Research Centre, Mumbai, India; Homi Bhabha National Institute, Mumbai, 400 094, India
| | - Balwant Singh
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai, India; Homi Bhabha National Institute, Mumbai, 400 094, India
| | - Yogesh Kashyap
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai, India; Homi Bhabha National Institute, Mumbai, 400 094, India
| | - Mayank Shukla
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai, India; Homi Bhabha National Institute, Mumbai, 400 094, India
| |
Collapse
|
3
|
Yu F, Du K, Ju X, Wang F, Li K, Chen C, Du G, Deng B, Xie H, Xiao T. Dynamic X-ray speckle-tracking imaging with high-accuracy phase retrieval based on deep learning. IUCRJ 2024; 11:73-81. [PMID: 38096037 PMCID: PMC10833393 DOI: 10.1107/s2052252523010114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 11/22/2023] [Indexed: 01/10/2024]
Abstract
Speckle-tracking X-ray imaging is an attractive candidate for dynamic X-ray imaging owing to its flexible setup and simultaneous yields of phase, transmission and scattering images. However, traditional speckle-tracking imaging methods suffer from phase distortion at locations with abrupt changes in density, which is always the case for real samples, limiting the applications of the speckle-tracking X-ray imaging method. In this paper, we report a deep-learning based method which can achieve dynamic X-ray speckle-tracking imaging with high-accuracy phase retrieval. The calibration results of a phantom show that the profile of the retrieved phase is highly consistent with the theoretical one. Experiments of polyurethane foaming demonstrated that the proposed method revealed the evolution of the complicated microstructure of the bubbles accurately. The proposed method is a promising solution for dynamic X-ray imaging with high-accuracy phase retrieval, and has extensive applications in metrology and quantitative analysis of dynamics in material science, physics, chemistry and biomedicine.
Collapse
Affiliation(s)
- Fucheng Yu
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People’s Republic of China
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Kang Du
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People’s Republic of China
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Xiaolu Ju
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People’s Republic of China
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Feixiang Wang
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
| | - Ke Li
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
| | - Can Chen
- Zhejiang Institute of Metrology, Hangzhou 310063, People’s Republic of China
| | - Guohao Du
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
| | - Biao Deng
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
| | - Honglan Xie
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
| | - Tiqiao Xiao
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People’s Republic of China
- Shanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| |
Collapse
|
4
|
Guo Z, Li C, Cao Y, Jiang L, Zhang Y, Li P, Zhou Y, Duan C, Hu J, Lu H. 3D visualization and morphometric analysis of spinal motion segments and vascular networks: A synchrotron radiation-based micro-CT study in mice. J Anat 2022; 240:268-278. [PMID: 34622448 PMCID: PMC8742973 DOI: 10.1111/joa.13556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 08/08/2021] [Accepted: 09/14/2021] [Indexed: 11/28/2022] Open
Abstract
The structure of spinal motion segments and spinal vasculature is complicated. Visualizing the three-dimensional (3D) structure of the spine may provide guidance for spine surgery. However, conventional imaging techniques fail to simultaneously obtain 3D images of soft and hard tissues, and achieving such coimaging states of the spine and its vascular networks remains a challenge. Synchrotron radiation micro-CT (SRμCT) provides a relatively effective and novel method of acquiring detailed 3D information. In this study, specimens of the thoracic spine were obtained from six mice. SRμCT was employed to acquire 3D images of the structure, and histologic staining was performed for comparisons with the SRμCT images. The whole spinal motion segments and the spinal vascular network were simultaneously explored at high resolution. The mean thickness of the cartilaginous end plates (CEPs) and the volume of the intervertebral discs (IVDs) were calculated. The surface of the CEPs and the facet joint cartilage (FJC) were presented as heat maps, which allowed for direct visualization of the thickness distribution. Regional division revealed heterogeneity among the ventral, central, and dorsal parts of the CEPs and between the superior and inferior parts of the facet processes. Moreover, the connections and spatial morphology of the spinal vascular network were visualized. Our study indicates that SRμCT imaging is an ideal method for high-resolution visualization and 3D morphometric analysis of the whole spinal motion segments and spinal vascular network.
Collapse
Affiliation(s)
- Zhu Guo
- Department of Spine Surgery and OrthopaedicsXiangya HospitalCentral South UniversityChangshaChina
- Spine Surgery Department of the Affiliated Hospital of Qingdao UniversityQingdaoChina
| | - Chengjun Li
- Department of Spine Surgery and OrthopaedicsXiangya HospitalCentral South UniversityChangshaChina
- National Clinical Research Center for Geriatric DisordersXiangya HospitalCentral South UniversityChangshaChina
- Key Laboratory of Organ Injury, Aging and Regenerative Medicine of Hunan ProvinceChangshaChina
| | - Yong Cao
- Department of Spine Surgery and OrthopaedicsXiangya HospitalCentral South UniversityChangshaChina
- National Clinical Research Center for Geriatric DisordersXiangya HospitalCentral South UniversityChangshaChina
- Key Laboratory of Organ Injury, Aging and Regenerative Medicine of Hunan ProvinceChangshaChina
| | - Liyuan Jiang
- Department of Spine Surgery and OrthopaedicsXiangya HospitalCentral South UniversityChangshaChina
- National Clinical Research Center for Geriatric DisordersXiangya HospitalCentral South UniversityChangshaChina
- Key Laboratory of Organ Injury, Aging and Regenerative Medicine of Hunan ProvinceChangshaChina
| | - Yi Zhang
- Department of Sports MedicineAffiliated Hospital of Qingdao UniversityQingdaoChina
- Traumatic Orthopaedic Institute of Shandong ProvinceAffiliated Hospital of Qingdao UniversityQingdaoChina
| | - Ping Li
- Department of ObstetricsXiangya HospitalCentral South UniversityChangshaChina
| | - Yongchun Zhou
- Department of OrthopedicShanxi Provincial People’s HospitalXi’anChina
| | - Chunyue Duan
- Department of Spine Surgery and OrthopaedicsXiangya HospitalCentral South UniversityChangshaChina
- National Clinical Research Center for Geriatric DisordersXiangya HospitalCentral South UniversityChangshaChina
| | - Jianzhong Hu
- Department of Spine Surgery and OrthopaedicsXiangya HospitalCentral South UniversityChangshaChina
- National Clinical Research Center for Geriatric DisordersXiangya HospitalCentral South UniversityChangshaChina
- Key Laboratory of Organ Injury, Aging and Regenerative Medicine of Hunan ProvinceChangshaChina
| | - Hongbin Lu
- Key Laboratory of Organ Injury, Aging and Regenerative Medicine of Hunan ProvinceChangshaChina
- Department of Sports MedicineResearch Centre of Sports MedicineXiangya HospitalCentral South UniversityChangshaChina
| |
Collapse
|
5
|
X-ray dark-field phase-contrast imaging: Origins of the concept to practical implementation and applications. Phys Med 2020; 79:188-208. [PMID: 33342666 DOI: 10.1016/j.ejmp.2020.11.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Revised: 11/13/2020] [Accepted: 11/26/2020] [Indexed: 12/18/2022] Open
Abstract
The basic idea of X-ray dark-field imaging (XDFI), first presented in 2000, was based on the concepts used in an X-ray interferometer. In this article, we review 20 years of developments in our theoretical understanding, scientific instrumentation, and experimental demonstration of XDFI and its applications to medical imaging. We first describe the concepts underlying XDFI that are responsible for imparting phase contrast information in projection X-ray images. We then review the algorithms that can convert these projection phase images into three-dimensional tomographic slices. Various implementations of computed tomography reconstructions algorithms for XDFI data are discussed. The next four sections describe and illustrate potential applications of XDFI in pathology, musculoskeletal imaging, oncologic imaging, and neuroimaging. The sample applications that are presented illustrate potential use scenarios for XDFI in histopathology and other clinical applications. Finally, the last section presents future perspectives and potential technical developments that can make XDFI an even more powerful tool.
Collapse
|
6
|
Zhang L, Zhao H, Jiang J, Zhang L, Li J, Gao F, Zhou Z. Investigation on the Dependency of Phase Retrieval Accuracy Versus Edge Enhancement to the Noise Ratio of X-ray Propagation-Based Phase-Contrast Imaging. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2019; 25:1201-1212. [PMID: 31407647 DOI: 10.1017/s1431927619014764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Phase retrieval is necessary for propagation-based phase-contrast imaging (PB-PCI). Arhatari established a model for predicting the impact of the sample-to-detector distance and the system noise on the phase retrieval performance. We have extended Arhatari's model to account for the parameters of excessive source size, finite detector resolution, and geometrical magnification for more practical cases. However, there exist interaction effects among these parameters resulting in difficulty of predicting the phase retrieval performance. In this study, we found that optimizing the trade-off among these parameters for phase retrieval is consistent with the improvement of edge enhancement to noise ratio (EE/N) in the "forward problem" of the PB-PCI. Hence, we engaged in establishing a relationship between EE/N and phase retrieval performance in terms of the "forward problem" and "inverse problem" of the PB-PCI, respectively. Our results showed that, at fixed detector resolution, phase retrieval from the phase-contrast projections at the same EE/N level resulted in the consistent phase retrieval performance. Therefore, the performance of phase retrieval can be predicted based on the EE/N level and be quantitatively optimized by increasing EE/N.
Collapse
Affiliation(s)
- Lin Zhang
- School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, People's Republic of China
| | - Huijuan Zhao
- School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, People's Republic of China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, People's Republic of China
| | - Jingying Jiang
- Beijing Advanced Innovation Centre for Big Data-based Precision Medicine, Beihang University, Beijing 100191, China
| | - Limin Zhang
- School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, People's Republic of China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, People's Republic of China
| | - Jiao Li
- School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, People's Republic of China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, People's Republic of China
| | - Feng Gao
- School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, People's Republic of China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, People's Republic of China
| | - Zhongxing Zhou
- School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, People's Republic of China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, People's Republic of China
- Tianjin Shareshine Technology Development Co, Ltd., Tianjin, People's Republic of China
- Tianjin Key Laboratory in Environmental Monitoring Techniques, Tianjin, People's Republic of China
| |
Collapse
|
7
|
Ghani MU, Gregory B, Omoumi F, Zheng B, Yan A, Wu X, Liu H. Impact of a single distance phase retrieval algorithm on spatial resolution in X-ray inline phase sensitive imaging. BIOMEDICAL SPECTROSCOPY AND IMAGING 2019; 8:29-40. [PMID: 31788419 PMCID: PMC6883648 DOI: 10.3233/bsi-190186] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
A single-projection based phase retrieval method based on the phase attenuation duality principle (PAD) was used to compare the spatial resolution of the acquired phase sensitive and PAD processed phase retrieved images. An inline phase sensitive prototype was used to acquire the phase sensitive images. The prototype incorporates a micro-focus x-ray source and a flat panel detector with a 50 μm pixel pitch. A phantom composed of a 2 cm thick 50-50 adipose-glandular mimicking slab sandwiched with a 0.82 cm thick slanted PMMA sharp edge was used. Phase sensitive image of the phantom was acquired at 120 kV, 3.35 mAs with a 16 μm tube focal spot size under a geometric magnification (M) of 2.5. The PAD based method was applied to the acquired phase sensitive image for the retrieval of phase values. With necessary data processing, modulation transfer function (MTF) curves were determined for the estimation and comparison of the spatial resolution. The PAD processed phase retrieved values of the phantom were in good agreement with the theoretically calculated values. Phase sensitive images showed higher spatial resolution at all spatial frequencies compared to the phase retrieved images. It was noted that the high-frequency signal components in the retrieved image were suppressed that resulted in lower MTF values. When compared to the phase sensitive image, the cutoff resolution (10% MTF) for phase retrieved image dropped 32% from 15.6 lp/mm (32μm) to 10.6 lp/mm (47μm). The resolution offered by this phase sensitive prototype is radiographically enough to detect breast cancer.
Collapse
Affiliation(s)
- Muhammad. U. Ghani
- Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma,
Norman, OK 73019, USA
| | - Bradley Gregory
- Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma,
Norman, OK 73019, USA
| | - Farid Omoumi
- Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma,
Norman, OK 73019, USA
| | - Bin Zheng
- Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma,
Norman, OK 73019, USA
| | - Aimin Yan
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, 35249, USA
| | - Xizeng Wu
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, 35249, USA
| | - Hong Liu
- Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma,
Norman, OK 73019, USA
| |
Collapse
|
8
|
Brun F, Brombal L, Di Trapani V, Delogu P, Donato S, Dreossi D, Rigon L, Longo R. Post-reconstruction 3D single-distance phase retrieval for multi-stage phase-contrast tomography with photon-counting detectors. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:510-516. [PMID: 30855262 DOI: 10.1107/s1600577519000237] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 01/05/2019] [Indexed: 06/09/2023]
Abstract
In the case of single-distance propagation-based phase-contrast X-ray computed tomography with synchrotron radiation, the conventional reconstruction pipeline includes an independent 2D phase retrieval filtering of each acquired projection prior to the actual reconstruction. In order to compensate for the limited height of the X-ray beam or the small sensitive area of most modern X-ray photon-counting detectors, it is quite common to image large objects with a multi-stage approach, i.e. several acquisitions at different vertical positions of the sample. In this context, the conventional reconstruction pipeline may introduce artifacts at the margins of each vertical stage. This article presents a modified computational protocol where a post-reconstruction 3D volume phase retrieval is applied. By comparing the conventional 2D and the proposed 3D reconstructions of a large mastectomy specimen (9 cm in diameter and 3 cm in height), it is here shown that the 3D approach compensates for the multi-stage artifacts, it avoids refined projection stitching, and the image quality in terms of spatial resolution, contrast and contrast-to-noise ratio is preserved.
Collapse
Affiliation(s)
- Francesco Brun
- National Institute for Nuclear Physics (INFN) - Trieste Division, Italy
| | - Luca Brombal
- National Institute for Nuclear Physics (INFN) - Trieste Division, Italy
| | - Vittorio Di Trapani
- Department of Physical Sciences, Earth and Environment, University of Siena, Italy
| | - Pasquale Delogu
- Department of Physical Sciences, Earth and Environment, University of Siena, Italy
| | - Sandro Donato
- National Institute for Nuclear Physics (INFN) - Trieste Division, Italy
| | | | - Luigi Rigon
- National Institute for Nuclear Physics (INFN) - Trieste Division, Italy
| | - Renata Longo
- National Institute for Nuclear Physics (INFN) - Trieste Division, Italy
| |
Collapse
|
9
|
Luo Y, Yin X, Shi S, Ren X, Zhang H, Wang Z, Cao Y, Tang M, Xiao B, Zhang M. Non-destructive 3D Microtomography of Cerebral Angioarchitecture Changes Following Ischemic Stroke in Rats Using Synchrotron Radiation. Front Neuroanat 2019; 13:5. [PMID: 30766481 PMCID: PMC6365468 DOI: 10.3389/fnana.2019.00005] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 01/15/2019] [Indexed: 01/29/2023] Open
Abstract
A better understanding of functional changes in the cerebral microvasculature following ischemic injury is essential to elucidate the pathogenesis of stroke. Up to now, the simultaneous depiction and stereological analysis of 3D micro-architectural changes of brain vasculature with network disorders remains a technical challenge. We aimed to explore the three dimensional (3D) microstructural changes of microvasculature in the rat brain on 4, 6 hours, 3 and 18 days post-ischemia using synchrotron radiation micro-computed tomography (SRμCT) with a per pixel size of 5.2 μm. The plasticity of angioarchitecture was distinctly visualized. Quantitative assessments of time-related trends after focal ischemia, including number of branches, number of nodes, and frequency distribution of vessel diameter, reached a peak at 6 h and significantly decreased at 3 days and initiated to form cavities. The detected pathological changes were also proven by histological tests. We depicted a novel methodology for the 3D analysis of vascular repair in ischemic injury, both qualitatively and quantitatively. Cerebral angioarchitecture sustained 3D remodeling and modification during the healing process. The results might provide a deeper insight into the compensatory mechanisms of microvasculature after injury, suggesting that SRμCT is able to provide a potential new platform for deepening imaging pathological changes in complicated angioarchitecture and evaluating potential therapeutic targets for stroke.
Collapse
Affiliation(s)
- Yonghong Luo
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, China
| | - Xianzhen Yin
- Center for Drug Delivery System, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, China
| | - Shupeng Shi
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, China
| | - Xiaolei Ren
- Department of Orthopaedics, Second Xiangya Hospital, Central South University, Changsha, China
| | - Haoran Zhang
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, China
| | - Zhuolu Wang
- Department of Breast Surgery, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China.,Department of General Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - Yong Cao
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - Mimi Tang
- Department of Pharmacy, Xiangya Hospital, Central South University, Changsha, China.,Institute of Hospital Pharmacy, Xiangya Hospital, Central South University, Changsha, China
| | - Bo Xiao
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, China
| | - Mengqi Zhang
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
10
|
Liu H, Ji X, Ma Y, Du G, Fu Y, Abudureheman Y, Liu W. Quantitative characterization and diagnosis via hard X-ray phase-contrast microtomography. Microsc Res Tech 2018; 81:1173-1181. [PMID: 30238563 DOI: 10.1002/jemt.23114] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 05/31/2018] [Accepted: 06/19/2018] [Indexed: 11/08/2022]
Abstract
Nondestructive three-dimensional (3D) micromorphological imaging technique is essential for hepatic alveolar echinococcosis (HAE) disease to determine its damage level and early diagnosis, assess relative drug therapy and optimize treatment strategies. However, the existing morphological researches of HAE mainly depend on the conventional CT, MRI, or ultrasound in hospitals, unfortunately confronting with the common limit of imaging resolution and sensitivity, especially for tiny or early HAE lesions. Now we presented a phase-retrieval-based synchrotron X-ray phase computed tomography (PR-XPCT) with striking contrast-to-noise ratio and high-density resolution to visualize the HAE nondestructive 3D structures and quantitatively segment different pathological characteristics of HAE lesions without staining process at the micrometer scale. Our experimental results of the HAE rat models at early and developed pathological stages and albendazole liposome (L-ABZ) therapeutic feeding models successfully exhibited the different HAE pathological 3D morphological and microstructural characteristics with excellent contrast and high resolution, demonstrating its availability and superiority. Moreover, we achieved the quantitative statistics and analysis of the pathological changes of HAE lesions at different stages and L-ABZ therapeutic evaluation, helpful to understanding the development and drug treatment of HAE disease. The PR-XPCT-based quantitative segmentation and characterization has a great potential in detection and analysis of soft tissue pathological changes, such as different tumors.
Collapse
Affiliation(s)
- Huiqiang Liu
- College of Medical Engineering and Technology, Xinjiang Medical University, China
| | - Xuewen Ji
- Hepatobiliary Surgery, First Affiliated Hospital, Xinjiang Medical University, China
| | - Yan Ma
- College of Medical Engineering and Technology, Xinjiang Medical University, China
| | - Guohao Du
- SSRF, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
| | - Yanan Fu
- SSRF, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
| | - Yibanu Abudureheman
- Imaging Center, First Affiliated Hospital, Xinjiang Medical University, China
| | - Wenya Liu
- Imaging Center, First Affiliated Hospital, Xinjiang Medical University, China
| |
Collapse
|
11
|
Identification of ginseng root using quantitative X-ray microtomography. J Ginseng Res 2017; 41:290-297. [PMID: 28701869 PMCID: PMC5489746 DOI: 10.1016/j.jgr.2016.05.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2014] [Revised: 05/16/2016] [Accepted: 05/31/2016] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND The use of X-ray phase-contrast microtomography for the investigation of Chinese medicinal materials is advantageous for its nondestructive, in situ, and three-dimensional quantitative imaging properties. METHODS The X-ray phase-contrast microtomography quantitative imaging method was used to investigate the microstructure of ginseng, and the phase-retrieval method is also employed to process the experimental data. Four different ginseng samples were collected and investigated; these were classified according to their species, production area, and sample growth pattern. RESULTS The quantitative internal characteristic microstructures of ginseng were extracted successfully. The size and position distributions of the calcium oxalate cluster crystals (COCCs), important secondary metabolites that accumulate in ginseng, are revealed by the three-dimensional quantitative imaging method. The volume and amount of the COCCs in different species of the ginseng are obtained by a quantitative analysis of the three-dimensional microstructures, which shows obvious difference among the four species of ginseng. CONCLUSION This study is the first to provide evidence of the distribution characteristics of COCCs to identify four types of ginseng, with regard to species authentication and age identification, by X-ray phase-contrast microtomography quantitative imaging. This method is also expected to reveal important relationships between COCCs and the occurrence of the effective medicinal components of ginseng.
Collapse
|
12
|
Liu H, Wu X, Xiao T. Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research. Med Phys 2016; 42:5595-603. [PMID: 26429234 DOI: 10.1118/1.4929551] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Propagation-based phase-contrast CT (PPCT) utilizes highly sensitive phase-contrast technology applied to x-ray microtomography. Performing phase retrieval on the acquired angular projections can enhance image contrast and enable quantitative imaging. In this work, the authors demonstrate the validity and advantages of a novel technique for high-resolution PPCT by using the generalized phase-attenuation duality (PAD) method of phase retrieval. METHODS A high-resolution angular projection data set of a fish head specimen was acquired with a monochromatic 60-keV x-ray beam. In one approach, the projection data were directly used for tomographic reconstruction. In two other approaches, the projection data were preprocessed by phase retrieval based on either the linearized PAD method or the generalized PAD method. The reconstructed images from all three approaches were then compared in terms of tissue contrast-to-noise ratio and spatial resolution. RESULTS The authors' experimental results demonstrated the validity of the PPCT technique based on the generalized PAD-based method. In addition, the results show that the authors' technique is superior to the direct PPCT technique as well as the linearized PAD-based PPCT technique in terms of their relative capabilities for tissue discrimination and characterization. CONCLUSIONS This novel PPCT technique demonstrates great potential for biomedical imaging, especially for applications that require high spatial resolution and limited radiation exposure.
Collapse
Affiliation(s)
- Huiqiang Liu
- Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan
| | - Xizeng Wu
- Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama 35249
| | - Tiqiao Xiao
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
| |
Collapse
|
13
|
Hofmann R, Schober A, Hahn S, Moosmann J, Kashef J, Hertel M, Weinhardt V, Hänschke D, Helfen L, Sánchez Salazar IA, Guigay JP, Xiao X, Baumbach T. Gauging low-dose X-ray phase-contrast imaging at a single and large propagation distance. OPTICS EXPRESS 2016; 24:4331-4348. [PMID: 26907079 DOI: 10.1364/oe.24.004331] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The interactions of a beam of hard and spatio-temporally coherent X-rays with a soft-matter sample primarily induce a transverse distribution of exit phase variations δϕ (retardations or advancements in pieces of the wave front exiting the object compared to the incoming wave front) whose free-space propagation over a distance z gives rise to intensity contrast gz. For single-distance image detection and |δϕ| ≪ 1 all-order-in-z phase-intensity contrast transfer is linear in δϕ. Here we show that ideal coherence implies a decay of the (shot-)noise-to-signal ratio in gz and of the associated phase noise as z(-1/2) and z(-1), respectively. Limits on X-ray dose thus favor large values of z. We discuss how a phase-scaling symmetry, exact in the limit δϕ → 0 and dynamically unbroken up to |δϕ| ∼ 1, suggests a filtering of gz in Fourier space, preserving non-iterative quasi-linear phase retrieval for phase variations up to order unity if induced by multi-scale objects inducing phase variations δϕ of a broad spatial frequency spectrum. Such an approach continues to be applicable under an assumed phase-attenuation duality. Using synchrotron radiation, ex and in vivo microtomography on frog embryos exemplifies improved resolution compared to a conventional single-distance phase-retrieval algorithm.
Collapse
|
14
|
High-Resolution and Quantitative X-Ray Phase-Contrast Tomography for Mouse Brain Research. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2015; 2015:530580. [PMID: 26576198 PMCID: PMC4630379 DOI: 10.1155/2015/530580] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2015] [Accepted: 08/17/2015] [Indexed: 11/18/2022]
Abstract
Imaging techniques for visualizing cerebral vasculature and distinguishing functional areas are essential and critical to the study of various brain diseases. In this paper, with the X-ray phase-contrast imaging technique, we proposed an experiment scheme for the ex vivo mouse brain study, achieving both high spatial resolution and improved soft-tissue contrast. This scheme includes two steps: sample preparation and volume reconstruction. In the first step, we use heparinized saline to displace the blood inside cerebral vessels and then replace it with air making air-filled mouse brain. After sample preparation, X-ray phase-contrast tomography is performed to collect the data for volume reconstruction. Here, we adopt a phase-retrieval combined filtered backprojection method to reconstruct its three-dimensional structure and redesigned the reconstruction kernel. To evaluate its performance, we carried out experiments at Shanghai Synchrotron Radiation Facility. The results show that the air-tissue structured cerebral vasculatures are highly visible with propagation-based phase-contrast imaging and can be clearly resolved in reconstructed cross-images. Besides, functional areas, such as the corpus callosum, corpus striatum, and nuclei, are also clearly resolved. The proposed method is comparable with hematoxylin and eosin staining method but represents the studied mouse brain in three dimensions, offering a potential powerful tool for the research of brain disorders.
Collapse
|
15
|
Liu H, Wu X, Xiao T. Optimization of reconstructed quality of hard x-ray phase microtomography. APPLIED OPTICS 2015; 54:5610-5618. [PMID: 26193002 PMCID: PMC4508876 DOI: 10.1364/ao.54.005610] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
For applications of hard x-ray propagation-based phase-contrast computed microtomography (PPCT) in high-resolution biological research, high spatial resolution and high contrast-to-noise ratio are simultaneously required for tiny structural discrimination and characterization. Most existing micro-CT techniques to improve image quality are limited by high cost, physical limitations, and complexity of the experimental hardware and setup. In this work, a novel PPCT technique, which combines a wavelet-transform-based modulation transform function compensation algorithm and a generalized phase-retrieval algorithm, is proposed to optimize the reconstruction quality of tomographic slices. Our experimental results, which compared the spatial resolutions and contrast-to-noise ratios of reconstructed images, demonstrated the validity of the proposed generalized PPCT technique. The experimental results showed that the proposed generalized PPCT technique is superior to the direct PPCT and the linearized phase-retrieval PPCT techniques. This novel PPCT technique demonstrates great potential for biological imaging, especially for applications that require high spatial resolution and limit radiation exposure.
Collapse
Affiliation(s)
- Huiqiang Liu
- Japan Synchrotron Radiation Research Institute, SPring-8,1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan
| | - Xizeng Wu
- Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama 35233, USA
| | - Tiqiao Xiao
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
| |
Collapse
|
16
|
Chen R, Liu P, Xiao T, Xu LX. X-ray imaging for non-destructive microstructure analysis at SSRF. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2014; 26:7688-7691. [PMID: 25319475 DOI: 10.1002/adma.201402956] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Revised: 08/20/2014] [Indexed: 06/04/2023]
Abstract
The X-ray imaging beamline at the Shanghai Synchrotron Radiation Facility is aimed at developing and evaluating the effectiveness of synchrotron radiation (SR)-based imaging techniques in planar or computed tomography modalities. Several X-ray imaging methods are in use and find extensive applications in many research fields. In this Essay, the status of the methodology development at the beamline is discussed and applications are reviewed.
Collapse
Affiliation(s)
- Rongchang Chen
- Shanghai Institute of Applied Physics, Chinese Academy of Science, Shanghai, 201204, China
| | | | | | | |
Collapse
|
17
|
3D online submicron scale observation of mixed metal powder's microstructure evolution in high temperature and microwave compound fields. ScientificWorldJournal 2014; 2014:684081. [PMID: 24737986 PMCID: PMC3967726 DOI: 10.1155/2014/684081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2013] [Accepted: 01/02/2014] [Indexed: 11/17/2022] Open
Abstract
In order to study the influence on the mechanical properties caused by microstructure evolution of metal powder in extreme environment, 3D real-time observation of the microstructure evolution of Al-Ti mixed powder in high temperature and microwave compound fields was realized by using synchrotron radiation computerized topography (SR-CT) technique; the spatial resolution was enhanced to 0.37 μm/pixel through the designed equipment and the introduction of excellent reconstruction method for the first time. The process of microstructure evolution during sintering was clearly distinguished from 2D and 3D reconstructed images. Typical sintering parameters such as sintering neck size, porosity, and particle size of the sample were presented for quantitative analysis of the influence on the mechanical properties and the sintering kinetics during microwave sintering. The neck size-time curve was obtained and the neck growth exponent was 7.3, which indicated that surface diffusion was the main diffusion mechanism; the reason was the eddy current loss induced by the external microwave fields providing an additional driving force for mass diffusion on the particle surface. From the reconstructed images and the curve of porosity and average particle size versus temperature, it was believed that the presence of liquid phase aluminum accelerated the densification and particle growth.
Collapse
|
18
|
Rositi H, Frindel C, Langer M, Wiart M, Olivier C, Peyrin F, Rousseau D. Information-based analysis of X-ray in-line phase tomography with application to the detection of iron oxide nanoparticles in the brain. OPTICS EXPRESS 2013; 21:27185-27196. [PMID: 24216942 DOI: 10.1364/oe.21.027185] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The study analyzes noise in X-ray in-line phase tomography in a biomedical context. The impact of noise on detection of iron oxide nanoparticles in mouse brain is assessed. The part of the noise due to the imaging system and the part due to biology are quantitatively expressed in a Neyman Pearson detection strategy with two models of noise. This represents a practical extension of previous work on noise in phase-contrast X-ray imaging which focused on the theoretical expression of the signal-to-noise ratio in mono-dimensional phantoms, taking account of the statistical noise of the imaging system only. We also report the impact of the phase retrieval step on detection performance. Taken together, this constitutes a general methodology of practical interest for quantitative extraction of information from X-ray in-line phase tomography, and is also relevant to assessment of contrast agents with a blob-like signature in high resolution imaging.
Collapse
|
19
|
Yan A, Wu X, Liu H. A robust general phase retrieval method for medical applications. JOURNAL OF INSTRUMENTATION : AN IOP AND SISSA JOURNAL 2013; 8:C05007. [PMID: 23894250 PMCID: PMC3721370 DOI: 10.1088/1748-0221/8/05/c05007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
From medical imaging perspective the robustness of a phase retrieval method is of critical importance. In this presentation we compare the robustness of two general phase retrieval methods, namely the transport of intensity equation inversion (TIE-inversion) method and the attenuation partition based (AP-based) method. We showed that the TIE-inversion method, regardless if being assisted with the Tikhonov regularization, failed to retrieve the phase maps in two experimental studies. The failure exposes this method's weakness as being unstable against the noise. In contrast, the sample phase maps are retrieved successfully by using the AP-based method. The stark performance differences of the two methods are rooted in their different techniques dealing with the singularity problem. This comparison shows that the robust AP-based phase retrieval method will be superior to the TIE-inversion method for medical imaging applications where radiation doses are stringently limited.
Collapse
Affiliation(s)
- A. Yan
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35233, U.S.A
| | - X. Wu
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35233, U.S.A
| | - H. Liu
- Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, U.S.A
| |
Collapse
|
20
|
Chen RC, Rigon L, Longo R. Comparison of single distance phase retrieval algorithms by considering different object composition and the effect of statistical and structural noise. OPTICS EXPRESS 2013; 21:7384-7399. [PMID: 23546122 DOI: 10.1364/oe.21.007384] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Phase retrieval is a technique for extracting quantitative phase information from X-ray propagation-based phase-contrast tomography (PPCT). In this paper, the performance of different single distance phase retrieval algorithms will be investigated. The algorithms are herein called phase-attenuation duality Born Algorithm (PAD-BA), phase-attenuation duality Rytov Algorithm (PAD-RA), phase-attenuation duality Modified Bronnikov Algorithm (PAD-MBA), phase-attenuation duality Paganin algorithm (PAD-PA) and phase-attenuation duality Wu Algorithm (PAD-WA), respectively. They are all based on phase-attenuation duality property and on weak absorption of the sample and they employ only a single distance PPCT data. In this paper, they are investigated via simulated noise-free PPCT data considering the fulfillment of PAD property and weakly absorbing conditions, and with experimental PPCT data of a mixture sample containing absorbing and weakly absorbing materials, and of a polymer sample considering different degrees of statistical and structural noise. The simulation shows all algorithms can quantitatively reconstruct the 3D refractive index of a quasi-homogeneous weakly absorbing object from noise-free PPCT data. When the weakly absorbing condition is violated, the PAD-RA and PAD-PA/WA obtain better result than PAD-BA and PAD-MBA that are shown in both simulation and mixture sample results. When considering the statistical noise, the contrast-to-noise ratio values decreases as the photon number is reduced. The structural noise study shows that the result is progressively corrupted by ring-like artifacts with the increase of structural noise (i.e. phantom thickness). The PAD-RA and PAD-PA/WA gain better density resolution than the PAD-BA and PAD-MBA in both statistical and structural noise study.
Collapse
Affiliation(s)
- R C Chen
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, China.
| | | | | |
Collapse
|
21
|
Wang Y, Yang Y, Xiao T, Liu K, Clennell B, Zhang G, Wang H. Synchrotron-Based Data-Constrained Modeling Analysis of Microscopic Mineral Distributions in Limestone. ACTA ACUST UNITED AC 2013. [DOI: 10.4236/ijg.2013.42032] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
22
|
Bravin A, Coan P, Suortti P. X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Phys Med Biol 2012; 58:R1-35. [PMID: 23220766 DOI: 10.1088/0031-9155/58/1/r1] [Citation(s) in RCA: 379] [Impact Index Per Article: 31.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Phase-contrast x-ray imaging (PCI) is an innovative method that is sensitive to the refraction of the x-rays in matter. PCI is particularly adapted to visualize weakly absorbing details like those often encountered in biology and medicine. In past years, PCI has become one of the most used imaging methods in laboratory and preclinical studies: its unique characteristics allow high contrast 3D visualization of thick and complex samples even at high spatial resolution. Applications have covered a wide range of pathologies and organs, and are more and more often performed in vivo. Several techniques are now available to exploit and visualize the phase-contrast: propagation- and analyzer-based, crystal and grating interferometry and non-interferometric methods like the coded aperture. In this review, covering the last five years, we will give an overview of the main theoretical and experimental developments and of the important steps performed towards the clinical implementation of PCI.
Collapse
Affiliation(s)
- Alberto Bravin
- European Synchrotron Radiation Facility, 6 rue Horowitz, 38043 Grenoble Cedex, France.
| | | | | |
Collapse
|
23
|
Boone MN, Devulder W, Dierick M, Brabant L, Pauwels E, Van Hoorebeke L. Comparison of two single-image phase-retrieval algorithms for in-line x-ray phase-contrast imaging. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2012; 29:2667-2672. [PMID: 23455917 DOI: 10.1364/josaa.29.002667] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The attenuation of x-rays in a material forms the basis of x-ray radiography and tomography. By measuring the transmission of the x-rays over a large amount of raypaths, the three-dimensional (3D) distribution of the x-ray linear attenuation coefficient can be reconstructed in a 3D volume. In x-ray microtomography (μCT), however, the x-ray refraction yields a significant signal in the transmission image and the 3D distribution of the refractive index can be reconstructed in a 3D volume. To do so, several methods exist, on both a hardware and software level. In this paper, we compare two similar software methods, the modified Bronnikov algorithm and the simultaneous phase-and-amplitude retrieval. The first method assumes a pure phase object, whereas the latter assumes a homogeneous object. Although these assumptions seem very restrictive, both methods have proven to yield good results on experimental data.
Collapse
Affiliation(s)
- Matthieu N Boone
- Ghent University, Department of Physics and Astronomy Proeftuinstraat 86, Gent B-9000, Belgium.
| | | | | | | | | | | |
Collapse
|
24
|
Chen RC, Dreossi D, Mancini L, Menk R, Rigon L, Xiao TQ, Longo R. PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction. JOURNAL OF SYNCHROTRON RADIATION 2012; 19:836-45. [PMID: 22898966 DOI: 10.1107/s0909049512029731] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Accepted: 06/29/2012] [Indexed: 05/22/2023]
Abstract
Synchrotron-radiation computed tomography has been applied in many research fields. Here, PITRE (Phase-sensitive X-ray Image processing and Tomography REconstruction) and PITRE_BM (PITRE Batch Manager) are presented. PITRE supports phase retrieval for propagation-based phase-contrast imaging/tomography (PPCI/PPCT), extracts apparent absorption, refractive and scattering information of diffraction enhanced imaging (DEI), and allows parallel-beam tomography reconstruction for conventional absorption CT data and for PPCT phase retrieved and DEI-CT extracted information. PITRE_BM is a batch processing manager for PITRE: it executes a series of tasks, created via PITRE, without manual intervention. Both PITRE and PITRE_BM are coded in Interactive Data Language (IDL), and have a user-friendly graphical user interface. They are freeware and can run on Microsoft Windows systems via IDL Virtual Machine, which can be downloaded for free and does not require a license. The data-processing principle and some examples of application will be presented.
Collapse
|
25
|
Mayo SC, Stevenson AW, Wilkins SW. In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science. MATERIALS 2012; 5:937-965. [PMID: 28817018 PMCID: PMC5458972 DOI: 10.3390/ma5050937] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2012] [Revised: 05/11/2012] [Accepted: 05/16/2012] [Indexed: 11/21/2022]
Abstract
X-ray phase-contrast imaging and tomography make use of the refraction of X-rays by the sample in image formation. This provides considerable additional information in the image compared to conventional X-ray imaging methods, which rely solely on X-ray absorption by the sample. Phase-contrast imaging highlights edges and internal boundaries of a sample and is thus complementary to absorption contrast, which is more sensitive to the bulk of the sample. Phase-contrast can also be used to image low-density materials, which do not absorb X-rays sufficiently to form a conventional X-ray image. In the context of materials science, X-ray phase-contrast imaging and tomography have particular value in the 2D and 3D characterization of low-density materials, the detection of cracks and voids and the analysis of composites and multiphase materials where the different components have similar X-ray attenuation coefficients. Here we review the use of phase-contrast imaging and tomography for a wide variety of materials science characterization problems using both synchrotron and laboratory sources and further demonstrate the particular benefits of phase contrast in the laboratory setting with a series of case studies.
Collapse
Affiliation(s)
- Sheridan C Mayo
- CSIRO Materials Science and Engineering, Private Bag 33, Clayton, VIC 3169, Australia.
| | - Andrew W Stevenson
- CSIRO Materials Science and Engineering, Private Bag 33, Clayton, VIC 3169, Australia.
| | - Stephen W Wilkins
- CSIRO Materials Science and Engineering, Private Bag 33, Clayton, VIC 3169, Australia.
| |
Collapse
|