1
|
Bonneau N, Baudouin C, Réaux-Le Goazigo A, Brignole-Baudouin F. An overview of current alternative models in the context of ocular surface toxicity. J Appl Toxicol 2021; 42:718-737. [PMID: 34648674 DOI: 10.1002/jat.4246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 08/31/2021] [Accepted: 09/15/2021] [Indexed: 11/06/2022]
Abstract
The 21st century has seen a steadily increasing social awareness of animal suffering, with increased attention to ethical considerations. Developing new integrated approaches to testing and assessment (IATA) strategies is an Organisation for Economic Co-operation and Development (OECD) goal to reduce animal testing. Currently, there is a lack of alternative models to test for ocular surface toxicity (aside from irritation) in lieu of the Draize eye irritation test (OECD guideline No. 405) performed in rabbits. Five alternative in vitro or ex vivo methods have been validated to replace this reference test, but only in combination. However, pathologies like Toxicity-Induced Dry Eye (TIDE), cataract, glaucoma, and neuropathic pain can occur after exposure to a pharmaceutical product or chemical and therefore need to be anticipated. To do so, new models of lacrimal glands, lens, and neurons innervating epithelia are required. These models must take into account real-life exposure (dose, time, and tear film clearance). The scientific community is working hard to develop new, robust, alternative, in silico, and in vitro models, while attempting to balance ethics and availability of biological materials. This review provides a broad overview of the validated methods for analyzing ocular irritation and those still used by some industries, as well as promising models that need to be optimized according to the OECD. Finally, we give an overview of recently developed innovative models, which could become new tools in the evaluation of ocular surface toxicity within the scope of IATAs.
Collapse
Affiliation(s)
- Noémie Bonneau
- Sorbonne Université, INSERM, CNRS, IHU FOReSight, Institut de la Vision, Paris, France.,Horus Pharma, Saint-Laurent-du-Var, France
| | - Christophe Baudouin
- Sorbonne Université, INSERM, CNRS, IHU FOReSight, Institut de la Vision, Paris, France.,Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts, INSERM-DGOS CIC 1423, IHU FOReSight, Paris, France.,Université Versailles-Saint-Quentin-en-Yvelines, Hôpital Ambroise Paré, APHP, Boulogne-Billancourt, France
| | | | - Françoise Brignole-Baudouin
- Sorbonne Université, INSERM, CNRS, IHU FOReSight, Institut de la Vision, Paris, France.,Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts, INSERM-DGOS CIC 1423, IHU FOReSight, Paris, France.,Laboratoire d'Ophtalmobiologie, Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts, IHU FOReSight, Paris, France.,Université de Paris, Faculté de Pharmacie de Paris, Département de Toxicologie, Paris, France
| |
Collapse
|
2
|
Clippinger AJ, Raabe HA, Allen DG, Choksi NY, van der Zalm AJ, Kleinstreuer NC, Barroso J, Lowit AB. Human-relevant approaches to assess eye corrosion/irritation potential of agrochemical formulations. Cutan Ocul Toxicol 2021; 40:145-167. [PMID: 33830843 DOI: 10.1080/15569527.2021.1910291] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
There are multiple in vitro and ex vivo eye irritation and corrosion test methods that are available as internationally harmonized test guidelines for regulatory use. Despite their demonstrated usefulness to a broad range of substances through inter-laboratory validation studies, they have not been widely adopted for testing agrochemical formulations due to a lack of concordance with parallel results from the traditional regulatory test method for this endpoint, the rabbit eye test. The inherent variability of the rabbit test, differences in the anatomy of the rabbit and human eyes, and differences in modelling exposures in rabbit eyes relative to human eyes contribute to this lack of concordance. Ultimately, the regulatory purpose for these tests is protection of human health, and, thus, there is a need for a testing approach based on human biology. This paper reviews the available in vivo, in vitro and ex vivo test methods with respect to their relevance to human ocular anatomy, anticipated exposure scenarios, and the mechanisms of eye irritation/corrosion in humans. Each of the in vitro and ex vivo methods described is generally appropriate for identifying non-irritants. To discriminate among eye irritants, the human three-dimensional epithelial and full thickness corneal models provide the most detailed information about the severity of irritation. Consideration of the mechanisms of eye irritation, and the strengths and limitations of the in vivo, in vitro and ex vivo test methods, show that the in vitro/ex vivo methods are as or more reflective of human biology and less variable than the currently used rabbit approach. Suggestions are made for further optimizing the most promising methods to distinguish between severe (corrosive), moderate, mild and non-irritants and provide information about the reversibility of effects. Also considered is the utility of including additional information (e.g. physical chemical properties), consistent with the Organization for Economic Cooperation and Development's guidance document on an integrated approach to testing and assessment of potential eye irritation. Combining structural and functional information about a test substance with test results from human-relevant methods will ensure the best protection of humans following accidental eye exposure to agrochemicals.
Collapse
Affiliation(s)
| | - Hans A Raabe
- Institute for In Vitro Sciences, Inc., Gaithersburg, MD, USA
| | - David G Allen
- Integrated Laboratory Systems, LLC, Research Triangle Park, NC, USA
| | - Neepa Y Choksi
- Integrated Laboratory Systems, LLC, Research Triangle Park, NC, USA
| | | | - Nicole C Kleinstreuer
- National Toxicology Program, National Institute of Environmental Health Sciences, Research Triangle Park, NC, USA
| | - João Barroso
- European Commission, Joint Research Centre (JRC), Ispra, VA, Italy
| | - Anna B Lowit
- US Environmental Protection Agency Office of Pesticide Programs, Washington, DC, USA
| |
Collapse
|
3
|
Material Characterisation and Stratification of Conjunctival Epithelial Cells on Electrospun Poly(ε-Caprolactone) Fibres Loaded with Decellularised Tissue Matrices. Pharmaceutics 2021; 13:pharmaceutics13030318. [PMID: 33671006 PMCID: PMC7997349 DOI: 10.3390/pharmaceutics13030318] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/17/2021] [Accepted: 02/24/2021] [Indexed: 12/16/2022] Open
Abstract
The conjunctiva, an under-researched yet incredibly important tissue, plays key roles in providing protection to the eye and maintaining homeostasis of its ocular surface. Multiple diseases can impair conjunctival function leading to severe consequences that require surgical intervention. Small conjunctival defects can be repaired relatively easily, but larger defects rely on tissue grafts which generally do not provide adequate healing. A tissue engineering approach involving a biomaterial substrate capable of supporting a stratified epithelium with embedded, mucin-secreting goblet cells offers a potential solution. As a first step, this study aimed to induce stratification of human conjunctival epithelial cells cultured on electrospun scaffolds composed from poly(ε-caprolactone) (PCL) and decellularised tissue matrix (small intestinal submucosa (SIS) or urinary bladder matrix (UBM)) and held at the air/liquid interface. Stratification, up to 5 cell layers, occurred more frequently on scaffolds containing PCL + UBM. Incorporation of these decellularised tissue matrices also impacted material properties, with significant changes occurring to their fibre diameter, tensile properties, and chemical composition throughout the scaffold structure compared to PCL alone. These matrix containing scaffolds warrant further long-term investigation as a potential advanced therapy medicinal product for conjunctiva repair and regeneration.
Collapse
|
4
|
García-Posadas L, Diebold Y. Three-Dimensional Human Cell Culture Models to Study the Pathophysiology of the Anterior Eye. Pharmaceutics 2020; 12:E1215. [PMID: 33333869 PMCID: PMC7765302 DOI: 10.3390/pharmaceutics12121215] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 12/11/2020] [Accepted: 12/13/2020] [Indexed: 02/07/2023] Open
Abstract
In recent decades, the establishment of complex three-dimensional (3D) models of tissues has allowed researchers to perform high-quality studies and to not only advance knowledge of the physiology of these tissues but also mimic pathological conditions to test novel therapeutic strategies. The main advantage of 3D models is that they recapitulate the spatial architecture of tissues and thereby provide more physiologically relevant information. The eye is an extremely complex organ that comprises a large variety of highly heterogeneous tissues that are divided into two asymmetrical portions: the anterior and posterior segments. The anterior segment consists of the cornea, conjunctiva, iris, ciliary body, sclera, aqueous humor, and the lens. Different diseases in these tissues can have devastating effects. To study these pathologies and develop new treatments, the use of cell culture models is instrumental, and the better the model, the more relevant the results. Thus, the development of sophisticated 3D models of ocular tissues is a significant challenge with enormous potential. In this review, we present a comprehensive overview of the latest advances in the development of 3D in vitro models of the anterior segment of the eye, with a special focus on those that use human primary cells.
Collapse
Affiliation(s)
- Laura García-Posadas
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, 47011 Valladolid, Spain;
| | - Yolanda Diebold
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, 47011 Valladolid, Spain;
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, 28029 Madrid, Spain
| |
Collapse
|
5
|
Development of In Vitro Corneal Models: Opportunity for Pharmacological Testing. Methods Protoc 2020; 3:mps3040074. [PMID: 33147693 PMCID: PMC7711486 DOI: 10.3390/mps3040074] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 10/30/2020] [Indexed: 12/12/2022] Open
Abstract
The human eye is a specialized organ with a complex anatomy and physiology, because it is characterized by different cell types with specific physiological functions. Given the complexity of the eye, ocular tissues are finely organized and orchestrated. In the last few years, many in vitro models have been developed in order to meet the 3Rs principle (Replacement, Reduction and Refinement) for eye toxicity testing. This procedure is highly necessary to ensure that the risks associated with ophthalmic products meet appropriate safety criteria. In vitro preclinical testing is now a well-established practice of significant importance for evaluating the efficacy and safety of cosmetic, pharmaceutical, and nutraceutical products. Along with in vitro testing, also computational procedures, herein described, for evaluating the pharmacological profile of potential ocular drug candidates including their toxicity, are in rapid expansion. In this review, the ocular cell types and functionality are described, providing an overview about the scientific challenge for the development of three-dimensional (3D) in vitro models.
Collapse
|
6
|
Lotz C, Kiesewetter L, Schmid FF, Hansmann J, Walles H, Groeber-Becker F. Replacing the Draize eye test: Impedance spectroscopy as a 3R method to discriminate between all GHS categories for eye irritation. Sci Rep 2018; 8:15049. [PMID: 30301970 PMCID: PMC6177390 DOI: 10.1038/s41598-018-33118-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 09/21/2018] [Indexed: 11/09/2022] Open
Abstract
Highly invasive animal based test procedures for risk assessment such as the Draize eye test are under increasing criticism due to poor transferability for the human organism and animal-welfare concerns. However, besides all efforts, the Draize eye test is still not completely replaced by alternative animal-free methods. To develop an in vitro test to identify all categories of eye irritation, we combined organotypic cornea models based on primary human cells with an electrical readout system that measures the impedance of the test models. First, we showed that employing a primary human cornea epithelial cell based model is advantageous in native marker expression to the primary human epidermal keratinocytes derived models. Secondly, by employing a non-destructive measuring system based on impedance spectroscopy, we could increase the sensitivity of the test system. Thereby, all globally harmonized systems categories of eye irritation could be identified by repeated measurements over a period of 7 days. Based on a novel prediction model we achieved an accuracy of 78% with a reproducibility of 88.9% to determine all three categories of eye irritation in one single test. This could pave the way according to the 3R principle to replace the Draize eye test.
Collapse
Affiliation(s)
- C Lotz
- Department Tissue Engineering & Regenerative Medicine (TERM), University Hospital Würzburg, Würzburg, 97070, Germany.
| | - L Kiesewetter
- Department Tissue Engineering & Regenerative Medicine (TERM), University Hospital Würzburg, Würzburg, 97070, Germany
| | - F F Schmid
- Translational Center for Regenerative Therapies, Fraunhofer Institute for Silicate Research, Würzburg, 97070, Germany
| | - J Hansmann
- Department Tissue Engineering & Regenerative Medicine (TERM), University Hospital Würzburg, Würzburg, 97070, Germany.,Translational Center for Regenerative Therapies, Fraunhofer Institute for Silicate Research, Würzburg, 97070, Germany
| | - H Walles
- Department Tissue Engineering & Regenerative Medicine (TERM), University Hospital Würzburg, Würzburg, 97070, Germany.,Translational Center for Regenerative Therapies, Fraunhofer Institute for Silicate Research, Würzburg, 97070, Germany
| | - F Groeber-Becker
- Translational Center for Regenerative Therapies, Fraunhofer Institute for Silicate Research, Würzburg, 97070, Germany
| |
Collapse
|
7
|
da Silva ACG, Chialchia AR, de Ávila RI, Valadares MC. Mechanistic-based non-animal assessment of eye toxicity: Inflammatory profile of human keratinocytes cells after exposure to eye damage/irritant agents. Chem Biol Interact 2018; 292:1-8. [DOI: 10.1016/j.cbi.2018.06.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 06/11/2018] [Accepted: 06/24/2018] [Indexed: 11/29/2022]
|
8
|
Assessment of the eye irritation potential of chemicals: A comparison study between two test methods based on human 3D hemi-cornea models. Toxicol In Vitro 2015; 30:561-8. [PMID: 26362509 DOI: 10.1016/j.tiv.2015.09.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 09/02/2015] [Accepted: 09/06/2015] [Indexed: 11/21/2022]
Abstract
We have recently developed two hemi-cornea models (Bartok et al., Toxicol in Vitro 29, 72, 2015; Zorn-Kruppa et al. PLoS One 9, e114181, 2014), which allow the correct prediction of eye irritation potential of chemicals according to the United Nations globally harmonized system of classification and labeling of chemicals (UN GHS). Both models comprise a multilayered epithelium and a stroma with embedded keratocytes in a collagenous matrix. These two models were compared, using a set of fourteen test chemicals. Their effects after 10 and 60 minutes (min) exposure were assessed from the quantification of cell viability using the MTT reduction assay. The first approach separately quantifies the damage inflicted to the epithelium and the stroma. The second approach quantifies the depth of injury by recording cell death as a function of depth. The classification obtained by the two models was compared to the Draize rabbit eye test and an ex vivo model using rabbit cornea (Jester et al. Toxicol in Vitro. 24, 597-604, 2010). With a 60 min exposure, both of our models are able to clearly differentiate UN GHS Category 1 and UN GHS Category 2 test chemicals.
Collapse
|
9
|
A custom tailored model to investigate skin penetration in porcine skin and its comparison with human skin. Eur J Pharm Biopharm 2015; 95:99-109. [DOI: 10.1016/j.ejpb.2015.03.030] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Revised: 03/05/2015] [Accepted: 03/09/2015] [Indexed: 11/22/2022]
|