1
|
Teanphonkrang S, Suginta W, Sucharitakul J, Fukamizo T, Chaiyen P, Schulte A. An electrochemical method for detecting the biomarker 4-HPA by allosteric activation of Acinetobacterbaumannii reductase C1 subunit. J Biol Chem 2021; 296:100467. [PMID: 33639166 PMCID: PMC8027283 DOI: 10.1016/j.jbc.2021.100467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 02/18/2021] [Accepted: 02/23/2021] [Indexed: 11/19/2022] Open
Abstract
The C1 (reductase) subunit of 4-hydroxy-phenylacetate (4-HPA) 3-hydroxylase (HPAH) from the soil-based bacterium Acinetobacterbaumannii catalyzes NADH oxidation by molecular oxygen, with hydrogen peroxide as a by-product. 4-HPA is a potent allosteric modulator of C1, but also a known urinary biomarker for intestinal bacterial imbalance and for some cancers and brain defects. We thus envisioned that C1 could be used to facilitate 4-HPA detection. The proposed test protocol is simple and in situ and involves addition of NADH to C1 in solution, with or without 4-HPA, and direct acquisition of the H2O2 current with an immersed Prussian Blue–coated screen-printed electrode (PB-SPE) assembly. We confirmed that cathodic H2O2 amperometry at PB-SPEs is a reliable electrochemical assay for intrinsic and allosterically modulated redox enzyme activity. We further validated this approach for quantitative NADH electroanalysis and used it to evaluate the activation of NADH oxidation of C1 by 4-HPA and four other phenols. Using 4-HPA, the most potent effector, allosteric activation of C1 was related to effector concentration by a simple saturation function. The use of C1 for cathodic biosensor analysis of 4-HPA is the basis of the development of a simple and affordable clinical routine for assaying 4-HPA in the urine of patients with a related disease risk. Extension of this principle to work with other allosteric redox enzymes and their effectors is feasible.
Collapse
Affiliation(s)
- Somjai Teanphonkrang
- School of Biomolecular Science and Engineering (BSE), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; School of Chemistry, Institute of Science, The Suranaree University of Technology (SUT), Nakhon Ratchasima, Thailand
| | - Wipa Suginta
- School of Biomolecular Science and Engineering (BSE), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand
| | - Jeerus Sucharitakul
- Department of Biochemistry and Research Unit in Integrative Immuno-Microbial Biochemistry and Bioresponsive Nanomaterials, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Tamo Fukamizo
- Department of Advanced Bioscience, Kindai University, Nara, Japan
| | - Pimchai Chaiyen
- School of Biomolecular Science and Engineering (BSE), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand
| | - Albert Schulte
- School of Biomolecular Science and Engineering (BSE), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; School of Chemistry, Institute of Science, The Suranaree University of Technology (SUT), Nakhon Ratchasima, Thailand.
| |
Collapse
|
2
|
Sripirom J, Sim WC, Khunkaewla P, Suginta W, Schulte A. Simple and Economical Analytical Voltammetry in 15 μL Volumes: Paracetamol Voltammetry in Blood Serum as a Working Example. Anal Chem 2018; 90:10105-10110. [PMID: 30091360 DOI: 10.1021/acs.analchem.8b01135] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Reported is a three-electrode mini-cell for voltammetry in 15 μL solutions. The key device component is a rolled platinum foil of an inverted omega-shaped cross section, which functions as both the electrolyte container and the counter-electrode. The analytical assembly was completed with properly sized working and reference electrodes in the two terminals of the quasi-tubular Pt trough. Its applicability in electrochemical assays of 15 μL solutions was verified by redox mediator voltammetry at graphite and noble metal sensors and by trace lead stripping voltammetry. Real sample analysis was adequate for drug detection in a volunteer's blood, drawn before and 1 or 4 h after ingestion of paracetamol. In line with its known pharmacokinetics, lack of drug as well as drug presence and clearance were proven correctly in the three samples. The mini-cell here is easy to assemble and operate, indefinitely reusable, and offers valuable economy in chemical usage and minimal waste. This is primarily a versatile device for electrochemical laboratory analysis of samples that are available only in small quantities, and cost-effective quantitative screens for expensive high-molecular-weight compounds, products of microsynthesis, physiological microdialysis collections, and finger-prick blood sampling are seen as feasible targets.
Collapse
Affiliation(s)
- Jiyapa Sripirom
- School of Chemistry, Biochemistry - Electrochemistry Research Unit - Institute of Science , Suranaree University of Technology (SUT) , Nakhon Ratchasima 30000 , Thailand
| | - Wei Chung Sim
- School of Chemistry, Biochemistry - Electrochemistry Research Unit - Institute of Science , Suranaree University of Technology (SUT) , Nakhon Ratchasima 30000 , Thailand
| | - Panida Khunkaewla
- School of Chemistry, Biochemistry - Electrochemistry Research Unit - Institute of Science , Suranaree University of Technology (SUT) , Nakhon Ratchasima 30000 , Thailand
| | - Wipa Suginta
- School of Chemistry, Biochemistry - Electrochemistry Research Unit - Institute of Science , Suranaree University of Technology (SUT) , Nakhon Ratchasima 30000 , Thailand
| | - Albert Schulte
- School of Biomolecular Science and Engineering , Vidyasirimedhi Institute of Science and Technology (VISTEC) , Rayong 21210 , Thailand
| |
Collapse
|
3
|
Rawson TM, O’Hare D, Herrero P, Sharma S, Moore LSP, de Barra E, Roberts JA, Gordon AC, Hope W, Georgiou P, Cass AEG, Holmes AH. Delivering precision antimicrobial therapy through closed-loop control systems. J Antimicrob Chemother 2018; 73:835-843. [PMID: 29211877 PMCID: PMC5890674 DOI: 10.1093/jac/dkx458] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Sub-optimal exposure to antimicrobial therapy is associated with poor patient outcomes and the development of antimicrobial resistance. Mechanisms for optimizing the concentration of a drug within the individual patient are under development. However, several barriers remain in realizing true individualization of therapy. These include problems with plasma drug sampling, availability of appropriate assays, and current mechanisms for dose adjustment. Biosensor technology offers a means of providing real-time monitoring of antimicrobials in a minimally invasive fashion. We report the potential for using microneedle biosensor technology as part of closed-loop control systems for the optimization of antimicrobial therapy in individual patients.
Collapse
Affiliation(s)
- T M Rawson
- National Institute for Health Research Health Protection Research Unit in Healthcare Associated Infections and Antimicrobial Resistance, Imperial College London, Hammersmith Campus, Du Cane Road, London, UK
| | - D O’Hare
- Department of Bioengineering, Imperial College London, London, UK
| | - P Herrero
- Department of Electrical and Electronic Engineering, Imperial College London, South Kensington Campus, London, UK
| | - S Sharma
- College of Engineering, Swansea University, Swansea, UK
| | - L S P Moore
- National Institute for Health Research Health Protection Research Unit in Healthcare Associated Infections and Antimicrobial Resistance, Imperial College London, Hammersmith Campus, Du Cane Road, London, UK
- Imperial College Healthcare NHS Trust, Hammersmith Hospital, Du Cane Road, Acton, UK
| | - E de Barra
- Imperial College Healthcare NHS Trust, Hammersmith Hospital, Du Cane Road, Acton, UK
| | - J A Roberts
- University of Queensland Centre for Clinical Research, Faculty of Medicine and Centre for Translational Pharmacodynamics, School of Pharmacy, The University of Queensland, Brisbane, Australia
- Royal Brisbane and Women’s Hospital, Brisbane, Australia
| | - A C Gordon
- Section of Anaesthetics, Pain Medicine & Intensive Care, Imperial College London, London, UK
| | - W Hope
- Department of Molecular and Clinical Pharmacology, University of Liverpool, Liverpool, UK
| | - P Georgiou
- Department of Electrical and Electronic Engineering, Imperial College London, South Kensington Campus, London, UK
| | - A E G Cass
- Department of Chemistry & Institute of Biomedical Engineering, Imperial College London, Kensington Campus, London, UK
| | - A H Holmes
- National Institute for Health Research Health Protection Research Unit in Healthcare Associated Infections and Antimicrobial Resistance, Imperial College London, Hammersmith Campus, Du Cane Road, London, UK
- Imperial College Healthcare NHS Trust, Hammersmith Hospital, Du Cane Road, Acton, UK
| |
Collapse
|
4
|
Teanphonkrang S, Schulte A. Automated Quantitative Enzyme Biosensing in 24-Well Microplates. Anal Chem 2017; 89:5261-5269. [DOI: 10.1021/acs.analchem.6b04694] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Somjai Teanphonkrang
- School of Chemistry, Institute of Science, ‡Biochemistry−Electrochemistry
Research Unit, Institute of Science, and §Center of Excellence (CoE) in Advanced
Functional Materials, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
| | - Albert Schulte
- School of Chemistry, Institute of Science, ‡Biochemistry−Electrochemistry
Research Unit, Institute of Science, and §Center of Excellence (CoE) in Advanced
Functional Materials, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
| |
Collapse
|