van Osta N, van den Acker G, van Loon T, Arts T, Delhaas T, Lumens J. Numerical accuracy of closed-loop steady state in a zero-dimensional cardiovascular model. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2025; 383:20240208. [PMID: 40172559 PMCID: PMC11963903 DOI: 10.1098/rsta.2024.0208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2024] [Revised: 01/27/2025] [Accepted: 01/28/2025] [Indexed: 04/04/2025]
Abstract
Closed-loop cardiovascular models are becoming vital tools in clinical settings, making their accuracy and reliability paramount. While these models rely heavily on steady-state simulations, accuracy because of steady-state convergence is often assumed negligible. Using a reduced-order cardiovascular model created with the CircAdapt framework as a case study, we investigated steady-state convergence behaviour across various integration methods and simulation protocols. To minimize the effect of numerical errors, we first quantified the numerical errors originating from integration methods and model assumptions. We subsequently investigate this steady-state convergence error under two distinct conditions: first without, and then with homeostatic pressure-flow control (PFC), providing a comprehensive assessment of the CircAdapt framework's numerical stability and accuracy. Our results demonstrated that achieving a clinically accurate steady state required 7-15 heartbeats in simulations without regulatory mechanisms. When homeostatic control mechanisms were included to regulate mean arterial pressure and blood volume, more than twice the number of heartbeats was needed. By simulating a variable number of heartbeats tailored to each simulation's characteristics, an efficient balance between computational cost and steady-state accuracy can be achieved. Understanding this balance is crucial as cardiovascular models progress towards clinical use.This article is part of the theme issue 'Uncertainty quantification for healthcare and biological systems (Part 2)'.
Collapse
Affiliation(s)
- Nick van Osta
- Department of Biomedical Engineering, Cardiovascular Research Center Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Gitte van den Acker
- Department of Biomedical Engineering, Cardiovascular Research Center Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Tim van Loon
- Department of Biomedical Engineering, Cardiovascular Research Center Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Theo Arts
- Department of Biomedical Engineering, Cardiovascular Research Center Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Tammo Delhaas
- Department of Biomedical Engineering, Cardiovascular Research Center Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Joost Lumens
- Department of Biomedical Engineering, Cardiovascular Research Center Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| |
Collapse
|
2
|
Rodero C, Niederer SA. Striking the balance: Complexity, simplicity, and credibility in mathematical biology. Proc Natl Acad Sci U S A 2025; 122:e2504067122. [PMID: 40127282 PMCID: PMC12002325 DOI: 10.1073/pnas.2504067122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2025] Open
Affiliation(s)
- Cristobal Rodero
- Cardiac Electro-Mechanics Research Group, Faculty of Medicine, Imperial Centre for Translational and Experimental Medicine, National Heart and Lung Institute, Imperial College London, LondonW12 0NN, United Kingdom
| | - Steven A. Niederer
- Cardiac Electro-Mechanics Research Group, Faculty of Medicine, Imperial Centre for Translational and Experimental Medicine, National Heart and Lung Institute, Imperial College London, LondonW12 0NN, United Kingdom
- Turing Research and Innovation Cluster in Digital Twins, The Alan Turing Institute, LondonNW1 2DB, United Kingdom
| |
Collapse
|
3
|
Kimpton LM, Paun LM, Colebank MJ, Volodina V. Challenges and opportunities in uncertainty quantification for healthcare and biological systems. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2025; 383:20240232. [PMID: 40078151 PMCID: PMC11904623 DOI: 10.1098/rsta.2024.0232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2024] [Revised: 10/22/2024] [Accepted: 11/13/2024] [Indexed: 03/14/2025]
Abstract
Uncertainty quantification (UQ) is an essential aspect of computational modelling and statistical prediction. Multiple applications, including geophysics, climate science and aerospace engineering, incorporate UQ in the development and translation of new technologies. In contrast, the application of UQ to biological and healthcare models is understudied and suffers from several critical knowledge gaps. In an era of personalized medicine, patient-specific modelling, and digital twins, a lack of UQ understanding and appropriate implementation of UQ methodology limits the success of modelling and simulation in a clinical setting. The main contribution of our review article is to emphasize the importance and current deficiencies of UQ in the development of computational frameworks for healthcare and biological systems. As the introduction to the special issue on this topic, we provide an overview of UQ methodologies, their applications in non-biological and biological systems and the current gaps and opportunities for UQ development, as later highlighted by authors publishing in the special issue.This article is part of the theme issue 'Uncertainty quantification for healthcare and biological systems (Part 1)'.
Collapse
Affiliation(s)
- Louise M Kimpton
- Department of Mathematics and Statistics, University of Exeter, Exeter, UK
| | - L Mihaela Paun
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK
- School of Mathematical Sciences, University of Southampton, Southampton, UK
| | - Mitchel J Colebank
- Department of Biomedical Engineering, Edwards Lifesciences Foundation Cardiovascular Innovation and Research Center, University of California, Irvine, CA, USA
- Department of Mathematics, University of South Carolina, Columbia, SC, USA
| | - Victoria Volodina
- Department of Mathematics and Statistics, University of Exeter, Exeter, UK
| |
Collapse
|
4
|
Gillette K, Winkler B, Kurath-Koller S, Scherr D, Vigmond EJ, Bär M, Plank G. A computational study on the influence of antegrade accessory pathway location on the 12-lead electrocardiogram in Wolff-Parkinson-White syndrome. Europace 2025; 27:euae223. [PMID: 39259657 PMCID: PMC11879338 DOI: 10.1093/europace/euae223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 07/31/2024] [Accepted: 08/20/2024] [Indexed: 09/13/2024] Open
Abstract
AIMS Wolff-Parkinson-White (WPW) syndrome is a cardiovascular disease characterized by abnormal atrioventricular conduction facilitated by accessory pathways (APs). Invasive catheter ablation of the AP represents the primary treatment modality. Accurate localization of APs is crucial for successful ablation outcomes, but current diagnostic algorithms based on the 12-lead electrocardiogram (ECG) often struggle with precise determination of AP locations. In order to gain insight into the mechanisms underlying localization failures observed in current diagnostic algorithms, we employ a virtual cardiac model to elucidate the relationship between AP location and ECG morphology. METHODS AND RESULTS We first introduce a cardiac model of electrophysiology that was specifically tailored to represent antegrade APs in the form of a short atrioventricular bypass tract. Locations of antegrade APs were then automatically swept across both ventricles in the virtual model to generate a synthetic ECG database consisting of 9271 signals. Regional grouping of antegrade APs revealed overarching morphological patterns originating from diverse cardiac regions. We then applied variance-based sensitivity analysis relying on polynomial chaos expansion on the ECG database to mathematically quantify how variation in AP location and timing relates to morphological variation in the 12-lead ECG. We utilized our mechanistic virtual model to showcase the limitations of AP localization using standard ECG-based algorithms and provide mechanistic explanations through exemplary simulations. CONCLUSION Our findings highlight the potential of virtual models of cardiac electrophysiology not only to deepen our understanding of the underlying mechanisms of WPW syndrome but also to potentially enhance the diagnostic accuracy of ECG-based algorithms and facilitate personalized treatment planning.
Collapse
Affiliation(s)
- Karli Gillette
- Division of Biophysics and Medical Physics, Gottfried Schatz Research Center, Medical University of Graz, Neue Stiftingtalstraße 6, 8010 Graz, Austria
- BioTechMed-Graz, Mozartgasse 12/II, 8010 Graz, Austria
| | - Benjamin Winkler
- Physikalisch-Technische Bundesanstalt, National Metrology Institute, Berlin, Germany
| | - Stefan Kurath-Koller
- Division of Pediatric Cardiology, Department of Pediatrics, Medical University of Graz, Graz, Austria
| | - Daniel Scherr
- Department of Cardiology, Medical University of Graz, Graz, Austria
| | - Edward J Vigmond
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation University Bordeaux, Pessac-Bordeaux, France
- Institute of Mathematics of Bordeaux, UMR 5251, University Bordeaux, Talence, France
| | - Markus Bär
- Physikalisch-Technische Bundesanstalt, National Metrology Institute, Berlin, Germany
| | - Gernot Plank
- Division of Biophysics and Medical Physics, Gottfried Schatz Research Center, Medical University of Graz, Neue Stiftingtalstraße 6, 8010 Graz, Austria
- BioTechMed-Graz, Mozartgasse 12/II, 8010 Graz, Austria
| |
Collapse
|
5
|
Martinez-Navarro H, Zhou X, Rodriguez B. Mechanisms and Implications of Electrical Heterogeneity in Cardiac Function in Ischemic Heart Disease. Annu Rev Physiol 2025; 87:25-51. [PMID: 39541224 DOI: 10.1146/annurev-physiol-042022-020541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2024]
Abstract
A healthy heart shows intrinsic electrical heterogeneities that play a significant role in cardiac activation and repolarization. However, cardiac diseases may perturb the baseline electrical properties of the healthy cardiac tissue, leading to increased arrhythmic risk and compromised cardiac functions. Moreover, biological variability among patients produces a wide range of clinical symptoms, which complicates the treatment and diagnosis of cardiac diseases. Ischemic heart disease is usually caused by a partial or complete blockage of a coronary artery. The onset of the disease begins with myocardial ischemia, which can develop into myocardial infarction if it persists for an extended period. The progressive regional tissue remodeling leads to increased electrical heterogeneities, with adverse consequences on arrhythmic risk, cardiac mechanics, and mortality. This review aims to summarize the key role of electrical heterogeneities in the heart on cardiac function and diseases. Ischemic heart disease has been chosen as an example to show how adverse electrical remodeling at different stages may lead to variable manifestations in patients. For this, we have reviewed the dynamic electrophysiological and structural remodeling from the onset of acute myocardial ischemia and reperfusion to acute and chronic stages post-myocardial infarction. The arrhythmic mechanisms, patient phenotypes, risk stratification at different stages, and patient management strategies are also discussed. Finally, we provide a brief review on how computational approaches incorporate human electrophysiological heterogeneity to facilitate basic and translational research.
Collapse
Affiliation(s)
- Hector Martinez-Navarro
- Department of Computer Science, British Heart Foundation Centre of Research Excellence, University of Oxford, Oxford, United Kingdom; , ,
| | - Xin Zhou
- Department of Computer Science, British Heart Foundation Centre of Research Excellence, University of Oxford, Oxford, United Kingdom; , ,
| | - Blanca Rodriguez
- Department of Computer Science, British Heart Foundation Centre of Research Excellence, University of Oxford, Oxford, United Kingdom; , ,
| |
Collapse
|
6
|
Gray RA. A probabilistic modeling framework for the prediction of spontaneous premature beats and reentry initiation. Heart Rhythm 2025:S1547-5271(25)00004-9. [PMID: 39788177 DOI: 10.1016/j.hrthm.2024.12.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2024] [Revised: 12/18/2024] [Accepted: 12/28/2024] [Indexed: 01/12/2025]
Abstract
BACKGROUND Spontaneously occurring life-threatening reentrant arrhythmias result when a propagating premature beat encounters a region with significant dispersion of refractoriness. Although localized structural tissue heterogeneities and prescribed cell functional gradients have been incorporated into computational electrophysiologic models, a quantitative framework for the evolution from normal to abnormal behavior that occurs by disease is lacking. OBJECTIVE The purpose of this study was to develop a probabilistic modeling framework representing the complex interplay of cell function and tissue structure in health and disease that predicts the emergence of premature beats and the initiation of reentry. METHODS An action potential model of the rabbit was developed with data-driven uncertainty characterization as done previously. A novel tissue model using the discrete-cell monodomain equations was developed by implementing cellular uncertainty as a random spatial field. RESULTS Cellular action potentials exhibited a wide range of duration and even a variety of behaviors, with 67% exhibiting normal repolarization, 27% displaying early afterdepolarizations, and 6% showing repolarization failure. Nevertheless, simulations in tissue resulted in localized synchronized repolarization. Thus, cellular variability provided "tissue-level robustness," and premature beats and reentry induction were never observed even with abnormalities in cell function (IKr block) or tissue structure (increased tissue resistance). Alterations of both cell function and tissue structure were necessary for the generation of premature beats and arrhythmia initiation. CONCLUSION Once extended to whole hearts and validated for a specific context, this modeling framework provides a means to predict the probability of the initiation of life-threatening arrhythmias.
Collapse
Affiliation(s)
- Richard A Gray
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland.
| |
Collapse
|
7
|
Mondéjar-Parreño G, Sánchez-Pérez P, Cruz FM, Jalife J. Promising tools for future drug discovery and development in antiarrhythmic therapy. Pharmacol Rev 2025; 77:100013. [PMID: 39952687 DOI: 10.1124/pharmrev.124.001297] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 08/30/2024] [Accepted: 10/04/2024] [Indexed: 01/22/2025] Open
Abstract
Arrhythmia refers to irregularities in the rate and rhythm of the heart, with symptoms spanning from mild palpitations to life-threatening arrhythmias and sudden cardiac death. The complex molecular nature of arrhythmias complicates the selection of appropriate treatment. Current therapies involve the use of antiarrhythmic drugs (class I-IV) with limited efficacy and dangerous side effects and implantable pacemakers and cardioverter-defibrillators with hardware-related complications and inappropriate shocks. The number of novel antiarrhythmic drugs in the development pipeline has decreased substantially during the last decade and underscores uncertainties regarding future developments in this field. Consequently, arrhythmia treatment poses significant challenges, prompting the need for alternative approaches. Remarkably, innovative drug discovery and development technologies show promise in helping advance antiarrhythmic therapies. In this article, we review unique characteristics and the transformative potential of emerging technologies that offer unprecedented opportunities for transitioning from traditional antiarrhythmics to next-generation therapies. We assess stem cell technology, emphasizing the utility of innovative cell profiling using multiomics, high-throughput screening, and advanced computational modeling in developing treatments tailored precisely to individual genetic and physiological profiles. We offer insights into gene therapy, peptide, and peptibody approaches for drug delivery. We finally discuss potential strengths and weaknesses of such techniques in reducing adverse effects and enhancing overall treatment outcomes, leading to more effective, specific, and safer therapies. Altogether, this comprehensive overview introduces innovative avenues for personalized rhythm therapy, with particular emphasis on drug discovery, aiming to advance the arrhythmia treatment landscape and the prevention of sudden cardiac death. SIGNIFICANCE STATEMENT: Arrhythmias and sudden cardiac death account for 15%-20% of deaths worldwide. However, current antiarrhythmic therapies are ineffective and have dangerous side effects. Here, we review the field of arrhythmia treatment underscoring the slow progress in advancing the cardiac rhythm therapy pipeline and the uncertainties regarding evolution of this field. We provide information on how emerging technological and experimental tools can help accelerate progress and address the limitations of antiarrhythmic drug discovery.
Collapse
Affiliation(s)
| | | | | | - José Jalife
- Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain; CIBER de Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain; Department of Medicine, University of Michigan, Ann Arbor, Michigan; Department of Molecular and Integrative Physiology, University of Michigan, Ann Arbor, Michigan.
| |
Collapse
|
8
|
Kaboudian A, Gray RA, Uzelac I, Cherry EM, Fenton FH. Fast interactive simulations of cardiac electrical activity in anatomically accurate heart structures by compressing sparse uniform cartesian grids. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 257:108456. [PMID: 39476551 PMCID: PMC11581144 DOI: 10.1016/j.cmpb.2024.108456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 09/22/2024] [Accepted: 10/03/2024] [Indexed: 11/16/2024]
Abstract
BACKGROUND AND OBJECTIVE Numerical simulations are valuable tools for studying cardiac arrhythmias. Not only do they complement experimental studies, but there is also an increasing expectation for their use in clinical applications to guide patient-specific procedures. However, numerical studies that solve the reaction-diffusion equations describing cardiac electrical activity remain challenging to set up, are time-consuming, and in many cases, are prohibitively computationally expensive for long studies. The computational cost of cardiac simulations of complex models on anatomically accurate structures necessitates parallel computing. Graphics processing units (GPUs), which have thousands of cores, have been introduced as a viable technology for carrying out fast cardiac simulations, sometimes including real-time interactivity. Our main objective is to increase the performance and accuracy of such GPU implementations while conserving computational resources. METHODS In this work, we present a compression algorithm that can be used to conserve GPU memory and improve efficiency by managing the sparsity that is inherent in using Cartesian grids to represent cardiac structures directly obtained from high-resolution MRI and mCT scans. Furthermore, we present a discretization scheme that includes the cross-diagonal terms in the computational cell to increase numerical accuracy, which is especially important for simulating thin tissue sections without the need for costly mesh refinement. RESULTS Interactive WebGL simulations of atrial/ventricular structures (on PCs, laptops, tablets, and phones) demonstrate the algorithm's ability to reduce memory demand by an order of magnitude and achieve calculations up to 20x faster. We further showcase its superiority in slender tissues and validate results against experiments performed in live explanted human hearts. CONCLUSIONS In this work, we present a compression algorithm that accelerates electrical activity simulations on realistic anatomies by an order of magnitude (up to 20x), thereby allowing the use of finer grid resolutions while conserving GPU memory. Additionally, improved accuracy is achieved through cross-diagonal terms, which are essential for thin tissues, often found in heart structures such as pectinate muscles and trabeculae, as well as Purkinje fibers. Our method enables interactive simulations with even interactive domain boundary manipulation (unlike finite element/volume methods). Finally, agreement with experiments and ease of mesh import into WebGL paves the way for virtual cohorts and digital twins, aiding arrhythmia analysis and personalized therapies.
Collapse
Affiliation(s)
- Abouzar Kaboudian
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USA.
| | - Richard A Gray
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USA
| | - Ilija Uzelac
- School of Physics, Georgia Institute of Technology, Atlanta, GA, USA; School of Medicine, Virginia Commonwealth University, Richmond, VA, USA
| | - Elizabeth M Cherry
- School of Computational Science and Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Flavio H Fenton
- School of Physics, Georgia Institute of Technology, Atlanta, GA, USA
| |
Collapse
|
9
|
Sel K, Osman D, Zare F, Masoumi Shahrbabak S, Brattain L, Hahn J, Inan OT, Mukkamala R, Palmer J, Paydarfar D, Pettigrew RI, Quyyumi AA, Telfer B, Jafari R. Building Digital Twins for Cardiovascular Health: From Principles to Clinical Impact. J Am Heart Assoc 2024; 13:e031981. [PMID: 39087582 PMCID: PMC11681439 DOI: 10.1161/jaha.123.031981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/02/2024]
Abstract
The past several decades have seen rapid advances in diagnosis and treatment of cardiovascular diseases and stroke, enabled by technological breakthroughs in imaging, genomics, and physiological monitoring, coupled with therapeutic interventions. We now face the challenge of how to (1) rapidly process large, complex multimodal and multiscale medical measurements; (2) map all available data streams to the trajectories of disease states over the patient's lifetime; and (3) apply this information for optimal clinical interventions and outcomes. Here we review new advances that may address these challenges using digital twin technology to fulfill the promise of personalized cardiovascular medical practice. Rooted in engineering mechanics and manufacturing, the digital twin is a virtual representation engineered to model and simulate its physical counterpart. Recent breakthroughs in scientific computation, artificial intelligence, and sensor technology have enabled rapid bidirectional interactions between the virtual-physical counterparts with measurements of the physical twin that inform and improve its virtual twin, which in turn provide updated virtual projections of disease trajectories and anticipated clinical outcomes. Verification, validation, and uncertainty quantification builds confidence and trust by clinicians and patients in the digital twin and establishes boundaries for the use of simulations in cardiovascular medicine. Mechanistic physiological models form the fundamental building blocks of the personalized digital twin that continuously forecast optimal management of cardiovascular health using individualized data streams. We present exemplars from the existing body of literature pertaining to mechanistic model development for cardiovascular dynamics and summarize existing technical challenges and opportunities pertaining to the foundation of a digital twin.
Collapse
Affiliation(s)
- Kaan Sel
- Laboratory for Information & Decision Systems (LIDS)Massachusetts Institute of TechnologyCambridgeMAUSA
| | - Deen Osman
- Department of Electrical and Computer EngineeringTexas A&M UniversityCollege StationTXUSA
| | - Fatemeh Zare
- Department of Electrical and Computer EngineeringTexas A&M UniversityCollege StationTXUSA
| | | | - Laura Brattain
- Lincoln LaboratoryMassachusetts Institute of TechnologyLexingtonMAUSA
| | - Jin‐Oh Hahn
- Department of Mechanical EngineeringUniversity of MarylandCollege ParkMDUSA
| | - Omer T. Inan
- School of Electrical and Computer EngineeringGeorgia Institute of TechnologyAtlantaGAUSA
| | - Ramakrishna Mukkamala
- Department of Bioengineering and Anesthesiology and Perioperative MedicineUniversity of PittsburghPittsburghPAUSA
| | - Jeffrey Palmer
- Lincoln LaboratoryMassachusetts Institute of TechnologyLexingtonMAUSA
| | - David Paydarfar
- Department of NeurologyThe University of Texas at Austin Dell Medical SchoolAustinTXUSA
| | | | - Arshed A. Quyyumi
- Emory Clinical Cardiovascular Research Institute, Division of Cardiology, Department of MedicineEmory University School of MedicineAtlantaGAUSA
| | - Brian Telfer
- Lincoln LaboratoryMassachusetts Institute of TechnologyLexingtonMAUSA
| | - Roozbeh Jafari
- Laboratory for Information & Decision Systems (LIDS)Massachusetts Institute of TechnologyCambridgeMAUSA
- Department of Electrical and Computer EngineeringTexas A&M UniversityCollege StationTXUSA
- Lincoln LaboratoryMassachusetts Institute of TechnologyLexingtonMAUSA
- School of Engineering MedicineTexas A&M UniversityHoustonTXUSA
| |
Collapse
|
10
|
Aycock KI, Battisti T, Peterson A, Yao J, Kreuzer S, Capelli C, Pant S, Pathmanathan P, Hoganson DM, Levine SM, Craven BA. Toward trustworthy medical device in silico clinical trials: a hierarchical framework for establishing credibility and strategies for overcoming key challenges. Front Med (Lausanne) 2024; 11:1433372. [PMID: 39188879 PMCID: PMC11346031 DOI: 10.3389/fmed.2024.1433372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 07/10/2024] [Indexed: 08/28/2024] Open
Abstract
Computational models of patients and medical devices can be combined to perform an in silico clinical trial (ISCT) to investigate questions related to device safety and/or effectiveness across the total product life cycle. ISCTs can potentially accelerate product development by more quickly informing device design and testing or they could be used to refine, reduce, or in some cases to completely replace human subjects in a clinical trial. There are numerous potential benefits of ISCTs. An important caveat, however, is that an ISCT is a virtual representation of the real world that has to be shown to be credible before being relied upon to make decisions that have the potential to cause patient harm. There are many challenges to establishing ISCT credibility. ISCTs can integrate many different submodels that potentially use different modeling types (e.g., physics-based, data-driven, rule-based) that necessitate different strategies and approaches for generating credibility evidence. ISCT submodels can include those for the medical device, the patient, the interaction of the device and patient, generating virtual patients, clinical decision making and simulating an intervention (e.g., device implantation), and translating acute physics-based simulation outputs to health-related clinical outcomes (e.g., device safety and/or effectiveness endpoints). Establishing the credibility of each ISCT submodel is challenging, but is nonetheless important because inaccurate output from a single submodel could potentially compromise the credibility of the entire ISCT. The objective of this study is to begin addressing some of these challenges and to identify general strategies for establishing ISCT credibility. Most notably, we propose a hierarchical approach for assessing the credibility of an ISCT that involves systematically gathering credibility evidence for each ISCT submodel in isolation before demonstrating credibility of the full ISCT. Also, following FDA Guidance for assessing computational model credibility, we provide suggestions for ways to clearly describe each of the ISCT submodels and the full ISCT, discuss considerations for performing an ISCT model risk assessment, identify common challenges to demonstrating ISCT credibility, and present strategies for addressing these challenges using our proposed hierarchical approach. Finally, in the Appendix we illustrate the many concepts described here using a hypothetical ISCT example.
Collapse
Affiliation(s)
- Kenneth I. Aycock
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, United States
| | | | | | - Jiang Yao
- Dassault Systèmes, Waltham, MA, United States
| | | | - Claudio Capelli
- Institute of Cardiovascular Science, University College London, London, United Kingdom
| | - Sanjay Pant
- Faculty of Science and Engineering, Swansea University, Swansea, United Kingdom
| | - Pras Pathmanathan
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, United States
| | - David M. Hoganson
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, MA, United States
| | | | - Brent A. Craven
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, United States
| |
Collapse
|
11
|
Huang Y, Dai H, Xu J, Wei R, Sun L, Guo Y, Guo J, Bian J. Evolution of digital twins in precision health applications: a scoping review study. RESEARCH SQUARE 2024:rs.3.rs-4612942. [PMID: 39149471 PMCID: PMC11326392 DOI: 10.21203/rs.3.rs-4612942/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
An increasing amount of research is incorporating the concept of Digital twin (DT) in biomedical and health care applications. This scoping review aims to summarize existing research and identify gaps in the development and use of DTs in the health care domain. The focus of this study lies on summarizing: the different types of DTs, the techniques employed in DT development, the DT applications in health care, and the data resources used for creating DTs. We identified fifty studies, which mainly focused on creating organ- (n=15) and patient-specific twins (n=30). The research predominantly centers on cardiology, endocrinology, orthopedics, and infectious diseases. Only a few studies used real-world datasets for developing their DTs. However, there remain unresolved questions and promising directions that require further exploration. This review provides valuable reference material and insights for researchers on DTs in health care and highlights gaps and unmet needs in this field.
Collapse
Affiliation(s)
- Yu Huang
- Department of Health Outcomes and Biomedical Informatics, University of Florida, Gainesville, FL, USA
| | - Hao Dai
- Department of Health Outcomes and Biomedical Informatics, University of Florida, Gainesville, FL, USA
| | - Jie Xu
- Department of Health Outcomes and Biomedical Informatics, University of Florida, Gainesville, FL, USA
| | - Ruoqi Wei
- Department of Health Outcomes and Biomedical Informatics, University of Florida, Gainesville, FL, USA
| | - Leyang Sun
- Department of Health Outcomes and Biomedical Informatics, University of Florida, Gainesville, FL, USA
| | - Yi Guo
- Department of Health Outcomes and Biomedical Informatics, University of Florida, Gainesville, FL, USA
| | - Jingchuan Guo
- Department of Pharmaceutical Outcomes and Policy, University of Florida, Gainesville, FL, USA
| | - Jiang Bian
- Department of Health Outcomes and Biomedical Informatics, University of Florida, Gainesville, FL, USA
| |
Collapse
|
12
|
Pathmanathan P, Aycock K, Badal A, Bighamian R, Bodner J, Craven BA, Niederer S. Credibility assessment of in silico clinical trials for medical devices. PLoS Comput Biol 2024; 20:e1012289. [PMID: 39116026 PMCID: PMC11309390 DOI: 10.1371/journal.pcbi.1012289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 07/01/2024] [Indexed: 08/10/2024] Open
Abstract
In silico clinical trials (ISCTs) are an emerging method in modeling and simulation where medical interventions are evaluated using computational models of patients. ISCTs have the potential to provide cost-effective, time-efficient, and ethically favorable alternatives for evaluating the safety and effectiveness of medical devices. However, ensuring the credibility of ISCT results is a significant challenge. This paper aims to identify unique considerations for assessing the credibility of ISCTs and proposes an ISCT credibility assessment workflow based on recently published model assessment frameworks. First, we review various ISCTs described in the literature, carefully selected to showcase the range of methodological options available. These studies cover a wide variety of devices, reasons for conducting ISCTs, patient model generation approaches including subject-specific versus 'synthetic' virtual patients, complexity levels of devices and patient models, incorporation of clinician or clinical outcome models, and methods for integrating ISCT results with real-world clinical trials. We next discuss how verification, validation, and uncertainty quantification apply to ISCTs, considering the range of ISCT approaches identified. Based on our analysis, we then present a hierarchical workflow for assessing ISCT credibility, using a general credibility assessment framework recently published by the FDA's Center for Devices and Radiological Health. Overall, this work aims to promote standardization in ISCTs and contribute to the wider adoption and acceptance of ISCTs as a reliable tool for evaluating medical devices.
Collapse
Affiliation(s)
- Pras Pathmanathan
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Kenneth Aycock
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Andreu Badal
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Ramin Bighamian
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Jeff Bodner
- Medtronic, PLC., Minneapolis, Minnesota, United States of America
| | - Brent A. Craven
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Steven Niederer
- National Heart and Lung Institute, Imperial College, London, United Kingdom
- The Alan Turing Institute, London, United Kingdom
| |
Collapse
|
13
|
Louwagie EM, Rajasekharan D, Feder A, Fang S, Nhan-Chang CL, Mourad M, Myers KM. Parametric Solid Models of the At-Term Uterus From Magnetic Resonance Images. J Biomech Eng 2024; 146:071008. [PMID: 38491978 PMCID: PMC11080951 DOI: 10.1115/1.4065109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 03/12/2024] [Accepted: 03/13/2024] [Indexed: 03/18/2024]
Abstract
Birthing mechanics are poorly understood, though many injuries during childbirth are mechanical, like fetal and maternal tissue damage. Several biomechanical simulation models of parturition have been proposed to investigate birth, but many do not include the uterus. Additionally, most solid models rely on segmenting anatomical structures from clinical images to generate patient geometry, which can be time-consuming. This work presents two new parametric solid modeling methods for generating patient-specific, at-term uterine three-dimensional geometry. Building from an established method of modeling the sagittal uterine shape, this work improves the uterine coronal shape, especially where the fetal head joins the lower uterine wall. Solid models of the uterus and cervix were built from five at-term patients' magnetic resonance imaging (MRI) sets. Using anatomy measurements from MRI-segmented models, two parametric models were created-one that employs an averaged coronal uterine shape and one with multiple axial measurements of the coronal uterus. Through finite element analysis, the two new parametric methods were compared to the MRI-segmented high-fidelity method and a previously published elliptical low-fidelity method. A clear improvement in the at-term uterine shape was found using the two new parametric methods, and agreement in principal Lagrange strain directions was observed across all modeling methods. These methods provide an effective and efficient way to generate three-dimensional solid models of patient-specific maternal uterine anatomy, advancing possibilities for future research in computational birthing biomechanics.
Collapse
Affiliation(s)
- Erin M. Louwagie
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
| | - Divya Rajasekharan
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
| | - Arielle Feder
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
- Tel Aviv University
| | - Shuyang Fang
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
| | - Chia-Ling Nhan-Chang
- Department of Obstetrics & Gynecology, Irving Medical Center, Columbia University, New York, NY 10032
| | - Mirella Mourad
- Department of Obstetrics & Gynecology, Columbia University, Irving Medical Center, New York, NY 10032
- Columbia University Irving Medical Center
| | - Kristin M. Myers
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
| |
Collapse
|
14
|
Jaffery OA, Melki L, Slabaugh G, Good WW, Roney CH. A Review of Personalised Cardiac Computational Modelling Using Electroanatomical Mapping Data. Arrhythm Electrophysiol Rev 2024; 13:e08. [PMID: 38807744 PMCID: PMC11131150 DOI: 10.15420/aer.2023.25] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 12/27/2023] [Indexed: 05/30/2024] Open
Abstract
Computational models of cardiac electrophysiology have gradually matured during the past few decades and are now being personalised to provide patient-specific therapy guidance for improving suboptimal treatment outcomes. The predictive features of these personalised electrophysiology models hold the promise of providing optimal treatment planning, which is currently limited in the clinic owing to reliance on a population-based or average patient approach. The generation of a personalised electrophysiology model entails a sequence of steps for which a range of activation mapping, calibration methods and therapy simulation pipelines have been suggested. However, the optimal methods that can potentially constitute a clinically relevant in silico treatment are still being investigated and face limitations, such as uncertainty of electroanatomical data recordings, generation and calibration of models within clinical timelines and requirements to validate or benchmark the recovered tissue parameters. This paper is aimed at reporting techniques on the personalisation of cardiac computational models, with a focus on calibrating cardiac tissue conductivity based on electroanatomical mapping data.
Collapse
Affiliation(s)
- Ovais A Jaffery
- School of Engineering and Materials Science, Queen Mary University of London London, UK
| | - Lea Melki
- R&D Algorithms, Acutus Medical Carlsbad, CA, US
| | - Gregory Slabaugh
- Digital Environment Research Institute, Queen Mary University of London London, UK
| | | | - Caroline H Roney
- School of Engineering and Materials Science, Queen Mary University of London London, UK
| |
Collapse
|
15
|
Louwagie EM, Russell SR, Hairston JC, Nottman C, Nhan-Chang CL, Fuchs K, Gyamfi-Bannerman C, Booker W, Andrikopoulou M, Friedman A, Zork N, Wapner R, Vink J, Mourad M, Feltovich HM, House MD, Myers KM. Uterus and cervix anatomical changes and cervix stiffness evolution throughout pregnancy. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.05.01.592023. [PMID: 38746471 PMCID: PMC11092586 DOI: 10.1101/2024.05.01.592023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
The coordinated biomechanical performance, such as uterine stretch and cervical barrier function, within maternal reproductive tissues facilitates healthy human pregnancy and birth. Quantifying normal biomechanical function and detecting potentially detrimental biomechanical dysfunction (e.g., cervical insufficiency, uterine overdistention, premature rupture of membranes) is difficult, largely due to minimal data on the shape and size of maternal anatomy and material properties of tissue across gestation. This study quantitates key structural features of human pregnancy to fill this knowledge gap and facilitate three-dimensional modeling for biomechanical pregnancy simulations to deeply explore pregnancy and childbirth. These measurements include the longitudinal assessment of uterine and cervical dimensions, fetal weight, and cervical stiffness in 47 low-risk pregnancies at four time points during gestation (late first, middle second, late second, and middle third trimesters). The uterine and cervical size were measured via 2-dimensional ultrasound, and cervical stiffness was measured via cervical aspiration. Trends in uterine and cervical measurements were assessed as time-course slopes across pregnancy and between gestational time points, accounting for specific participants. Patient-specific computational solid models of the uterus and cervix, generated from the ultrasonic measurements, were used to estimate deformed uterocervical volume. Results show that for this low-risk cohort, the uterus grows fastest in the inferior-superior direction from the late first to middle second trimester and fastest in the anterior-posterior and left-right direction between the middle and late second trimester. Contemporaneously, the cervix softens and shortens. It softens fastest from the late first to the middle second trimester and shortens fastest between the late second and middle third trimester. Alongside the fetal weight estimated from ultrasonic measurements, this work presents holistic maternal and fetal patient-specific biomechanical measurements across gestation.
Collapse
|
16
|
Gray RA, Franz MR. Amiodarone prevents wave front-tail interactions in patients with heart failure: an in silico study. Am J Physiol Heart Circ Physiol 2023; 325:H952-H964. [PMID: 37656133 PMCID: PMC10907032 DOI: 10.1152/ajpheart.00227.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 08/25/2023] [Accepted: 08/25/2023] [Indexed: 09/02/2023]
Abstract
Amiodarone (AM) is an antiarrhythmic drug whose chronic use has proved effective in preventing ventricular arrhythmias in a variety of patient populations, including those with heart failure (HF). AM has both class III [i.e., it prolongs the action potential duration (APD) via blocking potassium channels) and class I (i.e., it affects the rapid sodium channel) properties; however, the specific mechanism(s) by which it prevents reentry formation in patients with HF remains unknown. We tested the hypothesis that AM prevents reentry induction in HF during programmed electrical stimulation (PES) via its ability to induce postrepolarization refractoriness (PRR) via its class I effects on sodium channels. Here we extend our previous human action potential model to represent the effects of both HF and AM separately by calibrating to human tissue and clinical PES data, respectively. We then combine these models (HF + AM) to test our hypothesis. Results from simulations in cells and cables suggest that AM acts to increase PRR and decrease the elevation of takeoff potential. The ability of AM to prevent reentry was studied in silico in two-dimensional sheets in which a variety of APD gradients (ΔAPD) were imposed. Reentrant activity was induced in all HF simulations but was prevented in 23 of 24 HF + AM models. Eliminating the AM-induced slowing of the recovery of inactivation of the sodium channel restored the ability to induce reentry. In conclusion, in silico testing suggests that chronic AM treatment prevents reentry induction in patients with HF during PES via its class I effect to induce PRR.NEW & NOTEWORTHY This work presents a new model of the action potential of the human, which reproduces the complex dynamics during premature stimulation in heart failure patients with and without amiodarone. A specific mechanism of the ability of amiodarone to prevent reentrant arrhythmias is presented.
Collapse
Affiliation(s)
- Richard A Gray
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland, United States
| | - Michael R Franz
- Cardiology Division, Veteran Affairs Medical Center, Washington, District of Columbia, United States
- Department of Pharmacology, Georgetown University Medical Center, Washington, District of Columbia, United States
| |
Collapse
|
17
|
Rodero C, Baptiste TMG, Barrows RK, Keramati H, Sillett CP, Strocchi M, Lamata P, Niederer SA. A systematic review of cardiac in-silico clinical trials. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2023; 5:032004. [PMID: 37360227 PMCID: PMC10286106 DOI: 10.1088/2516-1091/acdc71] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 05/26/2023] [Accepted: 06/07/2023] [Indexed: 06/28/2023]
Abstract
Computational models of the heart are now being used to assess the effectiveness and feasibility of interventions through in-silico clinical trials (ISCTs). As the adoption and acceptance of ISCTs increases, best practices for reporting the methodology and analysing the results will emerge. Focusing in the area of cardiology, we aim to evaluate the types of ISCTs, their analysis methods and their reporting standards. To this end, we conducted a systematic review of cardiac ISCTs over the period of 1 January 2012-1 January 2022, following the preferred reporting items for systematic reviews and meta-analysis (PRISMA). We considered cardiac ISCTs of human patient cohorts, and excluded studies of single individuals and those in which models were used to guide a procedure without comparing against a control group. We identified 36 publications that described cardiac ISCTs, with most of the studies coming from the US and the UK. In 75% of the studies, a validation step was performed, although the specific type of validation varied between the studies. ANSYS FLUENT was the most commonly used software in 19% of ISCTs. The specific software used was not reported in 14% of the studies. Unlike clinical trials, we found a lack of consistent reporting of patient demographics, with 28% of the studies not reporting them. Uncertainty quantification was limited, with sensitivity analysis performed in only 19% of the studies. In 97% of the ISCTs, no link was provided to provide easy access to the data or models used in the study. There was no consistent naming of study types with a wide range of studies that could potentially be considered ISCTs. There is a clear need for community agreement on minimal reporting standards on patient demographics, accepted standards for ISCT cohort quality control, uncertainty quantification, and increased model and data sharing.
Collapse
Affiliation(s)
- Cristobal Rodero
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Cardiac Modelling and Imaging Biomarkers (CMIB), Department of Biomedical Engineering and Imaging Sciences Department, King’s College London, London, United Kingdom
| | - Tiffany M G Baptiste
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Rosie K Barrows
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Hamed Keramati
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Cardiac Modelling and Imaging Biomarkers (CMIB), Department of Biomedical Engineering and Imaging Sciences Department, King’s College London, London, United Kingdom
| | - Charles P Sillett
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Marina Strocchi
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Pablo Lamata
- Cardiac Modelling and Imaging Biomarkers (CMIB), Department of Biomedical Engineering and Imaging Sciences Department, King’s College London, London, United Kingdom
| | - Steven A Niederer
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Turing Research and Innovation Cluster in Digital Twins (TRIC: DT), The Alan Turing Institute, London, United Kingdom
| |
Collapse
|
18
|
Strocchi M, Longobardi S, Augustin CM, Gsell MAF, Petras A, Rinaldi CA, Vigmond EJ, Plank G, Oates CJ, Wilkinson RD, Niederer SA. Cell to whole organ global sensitivity analysis on a four-chamber heart electromechanics model using Gaussian processes emulators. PLoS Comput Biol 2023; 19:e1011257. [PMID: 37363928 DOI: 10.1371/journal.pcbi.1011257] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 06/09/2023] [Indexed: 06/28/2023] Open
Abstract
Cardiac pump function arises from a series of highly orchestrated events across multiple scales. Computational electromechanics can encode these events in physics-constrained models. However, the large number of parameters in these models has made the systematic study of the link between cellular, tissue, and organ scale parameters to whole heart physiology challenging. A patient-specific anatomical heart model, or digital twin, was created. Cellular ionic dynamics and contraction were simulated with the Courtemanche-Land and the ToR-ORd-Land models for the atria and the ventricles, respectively. Whole heart contraction was coupled with the circulatory system, simulated with CircAdapt, while accounting for the effect of the pericardium on cardiac motion. The four-chamber electromechanics framework resulted in 117 parameters of interest. The model was broken into five hierarchical sub-models: tissue electrophysiology, ToR-ORd-Land model, Courtemanche-Land model, passive mechanics and CircAdapt. For each sub-model, we trained Gaussian processes emulators (GPEs) that were then used to perform a global sensitivity analysis (GSA) to retain parameters explaining 90% of the total sensitivity for subsequent analysis. We identified 45 out of 117 parameters that were important for whole heart function. We performed a GSA over these 45 parameters and identified the systemic and pulmonary peripheral resistance as being critical parameters for a wide range of volumetric and hemodynamic cardiac indexes across all four chambers. We have shown that GPEs provide a robust method for mapping between cellular properties and clinical measurements. This could be applied to identify parameters that can be calibrated in patient-specific models or digital twins, and to link cellular function to clinical indexes.
Collapse
Affiliation(s)
- Marina Strocchi
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Stefano Longobardi
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | | | | | - Argyrios Petras
- Johann Radon Institute for Computational and Applied Mathematics (RICAM), Linz, Austria
| | - Christopher A Rinaldi
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Edward J Vigmond
- University of Bordeaux, CNRS, Bordeaux, Talence, France
- IHU Liryc, Bordeaux, Talence, France
| | - Gernot Plank
- Medical University of Graz, Graz, Austria
- BioTechMed-Graz, Graz, Austria
| | - Chris J Oates
- Newcastle University, Newcastle upon Tyne, United Kingdom
| | | | - Steven A Niederer
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Alan Turing Institute, London, United Kingdom
| |
Collapse
|