1
|
Engh CA, Bhal V, Hopper RH. Metal levels and glomerular filtration rate after unilateral Birmingham Hip Resurfacing. Bone Joint J 2024; 106-B:44-50. [PMID: 38423104 DOI: 10.1302/0301-620x.106b3.bjj-2023-0849.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Aims The first aim of this study was to evaluate whether preoperative renal function is associated with postoperative changes in whole blood levels of metal ions in patients who have undergone a Birmingham Hip Resurfacing (BHR) arthroplasty with a metal-on-metal bearing. The second aim was to evaluate whether exposure to increased cobalt (Co) and chromium (Cr) levels for ten years adversely affected renal function. Methods As part of a multicentre, prospective post-approval study, whole blood samples were sent to a single specialized laboratory to determine Co and Cr levels, and the estimated glomerular filtration rate (eGFR). The study included patients with 117 unrevised unilateral BHRs. There were 36 females (31%). The mean age of the patients at the time of surgery of 51.3 years (SD 6.5), and they all had preoperative one-, four-, five-, and ten-year laboratory data. The mean follow-up was 10.1 years (SD 0.2). Results Median Co levels at one year postoperatively increased significantly compared with the preoperative values, by a factor of 9.7, from 0.13 to 1.26 ppb (p < 0.001), and the median Cr levels increased significantly by a factor of 2.5, from 0.60 to 1.50 ppb (p < 0.001). Lower preoperative eGFRs were associated with significantly larger increases in Co at one year compared with the preoperative levels (ρ = -0.26; p = 0.005), but there was no relationship between preoperative eGFRs and changes in Cr at one year (ρ = -0.13; p = 0.153). Metal levels remained relatively constant with the passage of time, with a median ten-year value of 1.12 ppb for Co and 1.29 ppb for Cr. There was no significant relationship between the Co and Cr levels at ten-year follow-up and the change in eGFR from the preoperative level to that at ten years (ρ = -0.02; p = 0.827 for Co; ρ = -0.008; p = 0.933 for Cr). Conclusion Although patients with lower preoperative eGFRs tended to have larger increases in Co levels at one year, increased metal levels for patients who underwent unilateral BHR did not adversely affect renal function during the first ten postoperative years.
Collapse
Affiliation(s)
- Charles A Engh
- Anderson Orthopedic Clinic & Inova Mount Vernon Joint Replacement Center, Alexandria, Virginia, USA
| | - Vinay Bhal
- Edwards Lifesciences, Irvine, California, USA
| | - Robert H Hopper
- Anderson Orthopaedic Research Institute, Alexandria, Virginia, USA
| |
Collapse
|
2
|
Badhe RV, Akinfosile O, Bijukumar D, Barba M, Mathew MT. Systemic toxicity eliciting metal ion levels from metallic implants and orthopedic devices - A mini review. Toxicol Lett 2021; 350:213-224. [PMID: 34252509 DOI: 10.1016/j.toxlet.2021.07.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 06/19/2021] [Accepted: 07/07/2021] [Indexed: 12/28/2022]
Abstract
The metal/metal alloy-based implants and prostheses are in use for over a century, and the rejections, revisions, and metal particle-based toxicities were reported concurrently. Complications developed due to metal ions, metal debris, and organo-metallic particles in orthopedic patients have been a growing concern in recent years. It was reported that local and systemic toxicity caused by such released products from the implants is one of the major reasons for implant rejection and revision. Even though the description of environmental metal toxicants and safety limits for their exposure to humans were well established in the literature, an effort was not adequately performed in the case of implant-based metal toxicology. Since the metal ion concentration in serum acts as a possible indicator of the systemic toxicity, this review summarizes the reported human serum safe limits, toxic limits, and concentration range (μg/L, ppb, etc.) for mild to severe symptoms of six (cardiac, hepatic, neuro, nephron, dermal and endocrine) systemic toxicities for twelve most commonly used metallic implants. It also covers the widely used metal ion quantification techniques and systemic toxicity treatments reported.
Collapse
Affiliation(s)
- Ravindra V Badhe
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Obakanyin Akinfosile
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Divya Bijukumar
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | | | - Mathew T Mathew
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA.
| |
Collapse
|
3
|
Pozzuoli A, Berizzi A, Crimì A, Belluzzi E, Frigo AC, Conti GD, Nicolli A, Trevisan A, Biz C, Ruggieri P. Metal Ion Release, Clinical and Radiological Outcomes in Large Diameter Metal-on-Metal Total Hip Arthroplasty at Long-Term Follow-Up. Diagnostics (Basel) 2020; 10:diagnostics10110941. [PMID: 33198180 PMCID: PMC7698262 DOI: 10.3390/diagnostics10110941] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 11/10/2020] [Accepted: 11/11/2020] [Indexed: 02/08/2023] Open
Abstract
Total hip arthroplasty (THA) with metal-on-metal (MoM) bearings have shown problems of biocompatibility linked to metal ion release at the local level causing an adverse reaction to metal debris (ARMD) and at a systemic level. The aim of this study was to evaluate clinical and radiological outcomes, and metal ion concentrations in the blood and urine of patients who underwent THA with the LIMA Met-Met hip system. Patients with ceramic-on-ceramic (CoC) bearings were included as a control group. In this study, 68 patients were enrolled: 34 with MoM THAs and 34 with CoC THAs. Patients were evaluated clinically (Harris Hip Score, SF-36) and radiologically at a median of 7.4 years after surgery. Whole blood and urinary cobalt and chromium levels were also assessed. Both types of implants were comparable in terms of clinical and functional results. Ion levels were significantly higher in the MoM group compared with CoC group 7 years after surgery. No correlations were found between metal ion levels and patient demographics, functional and radiological outcomes, and prosthesis features. Patient monitoring is thus advised to establish if prosthesis revision is necessary, especially in the case of MoM THA.
Collapse
Affiliation(s)
- Assunta Pozzuoli
- Laboratory of Musculoskeletal Pathology and Oncology, Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy
- Correspondence: (A.P.); (E.B.); Tel.: +39-0498213348 (A.P. & E.B.)
| | - Antonio Berizzi
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Alberto Crimì
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Elisa Belluzzi
- Laboratory of Musculoskeletal Pathology and Oncology, Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy
- Correspondence: (A.P.); (E.B.); Tel.: +39-0498213348 (A.P. & E.B.)
| | - Anna Chiara Frigo
- Epidemiology and Public Health Unit, Department of Cardiac Thoracic Vascular Sciences and Public Health, Biostatistics, University of Padova, Via Loredan 18, 35131 Padova, Italy;
| | - Giorgio De Conti
- Department of Radiology, University Hospital of Padova, Via Giustiniani 2, 35128 Padova, Italy;
| | - Annamaria Nicolli
- Laboratory of Industrial Toxicology, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (A.N.); (A.T.)
| | - Andrea Trevisan
- Laboratory of Industrial Toxicology, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (A.N.); (A.T.)
| | - Carlo Biz
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Pietro Ruggieri
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| |
Collapse
|
4
|
Whole blood titanium metal ion measurement reproducibility of two laboratories. Pract Lab Med 2020; 21:e00167. [PMID: 32435683 PMCID: PMC7229280 DOI: 10.1016/j.plabm.2020.e00167] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 02/13/2020] [Accepted: 05/01/2020] [Indexed: 11/24/2022] Open
Abstract
Background Metal ion blood concentrations evaluation can be useful in monitoring wear and corrosion of orthopedic implants. Elevated metal ion level may help detecting defective hip arthroplasty implants and serve as an indicator for revision surgery. Our objective was to evaluate the reproducibility of titanium metal ion level measurements by two different laboratories. Methods Seventy-one whole blood samples were collected from 64 patients with unilateral ceramic-on-ceramic hip arthroplasty. For each patient, two whole blood samples were collected and analyzed in two different laboratories. Results For each case, laboratory 1 had significantly higher values than laboratory 2. There was a clinically significant absolute difference between the two laboratories, above the predetermined threshold, for 90% of samples. A mean variation ratio of 410% between the two laboratories was found. Conclusion Not all laboratories use the same techniques and calibrations to perform these measurements. Therefore, their results should be interpreted with caution and clinical decision should rely on metal ion trends provided by the same laboratory.
Collapse
|