1
|
Bizet B, Nordez A, Tallio T, Lacourpaille L, Cattagni T, Colard J, Betus Y, Dorel S, Sarcher A, Seynnes O, Andrade RJ. Eight weeks of eccentric training at long-muscle length increases fascicle length independently of adaptations in passive mechanical properties. J Appl Physiol (1985) 2025; 138:939-949. [PMID: 40048648 DOI: 10.1152/japplphysiol.00859.2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2024] [Revised: 12/01/2024] [Accepted: 03/02/2025] [Indexed: 03/29/2025] Open
Abstract
Eccentric exercise training is believed to induce an increase in muscle fascicle length. However, the mechanisms underlying this adaptation are not fully understood. This study aimed to determine if an increase in gastrocnemius medialis fascicle length following an 8-wk eccentric training is linked to changes in muscle tissue and joint mechanical properties. Thirty-three physically active young adults were assigned to one of the two training protocols targeting the plantar flexors: eccentric exercise at 1) long-muscle length or 2) short-muscle length. Fascicle length and muscle shear modulus of the gastrocnemius medialis were assessed using ultrasound imaging during passive ankle rotations, alongside measurements of passive ankle torque. A total of 27 participants successfully completed the training program and data processing stage (long-muscle length, n = 15; short-muscle length, n = 12). Maximal voluntary isometric torque increased significantly following the training programs (9.5%), with no differences between training groups. An increase in fascicle length (mean 8.5%) was observed in the long-muscle length group, from 39.5 ± 0.7° to 36.8 ± 0.8° in plantar flexion, but not in the short-muscle length group. Notably, this macrostructural adaptation was detected only at muscle lengths shorter than the slack length (i.e., absence of any muscle passive tension). The eccentric training did not alter the muscle shear modulus or slack length. Collectively, these findings suggest that fascicle length adaptations in response to eccentric training were unrelated to changes in passive muscle-tendon mechanical properties. Consequently, the increase in fascicle length may be attributed to an increase in sarcomere length and/or an addition of sarcomeres in series.NEW & NOTEWORTHY We demonstrate that an 8-wk eccentric training program significantly increases gastrocnemius medialis fascicle length in humans, independent of any adaptions in passive muscle-tendon mechanical properties. Fascicle length adaptions were specific to the group that trained at long-muscle lengths, highlighting the importance of the muscle-tendon length range during eccentric exercise programs. This factor may be crucial for fine-tuning structural adaptations at the fascicle level, likely through the addition of sarcomeres in series.
Collapse
Affiliation(s)
- Baptiste Bizet
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
- Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy
| | - Antoine Nordez
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
- Institut Universitaire de France, Paris, France
| | - Tristan Tallio
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
| | - Lilian Lacourpaille
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
| | - Thomas Cattagni
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
| | - Julian Colard
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
| | - Yohan Betus
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
| | - Sylvain Dorel
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
| | - Aurélie Sarcher
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
| | - Olivier Seynnes
- Department for Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Ricardo J Andrade
- Movement - Interactions - Performance, MIP, UR 4334, Nantes Université, Nantes, France
| |
Collapse
|
2
|
Jiang W, Chen C, Xu Y. Muscle structure predictors of vertical jump performance in elite male volleyball players: a cross-sectional study based on ultrasonography. Front Physiol 2024; 15:1427748. [PMID: 39139479 PMCID: PMC11319176 DOI: 10.3389/fphys.2024.1427748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2024] [Accepted: 06/25/2024] [Indexed: 08/15/2024] Open
Abstract
Objective The objective of this investigation is to examine the contribution of key muscle groups in the lower limbs to vertical jumping performance in elite male volleyball players. Specifically, the study focuses on the rectus femoris (RF), vastus lateralis (VL), and lateral gastrocnemius (LG), as well as exploring differences between attack jump and other vertical jump types. Methods To achieve this, we employed B-mode ultrasound to evaluate the anatomical cross-sectional area (ACSA), muscle thickness (MT), pennation angle (PA), and fascicle length (FL) of the RF, VL, and LG in the participants. Fifteen elite male volleyball players were recruited as participants for this study. Jump heights were measured for four types of vertical jumps: attack jump (AJ), countermovement jump (CMJ), squat jump (SJ), and drop jump (DJ). We conducted regression analyses to assess whether the previously mentioned muscle structures could predict jump performance. Results Our findings reveal that the muscle structure of the RF does not exhibit any significant correlation with the height of any jump. However, VL-ACSA displays a significant and the most potent predictive effect on jump height for all four jump types (AJ: R 2 = 0.32, p = 0.001; CMJ: R 2 = 0.37, p = 0.005; SJ: R 2 = 0.52, p = 0.001; DJ: R 2 = 0.25, p = 0.021). Conversely, LG-FL only demonstrates a significant and stronger predictive effect on AJ jump height (R 2 = 0.18, p = 0.009). Combining VL-ACSA, LG-FL, and training age through multiple linear regression analysis resulted in a highly significant model for predicting AJ jump height (F = 13.86, R 2 = 0.73). Moreover, the model incorporating VL-ACSA and training age is also important for predicting CMJ, SJ, and DJ jump heights (F = 8.41, R 2 = 0.51; F = 13.14, R 2 = 0.63; F = 5.95, R 2 = 0.41; respectively). Conclusion The muscle structure indicators in the lower limbs significantly predict jump performance among elite male volleyball players. However, different jump types are influenced by distinct indicators, particularly in the case of AJ, which is associated with LG-FL. This suggests that enhancing LG-FL may positively impact AJ ability, thereby emphasizing the importance of specificity in training. To optimize specialized jump performance in volleyball players, practitioners are advised to assess VL-ACSA and LG-FL and incorporate step-up and eccentric strength training targeting the calf muscles to yield considerable benefits.
Collapse
Affiliation(s)
- WeiDong Jiang
- School of Physical Education and Training, Shanghai University of Sport, Shanghai, China
| | - Chao Chen
- School of Competitive Sports, Shanghai University of Sport, Shanghai, China
| | - Yilin Xu
- Sports Biomechanics Laboratory, Jiangsu Research Institute of Sports Science, Nanjing, Jiangsu, China
| |
Collapse
|
3
|
Martin-Rodriguez S, Gonzalez-Henriquez JJ, Diaz-Conde JC, Calbet JAL, Sanchis-Moysi J. The relationship between muscle thickness and pennation angle is mediated by fascicle length in the muscles of the lower extremities. Sci Rep 2024; 14:14847. [PMID: 38937524 PMCID: PMC11211461 DOI: 10.1038/s41598-024-65100-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Accepted: 06/17/2024] [Indexed: 06/29/2024] Open
Abstract
Muscle morphological architecture, a crucial determinant of muscle function, has fascinated researchers since the Renaissance. Imaging techniques enable the assessment of parameters such as muscle thickness (MT), pennation angle (PA), and fascicle length (FL), which may vary with growth, sex, and physical activity. Despite known interrelationships, robust mathematical models like causal mediation analysis have not been extensively applied to large population samples. We recruited 109 males and females, measuring knee flexor and extensor, and plantar flexor MT, PA, and FL using real-time ultrasound imaging at rest. A mixed-effects model explored sex, leg (dominant vs. non-dominant), and muscle region differences. Males exhibited greater MT in all muscles (0.1 to 2.1 cm, p < 0.01), with no sex differences in FL. Dominant legs showed greater rectus femoris (RF) MT (0.1 cm, p = 0.01) and PA (1.5°, p = 0.01), while vastus lateralis (VL) had greater FL (1.2 cm, p < 0.001) and PA (0.6°, p = 0.02). Regional differences were observed in VL, RF, and biceps femoris long head (BFlh). Causal mediation analyses highlighted MT's influence on PA, mediated by FL. Moderated mediation occurred in BFlh, with FL differences. Gastrocnemius medialis and lateralis exhibited FL-mediated MT and PA relationships. This study unveils the intricate interplay of MT, FL, and PA in muscle architecture.
Collapse
Affiliation(s)
- Saul Martin-Rodriguez
- Department of Physical Education, University of Las Palmas de Gran Canaria, 35017, Las Palmas de Gran Canaria, Spain
- Research Institute of Biomedical and Health Sciences (IUIBS), 35017, Las Palmas de Gran Canaria, Canary Islands, Spain
| | - Juan Jose Gonzalez-Henriquez
- Research Institute of Biomedical and Health Sciences (IUIBS), 35017, Las Palmas de Gran Canaria, Canary Islands, Spain
- Department of Mathematics, University of Las Palmas de Gran Canaria, Las Palmas de Gran Canaria, Spain
| | - Juan Carlos Diaz-Conde
- Department of Physical Education, University of Las Palmas de Gran Canaria, 35017, Las Palmas de Gran Canaria, Spain
| | - Jose A L Calbet
- Department of Physical Education, University of Las Palmas de Gran Canaria, 35017, Las Palmas de Gran Canaria, Spain
- Research Institute of Biomedical and Health Sciences (IUIBS), 35017, Las Palmas de Gran Canaria, Canary Islands, Spain
- Department of Physical Performance, The Norwegian School of Sport Sciences, Postboks, 4014 Ulleval Stadion, 0806, Oslo, Norway
| | - Joaquin Sanchis-Moysi
- Department of Physical Education, University of Las Palmas de Gran Canaria, 35017, Las Palmas de Gran Canaria, Spain.
- Research Institute of Biomedical and Health Sciences (IUIBS), 35017, Las Palmas de Gran Canaria, Canary Islands, Spain.
| |
Collapse
|
4
|
Shams M, Karimi N, Vahedi M, Hakim PK, Zeinalkhani F, Rahnama L. Reliability of muscle stiffness measures in popliteus, medial and lateral gastrocnemius muscles by ultrasound shear wave elastography in participants with knee osteoarthritis accompanied by myofascial trigger points. BMC Musculoskelet Disord 2024; 25:221. [PMID: 38504204 PMCID: PMC10949787 DOI: 10.1186/s12891-024-07351-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 03/12/2024] [Indexed: 03/21/2024] Open
Abstract
BACKGROUND The objective of this investigation is to evaluate the consistency of intra-rater and inter-rater assessments utilizing ultrasound elastography to examine the muscle stiffness of the popliteus and gastrocnemius (medial and lateral heads) in patients with knee osteoarthritis accompanied by myofascial trigger points. METHODS Thirty individuals with knee osteoarthritis accompanied by myofascial trigger points were assessed. Two examiners independently measured the muscle stiffness levels of the popliteus and gastrocnemius (medial and lateral heads) three times using ultrasound elastography in the first session. The second session was conducted one week later. RESULTS In the initial test session, the mean shear modulus values for the popliteus and gastrocnemius (medial and lateral heads) muscles were measured as follows for tester 1 (12.75, 13.72, 14.13 kPa) and tester 2 (11.66, 12.81, 13.17 kPa). During the retest session, the previously measured variables by tester 1 and tester 2 yielded the following values: (12.61, 13.43, 14.26 kPa) and (11.62, 12.87, 13.30 kPa) respectively." Good to excellent intra-rater reliability (ICC = 0.912-0.986) and inter-rater reliability (ICC = 0.766-0.956) were reported for the shear moduli of the popliteus, medial and lateral gastrocnemius muscles. CONCLUSIONS The assessment of muscle stiffness in the popliteus and gastrocnemius (medial and lateral heads) using ultrasound elastography is a reliable method in patients with knee osteoarthritis accompanied by myofascial trigger points.
Collapse
Affiliation(s)
- Mohsen Shams
- Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| | - Noureddin Karimi
- Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
| | - Mohsen Vahedi
- Department of Biostatistics and Epidemiology, Substance Abuse and Dependence Research Center, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| | - Peyman Kamali Hakim
- Department of Radiology, Tehran University of Medical Sciences, Imam Khomeini Hospital, Tehran, Iran
| | - Fahimeh Zeinalkhani
- Department of Radiology, Tehran University of Medical Sciences, Imam Khomeini Hospital, Tehran, Iran
| | - Leila Rahnama
- Rongxiang Xu School of Health and Human Services, California State University, Los Angeles, Los Angeles, CA, USA
| |
Collapse
|
5
|
Lesinski M, Bashford G, Markov A, Risch L, Cassel M. Reliability of assessing skeletal muscle architecture and tissue organization of the gastrocnemius medialis and vastus lateralis muscle using ultrasound and spatial frequency analysis. Front Sports Act Living 2024; 6:1282031. [PMID: 38304420 PMCID: PMC10830747 DOI: 10.3389/fspor.2024.1282031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 01/05/2024] [Indexed: 02/03/2024] Open
Abstract
Introduction The purpose of this study was to investigate inter- and intra-rater reliability as well as the inter-rater interpretation error of ultrasound measurements assessing skeletal muscle architecture and tissue organization of the gastrocnemius medialis (GM) and vastus lateralis (VL) muscle. Methods The GM and VL of 13 healthy adults (22 ± 3 years) were examined thrice with sagittal B-mode ultrasound: intraday test-retest examination by one investigator (intra-rater) and separate examinations by two investigators (inter-rater). Additionally, images from one investigator were analysed by two interpretators (interpretation error). Muscle architecture was assessed by muscle thickness [MT], fascicle length [FL], as well as superior and inferior pennation angle [PA]. Muscle tissue organization was determined by spatial frequency analysis (SFA: peak spatial frequency radius, peak -6 dB width, PSFR/P6, normalized peak value of amplitude spectrum [Amax], power within peak [PWP], peak power percent). Reliability of ultrasound examination and image interpretation are presented as intraclass correlation coefficient (ICC), test-retest variability, standard error of measurement as well as bias and limits of agreement. Results GM and VL demonstrated excellent ICCs for inter- and intra-rater reliability, along with excellent ICCs for interpretation error of MT (0.91-0.99), showing minimal variability (<5%) and SEM% (<5%). Systematic bias for MT was less than 1 mm. For PA and FL poor to good ICCs for inter- and intra-rater reliability were revealed (0.41-0.90), with moderate variability (<12%), low SEM% (<10%) and systematic bias between 0.1-1.4°. Tissue organization analysis indicated moderate to good ICCs for inter- and intra-rater reliability. Notably, Amax and PWP consistently held the highest ICC values (0.77-0.87) across all analyses but with higher variability (<24%) and SEM% (<18%), compared to lower variability (<9%) and SEM% (<8%) in other tissue organization parameters. Interpretation error of all muscle tissue organization parameters showed excellent ICCs (0.96-0.999) with very low variability (≤1%) and SEM% (<2%), except Amax & PWP (TRV%: <6%; SEM%: <7%). Conclusion Our findings demonstrated excellent inter- and intra-rater reliability for MT. However, agreement for PA, FL, and SFA parameters was not as strong. Additionally, MT and all SFA parameters exhibited excellent agreement for inter-rater interpretation error. Therefore, the SFA seems to offer the possibility of objectively and reliably evaluating ultrasound images.
Collapse
Affiliation(s)
- Melanie Lesinski
- Division of Training and Movement Sciences, Research Focus Cognition Sciences, University of Potsdam, Potsdam, Germany
| | - Gregory Bashford
- Department of Biological Systems Engineering, University of Nebraska, Lincoln, NE, United States
| | - Adrian Markov
- Division of Training and Movement Sciences, Research Focus Cognition Sciences, University of Potsdam, Potsdam, Germany
| | - Lucie Risch
- Department of Sports Medicine, University Outpatient Clinic, University of Potsdam, Potsdam, Germany
| | - Michael Cassel
- Department of Sports Medicine, University Outpatient Clinic, University of Potsdam, Potsdam, Germany
| |
Collapse
|
6
|
Pelka EZ, Davis BR, Tomko PM, McDaniel J. Analysis of electrical stimulation and voluntary muscle contraction on skeletal muscle oxygen uptake and mitochondrial recovery using near-infrared spectroscopy. Eur J Appl Physiol 2023; 123:2053-2061. [PMID: 37171642 DOI: 10.1007/s00421-023-05221-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Accepted: 05/01/2023] [Indexed: 05/13/2023]
Abstract
PURPOSE This investigation was to compare differences in skeletal muscle oxygen consumption ([Formula: see text]) and mitochondrial recovery between voluntary (VOL) and electrically stimulated (ES) plantarflexion contractions. METHODS Twelve men and women (26 ± 4.0 years; 171.8 ± 5.1 cm; 74.0 ± 13.7 kg) were seated in a chair with their right knee fully extended and right foot secured to a force transducer. ES electrodes and a near-infrared spectroscopy device were placed on the gastrocnemius. Participants performed ES plantarflexion contractions across a range of stimulation intensities at frequencies of 1 and 2 Hz and similar VOL contractions. Cuff occlusion occurred immediately following each series of contractions to measure [Formula: see text]. A standardized mitochondrial function assessment protocol was also performed to calculate K-constants between work-matched ES and VOL contractions. RESULTS For mitochondrial assessments, there were no significant differences between ES and VOL rate constants (2.03 ± 0.98 vs. 1.25 ± 1.35 min-1, p = 0.266). ES resulted in a significantly greater workrate-[Formula: see text] slope at 1 Hz (0.007 ± 0.007 vs. 0.001 ± 0.002% [Formula: see text]/s/N, p = 0.014) and 2 Hz (0.010 ± 0.010 vs. 0.001 ± 0.001% [Formula: see text]/s/N, p = 0.012), as well as a significantly greater workrate-[Formula: see text] Y-intercept at 2 Hz (1.603 ± 1.513 vs. 0.556 ± 0.564% [Formula: see text]/s, p = 0.035) but not 1 Hz (0.579 ± 0.448 vs. 0.442 ± 0.357% mV̇O2/s, p = 0.535) when compared to VOL. CONCLUSION ES results in a significantly greater [Formula: see text] at similar work rates compared to VOL, however, the mitochondrial recovery rate constants were similar. The greater mVO2 with ES may partially contribute to the increased rate of fatigue during ES exercise in individuals with muscle paralysis.
Collapse
Affiliation(s)
- Edward Z Pelka
- Exercise Science and Exercise Physiology, Kent State University, OH, Kent, USA
| | - B Ryan Davis
- Exercise Science and Exercise Physiology, Kent State University, OH, Kent, USA
| | - Patrick M Tomko
- Exercise Science and Exercise Physiology, Kent State University, OH, Kent, USA
| | - John McDaniel
- Exercise Science and Exercise Physiology, Kent State University, OH, Kent, USA.
- Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, USA.
| |
Collapse
|
7
|
de Jesus Ferreira LG, de Almeida Ventura Á, da Silva Almeida I, Mansur H, Babault N, Durigan JLQ, de Cássia Marqueti R. Intra- and Inter-Rater Reliability and Agreement of Ultrasound Imaging of Muscle Architecture and Patellar Tendon in Post-COVID-19 Patients Who Had Experienced Moderate or Severe COVID-19 Infection. J Clin Med 2022; 11:jcm11236934. [PMID: 36498509 PMCID: PMC9738112 DOI: 10.3390/jcm11236934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 11/03/2022] [Accepted: 11/07/2022] [Indexed: 11/27/2022] Open
Abstract
COVID-19 is associated with musculoskeletal disorders. Ultrasound is a tool to assess muscle architecture and tendon measurements, offering an idea of the proportion of the consequences of the disease, since significant changes directly reflect the reduction in the ability to produce force and, consequently, in the functionality of the patient; however, its application in post-COVID-19 infection needs to be determined. We aimed to assess the intra- and inter-rater reliability of ultrasound measures of the architecture of the vastus lateralis (VL), rectus femoris (RF), vastus medialis (VM), gastrocnemius lateralis (GL), gastrocnemius medialis (GM), soleus (SO), and tibialis anterior (TA) muscles, as well as the patellar tendon (PT) cross-sectional area (CSA) in post-COVID-19 patients. An observational, prospective study with repeated measures was designed to evaluate 20 post-COVID-19 patients, who were measured for the pennation angle (θp), fascicular length (Lf), thickness, echogenicity of muscles, CSA and echogenicity of the PT. The intra-class correlation coefficient (ICC) and 95% limits of agreement were used. The intra-rater reliability presented high or very high correlations (ICC = 0.71-1.0) for most measures, except the θp of the TA, which was classified as moderate (ICC = 0.69). Observing the inter-rater reliability, all the evaluations of the PT, thickness and echogenicity of the muscles presented high or very high correlations. For the Lf, only the RF showed as low (ICC = 0.43), for the θp, RF (ICC = 0.68), GL (ICC = 0.70) and TA (ICC = 0.71) moderate and the SO (ICC = 0.40) low. The ultrasound reliability was acceptable for the muscle architecture, muscle and tendon echogenicity, and PT CSA, despite the low reliability for the Lf and θp of the RF and SO, respectively.
Collapse
Affiliation(s)
- Leandro Gomes de Jesus Ferreira
- Laboratory of Muscle and Tendon Plasticity, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
- Laboratory of Molecular Analysis, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
| | - Álvaro de Almeida Ventura
- Laboratory of Muscle and Tendon Plasticity, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
- Laboratory of Molecular Analysis, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
| | - Isabella da Silva Almeida
- Laboratory of Muscle and Tendon Plasticity, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
- Laboratory of Molecular Analysis, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
| | - Henrique Mansur
- Department of Orthopaedics, Hospital Santa Helena—Rede D’or, Sao Paulo 03313-000, Brazil
| | - Nicolas Babault
- Centre d’Expertise de la Performance, INSERM U1093 CAPS, Sports Science Faculty, University of Burgundy, 21000 Dijon, France
| | - João Luiz Quagliotti Durigan
- Laboratory of Muscle and Tendon Plasticity, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
- Laboratory of Molecular Analysis, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
- Graduate Program in Physical Education, Physical Education Department, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
| | - Rita de Cássia Marqueti
- Laboratory of Muscle and Tendon Plasticity, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
- Laboratory of Molecular Analysis, Graduate Program in Rehabilitation Science, Faculdade de Ceilândia, Universidade de Brasília, Distrito Federal, Brasília 70910-900, Brazil
- Correspondence: ; Tel./Fax: +55-61-3107-8401
| |
Collapse
|
8
|
Factors of Muscle Quality and Determinants of Muscle Strength: A Systematic Literature Review. Healthcare (Basel) 2022; 10:healthcare10101937. [PMID: 36292384 PMCID: PMC9601777 DOI: 10.3390/healthcare10101937] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 09/14/2022] [Accepted: 09/26/2022] [Indexed: 11/04/2022] Open
Abstract
Muscle quality defined as the ratio of muscle strength to muscle mass disregards underlying factors which influence muscle strength. The aim of this review was to investigate the relationship of phase angle (PhA), echo intensity (EI), muscular adipose tissue (MAT), muscle fiber type, fascicle pennation angle (θf), fascicle length (lf), muscle oxidative capacity, insulin sensitivity (IS), neuromuscular activation, and motor unit to muscle strength. PubMed search was performed in 2021. The inclusion criteria were: (i) original research, (ii) human participants, (iii) adults (≥18 years). Exclusion criteria were: (i) no full-text, (ii) non-English or -German language, (iii) pathologies. Forty-one studies were identified. Nine studies found a weak−moderate negative (range r: [−0.26]−[−0.656], p < 0.05) correlation between muscle strength and EI. Four studies found a weak−moderate positive correlation (range r: 0.177−0.696, p < 0.05) between muscle strength and PhA. Two studies found a moderate-strong negative correlation (range r: [−0.446]−[−0.87], p < 0.05) between muscle strength and MAT. Two studies found a weak-strong positive correlation (range r: 0.28−0.907, p < 0.05) between θf and muscle strength. Muscle oxidative capacity was found to be a predictor of muscle strength. This review highlights that the current definition of muscle quality should be expanded upon as to encompass all possible factors of muscle quality.
Collapse
|
9
|
Ritsche P, Schmid R, Franchi MV, Faude O. Agreement and reliability of lower limb muscle architecture measurements using a portable ultrasound device. Front Physiol 2022; 13:981862. [PMID: 36117694 PMCID: PMC9478722 DOI: 10.3389/fphys.2022.981862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 08/10/2022] [Indexed: 11/13/2022] Open
Abstract
High end ultrasonography devices lack in portability and are expensive. We investigated the agreement and reliability of a handheld and portable ultrasound system for human lower limb muscle architecture measurements. We captured ultrasound images of the rectus femoris (RF), vastus lateralis (VL) and gastrocnemius medialis (GM) in 36 active healthy participants (15 female, 21 male) at 50% of muscle length using the handheld Lumify (L12-4, linear-array 37 mm, Philips Healthcare, Amsterdam, Netherlands) and a high-end laboratory device (ACUSON Juniper, linear-array 54 mm, 12L3, SIEMENS Healthineers, Erlangen, Germany). We compared measurements of muscle fascicle length, pennation angle and thickness. To assess inter-session reliability of the Lumify system, participants were measured twice within 1 week. Comparing RF architecture measurements of both devices resulted in intra-class correlations (ICCs) ranging from 0.46–0.82 and standardized mean difference (SMDs) ranging from −0.45–0.05. For VL, ICCs ranged from 0.60–0.89 and SMDs ranged from −0.11–0.13. ICCs and SMDs for the GM ranged from 0.82–0.86 and −0.07–0.07. Calculating inter-session reliability for RF resulted in ICCs ranging from 0.44–0.76 and SMDs ranging from −0.38–0.15. For VL, ICCs and SMDs ranged from 0.57–0.75 and −0.13–0.02. ICCs for GM ranged from 0.75–0.92 and SMDs ranged from −0.15–0.16. Measurement of muscle thickness demonstrated the highest agreement (ICC ≥0.82) and reliability (ICC ≥0.75) across all muscles. The Lumify system was comparable to a high-end device and reliable for GM measurements. However, agreement and reliability were lower for the RF and VL. Of all evaluated architectural parameters, muscle thickness exhibited highest agreement and reliability.
Collapse
Affiliation(s)
- Paul Ritsche
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
- *Correspondence: Paul Ritsche,
| | - Reto Schmid
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
| | - Martino V. Franchi
- Department of Biomedical Sciences, University of Padova, Padua, Italy
- CIR-MYO Myology Center, University of Padova, Padua, Italy
| | - Oliver Faude
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
| |
Collapse
|
10
|
Wohlgemuth KJ, Blue MN, Mota JA. Reliability and accuracy of ultrasound image analyses completed manually versus an automated tool. PeerJ 2022; 10:e13609. [PMID: 35729910 PMCID: PMC9206842 DOI: 10.7717/peerj.13609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 05/28/2022] [Indexed: 01/17/2023] Open
Abstract
Analysis of Brightness-mode ultrasound-captured fascicle angle (FA) and fascicle length (FL) can be completed manually with computer-based programs or by automated programs. Insufficient data exists regarding reliability and accuracy of automated tools. Therefore, the purpose of this study was to determine the test-retest reliability of automatic and manual ultrasound analyses, while determining accuracy of the automatic tool against the manual equivalent. Twenty-three participants (mean ± SD; age = 24 ± 4 years; height = 172.2 ± 10.5 cm; body mass = 73.1 ± 16.1 kg) completed one laboratory visit consisting of two trials where vastus lateralis muscle architecture was assessed with ultrasound. Images were taken at both lower (10 MHz) and higher frequency (12 MHz). Images were analyzed manually in an open-source imaging program and automatically using a separate open-source macro function. Test-retest reliability statistics were calculated for automatic and manual analyses. Accuracy was determined with validity statistics and were calculated for automatic analyses. The results show that manual ultrasound analyses for FA and FL for both lower and higher frequency displayed good reliability (ICC2,1 = 0.75-0.86). However, automatic ultrasound analyses for FA and FL revealed moderate reliability (ICC2,1 = 0.61-0.72) for the lower frequency images and poor reliability (ICC2,1 = 0.16-0.27) for higher frequency images. When assessed against manual techniques, automatic analyses presented greater total error (TE) and standard error of the estimate (SEE) for FA at lower frequency (constant error (CE) = -3.91°, TE = 5.57°, SEE = 3.45°) than higher (CE = -2.78°, TE = -4.54°, SEE = 2.45°). For FL, the higher frequency error (CE = 0.92 cm, TE = 2.12 cm, SEE = 1.15 cm) was similar to lower frequency error (CE = 1.98 cm, TE = 3.66 cm, SEE = 1.57 cm). The findings overall show that manual analyses had good reliability and low absolute error, while demonstrating the automated counterpart had poor to moderate reliability and large errors in analyses. These findings may be impactful as they highlight the good reliability and low error associated with manually analyzed ultrasound images and validate a novel automatic tool for analyzing ultrasound images. Future work should focus on improving reliability and decreasing error in automated image analysis tools. Automated tools are promising for the field as they eliminate biases between analysts and may be more time efficient than manual techniques.
Collapse
Affiliation(s)
- Kealey J. Wohlgemuth
- Department of Kinesiology, University of Alabama - Tuscaloosa, Tuscaloosa, AL, United States
| | - Malia N.M Blue
- Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States
| | - Jacob A. Mota
- Department of Kinesiology, University of Alabama - Tuscaloosa, Tuscaloosa, AL, United States
| |
Collapse
|
11
|
May S, Locke S, Kingsley M. Gastrocnemius Muscle Architecture in Elite Basketballers and Cyclists: A Cross-Sectional Cohort Study. Front Sports Act Living 2021; 3:768846. [PMID: 34950871 PMCID: PMC8688802 DOI: 10.3389/fspor.2021.768846] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 10/27/2021] [Indexed: 12/29/2022] Open
Abstract
Eccentric and concentric actions produce distinct mechanical stimuli and result in different adaptations in skeletal muscle architecture. Cycling predominantly involves concentric activity of the gastrocnemius muscles, while playing basketball requires both concentric and eccentric actions to support running, jumping, and landing. The aim of this study was to examine differences in the architecture of gastrocnemius medialis (GM) and gastrocnemius lateralis (GL) between elite basketballers and cyclists. A trained sonographer obtained three B-mode ultrasound images from GM and GL muscles in 44 athletes (25 basketballers and 19 cyclists; 24 ± 5 years of age). The images were digitized and average fascicle length (FL), pennation angle (θ), and muscle thickness were calculated from three images per muscle. The ratio of FL to tibial length (FL/TL) and muscle thickness to tibial length (MT/TL) was also calculated to account for the potential scaling effect of stature. In males, no significant differences were identified between the athletic groups in all parameters in the GM, but a significant difference existed in muscle thickness in the GL. In basketballers, GL was 2.5 mm thicker (95% CI: 0.7-4.3 mm, p = 0.011) on the left side and 2.6 mm thicker (95% CI: 0.6-5.7 mm, p = 0.012) on the right side; however, these differences were not significant when stature was accounted for (MT/TL). In females, significant differences existed in the GM for all parameters including FL/TL and MT/TL. Female cyclists had longer FL in both limbs (MD: 11.2 and 11.3 mm), narrower θ (MD: 2.1 and 1.8°), and thicker muscles (MD: 2.1 and 2.5 mm). For the GL, female cyclists had significantly longer FL (MD: 5.2 and 5.8 mm) and narrower θ (MD: 1.7 and 2.3°) in both limbs; no differences were observed in absolute muscle thickness or MT/TL ratio. Differences in gastrocnemius muscle architecture were observed between female cyclists and basketballers, but not between males. These findings suggest that participation in sport-specific training might influence gastrocnemius muscle architecture in elite female athletes; however, it remains unclear as to whether gastrocnemius architecture is systematically influenced by the different modes of muscle activation between these respective sports.
Collapse
Affiliation(s)
- Samantha May
- La Trobe Rural Health School, La Trobe University, Bendigo, VIC, Australia
| | - Simon Locke
- La Trobe Rural Health School, La Trobe University, Bendigo, VIC, Australia
| | - Michael Kingsley
- Holsworth Research Initiative, La Trobe University, Bendigo, VIC, Australia.,Department of Exercise Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|