Li X, Zhao YC, Yin D, Cai Y, Xiao D, Zhao MC, Wen C, Atrens A. Microwave-Sintered Nano-SiC Reinforced 8SiC/Ti-3Cu Composite: Fabrication, Wear Resistance, Antibacterial Function, and Biocompatibility. Adv Healthc Mater 2025; 14:e2403626. [PMID: 39757472 DOI: 10.1002/adhm.202403626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2024] [Revised: 12/21/2024] [Indexed: 01/07/2025]
Abstract
The significance of biomedical applications of Ti alloys is best emphasized by their widespread utilization as implantable materials, such as internal supports and bone replacements. Ti alloys are sensitive to fretting wear, which leads to the early failure of Ti implants. Improved wear resistance of such implants is essential to ensure a prolonged implant life. Based on the structure-function-integrated concept, this work unprecedentedly designs and fabricates an antibacterial 8SiC/Ti-3Cu composite with improved wear resistance using microwave sintering from pure Ti, Cu, and nano-SiC powders. For comparison, SiC-free Ti-3Cu composite is manufactured under the same conditions using microwave sintering. The addition of 8 vol.% SiC to Ti-3Cu significantly reduces the porosity and pore size of composites. The 8SiC/Ti-3Cu shows a Vickers hardness of 353 HV, compressive strength of 803 MPa, elastic modulus of 28.7 GPa, and a significantly increased wear resistance (wear rate decreased by 70% compared to Ti-3Cu). In addition, 8SiC/Ti-3Cu exhibits excellent electrochemical corrosion resistance, biocompatibility in relation to MC3T3-E1 cells, and a bacteriostatic rate over 99% against E. coli. The combination of the wear-resistant nano-reinforced SiC and antibacterial Ti2Cu in the 8SiC/Ti-3Cu composite renders it a highly promising implant material.
Collapse
Affiliation(s)
- Xin Li
- School of Materials Science and Engineering, Central South University, Changsha, 410083, China
| | - Ying-Chao Zhao
- School of Materials Science and Engineering, Central South University, Changsha, 410083, China
| | - Dengfeng Yin
- School of Materials Science and Engineering, Central South University, Changsha, 410083, China
| | - Ying Cai
- Xiangya Hospital, Central South University, Changsha, 410008, China
| | - Desheng Xiao
- Xiangya Hospital, Central South University, Changsha, 410008, China
| | - Ming-Chun Zhao
- School of Materials Science and Engineering, Central South University, Changsha, 410083, China
| | - Cuie Wen
- Centre for Additive Manufacturing, School of Engineering, RMIT University, Melbourne, 3001, Australia
| | - Andrej Atrens
- School of Mechanical and Mining Engineering, University of Queensland, Brisbane, QLD4072, Australia
| |
Collapse
|
2
|
de Campos Kajimoto N, de Paiva Buischi Y, Mohamadzadeh M, Loomer P. The Oral Microbiome of Peri-Implant Health and Disease: A Narrative Review. Dent J (Basel) 2024; 12:299. [PMID: 39452426 PMCID: PMC11506630 DOI: 10.3390/dj12100299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Revised: 09/11/2024] [Accepted: 09/20/2024] [Indexed: 10/26/2024] Open
Abstract
Peri-implantitis disease has increased significantly over the last years, resulting in increased failure of implants. Many factors may play a role in implant complications and failure, including ones related to the oral microbiota. This literature review aims to summarize the current knowledge of microbiome of implants in health and disease, focusing not only on the presence/absence of specific microbiota or on their relative abundance, but also on their phenotypic expression and their complex relationships with the host. The authors examined the MEDLINE database and identified key topics about peri-implant oral microbiome in health and disease. The peri-implant microbiome differs from that of the tooth, both in health and disease, as they are structurally and chemically different. The adhesion and formation of the peri-implant biofilm can be affected by the surface energy, topography, wettability, and electrochemical charges of the implant surface. In addition, the morphogenesis of the tissues surrounding the dental implant also differs from the tooth, making the dental implant more susceptible to bacterial infection. This interplay between the microbiome and the host immune system in peri-implant infections still needs to be elucidated.
Collapse
Affiliation(s)
- Natalia de Campos Kajimoto
- Department of Periodontics, The University of Texas Health Science Center at San Antonio, San Antonio, TX 78229, USA; (N.d.C.K.); (Y.d.P.B.)
| | - Yvonne de Paiva Buischi
- Department of Periodontics, The University of Texas Health Science Center at San Antonio, San Antonio, TX 78229, USA; (N.d.C.K.); (Y.d.P.B.)
| | - Mansour Mohamadzadeh
- Department of Microbiology, Immunology & Molecular Genetics, The University of Texas Health Science Center at San Antonio, San Antonio, TX 78229, USA;
| | - Peter Loomer
- Department of Periodontics, The University of Texas Health Science Center at San Antonio, San Antonio, TX 78229, USA; (N.d.C.K.); (Y.d.P.B.)
| |
Collapse
|
3
|
Domingo MG, Kurtz M, Maglione G, Martin M, Brites F, Tasat DR, Olmedo DG. Chronic exposure to TiO 2 micro- and nano particles: A biochemical and histopathological experimental study. J Biomed Mater Res B Appl Biomater 2024; 112:e35443. [PMID: 38968028 DOI: 10.1002/jbm.b.35443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 04/08/2024] [Accepted: 06/09/2024] [Indexed: 07/07/2024]
Abstract
The aim of this work was to analyze the effects of long-term exposure to titanium dioxide (TiO2) micro- (MPs) and nanoparticles (NPs) (six and 12 months) on the biochemical and histopathological response of target organs using a murine model. Male Wistar rats were intraperitoneally injected with a suspension of TiO2 NPs (5 nm; TiO2-NP5 group) or MPs (45 μm; TiO2-NP5 group); the control group was injected with saline solution. Six and 12 months post-injection, titanium (Ti) concentration in plasma and target organs was determined spectrometrically (ICP-MS). Blood smears and organ tissue samples were evaluated by light microscopy. Liver and kidney function was evaluated using serum biochemical parameters. Oxidative metabolism was assessed 6 months post-injection (determination of superoxide anion by nitroblue tetrazolium (NBT) test, superoxide dismutase (SOD) and catalase (CAT), lipid peroxidation, and paraoxonase 1). Titanium (Ti) concentration in target organs and plasma was significantly higher in the TiO2-exposed groups than in the control group. Histological evaluation showed the presence of titanium-based particles in the target organs, which displayed no structural alterations, and in blood monocytes. Oxidative metabolism analysis showed that TiO2 NPs were more reactive over time than MPs (p < .05) and mobilization of antioxidant enzymes and membrane damage varied among the studied organs. Clearance of TiO2 micro and nanoparticles differed among the target organs, and lung clearance was more rapid than clearance from the lungs and kidneys (p < .05). Conversely, Ti concentration in plasma increased with time (p < .05). In conclusion, neither serum biochemical parameters nor oxidative metabolism markers appear to be useful as biomarkers of tissue damage in response to TiO2 micro- and nanoparticle deposits at chronic time points.
Collapse
Affiliation(s)
- Mariela Gisele Domingo
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica, Buenos Aires, Argentina
- Becario de Investigación de la Universidad de Buenos Aires, Buenos Aires, Argentina
| | - Melisa Kurtz
- CONICET, Buenos Aires, Argentina
- Instituto de Tecnologías Emergentes y Ciencias Aplicadas (ITECA), Escuela de Ciencia y Tecnología, Universidad Nacional de San Martín-CONICET, Buenos Aires, Argentina
| | - Guillermo Maglione
- Instituto de Tecnologías Emergentes y Ciencias Aplicadas (ITECA), Escuela de Ciencia y Tecnología, Universidad Nacional de San Martín-CONICET, Buenos Aires, Argentina
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Histología y Embriología, Buenos Aires, Argentina
| | | | - Fernando Brites
- CONICET, Buenos Aires, Argentina
- Universidad de Buenos Aires, Facultad de Farmacia y Bioquímica, Departamento de Bioquímica Clínica, Laboratorio de Lípidos y Lipoproteínas, Buenos Aires, Argentina
| | - Deborah Ruth Tasat
- Instituto de Tecnologías Emergentes y Ciencias Aplicadas (ITECA), Escuela de Ciencia y Tecnología, Universidad Nacional de San Martín-CONICET, Buenos Aires, Argentina
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Histología y Embriología, Buenos Aires, Argentina
| | - Daniel Gustavo Olmedo
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica, Buenos Aires, Argentina
- CONICET, Buenos Aires, Argentina
| |
Collapse
|
4
|
Sethi G, Grover V, Gupta J, Jain A. Response to adjunctive antibiotic therapy along with nonsurgical periodontal therapy in the treatment of peri-implantitis and chronic periodontitis patients: An exploratory review. J Indian Soc Periodontol 2024; 28:393-406. [PMID: 40018716 PMCID: PMC11864340 DOI: 10.4103/jisp.jisp_26_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 12/15/2024] [Accepted: 12/20/2024] [Indexed: 03/01/2025] Open
Abstract
Objectives This review was conducted to assess and compare whether there is a difference in response to adjunctive systemic and locally delivered antibiotics along with nonsurgical periodontal therapy (NSPT) in the treatment of peri-implantitis (PI) and chronic periodontitis (CP). Materials and Methods A systematic search of literature on the predefined criteria was conducted using PubMed, Embase, and Scopus. Probing pocket depth, bleeding on probing, clinical attachment level, and microbial load reduction were selected as primary outcomes, whereas plaque index and gingival index were evaluated as secondary outcomes. Standard Cochrane risk-of-bias tools were used for the quality assessment of the included studies, and a qualitative data synthesis was conducted owing to the observed heterogeneity of the extracted data. Results Adjunctive systemic and local antibiotics with NSPT resulted in additional beneficial effects in cases of both CP and PI, with greater improvement observed in cases of CP as compared to PI. Even for treatment of PI, among local antibiotics, minocycline was the only antibiotic with some significant adjunctive benefits, when used with NSPT as documented. Conclusion Within the limitations of the review, it is concluded that the adjunctive use of antibiotics with NSPT offers a beneficial effect in the management of both CP and PI; however, there is insufficient direct evidence regarding the comparative efficacy of the adjunctive antibiotic therapy along with NSPT for the treatment of PI and CP.
Collapse
Affiliation(s)
- Geetanshu Sethi
- Department of Periodontics, Maharishi Markandeshwar College of Dental Sciences and Research, Ambala, Haryana, India
| | - Vishakha Grover
- Department of Periodontics, Dr. Harvansh Singh Judge Institute of Dental Sciences and Hospital, Panjab University, Chandigarh, India
| | - Jyoti Gupta
- Department of Periodontics, Dr. Harvansh Singh Judge Institute of Dental Sciences and Hospital, Panjab University, Chandigarh, India
| | - Ashish Jain
- Department of Periodontics, Dr. Harvansh Singh Judge Institute of Dental Sciences and Hospital, Panjab University, Chandigarh, India
| |
Collapse
|
5
|
Li Y, Li X, Guo D, Meng L, Feng X, Zhang Y, Pan S. Immune dysregulation and macrophage polarization in peri-implantitis. Front Bioeng Biotechnol 2024; 12:1291880. [PMID: 38347915 PMCID: PMC10859439 DOI: 10.3389/fbioe.2024.1291880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Accepted: 01/09/2024] [Indexed: 02/15/2024] Open
Abstract
The term "peri-implantitis" (peri-implantitis) refers to an inflammatory lesion of the mucosa surrounding an endosseous implant and a progressive loss of the peri-implant bone that supports the implant. Recently, it has been suggested that the increased sensitivity of implants to infection and the quick elimination of supporting tissue after infection may be caused by a dysregulated peri-implant mucosal immune response. Macrophages are polarized in response to environmental signals and play multiple roles in peri-implantitis. In peri-implantitis lesion samples, recent investigations have discovered a considerable increase in M1 type macrophages, with M1 type macrophages contributing to the pro-inflammatory response brought on by bacteria, whereas M2 type macrophages contribute to inflammation remission and tissue repair. In an effort to better understand the pathogenesis of peri-implantitis and suggest potential immunomodulatory treatments for peri-implantitis in the direction of macrophage polarization patterns, this review summarizes the research findings related to macrophage polarization in peri-implantitis and compares them with periodontitis.
Collapse
Affiliation(s)
- Yue Li
- Department of Prosthodontics, Peking University School and Hospital of Stomatology and National Center for Stomatology and National Clinical Research Center for Oral Diseases and National Engineering Research Center of Oral Biomaterials and Digital Medical Devices and Beijing Key Laboratory of Digital Stomatology and Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health and NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Xue Li
- Stem Cell and Regenerative Medicine Lab, Beijing Institute of Radiation Medicine, Beijing, China
| | - Danni Guo
- Department of Prosthodontics, Peking University School and Hospital of Stomatology and National Center for Stomatology and National Clinical Research Center for Oral Diseases and National Engineering Research Center of Oral Biomaterials and Digital Medical Devices and Beijing Key Laboratory of Digital Stomatology and Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health and NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Lingwei Meng
- Department of Prosthodontics, Peking University School and Hospital of Stomatology and National Center for Stomatology and National Clinical Research Center for Oral Diseases and National Engineering Research Center of Oral Biomaterials and Digital Medical Devices and Beijing Key Laboratory of Digital Stomatology and Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health and NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Xianghui Feng
- Department of Periodontology, Peking University School and Hospital of Stomatology and National Center for Stomatology and National Clinical Research Center for Oral Diseases and National Engineering Research Center of Oral Biomaterials and Digital Medical Devices and Beijing Key Laboratory of Digital Stomatology and Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health and NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Yi Zhang
- Stem Cell and Regenerative Medicine Lab, Beijing Institute of Radiation Medicine, Beijing, China
| | - Shaoxia Pan
- Department of Prosthodontics, Peking University School and Hospital of Stomatology and National Center for Stomatology and National Clinical Research Center for Oral Diseases and National Engineering Research Center of Oral Biomaterials and Digital Medical Devices and Beijing Key Laboratory of Digital Stomatology and Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health and NMPA Key Laboratory for Dental Materials, Beijing, China
| |
Collapse
|
6
|
Cionca N, Meyer J, Michalet S, Varesio E, Hashim D. Quantification of titanium and zirconium elements in oral mucosa around healthy dental implants: a case-control pilot study. Clin Oral Investig 2023; 27:4715-4726. [PMID: 37270723 PMCID: PMC10415439 DOI: 10.1007/s00784-023-05099-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 05/29/2023] [Indexed: 06/05/2023]
Abstract
OBJECTIVES Metallic particles are detected in different sites of the oral cavity, mainly in patients with peri-implantitis lesions. The aim of this pilot study was to analyze the levels of titanium and zirconium elements in the oral mucosa around healthy implants and to investigate the impact of titanium exogenous contamination on the measurements. MATERIALS AND METHODS Forty-one participants were included in this three-phase study. Two groups of subjects were defined according to presence of titanium or zirconia implants (n: 20) or without any implants nor metallic restorations (n:21). Thirteen patients (n: 5 with zirconia implant; n: 3 with titanium implants; n: 5 control group) took part to the first part designed to optimize and validate the method of detecting titanium (Ti) and zirconium (Zr) elements in the oral mucosa and gingival tissues by the Inductively Coupled Plasma Mass Spectrometry (ICPMS). The second phase compared the levels of Ti and Zr concentrations in patients with implants (n: 12) and without implants (n: 6) who were controlled for their intake of titanium dioxide (TiO2). The last step included ten control subjects without any metallic devices to measure the concentration of Ti and Zr before and after having candies containing TiO2. RESULTS In the first phase, concentrations of Ti and Zr were below the limit of detection (LOD) in most cases, 0.18 μg/L and 0.07 μg/L respectively. In the titanium group, two out of three subjects displayed concentrations above the LOD, 0.21 μg/L and 0.66 μg/L. Zr element was only found in patients with zirconia implants. After controlling the intake of TiO2, all concentrations of Ti and Zr were below the limit of quantification (LOQ). Moreover, in patients with no implants, the Ti concentration in gingiva cells was superior for 75% of the samples after having a TiO2 diet. CONCLUSIONS Zirconium was only found in patients with zirconia implants, whereas titanium was detected in all groups even in subjects with no titanium implants. Zirconium and titanium elements were not detected in patients who were controlled for their intake of food and their use of toothpaste irrespective of the presence of implants or not. For 70% of the patients, the titanium detection was directly influenced by the intake of TiO2 contained candies. CLINICAL RELEVANCE When analyzing titanium particles, it is necessary to pay attention to the risk of contamination bias brought by external products. When this parameter was controlled, no titanium particles were detected around clinically healthy implants.
Collapse
Affiliation(s)
- Norbert Cionca
- Division of Regenerative Dental Medicine and Periodontology, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Julien Meyer
- Mass Spectrometry Core Facility (MZ 2.0), Faculty of Sciences, University of Geneva, Geneva, Switzerland
| | - Sophie Michalet
- Mass Spectrometry Core Facility (MZ 2.0), Faculty of Sciences, University of Geneva, Geneva, Switzerland
| | - Emmanuel Varesio
- Mass Spectrometry Core Facility (MZ 2.0), Faculty of Sciences, University of Geneva, Geneva, Switzerland
| | - Dena Hashim
- Division of Regenerative Dental Medicine and Periodontology, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
7
|
AjitSankardas P, Stein SH, Tipton D, Abhyankar V, Morrow BR. Impact of Metal Particles Released during Ultrasonic Scaling of Titanium Surfaces on Human Gingival Fibroblasts. J Long Term Eff Med Implants 2022; 33:9-22. [PMID: 36382700 DOI: 10.1615/jlongtermeffmedimplants.2022043080] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
PURPOSE Metal particles found in tissues around dental implants have been proposed to play a pathogenic role in peri-implantitis. Ultrasonic scaling has been suggested as a mechanism by which these particles can be inadvertently released into surrounding tissues. Furthermore, risk factors like diabetes can result in exacerbation of this inflammatory condition. The current study aimed to analyze metal particles released from titanium surfaces during ultrasonic scaling and their impact on pro-inflammatory cytokine production by human gingival fibroblasts. METHODS Metal particles generated from ultrasonic scaling of titanium discs using two different tips (metal and poly-etheretherketone tips) were characterized using scanning electron microscopy and elemental analysis. Endotoxin levels and Human gingival fibroblast viability, in the presence commercial and ultrasonically generated particles were determined. Fibroblasts, cultured in high or low glucose growth medium, were incubated with commercial titanium particles or ultrasonically generated particles in the presence or absence of interluekin-1β. Interleukin 6 and interleukin 8 production were then quantified using Enzyme linked immunosorbent assay. RESULTS Analysis of particles after scaling of titanium discs showed significant levels of titanium particles. Commercial titanium particles and generated particles had no effect of fibroblast viability. Endotoxin levels of all particles were too low to stimulate HGF cells. IL-1β significantly stimulated IL-6 and IL-8 production. However, commercial, and generated particles generally had no significant effect on IL- 6 and IL-8 production. CONCLUSION Our study concluded that particles generated during ultrasonic scaling had no significant effect on viability of HGF cells and cytokine production.
Collapse
Affiliation(s)
- Pooja AjitSankardas
- Department of Periodontology, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| | - Sidney H Stein
- Department of Periodontology, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| | - David Tipton
- Department of Bioscience Research, University of Tennessee Health Science Center, College of Dentistry, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| | - Vrushali Abhyankar
- Department of Periodontology, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| | - Brian R Morrow
- Department of Bioscience Research, University of Tennessee Health Science Center, College of Dentistry, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| |
Collapse
|
8
|
Gaur S, Agnihotri R, Albin S. Bio-Tribocorrosion of Titanium Dental Implants and Its Toxicological Implications: A Scoping Review. ScientificWorldJournal 2022; 2022:4498613. [PMID: 36312451 PMCID: PMC9616655 DOI: 10.1155/2022/4498613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 09/30/2022] [Indexed: 11/18/2022] Open
Abstract
Bio-tribocorrosion is a phenomenon that combines the essentials of tribology (friction, wear, and lubrication) and corrosion with microbiological processes. Lately, it has gained attention in implant dentistry because dental implants are exposed to wear, friction, and biofilm formation in the corrosive oral environment. They may degrade upon exposure to various microbial, biochemical, and electrochemical factors in the oral cavity. The mechanical movement of the implant components produces friction and wear that facilitates the release of metal ions, promoting adverse oro-systemic reactions. This review describes the bio-tribocorrosion of the titanium (Ti) dental implants in the oral cavity and its toxicological implications. The original research related to the bio-tribo or tribocorrosion of the dental implants was searched in electronic databases like Medline (Pubmed), Embase, Scopus, and Web of Science. About 34 studies included in the review showed that factors like the type of Ti, oral biofilm, acidic pH, fluorides, and micromovements during mastication promote bio-tribocorrosion of the Ti dental implants. Among the various grades of Ti, grade V, i.e., Ti6Al4V alloy, is most susceptible to tribocorrosion. Oral pathogens like Streptococcus mutans and Porphyromonas gingivalis produce acids and lipopolysaccharides (LPS) that cause pitting corrosion and degrade the TiO2. The low pH and high fluoride concentration in saliva hinder passive film formation and promote metal corrosion. The released metal ions promote inflammatory reactions and bone destruction in the surrounding tissues resulting in peri-implantitis, allergies, and hyper-sensitivity reactions. However, further validation of the role of bio-tribocorrosion on the durability of the Ti dental implants and Ti toxicity is warranted through clinical trials.
Collapse
Affiliation(s)
- Sumit Gaur
- Department of Pedodontics and Preventive Dentistry, Manipal College of Dental Sciences, Manipal, India
- Manipal Academy of Higher Education (MAHE), Manipal 576104, Karnataka, India
| | - Rupali Agnihotri
- Manipal Academy of Higher Education (MAHE), Manipal 576104, Karnataka, India
- Department of Periodontology, Manipal College of Dental Sciences, Manipal, India
| | - Sacharia Albin
- Engineering Department, Norfolk State University, Norfolk, VA 23504, USA
| |
Collapse
|
9
|
Lind KH, Ulvik IM, Berg E, Leknes KN. Reversible, non‐plaque‐induced marginal bone loss around an osseointegrated implant: A case report. Clin Case Rep 2022; 10:e05946. [PMID: 35685828 PMCID: PMC9172590 DOI: 10.1002/ccr3.5946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 05/18/2022] [Accepted: 05/24/2022] [Indexed: 11/29/2022] Open
Abstract
This case report documents a non‐plaque‐induced marginal bone loss around an osseointegrated implant. The loss of osseointegration, most likely caused by overload and/or suboptimal distribution of occlusal loading, may be reversed when the loading is reduced by optimally transmitting stress forces to the implant‐to‐bone interface and surrounding bone. Limited crestal bone width and a history of ridge augmentation may make peri‐implant supporting bone vulnerable to occlusal overload. In such cases, the prosthetic restoration should be planned with particular focus on reducing and optimizing the occlusal load.
Collapse
Affiliation(s)
- Kristian H. Lind
- Department of Clinical Dentistry Faculty of Medicine University of Bergen Bergen Norway
| | - Ingvild M. Ulvik
- Department of Clinical Dentistry Faculty of Medicine University of Bergen Bergen Norway
| | - Einar Berg
- Department of Clinical Dentistry – Prosthodontics Faculty of Medicine University of Bergen Bergen Norway
| | - Knut N. Leknes
- Department of Clinical Dentistry – Periodontics Faculty of Medicine University of Bergen Bergen Norway
| |
Collapse
|
10
|
Li L, Sun W, Yu J, Lei W, Zeng H, Shi B. Effects of titanium dioxide microparticles and nanoparticles on cytoskeletal organization, cell adhesion, migration, and proliferation in human gingival fibroblasts in the presence of lipopolysaccharide. J Periodontal Res 2022; 57:644-659. [PMID: 35438207 DOI: 10.1111/jre.12993] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 03/02/2022] [Accepted: 03/28/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND AND OBJECTIVE Titanium wear particles may participate in the etiology of peri-implantitis. However, the influence of titanium wear particles on biological behavior of human gingival fibroblasts (HGFs) in the presence of LPS is still not clear. The present study demonstrated the effects of titanium dioxide micro- and nanoparticles (TiO2 MPs and NPs) on HGF cell viability, cytoskeletal organization, adhesion, migration, and proliferation in vitro, and LPS was used to mimic the in vivo condition. METHODS Primary HGFs were treated with TiO2 MPs (primary particle size <5 μm, 0.1 mg/ml) and NPs (primary particle size <100 nm, 0.1 mg/ml) with or without 1 μg/ml LPS. The effects of TiO2 MPs and NPs on HGFs cell viability was measured by CCK-8 assay. The proliferation of HGF was detected by Ki67 nuclear staining. The confocal laser scanning microscope (CLSM) was used to detect the internalization of TiO2 MPs and NPs in HGFs as well as the arrangement of F-actin, vinculin, and vimentin organization. Wound healing assay and transwell assay were performed to measure the migration of HGFs induced by TiO2 MPs and NPs. Cell adhesion was measured using fibronectin-coated plates. The relative mRNA and protein expression of adhesion relative protein such as focal adhesion kinase (FAK), fibronectin (FN), and type I collagen (COL1) were measured using quantitative RT-PCR and western blot analysis. One-way analysis of variance (ANOVA) and Student's t-test were used to analyze the statistical significance, and p < .05 was considered statistically significant. RESULTS TiO2 NPs significantly inhibited HGF cell viability, proliferation, and migration compared with TiO2 MPs group and control group. Compared with control group (2.64 ± 0.09), the mean absorbance of the cells in 1 mg/ml TiO2 MPs group and 0.25 mg/ml TiO2 NPs group were significantly decreased to 1.93 ± 0.33 (p < .05) and 2.22 ± 0.18 (p < .01), respectively. The cytoskeleton disruption was found in TiO2 NPs group. The mRNA and protein expression were significantly downregulated by TiO2 NPs. Furthermore, both TiO2 NPs and MPs induced more adverse effects on HGFs in the presence of LPS. CONCLUSION Our results indicate that TiO2 NPs but not TiO2 MPs significantly disrupt the cytoskeletal organization and inhibited cell adhesion, migration, and proliferation of HGFs. However, in the presence of LPS, TiO2 MPs, and TiO2 NPs enhance these negative effects in HGFs. Titanium wear particles are probably involved in the initiation and progression of peri-implant diseases.
Collapse
Affiliation(s)
- Lei Li
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory for Oral Biomedical Ministry of Education, Wuhan, China.,School and Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Wei Sun
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory for Oral Biomedical Ministry of Education, Wuhan, China.,School and Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Jian Yu
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory for Oral Biomedical Ministry of Education, Wuhan, China.,School and Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Wenlong Lei
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory for Oral Biomedical Ministry of Education, Wuhan, China.,School and Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Hao Zeng
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory for Oral Biomedical Ministry of Education, Wuhan, China.,School and Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Bin Shi
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory for Oral Biomedical Ministry of Education, Wuhan, China.,School and Hospital of Stomatology, Wuhan University, Wuhan, China
| |
Collapse
|
11
|
Particle release from dental implants immediately after placement – An ex vivo comparison of different implant systems. Dent Mater 2022; 38:1004-1014. [DOI: 10.1016/j.dental.2022.04.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 03/14/2022] [Accepted: 04/01/2022] [Indexed: 11/20/2022]
|
12
|
A Biocompatible Ultrananocrystalline Diamond (UNCD) Coating for a New Generation of Dental Implants. NANOMATERIALS 2022; 12:nano12050782. [PMID: 35269268 PMCID: PMC8911871 DOI: 10.3390/nano12050782] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/09/2022] [Accepted: 02/17/2022] [Indexed: 02/04/2023]
Abstract
Implant therapy using osseointegratable titanium (Ti) dental implants has revolutionized clinical dental practice and has shown a high rate of success. However, because a metallic implant is in contact with body tissues and fluids in vivo, ions/particles can be released into the biological milieu as a result of corrosion or biotribocorrosion. Ultrananocrystalline diamond (UNCD) coatings possess a synergistic combination of mechanical, tribological, and chemical properties, which makes UNCD highly biocompatible. In addition, because the UNCD coating is made of carbon (C), a component of human DNA, cells, and molecules, it is potentially a highly biocompatible coating for medical implant devices. The aim of the present research was to evaluate tissue response to UNCD-coated titanium micro-implants using a murine model designed to evaluate biocompatibility. Non-coated (n = 10) and UNCD-coated (n = 10) orthodontic Ti micro-implants were placed in the hematopoietic bone marrow of the tibia of male Wistar rats. The animals were euthanized 30 days post implantation. The tibiae were resected, and ground histologic sections were obtained and stained with toluidine blue. Histologically, both groups showed lamellar bone tissue in contact with the implants (osseointegration). No inflammatory or multinucleated giant cells were observed. Histomorphometric evaluation showed no statistically significant differences in the percentage of BIC between groups (C: 53.40 ± 13% vs. UNCD: 58.82 ± 9%, p > 0.05). UNCD showed good biocompatibility properties. Although the percentage of BIC (osseointegration) was similar in UNCD-coated and control Ti micro-implants, the documented tribological properties of UNCD make it a superior implant coating material. Given the current surge in the use of nano-coatings, nanofilms, and nanostructured surfaces to enhance the biocompatibility of biomedical implants, the results of the present study contribute valuable data for the manufacture of UNCD coatings as a new generation of superior dental implants.
Collapse
|
13
|
Effect of the Nature of the Particles Released from Bone Level Dental Implants: Physicochemical and Biological Characterization. COATINGS 2022. [DOI: 10.3390/coatings12020219] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The placement of bone–level dental implants can lead to the detachment of particles in the surrounding tissues due to friction with the cortical bone. In this study, 60 bone–level dental implants were placed with the same design: 30 made of commercially pure grade 4 titanium and 30 made of Ti6Al4V alloy. These implants were placed in cow ribs following the company’s placement protocols. Particles detached from the dental implants were isolated and their size and specific surface area were characterized. The irregular morphology was observed by scanning electron microscopy. Ion release to the medium was determined at different immersion times in physiological medium. Cytocompatibility studies were performed with fibroblastic and osteoblastic cells. Gene expression and cytokine release were analysed to determine the action of inflammatory cells. Particle sizes of around 15 μM were obtained in both cases. The Ti6Al4V alloy particles showed significant levels of vanadium ion release and the cytocompatibility of these particles is lower than that of commercially pure titanium. Ti6Al4V alloy presents higher levels of inflammation markers (TNFα and Il–1β) compared to that of only titanium. Therefore, there is a trend that with the alloy there is a greater toxicity and a greater pro-inflammatory response.
Collapse
|
14
|
Domingo MG, Kurtz M, Maglione G, Martin M, Brites F, Tasat DR, Olmedo DG. Systemic effect of
TiO
2
micro‐ and nanoparticles after acute exposure in a murine model. J Biomed Mater Res B Appl Biomater 2022; 110:1563-1572. [DOI: 10.1002/jbm.b.35017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 12/02/2021] [Accepted: 01/19/2022] [Indexed: 11/07/2022]
Affiliation(s)
- Mariela Gisele Domingo
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica Buenos Aires Argentina
- Becario de Investigación de la Universidad de Buenos Aires Buenos Aires Argentina
| | - Melisa Kurtz
- CONICET Buenos Aires Argentina
- Universidad Nacional de San Martín, Escuela de Ciencia y Tecnología Buenos Aires Argentina
- CONICET ‐ Universidad Nacional de San Martín, Instituto de Tecnologías Emergentes y Ciencias Aplicadas (ITECA) San Martín, Buenos Aires Argentina
| | - Guillermo Maglione
- Universidad Nacional de San Martín, Escuela de Ciencia y Tecnología Buenos Aires Argentina
- CONICET ‐ Universidad Nacional de San Martín, Instituto de Tecnologías Emergentes y Ciencias Aplicadas (ITECA) San Martín, Buenos Aires Argentina
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Histología y Embriología Buenos Aires Argentina
| | | | - Fernando Brites
- CONICET Buenos Aires Argentina
- Universidad de Buenos Aires, Facultad de Farmacia y Bioquímica, Departamento de Bioquímica Clínica, Laboratorio de Lípidos y Lipoproteínas Buenos Aires Argentina
| | - Deborah Ruth Tasat
- Universidad Nacional de San Martín, Escuela de Ciencia y Tecnología Buenos Aires Argentina
- CONICET ‐ Universidad Nacional de San Martín, Instituto de Tecnologías Emergentes y Ciencias Aplicadas (ITECA) San Martín, Buenos Aires Argentina
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Histología y Embriología Buenos Aires Argentina
| | - Daniel Gustavo Olmedo
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica Buenos Aires Argentina
- CONICET Buenos Aires Argentina
| |
Collapse
|
15
|
Wu X, Cai C, Gil J, Jantz E, Al Sakka Y, Padial-Molina M, Suárez-López del Amo F. Characteristics of Particles and Debris Released after Implantoplasty: A Comparative Study. MATERIALS 2022; 15:ma15020602. [PMID: 35057319 PMCID: PMC8779414 DOI: 10.3390/ma15020602] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 01/05/2022] [Accepted: 01/11/2022] [Indexed: 02/08/2023]
Abstract
Titanium particles embedded on peri-implant tissues are associated with a variety of detrimental effects. Given that the characteristics of these detached fragments (size, concentration, etc.) dictate the potential cytotoxicity and biological repercussions exerted, it is of paramount importance to investigate the properties of these debris. This study compares the characteristics of particles released among different implant systems (Group A: Straumann, Group B: BioHorizons and Group C: Zimmer) during implantoplasty. A novel experimental system was utilized for measuring and collecting particles generated from implantoplasty. A scanning mobility particle sizer, aerodynamic particle sizer, nano micro-orifice uniform deposit impactor, and scanning electron microscope were used to collect and analyze the particles by size. The chemical composition of the particles was analyzed by highly sensitive microanalysis, microstructures by scanning electron microscope and the mechanical properties by nanoindentation equipment. Particles released by implantoplasty showed bimodal size distributions, with the majority of particles in the ultrafine size range (<100 nm) for all groups. Statistical analysis indicated a significant difference among all implant systems in terms of the particle number size distribution (p < 0.0001), with the highest concentration in Group B and lowest in Group C, in both fine and ultrafine modes. Significant differences among all groups (p < 0.0001) were also observed for the other two metrics, with the highest concentration of particle mass and surface area in Group B and lowest in Group C, in both fine and ultrafine modes. For coarse particles (>1 µm), no significant difference was detected among groups in terms of particle number or mass, but a significantly smaller surface area was found in Group A as compared to Group B (p = 0.02) and Group C (p = 0.005). The 1 first minute of procedures had a higher number concentration compared to the second and third minutes. SEM-EDS analysis showed different morphologies for various implant systems. These results can be explained by the differences in the chemical composition and microstructures of the different dental implants. Group B is softer than Groups A and C due to the laser treatment in the neck producing an increase of the grain size. The hardest implants were those of Group C due to the cold-strained titanium alloy, and consequently they displayed lower release than Groups A and B. Implantoplasty was associated with debris particle release, with the majority of particles at nanometric dimensions. BioHorizons implants released more particles compared to Straumann and Zimmer. Due to the widespread use of implantoplasty, it is of key importance to understand the characteristics of the generated debris. This is the first study to detect, quantify and analyze the debris/particles released from dental implants during implantoplasty including the full range of particle sizes, including both micro- and nano-scales.
Collapse
Affiliation(s)
- Xixi Wu
- Department of Periodontics, College of Dentistry, University of Oklahoma, Oklahoma City, OK 73117, USA; (X.W.); (E.J.)
| | - Changjie Cai
- Department of Occupational and Environmental Health, Hudson College of Public Health, University of Oklahoma, Oklahoma City, OK 73117, USA;
| | - Javier Gil
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, Josep Trueta s/n. Sant Cugat del Vallés, 08125 Barcelona, Spain
- Facultat de Odontologia, Universitat Internacional de Catalunya, Josep Trueta s/n. San Cugat del Vallés, 08125 Barcelona, Spain
- Correspondence: (J.G.); (F.S.-L.d.A.)
| | - Elizabeth Jantz
- Department of Periodontics, College of Dentistry, University of Oklahoma, Oklahoma City, OK 73117, USA; (X.W.); (E.J.)
| | | | - Miguel Padial-Molina
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain;
| | | |
Collapse
|
16
|
Analysis of Torque Maintenance and Fracture Resistance after Fatigue in Retention Screws Made of Different Metals for Screw-Retained Implant-Borne Prosthesis Joints. Int J Dent 2021; 2021:9693239. [PMID: 34840575 PMCID: PMC8616656 DOI: 10.1155/2021/9693239] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Accepted: 10/18/2021] [Indexed: 11/24/2022] Open
Abstract
Purpose The aim was to evaluate the effect of different metallic alloys used in the manufacture of retention screws for universal cast to long abutment (UCLA) abutments for external hexagon (HE) and Morse taper (MT) connection implants, as well as of mechanical cycling on torque maintenance and fracture resistance through electromechanical fatigue testing by mastication followed by compression testing. Methods Sixty implants were used, 30 MT and 30 HE, with their respective titanium UCLA abutments and retention screws of 5 different materials (n = 6): Ti cp grade 2, Ti cp grade 4, Ti cp grade 4 hard, Ti grade 5—Ti6Al4V and surgical steel (DSP® Biomedical). The assemblies were positioned in an electromechanical masticatory fatigue testing machine. The fracture strength test was performed by compression testing in a universal testing machine EMICDL-200. Results The cycled screws and new screws of each alloy group for each connection type were evaluated, obtaining the maximum force (FM), in order to verify the effect of mechanical cycling. The data were tabulated and submitted to appropriate statistical analysis (α = 0.05). Conclusion It was concluded that for the MT, the alloy with the best performance was steel, both in the maintenance of torque and in the compression test, and cycling negatively influenced the maintenance of preload for this connection. The alloy material did not influence torque maintenance for HE. The new screws that were subjected to EMIC showed higher strength. The alloy with the lowest strength was Ti grade 2.
Collapse
|
17
|
Shafizadeh M, Amid R, Mahmoum M, Kadkhodazadeh M. Histopathological characterization of peri-implant diseases: A systematic review and meta-analysis. Arch Oral Biol 2021; 132:105288. [PMID: 34688133 DOI: 10.1016/j.archoralbio.2021.105288] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 10/07/2021] [Accepted: 10/11/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To conduct a systematic review of the inflammatory elements in peri-implantitis (PI) and peri-implant mucositis (PM) in comparison with healthy peri-implant tissues (HI) and periodontal disease. DESIGN The PubMed, Embase, Web of Science, and Scopus databases were searched up to December 2020. English articles that evaluated human soft tissue biopsies of PI or PM were included. Values reported for the surface area of the infiltrated connective tissue (ICT) were pooled using the random-effect model meta-analysis to estimate the mean (95% CI). RESULTS A total of 33 articles were included. Of 30 studies on PI, the majority evidenced significantly increased vascularization and inflammatory cell counts dominated by plasma cells in PI compared with HI. Studies that compared PI with chronic periodontitis primarily reported more severe inflammatory infiltrates in PI. This was confirmed by the meta-analysis results since the surface area of the ICT was significantly larger in PI (p < 0.001). Only seven studies analyzed the PM lesions and reported increased inflammatory infiltrates and vascularization in PM compared with HI. Based on the meta-analysis results, the surface area of the ICT was 3.00 [1.50, 4.51] mm 2 in PI and 0.23 [0.02, 0.44] mm 2 in PM lesions. Based on the available evidence, presence of foreign body particles considerably increased the inflammatory infiltrate; however, smoking did not have a significant effect. CONCLUSIONS There was controversy regarding the prevalence of various inflammatory cell types in peri-implant diseases; however, a considerably high ICT surface area in PI indicates the aggressive nature of the disease.
Collapse
Affiliation(s)
- Marziyeh Shafizadeh
- Periodontics Department, School of Dentistry, Shahid Beheshti University of Medical Sciences, Evin, Tehran, Iran; Dental Research Centre, Shahid Beheshti University of Medical Sciences, Evin, Tehran, Iran
| | - Reza Amid
- Periodontics Department, School of Dentistry, Shahid Beheshti University of Medical Sciences, Evin, Tehran, Iran
| | - Masoumeh Mahmoum
- Periodontics Department, School of Dentistry, Shahid Beheshti University of Medical Sciences, Evin, Tehran, Iran
| | - Mahdi Kadkhodazadeh
- Periodontics Department, School of Dentistry, Shahid Beheshti University of Medical Sciences, Evin, Tehran, Iran; Dental Research Centre, Shahid Beheshti University of Medical Sciences, Evin, Tehran, Iran.
| |
Collapse
|
18
|
Effect of Titanium and Zirconium Oxide Microparticles on Pro-Inflammatory Response in Human Macrophages under Induced Sterile Inflammation: An In Vitro Study. MATERIALS 2021; 14:ma14154166. [PMID: 34361359 PMCID: PMC8347735 DOI: 10.3390/ma14154166] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 06/29/2021] [Accepted: 07/25/2021] [Indexed: 11/16/2022]
Abstract
The wear-debris particles released by shearing forces during dental implant insertion may contribute to inflammatory reactions or osteolysis associated with peri-implantitis by stimulating inflammasome-activation. The study aim was to examine cytotoxic and pro-inflammatory effects of titanium (TiO2) and zirconia (ZrO2) particles in macrophages regarding their nature/particle concentration over time under sterile lipopolysaccharide (LPS) inflammation. Macrophages were exposed to TiO2 and ZrO2 particles (≤5 µm) in cell culture. Dental glass was used as inert control and LPS (1 μg/mL) was used to promote sterile inflammation. Cytotoxicity was determined using MTT assays and cytokine expression of TNF-α, IL-1β and IL-6 was evaluated by qRT-PCR. Data were analyzed using Student's t-test and ANOVA (p ≤ 0.05). Cytotoxicity was significantly increased when exposed to higher concentrations of glass, TiO2 and ZrO2 (≥107 particles/mL) compared to controls (p ≤ 0.05). Macrophages challenged with TiO2 particles expressed up to ≈3.5-fold higher upregulation than ZrO2 from 12 to 48 h. However, when exposed to LPS, TiO2 and ZrO2 particle-induced pro-inflammatory gene expression was further enhanced (p ≤ 0.05). Our data suggest that ZrO2 particles produce less toxicity/inflammatory cytokine production than TiO2. The present study shows that the biological reactivity of TiO2 and ZrO2 depends on the type and concentration of particles in a time-dependent manner.
Collapse
|
19
|
Effect of macrogeometry and bone type on insertion torque, primary stability, surface topography damage and titanium release of dental implants during surgical insertion into artificial bone. J Mech Behav Biomed Mater 2021; 119:104515. [PMID: 33932754 DOI: 10.1016/j.jmbbm.2021.104515] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 03/12/2021] [Accepted: 04/05/2021] [Indexed: 11/20/2022]
Abstract
This study investigated the influence of implant macrogeometry and bone type on insertion torque (IT), primary stability (ISQ), surface topography damage, and the amount of titanium (Ti) released during insertion. Forty implants with different macrogeometries (Facility - Cylindrical with spiral-shaped threads; Alvim - Tapered with buttress-shaped threads) were inserted into artificial bone types I-II and III-IV. Surface morphology was evaluated by Scanning Electron Microscope (SEM) and roughness parameters with Laser Scanning Confocal Microscopy (LSCM) before and after insertion (AI). Implant macrogeometry was characterized by LSCM. The chemical composition of bone beds was determined by SEM associated with Energy Dispersive X-Ray Spectroscopy. The amount of Ti released was analyzed with Energy Dispersive X-Ray Fluorescence. Alvim had greater IT and ISQ than Facility. Bone types I-II require higher IT of implants. Alvim also had greater internal threads angle, higher initial roughness, and significant reduction of roughness AI, compared to Facility. The functional surface height reduced AI, especially in flank and valley of threads. Height of surface roughness of Alvim and Facility implants was similar AI. Implants surface morphology changes and metallic particles on bone beds were observed after implant insertion, mainly into bone types III-IV. Implants inserted into bone types I-II showed less surface damage. Alvim implants released more Ti (37.52 ± 25.03 ppm) than Facility (11.66 ± 28.55 ppm) on bone types III-IV. The implant macrogeometry and bone types affect IT, ISQ, surface damage, and Ti amount released during insertion. Alvim implants were more wear susceptible, releasing higher Ti concentration during insertion into bone types III-IV.
Collapse
|
20
|
Kotsakis GA, Olmedo DG. Peri-implantitis is not periodontitis: Scientific discoveries shed light on microbiome-biomaterial interactions that may determine disease phenotype. Periodontol 2000 2021; 86:231-240. [PMID: 33690947 DOI: 10.1111/prd.12372] [Citation(s) in RCA: 111] [Impact Index Per Article: 27.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Peri-implantitis is an immune-mediated biological complication that is attributed to bacterial biofilms on the implant surface. As both periodontitis and peri-implantitis have similar inflammatory phenotypes when assessed cross-sectionally, treatment protocols for peri-implantitis were modeled according to those used for periodontitis. However, lack of efficacy of antimicrobial treatments targeting periodontal pathogens coupled with recent discoveries from open-ended microbial investigation studies create a heightened need to revisit the pathogenesis of peri-implantitis compared with that of periodontitis. The tale of biofilm formation on intraoral solid surfaces begins with pellicle formation, which supports initial bacterial adhesion. The differences between implant- and tooth-bound biofilms appear as early as bacterial adhesion commences. The electrostatic forces and ionic bonding that drive initial bacterial adhesion are fundamentally different in the presence of titanium dioxide or other implant alloys vs mineralized organic hydroxyapatite, respectively. Moreover, the interaction between metal surfaces and the oral environment leads to the release of implant degradation products into the peri-implant sulcus, which exposes the microbiota to increased environmental stress and may alter immune responses to bacteria. Clinically, biofilms found in peri-implantitis are resistant to beta-lactam antibiotics, which are effective against periodontal communities even as monotherapies and demonstrate a composition different from that of biofilms found in periodontitis; these facts strongly suggest that a new model of peri-implant infection is required.
Collapse
Affiliation(s)
- Georgios A Kotsakis
- Department of Periodontics, University of Texas Health San Antonio, San Antonio, Texas, USA
| | - Daniel G Olmedo
- Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Anatomía Patológica, Buenos Aires, Argentina & CONICET, Buenos Aires, Argentina
| |
Collapse
|
21
|
Paparella ML, Domingo MG, Puia SA, Jacobi-Gresser E, Olmedo DG. Titanium dental implant-related pathologies: A retrospective histopathological study. Oral Dis 2021; 28:503-512. [PMID: 33544935 DOI: 10.1111/odi.13794] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 01/28/2021] [Accepted: 01/31/2021] [Indexed: 12/17/2022]
Abstract
OBJECTIVES To perform a retrospective, descriptive, histopathological study of peri-implant tissue pathologies associated with titanium dental implants (TDI), and to evaluate the presence of metallic particles in samples from a single diagnostic center. METHODS Sixty-eight cases of TDI-associated lesions were retrieved from the Surgical Pathology Laboratory archives, School of Dentistry, University of Buenos Aires (UBA) (1990-2018). The study included re-examining the histopathological features of the biopsy samples, analyzing the inflammatory infiltrate, and examining the samples to detect metallic particles whose chemical composition was determined spectrophotometrically (EDS). Available clinical and radiographic data were also reviewed. RESULTS The retrieved cases ranged from lesions of inflammatory origin to neoplastic lesions. Metallic particles were observed in 36 cases (52.9%), all of which showed inflammation. Particle length ranged from 2 to 85µm. EDS analysis of the particles/deposits observed in the tissues showed the presence of aluminum, titanium, iron, and nickel, among other elements. CONCLUSIONS A significant number of TDI-associated lesions, including cases not reported to date and diagnosed at a single diagnostic center, are shown here. Cases showing particles exhibited an inflammatory response, irrespective of the histopathological diagnosis. The role of metallic particles in the development of TDI-associated lesion is yet to be established.
Collapse
Affiliation(s)
- María Luisa Paparella
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica, Buenos Aires, Argentina
| | - Mariela Gisele Domingo
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica, Buenos Aires, Argentina.,Research Fellow of the University of Buenos Aires, Buenos Aires, Argentina
| | - Sebastián Ariel Puia
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Cirugía I, Buenos Aires, Argentina
| | | | - Daniel Gustavo Olmedo
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica, Buenos Aires, Argentina.,National Council of Scientific and Technical Research (CONICET), Buenos Aires, Argentina
| |
Collapse
|
22
|
Immunological Aspects of Dental Implant Rejection. BIOMED RESEARCH INTERNATIONAL 2020; 2020:7279509. [PMID: 33376734 PMCID: PMC7744195 DOI: 10.1155/2020/7279509] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 10/29/2020] [Accepted: 11/24/2020] [Indexed: 12/12/2022]
Abstract
Nowadays, dental implants are a prominent therapeutic approach among dentists for replacing missing teeth. Failure in dental implants is a severe challenge recently. The factors which lead to dental implant failure are known. These factors can be categorized into different groups. In this article, we discussed the immunological aspects of implant failure as one of these groups. Cytokines and immune cells have extensive and various functions in peri-implantitis. The equilibrium between pro and anti-inflammatory cytokines and cells, which involve in this orchestra, has a crucial role in implant prognosis. In conclusion, immune cells, especially macrophages and dendritic cells, almost increased in the patients with implant failure. Also, proinflammatory cytokines were proposed as diagnostic factors according to their higher levels in dental implant rejection.
Collapse
|
23
|
Silva GAF, Faot F, da Silva WJ, Del Bel Cury AA. Does implant surface hydrophilicity influence the maintenance of surface integrity after insertion into low-density artificial bone? Dent Mater 2020; 37:e69-e84. [PMID: 33234316 DOI: 10.1016/j.dental.2020.10.024] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 08/05/2020] [Accepted: 10/24/2020] [Indexed: 01/07/2023]
Abstract
OBJECTIVE To evaluate the influence of hydrophilicity on the surface integrity of implants after insertion in low-density artificial bone and to determine the distribution of titanium (Ti) particles along the bone bed. METHODS Forty-eight dental implants with different designs (Titamax Ex, Facility, Alvim, and Drive) and surface treatments (Neoporos® and Aqua™) were inserted into artificial bone blocks with density compatible with bone type III-IV. Hydrophobic Neoporos® surfaces were obtained by sandblasting and acid etching while hydrophilic Aqua™ surfaces were obtained by sandblasting, acid etching, and storage in an isotonic 0.9% NaCl solution. The surface integrity was evaluated by Scanning Electron Microscope (SEM) and the surface roughness parameters (Sa, Sp, Ssk, Sdr, Spk, Sk, and Svk) and surface area were measured with Laser Scanning Confocal Microscopy before and after installation. Bone beds were inspected with Digital Microscopy and micro X-Ray Fluorescence (μ-XRF) to analyze the metallic element distribution along the bone bed. RESULTS Acqua™ implants had higher initial Sa and a pronounced reduction of Sa and Sp during insertion, compared to NeoPoros® implants. After insertion, Sa and Sp of Acqua™ and NeoPoros® implants equalized, differing only between designs of Acqua™ implants. Surface damage was observed after insertion, mainly in the apical region. Facility implants that are made of TiG5 released fewer debris particles, while the highest Ti intensity was detected in the cervical region of the Titamax Ex Acqua™ and Drive Acqua™ implants. SIGNIFICANCE Physicochemical modifications to achieve surface hydrophilicity created a rougher surface that was more susceptible to surface alterations, resulting in more Ti particle release into the bone bed during surgical insertion. The higher Ti intensities detected in the cervical region of bone beds may be related to peri-implantitis and marginal bone resorption.
Collapse
Affiliation(s)
| | - Fernanda Faot
- Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.
| | - Wander José da Silva
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Campinas, SP, Brazil.
| | - Altair Antoninha Del Bel Cury
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Campinas, SP, Brazil.
| |
Collapse
|
24
|
Comino-Garayoa R, Cortés-Bretón Brinkmann J, Peláez J, López-Suárez C, Martínez-González JM, Suárez MJ. Allergies to Titanium Dental Implants: What Do We Really Know about Them? A Scoping Review. BIOLOGY 2020; 9:E404. [PMID: 33217944 PMCID: PMC7698636 DOI: 10.3390/biology9110404] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 11/12/2020] [Accepted: 11/16/2020] [Indexed: 02/07/2023]
Abstract
The purpose of this scoping review was to describe the current state of knowledge and understanding of allergies to titanium dental implants. A scoping review was conducted following the Prisma Extension for Scoping Reviews checklist. An electronic search was performed in five databases complemented by manual and grey literature searches. Fifty-two relevant papers were included for final review. Titanium particles can be released from the surfaces of dental implants in a process called tribocorrosion, which may contribute to bone loss due to inflammatory reaction. Diverse mechanisms have been described that may trigger allergy to titanium, as well as the clinical signs that manifest as the allergy develops. Allergies to titanium are uncommon but represent a real possibility that should not be overlooked in patients requiring prosthodontic rehabilitation with dental implants. Allergy can trigger a range of symptoms. Patients who have already been diagnosed with allergies to other metals will be more predisposed to suffering an allergy to titanium. Further investigation is needed in order to measure the true scope of these allergies.
Collapse
Affiliation(s)
- Rubén Comino-Garayoa
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28001 Madrid, Spain; (R.C.-G.); (J.P.); (C.L.-S.); (M.J.S.)
| | - Jorge Cortés-Bretón Brinkmann
- Department of Dental Clinical Specialties, Faculty of Dentistry, Complutense University of Madrid, 28001 Madrid, Spain;
| | - Jesús Peláez
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28001 Madrid, Spain; (R.C.-G.); (J.P.); (C.L.-S.); (M.J.S.)
| | - Carlos López-Suárez
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28001 Madrid, Spain; (R.C.-G.); (J.P.); (C.L.-S.); (M.J.S.)
| | - Jose María Martínez-González
- Department of Dental Clinical Specialties, Faculty of Dentistry, Complutense University of Madrid, 28001 Madrid, Spain;
| | - María Jesús Suárez
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28001 Madrid, Spain; (R.C.-G.); (J.P.); (C.L.-S.); (M.J.S.)
| |
Collapse
|
25
|
Berryman Z, Bridger L, Hussaini HM, Rich AM, Atieh M, Tawse-Smith A. Titanium particles: An emerging risk factor for peri-implant bone loss. Saudi Dent J 2020; 32:283-292. [PMID: 32874068 PMCID: PMC7452065 DOI: 10.1016/j.sdentj.2019.09.008] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 09/19/2019] [Accepted: 09/25/2019] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE To investigate the presence of titanium particles in peri-implant tissues in cases diagnosed with peri-implantitis, and to identify immunological reactions that these particles may elicit. METHODS Ten peri-implant tissue biopsies of patients diagnosed clinically and radiographically with peri-implantitis were obtained from the archives of Oral Pathology Centre, University of Otago. The inclusion criteria involves: bleeding on probing, ≥6 mm probing depth and ≥3 mm radiographic bone loss around the dental implant. Peri-implant tissue samples were evaluated using scanning electron microscopy-energy dispersive x-ray spectroscopy (SEM-EDS) to identify of sites with/without titanium particles. Antibodies against human transforming growth factor beta 1 (TGF-β1), receptor activator of nuclear factor kappa-B ligand (RANKL), interleukin 33 (IL-33) and cluster of differentiation 68 (CD68) were used to stain the specimens. ImageJ software was used to standardise the sampling area, compare and characterise the inflammatory infiltrate in tissues with/without titanium particles. Inflammatory cytokines positivity was assessed using the immunoreactive scores (IRSs). RESULTS Light microscopy and SEM-EDS analysis identified titanium wear particles in 90% of the tissue samples, associated with a mixed chronic inflammatory infiltrate. Quantification analysis of RANKL revealed significantly higher IRS and intensity scores (p < 0.05) in areas containing titanium. High intensity, proportion and IRSs of TGF-β1 and IL-33 were observed in areas with titanium. CD68 had higher IRSs in the absence of titanium particles. CONCLUSIONS Significant overexpression of the cytokine RANKL was observed, with a trend for over-expression of IL-33 and TGF-B1 in areas with titanium. Further studies with large sample size and appropriate control group for quantification analysis is needed to confirm the role of titanium particles in initiating bone loss.
Collapse
Affiliation(s)
- Zoë Berryman
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Laura Bridger
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Haizal Mohd Hussaini
- Department of Oral Diagnostic and Surgical Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Alison M. Rich
- Department of Oral Diagnostic and Surgical Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Momen Atieh
- Mohammed Bin Rashid University of Medicine and Health Sciences, Hamdan Bin Mohammed College of Dental Medicine, Dubai Healthcare City, Dubai, United Arab Emirates
| | - Andrew Tawse-Smith
- Department of Oral Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| |
Collapse
|
26
|
Romanos GE, Delgado-Ruiz R, Sculean A. Concepts for prevention of complications in implant therapy. Periodontol 2000 2019; 81:7-17. [PMID: 31407435 DOI: 10.1111/prd.12278] [Citation(s) in RCA: 81] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The use of dental implants is nowadays a well-accepted and highly predictable treatment modality for restoring the dentition and reestablishing the masticatory function of edentulous and partially edentulous patients. Despite the high predictability and excellent long-term survival rates reported for implant therapy, complications may still occur and can jeopardize both short- and long-term success. The present paper provides an overview on the most important aspects related to the etiology, prevention, and management of complications associated with implant therapy. Data from the literature indicate that a number of factors, such as surgical trauma, implant diameter, type of implant-abutment connection, abutment disconnection and reconnection, presence of microgap, and implant malpositioning, can substantially influence the biologic processes of bone remodeling and biofilm formation, thus increasing the rate of short- and long-term hard- and soft-tissue complications. Other factors, such as excess cement at cement-retained prosthetic restorations, abutment mobility, and infections (e.g. peri-implant mucositis and peri-implantitis) caused by bacterial biofilm, are further causes for complications and failures. More recent evidence also indicates that besides the need for sufficient bone volume surrounding the implant, the presence of an adequate width and thickness of attached mucosa may improve biofilm control and limit crestal bone resorption. Furthermore, emerging evidence points also to the pivotal role of human factors as one of the most important causes of complications in implant dentistry. It can be concluded that clinicians need to consider all biologic and biomechanical factors affecting implant placement and survival, as well as undergo adequate training to improve their surgical skills to control and prevent implant complications. Careful patient selection and control of environmental and systemic factors, such as smoking, diabetes etc., coupled with an accurate surgical and prosthetic planning, enable a better prevention and control of infections.
Collapse
Affiliation(s)
- Georgios E Romanos
- Department of Periodontology, School of Dental Medicine, Stony Brook University, Stony Brook, New York, USA
| | - Rafael Delgado-Ruiz
- Department of Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, New York, USA
| | - Anton Sculean
- Department of Periodontology, University of Bern, Bern, Switzerland
| |
Collapse
|
27
|
Abstract
Osseointegration was originally defined as a direct structural and functional connection between ordered living bone and the surface of a load-carrying implant. It is now said that an implant is regarded as osseointegrated when there is no progressive relative movement between the implant and the bone with which it is in direct contact. Although the term osseointegration was initially used with reference to titanium metallic implants, the concept is currently applied to all biomaterials that have the ability to osseointegrate. Biomaterials are closely related to the mechanism of osseointegration; these materials are designed to be implanted or incorporated into the living system with the aims to substitute for, or regenerate, tissues and tissue functions. Objective evaluation of the properties of the different biomaterials and of the factors that influence bone repair in general, and at the bone tissue-implant interface, is essential to the clinical success of an implant. The Biomaterials Laboratory of the Oral Pathology Department of the School of Dentistry at the University of Buenos Aires is devoted to the study and research of the properties and biological effects of biomaterials for dental implants and bone substitutes. This paper summarizes the research work resulting from over 25 years' experience in this field. It includes studies conducted at our laboratory on the local and systemic factors affecting the peri-implant bone healing process, using experimental models developed by our research team. The results of our research on corrosion, focusing on dental implants, as well as our experience in the evaluation of failed dental implants and bone biopsies obtained following maxillary sinus floor augmentation with bone substitutes, are also reported. Research on biomaterials and their interaction with the biological system is a continuing challenge in biomedicine, which aims to achieve optimal biocompatibility and thus contribute to patient health.
Collapse
Affiliation(s)
- María B Guglielmotti
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina.,National Research Council (CONICET), Buenos Aires, Argentina
| | - Daniel G Olmedo
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina.,National Research Council (CONICET), Buenos Aires, Argentina
| | - Rómulo L Cabrini
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina.,Department of Radiobiology, National Atomic Energy Commission, Buenos Aires, Argentina
| |
Collapse
|
28
|
Al Otaibi A, Sherif ESM, Al-Rifaiy MQ, Zinelis S, Al Jabbari YS. Corrosion resistance of coupled sandblasted, large-grit, acid-etched (SLA) and anodized Ti implant surfaces in synthetic saliva. Clin Exp Dent Res 2019; 5:452-459. [PMID: 31687177 PMCID: PMC6820584 DOI: 10.1002/cre2.198] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 02/16/2019] [Accepted: 02/18/2019] [Indexed: 11/17/2022] Open
Abstract
Purpose The purpose of this study was to investigate the corrosion resistance of galvanically coupled SLA and anodized implant surfaces with a Co‐Cr alloy. Materials and Methods Three groups were included in this study. The first (SLA) was composed of SLA implants (Institut Straumann, Basel, Switzerland), the second (ANO) of NobelReplace® (Nobel Biocare, Göteborg, Sweden), and the third (MIX) of both implant systems combined. All groups were assembled with a single Co‐Cr superstructure. Electrochemical testing included open‐circuit potential, electrochemical impedance spectroscopy, cyclic potentiodynamic polarization, and chronoamperometric current‐time measurements. The quantitative results (EOCP, ECORR, ICORR, EPROT, RP, and ICA) were statistically analyzed by one‐way ANOVA and Tukey's post‐hoc multiple comparison test (α = 0.05) Results All the aforementioned parameters showed statistically significant differences apart from ECORR and EPROT. The evaluation of qualitative and quantitative results showed that although SLA had higher corrosion resistance compared with ANO, it had less resistance to pitting corrosion. This means that SLA showed increased resistance to uniform corrosion but less resistance if pitting corrosion was initiated. In all cases, MIX showed intermediate behavior. Conclusion The corrosion resistance of implant‐retained superstructures is dependent on the electrochemical properties of the implants involved, and thus different degrees of intraoral corrosion resistance among different implant systems are anticipated.
Collapse
Affiliation(s)
- Ala'a Al Otaibi
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - El-Sayed M Sherif
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Center of Excellence for Research in Engineering Materials (CEREM) King Saud University Riyadh Saudi Arabia.,Electrochemistry and Corrosion Laboratory, Department of Physical Chemistry National Research Centre (NRC) Cairo Egypt
| | - Mohammed Q Al-Rifaiy
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry National and Kapodistrian University of Athens Athens Greece.,Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - Youssef S Al Jabbari
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| |
Collapse
|
29
|
Effect of Titanium Particles on the Voltage-Gated Potassium Channel Currents in Trigeminal Root Ganglion Neurons. IMPLANT DENT 2019; 28:54-61. [PMID: 30507652 DOI: 10.1097/id.0000000000000848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
PURPOSE Titanium (Ti) is the key material used in dental implants because of its excellent biocompatibility. But wear and corrosion Ti particles had been widely reported to induce inflammation and promote bone absorption. However, little information is known about the damage of Ti particles on neurons. MATERIALS AND METHODS Trigeminal root ganglion (TRG) neurons were exposed to Ti particles (<5 μm). The electrophysiological properties of 2 main subtypes of voltage-gated potassium channels (VGPCs) (KA and KV) were examined by whole-cell patch-clamp techniques. RESULT With the presence of 0.25 mg/mL Ti particles, amplitudes of IK, A and IK, V were both obviously inhibited. For IK, A, the activation V1/2 shifted to the depolarizing direction with an increased k value, whereas the inactivation V1/2 showed obvious hyperdepolarizing shifts. For IK, V, 0.5 mg/mL Ti particles produced a depolarizing shift of activation V1/2 with a slower activation rate. No significant changes of its inactivation kinetics were found. CONCLUSION Titanium (Ti) particles might alter the electrophysiological properties of VGPCs on TRG neurons, which are likely to further influence the excitability of neurons.
Collapse
|
30
|
Daubert D, Pozhitkov A, Safioti L, Kotsakis G. Association of Global DNA Methylation to Titanium and Peri-Implantitis: A Case-Control Study. JDR Clin Trans Res 2019; 4:284-291. [DOI: 10.1177/2380084418822831] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Affiliation(s)
- D.M. Daubert
- Department of Periodontics, University of Washington, Seattle, WA, USA
| | - A.E. Pozhitkov
- Department of Restorative Dentistry, University of Washington, Seattle, WA, USA
| | - L.M. Safioti
- Department of Periodontics, University of Washington, Seattle, WA, USA
| | - G.A. Kotsakis
- Department of Periodontics, University of Washington, Seattle, WA, USA
| |
Collapse
|
31
|
Eger M, Hiram-Bab S, Liron T, Sterer N, Carmi Y, Kohavi D, Gabet Y. Mechanism and Prevention of Titanium Particle-Induced Inflammation and Osteolysis. Front Immunol 2018; 9:2963. [PMID: 30619321 PMCID: PMC6305459 DOI: 10.3389/fimmu.2018.02963] [Citation(s) in RCA: 89] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 12/03/2018] [Indexed: 12/24/2022] Open
Abstract
The worldwide number of dental implants and orthopedic prostheses is steadily increasing. Orthopedic implant loosening, in the absence of infection, is mostly attributable to the generation of wear debris. Dental peri-implantitis is characterized by a multifactorial etiology and is the main cause of implant failure. It consists of a peri-implant inflammatory lesion that often results in loss of supporting bone. Disease management includes cleaning the surrounding flora by hand instruments, ultrasonic tips, lasers, or chemical agents. We recently published a paper indicating that US scaling of titanium (Ti) implants releases particles that provoke an inflammatory response and osteolysis. Here we show that a strong inflammatory response occurs; however, very few of the titanium particles are phagocytosed by the macrophages. We then measured a dramatic Ti particle-induced stimulation of IL1β, IL6, and TNFα secretion by these macrophages using multiplex immunoassay. The particle-induced expression profile, examined by FACS, also indicated an M1 macrophage polarization. To assess how the secreted cytokines contributed to the paracrine exacerbation of the inflammatory response and to osteoclastogenesis, we treated macrophage/preosteoclast cultures with neutralizing antibodies against IL1β, IL6, or TNFα. We found that anti-TNFα antibodies attenuated the overall expression of both the inflammatory cytokines and osteoclastogenesis. On the other hand, anti-IL1β antibodies affected osteoclastogenesis but not the paracrine expression of inflammatory cytokines, whereas anti-IL6 antibodies did the opposite. We then tested these neutralizing antibodies in vivo using our mouse calvarial model of Ti particle-induced osteolysis and microCT analysis. Here, all neutralizing antibodies, administered by intraperitoneal injection, completely abrogated the particle-induced osteolysis. This suggests that blockage of paracrine inflammatory stimulation and osteoclastogenesis are similarly effective in preventing bone resorption induced by Ti particles. Blocking both the inflammation and osteoclastogenesis by anti-TNFα antibodies, incorporated locally into a slow-release membrane, also significantly prevented osteolysis. The osteolytic inflammatory response, fueled by ultrasonic scaling of Ti implants, results from an inflammatory positive feedback loop and osteoclastogenic stimulation. Our findings suggest that blocking IL1β, IL6, and/or TNFα systemically or locally around titanium implants is a promising therapeutic approach for the clinical management of peri-implant bone loss.
Collapse
Affiliation(s)
- Michal Eger
- Department of Anatomy and Anthropology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.,Department of Prosthodontics, Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Sahar Hiram-Bab
- Department of Anatomy and Anthropology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Tamar Liron
- Department of Anatomy and Anthropology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Nir Sterer
- Department of Prosthodontics, Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yaron Carmi
- Department of Pathology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - David Kohavi
- Department of Prosthodontics, Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yankel Gabet
- Department of Anatomy and Anthropology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
32
|
Mombelli A, Hashim D, Cionca N. What is the impact of titanium particles and biocorrosion on implant survival and complications? A critical review. Clin Oral Implants Res 2018; 29 Suppl 18:37-53. [DOI: 10.1111/clr.13305] [Citation(s) in RCA: 88] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/22/2018] [Indexed: 12/27/2022]
Affiliation(s)
- Andrea Mombelli
- Division of Periodontology; University Clinics of Dental Medicine; University of Geneva; Geneva Switzerland
| | - Dena Hashim
- Division of Periodontology; University Clinics of Dental Medicine; University of Geneva; Geneva Switzerland
| | - Norbert Cionca
- Division of Periodontology; University Clinics of Dental Medicine; University of Geneva; Geneva Switzerland
| |
Collapse
|
33
|
Suárez-López del Amo F, Garaicoa-Pazmiño C, Fretwurst T, Castilho RM, Squarize CH. Dental implants-associated release of titanium particles: A systematic review. Clin Oral Implants Res 2018; 29:1085-1100. [DOI: 10.1111/clr.13372] [Citation(s) in RCA: 78] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 08/16/2018] [Accepted: 08/28/2018] [Indexed: 12/13/2022]
Affiliation(s)
- Fernando Suárez-López del Amo
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Periodontics; University of Oklahoma Health Sciences Center; Oklahoma City Oklahoma
| | - Carlos Garaicoa-Pazmiño
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Periodontics and Oral Medicine; University of Michigan School of Dentistry; Ann Arbor Michigan
| | - Tobias Fretwurst
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Oral and Craniomaxillofacial Surgery, Center for Dental Medicine; University Medical Center Freiburg; Freiburg Germany
| | - Rogerio M. Castilho
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Periodontics and Oral Medicine; University of Michigan School of Dentistry; Ann Arbor Michigan
| | - Cristiane H. Squarize
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Periodontics and Oral Medicine; University of Michigan School of Dentistry; Ann Arbor Michigan
| |
Collapse
|
34
|
Daubert D, Pozhitkov A, McLean J, Kotsakis G. Titanium as a modifier of the peri-implant microbiome structure. Clin Implant Dent Relat Res 2018; 20:945-953. [PMID: 30255621 DOI: 10.1111/cid.12676] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 08/25/2018] [Accepted: 08/28/2018] [Indexed: 12/25/2022]
Abstract
BACKGROUND Recent data support the implication of accelerated titanium dissolution products in peri-implantitis. It is unknown whether these dissolution products have an effect on the peri-implant microbiome, the target of existing peri-implantitis therapies. PURPOSE This study assessed the relationship between the peri-implant microbiome, dissolved titanium levels, and peri-implantitis. MATERIALS AND METHODS Clinical, microbiome, and titanium data were collected from a periodontal population having implants in function for 10 years. Clinical examinations were performed, and submucosal plaque samples were collected from the deepest site per implant. An aliquot of the sample was used for 16S rRNA gene sequencing, with the remainder analyzed for titanium quantity using mass spectrometry. Sequences were clustered into taxonomic units at 97% minimum sequence similarity using the QIIME pipeline approach. RESULTS Fifteen implants were assessed. According to established case definitions, six had a diagnosis of peri-implantitis; nine were healthy. The genera Streptococcus, Prevotella and Haemophilus characterized peri-implant health. Peri-implantitis was associated with a marked increase in Veillonella. Quantities of dissolved titanium were identified in 40% of sites. Titanium presence was associated with peri-implant disease status (P = .02) and correlated to the first principal component of the microbiome (rho = 0.552) and its alpha-diversity (rho = -0.496). Canonical correlation analyses found that titanium levels, but not health or disease status of the implant, were significantly associated with the microbiota composition (P = .045). CONCLUSIONS These findings suggest an association between titanium dissolution products and peri-implantitis and support a role for these products in modifying the peri-implant microbiome structure and diversity.
Collapse
Affiliation(s)
- Diane Daubert
- Department of Periodontics, Clinical and Periodontal Research Laboratory, University of Washington, Seattle, WA (Washington), USA
| | - Alexander Pozhitkov
- Department of Restorative Dentistry, University of Washington, Seattle, WA (Washington), USA
| | - Jeffrey McLean
- Department of Periodontics and Oral Health Sciences, University of Washington, Seattle, WA (Washington), USA.,Department of Microbiology, University of Washington, Seattle, WA (Washington), USA
| | - Georgios Kotsakis
- Department of Periodontics, Clinical and Periodontal Research Laboratory, University of Washington, Seattle, WA (Washington), USA
| |
Collapse
|
35
|
Domingo MG, Ferrari L, Aguas S, Alejandro FS, Steimetz T, Sebelli P, Olmedo DG. Oral exfoliative cytology and corrosion of metal piercings. Tissue implications. Clin Oral Investig 2018; 23:1895-1904. [DOI: 10.1007/s00784-018-2626-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Accepted: 09/10/2018] [Indexed: 02/06/2023]
|
36
|
Heyman O, Koren N, Mizraji G, Capucha T, Wald S, Nassar M, Tabib Y, Shapira L, Hovav AH, Wilensky A. Impaired Differentiation of Langerhans Cells in the Murine Oral Epithelium Adjacent to Titanium Dental Implants. Front Immunol 2018; 9:1712. [PMID: 30158922 PMCID: PMC6103475 DOI: 10.3389/fimmu.2018.01712] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Accepted: 07/12/2018] [Indexed: 11/13/2022] Open
Abstract
Peri-implantitis is a destructive inflammatory process affecting tissues surrounding dental implants and it is considered a new global health concern. Human studies have suggested that the frequencies of Langerhans cells (LCs), the main antigen-presenting cells (APCs) of the oral epithelium, are dysregulated around the implants. Since LCs play a role in regulating oral mucosal homeostasis, we studied the impact of dental titanium implants on LC differentiation using a novel murine model. We demonstrate that whereas the percentage of LC precursors (CD11c+MHCII+) increased in the peri-implant epithelium, the frequencies of LCs (CD11c+MHCII+EpCAM+langerin+) were significantly reduced. Instead, a population of partially developed LCs expressing CD11c+MHCII+EpCAM+ but not langerin evolved in the peri-implant mucosa, which was also accompanied by a considerable leukocyte infiltrate. In line with the increased levels of LC precursors, expression of CCL2 and CCL20, chemokines mediating their translocation to the epithelium, was elevated in the peri-implant epithelium. However, expression of TGF-β1, the major cytokine driving final differentiation of LCs, was reduced in the epithelium. Further analysis revealed that while the expression of the TGF-β1 canonical receptor activing-like kinase (ALK)5 was upregulated, expression of its non-canonical receptor ALK3 was decreased. Since titanium ions releasing from implants were proposed to alter APC function, we next analyzed the impact of such ions on TGF-β1-induced LC differentiation cultures. Concurring with the in vivo studies, the presence of titanium ions resulted in the generation of partially developed LCs that express CD11c+MHCII+EpCAM+ but failed to upregulate langerin expression. Collectively, these findings suggest that titanium dental implants have the capacity to impair the development of oral LCs and might subsequently dysregulate immunity in the peri-implant mucosa.
Collapse
Affiliation(s)
- Oded Heyman
- Department of Periodontology, Faculty of Dental Medicine, Hebrew University-Hadassah Medical Center, Jerusalem, Israel
| | - Noam Koren
- Faculty of Dental Medicine, The Institute of Dental Sciences, Hebrew University, Jerusalem, Israel
| | - Gabriel Mizraji
- Department of Periodontology, Faculty of Dental Medicine, Hebrew University-Hadassah Medical Center, Jerusalem, Israel.,Faculty of Dental Medicine, The Institute of Dental Sciences, Hebrew University, Jerusalem, Israel
| | - Tal Capucha
- Faculty of Dental Medicine, The Institute of Dental Sciences, Hebrew University, Jerusalem, Israel
| | - Sharon Wald
- Faculty of Dental Medicine, The Institute of Dental Sciences, Hebrew University, Jerusalem, Israel
| | - Maria Nassar
- Faculty of Dental Medicine, The Institute of Dental Sciences, Hebrew University, Jerusalem, Israel
| | - Yaara Tabib
- Faculty of Dental Medicine, The Institute of Dental Sciences, Hebrew University, Jerusalem, Israel
| | - Lior Shapira
- Department of Periodontology, Faculty of Dental Medicine, Hebrew University-Hadassah Medical Center, Jerusalem, Israel
| | - Avi-Hai Hovav
- Faculty of Dental Medicine, The Institute of Dental Sciences, Hebrew University, Jerusalem, Israel
| | - Asaf Wilensky
- Department of Periodontology, Faculty of Dental Medicine, Hebrew University-Hadassah Medical Center, Jerusalem, Israel
| |
Collapse
|
37
|
Martínez-González JM, Martín-Ares M, Martínez-Rodríguez N, Barona-Dorado C, Sanz-Alonso J, Cortés-Bretón-Brinkmann J, Ata-Ali J. Comparison of peri-implant soft tissues in submerged versus transmucosal healing: A split mouth prospective immunohistochemical study. Arch Oral Biol 2018; 90:61-66. [PMID: 29549712 DOI: 10.1016/j.archoralbio.2018.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2018] [Revised: 02/21/2018] [Accepted: 03/10/2018] [Indexed: 10/17/2022]
Abstract
OBJECTIVE The present split-mouth prospective study involves an immunohistochemical evaluation of peri-implant soft tissue healing after the osseointegration period, comparing submerged and transmucosal approaches using two-piece implant systems. The null hypothesis was that both surgical procedures elicit a similar immune response of the peri-implant soft tissues. DESIGN Thirty-one healthy patients were included in this study, in which two implants were placed in the right and left maxillary pre-molar regions. A total of 62 dental implants were analyzed, establishing a control side with 31 submerged implants, and a study side with 31 exposed implants bearing healing abutments. After a three-month healing period, a soft tissue biopsy was collected and prepared for immunohistochemical analysis of the proportions of different lymphocyte subpopulations. RESULTS The comparative analysis between the submerged and transmucosal approaches failed to identify statistically significant differences in CD19+ B cells, CD4+ T cells, CD8+ T cells, CD25+ T cells or γd T cells. However, significant differences in NK lymphocytes (p = 0.012) were recorded with the submerged surgical procedure. CONCLUSIONS Peri-implant soft tissue immune response with submerged or transmucosal healing protocols demonstrated comparable outcomes after the osseointegration period. There is sufficient evidence that the null hypothesis of no difference cannot be rejected. To the best of our knowledge, this is the first study of its kind. Further research is therefore needed to further clarify the role of these lymphocyte subpopulations in peri-implant soft tissues.
Collapse
Affiliation(s)
| | - María Martín-Ares
- Department of Medicine and Oral Surgery, Faculty of Dentistry, Complutense University of Madrid, Spain.
| | | | - Cristina Barona-Dorado
- Department of Medicine and Oral Surgery, Faculty of Dentistry, Complutense University of Madrid, Spain
| | - Javier Sanz-Alonso
- Department of Medicine and Oral Surgery, Faculty of Dentistry, Complutense University of Madrid, Spain
| | | | - Javier Ata-Ali
- Department of Dentistry, European University of Valencia, Valencia, Spain; Public Dental Health Service, Arnau de Vilanova Hospital, Valencia, Spain
| |
Collapse
|
38
|
Sajnóg A, Hanć A, Koczorowski R, Makuch K, Barałkiewicz D. Usefulness of laser ablation ICP-MS for analysis of metallic particles released to oral mucosa after insertion of dental implants. J Trace Elem Med Biol 2018; 46:46-54. [PMID: 29413110 DOI: 10.1016/j.jtemb.2017.11.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 09/29/2017] [Accepted: 11/10/2017] [Indexed: 11/24/2022]
Abstract
Despite the fact that titanium is considered highly biocompatible, its presence in the oral cavity (an environment of frequently changing pH and temperature) may result in the release of titanium from intraosseous implants into the oral mucosa, causing a range of reactions from the human body. Fragments of oral mucosa collected from patients after dental implant insertion were analyzed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The study revealed an elevated content of elements (Ti, Al, V) which are components of the metal implants and temporary cover screws. Dynamic ablation of the tissue surface was used in order to obtain maps of the content and distribution of analyzed elements. The material consisted of 30 oral mucosa tissue fragments collected 3-5 months after implantation and 10 samples collected before implantation (control group). The application of optical microscope allowed for indication and confirmation of the location of metal particles prior to LA-ICP-MS analysis. The so-obtained map permitted location of regions containing metal particles. LA-ICP-MS analysis revealed groups of samples with similar properties of metal particles, thus confirming that those metal particles were the main source of the elevated content of metals (Ti, Al, V) in the tissue after implantation. A calibration strategy based on matrix matched solid standards with powdered egg white proteins as matrix material was applied with 34S as an internal standard. The accuracy of the analytical method was verified by ablating pellets of certified reference material ERM-BB422 Fish muscle.
Collapse
Affiliation(s)
- Adam Sajnóg
- Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznan, Umultowska 89b, 61-614 Poznan, Poland
| | - Anetta Hanć
- Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznan, Umultowska 89b, 61-614 Poznan, Poland
| | - Ryszard Koczorowski
- Clinic of Geriatric Dentistry, Karol Marcinkowski University of Medical Sciences in Poznań, Bukowska 70, 60-812 Poznan, Poland
| | - Krzysztof Makuch
- Clinic of Geriatric Dentistry, Karol Marcinkowski University of Medical Sciences in Poznań, Bukowska 70, 60-812 Poznan, Poland
| | - Danuta Barałkiewicz
- Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznan, Umultowska 89b, 61-614 Poznan, Poland.
| |
Collapse
|
39
|
Fretwurst T, Nelson K, Tarnow DP, Wang HL, Giannobile WV. Is Metal Particle Release Associated with Peri-implant Bone Destruction? An Emerging Concept. J Dent Res 2017; 97:259-265. [PMID: 29130804 DOI: 10.1177/0022034517740560] [Citation(s) in RCA: 124] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Peri-implant diseases affecting the surrounding structures of endosseous dental implants include peri-implant mucositis and peri-implantitis. The prevalence of peri-implantitis ranges between 15% and 20% after 10 y, highlighting the major challenge in clinical practice in the rehabilitation of dental implant patients. The widespread nature of peri-implant bone loss poses difficulties in the management of biological complications affecting the long-term success of osseointegrated implant reconstructions. Metal and titanium particles have been detected in peri-implant supporting tissues. However, it remains unclear what mechanisms could be responsible for the elicitation of particle and ion release and whether these released implant-associated materials have a local and/or systemic impact on the peri-implant soft and hard tissues. Metal particle release as a potential etiologic factor has been intensively studied in the field of orthopedics and is known to provoke aseptic loosening around arthroplasties and is associated with implant failures. In dental medicine, emerging information about metal/titanium particle release suggests that the potential impact of biomaterials at the abutment or bone interfaces may have an influence on the pathogenesis of peri-implant bone loss. This mini-review highlights current evidence of metal particle release around dental implants and future areas for research.
Collapse
Affiliation(s)
- T Fretwurst
- 1 Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, USA.,2 Department of Oral and Craniomaxillofacial Surgery, Center for Dental Medicine, University Medical Center Freiburg, Freiburg, Germany
| | - K Nelson
- 2 Department of Oral and Craniomaxillofacial Surgery, Center for Dental Medicine, University Medical Center Freiburg, Freiburg, Germany
| | - D P Tarnow
- 3 College of Dental Medicine, Columbia University, New York, NY, USA
| | - H-L Wang
- 1 Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, USA
| | - W V Giannobile
- 1 Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, USA.,4 Department of Biomedical Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
40
|
Tasat DR, Domingo MG, Bruno ME, Guglielmotti MB, Olmedo DG. Titanium Nanoparticle Size Influences Trace Concentration Levels in Skin Appendages. Toxicol Pathol 2017; 45:624-632. [DOI: 10.1177/0192623317711808] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
As a result of biotribocorrosion, the surface of a titanium (Ti) biomedical device can be a potential source of systemic contamination with Ti nanoparticles (NPs). Although NPs can be chemically similar, differences in particle size may lead to different biological responses. The aim of this experimental study was to determine Ti trace levels in skin appendages and plasma and explore the influence of NP size on trace levels using a murine model. Results showed the presence of Ti traces in the nails, hair, and plasma. The concentration of the smallest NPs (5 Nm) was higher than that of 10 Nm NPs in all the studied samples. Irrespective of NP size, Ti levels were always lower in plasma than in skin appendages. Ti levels were higher in nails than in hair. Ti NPs size influenced trace concentration levels in hair/nails, suggesting that 5 Nm Ti particles are more easily eliminated through these skin appendages. Given that the nails showed the highest levels of Ti, and that these skin appendages are not exposed to agents that can leach out Ti, as occurs with hair, we propose the nails as the most suitable and reliable bioindicator for monitoring systemic contamination with Ti.
Collapse
Affiliation(s)
- Deborah R. Tasat
- School of Science and Technology, National University of General San Martín, San Martín, Buenos Aires, Argentina
- Department of Histology and Embryology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
| | - Mariela G. Domingo
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
| | - Marcos E. Bruno
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
| | - María B. Guglielmotti
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
- National Research Council (CONICET), Buenos Aires, Argentina
| | - Daniel G. Olmedo
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
- National Research Council (CONICET), Buenos Aires, Argentina
| |
Collapse
|
41
|
Cionca N, Hashim D, Mombelli A. Zirconia dental implants: where are we now, and where are we heading? Periodontol 2000 2016; 73:241-258. [DOI: 10.1111/prd.12180] [Citation(s) in RCA: 141] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
42
|
Tasat DR, Bruno ME, Domingo M, Gurman P, Auciello O, Paparella ML, Evelson P, Guglielmotti MB, Olmedo DG. Biokinetics and tissue response to ultrananocrystalline diamond nanoparticles employed as coating for biomedical devices. J Biomed Mater Res B Appl Biomater 2016; 105:2408-2415. [DOI: 10.1002/jbm.b.33777] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 07/12/2016] [Accepted: 08/14/2016] [Indexed: 02/02/2023]
Affiliation(s)
- Deborah R. Tasat
- School of Science and Technology; National University of San Martin; Buenos Aires Argentina
- Department of Histology and Embryology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
| | - Marcos E. Bruno
- School of Science and Technology; National University of San Martin; Buenos Aires Argentina
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
| | - Mariela Domingo
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
- Research Fellow of the National Inter-university Council; Buenos Aires Argentina
| | - Pablo Gurman
- Department of Materials Science and Engineering; University of Texas-Dallas; Richardson Texas United States of America
| | - Orlando Auciello
- Departments of Materials Science and Engineering and Biomedical Engineering; University of Texas-Dallas; Richardson Texas United States of America
| | - María L. Paparella
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
| | - Pablo Evelson
- General and Inorganic Chemistry Division; School of Pharmacy and Biochemistry, University of Buenos Aires; Buenos Aires Argentina
- National Research Council (CONICET); Buenos Aires Argentina
| | - María B. Guglielmotti
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
- National Research Council (CONICET); Buenos Aires Argentina
| | - Daniel G. Olmedo
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
- National Research Council (CONICET); Buenos Aires Argentina
| |
Collapse
|
43
|
Ogawa ES, Matos AO, Beline T, Marques IS, Sukotjo C, Mathew MT, Rangel EC, Cruz NC, Mesquita MF, Consani RX, Barão VA. Surface-treated commercially pure titanium for biomedical applications: Electrochemical, structural, mechanical and chemical characterizations. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 65:251-61. [DOI: 10.1016/j.msec.2016.04.036] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 03/17/2016] [Accepted: 04/11/2016] [Indexed: 01/04/2023]
|
44
|
Cubela M, Soljic V, Kero D, Vukojevic K, Govorko DK, Saraga-Babic M. Comparison of proliferation, apoptosis and expression of syndecan-1 and α-SMA in edentulous ridge oral mucosa of successful and early failed submerged dental implants—An immunohistochemical study. Arch Oral Biol 2016; 66:155-64. [DOI: 10.1016/j.archoralbio.2016.02.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 02/18/2016] [Accepted: 02/26/2016] [Indexed: 11/30/2022]
|
45
|
Production of a biofunctional titanium surface using plasma electrolytic oxidation and glow-discharge plasma for biomedical applications. Biointerphases 2016; 11:011013. [PMID: 26984234 DOI: 10.1116/1.4944061] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
In this study, the authors tested the hypotheses that plasma electrolytic oxidation (PEO) and glow-discharge plasma (GDP) would improve the electrochemical, physical, chemical, and mechanical properties of commercially pure titanium (cpTi), and that blood protein adsorption on plasma-treated surfaces would increase. Machined and sandblasted surfaces were used as controls. Standard electrochemical tests were conducted in artificial saliva (pHs of 3.0, 6.5, and 9.0) and simulated body fluid. Surfaces were characterized by scanning electron microscopy, energy-dispersive spectroscopy, x-ray photoelectron spectroscopy, atomic force microscopy, x-ray diffraction, profilometry, Vickers microhardness, and surface energy. For biological assay, the adsorption of blood serum proteins (i.e., albumin, fibrinogen, and fibronectin) was tested. Higher values of polarization resistance and lower values of capacitance were noted for the PEO and GDP groups (p < 0.05). Acidic artificial saliva reduced the corrosion resistance of cpTi (p < 0.05). PEO and GDP treatments improved the surface properties by enrichment of the surface chemistry with bioactive elements and increased surface energy. PEO produced a porous oxide layer (5-μm thickness), while GDP created a very thin oxide layer (0.76-μm thickness). For the PEO group, the authors noted rutile and anatase crystalline structures that may be responsible for the corrosion barrier improvement and increased microhardness values. Plasma treatments were able to enhance the surface properties and electrochemical stability of titanium, while increasing protein adsorption levels.
Collapse
|
46
|
Halperin-Sternfeld M, Sabo E, Akrish S. The Pathogenesis of Implant-Related Reactive Lesions: A Clinical, Histologic and Polarized Light Microscopy Study. J Periodontol 2016; 87:502-10. [PMID: 26832832 DOI: 10.1902/jop.2016.150482] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND Peri-implant soft tissue reactive lesions (I-RLs) may jeopardize implant success and survival. To the best of the authors' knowledge, its pathogenesis is unknown. The objective of this study is to conduct a clinicopathologic and polarized light microscopy (PLM) analysis of 14 new I-RLs and compare them with comparable tooth-associated cases (T-RLs) to better understand I-RL pathogenesis. METHODS Fifty-eight new cases of I-RL and T-RL were retrieved from the pathology department archives of Rambam Health Care Campus, Haifa, Israel. Retrospective analysis of histopathologic and clinical features was conducted, documented, and then compared for: 1) I-RL (n = 14), 2) peri-implant pyogenic granuloma (I-PG) (n = 5), 3) peri-implant peripheral giant cell granuloma (I-PGCG) (n = 9), 4) T-RL (n = 44), 5) tooth-associated pyogenic granuloma (T-PG) (n = 21), and 6) tooth-associated peripheral giant cell granuloma (T-PGCG) (n = 23). Presence of foreign bodies was assessed using PLM. RESULTS Foreign bodies were found more commonly in I-RLs (n = 13/14; 93%) when compared with T-RLs (n = 18/44; 41%), which was a statistically significant difference (P = 0.01) with an odds ratio of 7.9. Microscopically, I-PGCG was associated with: 1) lower multinucleated giant cell count (P = 0.04); 2) lower density of mesenchymal cells (P = 0.05); and 3) more diffuse, non-lobulated stromal morphology (P = 0.001). Clinically, I-RLs were found in patients who were older, and all cases were located in the posterior region: mandible (n = 12/14; 86%) and maxilla (n = 2/14; 14%). CONCLUSIONS In cases of implant failure, implantation of foreign bodies may play a role with subsequent development of I-PG and I-PGCG-like lesions. Clinicians should be aware of this risk so they can implement measures to minimize adverse implant outcomes.
Collapse
Affiliation(s)
- Michal Halperin-Sternfeld
- Department of Periodontology, School of Graduate Dentistry, Rambam Health Care Campus, Haifa, Israel
| | - Edmond Sabo
- Department of Pathology, Rambam Health Care Campus.,Bruce Rappaport Faculty of Medicine, Technion, Israel Institute of Technology, Haifa, Israel
| | - Sharon Akrish
- Department of Pathology, Rambam Health Care Campus.,Bruce Rappaport Faculty of Medicine, Technion, Israel Institute of Technology, Haifa, Israel.,Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus
| |
Collapse
|
47
|
Pozhitkov AE, Daubert D, Brochwicz Donimirski A, Goodgion D, Vagin MY, Leroux BG, Hunter CM, Flemmig TF, Noble PA, Bryers JD. Interruption of Electrical Conductivity of Titanium Dental Implants Suggests a Path Towards Elimination Of Corrosion. PLoS One 2015; 10:e0140393. [PMID: 26461491 PMCID: PMC4604158 DOI: 10.1371/journal.pone.0140393] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 09/24/2015] [Indexed: 01/30/2023] Open
Abstract
Peri-implantitis is an inflammatory disease that results in the destruction of soft tissue and bone around the implant. Titanium implant corrosion has been attributed to the implant failure and cytotoxic effects to the alveolar bone. We have documented the extent of titanium release into surrounding plaque in patients with and without peri-implantitis. An in vitro model was designed to represent the actual environment of an implant in a patient’s mouth. The model uses actual oral microbiota from a volunteer, allows monitoring electrochemical processes generated by biofilms growing on implants and permits control of biocorrosion electrical current. As determined by next generation DNA sequencing, microbial compositions in experiments with the in vitro model were comparable with the compositions found in patients with implants. It was determined that the electrical conductivity of titanium implants was the key factor responsible for the biocorrosion process. The interruption of the biocorrosion current resulted in a 4–5 fold reduction of corrosion. We propose a new design of dental implant that combines titanium in zero oxidation state for osseointegration and strength, interlaid with a nonconductive ceramic. In addition, we propose electrotherapy for manipulation of microbial biofilms and to induce bone healing in peri-implantitis patients.
Collapse
Affiliation(s)
- Alex E. Pozhitkov
- Department of Oral Health Sciences, University of Washington, Box 357444, Seattle, Washington, United States of America
- * E-mail:
| | - Diane Daubert
- Department of Periodontics, University of Washington, Box 357444, Seattle, Washington, United States of America
| | - Ashley Brochwicz Donimirski
- Department of Oral Health Sciences, University of Washington, Box 357444, Seattle, Washington, United States of America
| | - Douglas Goodgion
- Department of Oral Health Sciences, University of Washington, Box 357444, Seattle, Washington, United States of America
| | - Mikhail Y. Vagin
- Department of Physics, Chemistry and Biology (IFM) Linköping University, SE-581 83, LINKÖPING, Sweden
| | - Brian G. Leroux
- Department of Oral Health Sciences, University of Washington, Box 357444, Seattle, Washington, United States of America
| | - Colby M. Hunter
- PhD Program in Microbiology, Alabama State University, Montgomery, Alabama, United States of America
| | - Thomas F. Flemmig
- Faculty of Dentistry, The University of Hong Kong, Prince Philip Dental Hospital, 34 Hospital Road, Sai Ying Pun, Hong Kong SAR, Peoples’ Republic of China
| | - Peter A. Noble
- PhD Program in Microbiology, Alabama State University, Montgomery, Alabama, United States of America
| | - James D. Bryers
- Department of Bioengineering, University of Washington, 3720 15th Avenue NE, Seattle, Washington, United States of America
| |
Collapse
|
48
|
Yu F, Addison O, Davenport AJ. A synergistic effect of albumin and H₂O₂ accelerates corrosion of Ti6Al4V. Acta Biomater 2015; 26:355-65. [PMID: 26238758 DOI: 10.1016/j.actbio.2015.07.046] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Revised: 07/22/2015] [Accepted: 07/30/2015] [Indexed: 10/23/2022]
Abstract
The synergistic effect of albumin and H2O2 on corrosion of titanium alloy Ti6Al4V in physiological saline was investigated with long-term immersion tests and electrochemical methods. It was found that in the presence of both albumin and H2O2, the rate of metal release in immersion tests was far higher than in the presence of either species alone. Electrochemical polarisation curves and potentiostatic tests showed that H2O2 increased both the rates of the anodic and cathodic reactions, whilst albumin significantly decreased the rate of the cathodic reaction and slightly decreased the rate of the anodic reaction. The synergistic effect of albumin and H2O2 during immersion tests was attributed to the effect of adsorption of albumin in lowering the rate of the cathodic reaction and thus lowering the open circuit potential into the active region of titanium where complexation by H2O2 increased the corrosion rate. The corrosion attack was found to be greater in the β-phase of the alloy. The findings suggest that current standard tests in physiological or phosphate-buffered saline may underestimate the rate of corrosion in the peri-implant environment, in which albumin is the predominant protein, and reactive oxygen species such as H2O2 can occur as a result of inflammatory reactions in response to surgery, infection, or implant corrosion products. STATEMENT OF SIGNIFICANCE Corrosion of many biomedical implant materials occurs in the body leading to adverse biological responses. Several components of the environment into which a metal implant is placed including proteins and products of cellular physiology, been shown to modify corrosion resistance. Previously all studies on such components including the common protein albumin and the inflammatory product H2O2 have considered the effects of these species in isolation. For the first time we report a synergistic interaction between albumin and H2O2 significantly accelerating corrosion of Ti6Al4V at physiological pH and temperature. This is attributed to an increased rate of the anodic reaction caused by H2O2 complexation of Ti, suppression of cathodic reaction by albumin adsorption shifting OCP to the active region of Ti6Al4V.
Collapse
|
49
|
Paknejad M, Bayani M, Yaghobee S, Kharazifard MJ, Jahedmanesh N. Histopathological evaluation of gingival tissue overlying two-stage implants after placement of cover screws. BIOTECHNOL BIOTEC EQ 2015. [DOI: 10.1080/13102818.2015.1066234] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
50
|
Faverani LP, Fogaça JF, Machado T, Silva EA, Barão VAR, Assunção WG. Does Surface Topography Improve Electrochemical Behavior of Ti–6Al–4V Alloy in Different Saliva pH Levels? ACTA ACUST UNITED AC 2015. [DOI: 10.1007/s40735-015-0020-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|