1
|
Comparative Evaluation of Microleakage of Flowable Composite Resin Using Etch and Rinse, Self-Etch Adhesive Systems, and Self-Adhesive Flowable Composite Resin in Class V Cavities: Confocal Laser Microscopic Study. MATERIALS 2022; 15:ma15144963. [PMID: 35888429 PMCID: PMC9319247 DOI: 10.3390/ma15144963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/14/2022] [Accepted: 07/14/2022] [Indexed: 12/10/2022]
Abstract
The essential factor in determining the preservation of restoration is the marginal seal. Restoring cervical lesions with a resin composite has always been a challenge. Composite resins with various viscosities and different bonding systems are being researched to reduce the microleakage. Confocal laser scanning microscopy (CLSM) is the latest non-destructive technique for visualizing the microleakage. Objectives: To evaluate and compare the microleakage of Universal Flo composite resin (G-aenial) using etch and rinse adhesive system ER-2 steps (Adper Single Bond 2), self-etch adhesive system SE-1 step (G-Bond), and self-adhesive flowable composite resin (Constic) in Class V cavities using a confocal laser scanning microscope. Materials and Method: Class V cavities were prepared on 27 caries-free human extracted premolar teeth on the buccal and lingual surfaces with standardized dimensions of 2 mm height, width 4 mm, and a depth of 2 mm. After the cavity preparation, all teeth were randomly divided into three groups, namely Group-I: G-aenial Universal Flo with Single Bond 2 (n = 9 teeth); Group-II: G- aenial Universal Flo with G-Bond (n = 9 teeth), and Group-III: Constic (n = 9 teeth). The prepared and restored specimens were then subjected to thermocycling for 500 cycles in a water bath at 5 °C and 55 °C with a dwelling time of 30 s. The specimens were placed in 0.6% aqueous rhodamine dye for 48 h. Sectioning was carried out bucco-lingually and specimens were evaluated for microleakage under a confocal laser scanning microscope. Results: There was a significant difference (p = 0.009) in microleakage when comparing total etch and rinse, specifically between Adper Single Bond 2 ER-2 steps (fifth generation) and self-adhesive flowable composite resin, which is Constic. There was more microleakage in the self-etch bonding agent, particularly G-Bond, SE-1 step (seventh generation), when compared to ER-2 steps (fifth generation bonding agent); however, the results were not statistically significant (p = 0.468). The self-adhesive flowable composite resin showed more microleakage than SE-1 step and ER-2 steps. Conclusions: None of the adhesive systems tested were free from microleakage. However, less microleakage was observed in the total etch and rinse, especially Adper Single Bond 2 (ER-2 steps), than the self-etch adhesive system SE-1 step and self-adhesive flowable composite resin. Clinical significance: Constant research and technological advancements are taking place in dentin adhesives to improve the marginal seal. This has led to the evolution of total acid-etching dentin bonding agents termed as etch and rinse (ER)-2 steps (fifth generation dentin bonding agents) and self-etching (SE) 2 steps, and SE-1 step dentin bonding agents termed as the sixth and seventh generation bonding agents, respectively.
Collapse
|
2
|
Kamatchi M, Ajay R, Gawthaman M, Maheshmathian V, Preethi K, Gayatrikumary T. Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging. Int J Clin Pediatr Dent 2022; 15:204-209. [PMID: 37457209 PMCID: PMC10338951 DOI: 10.5005/jp-journals-10005-2370] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2023] Open
Abstract
Aim This study aims to compare the self-etch adhesive (SEA) and self-adhesive flowable composite (SAF) concerning tensile bond strength (TBS) and marginal integrity by microleakage (µ LK) test in deciduous molars after artificial thermomechanical aging. Materials and methods 120 extracted primary molars were collected. Sixty teeth were mounted for testing TBS. Teeth were restored using SAF (n = 30) and SEA-conventional flowable (CF) composite (n = 30) and subjected to artificial thermal aging. Half the teeth (n = 15) from each material were subjected to mechanical loading (SEA-TBS-L and SAF-TBS-L). The specimens with no-load (NL) served as control (SEA-TBS-NL and SAF-TBS-NL). Class V cavity prepared and restored with SAF (n = 30) and SEA-CF (n = 30) to test µ LK after thermal aging. The subgroups were as same as the TBS based on with or without mechanical loading (SEA-µ LK-L, SEA-µ LK-NL, SAF-µ LK-L, SAF-µ LK-L; n = 15 each). µ LK was determined by employing the dye immersion technique. Results Concerning TBS, there is a significant difference between SEA and SAF with load or no load. Concerning µ LK, there is a significant difference between the materials under loading and no difference was found when not mechanically loaded. Also, concerning both TBS and µ LK, a significant difference was observed between the load and no-load subgroups within each material. Conclusion SAF exhibited higher TBS than the SEA. Mechanical loading not only adversely affected the TBS but also increased the µLK of the compared materials. Clinical Significance Restoring the primary teeth with SAF not only shortens the laborious operatory time but also yields good clinical serviceability with the good bond strength and minimal µ LK, thus preventing premature loss of teeth and consequential malocclusion. How to cite this article Kamatchi M, Ajay R, Gawthaman M, et al. Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging. Int J Clin Pediatr Dent 2022;15(2):204-209.
Collapse
Affiliation(s)
- Mohanraj Kamatchi
- Department of Pedodontics and Preventive Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Ranganathan Ajay
- Department of Prosthodontics and Crown and Bridge, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Murugesan Gawthaman
- Department of Pedodontics and Preventive Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Veerabadhran Maheshmathian
- Department of Pedodontics and Preventive Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Kumaragurubaran Preethi
- Department of Orthodontics and Dentofacial Orthopedics, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Thiyagarajan Gayatrikumary
- Department of Pedodontics and Preventive Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| |
Collapse
|
3
|
Da Silva D, Ceballos L, Fuentes MV. Influence of the adhesive strategy in the sealing ability of resin composite inlays after deep margin elevation. J Clin Exp Dent 2021; 13:e886-e893. [PMID: 34603617 PMCID: PMC8464384 DOI: 10.4317/jced.58689] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 07/05/2021] [Indexed: 01/18/2023] Open
Abstract
Background The aim of this study was to determine the influence of the gingival margin position and the adhesive strategy selected to perform deep margin elevation (DME) in marginal sealing of resin composite inlays by a nanoleakage test. Material and Methods 12 sound third molars were selected and expulsive MOD cavities for inlays were prepared. Experimental groups were established according to gingival margin location (enamel: 1 mm above cemento-enamel junction (CEJ), dentin: 1 mm below CEJ, or DME, and the adhesive strategy used to lute inlays and elevate the gingival margin. Therefore, the six experimental groups were: 1) Enamel + etch-and-rinse adhesive (ERA) Adper Scotchbond 1XT (SB1XT); 2) Dentin + SB1XT; 3) DME + SB1XT; 4) Enamel + self-etching adhesive (SEA) with enamel selective etching Clearfil SE Bond (CSE); 5) Dentin + CSE; 6) DME + CSE. Resin composite inlays were constructed (Gradia Indirect) and all luted with the same resin cement (RelyX ARC). Specimens were submitted to nanoleakage test. Results were analyzed by Kruskal-Wallis and Mann-Whitney U tests with Bonferroni correction (p<0.05). Results A perfect sealing ability was evidenced for experimental groups with gingival margins on enamel. Similar nanoleakage values were determined when CSE adhesive was applied regardless the gingival margin position. The highest silver nitrate infiltration was detected for elevated margins with the ERA SB1XT. Conclusions The SEA Clearfil SE Bond showed higher sealing ability than the ERA Adper Scotchbond 1XT when margins were located on dentin, regardless margin elevation. Gingival margins on enamel together with enamel acid etching provided an excellent sealing with both adhesive systems. Key words:Adhesion, composite inlays, gingival margin, deep margin elevation, marginal seal, nanoleakage test.
Collapse
Affiliation(s)
- Dayana Da Silva
- DDS, PhD, Assistant Professor, IDIBO Research Group, Nursing and Stomatology Department, Health Sciences Faculty, Rey Juan Carlos University. Av. de Atenas, S/N, 28922. Alcorcón, Madrid, Spain
| | - Laura Ceballos
- DDS, PhD, Professor, IDIBO Research Group, Nursing and Stomatology Department, Health Sciences Faculty, Rey Juan Carlos University. Av. de Atenas, S/N, 28922. Alcorcón, Madrid, Spain
| | - María-Victoria Fuentes
- DDS, PhD, Associate Professor, IDIBO Research Group, Nursing and Stomatology Department, Health Sciences Faculty, Rey Juan Carlos University. Av. de Atenas, S/N, 28922. Alcorcón, Madrid, Spain
| |
Collapse
|
4
|
Bond strength of self-adhesive flowable composite resins to dental tissues: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2021; 128:876-885. [PMID: 33838916 DOI: 10.1016/j.prosdent.2021.02.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 02/17/2021] [Accepted: 02/17/2021] [Indexed: 11/24/2022]
Abstract
STATEMENT OF PROBLEM Although the clinical use of self-adhesive flowable composite resins is convenient, the decision to use flowable or conventional composite resin remains controversial. PURPOSE The purpose of this systematic review and meta-analysis was to assess the in vitro bond strength of self-adhesive flowable composite resins to enamel or dentin compared with conventional composite resins using etch-and-rinse or self-etch adhesive systems. MATERIAL AND METHODS Two independent reviewers performed searches in the PubMed (MEDLINE), Cochrane Wiley, Web of Science, Scopus, and Google Scholar databases for studies reporting on the bond strength of self-adhesive flowable and conventional composite resins to enamel and dentin published from January 2010 up to September 2020. A meta-analysis software program was used for the meta-analysis. Comparisons were conducted using standardized mean differences considering the random-effects model (α=.05). RESULTS Twenty-two studies were considered for the meta-analysis. Immediate and long-term bond strength to enamel was improved when a conventional composite resin was used in combination with an adhesive system (P<.001). Bond strength to dentin was improved by using an adhesive system in combination with a conventional composite resin (P<.001). CONCLUSIONS The bond strength of self-adhesive flowable composite resins is lower than that of conventional composite resins, indicating limited ability to bond to enamel and dentin.
Collapse
|
5
|
Abdelraouf RM, Mohammed M, Abdelgawad F. Evaluation of Shear-Bond-Strength of Dental Self-Adhering Flowable Resin-Composite versus Total-Etch One to Enamel and Dentin Surfaces: An In-Vitro Study. Open Access Maced J Med Sci 2019; 7:2162-2166. [PMID: 31456846 PMCID: PMC6698122 DOI: 10.3889/oamjms.2019.579] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Revised: 07/02/2019] [Accepted: 07/07/2019] [Indexed: 11/05/2022] Open
Abstract
AIM This study aimed to assess the shear bond strength of a self-adhering flowable resin composite versus a total-etch one to different surfaces of permanent-molars. MATERIAL AND METHODS Thirty-six sound human permanent molars were used. The teeth were embedded in acrylic blocks, such that their buccal surfaces were shown. The teeth were divided into three groups: Group I: Uncut-Enamel, Group II: Cut-enamel-surfaces with minimal-grinding and Group III: dentin-surfaces. Half of the teeth in each group were used for bonding to a self-adhering flowable resin-composite (Dyad-flow, Kerr, USA). While the other half of each group was bonded to a total-etch flowable resin-composite (Filtek™Z350-XT,3M-ESPE, USA) which necessitate etching and bonding. Teflon-mold was used for constructing resin composite cylinders (3 × 3 mm) over the buccal surfaces. The Dyad-flow was applied in the central hole of the mould placed upon tooth-surface, and then light-cured for 20 seconds. The Filtek-Z350-XT was applied similarly after etching and bonding steps. The teeth were stored in 37°C distilled water for 24 hours. The strength was measured using a universal testing machine and statistically analysed. Modes of failure were studied using digital-microscope. RESULTS Mean values of shear bond strength for the Dyad and Filtek-Z350-XT in the uncut-enamel were 3.5 and 24.6MPa respectively, while that for cut-enamel were 4.5 and 12.7MPa respectively (Both highly statistically significant P ≤ 0.01) and in dentin were 4.3 and 6.7MPa respectively (Statistically significant P ≤ 0.05). The failure mode for Dyad was mainly adhesive (un-cut or cut-enamel 83.3% adhesive and 16.7% mixed, while in dentin 100% adhesive). While the modes of failure for Filtek-Z350-XT in enamel, either cut or un-cut, were 50% cohesive and 50% mixed, whereas in dentin 100% adhesive. CONCLUSION Bonding of self-etch ″Dyad-flow″ flowable resin-composite was lower than the total-etch one in enamel and dentin. Thus further material improvement may be required.
Collapse
Affiliation(s)
- Rasha M Abdelraouf
- Biomaterials Department, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Manar Mohammed
- Department of Pediatric and Community Dentistry, Faculty of Oral and Dental Medicine, October 6 University, Cairo, Egypt
| | - Fatma Abdelgawad
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Cairo University, Cairo, Egypt
| |
Collapse
|
6
|
Poorzandpoush K, Shahrabi M, Heidari A, Hosseinipour ZS. Shear Bond Strength of Self-Adhesive Flowable Composite, Conventional Flowable Composite and Resin-Modified Glass Ionomer Cement to Primary Dentin. Front Dent 2019; 16:62-68. [PMID: 31608338 PMCID: PMC6778611 DOI: 10.18502/fid.v16i1.1111] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2018] [Accepted: 08/04/2018] [Indexed: 11/24/2022] Open
Abstract
Objectives: This study aimed to compare the shear bond strength (SBS) of self-adhesive and conventional flowable composites and resin-modified glass-ionomer cement (RMGIC) to primary dentin. Materials and Methods: In this in vitro, experimental study, the buccal surface of 48 primary canine and first molar teeth was longitudinally sectioned to expose dentin. The teeth were randomly divided into three groups (n=16) of 37.5% phosphoric acid+ OptiBond+ Premise Flow composite (group 1), Vertise Flow composite (group 2) and RMGIC (group 3). A plastic cylindrical mold was placed on the exposed dentin and filled with restorative materials. The samples were then immersed in distilled water at 37°C for 24 hours, subjected to 1000 thermal cycles between 5–55°C and underwent SBS test. The mode of failure was determined under a stereomicroscope. Data were analyzed using one-way ANOVA and Tukey’s test. Results: A significant difference was noted in SBS of the groups (P<0.05). The SBS of conventional flowable composite was significantly higher that of RMGIC and self-adhesive flowable composite (P<0.05). The difference in SBS of RMGIC and self-adhesive flowable composite was not significant (P>0.05). Failure at the dentin-restoration interface (adhesive failure) had the highest frequency in groups 1 and 2. The frequency of adhesive failure was 100% in group 3. Conclusion: Within the limitations of this study, the conventional flowable composite yielded the highest SBS to primary dentin. Self-adhesive flowable composite and RMGIC showed the lowest SBS with no significant difference with each other.
Collapse
Affiliation(s)
- Kiana Poorzandpoush
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Mehdi Shahrabi
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.,Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Alireza Heidari
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Zohre Sadat Hosseinipour
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
7
|
Mishra P, Jaiswal S, Nikhil V, Gupta S, Jha P, Raj S. Evaluation of marginal sealing ability of self-adhesive flowable composite resin in Class II composite restoration: An in vitro study. J Conserv Dent 2018; 21:363-368. [PMID: 30122814 PMCID: PMC6080182 DOI: 10.4103/jcd.jcd_94_18] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Aim: The aim of this study is to evaluate the marginal sealing ability of self-adhesive flowable composite resin when used as a liner in Class II composite restoration with and without aging. Materials and Methods: A total of 120 standardized Class II tooth preparations with gingival margins 1 mm coronal and apical to cementenamel junction (CEJ) were prepared on 60 extracted permanent mandibular molars and were randomly divided into eight equal Groups: Group 1: cavities coronal to CEJ and restored with Dyad flow liner + Herculite ultra, Group 2: same as Group 1 but cavities margins apical to CEJ, Group 5: cavities coronal to CEJ and restored with only Herculite ultra, and Group 6: same as Group 5 but cavities apical to CEJ. Groups 3,4,7,8 were similar to Groups 1,2,5,6, respectively, but were aged for 6 months. After thermocycling, microleakage testing was done using 0.5% basic fuchsin dye. Result: At cervical level, Group 5 exhibited statistically lower (P = 0.006) microleakage than Group 6, and Group 1 showed lesser microleakage than Group 5 (P = 0.162). Group 2 exhibited significantly less microleakage than Group 6 (P = 0.002). Increased microleakage was observed in aging Groups; however, the difference with nonaging Groups was not statistically significant (P > 0.005). Conclusion: Margins of the cavity in cementum can be better sealed by placing self-adhesive liner and is not affected by aging.
Collapse
Affiliation(s)
- Preeti Mishra
- Department of Conservative Dentistry and Endodontics, Subharti Dental College, Meerut, Uttar Pradesh, India
| | - Shikha Jaiswal
- Department of Conservative Dentistry and Endodontics, Subharti Dental College, Meerut, Uttar Pradesh, India
| | - Vineeta Nikhil
- Department of Conservative Dentistry and Endodontics, Subharti Dental College, Meerut, Uttar Pradesh, India
| | - Sachin Gupta
- Department of Conservative Dentistry and Endodontics, Subharti Dental College, Meerut, Uttar Pradesh, India
| | - Padmanabh Jha
- Department of Conservative Dentistry and Endodontics, Subharti Dental College, Meerut, Uttar Pradesh, India
| | - Shalya Raj
- Department of Conservative Dentistry and Endodontics, Subharti Dental College, Meerut, Uttar Pradesh, India
| |
Collapse
|
8
|
Sachdeva P, Goswami M, Singh D. Comparative evaluation of shear bond strength and nanoleakage of conventional and self-adhering flowable composites to primary teeth dentin. Contemp Clin Dent 2016; 7:326-31. [PMID: 27630496 PMCID: PMC5004545 DOI: 10.4103/0976-237x.188549] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Background: The latest advancement in adhesive dentistry is the development of self adhering flowable composite resin which incorporates the self-etch adhesion technology to eliminate the steps of etching, rinsing, priming and bonding. Few studies have addressed resin bonding to primary teeth. Aim: The aim of this study was to compare the shear bond strength and nanoleakage of conventional and self adhering flowable composites to primary teeth dentin. Settings and Design: This study was conducted in the Department of Pedodontics and Preventive Dentistry, I.T.S Dental College, Hospital and Research Centre, Greater Noida; in association with the Department of Mechanical Engineering, I.T.S Engineering College, Greater Noida; and the Advanced Instrumentation Research Facility (AIRF), Jawaharlal Nehru University, New Delhi. Materials and Methods: Sixty of the ninety primary teeth were evaluated for shear bond strength and thirty for nanoleakage. The samples were divided into three groups; Group I – Dyad Flow (Kerr), Group II – Fusio Liquid Dentin (Pentron Clinical Technologies) and Group III – G-aenial Universal Flo (GC). Shear bond strength was determined using a universal testing machine. Nanoleakage pattern was observed under scanning electron microscope. Results: The shear bond strength of conventional flowable composite was significantly greater than self adhering flowable composite (p<0.05). Nanoleakage scores of both conventional and self adhering flowable composites were comparable. Conclusions: Self adhering flowable composites combine properties of composites and self etch adhesives, eliminating the need for separate bond application that simplifies direct restorative procedure. The evolution of self adhering materials could open new horizons for pediatric dentistry.
Collapse
Affiliation(s)
- Priyanka Sachdeva
- Department of Pedodontics and Preventive Dentistry, I.T.S Dental College, Hospital and Research Centre, Greater Noida, Uttar Pradesh, India
| | - Mousumi Goswami
- Department of Pedodontics and Preventive Dentistry, I.T.S Dental College, Hospital and Research Centre, Greater Noida, Uttar Pradesh, India
| | - Darrel Singh
- Department of Pedodontics and Preventive Dentistry, I.T.S Dental College, Hospital and Research Centre, Greater Noida, Uttar Pradesh, India
| |
Collapse
|
9
|
Rahimian-Imam S, Ramazani N, Fayazi MR. Marginal Microleakage of Conventional Fissure Sealants and Self-Adhering Flowable Composite as Fissure Sealant in Permanent Teeth. JOURNAL OF DENTISTRY (TEHRAN, IRAN) 2015; 12:430-5. [PMID: 26884777 PMCID: PMC4754569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
OBJECTIVES Application of sealants is a safe and effective way to prevent occlusal caries in the posterior teeth. A successful sealant therapy depends on good isolation. Decreased steps of adhesive application may enable proper isolation and use of self-adhering flowable composites for sealant therapy. This study sought to compare the marginal microleakage of fissure sealants and self-adhering flowable composites in permanent teeth. MATERIALS AND METHODS This in vitro, experimental study was conducted on 60 extracted human premolar teeth. The teeth were divided randomly into two groups of 30. In the first group, fissure sealant (Clinpro, 3M ESPE, USA) was placed on the teeth. In the second group, self-adhering flowable composite (Vertise Flow, Kerr, USA) was applied as the sealant. Then, both groups were immersed in 0.5% fuchsin dye solution for 24 hours. Sectioned samples were observed with a stereomicroscope for the extent of dye penetration. Data were analyzed using SPSS 21 and the Mann-Whitney test (P<0.05). RESULTS Microleakage in the fissure sealant group was significantly higher than that in the self-adhering flowable composite group (P<0.001). CONCLUSION Microleakage was less using self-adhering flowable composite compared to conventional fissure sealant; therefore, self-adhering flowable composite can be used as a suitable fissure sealant in permanent teeth.
Collapse
Affiliation(s)
- Sara Rahimian-Imam
- Assistant Professor, Children and Adolescents Health Research Center, Oral and Dental Disease Research Center, Department of Pediatric Dentistry, School of Dentistry, Zahedan University of Medical Sciences, Zahedan, Iran
| | - Nahid Ramazani
- Associate Professor, Children and Adolescents Health Research Center, Oral and Dental Disease Research Center, Department of Pediatric Dentistry, School of Dentistry, Zahedan University of Medical Sciences, Zahedan, Iran,Corresponding author: N. Ramazani, Department of Pediatric Dentistry, Dental School, Zahedan University of Medical Sciences, Zahedan, Iran,
| | | |
Collapse
|