Orhan ZD, Ciğerim L. Evaluation of Effect of Different Insertion Speeds and Torques on Implant Placement Condition and Removal Torque in Polyurethane Dense D1 Bone Model. Polymers (Basel) 2024; 16:1361. [PMID: 38794554 PMCID: PMC11125928 DOI: 10.3390/polym16101361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 05/05/2024] [Accepted: 05/07/2024] [Indexed: 05/26/2024] Open
Abstract
The aim of this study was to evaluate the effect of two different insertion speeds at eight different insertion torque values ranging from 25 to 60 during implantation in a dense polyurethane (PU) D1 bone model on the placement condition and removal torque of dental implants. In this study, 50 pcf single-layer PU plates were used. In the study, a total of 320 implant sockets were divided into two groups, Group 1 (30 rpm) and Group 2 (50 rpm), in terms of insertion speed. Group 1 and Group 2 were divided into eight subgroups with 25, 30, 35, 40, 45, 50, 55 and 60 torques. There were 20 implant sockets in each subgroup. During the implantations, the implant placement condition and removal torque values were assessed. There was a statistically significant difference between the 30 and 50 rpm groups in terms of overall implant placement condition (p < 0.01). It was found that the removal torque values at 50 rpm were statistically significantly higher than those at 30 rpm (p < 0.01). This study showed that in dense D1 bone, the minimum parameters at which all implants could be placed at the bone level were 50 torque at 30 rpm and 40 torque at 50 rpm.
Collapse
Affiliation(s)
| | - Levent Ciğerim
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Van Yuzuncu Yil University, Van 65090, Turkey;
| |
Collapse
|
2
|
Gottlow J, Sennerby L. Influence of diameter and length on primary stability in various implant site densities-An in vitro study in polyurethane blocks. Clin Implant Dent Relat Res 2024; 26:327-332. [PMID: 37926940 DOI: 10.1111/cid.13290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 10/12/2023] [Indexed: 11/07/2023]
Abstract
BACKGROUND The influence of dental implant length and diameter on primary stability in various bone densities is not well understood. AIM To in vitro study the effect of length and diameter on resonance frequency analysis (RFA), insertion torque (IT) and displacement (DP) measurements of dental implants in different implant site densities. MATERIALS AND METHODS Dental implants of four different diameters (Ø 3.5, 4.0, 4.5 and 5.0 mm) and three different lengths (7, 11 and 15 mm) (Neoss Ltd, Harrogate, UK) were placed in polyurethane blocks of three different densities (Sawbones Europe AB, Malmö, Sweden). The primary stability was assessed by RFA (ISQ) (Osstell, Osstell AB, Gothenburg, Sweden) and insertion torque measurements (ITmax in N cm) (iChiropo™, Bien-Air Dental SA, Bienne, Switzerland). In addition, the blocks were mounted in a rig and a lateral force of 25 N cm was applied to the implants and the DP was measured in μm with a micrometer gauge placed on the opposite side of the load transducer. Statistical analyses using linear and quadratic models were applied. RESULTS Implant length, diameter and block density were found to be significant independent predictors of RFA, ITmax, and DP measurements. Implant length had a strong effect, while the effect of diameter in general was subtle, particularly in the softest block. CONCLUSIONS Implant length affects primary stability more than implant diameter in polyurethane blocks of uniform density along the whole length of the tested implants.
Collapse
Affiliation(s)
- Johan Gottlow
- Department of Oral and Maxillofacial Surgery, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Lars Sennerby
- Department of Oral and Maxillofacial Surgery, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
3
|
You S, Yu F, Fan Q, Xia T, Liang L, Yan Q, Zeng H, Shi B. Radiographic comparison of atelocollagen versus deproteinized bovine bone minerals covered with a collagen membrane in alveolar ridge preservation: a retrospective study. BMC Oral Health 2023; 23:901. [PMID: 37990178 PMCID: PMC10662564 DOI: 10.1186/s12903-023-03647-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 11/09/2023] [Indexed: 11/23/2023] Open
Abstract
BACKGROUND Atelocollagen (AC) is a low-immunogenic collagen derivative with longer degradation time, which can be a suitable material for alveolar ridge preservation (ARP). However, there are few human studies on AC using for ARP. This research aims to radiographically evaluate the efficacy of AC in comparison to deproteinized bovine bone minerals covered with a collagen membrane (DBBM/CM) in ARP. METHODS Medical records in the Implantology Department of the Hospital of Stomatology of Wuhan University were screened for patients who received flapless ARP using either AC or DBBM/CM. A total of 58 patients were included in this retrospective study. 28 patients were treated with AC, while 30 patients were used DBBM/CM. Cone-beam computed tomography (CBCT) scans were taken before extraction and after 6 months of healing. To assess the dimensional change of the extraction sockets, the scanning data were output and transferred to the digital software to measure horizontal bone width change, vertical bone height change and bone volume change in region of interest. To evaluate the bone quality of healed sockets, the bone density of virtual implants was evaluated. RESULTS The horizontal bone width changes at all five different levels showed no significant difference between the two groups. The largest horizontal bone width decrement in both groups occurred at the crest of ridge, which decreased 3.71 ± 1.67 mm in AC group and 3.53 ± 1.51 mm in DBBM/CM group (p = 0.68). At the central buccal aspect, the ridge height reduced 0.10 ± 1.30 mm in AC group, while increased 0.77 ± 2.43 mm in DBBM/CM group (p = 0.10). The vertical bone height differences between two groups showed no statistical significance. The percentages of volume absorption in AC group and DBBM/CM group were 12.37%±6.09% and 14.54%±11.21%, respectively. No significant difference in volume absorption was found (p = 0.36). The average bone density around virtual implants in AC group (649.41 ± 184.71 HU) was significantly lower than that in DBBM/CM group (985.23 ± 207.85 HU) (p < 0.001). CONCLUSIONS ARP with AC had a similar effect on limiting the dimensional alteration of alveolar ridge, when radiographically compared with DBBM/CM.
Collapse
Affiliation(s)
- Sha You
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Fan Yu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Qihang Fan
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
- Department of Implantology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Ting Xia
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
- Department of Implantology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Liang Liang
- Department of Oral Implantology, Jianli Stomatology Hospital, Dongguan, China
| | - Qi Yan
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
- Department of Implantology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Hao Zeng
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
- Department of Implantology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
| | - Bin Shi
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
- Department of Implantology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
| |
Collapse
|
4
|
Lee SH, Yun PY, Yi YJ, Kim YK, Lee HJ, Jo DW. Low Bone Density Predictability of CBCT and Its Relation to Primary Stability of Tapered Implant Design: A Pilot Study. J ORAL IMPLANTOL 2023; 49:556-563. [PMID: 35881816 DOI: 10.1563/aaid-joi-d-21-00159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Revised: 04/04/2022] [Accepted: 05/31/2022] [Indexed: 11/22/2022]
Abstract
Research regarding bone density assessment using cone beam computed tomography (CBCT) in low bone density regions is sparse. This in vitro study aimed to evaluate the predictability of CBCT for low bone density regions and its correlations with primary implant stability when placing tapered design implants with a stepped osteotomy. Eighteen porcine mandibular condyles were used as simulated low bone density regions. Hounsfield units (HU), obtained via multislice computed tomography, and gray values (GVs), obtained via CBCT, were measured 3 times at 1-month intervals. The maximum implant insertion torque (MIT) and implant stability quotient (ISQ) were recorded as the taper design implants were placed using a stepped osteotomy. Hounsfield units and GV were measured as 335.05-803.07 and 389.98-906.40, respectively. For repeated measurements of HU and GV, the intraclass correlation coefficients were 0.989 and 0.980; the corresponding value for mean HU and GV was 0.768. Bland-Altman plots showed a mean difference between HU and GV of -78.15. Pearson correlation coefficients revealed a strong correlation between HU and GV (r = 0.91, P < .01). The mean ± SD values for MIT and ISQ were 36.44 ± 6.64 Ncm and 80.85 ± 2.03, respectively, but no statistically significant correlations were found with GV and HU. Within the study's limitations, GV showed similar bone density estimation compared with HU in soft bones. Tapered implant placement with a stepped osteotomy achieved stable primary implant stability in soft bones. However, these in vitro results need to be approved in further clinical studies.
Collapse
Affiliation(s)
- Sang-Hoon Lee
- Department of Prosthodontics, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Pil-Young Yun
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
- Department of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Yang-Jin Yi
- Department of Prosthodontics, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
- Department of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Young-Kyun Kim
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Hyo-Jung Lee
- Department of Periodontology, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Deuk-Won Jo
- Department of Prosthodontics, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| |
Collapse
|
5
|
Rosas-Díaz JC, Malpartida-Carrillo V, Córdova-Limaylla NE, Guerrero ME, Palomino-Zorrilla JJ, Cervantes-Ganoza LA, Cayo-Rojas CF. Resonance Frequency Analysis Mapping During Implant Healing Using a Nanostructured Hydroxyapatite Surface. J Int Soc Prev Community Dent 2023; 13:365-372. [PMID: 38124725 PMCID: PMC10729884 DOI: 10.4103/jispcd.jispcd_265_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/02/2021] [Accepted: 10/16/2021] [Indexed: 11/11/2022] Open
Abstract
Aim Stability measured by resonance frequency analysis (RFA) is an important factor to be considered in the success of dental implant treatments, which can be evaluated from the implant stability quotient (ISQ). The aim of the present case series was to map the RFA during healing of implants with nanostructured hydroxyapatite surface to describe the behavior of ISQ values related to individual factors. Materials and Methods Twenty-three implants were placed in eight patients by conventional surgical protocol, and ISQ values were monitored from the day of implant placement until week 20. To obtain the ISQ values, an Osstell device was used and the placed implants were grouped in proportional amounts to describe the ISQ behavior considering the length (≤10 or >10 mm), the diameter (3.5 or 4.3 mm), the insertion torque (<40 N-cm or ≥40 N-cm), and the placement area (maxilla or mandible). Results All the implants assessed decreased their values in the first 3 weeks after placement. Subsequently, the ISQ values increased by amounts similar to those obtained at the time of the placement and even more. Implants with length >10 mm, diameter 4.3 mm, and insertion torque ≥40 N-cm showed the highest ISQ values. Conclusions A decrease in the ISQ values of dental implants with nanostructured hydroxyapatite surface was evidenced between weeks 2 and 3 considering length, diameter, insertion torque, and maxillary or mandibular placement site.
Collapse
Affiliation(s)
| | | | | | - Maria Eugenia Guerrero
- Faculty of Dentistry, Universidad Nacional Mayor de San Marcos, Department of Medico Surgical Stomatology, Lima, Peru
| | | | | | | |
Collapse
|
6
|
Herrero-Climent M, Falcao A, Tondela J, Brizuela A, Rios-Carrasco B, Gil J. Relevant Aspects of the Dental Implant Design on the Insertion Torque, Resonance Frequency Analysis (RFA) and Micromobility: An In Vitro Study. J Clin Med 2023; 12:jcm12030855. [PMID: 36769501 PMCID: PMC9917810 DOI: 10.3390/jcm12030855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 12/30/2022] [Accepted: 01/19/2023] [Indexed: 01/24/2023] Open
Abstract
The major problems for the osseointegration of dental implants are the loosening of the screw that fixes the dental implant to the abutment and the micromovements that are generated when mechanical loads are applied. In this work, torque differences in the tightening and loosening of the connection screws after 1 cycle, 10 cycles and 1000 cycles for 4 dental implants with 2 external and 2 internal connections were analyzed. The loosening of 240 implants (60 for each system) was determined using high-precision torsimeters and an electromechanical testing machine. A total of 60 dental implants for each of the 4 systems were inserted into fresh bovine bone to determine the micromovements. The implant stability values (ISQ) were determined by RFA. The mechanical loads were performed at 30° from 20 N to 200 N. By means of the Q-star technique, the micromovements were determined. It was observed that, for a few cycles, the loosening of the screw did not exceed a loss of tightening of 10% for both connections. However, for 1000 cycles, the loss for the external connection was around 20% and for the internal connection it was 13%. The micromovements showed a lineal increase with the applied load for the implant systems studied. An external connection presented greater micromotions for each level of applied load and lower ISQ values than internal ones. An excellent lineal correlation between the ISQ and micromobility was observed. These results may be very useful for clinicians in the selection of the type of dental implant, depending on the masticatory load of the patient as well as the consequences of the insertion torque of the dental implant and its revisions.
Collapse
Affiliation(s)
| | - Artur Falcao
- Porto Dental Institute, Av. de Montevideu 810, 4150-518 Porto, Portugal
| | - Joao Tondela
- Centre for Innovation and Research in Oral Sciences (CIROS), Faculty of Medicine, University of Coimbra, Rua Larga 2, 3004-531 Coimbra, Portugal
| | - Aritza Brizuela
- Facultad de Odontología, Universidad Europea Miguel de Cervantes, C/del Padre Julio Chevalier 2, 47012 Valladolid, Spain
| | - Blanca Rios-Carrasco
- Department of Periodontology, Faculty of Dentsitry, University of Seville, 41009 Sevilla, Spain
| | - Javier Gil
- Bioengineering Institute of Technology, Facultad de Medicina y Ciencias de la Salud, International University of Catalonia, Sant Cugat del Vallés, 08195 Barcelona, Spain
- Correspondence:
| |
Collapse
|
7
|
Bandela V, Shetty N, Munagapati B, Basany RB, Kanaparthi S. Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study. Cureus 2022; 14:e30843. [DOI: 10.7759/cureus.30843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/29/2022] [Indexed: 11/06/2022] Open
|
8
|
Raz P, Meir H, Levartovsky S, Sebaoun A, Beitlitum I. Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:3072. [PMID: 35591407 PMCID: PMC9104754 DOI: 10.3390/ma15093072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 03/23/2022] [Accepted: 04/21/2022] [Indexed: 02/05/2023]
Abstract
Primary implant stability can be evaluated at the time of placement by measuring the insertion torque (IT). However, another method to monitor implant stability over time is resonance frequency analysis (RFA). Our aim was to examine the effect of bone type, implant design, and implant length on implant primary stability as measured by IT and two RFA devices (Osstell and Penguin) in an in vitro model. Ninety-six implants were inserted by a surgical motor in an artificial bone material, resembling soft and dense bone. Two different implant designs-conical connection (CC) and internal hex (IH), with lengths of 13 and 8 mm, were compared. The results indicate that the primary stability as measured by RFA and IT is significantly increased by the quality of bone (dense bone), and implant length and design, where the influence of dense bone is similar to that of CC design. Both the Osstell and Penguin devices recorded higher primary implant stability for long implants in dense bone, favoring the CC over the IH implant design. The CC implant design may compensate for the low stability expected in soft bone, and dense bone may compensate for short implant length if required by the anatomical bone conditions.
Collapse
Affiliation(s)
- Perry Raz
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel; (H.M.); (A.S.); (I.B.)
| | - Haya Meir
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel; (H.M.); (A.S.); (I.B.)
| | - Shifra Levartovsky
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel;
| | - Alon Sebaoun
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel; (H.M.); (A.S.); (I.B.)
| | - Ilan Beitlitum
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel; (H.M.); (A.S.); (I.B.)
| |
Collapse
|
9
|
Heitzer M, Kniha K, Katz MS, Winnand P, Peters F, Möhlhenrich SC, Hölzle F, Modabber A. The primary stability of two dental implant systems in low-density bone. Int J Oral Maxillofac Surg 2022; 51:1093-1100. [PMID: 35339332 DOI: 10.1016/j.ijom.2022.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 02/18/2022] [Accepted: 02/23/2022] [Indexed: 11/19/2022]
Abstract
Primary stability in low-density bone is crucial for the long-term success of implants. Tapered implants have shown particularly favourable properties under such conditions. The aim of this study was to compare the primary stability of tapered titanium and novel cylindrical zirconia dental implant systems in low-density bone. Fifty implants (25 tapered, 25 cylindrical) were placed in the anterior maxillary bone of cadavers meeting the criteria of low-density bone. The maximum insertion (ITV) and removal (RTV) torque values were recorded, and the implant stability quotients (ISQ) determined. To establish the isolated influence of cancellous bone on primary stability, the implantation procedure was performed in standardized low-density polyurethane foam bone blocks (cancellous bone model) using the same procedure. The primary stability parameters of both implant types showed significant positive correlations with bone density (Hounsfield units) and cortical thickness. In the cadaver, the cylindrical zirconia implants showed a significantly higher mean ISQ when compared to the tapered titanium implants (50.58 vs 37.26; P < 0.001). Pearson analysis showed significant positive correlations between ITV and ISQ (P = 0.016) and between RTV and ISQ (P = 0.035) for the cylindrical zirconia implants; no such correlations were observed for the tapered titanium implants. Within the limitations of this study, the results indicate that cylindrical zirconia implants represent a comparable viable treatment option to tapered titanium implants in terms of primary implant stability in low-density human bone.
Collapse
Affiliation(s)
- M Heitzer
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany.
| | - K Kniha
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - M S Katz
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - P Winnand
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - F Peters
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - S C Möhlhenrich
- Department of Orthodontics, University of Witten/Herdecke, Witten, Germany
| | - F Hölzle
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - A Modabber
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| |
Collapse
|
10
|
Molar Septum Expansion with Osseodensification for Immediate Implant Placement, Retrospective Multicenter Study with Up-to-5-Year Follow-Up, Introducing a New Molar Socket Classification. J Funct Biomater 2021; 12:jfb12040066. [PMID: 34940545 PMCID: PMC8708493 DOI: 10.3390/jfb12040066] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 11/22/2021] [Accepted: 11/23/2021] [Indexed: 12/16/2022] Open
Abstract
The ideal positioning of immediate implants in molar extraction sockets often requires the osteotomy to be in the interradicular septum, which can be challenging in some cases, with traditional site preparation techniques. Patients who had undergone molar tooth extraction and immediate implant placement at five different centers, and followed up between August 2015 and September 2020, were evaluated. Inclusion criteria were use of the osseodensification technique for implant site preparation. The primary outcome was septum width measurement pre-instrumentation and osteotomy diameter post expansion. Clinical outcomes, such as implant insertion torque (ISQ) and implant survival rate, were also collected. A total of 131 patients, who received 145 immediate implants, were included. The mean overall septum width at baseline was 3.3 mm and the mean osteotomy diameter post instrumentation was 4.65 mm. A total of ten implants failed: seven within the healing period and three after loading; resulting in a cumulative implant survival rate of 93.1%. This retrospective study showed that osseodensification is a predictable method for immediate implant placement with interradicular septum expansion in molar extraction sockets. Furthermore, it allowed the introduction of a new molar socket classification. In the future, well-designed controlled clinical studies are needed to confirm these results and further explore the potential advantages of this technique.
Collapse
|
11
|
Can the design of the instruments used for undersized osteotomies influence the initial stability of implants installed in low-density bone? An in vitro pilot study. PLoS One 2021; 16:e0257985. [PMID: 34618848 PMCID: PMC8496820 DOI: 10.1371/journal.pone.0257985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 09/14/2021] [Indexed: 12/11/2022] Open
Abstract
Objectives The aims of this study were to compare the initial implant stability obtained using four different osteotomy techniques in low-density synthetic bone, to evaluate the instrument design in comparison to the implant design, and to determinate a possible correlation between the insertion torque and initial stability quotient (ISQ). Materials and methods Four groups were identified in accordance with the osteotomy technique used (n = 10 implants per group): group G1, osteotomy using the recommended drilling sequence; group G2, osteotomy using an undersized compactor drill; group G3, osteotomy using an undersized drill; and group G4, osteotomy using universal osseodensification drills. Two polyurethane blocks were used: block 1, with a medullary portion of 10 pounds per cubic foot (PCF 10) and with a 1 mm cortical portion of PCF 40, and block 2, with a medullary of PCF 15 and with a 2 mm cortical portion of PCF 40. Tapered implants of 4 mm in diameter and 11 mm in length were used. The insertion torque (IT) and ISQ were measured. The dimensions of the final instrument used in each group and the dimensions of the implant were used to calculate the total area of each part, and these data were compared. Results Differences between the four groups were found for IT and ISQ values depending on the technique used for the osteotomy in the two synthetic bone models (p < 0.0001). All groups showed lower values of initial stability in block 1 than in block 2. Conclusions Undersized osteotomies with instruments designed according to the implant body significantly increased the initial stability values compared to beds prepared with universal drills and using the drilling sequence standardized by the manufacturer.
Collapse
|
12
|
Raz P, Meir H, Levartovsky S, Peleg M, Sebaoun A, Beitlitum I. Reliability and Correlation of Different Devices for the Evaluation of Primary Implant Stability: An In Vitro Study. MATERIALS 2021; 14:ma14195537. [PMID: 34639933 PMCID: PMC8509803 DOI: 10.3390/ma14195537] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 09/13/2021] [Accepted: 09/14/2021] [Indexed: 12/14/2022]
Abstract
Our aim was to analyze the correlation between the IT evaluated by a surgical motor and the primary implant stability (ISQ) measured by two RFA devices, Osstell and Penguin, in an in vitro model. This study examines the effect of bone type (soft or dense), implant length (13 mm or 8 mm), and implant design (CC: conical connection; IH: internal hexagon), on this correlation. Ninety-six implants were inserted using a surgical motor (IT) into two types of synthetic foam blocks. Initial measurements for both the peak IT and ISQ were recorded at the point when implant insertion was stopped by the surgical motor, and the final measurements were recorded when the implant was completely inserted into the synthetic blocks using only the RFA devices. Our null hypothesis was that there is a good correlation between the devices, independent of the implant length, design, or bone type. We found a positive, significant correlation between the IT, and the Osstell and Penguin devices. Implant length and bone type did not affect this correlation. The correlation between the devices in the CC design was maintained; however, in the IH design it was maintained only between the RFA devices. We concluded that there is a high positive correlation between the IT and ISQ from a mechanical perspective, which was not affected by bone type or implant length but was affected by the implant design.
Collapse
Affiliation(s)
- Perry Raz
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (H.M.); (A.S.); (I.B.)
- Correspondence:
| | - Haya Meir
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (H.M.); (A.S.); (I.B.)
| | - Shifra Levartovsky
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Maia Peleg
- The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Alon Sebaoun
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (H.M.); (A.S.); (I.B.)
| | - Ilan Beitlitum
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (H.M.); (A.S.); (I.B.)
| |
Collapse
|
13
|
Silva R, Villalón P, Cáceres F. Effect of macro-design in the primary stability of short and extra-short implants using resonance frequency analysis. An ex vivo study. J Oral Biol Craniofac Res 2020; 10:603-607. [PMID: 32953443 DOI: 10.1016/j.jobcr.2020.08.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 08/22/2020] [Accepted: 08/28/2020] [Indexed: 12/30/2022] Open
Abstract
Objective This study aimed to determine the effect of macro design in the primary stability of short and extra-short implants using resonance frequency analysis (RFA). Material and methods On an ex-vivo model using pig's ribs, we inserted 80 short and extra-short dental implants (20 implants per brand): Biohorizons®(B) 4.6 × 6mm; Intralock®(I) 4.75 × 6.5 mm; Straumann®(S) 4.1 × 4mm; and Tixos®(T) 5 × 5mm. Primary implant stability was measured using an RFA device. We compared mean ISQ values through ANOVA test. Results Mean ISQ values: B = 73.36 (±3.39); I = 75.13 (±3.88); S = 65.38 (±8.38); T = 72.13 (±11). B and I showed higher ISQ than S (p-value < 0.001). Short (I) showed higher ISQ than extra-short (B,S,T) implants (p-value = 0.001). Tapered (B,I) had higher ISQ than parallel (S,T) implants (p-value < 0.001). There was a moderate positive correlation between ISQ and length (r = 0.52), and a weak correlation with diameter (r = 0.33). Discussion The final result is a combination of implant design, length, and diameter. Tapered design (B and I) and larger implants (I) showed better primary stability in terms of ISQ values. This information could be beneficial at implant selection in a severely reabsorbed low-quality bone, privileging length (as long as it is safe), and conical walls design.
Collapse
Affiliation(s)
- Ramón Silva
- Department of Implant Dentistry, Facultad de Odontología, Universidad de los Andes, Monseñor Álvaro del Portillo 12455, 7620001, Las Condes, Santiago, Chile
| | - Pablo Villalón
- Department of Implant Dentistry, Facultad de Odontología, Universidad de los Andes, Monseñor Álvaro del Portillo 12455, 7620001, Las Condes, Santiago, Chile
| | - Felipe Cáceres
- Department of Implant Dentistry, Facultad de Odontología, Universidad de los Andes, Monseñor Álvaro del Portillo 12455, 7620001, Las Condes, Santiago, Chile
| |
Collapse
|