1
|
Castagnini F, Bordini B, Cosentino M, Diquattro E, Gorgone M, Traina F. Head size in Delta ceramic-on-ceramic total hip arthroplasty: a comparative registry study. Arch Orthop Trauma Surg 2024; 144:4163-4170. [PMID: 39225803 DOI: 10.1007/s00402-024-05504-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2024] [Accepted: 08/14/2024] [Indexed: 09/04/2024]
Abstract
INTRODUCTION Optimal bearing size in total hip arthroplasty (THA) has not been clearly ascertained, but large diameter ceramic balls may improve function and implant stability, with minimal concerns for wear. Delta ceramic-on-ceramic (COC) THA were stratified based on head diameter (32, 36 and 40 mm), aiming to assess: 1) survival rates, reasons for revision and hazard ratios for failure; 2) survival rates and hazard ratios for aseptic loosening, dislocation/primary instability, liner failure. MATERIALS AND METHODS A regional arthroplasty registry was enquired about Delta COC THA performed for primary osteoarthritis, stratified by head size. 13,161 primary cementless THAs were included in the study, with a mean follow-up of 5.7 years (range: 0-17): 3980 (30.2%) 32 mm balls, 8327 (63.3%) 36 mm heads, 854 (6.5%) 40 mm heads. RESULTS The three cohorts achieved similar survival rates (p = 0.99) and adjusted hazard ratios (p > 0.05). No revisions for head breakage or metallosis occurred. When revision for cup aseptic loosening was the endpoint, the survival rates of three cohorts (p = 0.08) and the adjusted hazard ratios (p > 0.05) were similar. The three cohorts achieved comparable survival rates when revision for dislocation/primary instability was the endpoint (p = 0.08). When the endpoint was revision for liner breakage, 32 mm cohort showed higher rates of revision (p = 0.01). No liner failure was detected in the 40 mm cohort. CONCLUSIONS 32 mm, 36 mm and 40 mm provided similar 10-year survival rates in Delta COC THA. 40 mm heads emerged as safe options but did not lower the revisions for dislocations/primary instability. LEVEL OF EVIDENCE IV (therapeutic study).
Collapse
Affiliation(s)
- Francesco Castagnini
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
| | - Barbara Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Monica Cosentino
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Emanuele Diquattro
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - Mara Gorgone
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - Francesco Traina
- Head of Ortopedia-Traumatologia e, Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
- DIBINEM, Università di Bologna, Bologna, Italy
| |
Collapse
|
2
|
Mihalko WM, Jove M, Jove N, Calkins TE, Gehlert RJ. United States Experience With a Femoral Neck Retaining Total Hip Arthroplasty Stem: A Retrospective Study With Control Comparison From the Literature. J Arthroplasty 2024; 39:750-753. [PMID: 37640246 DOI: 10.1016/j.arth.2023.08.074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 08/21/2023] [Accepted: 08/22/2023] [Indexed: 08/31/2023] Open
Abstract
BACKGROUND Femoral neck retaining prostheses have gained popularity in Europe, but the United States has not seen the same trends occurring. Previous reports demonstrate high survivorship for these implants, but to our knowledge, there are no reports examining US data. METHODS After institutional review board approval, 824 primary total hip arthroplasties utilizing a femoral neck-retaining prosthesis were examined for femoral component survivorship rates. European studies were systematically reviewed to determine survivorship rates. The data were used to formulate a Kaplan-Meier survivorship curve and compare US data to that of the European studies. RESULTS European studies demonstrated survivorship rates for all causes of 97.7 and 99.0% for aseptic loosening at an average of 6 years (range, 4.5 to 10). The current study demonstrated an all-cause 94% Kaplan-Meier survivorship estimate at 5 years and when aseptic loosening only was considered, survivorship increased to 99.4% at 5 years and 98.4% at 11 years. CONCLUSION This femoral neck-retaining prosthesis demonstrated excellent survivorship that is comparable to the rates seen in European studies as well as the rates of standard and mid-stem prostheses in the United States.
Collapse
Affiliation(s)
- William M Mihalko
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Maurice Jove
- Atlanta Bone and Joint Specialists, Atlanta, Georgia
| | - Nathan Jove
- Atlanta Bone and Joint Specialists, Atlanta, Georgia
| | - Tyler E Calkins
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Rick J Gehlert
- Department of Orthopaedic Surgery, University of New Mexico, Albuquerque, New Mexico
| |
Collapse
|
3
|
Pardo F, Giardina F, Ancarani C, Bordini B, Castagnini F, Perdisa F, Traina F. Higher failure rate of secondary patellar resurfacing following bicompartmental knee arthroplasty. Arch Orthop Trauma Surg 2023; 143:6315-6321. [PMID: 37261480 DOI: 10.1007/s00402-023-04924-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 05/21/2023] [Indexed: 06/02/2023]
Abstract
INTRODUCTION The role of secondary patellar resurfacing (SPR) in anterior knee pain (AKP) is still debated in literature. A regional arthroplasty registry was investigated, aiming to: (1) assess the survival rate of SPR; and (2) compare SPR to tricompartmental TKA. MATERIALS AND METHODS The regional arthroplasty registry RIPO was investigated about all SPRs performed after bicompartmental arthroplasty. The survival rates and the reasons for revision were assessed as any other factor that could have influenced implants failure. SPR survivorship was compared to tricompartmental TKAs. RESULTS 406 SPRs performed after bicompartmental arthroplasty were analyzed. The survival rates were 80.6% (CI 95% 75.9-84.5) at 5 years and 77.6% (CI 95% 72.4-82) at 7 years. Half of the SPRs was performed 0.9-2.4 years after the index bicompartmental arthroplasty. SPR achieved lower survival than tricompartmental TKA (80.6% vs 96.7%, p < 0.001), with an adjusted hazard ratio for failure of 5.5 (CI 95% 4.2-7.1, p < 0.001). SPRs performed within 2 years after primary implant had a significantly higher rates of failure when compared to tricompartmental TKA (HR: 6.4, CI 95% 4.8-8.4, p < 0.001). CONCLUSION SPR after bicompartmental knee arthroplasty showed modest 5- and 7-year survival rates, worse than primary tricompartmental TKA. When SPRs are performed within 2 years after primary arthroplasty, a significant higher risk of failure should be expected, highlighting than appropriate pre-operative work-up and patient selection is crucial for SPR successful outcome. LEVEL OF EVIDENCE III, therapeutic study.
Collapse
Affiliation(s)
- Francesco Pardo
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - Federico Giardina
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - Cristina Ancarani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Barbara Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Francesco Castagnini
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
| | | | - Francesco Traina
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
- Orthopaedics and Traumatology, DIBINEM, University of Bologna, Bologna, Italy
| |
Collapse
|
4
|
Pardo F, Castagnini F, Bordini B, Cosentino M, Lucchini S, Traina F. A Modular Head-Neck Adapter System and Ceramic Heads in Revision Hip Arthroplasty: A Registry Study on 354 Implants. J Arthroplasty 2023; 38:1578-1583. [PMID: 36764407 DOI: 10.1016/j.arth.2023.01.055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 01/28/2023] [Accepted: 01/31/2023] [Indexed: 02/12/2023] Open
Abstract
BACKGROUND Five- to 10-year outcomes of a modular head-neck adapter system with ceramic heads in revision hip arthroplasty on large populations are still lacking. A registry study about modular adapter system with Delta ceramic head in revisions was designed, aiming to assess (1) the survival rates of the device, (2) the reasons for re-revisions of the device, and (3) a comparison to factory assembled titanium sleeve and Delta head cohort in revision hips. METHODS Using a regional arthroplasty registry, we investigated the modular adapter system with a ceramic head in revision hips. Demographics, implant features, and reasons for revision were recorded. Survival rates and reasons for re-revision were assessed. The modular adapter system with the ceramic ball was compared to a factory-assembled ceramic titanium-sleeved head in revisions, acting as a control group. There were 354 revisions included at a mean follow-up of 5 years (range, 0 to 13). RESULTS The 5- and 7-year survival rates were 87.9% and 86.9%, respectively. Dislocations (2.8%) and cup aseptic loosening (4.2%) were the 2 most frequent reasons for re-revision. No breakage of the adapter system or the ceramic head occurred. A femoral neck failed (0.3%). No implant features, offset (P = .088) or skirted (P = .870) tapers, impacted on failures. No differences between the 2 cohorts were found regarding survival rates (P = .696) and reasons for re-revision (dislocations, P = .983; cup aseptic loosening, P = .296). CONCLUSION The modular head neck adapter system with a ceramic head seems to be a valid option in revisions at 5 and 7 years, without additional risk of implant breakage in this registry.
Collapse
Affiliation(s)
- Francesco Pardo
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Francesco Castagnini
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Barbara Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Monica Cosentino
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Stefano Lucchini
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Francesco Traina
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy; DIBINEM, University of Bologna, Bologna, Italy
| |
Collapse
|
5
|
Chen A, Paxton L, Zheng X, Peat R, Mao J, Liebeskind A, Gressler LE, Marinac-Dabic D, Devlin V, Cornelison T, Sedrakyan A. Association of Sex With Risk of 2-Year Revision Among Patients Undergoing Total Hip Arthroplasty. JAMA Netw Open 2021; 4:e2110687. [PMID: 34076699 PMCID: PMC8173374 DOI: 10.1001/jamanetworkopen.2021.10687] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
IMPORTANCE The worldwide population is aging and includes more female individuals than male individuals, with higher rates of total hip arthroplasty (THA) among female individuals. Although research on this topic has been limited to date, several studies are currently under way. OBJECTIVES To evaluate the association between sex and 2-year revision after THA. DESIGN, SETTING, AND PARTICIPANTS This cohort study used data from statewide databases in New York and California between October 1, 2015, and December 31, 2018. Patients 18 years or older with osteoarthritis who underwent THA and had sex recorded in the database were included in the analysis. EXPOSURE Total hip arthroplasty. MAIN OUTCOMES AND MEASURES The outcome of interest was the difference in early, all-cause revision surgery rates after primary THA between women and men. The association of sex with the revision rate was examined using Cox proportional hazards regression analysis. RESULTS Of 132 826 patients included in the study, 74 002 (55.7%) were women; the mean (SD) age was 65.9 (11.0) years, and the median follow-up time was 1.3 years (range, 0.0-3.0 years). The 2-year revision rate was 2.5% (95% CI, 2.4%-2.6%) among women and 2.1% (95% CI, 2.0%-2.2%) among men. After adjusting for demographic characteristics, comorbidities, and facility volume, a minimal clinically meaningful difference was observed in revision rates despite women having a higher risk of all-cause revision compared with men (hazard ratio, 1.16; 95% CI, 1.07-1.26; P < .001). The risk of revision was increased among women compared with men in the subgroup of patients who were younger than 55 years (hazard ratio, 1.47; 95% CI, 1.20-1.81; P < .001). CONCLUSIONS AND RELEVANCE In this cohort study, no clinically meaningful difference in all-cause revision rates after primary THA was found between men and women at 2-year follow-up. The modest difference in the risk of revision between men and women in a small subgroup of patients younger than 55 years suggests that the risk of revision in this population should be studied further.
Collapse
Affiliation(s)
- Amanda Chen
- Department of Population Health Sciences, Weill Cornell College of Medicine, New York, New York
| | - Liz Paxton
- Kaiser Permanente, San Diego, California
| | - Xinyan Zheng
- Department of Population Health Sciences, Weill Cornell College of Medicine, New York, New York
| | - Raquel Peat
- Office of Orthopedic Devices, Office of Product Evaluation and Quality, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland
| | - Jialin Mao
- Department of Population Health Sciences, Weill Cornell College of Medicine, New York, New York
| | - Alexander Liebeskind
- Department of Population Health Sciences, Weill Cornell College of Medicine, New York, New York
| | - Laura E. Gressler
- Office of Clinical Evidence and Analysis, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland
| | - Danica Marinac-Dabic
- Office of Clinical Evidence and Analysis, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland
| | - Vincent Devlin
- Office of Orthopedic Devices, Office of Product Evaluation and Quality, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland
| | - Terri Cornelison
- Health of Women Program, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland
| | - Art Sedrakyan
- Department of Population Health Sciences, Weill Cornell College of Medicine, New York, New York
| |
Collapse
|
6
|
Pardo F, Bordini B, Castagnini F, Giardina F, Faldini C, Traina F. Are powder-technology-built stems safe? A midterm follow-up registry study. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2021; 32:10. [PMID: 33471238 PMCID: PMC7817598 DOI: 10.1007/s10856-020-06481-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 12/18/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Powder technology was developed to bring together the mechanical features and high porosity of titanium. However, the high porosity may theoretically compromise mechanical resistance. Literature is deficient about the use and safety profile of cementless femoral implants built using additive manufacturing (in particular electron beam melting technology, EBM). The purpose of this study was to evaluate the survival rates and the reason for revisions (especially implant breakage) of the first two EBM-built stems at a mid-term follow-up, using a joint arthroplasty registry. METHODS The registry of Prosthetic Orthopedic Implant (RIPO) was investigated about cementless stems implanted from 2010 to 2017. Stems built with EBM technology (Parva and Pulchra stems; Adler Ortho, Milan, Italy) were compared to all the other cementless stems implanted during the same period, acting as control group. The survival rates and reasons for revision were assessed. RESULTS No stem breakage occurred. At 5-year follow-up, the survival rates of the two cohorts were not statistically different (96.8% EBM stems, 98.0% standard cementless stems; p > 0.05). In the EBM stems, aseptic loosening occurred in 1.7% of the cases at the latest follow-up. CONCLUSIONS This large cohort showed that mechanical resistance is not a concern in EBM stems at mid-term follow-up. However, larger populations and longer follow-ups are needed to further validate these results.
Collapse
Affiliation(s)
- Francesco Pardo
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via G.C. Pupilli 1, Bologna, 40136, Italy.
| | - Barbara Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, Bologna, 40136, Italy
| | - Francesco Castagnini
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via G.C. Pupilli 1, Bologna, 40136, Italy
| | - Federico Giardina
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via G.C. Pupilli 1, Bologna, 40136, Italy
| | - Cesare Faldini
- Clinica Ortopedica e Traumatologica I, IRCCS Istituto Ortopedico Rizzoli, Via G.C. Pupilli 1, Bologna, 40136, Italy
- DIBINEM, University of Bologna, Bologna, Italy
| | - Francesco Traina
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via G.C. Pupilli 1, Bologna, 40136, Italy
- DIBINEM, University of Bologna, Bologna, Italy
- University of Messina, Messina, Italy
| |
Collapse
|
7
|
Mihalko WM, Haider H, Kurtz S, Marcolongo M, Urish K. New materials for hip and knee joint replacement: What's hip and what's in kneed? J Orthop Res 2020; 38:1436-1444. [PMID: 32437026 DOI: 10.1002/jor.24750] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 04/24/2020] [Accepted: 05/01/2020] [Indexed: 02/04/2023]
Abstract
Over the last three decades there have been significant advancements in the knee and hip replacement technology that has been driven by an issue in the past concerning adverse local tissue reactions, aseptic and septic loosening. The implants and the materials we utilize have improved over the last two decades and in knee and hip replacement there has been a decrease in the failures attributed to wear and osteolysis. Despite these advancements there are still issues with patient satisfaction and early revisions due to septic and aseptic loosening in knee replacement patients. This article reviews the state of current implant material technology in hip and knee replacement surgery, discusses some of the unmet needs we have in biomaterials, and reviews some of the current biomaterials and technology that may be able to solve the most common issues in the knee and hip replacement surgery.
Collapse
Affiliation(s)
- William M Mihalko
- Department of Orthopaedic Surgery and Biomedical Engineering, Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Hani Haider
- Orthopaedic Biomechanics and Advanced Surgical Technologies Laboratory, Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, Omaha, Nebraska
| | - Steven Kurtz
- Exponent Inc., Drexel University, Philadelphia, Pennsylvania
| | - Michele Marcolongo
- Department of Materials Science and Engineering, Drexel University, Philadelphia, Pennsylvania
| | - Kenneth Urish
- Department of Orthopaedic Surgery, Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.,Department of Bioengineering, Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.,Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania
| |
Collapse
|
8
|
Zhang X, Shi G, Sun X, Zheng W, Lin X, Chen G. Factors Influencing the Outcomes of Artificial Hip Replacements. Cells Tissues Organs 2019; 206:254-262. [DOI: 10.1159/000500518] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 04/16/2019] [Indexed: 11/19/2022] Open
Abstract
Hip replacement is one of the most successful surgeries in the clinic for the removal of painful joints. Hip osteoarthritis and femoral head necrosis are the 2 main reasons for hip replacement. Several factors are associated with the outcomes of surgery. Nonsurgical factors include gender, age, body mass index, prosthetic material, and risk factors. Surgical factors are anesthesia, postoperative complications, and rehabilitation. Considering the increasing demand for hip arthroplasty and the rise in the number of revision operations, it is imperative to understand factor-related progress and how modifications of these factors promotes recovery following hip replacement. In this review, we first summarize recent findings regarding crucial factors that influence the outcomes of artificial hip replacement surgery. These findings not only show the time-specific effect for the treatment and recovery from hip arthroplasty in the clinic, but also provide suitable choices for different individuals for clinicians to consider. This, in turn, will help to develop the best possible postoperative program for specific patients.
Collapse
|
9
|
Rose S, Normand SL. Double robust estimation for multiple unordered treatments and clustered observations: Evaluating drug-eluting coronary artery stents. Biometrics 2019; 75:289-296. [PMID: 30004575 PMCID: PMC6330249 DOI: 10.1111/biom.12927] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2017] [Revised: 06/01/2018] [Accepted: 06/01/2018] [Indexed: 12/23/2022]
Abstract
Postmarket comparative effectiveness and safety analyses of therapeutic treatments typically involve large observational cohorts. We propose double robust machine learning estimation techniques for implantable medical device evaluations where there are more than two unordered treatments and patients are clustered in hospitals. This flexible approach also accommodates high-dimensional covariates drawn from clinical databases. The Massachusetts Data Analysis Center percutaneous coronary intervention cohort is used to assess the composite outcome of 10 drug-eluting stents among adults implanted with at least one drug-eluting stent in Massachusetts. We find remarkable discrimination between stents. A simulation study designed to mimic this coronary intervention cohort is also presented and produced similar results.
Collapse
Affiliation(s)
- Sherri Rose
- Department of Health Care Policy, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Sharon-Lise Normand
- Department of Health Care Policy, Harvard Medical School, Boston, Massachusetts, U.S.A
- Department of Biostatistics, Harvard T.H. Chan School of Public Health, Boston, Massachusetts, U.S.A
| |
Collapse
|
10
|
Shin EH, Moon KH. Cementless total hip arthroplasty in young patients under the age of 30: a minimum 10-year follow-up. Hip Int 2018; 28:507-513. [PMID: 29756492 DOI: 10.1177/1120700017752339] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE The purpose of this study was to evaluate the clinical and radiologic outcomes of young patients (under the age of 30) who received a total hip arthroplasty (THA) and in whom patients had been followed for more than 10 years. MATERIALS AND METHODS This retrospective study was conducted for 51 hips (44 patients) that had undergone THA. The mean age for the index operation was 25.71 years, and the mean follow-up period was 13.7 years. Clinical outcomes were evaluated by Harris hip score (HHS), activity level, and complications. Radiographic evaluations were assessed according to osteolysis, loosening, and polyethylene wear. RESULTS The average HHS improved from 67.47 pre-operatively to 97.42 at the final follow-up ( p < 0.001). The activity level changed from 1.92 pre-operatively to 1.33 at the final follow-up ( p < 0.001). Ten cases had undergone revision arthroplasty within the follow-up period, and the overall survival rate was 80.4% at the final follow-up with revision for any reason as the end point. Polyethylene liners were used in all revision cases ( p = 0.003). Patients with modular stem had a higher failure rate than patients with a fully porous coated stem ( p < 0.001). Furthermore, a small diameter head size was associated with a higher risk of revision surgery ( p = 0.003). Complications such as dislocations were found in three hips. CONCLUSION Cementless THA yields encouraging clinical and radiological results in young and active patients under the age of 30. However, the bearing surface, type of stem, and head size influenced component durability and revision rate.
Collapse
Affiliation(s)
- Eun Ho Shin
- Department of Orthopaedic Surgery, Inha University, College of Medicine, Incheon, Korea
| | - Kyoung Ho Moon
- Department of Orthopaedic Surgery, Inha University, College of Medicine, Incheon, Korea
| |
Collapse
|
11
|
Lim SJ, Ryu HG, Eun HJ, Park CW, Kwon KB, Park YS. Clinical Outcomes and Bearing-Specific Complications Following Fourth-Generation Alumina Ceramic-on-Ceramic Total Hip Arthroplasty: A Single-Surgeon Series of 749 Hips at a Minimum of 5-Year Follow-Up. J Arthroplasty 2018; 33:2182-2186.e1. [PMID: 29599034 DOI: 10.1016/j.arth.2018.02.045] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 02/08/2018] [Accepted: 02/08/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study is to evaluate the minimum 5-year outcomes and bearing-specific complications in a single surgeon series of fourth-generation alumina ceramic-on-ceramic total hip arthroplasties (THAs). METHODS We retrospectively analyzed 667 patients (749 hips) who underwent primary THAs by a single surgeon using fourth-generation alumina ceramic bearings. There were 315 men and 352 women with a mean age of 54.2 years. The surgeon used cementless prostheses with an identical design and BIOLOX Delta ceramics in all hips, using a 36-mm head in 472 hips (63%) and a 32-mm head in 227. The mean follow-up duration was 6.5 years (range, 5 to 8 years). RESULTS The mean Harris hip score improved from 45.6 points preoperatively to 91.3 points at final follow-up. All but 1 acetabular cup and all femoral stems were well fixed. No radiographic evidence of osteolysis was identified at final follow-up. There were 2 (0.3%) ceramic liner fractures and no ceramic head fractures. A total of 48 hips (6.4%) exhibited audible noise (29 clickings and 19 squeakings), but no patient required revision. Other complications were 1 dislocation, 1 deep infection, 3 iliopsoas tendonitis, and 6 periprosthetic femoral fractures. Kaplan-Meier survivorship for revision for any reason was 98.6% (95% confidence interval, 97.7-99.5) at 6.5 years. CONCLUSION Delta ceramic-on-ceramic THAs had a high rate of survivorship without radiographic evidence of osteolysis at 6.5-year follow-up. However, we found 0.3% ceramic liner fractures and 6.4% audible noises associated with the use of Delta ceramics.
Collapse
Affiliation(s)
- Seung-Jae Lim
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyung-Gon Ryu
- Department of Orthopaedic Surgery, Seoul Medical Center, Seoul, Korea
| | - Hyeon-Jun Eun
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Chan-Woo Park
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Kyeu-Back Kwon
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Youn-Soo Park
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
12
|
Jacquot L, Bonnin MP, Machenaud A, Chouteau J, Saffarini M, Vidalain JP. Clinical and Radiographic Outcomes at 25-30 Years of a Hip Stem Fully Coated With Hydroxylapatite. J Arthroplasty 2018; 33:482-490. [PMID: 29066107 DOI: 10.1016/j.arth.2017.09.040] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 09/12/2017] [Accepted: 09/15/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Little is known about the survival of total hip arthroplasty implants with bioactive coatings beyond the first 20 years. The authors aimed to report survival of a tapered hip stem fully coated with hydroxylapatite (HA) at follow-up of 25-30 years. METHODS Of the original series of 320 patients (347 hips), 12 patients (12 hips) had stem and cup revisions, 54 patients (55 hips) had cup revisions, 17 patients (17 hips) had liner exchange. A total of 207 patients (225 hips) died with stems in place and 21 patients (24 hips) could not be reached. This left a cohort of 80 patients (86 hips) with their original stem for assessment. Survival was analyzed using the Kaplan-Meier (KM) method and cumulative incidence function (CIF). RESULTS Considering stem revision as endpoint, the revision risk calculated using the KM method was 6.3%, whereas using the CIF it was 3.7%. Considering any reoperation as endpoint, the revision risk calculated using the KM method was 41.2%, whereas using the CIF it was 25.9%. The Harris Hip Score for 77 patients (18 hips) was 81.6 ± 15.2. Standard x-rays were available for 52 hips (49 patients), and 10 (19.2%) showed radiolucencies <2 mm thick. CONCLUSION This study is the first to report outcomes of an HA-coated stem beyond 25 years. The survival of stem compares favorably with long-term survival of the Charnley cemented stem, and with shorter-term registry studies. The stem achieved its intended purpose of total osteointegration in the long-term, although the proximolateral region remains susceptible to radiolucencies.
Collapse
Affiliation(s)
- Laurent Jacquot
- Artro Institute, Annecy Le Vieux, France; Department of Orthopaedic Surgery, Clinique d'Argonay, Centre Le Périclès, Annecy, France
| | - Michel P Bonnin
- Artro Institute, Annecy Le Vieux, France; Ramsay Générale de Santé, Centre Orthopédique Santy, Hôpital PrivéJean Mermoz, Lyon, France
| | - Alain Machenaud
- Artro Institute, Annecy Le Vieux, France; Department of Orthopaedic Surgery, Clinique d'Argonay, Centre Le Périclès, Annecy, France
| | - Julien Chouteau
- Artro Institute, Annecy Le Vieux, France; Department of Orthopaedic Surgery, Clinique d'Argonay, Centre Le Périclès, Annecy, France
| | | | - Jean-Pierre Vidalain
- Artro Institute, Annecy Le Vieux, France; Department of Orthopaedic Surgery, Clinique d'Argonay, Centre Le Périclès, Annecy, France
| |
Collapse
|
13
|
The experience of the RIPO, a shoulder prosthesis registry with 6-year follow-up. Musculoskelet Surg 2017; 102:273-282. [PMID: 29204822 DOI: 10.1007/s12306-017-0529-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Accepted: 11/28/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND Implant registries have proved valuable in assessing the outcomes of arthroplasty procedures. Moreover, by identifying lesser quality implants they have indirectly improved the quality of care. The registry of prosthetic shoulder implants was established in 2008. METHODS It records information on all types of primary and revision arthroplasty procedures involving the glenohumeral joint, including reverse and total arthroplasty, hemiarthroplasty, resurfacing, removal, and any other surgical procedures that are required to manage these patients. The collected data include patient demographics, weight, height, operated side, cuff status, and diagnosis/reason for revision surgery, information on previous surgical procedures involving either shoulder, comorbidities, antibiotic and thromboembolic prophylaxis, blood transfusions, surgical approach, cuff repair procedures performed during arthroplasty, bone grafts, drains, and perioperative complications, and data about the prosthetic components implanted, including the fixation method. RESULTS Procedures were performed on 3754 shoulders. They included 2226 RSA, 320 TSA, 730 HA, 233 resurfacing procedures, 245 revisions, and 77 "other" procedures. The survival curves of the implants are greater than 90%, and no differences were found among prosthesis from different manufacturers. The diagnosis that prompted to arthroplasty was: osteoarthritis in 60.9% of cases and fractures, bone necrosis, sequelae of fracture and rotator cuff tear arthropathy for the rest of implants. DISCUSSION AND CONCLUSION This study describes the epidemiological data and mid-term implant outcomes of the shoulder arthroplasty procedures performed in our region, from 2008 to 2014, and compares them with published data from national registries of similar size. LEVEL OF EVIDENCE III.
Collapse
|
14
|
Howard DP, Wall PDH, Fernandez MA, Parsons H, Howard PW. Ceramic-on-ceramic bearing fractures in total hip arthroplasty. Bone Joint J 2017; 99-B:1012-1019. [DOI: 10.1302/0301-620x.99b8.bjj-2017-0019.r1] [Citation(s) in RCA: 77] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Accepted: 04/24/2017] [Indexed: 12/23/2022]
Abstract
Aims Ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) are commonly used, but concerns exist regarding ceramic fracture. This study aims to report the risk of revision for fracture of modern CoC bearings and identify factors that might influence this risk, using data from the National Joint Registry (NJR) for England, Wales, Northern Ireland and the Isle of Man. Patients and Methods We analysed data on 223 362 bearings from 111 681 primary CoC THAs and 182 linked revisions for bearing fracture recorded in the NJR. We used implant codes to identify ceramic bearing composition and generated Kaplan-Meier estimates for implant survivorship. Logistic regression analyses were performed for implant size and patient specific variables to determine any associated risks for revision. Results A total of 222 852 bearings (99.8%) were CeramTec Biolox products. Revisions for fracture were linked to seven of 79 442 (0.009%) Biolox Delta heads, 38 of 31 982 (0.119%) Biolox Forte heads, 101 of 80 170 (0.126%) Biolox Delta liners and 35 of 31 258 (0.112%) Biolox Forte liners. Regression analysis of implant size revealed smaller heads had significantly higher odds of fracture (chi-squared 68.0, p < 0.001). The highest fracture risk was observed in the 28 mm Biolox Forte subgroup (0.382%). There were no fractures in the 40 mm head group for either ceramic type. Liner thickness was not predictive of fracture (p = 0.67). Body mass index (BMI) was independently associated with revision for both head fractures (odds ratio (OR) 1.09 per unit increase, p = 0.031) and liner fractures (OR 1.06 per unit increase, p = 0.006). Conclusions We report the largest independent study of CoC bearing fractures to date. The risk of revision for CoC bearing fracture is very low but previous studies have underestimated this risk. There is good evidence that the latest generation of ceramic has greatly reduced the odds of head fracture but not of liner fracture. Small head size and high patient BMI are associated with an increased risk of ceramic bearing fracture. Cite this article: Bone Joint J 2017;99-B:1012–19.
Collapse
Affiliation(s)
- D. P. Howard
- University Hospitals Leicester NHS Trust, Gwendolen
Road, Leicester LE5 4PW, UK
| | - P. D. H. Wall
- University Hospitals Coventry & Warwickshire NHS Trust, Clifford Bridge Road, Coventry, UK
| | - M. A. Fernandez
- University Hospitals Coventry & Warwickshire NHS Trust, Clifford Bridge Road, Coventry, UK
| | - H. Parsons
- University Hospitals Coventry & Warwickshire NHS Trust, Clifford Bridge Road, Coventry, UK
| | | |
Collapse
|
15
|
Cementless total hip arthroplasty using Biolox®delta ceramic-on-ceramic bearing in patients with osteonecrosis of the femoral head. Hip Int 2017; 26:144-8. [PMID: 26868115 DOI: 10.5301/hipint.5000311] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/19/2015] [Indexed: 02/04/2023]
Abstract
PURPOSE The purpose of this study was to evaluate the results of cementless total hip arthroplasty (THA) using a 32 mm or larger Biolox®delta ceramic-on-ceramic (CoC) bearing in patients with osteonecrosis of the femoral head after a minimum of 5 years of follow-up. MATERIALS AND METHODS We retrospectively analysed 44 patients (53 hips) who underwent cementless THA using Biolox®delta CoC bearing. There were 33 men (40 hips) and 11 women (13 hips) with the mean age of 49 years. A 36 mm head was used in 42 (79%) of 53 hips and a 32 mm head was used in 11 hips with smaller acetabular shells. The mean duration of follow-up was 5.3 years (range 5-6 years). RESULTS The mean Harris Hip Score improved from 50 points preoperatively to 97 points at final follow-up (p<0.001). All acetabular and femoral components showed radiographic evidence of osseointegration. No osteolysis was observed. No patients sustained ceramic fracture. An audible hip noise was identified in 2 (4%) of the 53 hips (1 squeaking and 1 clicking). Survivorship with revision for any reason at a minimum of 5 years was 100% in the best-case scenario and 95 % in the worst-case scenario. CONCLUSIONS The minimum 5-year results of cementless THA using a 32 mm or larger Biolox®delta CoC bearing in patients with osteonecrosis of the femoral head were encouraging with excellent survivorship. However, it was also found that the risk of noise development remains even for the new alumina matrix composite ceramic.
Collapse
|
16
|
Current expert views on metal-on-metal hip resurfacing arthroplasty. Consensus of the 6th advanced Hip resurfacing course, Ghent, Belgium, May 2014. Hip Int 2017; 26:1-7. [PMID: 26449333 DOI: 10.5301/hipint.5000288] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/05/2015] [Indexed: 02/04/2023]
Abstract
This paper reports the consensus of an international faculty of expert metal-on-metal (MoM) hip resurfacing surgeons, with a combined experience of over 40,000 cases, on the current status of hip resurfacing arthroplasty. Indications, design and metallurgy issues, release of metal ions and adverse soft tissue reactions to particles, management of problematic cases and revisions, as well as required experience and training are covered. The overall consensus is that MoM hip resurfacing should not be banned and should be viewed separately from MoM total hip arthroplasty (THA) with a large diameter head because of the different design and wear behaviour related to the taper/trunnion connection. The use of hip resurfacing has decreased worldwide but specialist centres continue to advocate hip resurfacing in young and active male patients. Regarding age the general recommendation is to avoid hip resurfacing in men older than 65 and in women older than 55, depending on the patient activity and bone quality. Female gender is considered a relative contraindication. Most surgeons would not implant a MoM hip in women who would still like a child. Regardless of gender, there is a consensus not to perform hip resurfacing in case of a femoral head size smaller than 46 mm and in patients with renal insufficiency or with a known metal allergy. Regarding follow-up of hip resurfacing and detection of adverse local tissue reactions, metal ion measurements, MRI and ultrasound are advocated depending on the local expertise. The consensus is that hip resurfacing should be limited to high volume hip surgeons, who are experienced in hip resurfacing or trained to perform hip resurfacing in a specialist centre.
Collapse
|
17
|
Lim SJ, Jang SP, Kim DW, Moon YW, Park YS. Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve. Clin Orthop Relat Res 2015; 473:3781-7. [PMID: 26024582 PMCID: PMC4626516 DOI: 10.1007/s11999-015-4374-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Modern ceramic-on-ceramic bearings have become attractive alternatives to conventional polyethylene in total hip arthroplasty (THA) as a result of their low wear and minimal particle production. However, 28-mm heads in ceramic-on-ceramic bearing couples have been associated with ceramic fracture. To address these issues, 32-mm and larger ceramic heads with a titanium-alloy sleeve have been introduced, although limited data are available on their durability and clinical outcomes. QUESTIONS/PURPOSES We determined (1) the survivorship of the primary ceramic-on-ceramic THA using a 32-mm ceramic head with a titanium-alloy sleeve at a minimum followup of 5 years; (2) Harris hip scores; (3) the incidence of ceramic fracture and noisy hip; and (4) the proportion of hips showing radiographic evidence of osteolysis. METHODS From November 2005 to August 2009, we performed 301 ceramic-on-ceramic THAs using a 32-mm ceramic head with a titanium-alloy sleeve in 270 patients. Of these, 12 patients (12 hips [4%]) died from problems unrelated to surgery and 13 patients (15 hips [5%]) were lost during followup before a minimum of 5 years had been reached, leaving 245 patients who had 274 THAs with a minimum followup of 5 years (mean, 6.5 years; range, 5-9 years) in this retrospective analysis. During the study period, 30% (301 of 997 hips) were performed with this articulation based on the operating surgeon's discretion. The mean patient age at the time of surgery was 55 years (range, 16-82 years). All operations were performed at a single center. All of the ceramic implants were hot isostatic-pressed, laser-marked, proof-tested third-generation alumina. We determined the implant survival, Harris hip scores, incidence of ceramic fracture or noisy hips (based on a questionnaire), and presence of osteolysis. RESULTS The survival rate of ceramic-on-ceramic bearings in primary THA using a 32-mm ceramic head with a titanium-alloy sleeve was 98% (95% confidence interval, 96%-100%) at 9 years. The Harris hip score improved from a mean of 47 points preoperatively to 93 points at last followup. One ceramic head fractured at 6 years postoperatively. No ceramic liners fractured. Audible hip clicking and squeaking were identified in four hips and one hip, respectively. Osteolysis was detected in three hips, but none had symptoms. CONCLUSIONS Primary ceramic-on-ceramic THA using a 32-mm ceramic head with a titanium-alloy sleeve has a survivorship of 98% at 9-year followup. Nevertheless, surgeons should be aware of the potential risks of ceramic fracture, noise, and osteolysis associated with the use of a ceramic head with a titanium-alloy sleeve. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
Affiliation(s)
- Seung-Jae Lim
- Department of Orthopedic Surgery, Sungkyunkwan University School of Medicine, Samsung Medical Center, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710 South Korea
| | - Seung-Pil Jang
- Department of Orthopedic Surgery, Sungkyunkwan University School of Medicine, Samsung Medical Center, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710 South Korea
| | - Dong-Wook Kim
- Department of Orthopedic Surgery, Sungkyunkwan University School of Medicine, Samsung Medical Center, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710 South Korea
| | - Young-Wan Moon
- Department of Orthopedic Surgery, Sungkyunkwan University School of Medicine, Samsung Medical Center, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710 South Korea
| | - Youn-Soo Park
- Department of Orthopedic Surgery, Sungkyunkwan University School of Medicine, Samsung Medical Center, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710 South Korea
| |
Collapse
|
18
|
Affiliation(s)
- James T Ninomiya
- Department of Orthopaedic Surgery, FMLH Specialty Clinics Building, Medical College of Wisconsin, 5200 West Wisconsin Avenue, Milwaukee, WI 53226. E-mail address:
| | - John C Dean
- West Texas Orthopedics, 10 Desta Drive, Suite 100E, Midland, TX 79705
| | - Stephen J Incavo
- Houston Methodist Hospital, Smith Tower, 6550 Fannin Street, Suite 2600, Houston, TX 77030
| |
Collapse
|
19
|
Sedrakyan A, Paxton E, Graves S, Love R, Marinac-Dabic D. National and international postmarket research and surveillance implementation: achievements of the International Consortium of Orthopaedic Registries initiative. J Bone Joint Surg Am 2014; 96 Suppl 1:1-6. [PMID: 25520412 PMCID: PMC4271420 DOI: 10.2106/jbjs.n.00739] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Art Sedrakyan
- Weill Cornell Medical College, 402 East 67th Street, New York, NY 10065
| | - Elizabeth Paxton
- Surgical Outcomes & Analysis Department, Kaiser Permanente, 8954 Rio San Diego Drive, Suite 406, San Diego, CA 92108
| | - Stephen Graves
- Australian Orthopaedic Association National Joint Replacement Registry, Discipline of Public Health, MDP DX 650 511, University of Adelaide, Adelaide, SA 5005, Australia
| | - Rebecca Love
- Surgical Outcomes & Analysis Department, Kaiser Permanente, 8954 Rio San Diego Drive, Suite 406, San Diego, CA 92108
| | - Danica Marinac-Dabic
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993-0002
| |
Collapse
|