Searles K, Shalabi N, Hohert G, Gharib N, Jayhooni SMH, Lane PM, Takahata K. Distal planar rotary scanner for endoscopic optical coherence tomography. Biomed Eng Lett 2024; 14:583-592. [PMID: 38645593 PMCID: PMC11026329 DOI: 10.1007/s13534-024-00353-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 01/10/2024] [Accepted: 01/18/2024] [Indexed: 04/23/2024] Open
Abstract
Optical coherence tomography (OCT) is becoming a more common endoscopic imaging modality for detecting and treating disease given its high resolution and image quality. To use OCT for 3-dimensional imaging of small lumen, embedding an optical scanner at the distal end of an endoscopic probe for circumferential scanning the probing light is a promising way to implement high-quality imaging unachievable with the conventional method of revolving an entire probe. To this end, the present work proposes a hollow and planar micro rotary actuator for its use as an endoscopic distal scanner. A miniaturized design of this ferrofluid-assisted electromagnetic actuator is prototyped to act as a full 360° optical scanner, which is integrated at the tip of a fiber-optic probe together with a gradient-index lens for use with OCT. The scanner is revealed to achieve a notably improved dynamic performance that shows a maximum speed of 6500 rpm, representing 325% of the same reported with the preceding design, while staying below the thermal limit for safe in-vivo use. The scanner is demonstrated to perform real-time OCT using human fingers as live tissue samples for the imaging tests. The acquired images display no shadows from the electrical wires to the scanner, given its hollow architecture that allows the probing light to pass through the actuator body, as well as the quality high enough to differentiate the dermis from the epidermis while resolving individual sweat glands, proving the effectiveness of the prototyped scanner design for endoscopic OCT application.
Collapse
Affiliation(s)
- Kyle Searles
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3 Canada
| | - Nabil Shalabi
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4 Canada
| | - Geoffrey Hohert
- Integrative Oncology, BC Cancer Research Institute, Vancouver, BC V5Z 4E6 Canada
| | - Nirvana Gharib
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4 Canada
| | | | - Pierre M. Lane
- Integrative Oncology, BC Cancer Research Institute, Vancouver, BC V5Z 4E6 Canada
| | - Kenichi Takahata
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3 Canada
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4 Canada
| |
Collapse
|
2
|
Shi Y, Liu J, Gong Z, Burger C, Jayaraman V, Wang RK. Multi-channel delay sampling to extend imaging depth in high-speed swept-source OCT systems. OPTICS LETTERS 2024; 49:2217-2220. [PMID: 38691683 DOI: 10.1364/ol.517493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Accepted: 03/19/2024] [Indexed: 05/03/2024]
Abstract
We present a multi-channel delay sampling method to extend imaging depth in high-speed swept-source optical coherence tomography (SS-OCT). A balanced detector captures interference signals, converting them into electrical signals, which are then split into N channels, each with fixed time delays determined by the length of electrical cables. Then, they are digitized by an N-channel acquisition card. A calibration procedure is utilized to compensate for non-uniform phase shifts resulting from fixed time delays. The N-channel signals are merged in k-space and resampled to obtain a linearized spectrum, which increases the sampling rate by a factor of N, thereby extending the ranging distance by N times, all without altering k-clock triggering or sacrificing other imaging performance. The signal-to-noise ratio and sensitivity within the original depth range also have been enhanced. This advancement contributes to the improvement of the overall performance of SS-OCT systems.
Collapse
|
3
|
Mino T, Moriguchi Y, Tamura M, Matsumoto A, Kubota A, Akiba M, Hwang Y, Makita S, Yasuno Y, Enaida H, Fujimoto JG, Wang Z. Extended and adjustable field-of-view of variable interscan time analysis by ammonite-scanning swept-source optical coherence tomography angiography. BIOMEDICAL OPTICS EXPRESS 2023; 14:4112-4125. [PMID: 37799706 PMCID: PMC10549733 DOI: 10.1364/boe.491611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 07/01/2023] [Accepted: 07/01/2023] [Indexed: 10/07/2023]
Abstract
A novel scanning protocol, ammonite scan, is proposed for widefield optical coherence tomography angiography (OCTA) and relative retinal blood flow velocity imaging in the human retina using variable interscan time analysis (VISTA). A repeated circle scan using a 400 kHz swept-source was employed to achieve an interscan time of 1.28 ms. The center of the repeated circular scan continuously moved spirally towards the peripheral region, ensuring an extended and adjustable scan range while preserving the short interscan time. Image artifacts due to eye movement were eliminated via extra motion-correction processing using data redundancy. The relative blood flow velocity in superficial and deep plexus layers was calculated from the VISTA image, and their ratio was used to explore the microvascular flow parameter in the healthy human eye.
Collapse
Affiliation(s)
- Toshihiro Mino
- Topcon Advanced Biomedical Imaging Laboratory, Topcon Medical Systems, 111 Bauer Drive, Oakland, NJ 07436, USA
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Yoshikiyo Moriguchi
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Masato Tamura
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Akiko Matsumoto
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Atsushi Kubota
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Masahiro Akiba
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Yunchan Hwang
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Shuichi Makita
- Computational Optics Group, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Hiroshi Enaida
- Department of Ophthalmology, Faculty of Medicine, Saga University, 5-1-1 Nabeshima, Saga 849-8501, Japan
| | - James G. Fujimoto
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Zhenguo Wang
- Topcon Advanced Biomedical Imaging Laboratory, Topcon Medical Systems, 111 Bauer Drive, Oakland, NJ 07436, USA
| |
Collapse
|
4
|
Kim HJ, Sritandi W, Xiong Z, Ho JS. Bioelectronic devices for light-based diagnostics and therapies. BIOPHYSICS REVIEWS 2023; 4:011304. [PMID: 38505817 PMCID: PMC10903427 DOI: 10.1063/5.0102811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 12/28/2022] [Indexed: 03/21/2024]
Abstract
Light has broad applications in medicine as a tool for diagnosis and therapy. Recent advances in optical technology and bioelectronics have opened opportunities for wearable, ingestible, and implantable devices that use light to continuously monitor health and precisely treat diseases. In this review, we discuss recent progress in the development and application of light-based bioelectronic devices. We summarize the key features of the technologies underlying these devices, including light sources, light detectors, energy storage and harvesting, and wireless power and communications. We investigate the current state of bioelectronic devices for the continuous measurement of health and on-demand delivery of therapy. Finally, we highlight major challenges and opportunities associated with light-based bioelectronic devices and discuss their promise for enabling digital forms of health care.
Collapse
Affiliation(s)
| | - Weni Sritandi
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore
| | | | - John S. Ho
- Author to whom correspondence should be addressed:
| |
Collapse
|
5
|
Otuya DO, Dechene NM, Poshtupaka D, Judson S, Carlson CJ, Zemlok SK, Sevieri E, Choy P, Shore RE, De León-Peralta E, Cirio AA, Rihm TW, Krall AA, Gavgiotaki E, Dong J, Silva SL, Baillargeon A, Baldwin G, Gao AH, Jansa Z, Barrios A, Ryan E, Bhat NGM, Balmasheva I, Chung A, Grant CN, Bablouzian AL, Beatty M, Ahsen OO, Zheng H, Tearney GJ. Passively scanned, single-fiber optical coherence tomography probes for gastrointestinal devices. Lasers Surg Med 2022; 54:935-944. [PMID: 35708124 PMCID: PMC9541095 DOI: 10.1002/lsm.23576] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 05/31/2022] [Accepted: 06/03/2022] [Indexed: 10/25/2022]
Abstract
BACKGROUND/OBJECTIVES Optical coherence tomography (OCT) uses low coherence interferometry to obtain depth-resolved tissue reflectivity profiles (M-mode) and transverse beam scanning to create images of two-dimensional tissue morphology (B-mode). Endoscopic OCT imaging probes typically employ proximal or distal mechanical beam scanning mechanisms that increase cost, complexity, and size. Here, we demonstrate in the gastrointestinal (GI) tracts of unsedated human patients, that a passive, single-fiber probe can be used to guide device placement, conduct device-tissue physical contact sensing, and obtain two-dimensional OCT images via M-to-B-mode conversion. MATERIALS AND METHODS We designed and developed ultrasmall, manually scannable, side- and forward-viewing single fiber-optic probes that can capture M-mode OCT data. Side-viewing M-mode OCT probes were incorporated into brush biopsy devices designed to harvest the microbiome and forward-viewing M-mode OCT probes were integrated into devices that measure intestinal potential difference (IPD). The M-mode OCT probe-coupled devices were utilized in the GI tract in six unsedated patients in vivo. M-mode data were converted into B-mode images using an M-to-B-mode conversion algorithm. The effectiveness of physical contact sensing by the M-mode OCT probes was assessed by comparing the variances of the IPD values when the probe was in physical contact with the tissue versus when it was not. The capacity of forward- and side-viewing M-mode OCT probes to produce high-quality B-mode images was compared by computing the percentages of the M-to-B-mode images that showed close contact between the probe and the luminal surface. Passively scanned M-to-B-mode images were qualitatively compared to B-mode images obtained by mechanical scanning OCT tethered capsule endomicroscopy (TCE) imaging devices. RESULTS The incorporation of M-mode OCT probes in these nonendoscopic GI devices safely and effectively enabled M-mode OCT imaging, facilitating real-time device placement guidance and contact sensing in vivo. Results showed that M-mode OCT contact sensing improved the variance of IPD measurements threefold and side-viewing probes increased M-to-B-mode image visibility by 10%. Images of the esophagus, stomach, and duodenum generated by the passively scanned probes and M-to-B-mode conversion were qualitatively superior to B-mode images obtained by mechanically scanning OCT TCE devices. CONCLUSION These results show that passive, single optical fiber OCT probes can be effectively utilized for nonendoscopic device placement guidance, device contact sensing, and two-dimensional morphologic imaging in the human GI tract in vivo. Due to their small size, lower cost, and reduced complexity, these M-mode OCT probes may provide an easier avenue for the incorporation of OCT functionality into endoscopic/nonendoscopic devices.
Collapse
Affiliation(s)
- David O Otuya
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA.,Harvard Medical School, Boston, Massachusetts, USA
| | - Nicholas M Dechene
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Darina Poshtupaka
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Seth Judson
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Camella J Carlson
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Sarah K Zemlok
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Evan Sevieri
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Peter Choy
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Rachel E Shore
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | | - Alissa A Cirio
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Tyler W Rihm
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Alexander A Krall
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Evangelia Gavgiotaki
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA.,Harvard Medical School, Boston, Massachusetts, USA
| | - Jing Dong
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Sarah L Silva
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Aaron Baillargeon
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Grace Baldwin
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Anna H Gao
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Zachary Jansa
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Amilcar Barrios
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Emily Ryan
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Nitasha G M Bhat
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Indira Balmasheva
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Anita Chung
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Catriona N Grant
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Ara L Bablouzian
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Matthew Beatty
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Osman O Ahsen
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Hui Zheng
- Harvard Medical School, Boston, Massachusetts, USA.,Massachusetts General Hospital Biostatistics, Boston, Massachusetts, USA
| | - Guillermo J Tearney
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA.,Harvard Medical School, Boston, Massachusetts, USA.,Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Harvard-MIT Division of Health Sciences and Technology (HST), Boston, Massachusetts, USA
| |
Collapse
|
6
|
Endoscopic OCT Angiography Using Clinical Proximal-End Scanning Catheters. PHOTONICS 2022. [DOI: 10.3390/photonics9050329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Endoscopic optical coherence tomography angiography (OCTA) is a promising modality to inspect the microvasculature of inner organs in the early-stage tumor diagnosis. However, an endoscopic clinical proximal-end scanning catheter has limited flow imaging capability due to the nonuniform rotational distortion (NURD) and physiological motion. In this study, a combined local and global (CLG) optical flow algorithm was used to estimate the motion vectors caused by NURD and physiological motion. The motion vectors were used to bicubic-interpolation-resample the OCT structure to ensure that the circumferential pixels were equally spaced in the space domain. Then, angiograms were computed based on the statistical relation between inverse SNR (iSNR) and amplitude decorrelation (IDa), termed as IDa-OCTA. Finally, the ability of this technique for endoscopic OCTA imaging was demonstrated by flow phantom experiments and human nailfold capillary imaging.
Collapse
|
7
|
Yuan W, Feng Y, Chen D, Gharibani P, Chen JDZ, Yu H, Li X. In vivo assessment of inflammatory bowel disease in rats with ultrahigh-resolution colonoscopic OCT. BIOMEDICAL OPTICS EXPRESS 2022; 13:2091-2102. [PMID: 35519259 PMCID: PMC9045891 DOI: 10.1364/boe.453396] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 02/26/2022] [Accepted: 03/01/2022] [Indexed: 06/12/2023]
Abstract
A technology capable of high-resolution, label-free imaging of subtle pathology in vivo during colonoscopy is imperative for the early detection of disease and the performance of accurate biopsies. While colonoscopic OCT has been developed to visualize colonic microstructures beyond the mucosal surface, its clinical potential remains limited by sub-optimal resolution (∼6.5 µm in tissue), inadequate imaging contrast, and a lack of high-resolution OCT criteria for lesion detection. In this study, we developed an ultrahigh-resolution (UHR) colonoscopic OCT and evaluated its ability to volumetrically visualize and identify the pathological features of inflammatory bowel disease (IBD) in a rat model. Owing to its improved resolution (∼1.7 µm in tissue) and enhanced contrast, UHR colonoscopic OCT can accurately delineate fine colonic microstructures and identify the pathophysiological characteristics of IBD in vivo. By using a quantitative optical attenuation map, UHR colonoscopic OCT is able to differentiate diseased tissue (such as crypt distortion and microabscess) from normal colonic mucosa over a large field of view in vivo. Our results suggest the clinical potential of UHR colonoscopic OCT for in vivo assessment of IBD pathology.
Collapse
Affiliation(s)
- Wu Yuan
- Department of Biomedical Engineering, School of Medicine, Johns Hopkins University, Baltimore, MD 21205, USA
- Department of Biomedical Engineering and Shun Hing Institute of Advanced Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| | - Yan Feng
- Department of Pathology and Laboratory Medicine, Pennsylvania Hospital, Penn Medicine, Philadelphia, PA 19107, USA
| | - Defu Chen
- Department of Biomedical Engineering, School of Medicine, Johns Hopkins University, Baltimore, MD 21205, USA
| | - Payam Gharibani
- Division of Gastroenterology and Hepatology, School of Medicine, Johns Hopkins University, Baltimore, MD 21205, USA
| | - Jiande D. Z. Chen
- Division of Gastroenterology and Hepatology, School of Medicine, Johns Hopkins University, Baltimore, MD 21205, USA
| | - Huimin Yu
- Division of Gastroenterology and Hepatology, School of Medicine, Johns Hopkins University, Baltimore, MD 21205, USA
| | - Xingde Li
- Department of Biomedical Engineering, School of Medicine, Johns Hopkins University, Baltimore, MD 21205, USA
| |
Collapse
|
8
|
Leitgeb R, Placzek F, Rank E, Krainz L, Haindl R, Li Q, Liu M, Andreana M, Unterhuber A, Schmoll T, Drexler W. Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210150-PER. [PMID: 34672145 PMCID: PMC8528212 DOI: 10.1117/1.jbo.26.10.100601] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 09/23/2021] [Indexed: 05/17/2023]
Abstract
SIGNIFICANCE After three decades, more than 75,000 publications, tens of companies being involved in its commercialization, and a global market perspective of about USD 1.5 billion in 2023, optical coherence tomography (OCT) has become one of the fastest successfully translated imaging techniques with substantial clinical and economic impacts and acceptance. AIM Our perspective focuses on disruptive forward-looking innovations and key technologies to further boost OCT performance and therefore enable significantly enhanced medical diagnosis. APPROACH A comprehensive review of state-of-the-art accomplishments in OCT has been performed. RESULTS The most disruptive future OCT innovations include imaging resolution and speed (single-beam raster scanning versus parallelization) improvement, new implementations for dual modality or even multimodality systems, and using endogenous or exogenous contrast in these hybrid OCT systems targeting molecular and metabolic imaging. Aside from OCT angiography, no other functional or contrast enhancing OCT extension has accomplished comparable clinical and commercial impacts. Some more recently developed extensions, e.g., optical coherence elastography, dynamic contrast OCT, optoretinography, and artificial intelligence enhanced OCT are also considered with high potential for the future. In addition, OCT miniaturization for portable, compact, handheld, and/or cost-effective capsule-based OCT applications, home-OCT, and self-OCT systems based on micro-optic assemblies or photonic integrated circuits will revolutionize new applications and availability in the near future. Finally, clinical translation of OCT including medical device regulatory challenges will continue to be absolutely essential. CONCLUSIONS With its exquisite non-invasive, micrometer resolution depth sectioning capability, OCT has especially revolutionized ophthalmic diagnosis and hence is the fastest adopted imaging technology in the history of ophthalmology. Nonetheless, OCT has not been completely exploited and has substantial growth potential-in academics as well as in industry. This applies not only to the ophthalmic application field, but also especially to the original motivation of OCT to enable optical biopsy, i.e., the in situ imaging of tissue microstructure with a resolution approaching that of histology but without the need for tissue excision.
Collapse
Affiliation(s)
- Rainer Leitgeb
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Medical University of Vienna, Christian Doppler Laboratory OPTRAMED, Vienna, Austria
| | - Fabian Placzek
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Elisabet Rank
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Lisa Krainz
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Richard Haindl
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Qian Li
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Mengyang Liu
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Marco Andreana
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Angelika Unterhuber
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Tilman Schmoll
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Carl Zeiss Meditec, Inc., Dublin, California, United States
| | - Wolfgang Drexler
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Address all correspondence to Wolfgang Drexler,
| |
Collapse
|
9
|
Wartak A, Kelada AK, Leon Alarcon PA, Bablouzian AL, Ahsen OO, Gregg AL, Wei Y, Bollavaram K, Sheil CJ, Farewell E, VanTol S, Smith R, Grahmann P, Baillargeon AR, Gardecki JA, Tearney GJ. Dual-modality optical coherence tomography and fluorescence tethered capsule endomicroscopy. BIOMEDICAL OPTICS EXPRESS 2021; 12:4308-4323. [PMID: 34457416 PMCID: PMC8367220 DOI: 10.1364/boe.422453] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 06/02/2021] [Accepted: 06/02/2021] [Indexed: 06/13/2023]
Abstract
OCT tethered capsule endomicroscopy (TCE) is an emerging noninvasive diagnostic imaging technology for gastrointestinal (GI) tract disorders. OCT measures tissue reflectivity that provides morphologic image contrast, and thus is incapable of ascertaining molecular information that can be useful for improving diagnostic accuracy. Here, we introduce an extension to OCT TCE that includes a fluorescence (FL) imaging channel for attaining complementary, co-registered molecular contrast. We present the development of an OCT-FL TCE capsule and a portable, plug-and-play OCT-FL imaging system. The technology is validated in phantom experiments and feasibility is demonstrated in a methylene blue (MB)-stained swine esophageal injury model, ex vivo and in vivo.
Collapse
Affiliation(s)
- Andreas Wartak
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Department of Dermatology, Harvard Medical School, Harvard University, Boston, MA 02115, USA
| | - Alfred K. Kelada
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Paola A. Leon Alarcon
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Ara L. Bablouzian
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Osman O. Ahsen
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Department of Dermatology, Harvard Medical School, Harvard University, Boston, MA 02115, USA
| | - Abigail L. Gregg
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Yuxiao Wei
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, USA
| | - Keval Bollavaram
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
| | - Conor J. Sheil
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Department of Dermatology, Harvard Medical School, Harvard University, Boston, MA 02115, USA
| | - Edward Farewell
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Schuyler VanTol
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Rachel Smith
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Patricia Grahmann
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Aaron R. Baillargeon
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Joseph A. Gardecki
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Department of Dermatology, Harvard Medical School, Harvard University, Boston, MA 02115, USA
| | - Guillermo J. Tearney
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, USA
- Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
10
|
Zhang J, Nguyen T, Potsaid B, Jayaraman V, Burgner C, Chen S, Li J, Liang K, Cable A, Traverso G, Mashimo H, Fujimoto JG. Multi-MHz MEMS-VCSEL swept-source optical coherence tomography for endoscopic structural and angiographic imaging with miniaturized brushless motor probes. BIOMEDICAL OPTICS EXPRESS 2021; 12:2384-2403. [PMID: 33996236 PMCID: PMC8086463 DOI: 10.1364/boe.420394] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 03/10/2021] [Accepted: 03/18/2021] [Indexed: 05/02/2023]
Abstract
Swept source optical coherence tomography (SS-OCT) enables volumetric imaging of subsurface structure. However, applications requiring wide fields of view (FOV), rapid imaging, and higher resolutions have been challenging because multi-MHz axial scan (A-scan) rates are needed. We describe a microelectromechanical systems vertical cavity surface-emitting laser (MEMS-VCSEL) SS-OCT technology for A-scan rates of 2.4 and 3.0 MHz. Sweep to sweep calibration and resampling are performed using dual channel acquisition of the OCT signal and a Mach Zehnder interferometer signal, overcoming inherent optical clock limitations and enabling higher performance. We demonstrate ultrahigh speed structural SS-OCT and OCT angiography (OCTA) imaging of the swine gastrointestinal tract using a suite of miniaturized brushless motor probes, including a 3.2 mm diameter micromotor OCT catheter, a 12 mm diameter tethered OCT capsule, and a 12 mm diameter widefield OCTA probe. MEMS-VCSELs promise to enable ultrahigh speed SS-OCT with a scalable, low cost, and manufacturable technology, suitable for a diverse range of imaging applications.
Collapse
Affiliation(s)
- Jason Zhang
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- These authors contributed equally to this work
| | - Tan Nguyen
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- These authors contributed equally to this work
| | - Benjamin Potsaid
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Advanced Imaging Group, Thorlabs Inc., Newton, NJ 07860, USA
| | | | | | - Siyu Chen
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jinxi Li
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Kaicheng Liang
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Alex Cable
- Advanced Imaging Group, Thorlabs Inc., Newton, NJ 07860, USA
| | - Giovanni Traverso
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Gastroenterology, Massachusetts General Hospital, Boston, MA 02114, USA
- Division of Gastroenterology, Brigham and Women’s Hospital, Boston, MA 02115, USA
- Harvard Medical School, Boston, MA 02115, USA
| | - Hiroshi Mashimo
- Harvard Medical School, Boston, MA 02115, USA
- Veterans Affairs Boston Healthcare System, Boston, MA 02132, USA
| | - James G. Fujimoto
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
11
|
Mashimo H, Gordon SR, Singh SK. Advanced endoscopic imaging for detecting and guiding therapy of early neoplasias of the esophagus. Ann N Y Acad Sci 2020; 1482:61-76. [PMID: 33184872 DOI: 10.1111/nyas.14523] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 10/08/2020] [Accepted: 10/13/2020] [Indexed: 12/16/2022]
Abstract
Esophageal cancers, largely adenocarcinoma in Western countries and squamous cell cancer in Asia, present a significant burden of disease and remain one of the most lethal of cancers. Key to improving survival is the development and adoption of new imaging modalities to identify early neoplastic lesions, which may be small, multifocal, subsurface, and difficult to detect by standard endoscopy. Such advanced imaging is particularly relevant with the emergence of ablative techniques that often require multiple endoscopic sessions and may be complicated by bleeding, pain, strictures, and recurrences. Assessing the specific location, depth of involvement, and features correlated with neoplastic progression or incomplete treatment may optimize treatments. While not comprehensive of all endoscopic imaging modalities, we review here some of the recent advances in endoscopic luminal imaging, particularly with surface contrast enhancement using virtual chromoendoscopy, highly magnified subsurface imaging with confocal endomicroscopy, optical coherence tomography, elastic scattering spectroscopy, angle-resolved low-coherence interferometry, and light scattering spectroscopy. While there is no single ideal imaging modality, various multimodal instruments are also being investigated. The future of combining computer-aided assessments, molecular markers, and improved imaging technologies to help localize and ablate early neoplastic lesions shed hope for improved disease outcome.
Collapse
Affiliation(s)
- Hiroshi Mashimo
- VA Boston Healthcare System, Boston, Massachusetts.,Harvard Medical School, Boston, Massachusetts
| | - Stuart R Gordon
- Dartmouth-Hitchcock Medical Center, Dartmouth University, Lebanon, New Hampshire
| | - Satish K Singh
- VA Boston Healthcare System, Boston, Massachusetts.,Boston University School of Medicine, Boston, Massachusetts
| |
Collapse
|
12
|
Jiao S. Biomedical optical imaging technology and applications: From basic research toward clinical diagnosis. Exp Biol Med (Maywood) 2020; 245:269-272. [PMID: 32141780 DOI: 10.1177/1535370220909543] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Affiliation(s)
- Shuliang Jiao
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
| |
Collapse
|
13
|
López-Marín A, Springeling G, Beurskens R, van Beusekom H, van der Steen AFW, Koch AD, Bouma BE, Huber R, van Soest G, Wang T. Motorized capsule for shadow-free OCT imaging and synchronous beam control. OPTICS LETTERS 2019; 44:3641-3644. [PMID: 31368932 DOI: 10.1364/ol.44.003641] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
We demonstrate a tethered motorized capsule for unobstructed optical coherence tomography (OCT) imaging of the esophagus. By using a distal reflector design, we avoided the common shadow artifact induced by the motor wires. A synchronous driving technique features three types of beam-scanning modes of the capsule, i.e., circumferential beam scanning, localized beam scanning, and accurate beam positioning. We characterized these three modes and carried out ex vivo imaging experiments using the capsule. The results show that the capsule can potentially be a useful tool for diagnostic OCT imaging and OCT-guided biopsy and therapy of the esophagus.
Collapse
|
14
|
Kim DY, Hwang K, Ahn J, Seo YH, Kim JB, Lee S, Yoon JH, Kong E, Jeong Y, Jon S, Kim P, Jeong KH. Lissajous Scanning Two-photon Endomicroscope for In vivo Tissue Imaging. Sci Rep 2019; 9:3560. [PMID: 30837501 PMCID: PMC6401070 DOI: 10.1038/s41598-019-38762-w] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 12/31/2018] [Indexed: 12/13/2022] Open
Abstract
An endomicroscope opens new frontiers of non-invasive biopsy for in vivo imaging applications. Here we report two-photon laser scanning endomicroscope for in vivo cellular and tissue imaging using a Lissajous fiber scanner. The fiber scanner consists of a piezoelectric (PZT) tube, a single double-clad fiber (DCF) with high fluorescence collection, and a micro-tethered-silicon-oscillator (MTSO) for the separation of biaxial resonant scanning frequencies. The endomicroscopic imaging exhibits 5 frames/s with 99% in scanning density by using the selection rule of scanning frequencies. The endomicroscopic scanner was compactly packaged within a stainless tube of 2.6 mm in diameter with a high NA gradient-index (GRIN) lens, which can be easily inserted into the working channel of a conventional laparoscope. The lateral and axial resolutions of the endomicroscope are 0.70 µm and 7.6 μm, respectively. Two-photon fluorescence images of a stained kidney section and miscellaneous ex vivo and in vivo organs from wild type and green fluorescent protein transgenic (GFP-TG) mice were successfully obtained by using the endomicroscope. The endomicroscope also obtained label free images including autofluorescence and second-harmonic generation of an ear tissue of Thy1-GCaMP6 (GP5.17) mouse. The Lissajous scanning two-photon endomicroscope can provide a compact handheld platform for in vivo tissue imaging or optical biopsy applications.
Collapse
Affiliation(s)
- Daniel Youngsuk Kim
- Department of Bio and Brain Engineering, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Kyungmin Hwang
- Department of Bio and Brain Engineering, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Jinhyo Ahn
- Biomedical Science and Engineering Interdisciplinary Program, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Yeong-Hyeon Seo
- Department of Bio and Brain Engineering, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Jae-Beom Kim
- Department of Bio and Brain Engineering, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Soyoung Lee
- Department of Biological Sciences, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute for the BioCentury, Daejeon, 34141, Republic of Korea
| | - Jin-Hui Yoon
- Department of Bio and Brain Engineering, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Eunji Kong
- Biomedical Science and Engineering Interdisciplinary Program, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Yong Jeong
- Department of Bio and Brain Engineering, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Sangyong Jon
- Department of Biological Sciences, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute for the BioCentury, Daejeon, 34141, Republic of Korea
| | - Pilhan Kim
- Biomedical Science and Engineering Interdisciplinary Program, KAIST, Daejeon, 34141, Republic of Korea.,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea
| | - Ki-Hun Jeong
- Department of Bio and Brain Engineering, KAIST, Daejeon, 34141, Republic of Korea. .,KAIST Institute of Health science and technology, Daejeon, 34141, Republic of Korea.
| |
Collapse
|
15
|
Liang CP, Dong J, Ford T, Reddy R, Hosseiny H, Farrokhi H, Beatty M, Singh K, Osman H, Vuong B, Baldwin G, Grant C, Giddings S, Gora MJ, Rosenberg M, Nishioka N, Tearney G. Optical coherence tomography-guided laser marking with tethered capsule endomicroscopy in unsedated patients. BIOMEDICAL OPTICS EXPRESS 2019; 10:1207-1222. [PMID: 30891340 PMCID: PMC6420285 DOI: 10.1364/boe.10.001207] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 12/23/2018] [Accepted: 01/06/2019] [Indexed: 05/28/2023]
Abstract
Tethered capsule endomicroscopy (TCE) is an emerging screening technology that comprehensively obtains microstructural OCT images of the gastrointestinal (GI) tract in unsedated patients. To advance clinical adoption of this imaging technique, it will be important to validate TCE images with co-localized histology, the current diagnostic gold standard. One method for co-localizing OCT images with histology is image-targeted laser marking, which has previously been implemented using a driveshaft-based, balloon OCT catheter, deployed during endoscopy. In this paper, we present a TCE device that scans and targets the imaging beam using a low-cost stepper motor that is integrated inside the capsule. In combination with a 4-laser-diode, high power 1430/1450 nm marking laser system (800 mW on the sample and 1s pulse duration), this technology generated clearly visible marks, with a spatial targeting accuracy of better than 0.5 mm. A laser safety study was done on swine esophagus ex vivo, showing that these exposure parameters did not alter the submucosa, with a large, 4-5x safety margin. The technology was demonstrated in living human subjects and shown to be effective for co-localizing OCT TCE images to biopsies obtained during subsequent endoscopy.
Collapse
Affiliation(s)
- Chia-Pin Liang
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Jing Dong
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Tim Ford
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Rohith Reddy
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Hamid Hosseiny
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Hamid Farrokhi
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Matthew Beatty
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Kanwarpal Singh
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Hany Osman
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Barry Vuong
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Grace Baldwin
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Catriona Grant
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Sarah Giddings
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Michalina J. Gora
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
- ICube Laboratory, CNRS, Strasbourg University, Strasbourg, France
| | - Mireille Rosenberg
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Norman Nishioka
- Department of Gastroenterology, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Guillermo Tearney
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
- Department of Pathology, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| |
Collapse
|
16
|
Lee AMD, MacAulay C, Lane P. Depth-multiplexed optical coherence tomography dual-beam manually-actuated distortion-corrected imaging (DMDI) with a micromotor catheter. BIOMEDICAL OPTICS EXPRESS 2018; 9:5678-5690. [PMID: 30460155 PMCID: PMC6238937 DOI: 10.1364/boe.9.005678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Revised: 10/03/2018] [Accepted: 10/03/2018] [Indexed: 06/09/2023]
Abstract
We present a new micromotor catheter implementation of dual-beam manually-actuated distortion-corrected imaging (DMDI). The new catheter called a depth-multiplexed dual-beam micromotor catheter, or mDBMC, maintains the primary advantage of unlimited field-of-view distortion-corrected imaging along the catheter axis. The mDBMC uses a polarization beam splitter and cube mirror to create two beams that scan circularly with approximately constant separation at the catheter surface. This arrangement also multiplexes both imaging channels into a single optical coherence tomography channel by offsetting them in depth, requiring half the data bandwidth compared to previous DMDI demonstrations that used two parallel image acquisition systems. Furthermore, the relatively simple scanning pattern of the two beams enables a straightforward automated distortion correction algorithm. We demonstrate the imaging capabilities of this catheter with a printed paper phantom and in a section of dragon fruit.
Collapse
|
17
|
Schulz-Hildebrandt H, Pfeiffer T, Eixmann T, Lohmann S, Ahrens M, Rehra J, Draxinger W, König P, Huber R, Hüttmann G. High-speed fiber scanning endoscope for volumetric multi-megahertz optical coherence tomography. OPTICS LETTERS 2018; 43:4386-4389. [PMID: 30211870 DOI: 10.1364/ol.43.004386] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We present a forward-viewing fiber scanning endoscope (FSE) for high-speed volumetric optical coherence tomography (OCT). The reduction in size of the probe was achieved by substituting the focusing optics by an all-fiber-based imaging system which consists of a combination of scanning single-mode fibers, a glass spacer, made from a step-index multi-mode fiber, and a gradient-index fiber. A lateral resolution of 11 μm was achieved at a working distance of 1.2 mm. The newly designed piezo-based FSE has an outer diameter of 1.6 mm and a rigid length of 13.5 mm. By moving the whole imaging optic in spirals for scanning the sample, the beam quality remains constant over the entire field of view with a diameter of 0.8 mm. The scanning frequency was adjusted to 1.22 kHz for use with a 3.28 MHz Fourier domain mode locked OCT system. Densely sampled volumes have been imaged at a rate of 6 volumes per second.
Collapse
|
18
|
Liu R, Winkelmann JA, Spicer G, Zhu Y, Eid A, Ameer GA, Backman V, Yi J. Single capillary oximetry and tissue ultrastructural sensing by dual-band dual-scan inverse spectroscopic optical coherence tomography. LIGHT, SCIENCE & APPLICATIONS 2018; 7:57. [PMID: 30839641 PMCID: PMC6113297 DOI: 10.1038/s41377-018-0057-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 08/03/2018] [Accepted: 08/03/2018] [Indexed: 05/03/2023]
Abstract
Measuring capillary oxygenation and the surrounding ultrastructure can allow one to monitor a microvascular niche and better understand crucial biological mechanisms. However, capillary oximetry and pericapillary ultrastructure are challenging to measure in vivo. Here we demonstrate a novel optical imaging system, dual-band dual-scan inverse spectroscopic optical coherence tomography (D2-ISOCT), that, for the first time, can simultaneously obtain the following metrics in vivo using endogenous contrast: (1) capillary-level oxygen saturation and arteriolar-level blood flow rates, oxygen delivery rates, and oxygen metabolic rates; (2) spatial characteristics of tissue structures at length scales down to 30 nm; and (3) morphological images up to 2 mm in depth. To illustrate the capabilities of D2-ISOCT, we monitored alterations to capillaries and the surrounding pericapillary tissue (tissue between the capillaries) in the healing response of a mouse ear wound model. The obtained microvascular and ultrastructural metrics corroborated well with each other, showing the promise of D2-ISOCT for becoming a powerful new non-invasive imaging tool.
Collapse
Affiliation(s)
- Rongrong Liu
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - James A. Winkelmann
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Graham Spicer
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Yunxiao Zhu
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Aya Eid
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Guillermo A. Ameer
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Vadim Backman
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Ji Yi
- Department of Medicine, Boston University School of Medicine, Boston, MA 02118 USA
| |
Collapse
|