1
|
Gallez B. Contribution of Harold M. Swartz to In Vivo EPR and EPR Dosimetry. RADIATION PROTECTION DOSIMETRY 2016; 172:16-37. [PMID: 27421469 DOI: 10.1093/rpd/ncw157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In 2015, we are celebrating half a century of research in the application of Electron Paramagnetic Resonance (EPR) as a biodosimetry tool to evaluate the dose received by irradiated people. During the EPR Biodose 2015 meeting, a special session was organized to acknowledge the pioneering contribution of Harold M. (Hal) Swartz in the field. The article summarizes his main contribution in physiology and medicine. Four emerging themes have been pursued continuously along his career since its beginning: (1) radiation biology; (2) oxygen and oxidation; (3) measuring physiology in vivo; and (4) application of these measurements in clinical medicine. The common feature among all these different subjects has been the use of magnetic resonance techniques, especially EPR. In this article, you will find an impressionist portrait of Hal Swartz with the description of the 'making of' this pioneer, a time-line perspective on his career with the creation of three National Institutes of Health-funded EPR centers, a topic-oriented perspective on his career with a description of his major contributions to Science, his role as a mentor and his influence on his academic children, his active role as founder of scientific societies and organizer of scientific meetings, and the well-deserved international recognition received so far.
Collapse
Affiliation(s)
- Bernard Gallez
- Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Avenue Mounier 73.08, B-1200, Brussels, Belgium
| |
Collapse
|
2
|
Desmet CM, Levêque P, Gallez B. Factors Affecting the Quality of Tooth Enamel for In Vivo EPR-Based Retrospective Biodosimetry. RADIATION PROTECTION DOSIMETRY 2016; 172:96-102. [PMID: 27473693 PMCID: PMC5225974 DOI: 10.1093/rpd/ncw212] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In vivo electron paramagnetic resonance biodosimetry on tooth enamel is likely to be an important technology for triage of overexposed individuals after a major radiological incident. The accuracy and robustness of the technique relies on various properties of the enamel such as the geometry of the tooth, the presence of restorations, whitening treatments or exposition to sunlight. Those factors are reviewed, and their influence on dosimetry specifically for triage purposes is discussed.
Collapse
Affiliation(s)
- Céline M Desmet
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| | - Philippe Levêque
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| | - Bernard Gallez
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| |
Collapse
|
3
|
Wang L, Wang X, Zhang W, Zhang H, Ruan S, Jiao L. Determining Dosimetric Properties and Lowest Detectable Dose of Fingernail Clippings from their Electron Paramagnetic Resonance Signal. HEALTH PHYSICS 2015; 109:10-14. [PMID: 26011494 DOI: 10.1097/hp.0000000000000277] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The purpose of this study was to investigate the dosimetric properties and the lowest detectable dose of fingernails from their electron paramagnetic resonance signal. Fingernail clippings from 50 healthy individuals were collected, rinsed in water, and irradiated with (137)Cs gamma rays. Next, their electron paramagnetic resonance spectra were measured before and after exposure. The radiation-induced signal from the irradiated fingernails was relatively stable even after 68 d. Further, the intensity of the radiation-induced signal increased with progressive increases in the dose until saturation, while the background signal from the irradiated fingernails increased only gradually with time. The lowest detectable dose of the irradiated fingernails was 2 Gy. On the basis of these results, it can be concluded that the effect of the intrinsic signal must be taken into account during dose reconstruction. This electron paramagnetic resonance assessment method should be useful for the rapid screening of irradiated populations after nuclear accidents.
Collapse
Affiliation(s)
- Liang Wang
- *Institute of Radiation Medicine, Chinese Academy of Medical Sciences/Peking Union Medical College, 238 Baidi Road, Nankai District, Tianjin 300192, P.R. China
| | | | | | | | | | | |
Collapse
|
4
|
Desmet CM, Djurkin A, Dos Santos-Goncalvez AM, Dong R, Kmiec MM, Kobayashi K, Rychert K, Beun S, Leprince JG, Leloup G, Levêque P, Gallez B. Tooth Retrospective Dosimetry Using Electron Paramagnetic Resonance: Influence of Irradiated Dental Composites. PLoS One 2015; 10:e0131913. [PMID: 26125565 PMCID: PMC4488324 DOI: 10.1371/journal.pone.0131913] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Accepted: 06/08/2015] [Indexed: 11/25/2022] Open
Abstract
In the aftermath of a major radiological accident, the medical management of overexposed individuals will rely on the determination of the dose of ionizing radiations absorbed by the victims. Because people in the general population do not possess conventional dosimeters, after the fact dose reconstruction methods are needed. Free radicals are induced by radiations in the tooth enamel of victims, in direct proportion to dose, and can be quantified using Electron Paramagnetic Resonance (EPR) spectrometry, a technique that was demonstrated to be very appropriate for mass triage. The presence of dimethacrylate based restorations on teeth can interfere with the dosimetric signal from the enamel, as free radicals could also be induced in the various composites used. The aim of the present study was to screen irradiated composites for a possible radiation-induced EPR signal, to characterize it, and evaluate a possible interference with the dosimetric signal of the enamel. We investigated the most common commercial composites, and experimental compositions, for a possible class effect. The effect of the dose was studied between 10 Gy and 100 Gy using high sensitivity X-band spectrometer. The influence of this radiation-induced signal from the composite on the dosimetric signal of the enamel was also investigated using a clinical L-Band EPR spectrometer, specifically developed in the EPR center at Dartmouth College. In X-band, a radiation-induced signal was observed for high doses (25-100 Gy); it was rapidly decaying, and not detected after only 24h post irradiation. At 10 Gy, the signal was in most cases not measurable in the commercial composites tested, with the exception of 3 composites showing a significant intensity. In L-band study, only one irradiated commercial composite influenced significantly the dosimetric signal of the tooth, with an overestimation about 30%. In conclusion, the presence of the radiation-induced signal from dental composites should not significantly influence the dosimetry for early dose assessment.
Collapse
Affiliation(s)
- Céline M. Desmet
- Biomedical Magnetic Resonance Research group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | - Andrej Djurkin
- School of Dentistry and Stomatology, Université catholique de Louvain, Brussels, Belgium
| | - Ana Maria Dos Santos-Goncalvez
- Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | - Ruhong Dong
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, United States of America
| | - Maciej M. Kmiec
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, United States of America
| | - Kyo Kobayashi
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, United States of America
| | - Kevin Rychert
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, United States of America
| | - Sébastien Beun
- School of Dentistry and Stomatology, Université catholique de Louvain, Brussels, Belgium
| | - Julian G. Leprince
- Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
| | - Gaëtane Leloup
- Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
| | - Philippe Levêque
- Biomedical Magnetic Resonance Research group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | - Bernard Gallez
- Biomedical Magnetic Resonance Research group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
- * E-mail:
| |
Collapse
|
5
|
Meaney PM, Williams BB, Geimer SD, Flood AB, Swartz HM. A Coaxial Dielectric Probe Technique for Distinguishing Tooth Enamel from Dental Resin. ACTA ACUST UNITED AC 2015; 3:8-17. [PMID: 27182531 DOI: 10.14355/aber.2015.03.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
For purposes of biodosimetry in the event of a large scale radiation disaster, one major and very promising point-of contact device is assessing dose using tooth enamel. This technique utilizes the capabilities of electron paramagnetic resonance to measure free radicals and other unpaired electron species, and the fact that the deposition of energy from ionizing radiation produces free radicals in most materials. An important stipulation for this strategy is that the measurements, need to be performed on a central incisor that is basically intact, i.e. which has an area of enamel surface that is as large as the probing tip of the resonator that is without decay or restorative care that replaces the enamel. Therefore, an important consideration is how to quickly assess whether the tooth has sufficient enamel to be measured for dose and whether there is resin present on the tooth being measured and to be able to characterize the amount of surface that is impacted. While there is a relatively small commercially available dielectric probe which could be used in this context, it has several disadvantages for the intended use. Therefore, a smaller, 1.19mm diameter 50 ohm, open-ended, coaxial dielectric probe has been developed as an alternative. The performance of the custom probe was validated against measurement results of known standards. Measurements were taken of multiple teeth enamel and dental resin samples using both probes. While the probe contact with the teeth samples was imperfect and added to measurement variability, the inherent dielectric contrast between the enamel and resin was sufficient that the probe measurements could be used as a robust means of distinguishing the two material types. The smaller diameter probe produced markedly more definitive results in terms of distinguishing the two materials.
Collapse
Affiliation(s)
- Paul M Meaney
- Thayer School of Engineering, Dartmouth College, Hanover, NH USA
| | | | | | - Ann B Flood
- Geisel School of Medicine, Dartmouth College, Hanover, NH USA
| | - Harold M Swartz
- Geisel School of Medicine, Dartmouth College, Hanover, NH USA
| |
Collapse
|