Hirsch E, Bornemissza Z, Nagy ZK, Marosi GJ, Farkas A. Quantitative and qualitative analysis of cell culture media powders for mammalian cells by Raman microscopy. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 310:123906. [PMID: 38277781 DOI: 10.1016/j.saa.2024.123906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 11/23/2023] [Accepted: 01/15/2024] [Indexed: 01/28/2024]
Abstract
Cell culture media are essential for large-scale recombinant protein production using mammalian cell cultures. The composition and quality of media significantly impact cell growth and product formation. Analyzing media poses challenges due to complex compositions and undisclosed exact compositions. Traditional methods like NMR and chromatography offer sensitivity but require time-consuming sample preparation and lack spatial information. Raman chemical mapping characterizes solids, but its use in cell culture media analysis is limited so far. We present a chemometric evaluation for Raman maps to qualify and quantify media components, evaluate powder homogeneity, and perform lot-to-lot comparisons. Three lots of a marketed cell culture media powder were measured with Raman mapping technique. Chemometrics techniques have outlined a strategy to extract information from complex data. First, a spectral library has been structured. In addition to the 23 spectra for presumed ingredients, we obtained another 9 pure components with Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS). Then the Spectral Angle Mapper-Orthogonal Projection (SAM-OP) algorithm revealed whether references actually occur in the mapped media powders. Finally, a quantification was provided by Classical Least Squares (CLS) modelling. Quantities of 18 significant amino acids mostly correlated with the reference method. The proposed method can be generally applied even for such complicated samples. Leveraging Raman mapping and innovative chemometric methods enhance recombinant protein production by improving the understanding of the spatial distribution and composition of cell culture media in mammalian cell cultivations.
Collapse
Affiliation(s)
- Edit Hirsch
- Department of Organic Chemistry and Technology, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Müegyetem rkp. 3., H-1111 Budapest, Hungary
| | - Zsuzsanna Bornemissza
- Department of Organic Chemistry and Technology, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Müegyetem rkp. 3., H-1111 Budapest, Hungary
| | - Zsombor K Nagy
- Department of Organic Chemistry and Technology, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Müegyetem rkp. 3., H-1111 Budapest, Hungary
| | - György J Marosi
- Department of Organic Chemistry and Technology, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Müegyetem rkp. 3., H-1111 Budapest, Hungary
| | - Attila Farkas
- Department of Organic Chemistry and Technology, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Müegyetem rkp. 3., H-1111 Budapest, Hungary.
| |
Collapse
|
2
|
Vivas CV, Duarte EL, Barreto YB, deOliveira CLP, Toma SH, Santos JJ, Araki K, Alencar AM, Bloise AC. Interactions Between Silver Nanoparticles and Culture Medium Biomolecules with Dose and Time Dependencies. J Fluoresc 2024:10.1007/s10895-023-03564-x. [PMID: 38183590 DOI: 10.1007/s10895-023-03564-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 12/20/2023] [Indexed: 01/08/2024]
Abstract
The interaction between silver nanoparticles (AgNPs) and molecules producing coronas plays a key role in cytotoxicity mechanisms. Once adsorbed coronas determine the destiny of nanomaterials in vivo, their effective deployment in the biomedical field requires a comprehensive understanding of the dynamic interactions of biomolecules with nanoparticles. In this work, we characterized 40 nm AgNPs in three different nutritional cell media at different molar concentrations and incubation times to study the binding mechanism of molecules on surface nanoparticles. In addition, their cytotoxic effects have been studied in three cell lineages used as tissue regeneration models: FN1, HUV-EC-C, RAW 264.7. According to the data, when biomolecules from DMEM medium were in contact with AgNPs, agglomeration and precipitation occurred. However, FBS medium proteins indicated the formation of coronas over the nanoparticles. Nonetheless, little adsorption of molecules around the nanoparticles was observed when compared to DMEM supplemented with 10% FBS. These findings indicate that when nanoparticles and bioproteins from supplemented media interact, inorganic salts from DMEM contribute to produce large bio-coronas, the size of which varies with the concentration and time. The static quenching mechanism was shown to be responsible for the fluorescence quenching of the bioprotein aggregates on the AgNPs surface. The calculated bioprotein-nanoparticle surface binding constants were on the order of 105 M-1 at 37 °C, with hydrophobic interactions driven by enthalpy and entropy playing a role, as confirmed by thermodynamic analysis. Cytotoxicity data showed a systematic degrowth in the viable cell population as the number of nanoparticles increased and the diameter of coronas decreased. Cytotoxic intervals associated with half decrease of cell population were established for AgNPs molar concentration of 75 µM for 24 h and 50 µM for 48 h. In summary, through the cytotoxicity mechanism of bio-coronas we are able to manipulate cells' expansion rates to promote specific processes, such inflammatory mechanisms, at different time instants.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Koiti Araki
- Instituto de Quimica, Universidade de Sao Paulo, Sao Paulo, Brazil
| | | | | |
Collapse
|
3
|
Kyne M, de Faria E Silva AL, Vickroy B, Ryder AG. Size exclusion chromatography for screening yeastolate used in cell culture media. J Biotechnol 2023; 376:1-10. [PMID: 37689251 DOI: 10.1016/j.jbiotec.2023.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 07/24/2023] [Accepted: 09/06/2023] [Indexed: 09/11/2023]
Abstract
Yeastolate is often used as a media supplement in industrial mammalian cell culture or as a major media component for microbial fermentations. Yeastolate variability can significantly affect process performance, but analysis is technically challenging because of its compositional complexity. However, what may be adequate for manufacturing purposes is a fast, inexpensive screening method to identify molecular variance and provide sufficient information for quality control purposes, without characterizing all the molecular components. Here we used Size Exclusion Chromatography (SEC) and chemometrics as a relatively fast screening method for identifying lot-to-lot variance (with Principal Component Analysis, PCA) and investigated if Partial Least Squares, PLS, predictive models which correlated SEC data with process titer could be obtained. SEC provided a relatively fast measure of gross molecular size hydrolysate variability with minimal sample preparation and relatively simple data analysis. The sample set comprised of 18 samples from 12 unique source lots of an ultra-filtered yeastolate (10 kDa molecular weight cut-off) used in a mammalian cell culture process. SEC showed significant lot-to-lot variation, at 214 and 280 nm detection, with the most significant variation, that correlated with process performance, occurring at a retention time of ∼6 min. PCA and PLS regression correlation models provided fast identification of yeastolate variance and its process impact. The primary drawback is the limited column lifetime (<300 injections) caused by the complex nature of yeastolate and the presence of zinc. This limited long term reproducibility because these age-related, non-linear changes in chromatogram peak positions and shapes were very significant.
Collapse
Affiliation(s)
- Michelle Kyne
- Nanoscale BioPhotonics Laboratory, University of Galway, H91 CF50 Galway, Ireland
| | | | - Bruce Vickroy
- Biopharmaceutical and Steriles Manufacturing Science and Technology, GlaxoSmithKline, 709 Swedeland Rd., King of Prussia, PA 19046, USA
| | - Alan G Ryder
- Nanoscale BioPhotonics Laboratory, University of Galway, H91 CF50 Galway, Ireland.
| |
Collapse
|
4
|
de Faria e Silva AL, Ryder AG. Analyzing protein conjugation reactions for antibody-drug conjugate synthesis using polarized excitation emission matrix spectroscopy. Biotechnol Bioeng 2022; 119:3432-3446. [PMID: 36071600 PMCID: PMC9828061 DOI: 10.1002/bit.28229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 08/23/2022] [Accepted: 09/02/2022] [Indexed: 01/12/2023]
Abstract
Antibody-drug conjugates (ADCs) are promising anticancer therapeutics, which offer important advantages compared to more classical therapies. There are a variety of ADC critical quality attributes (CQAs) such as the protein structure, aggregation, and drug-to-antibody ratio (DAR), which all impact on potency, stability, and toxicity. Production processes can destabilize antibodies via a variety of physical and chemical stresses, and or by increased aggregation after conjugation of hydrophobic drugs. Thus, a proper control strategy for handling, production, and storage is necessary to maintain CQA levels, which requires the use of in-process quality measurements to first identify, then understand, and control the variables which adversely affect ADC CQAs during manufacturing. Here, we show how polarized excitation emission matrix (pEEM) spectroscopy, a sensitive, nondestructive, and potentially fast technique, can be used for rapidly assessing aggregation and DAR in a single measurement. pEEM provides several sources of information for protein analysis: Rayleigh scatter for identifying aggregate/particle formation and fluorescence emission to assess chemical and structural changes induced by attachment of a linker and/or a small molecule drug payload. Here, we used a nontoxic ADC mimic (monoclonal antibody with linker molecule) to demonstrate efficacy of the measurement method. Emission changes caused via light absorption by the attached linker, allowed us to predict DAR with good accuracy using fluorescence signal from the final purified products (6% relative error of prediction [REP]) and also from unpurified alkylation intermediates (11% REP). pEEM changes could also be correlated with size (hydrodynamic radius, Rh ) and aggregate content parameters obtained from dynamic light scattering and size exclusion chromatography (SEC). For the starting material and purified product samples, pEEM correlated better with Rh (R2 = 0.99, 6% REP) than SEC determined aggregate content (18% REP). Combining both fluorescence and light scatter signals also enabled in-process size quantification (6% REP). Overall, combining polarized measurements with EEM and Rayleigh scatter provides a single measurement, multi-attribute test method for ADC manufacturing.
Collapse
Affiliation(s)
- Ana L. de Faria e Silva
- Nanoscale BioPhotonics Laboratory, School of ChemistryNational University of IrelandGalwayIreland
| | - Alan G. Ryder
- Nanoscale BioPhotonics Laboratory, School of ChemistryNational University of IrelandGalwayIreland
| |
Collapse
|
5
|
Chiappini FA, Azcarate S, Alcaraz MR, Forno ÁG, Goicoechea HC. Prospective inference of bioprocess cell viability through chemometric modeling of fluorescence multiway data. Biotechnol Prog 2021; 37:e3173. [PMID: 33969945 DOI: 10.1002/btpr.3173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 04/19/2021] [Accepted: 05/06/2021] [Indexed: 11/11/2022]
Abstract
In this investigation, the fermentation step of a standard mammalian cell-based industrial bioprocess for the production of a therapeutic protein was studied, with particular emphasis on the evolution of cell viability. This parameter constitutes one of the critical variables for bioprocess monitoring since it can affect downstream operations and the quality of the final product. In addition, when the cells experiment an unpredictable drop in viability, the assessment of this variable through classic off-line methods may not provide information sufficiently in advance to take corrective actions. In this context, Process Analytical Technology (PAT) framework aims to develop novel strategies for more efficient monitoring of critical variables, in order to improve the bioprocess performance. Thus, in this work, a set of chemometric tools were integrated to establish a PAT strategy to monitor cell viability, based on fluorescence multiway data obtained from fermentation samples of a particular bioprocess, in two different scales of operation. The spectral information, together with data regarding process variables, was integrated through chemometric exploratory tools to characterize the bioprocess and stablish novel criteria for the monitoring of cell viability. These findings motivated the development of a multivariate classification model, aiming to obtain predictive tools for the monitoring of future lots of the same bioprocess. The model could be satisfactorily fitted, showing the non-error rate of prediction of 100%.
Collapse
Affiliation(s)
- Fabricio A Chiappini
- Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, Santa Fe, Argentina.,Argentinian national institution of research, Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz, Argentina
| | - Silvana Azcarate
- Argentinian national institution of research, Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz, Argentina.,Facultad de Ciencias Exactas y Naturales, Universidad Nacional de La Pampa, Santa Rosa, Argentina
| | - Mirta R Alcaraz
- Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, Santa Fe, Argentina.,Argentinian national institution of research, Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz, Argentina
| | - Ángela G Forno
- Zelltek SA, Parque Tecnológico Litoral Centro - CCT Conicet Santa Fe (C1425FQB), Santa Fe, Argentina
| | - Hector C Goicoechea
- Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, Santa Fe, Argentina.,Argentinian national institution of research, Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz, Argentina
| |
Collapse
|
6
|
Boateng BO, Elcoroaristizabal S, Ryder AG. Development of a rapid polarized total synchronous fluorescence spectroscopy (pTSFS) method for protein quantification in a model bioreactor broth. Biotechnol Bioeng 2021; 118:1805-1817. [PMID: 33501639 DOI: 10.1002/bit.27694] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 01/07/2021] [Accepted: 01/21/2021] [Indexed: 12/22/2022]
Abstract
Protein quantification during bioprocess monitoring is essential for biopharmaceutical manufacturing and is complicated by the complex chemical composition of the bioreactor broth. Here we present the early-stage development and optimization of a polarized total synchronous fluorescence spectroscopy (pTSFS) method for protein quantification in a hydrolysate-protein model (mimics clarified bioreactor broth samples) using a standard benchtop laboratory fluorometer. We used UV transmitting polarizers to provide wider range pTSFS spectra for screening of the four different TSFS spectra generated by the measurement: parallel (||), perpendicular (⊥), unpolarized (T) intensity spectra and anisotropy maps. TSFS|| (parallel polarized) measurements were the best for protein quantification compared to standard unpolarized measurements and the Bradford assay. This was because TSFS|| spectra had a better analyte signal to noise ratio (SNR), due to the anisotropy of protein emission. This meant that protein signals were better resolved from the background emission of small molecule fluorophores in the cell culture media. SNR of >5000 was achieved for concentrations of bovine serum albumin/yeastolate 1.2/10 g L-1 with TSFS|| . Optimization using genetic algorithm and interval partial least squares based variable selection enabled reduction of spectral resolution and number of excitation wavelengths required without degrading performance. This enables fast (<3.5 min) online/at-line measurements, and the method had an LOD of 0.18 g L-1 and high accuracy with a predictive error of <9%.
Collapse
Affiliation(s)
- Bernard O Boateng
- Nanoscale BioPhotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland
| | - Saioa Elcoroaristizabal
- Nanoscale BioPhotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland
| | - Alan G Ryder
- Nanoscale BioPhotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland
| |
Collapse
|
7
|
Brunner M, Brosig P, Losing M, Kunzelmann M, Calvet A, Stiefel F, Bechmann J, Unsoeld A, Schaub J. Towards robust cell culture processes - Unraveling the impact of media preparation by spectroscopic online monitoring. Eng Life Sci 2020; 19:666-680. [PMID: 32624960 PMCID: PMC6999248 DOI: 10.1002/elsc.201900050] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 07/12/2019] [Accepted: 07/31/2019] [Indexed: 11/09/2022] Open
Abstract
Biopharmaceutical manufacturing processes can be affected by variability in cell culture media, e.g. caused by raw material impurities. Although efforts have been made in industry and academia to characterize cell culture media and raw materials with advanced analytics, the process of industrial cell culture media preparation itself has not been reported so far. Within this publication, we first compare mid-infrared and two-dimensional fluorescence spectroscopy with respect to their suitability as online monitoring tools during cell culture media preparation, followed by a thorough assessment of the impact of preparation parameters on media quality. Through the application of spectroscopic methods, we can show that media variability and its corresponding root cause can be detected online during the preparation process. This methodology is a powerful tool to avoid batch failure and is a valuable technology for media troubleshooting activities. Moreover, in a design of experiments approach, including additional liquid chromatography-mass spectrometry analytics, it is shown that variable preparation parameters such as temperature, power input and preparation time can have a strong impact on the physico-chemical composition of the media. The effect on cell culture process performance and product quality in subsequent fed-batch processes was also investigated. The presented results reveal the need for online spectroscopic methods during the preparation process and show that media variability can already be introduced by variation in media preparation parameters, with a potential impact on scale-up to a commercial manufacturing process.
Collapse
Affiliation(s)
- Matthias Brunner
- Bioprocess Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| | - Philipp Brosig
- Bioprocess Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| | - Monika Losing
- Bioprocess Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| | - Marco Kunzelmann
- Analytical Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| | - Amandine Calvet
- Bioprocess Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| | - Fabian Stiefel
- Bioprocess Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| | - Jan Bechmann
- Bioprocess Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| | - Andreas Unsoeld
- Bioprocess Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| | - Jochen Schaub
- Bioprocess Development Biologicals Boehringer Ingelheim Pharma GmbH & Co. KG Biberach Germany
| |
Collapse
|
8
|
Multi-attribute quality screening of immunoglobulin G using polarized Excitation Emission Matrix spectroscopy. Anal Chim Acta 2020; 1101:99-110. [DOI: 10.1016/j.aca.2019.12.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 12/05/2019] [Accepted: 12/08/2019] [Indexed: 12/20/2022]
|
9
|
Dickens J, Khattak S, Matthews TE, Kolwyck D, Wiltberger K. Biopharmaceutical raw material variation and control. Curr Opin Chem Eng 2018. [DOI: 10.1016/j.coche.2018.10.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
10
|
|
11
|
Melnikau D, Elcoroaristizabal S, Ryder AG. An excitation emission fluorescence lifetime spectrometer using a frequency doubled supercontinuum laser source. Methods Appl Fluoresc 2018; 6:045007. [PMID: 30101757 DOI: 10.1088/2050-6120/aad9ae] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The accurate fluorescence analysis of complex, multi-fluorophore containing proteins requires the use of multi-dimensional measurement techniques. For the measurement of intrinsic fluorescence from tyrosine (Tyr) and tryptophan (Trp) one needs tuneable UV excitation and for steady-state measurements like Excitation Emission Matrix (EEM) simple pulsed Xe lamps are commonly used. Unfortunately, simultaneous multi-dimensional wavelength and time resolved measurement of intrinsic protein fluorescence in the 260 to 400 nm spectral range are challenging and typically required the use of very complex tuneable laser systems or multiple single excitation wavelength sources. Here we have assembled and validated a novel Excitation Emission Fluorescence Lifetime Spectrometer (EEFLS) using a pulsed, frequency doubled, Super-Continuum Laser (SCL) source coupled with a 16 channel multi-anode Time Correlated Single Photon Counting (TCSPC) measurement system. This EEFLS enabled the collection of near complete lifetime and intensity maps over the most important intrinsic protein fluorescence spectral range (λ ex = 260-350/λ em = 300-500 nm). The 4-dimensional (λ ex/λ em/I(t)/τ) Excitation Emission Fluorescence Lifetime Matrix (EEFLM) data produced can be used to better characterize the complex intrinsic emission from proteins. The system was capable of measuring fluorescence emission data with high spectral (1-2 nm) resolution and had an Instrument Response Function (IRF) of ∼650 ps for accurate measurement of nanosecond lifetimes. UV power output was stable after a warm up period, with variations of <2% over 9 hours and reproducible (relative standard deviation RSD < 1.5%). This enabled the collection of accurate EEFLM data at low resolution (∼12 nm in excitation and emission) in 1-2 hours or high resolution (4 nm) in ∼17 hours. EEFLS performance in the UV was compared with a conventional commercial TCSPC system using pulsed LED excitation and validated using solutions of p-terphenyl and tryptophan.
Collapse
Affiliation(s)
- Dzmitry Melnikau
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland
| | | | | |
Collapse
|
12
|
Kumar K, Tarai M, Mishra AK. Unconventional steady-state fluorescence spectroscopy as an analytical technique for analyses of complex-multifluorophoric mixtures. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.09.004] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
13
|
Ryder AG, Stedmon CA, Harrit N, Bro R. Calibration, standardization, and quantitative analysis of multidimensional fluorescence (MDF) measurements on complex mixtures (IUPAC Technical Report). PURE APPL CHEM 2017. [DOI: 10.1515/pac-2017-0610] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
AbstractThis IUPAC Technical Report describes and compares the currently applied methods for the calibration and standardization of multi-dimensional fluorescence (MDF) spectroscopy data as well as recommendations on the correct use of chemometric methods for MDF data analysis. The paper starts with a brief description of the measurement principles for the most important MDF techniques and a short introduction to the most important applications. Recommendations are provided for instrument calibration, sample preparation and handling, and data collection, as well as the proper use of chemometric data analysis methods.
Collapse
Affiliation(s)
- Alan G. Ryder
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland
| | - Colin A. Stedmon
- National Institute for Aquatic Resources, Technical University of Denmark, DK-2800, Kgs.Lyngby, Denmark
| | - Niels Harrit
- Nanoscience Center, H. C. Ørsted Institute, Universitetsparken 5, University of Copenhagen, DK-2100, Copenhagen, Denmark
| | - Rasmus Bro
- Department Food Science, Faculty of Life Sciences, University Copenhagen, DK-1958, Frederiksberg, Denmark
| |
Collapse
|
14
|
Accurate anisotropy recovery from fluorophore mixtures using Multivariate Curve Resolution (MCR). Anal Chim Acta 2017; 1000:132-143. [PMID: 29289302 DOI: 10.1016/j.aca.2017.11.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Revised: 11/12/2017] [Accepted: 11/16/2017] [Indexed: 11/21/2022]
Abstract
Anisotropy resolved multidimensional emission spectroscopy (ARMES) provides valuable insights into multi-fluorophore systems like proteins that have complex overlapping emission bands. The method combines multidimensional fluorescence, anisotropy, and chemometrics to facilitate the differentiation of fluorophores with very similar emission properties. Here, we address the critical issue of standardizing the chemometric methods required to accurately extract spectral and anisotropy information from fluorophore mixtures using two standard sample sets: perylene in glycerol, and a mixture of Erythrosin B and Phloxine B with overlapping emission but different anisotropies. We show for the first time how to accurately model component anisotropy using Multivariate Curve Resolution (MCR) from data collected using total synchronous fluorescence scan (TSFS) and Excitation Emission Matrix (EEM) measurement methods. These datasets were selected to avoid the presence of inner filter effects (IFE) or Förster resonance energy transfer (FRET) that would depolarize fluorescence emission or reduce data tri-linearity. This allowed the non-trilinear TSFS data to yield accurate component anisotropy data once modelled using the correct data augmentation strategy, however, the EEM data proved to be more accurate once optimal constraints (non-negativity and correspondence among species) were employed. For perylene (S2) and Phloxine B which both have very weak anisotropy (<0.06), while the spectral recovery was excellent, the modelled anisotropy values were reasonably accurate (±20% of the real value) because of large relative noise contributions. However, for perylene (S1) and Erythrosin B which have large (>0.2) anisotropies, bilinear and trilinear EEM models built using a total tri-linearity constraint, yielded solutions without any rotational ambiguities and very accurate (±4% of real value) anisotropy values. These sample systems thus provide simple and robust test systems for validating the spectral measurement and chemometric data analysis elements of ARMES.
Collapse
|
15
|
Casamayou-Boucau Y, Ryder AG. Extended wavelength anisotropy resolved multidimensional emission spectroscopy (ARMES) measurements: better filters, validation standards, and Rayleigh scatter removal methods. Methods Appl Fluoresc 2017; 5:037001. [PMID: 28584197 DOI: 10.1088/2050-6120/aa7763] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Anisotropy resolved multidimensional emission spectroscopy (ARMES) provides valuable insights into multi-fluorophore proteins (Groza et al 2015 Anal. Chim. Acta 886 133-42). Fluorescence anisotropy adds to the multidimensional fluorescence dataset information about the physical size of the fluorophores and/or the rigidity of the surrounding micro-environment. The first ARMES studies used standard thin film polarizers (TFP) that had negligible transmission between 250 and 290 nm, preventing accurate measurement of intrinsic protein fluorescence from tyrosine and tryptophan. Replacing TFP with pairs of broadband wire grid polarizers enabled standard fluorescence spectrometers to accurately measure anisotropies between 250 and 300 nm, which was validated with solutions of perylene in the UV and Erythrosin B and Phloxine B in the visible. In all cases, anisotropies were accurate to better than ±1% when compared to literature measurements made with Glan Thompson or TFP polarizers. Better dual wire grid polarizer UV transmittance and the use of excitation-emission matrix measurements for ARMES required complete Rayleigh scatter elimination. This was achieved by chemometric modelling rather than classical interpolation, which enabled the acquisition of pure anisotropy patterns over wider spectral ranges. In combination, these three improvements permit the accurate implementation of ARMES for studying intrinsic protein fluorescence.
Collapse
Affiliation(s)
- Yannick Casamayou-Boucau
- Nanoscale BioPhotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland
| | | |
Collapse
|
16
|
Buckley K, Ryder AG. Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review. APPLIED SPECTROSCOPY 2017; 71:1085-1116. [PMID: 28534676 DOI: 10.1177/0003702817703270] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The production of active pharmaceutical ingredients (APIs) is currently undergoing its biggest transformation in a century. The changes are based on the rapid and dramatic introduction of protein- and macromolecule-based drugs (collectively known as biopharmaceuticals) and can be traced back to the huge investment in biomedical science (in particular in genomics and proteomics) that has been ongoing since the 1970s. Biopharmaceuticals (or biologics) are manufactured using biological-expression systems (such as mammalian, bacterial, insect cells, etc.) and have spawned a large (>€35 billion sales annually in Europe) and growing biopharmaceutical industry (BioPharma). The structural and chemical complexity of biologics, combined with the intricacy of cell-based manufacturing, imposes a huge analytical burden to correctly characterize and quantify both processes (upstream) and products (downstream). In small molecule manufacturing, advances in analytical and computational methods have been extensively exploited to generate process analytical technologies (PAT) that are now used for routine process control, leading to more efficient processes and safer medicines. In the analytical domain, biologic manufacturing is considerably behind and there is both a huge scope and need to produce relevant PAT tools with which to better control processes, and better characterize product macromolecules. Raman spectroscopy, a vibrational spectroscopy with a number of useful properties (nondestructive, non-contact, robustness) has significant potential advantages in BioPharma. Key among them are intrinsically high molecular specificity, the ability to measure in water, the requirement for minimal (or no) sample pre-treatment, the flexibility of sampling configurations, and suitability for automation. Here, we review and discuss a representative selection of the more important Raman applications in BioPharma (with particular emphasis on mammalian cell culture). The review shows that the properties of Raman have been successfully exploited to deliver unique and useful analytical solutions, particularly for online process monitoring. However, it also shows that its inherent susceptibility to fluorescence interference and the weakness of the Raman effect mean that it can never be a panacea. In particular, Raman-based methods are intrinsically limited by the chemical complexity and wide analyte-concentration-profiles of cell culture media/bioprocessing broths which limit their use for quantitative analysis. Nevertheless, with appropriate foreknowledge of these limitations and good experimental design, robust analytical methods can be produced. In addition, new technological developments such as time-resolved detectors, advanced lasers, and plasmonics offer potential of new Raman-based methods to resolve existing limitations and/or provide new analytical insights.
Collapse
Affiliation(s)
- Kevin Buckley
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland - Galway, Galway, Ireland
| | - Alan G Ryder
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland - Galway, Galway, Ireland
| |
Collapse
|
17
|
Wang W, Wu Z, Zhao J, Lui H, Zeng H. A rapid excitation-emission matrix fluorometer utilizing supercontinuum white light and acousto-optic tunable filters. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:063117. [PMID: 27370436 DOI: 10.1063/1.4954502] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Scanning speed and coupling efficiency of excitation light to optic fibres are two major technical challenges that limit the potential of fluorescence excitation-emission matrix (EEM) spectrometer for on-line applications and in vivo studies. In this paper, a novel EEM system, utilizing a supercontinuum white light source and acousto-optic tunable filters (AOTFs), was introduced and evaluated. The supercontinuum white light, generated by pumping a nonlinear photonic crystal fiber with an 800 nm femtosecond laser, was efficiently coupled into a bifurcated optic fiber bundle. High speed EEM spectral scanning was achieved using AOTFs both for selecting excitation wavelength and scanning emission spectra. Using calibration lamps (neon and mercury argon), wavelength deviations were determined to vary from 0.18 nm to -0.70 nm within the spectral range of 500-850 nm. Spectral bandwidth for filtered excitation light broadened by twofold compared to that measured with monochromatic light between 650 nm and 750 nm. The EEM spectra for methanol solutions of laser dyes were successfully acquired with this rapid fluorometer using an integration time of 5 s.
Collapse
Affiliation(s)
- Wenbo Wang
- Imaging Unit, Integrative Oncology Department, BC Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
| | - Zhenguo Wu
- Imaging Unit, Integrative Oncology Department, BC Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
| | - Jianhua Zhao
- Imaging Unit, Integrative Oncology Department, BC Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
| | - Harvey Lui
- Imaging Unit, Integrative Oncology Department, BC Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
| | - Haishan Zeng
- Imaging Unit, Integrative Oncology Department, BC Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
| |
Collapse
|
18
|
Groza RC, Li B, Ryder AG. Anisotropy resolved multidimensional emission spectroscopy (ARMES): A new tool for protein analysis. Anal Chim Acta 2015; 886:133-42. [PMID: 26320645 DOI: 10.1016/j.aca.2015.06.011] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Revised: 06/02/2015] [Accepted: 06/04/2015] [Indexed: 01/23/2023]
Abstract
Structural analysis of proteins using the emission of intrinsic fluorophores is complicated by spectral overlap. Anisotropy resolved multidimensional emission spectroscopy (ARMES) overcame the overlap problem by the use of anisotropy, with chemometric analysis, to better resolve emission from different fluorophores. Total synchronous fluorescence scan (TSFS) provided information about all the fluorophores that contributed to emission while anisotropy provided information about the environment of each fluorophore. Here the utility of ARMES was demonstrated via study of the chemical and thermal denaturation of human serum albumin (HSA). Multivariate curve resolution (MCR) analysis of the constituent polarized emission ARMES data resolved contributions from four emitters: fluorescence from tryptophan (Trp), solvent exposed tyrosine (Tyr), Tyr in a hydrophobic environment, and room temperature phosphorescence (RTP) from Trp. The MCR scores, anisotropy, and literature validated these assignments and showed all the expected transitions during HSA unfolding. This new methodology for comprehensive intrinsic fluorescence analysis of proteins is applicable to any protein containing multiple fluorophores.
Collapse
Affiliation(s)
- Radu Constantin Groza
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Galway, Ireland
| | - Boyan Li
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Galway, Ireland
| | - Alan G Ryder
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Galway, Ireland.
| |
Collapse
|
19
|
|
20
|
|
21
|
Calvet A, Ryder AG. Monitoring cell culture media degradation using surface enhanced Raman scattering (SERS) spectroscopy. Anal Chim Acta 2014; 840:58-67. [DOI: 10.1016/j.aca.2014.06.021] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Revised: 05/30/2014] [Accepted: 06/02/2014] [Indexed: 11/26/2022]
|
22
|
Groza RC, Calvet A, Ryder AG. A fluorescence anisotropy method for measuring protein concentration in complex cell culture media. Anal Chim Acta 2014; 821:54-61. [PMID: 24703214 DOI: 10.1016/j.aca.2014.03.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Revised: 03/06/2014] [Accepted: 03/07/2014] [Indexed: 01/09/2023]
Abstract
The rapid, quantitative analysis of the complex cell culture media used in biopharmaceutical manufacturing is of critical importance. Requirements for cell culture media composition profiling, or changes in specific analyte concentrations (e.g. amino acids in the media or product protein in the bioprocess broth) often necessitate the use of complicated analytical methods and extensive sample handling. Rapid spectroscopic methods like multi-dimensional fluorescence (MDF) spectroscopy have been successfully applied for the routine determination of compositional changes in cell culture media and bioprocess broths. Quantifying macromolecules in cell culture media is a specific challenge as there is a need to implement measurements rapidly on the prepared media. However, the use of standard fluorescence spectroscopy is complicated by the emission overlap from many media components. Here, we demonstrate how combining anisotropy measurements with standard total synchronous fluorescence spectroscopy (TSFS) provides a rapid, accurate quantitation method for cell culture media. Anisotropy provides emission resolution between large and small fluorophores while TSFS provides a robust measurement space. Model cell culture media was prepared using yeastolate (2.5 mg mL(-1)) spiked with bovine serum albumin (0 to 5 mg mL(-1)). Using this method, protein emission is clearly discriminated from background yeastolate emission, allowing for accurate bovine serum albumin (BSA) quantification over a 0.1 to 4.0 mg mL(-1) range with a limit of detection (LOD) of 13.8 μg mL(-1).
Collapse
Affiliation(s)
- Radu Constantin Groza
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland
| | - Amandine Calvet
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland
| | - Alan G Ryder
- Nanoscale Biophotonics Laboratory, School of Chemistry, National University of Ireland, Galway, Ireland.
| |
Collapse
|
23
|
Calvet A, Li B, Ryder AG. A rapid fluorescence based method for the quantitative analysis of cell culture media photo-degradation. Anal Chim Acta 2014; 807:111-9. [DOI: 10.1016/j.aca.2013.11.028] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2013] [Revised: 10/31/2013] [Accepted: 11/14/2013] [Indexed: 10/26/2022]
|
24
|
Li B, Shanahan M, Calvet A, Leister KJ, Ryder AG. Comprehensive, quantitative bioprocess productivity monitoring using fluorescence EEM spectroscopy and chemometrics. Analyst 2014; 139:1661-71. [DOI: 10.1039/c4an00007b] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Using fluorescence excitation-emission matrix spectroscopy and chemometric methods we demonstrate an effective and rapid method for quantitative monitoring of a mammalian cell culture based manufacturing process.
Collapse
Affiliation(s)
- Boyan Li
- Nanoscale Biophotonics Laboratory
- School of Chemistry
- National University of Ireland
- Galway, Ireland
| | - Michael Shanahan
- Nanoscale Biophotonics Laboratory
- School of Chemistry
- National University of Ireland
- Galway, Ireland
| | - Amandine Calvet
- Nanoscale Biophotonics Laboratory
- School of Chemistry
- National University of Ireland
- Galway, Ireland
| | - Kirk J. Leister
- Bristol-Myers Squibb
- Process Analytical Sciences
- Syracuse, USA
| | - Alan G. Ryder
- Nanoscale Biophotonics Laboratory
- School of Chemistry
- National University of Ireland
- Galway, Ireland
| |
Collapse
|
25
|
Kumar K, Mishra AK. Analysis of dilute aqueous multifluorophoric mixtures using excitation-emission matrix fluorescence (EEMF) and total synchronous fluorescence (TSF) spectroscopy: a comparative evaluation. Talanta 2013; 117:209-20. [PMID: 24209332 DOI: 10.1016/j.talanta.2013.09.002] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2013] [Revised: 08/31/2013] [Accepted: 09/02/2013] [Indexed: 10/26/2022]
Abstract
Excitation-emission matrix fluorescence (EEMF) and total synchronous fluorescence (TSF) spectroscopy are two conceptually different fluorescence techniques that have been used to map the fluorescence responses of the fluorophores present in a multifluorophoric mixture. EEMF was introduced four decades back and most of the fluorimeters have the suitable computer program which allows the acquisition EEMF spectra. Recently introduced TSF spectroscopy has been shown to possess good application potential in analytical fluorimetry and has started attracting the attention of analytical chemists. TSF data structure, however, is intrinsically different from EEMF data structure and a better understanding of TSF data structure is crucial to utilising its application potential. In the present work, a comprehensive comparative study between EEMF and TSF spectroscopic data set was performed by taking aqueous mixtures containing low concentrations of benzo[a]pyrene, chrysene, and pyrene as test case. The EEMF and TSF data structures were clearly explained by taking pyrene as an example. The effects of Rayleigh and Raman scattering on the quality of EEMF and TSF data sets were studied. EEMF and TSF data sets of dilute aqueous mixtures of benzo[a]pyrene, chrysene, and pyrene were subjected to three chemometric techniques PARAFAC, N-PLS, and MCR-ALS analysis. TSF data set in particular was found to be highly attuned to MCR-ALS analysis. Obtained results of chemometric analyses on EEMF and TSF data sets show that TSF data of dilute aqueous mixtures provides more accurate spectral and concentration information than EEMF data sets. Therefore, TSF spectroscopy could be considered as an alternate to the EEMF for the analyses of dilute multifluorophoric mixtures.
Collapse
Affiliation(s)
- Keshav Kumar
- Department of Chemistry, Indian Institute of Technology-Madras, Chennai-600036, India
| | | |
Collapse
|
26
|
Rapid quantification of tryptophan and tyrosine in chemically defined cell culture media using fluorescence spectroscopy. J Pharm Biomed Anal 2012; 71:89-98. [DOI: 10.1016/j.jpba.2012.08.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2012] [Revised: 08/01/2012] [Accepted: 08/05/2012] [Indexed: 11/19/2022]
|