Gillmann K, Hornbeak DM. Rates of visual field change and functional progression in glaucoma following trabecular microbypass implantation of iStent technologies: a meta-analysis. BMJ Open Ophthalmol 2024; 9:e001575. [PMID: 38360043 PMCID: PMC10875546 DOI: 10.1136/bmjophth-2023-001575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 01/30/2024] [Indexed: 02/17/2024] Open
Abstract
BACKGROUND/AIM While intraocular pressure (IOP) remains the only modifiable risk factor for glaucoma progression, the ultimate goal of glaucoma management is to preserve patients' functional vision and quality of life. To this end, minimally invasive glaucoma surgeries (MIGSs) aim to reduce IOP with minimal eye trauma. Commonly used MIGS devices include iStent technologies, which have well-documented IOP-reducing potential and favourable safety profiles. However, no study concluded on their effect on the rates of visual field (VF) changes. The aim of this meta-analysis is to determine the long-term effect of iStent technology implantation on glaucoma functional progression. METHODS Electronic medical literature databases were searched to identify studies reporting on iStent technologies. Reports with follow-up durations <12 months, retention rates <75% and missing VF data were excluded. Fifteen studies reporting on 1115 eyes were identified. The overall weighted mean VF mean deviation (MD) progression, IOP reduction and follow-up duration were calculated. RESULTS Weighted mean IOP at baseline was 19.0±3.1 mm Hg. At the end of a 37.9-month mean follow-up (range 12-96 months), a weighted mean 26.6% IOP reduction was achieved (range 15.2%-42.3%). Over the same duration, the weighted mean VF MD progression rate was -0.02±0.34 dBs/year, from a mean baseline of -5.76±5.68 dBs. CONCLUSION In this review, which examines functional stability of 1115 eyes, iStent technologies achieved a mean rate of progression of -0.024 dBs/year with serial standard automated perimetry, which is similar to that reported in non-glaucomatous eyes and slower than that reported in medically treated glaucoma.
Collapse
Affiliation(s)
- Kevin Gillmann
- Genève Ophtalmologie, Geneva, Switzerland
- Stanford University, Palo Alto, California, USA
| | | |
Collapse
|
2
|
Kim M, Rho S, Lim SH. Five-Year Outcomes of Single Trabecular Microbypass Stent (iStent ®) Implantation with Phacoemulsification in Korean Patients. Ophthalmol Ther 2023; 12:3281-3294. [PMID: 37792244 PMCID: PMC10640437 DOI: 10.1007/s40123-023-00824-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 09/19/2023] [Indexed: 10/05/2023] Open
Abstract
INTRODUCTION This study reports the long-term intraocular pressure (IOP)-lowering efficacy and safety of a single trabecular microbypass stent (iStent®; Glaukos Corp., San Clemente, CA, USA) for medically controlled open-angle glaucoma in Korean patients. METHODS This retrospective observational study included 42 eyes of 35 patients with primary open-angle glaucoma (POAG). All subjects underwent single first-generation iStent® implantation with phacoemulsification by a single surgeon with 5 years follow-up. The primary outcomes were changes in IOP and the number of antiglaucoma medications compared to the preoperative values. The secondary outcome was the proportion of eyes with IOP ≤ 18 mmHg without medication, ≤ 15 mmHg without medication, and ≤ 18 mmHg with or without medication. Adverse events and need for secondary glaucoma surgery were also recorded. RESULTS The mean IOP decreased from 15.8 ± 2.8 to 13.8 ± 1.7 mmHg and the mean number of medications was reduced from 2.24 ± 1.18 to 0.83 ± 1.12, respectively, at year 5. At 3 and 5 years, 80.6% and 78.6% of eyes, respectively, were receiving fewer medications than preoperative numbers. In contrast, only 50% of eyes on four preoperative medications showed medication reductions at 5 years. At years 3 and 5, 61.3% and 53.5% of eyes achieved IOP ≤ 18 mmHg without medication, whereas 90.3% and 89.3% of eyes achieved ≤ 18 mmHg regardless of medication use, respectively. Four eyes required additional glaucoma surgery (two Ahmed glaucoma valve implantations, one trabeculectomy, and one XEN 45 Gel Stent implantation), and all were receiving four preoperative antiglaucoma medications. Transient IOP elevation (14.3%) was the most common complication, followed by five hyphema, one stent obstruction, one stent malposition, and one severe anterior chamber reaction. CONCLUSION This study demonstrated a good safety profile and sustained IOP reduction after the implantation of a single trabecular microbypass stent (iStent®) with phacoemulsification in Korean patients. The majority of subjects with POAG showed a relatively good response; however, eyes receiving a higher number of medications preoperatively (especially four medications) had difficulty achieving a low target IOP.
Collapse
Affiliation(s)
- Myungjin Kim
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, South Korea
| | - Seungsoo Rho
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, South Korea
| | - Su-Ho Lim
- Department of Ophthalmology, Daegu Veterans Health Service Medical Center, #60 Wolgok-Ro, Dalseo-Gu, Daegu, 42835, Republic of Korea.
| |
Collapse
|
3
|
Chan PPM, Larson MD, Dickerson JE, Mercieca K, Koh VTC, Lim R, Leung EHY, Samuelson TW, Larsen CL, Harvey A, Töteberg-Harms M, Meier-Gibbons F, Shu-Wen Chan N, Sy JB, Mansouri K, Zhang X, Lam DSC. Minimally Invasive Glaucoma Surgery: Latest Developments and Future Challenges. Asia Pac J Ophthalmol (Phila) 2023; 12:537-564. [PMID: 38079242 DOI: 10.1097/apo.0000000000000646] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 10/12/2023] [Indexed: 12/21/2023] Open
Abstract
The development of minimally invasive glaucoma surgeries (MIGSs) was intended to provide safe and modestly efficacious modalities for early intervention of mild-to-moderate glaucoma, with minimal trauma and rapid recovery. They were mainly ab interno procedures that reduce intraocular pressure by facilitating the aqueous outflow by bypassing the trabecular meshwork resistance, reinforcing the uveoscleral flow via the supraciliary space, and reducing aqueous production by the ciliary body. While the cumulating evidence helps shape the role of the available MIGS, the exponential new development and advancement in this field has expanded the territory of MIGS. Apart from developing subconjunctival MIGS filtration devices (Xen gel stent and PRESERFLO MicroShunt), there is a tendency to revisit the "traditional" MIGS for alternative use and to modify the procedures with consideration of the fundamental aqueous outflow physiology. Combined MIGS has also been suggested, based on the theory that their different mechanisms may provide additive or synergistic effects. The advancement of laser procedures is also promising and could supplement unmet needs along the glaucoma treatment algorithm. This review examines the broad array of MIGS, updates the recent findings, discusses their potential alternative applications, and explores future challenges.
Collapse
Affiliation(s)
- Poemen P M Chan
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
- Department of Ophthalmology and Visual Sciences, Lam Kin Chung. Jet King-Shing Ho Glaucoma Treatment and Research Centre, The Chinese University of Hong Kong, Hong Kong, China
| | | | - Jaime E Dickerson
- Sight Sciences, Menlo Park, CA, USA
- University of North Texas Health Science Center, North Texas Eye Research Institute, Fort Worth, TX, USA
| | | | - Victor Teck Chang Koh
- Department of Ophthalmology, National University Health System, Singapore
- Centre for Innovation and Precision Eye Health, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Ridia Lim
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Enne Hiu Ying Leung
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
| | - Thomas W Samuelson
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | - Christine L Larsen
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | | | - Marc Töteberg-Harms
- Department of Ophthalmology, Augusta University, Medical College of Georgia, Augusta, GA, USA
| | | | | | - Jessica Belle Sy
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Baguio General Hospital and Medical Center, Baguil City, Benguet, Philippines
| | - Kaweh Mansouri
- Glaucoma Center, Swiss Visio, Clinique de Montchoisi, Lausanne, Switzerland
| | - Xiulan Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Dennis S C Lam
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
- The International Eye Research Institute of The Chinese University of Hong Kong (Shenzhen), Shenzhen, China
| |
Collapse
|
4
|
Fea AM, Ricardi F, Cariola R, Rossi A. Hydrus microstent for the treatment of primary open-angle glaucoma: overview of its safety and efficacy. Expert Rev Med Devices 2023; 20:1009-1025. [PMID: 37752854 DOI: 10.1080/17434440.2023.2259788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 09/13/2023] [Indexed: 09/28/2023]
Abstract
INTRODUCTION Minimally invasive glaucoma surgeries (MIGS) are now a consolidated reality in many surgical units. The Hydrus Microstent is one of several MIGS devices bypassing trabecular outflow and had excellent results over the years. This article aims to review the key features of the Hydrus Microstent in terms of design, efficacy, and safety. AREAS COVERED The present review analyses the main characteristics of the device by evaluating the technical and physical details of its functioning. The evidence that supports a clinical decision summarizes the most influential clinical trials and the most accurate systematic reviews. EXPERT OPINION The Hydrus device has been extensively studied regarding biocompatibility and outflow potential. The subsequent clinical studies have been well-built and proved that the device effectively reduces intraocular pressure (IOP) and the eyedrop load. The device covers almost a quarter of Schlemm's canal circumference, offering at least two advantages: cannulating the Schlemm's canal provides evidence that the device has been implanted correctly; covering a larger area potentially allows to target multiple collector channels or at least areas of active outflow. This scaffold may prove more effective in naïve patients or subjects who used antiglaucoma eyedrops for a limited period, as the prolonged use of hypotonic medications has been associated with the surgical failure of ab interno microhook trabeculotomy.
Collapse
Affiliation(s)
- Antonio M Fea
- Institute of Ophthalmology, Department of Surgical Sciences, University of Turin, Turin, Italy
| | - Federico Ricardi
- Institute of Ophthalmology, Department of Surgical Sciences, University of Turin, Turin, Italy
| | - Rossella Cariola
- Institute of Ophthalmology, Department of Surgical Sciences, University of Turin, Turin, Italy
| | - Alessandro Rossi
- Institute of Ophthalmology, Department of Surgical Sciences, University of Turin, Turin, Italy
| |
Collapse
|
5
|
Wagner IV, Ang B, Checo L, Simsek D, Draper C, Dorairaj S. Spotlight on Schlemm's Canal MicroStent Injection in Patients with Glaucoma. Clin Ophthalmol 2023; 17:1557-1564. [PMID: 37288002 PMCID: PMC10243342 DOI: 10.2147/opth.s388293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 05/30/2023] [Indexed: 06/09/2023] Open
Abstract
Minimally invasive glaucoma surgery (MIGS) has revolutionized glaucoma care with its favorable safety profile and ability to delay or minimize the need for traditional, bleb-based procedures. Microstent device implantation is a type of angle-based MIGS, which reduces intraocular pressure (IOP) through bypass of the juxtacanalicular trabecular meshwork (TM) and facilitation of aqueous outflow into the Schlemm's canal. Although there are limited microstent devices on the market, multiple studies have evaluated the safety and efficacy of iStent® (Glaukos Corp.), iStent Inject® (Glaukos Corp.), and Hydrus® Microstent (Alcon) in the treatment of mild-to-moderate open-angle glaucoma, with and without concurrent phacoemulsification. This review attempts to provide a comprehensive evaluation of injectable angle-based microstent MIGS devices in the treatment of glaucoma.
Collapse
Affiliation(s)
| | - Bryan Ang
- Department of Ophthalmology, Tan Tock Seng Hospital, Singapore
| | - Leticia Checo
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
| | - Derya Simsek
- Department of Ophthalmology, Baskent University Medical School, Ankara, Turkey
| | | | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
| |
Collapse
|
6
|
Assessment of the Effectiveness of Glaucoma Treatment Using MicroPulse Transscleral Cyclophotocoagulation in Patients with Glaucoma Who Have Previously Undergone Vitreoretinal Surgery. Ophthalmol Ther 2023; 12:179-193. [PMID: 36324053 PMCID: PMC9834444 DOI: 10.1007/s40123-022-00598-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Accepted: 10/15/2022] [Indexed: 11/06/2022] Open
Abstract
INTRODUCTION This retrospective study aimed to assess the effectiveness of using MicroPulse transscleral cyclophotocoagulation (µP-TSCPC) in patients who had previously undergone pars plana vitrectomy (PPV), depending on the endotamponade used. METHODS For the study, a total of 60 patients were enrolled who underwent PPV followed by tμP-TSCPC as a result of an increase in intraocular pressure (IOP) over the norm of 21 mmHg. In this group of patients, 20 received silicone oil endotamponade during PPV, 20 received sulfur hexafluoride gas SF6, and in another 20 a differentiated balanced salt solution (BSS) was used. RESULTS The main indications for conducting PPV were (1) retinal detachment (silicone oil endotamponade was used; n = 12); (2) dislocation/subluxation of the patient's own or artificial intraocular lens (balanced salt solution (BSS) endotamponade was used; n = 11); (3) the presence of an epiretinal membrane and/or a macular hole (BSS endotamponade was used; n = 9, or SF6; n = 20); and (4) hemorrhage into the vitreous chamber (silicone oil endotamponade was used; n = 8). CONCLUSION The choice of endotamponade used during PPV was not found to determine the effectiveness of µP-TSCPC treatment. The effectiveness of µP-TSCPC in patients after PPV depended, above all, on the etiology of the disease, for which PPV was previously performed. The lowest effectiveness of µP-TSCPC was noted in cases where the reason for conducting PPV was hemorrhage into the vitreous chamber and silicone oil endotamponade was used, while the highest effectiveness was noted in cases where PPV was conducted owing to the presence of an epiretinal membrane and/or a macular hole and SF6 endotamponade was used.
Collapse
|
7
|
Khalilova TA, Zaitseva AA, Koveshnikov AI. [Micro-invasive glaucoma surgery]. Vestn Oftalmol 2023; 139:90-95. [PMID: 37942602 DOI: 10.17116/oftalma202313905190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
Glaucoma is a severe, rapidly progressing disease that in the absence of proper treatment leads to blindness in 20% of patients. According to the World Glaucoma Association, this disease is the most socially significant in modern ophthalmology and requires searching for new and effective methods of treatment. This article presents the results of research and reviews on this issue, considers both conservative therapy and surgical methods of treatment, analyzes in detail modern methods of micro-invasive eye surgery actively used in clinical practice. The article also describes indications for a various types of interventions, as well as the effect achieved by them and the possible complications, and presents the conclusions about the possibility of using these procedures in wide clinical practice.
Collapse
Affiliation(s)
- T A Khalilova
- S.N. Fedorov National Medical Research Center "MNTK "Eye microsurgery", Moscow, Russia
| | | | | |
Collapse
|
8
|
Effectiveness and Safety of iStent Infinite Trabecular Micro-Bypass for Uncontrolled Glaucoma. J Glaucoma 2023; 32:9-18. [PMID: 36260288 PMCID: PMC9722368 DOI: 10.1097/ijg.0000000000002141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 10/07/2022] [Indexed: 01/24/2023]
Abstract
PRCIS The iStent Infinite Trabecular Micro-Bypass System implanted in patients with open angle glaucoma (OAG) (uncontrolled by prior surgical or medical therapy) was effective in reducing mean diurnal intraocular pressure with a favorable safety profile. PURPOSE The purpose of this study is to evaluate safety and effectiveness of the iStent infinite Trabecular Micro-Bypass System in patients with OAG uncontrolled by prior surgical or medical therapy. DESIGN Prospective, multicenter, single-arm, open-label clinical trial. METHODS Implantation of iStent infinite (3 iStent inject W stents) was performed as a stand-alone surgical procedure in eyes with OAG uncontrolled by prior incisional or cilioablative surgeries or maximum tolerated medical therapy (MTMT). Prospectively declared effectiveness endpoints were proportion of eyes achieving ≥20% mean diurnal intraocular pressure (MDIOP) reduction from baseline at month 12 on the same or fewer intraocular pressure (IOP)-lowering medication classes (responder endpoint) and mean change in MDIOP from baseline at month 12. Safety parameters included visual acuity, slit-lamp and fundus examinations, gonioscopy, perimetry, surgical complications, and adverse events. RESULTS Seventy-two eyes of 72 patients (mean age 71.9 y) with preoperative mean medicated MDIOP of 23.4±2.8 mm Hg on a mean of 3.1±0.9 IOP-lowering medication classes were enrolled: 61 eyes with failed prior surgery/ies (Failed-Surgery subgroup) and 11 eyes uncontrolled on MTMT (MTMT subgroup). A total of 76.1% of all enrolled patients met the responder endpoint (73.4% Failed-Surgery, 90.9% MTMT), with mean reduction (SE) in MDIOP at month 12 of 5.9(0.6) mm Hg [5.5(0.7) mm Hg Failed-Surgery subgroup, 8.1(0.9) mm Hg MTMT subgroup]. For patients on the same or fewer medication(s) as baseline, 53.0% achieved ≥30% MDIOP reduction without surgical interventions/other events. Safety was favorable, with no explants, infection, or device-related interventions or hypotony. CONCLUSIONS iStent infinite stand-alone surgery achieved clinically significant IOP reduction and favorable safety in patients with OAG uncontrolled by prior therapy.
Collapse
|
9
|
Ichioka S, Ishida A, Takayanagi Y, Manabe K, Matsuo M, Tanito M, Tanito M. Roles of Toric intraocular Lens implantation on visual acuity and astigmatism in glaucomatous eyes treated with iStent and cataract surgery. BMC Ophthalmol 2022; 22:487. [PMCID: PMC9749338 DOI: 10.1186/s12886-022-02707-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 11/25/2022] [Indexed: 12/15/2022] Open
Abstract
Background To assess the efficacy of toric intraocular lenses (IOLs) in combined cataract and minimally invasive glaucoma surgery (MIGS), visual and refractive outcomes were compared between eyes implanted with non-toric and toric IOLs during iStent triple procedures. Methods In this retrospective study, open angle glaucoma eyes with preexisting corneal astigmatism of -1.5 diopter (D) or more and implanted with non-toric (n = 9) or toric (n = 9) IOLs were included. The main outcome measures were the intergroup difference in the uncorrected visual acuity (UCVA) and refractive astigmatism at 3 months postoperatively. Results Preoperatively, the logarithm of the minimum angle of resolution (logMAR) UCVAs and refractive astigmatism were equivalent between the groups. Postoperatively, the logMAR UCVA (non-toric, 0.45 ± 0.31; toric, 0.14 ± 0.15; P = 0.021) was significantly better and the refractive astigmatism (non-toric, -2.03 ± 0.63 D; toric, -0.67 ± 0.53 D; P = 0.0014) significantly less in the toric group. The toric group had postoperative improvements in the logMAR UCVA (-0.21, P = 0.020) and refractive astigmatism (+ 1.72 D, P = 0.0039). Vector analyses showed the postoperative centroid magnitude and confidence eclipses of refractive astigmatism was less in the toric group (0.47 D at 173°±0.73D) than the non-toric group (1.10 D at 2°±1.91D). Postoperatively, 78% of eyes in the toric group had 1.0 D or less refractive astigmatism compared with 11% in the non-toric group. Surgically induced astigmatism (non-toric, 0.18 D at 65°; toric, 0.29 D at 137°) did not differ between groups. Conclusion Use of toric IOLs is a reasonable option for better visual outcomes when the combined cataract and iStent surgery is performed in glaucomatous eyes with corneal astigmatism.
Collapse
Affiliation(s)
- Sho Ichioka
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Akiko Ishida
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Yuji Takayanagi
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Kaoru Manabe
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Masato Matsuo
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Masaki Tanito
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Masaki Tanito
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| |
Collapse
|
10
|
Ma GJ, Hwang HB, Yim HB, Kim YC. Short-term Outcomes and Prognostic Factor of Cataract Combined Surgery with iStent Inject versus XEN. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2022. [DOI: 10.3341/jkos.2022.63.9.769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Purpose: To analyze the intraocular pressure (IOP) lowering effect, prognostic factors, and complications that occurred after iStent inject® or XEN® implantation in South Korea.Methods: We retrospectively analyzed 83 eyes with glaucoma who were followed-up for more than 6 months after iStent inject® or XEN® implantation alone or combination with cataract surgery. The success of surgery was defined as an IOP ≤21 mmHg and IOP reduction ≥20% from preoperative IOP.Results: The average IOP drop rate for 6 months after surgery was 33.80% for iStent inject® (group A, 24 eyes), 24.91% for XEN® (group B, 15 eyes), 20.47% for combined iStent inject® and cataract surgery (group A-1, 32 eyes), and 30.39% for combined XEN® and cataract surgery. The cumulative success rate of 6 months after surgery was 45.5% ± 11.2% for group A, 52.8% ± 15.4% for group B, 51.9% ± 9.0% for group A-1, and 83.3% ± 10.8% for group B-1. The difference in success rates between groups A and B was not statistically significant (p = 0.574), and also between groups A-1 and B-1 (p = 0.079).Conclusions: iStent inject® and XEN® both have a significant effect on lowering IOP, regardless of combining cataract surgery. XEN® implantation led to a statistically significant reduction in IOP lowering medications.
Collapse
|
11
|
Lima FLD, Diniz-Filho A, Suzuki ER. Procedimentos Minimamente Invasivos para Glaucoma: uma revisão atualizada da literatura. REVISTA BRASILEIRA DE OFTALMOLOGIA 2022. [DOI: 10.37039/1982.8551.20220105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
12
|
Inatani M, Kohama I, Chu A. iStent Trabecular Micro-bypass Stent Implantation Combined with Phacoemulsification for Open-Angle Glaucoma: A 2-Year Post-marketing Surveillance Study in Japan. Adv Ther 2022; 39:4076-4093. [PMID: 35790641 PMCID: PMC9402767 DOI: 10.1007/s12325-022-02207-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/24/2022] [Indexed: 11/18/2022]
Abstract
Introduction We report 2-year outcomes after implantation of iStent trabecular micro-bypass stent with phacoemulsification, in Japanese patients with mild–moderate open-angle glaucoma (OAG). Methods This was a 24-month, prospective, longitudinal, observational, post-marketing study conducted between July 2017 and September 2020. Patients consisted of adults with OAG on antiglaucoma medications who had cataract surgery combined with one iStent implantation. Outcome measures included intraocular pressure (IOP), antiglaucoma medications, treatment success rates (defined as eyes having lower IOP with same or reduced number of medications from baseline, or same IOP with reduced number of medications from baseline, and not requiring secondary glaucoma surgeries postoperatively), and safety. Outcomes were analyzed in the overall cohort and in glaucoma subtypes: primary OAG, normal-tension glaucoma, and exfoliative glaucoma. Results Overall, 232 eyes were enrolled. At 24 months, mean ± standard deviation IOP decreased from 17.6 ± 4.0 mmHg preoperatively to 14.3 ± 3.0 mmHg (p < 0.05), and mean number of medications reduced from 2.2 ± 1.2 preoperatively to 0.7 ± 1.2 (p < 0.05). Similar trends were observed across glaucoma subtypes. In the overall cohort, 96.7%, 95.3%, and 93.7% of patients achieved treatment success at 6, 12, and 24 months, respectively. There were 67.6% medication-free eyes at 24 months compared to 3.2% medication-free eyes preoperatively (p < 0.0001). Safety profile was favorable over the 2-year period. Conclusions Following iStent implantation with phacoemulsification, clinically relevant and statistically significant reductions in IOP and number of medications were observed in Japanese eyes with OAG over 2 years, with favorable safety profile. These reductions were observed across all glaucoma subtypes. Supplementary Information The online version contains supplementary material available at 10.1007/s12325-022-02207-0.
Collapse
Affiliation(s)
- Masaru Inatani
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Eiheiji, Yoshida, Fukui, 910-1193, Japan.
| | | | - Alice Chu
- Glaukos Corporation, Singapore, Singapore
| |
Collapse
|
13
|
Lim R. The surgical management of glaucoma: A review. Clin Exp Ophthalmol 2022; 50:213-231. [PMID: 35037376 DOI: 10.1111/ceo.14028] [Citation(s) in RCA: 37] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 11/20/2021] [Accepted: 11/28/2021] [Indexed: 01/26/2023]
Abstract
After a long period of little change, glaucoma surgery has experienced a dramatic rise in the number of possible procedures in the last two decades. Glaucoma filtering surgeries with mitomycin C and glaucoma drainage devices remain the standard of surgical care. Other newer surgeries, some of which are minimally or microinvasive glaucoma surgeries, target existing trabecular outflow, enhance suprachoroidal outflow, create subconjunctival blebs, or reduce aqueous production. Some require the implantation of a device such as the iStent, Hydrus, Ex-PRESS, XEN and PRESERFLO, whilst others do not-Trabectome, Kahook dual blade, Ab interno canaloplasty, gonioscopy-assisted transluminal trabeculotomy, OMNI and excimer laser trabeculotomy. Others are a less destructive variation of an established procedure, such as micropulse transscleral cyclophotocoagulation, endoscopic cyclophotocoagulation and ultrasound cycloplasty. Cataract surgery alone can be a significant glaucoma operation. These older and newer glaucoma surgeries, their mechanism of action, efficacy and complications are the subject of this review.
Collapse
Affiliation(s)
- Ridia Lim
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia.,Save Sight Institute, Sydney Medical School, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia
| |
Collapse
|
14
|
Paletta Guedes RA, Gravina DM, Paletta Guedes VM, Chaoubah A. Standalone Implantation of 2-3 Trabecular Micro-Bypass Stents (iStent inject ± iStent) as an Alternative to Trabeculectomy for Moderate-to-Severe Glaucoma. Ophthalmol Ther 2022; 11:271-292. [PMID: 34825352 PMCID: PMC8770764 DOI: 10.1007/s40123-021-00424-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 11/01/2021] [Indexed: 12/04/2022] Open
Abstract
INTRODUCTION This retrospective consecutive study compared standalone implantation of multiple (2-3) trabecular micro-bypass stents (iStent inject ± iStent) (Multi-Stent group) vs trabeculectomy + mitomycin C (Trab group) in moderate to severe open-angle glaucoma (OAG). METHODS Eligible patients underwent Multi-Stent or Trab surgery from 2018 to 2020 and had at least 3-month follow-up; visual field mean deviation (VF MD) - 6 dB or worse; inadequate prior response to maximum medications ± laser procedures; and had trabeculectomy as their next planned intervention. Primary effectiveness, safety-adjusted treatment success, was defined as ≥ 20% intraocular pressure (IOP) reduction on the same or fewer medications, without clinically significant safety events (severe complications, secondary surgeries, reinterventions). Secondary effectiveness included mean IOP and medications; qualified and complete attainment of target IOP (≤ 21/18/15/12 mmHg and > 6 mmHg); health-economic and quality-of-life (QoL) measures; and 2-vs-3-stent subgroup analysis. RESULTS The baseline groups (n = 70 Multi-Stent/40 Trab) were similar: mean IOP (21.1 mmHg/22.3 mmHg); medications (2.87/3.10 medications); disease stage (30%/35% severe); VF MD (- 10.1 dB/- 10.4 dB); and mean last follow-up (LFU, 13.1 months/15.7 months) (all differences non-significant). Primary effectiveness: treatment success at LFU was 62.9% vs 30.0% in Multi-Stent vs Trab eyes, respectively (p = 0.001). Secondary effectiveness: At LFU in Multi-Stent vs Trab groups, respectively: mean IOP decreased by 31% to 14.2 mmHg (p < 0.001) vs by 43% to 12.5 mmHg (p < 0.001); mean medications decreased by 51% to 1.31 medications (p < 0.001) vs by 84% to 0.43 medications (p < 0.001). Multi-Stent eyes, compared to Trab eyes, had fewer visits ± reinterventions within 3 months (3.6 vs 6.1, p < 0.001); longer time to first reintervention (12.2 months vs 4.5 months, p = 0.01); fewer total reinterventions (0.26 vs 0.75, p = 0.006); and earlier lifting of postoperative restrictions (12.6 vs 32.1 days, p < 0.001). In 2-vs-3-stent analysis, there was a trend toward more 3-stent eyes achieving target IOP than 2-stent eyes. Visual fields remained stable in both Multi-Stent and Trab eyes. CONCLUSION Implanting 2-3 trabecular micro-bypass stents was a viable alternative to trabeculectomy for moderate-to-severe OAG, with clinically appropriate IOP/medication reductions and higher safety-adjusted treatment success vs trabeculectomy.
Collapse
Affiliation(s)
- Ricardo Augusto Paletta Guedes
- Paletta Guedes Eye Institute, Juiz de Fora, Brazil.
- Federal University of Juiz de Fora, 79, Oscar Vidal Street, Juiz de Fora, MG, Brazil.
| | | | | | - Alfredo Chaoubah
- Federal University of Juiz de Fora, 79, Oscar Vidal Street, Juiz de Fora, MG, Brazil
| |
Collapse
|
15
|
Salimi A, Watt H, Harasymowycz P. Long-term outcomes of two first-generation trabecular micro-bypass stents (iStent) with phacoemulsification in primary open-angle glaucoma: eight-year results. EYE AND VISION 2021; 8:43. [PMID: 34782017 PMCID: PMC8594216 DOI: 10.1186/s40662-021-00263-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 10/11/2021] [Indexed: 02/06/2023]
Abstract
Background The short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up. Methods This longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery. Eight-year efficacy outcomes included mean intraocular pressure (IOP) and medications, as well as surgical success. Eight-year safety outcomes included best-corrected visual acuity (BCVA), visual field mean deviation (VF-MD), cup-to-disc ratio (CDR), retinal nerve fiber layer (RNFL) thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, and adverse events. Results A total of 62 eyes with primary open-angle glaucoma (POAG) were included. At 8 years postoperative, IOP reduced by 26% from 19.2 ± 3.9 mmHg preoperatively to 14.2 ± 2.4 mmHg (P < 0.001), 91.1% of eyes achieved IOP ≤ 18 mmHg (vs. 51.6% preoperatively), 69.6% of eyes achieved IOP ≤ 15 mmHg (vs. 14.5% preoperatively), and 25% of eyes achieved IOP ≤ 12 mmHg (vs. 1.6% preoperatively). Medication use decreased by 17.9% from 2.8 ± 1.1 preoperatively to 2.3 ± 1.2 (P = 0.018). Surgical success was 90%, as six eyes underwent subsequent glaucoma surgeries. Safety measures of BCVA, CDR, RNFL thickness and GC-IPL thickness remained stable through 8 years postoperative. VF-MD remained stable until postoperative year 5 and subsequently progressed according to the natural history of glaucomatous disease. Conclusions Implantation of two iStents with concomitant cataract surgery is an effective and safe treatment option for surgery-naïve POAG eyes, evidenced by significant IOP and medication reductions, reasonable surgical success, and favorable safety outcomes, throughout the 8-year follow-up. Our data additionally supports the efficacy of this combined procedure in stabilizing or slowing disease progression. Supplementary Information The online version contains supplementary material available at 10.1186/s40662-021-00263-1.
Collapse
Affiliation(s)
- Ali Salimi
- Department of Ophthalmology, Faculty of Medicine, McGill University, Montreal, QC, Canada.,Montreal Glaucoma Institute, Montreal, QC, Canada
| | - Harrison Watt
- Faculty of Medicine, McGill University, Montreal, QC, Canada
| | - Paul Harasymowycz
- Montreal Glaucoma Institute, Montreal, QC, Canada. .,Department of Ophthalmology, University of Montreal, 4135 de Rouen, Montreal, QC, H1V1G5, Canada.
| |
Collapse
|
16
|
Role of minimally invasive glaucoma surgery in the management of chronic open-angle glaucoma. Sci Rep 2021; 11:21432. [PMID: 34728652 PMCID: PMC8563755 DOI: 10.1038/s41598-021-00808-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Accepted: 10/18/2021] [Indexed: 11/09/2022] Open
Abstract
To compare the safety and efficacy of phacoemulsification combined with ab-interno trabeculectomy (Trabectome) and phacoemulsification combined with I-Stent inject in patients with medically uncontrolled primary open-angle glaucoma (POAG). A retrospective comparative case series. 70 eyes of 66 patients completed 2 years follow up after these treatments performed in 2017–2018. 35 eyes of 33 patients underwent combined Phaco-Trabectome (PT); and 35 eyes of 33 patients underwent combined Phaco-I-Stent inject (Pi). Patient demographics and preoperative characteristics are comparable. A 20% drop in IOP was achieved in 27 eyes (77.14%) in PT group and 28 eyes (80%) in Pi group (p = 0.77). Success rate (target IOP achieved and maintained for 2 years) in advance glaucoma was 25% in PT group and 30.7% in Pi group (p = 0.90). In mild to moderate glaucoma, success rate was 85.71% in PT group and 90% in Pi group (p = 0.67). There was no significant difference between two groups with regards to mean reduction in glaucoma medications and complication rates. Trabectome and I-Stent combined with phacoemulsification are equally efficacious and safe for treating patients with medically uncontrolled mild and moderate primary open-angle glaucoma (POAG). However, they are not an effective treatment for patients with advanced glaucoma.
Collapse
|
17
|
Al Habash A, Otaif W. Surgical Outcomes of Combined 2nd-Generation Trabecular Microbypass (iStent Inject) and Cataract Surgery for the Treatment of Primary Open-Angle Glaucoma in the Saudi Population. Ophthalmol Ther 2021; 10:923-933. [PMID: 34351592 PMCID: PMC8589900 DOI: 10.1007/s40123-021-00380-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 07/19/2021] [Indexed: 11/03/2022] Open
Abstract
INTRODUCTION To investigate the 24-month efficacy and safety of iStent inject trabecular microbypass system implantation combined with phacoemulsification in subjects with primary open-angle glaucoma (POAG) and concomitant cataract. METHODS This prospective, uncontrolled, interventional case series included 36 eyes (29 subjects) with POAG of mild to moderate severity and coexisting cataract that underwent combined phacoemulsification and implantation of a second-generation trabecular microbypass stent (iStent inject®). Main outcome measures involved mean intraocular pressure (IOP), number of antiglaucoma medications, and proportional analysis of eyes with IOP ≤ 18 mmHg or ≤ 15 mmHg, or with 0 or ≥ 2 glaucoma medications. Secondary outcome measures involved the cup-to-disc ratio, corrected distance visual acuity (CDVA), and adverse issues. RESULTS In 36 eyes, the mean IOP at baseline was 18.28 ± 2.87 mmHg, which decreased to 14.24 ± 1.36 (22.1%) and 14.46 ± 1.56 mmHg (20.9%) at 18 and 24 months, respectively (p < 0.001). At the last follow-up, 100% of eyes had an IOP ≤ 18 mmHg (vs. 50% preoperatively), and 75.7% of eyes had an IOP ≤ 15 mmHg (vs. 16.7% preoperatively); 58.3% of eyes achieved ≥ 20% IOP reduction from preoperative status. At baseline, eyes were treated with a mean of 2.35 ± 1.18 medications, which was reduced to 0.80 ± 1.04 (66% reduction) and 0.69 ± 0.95 medications (70.6% reduction) at 18 and 24 months, respectively (p < 0.001). At the last follow-up, 54.1% of eyes were medication-free (vs. 0% preoperatively) and 24.3% of eyes were treated with ≥ 2 medications (vs. 64.9% preoperatively). This combined procedure demonstrated an excellent safety profile with no reported intraoperative complications or adverse events; CDVA was maintained throughout the entire follow-up period. CONCLUSIONS This real-world series demonstrated that iStent inject device implantation at the time of phacoemulsification is a safe and effective method to decrease IOP and the necessity for antiglaucoma medications in patients with mild-to-moderate POAG and cataract; no associated vision-threatening complications were noted.
Collapse
Affiliation(s)
- Ahmed Al Habash
- Department of Ophthalmology, King Fahd Hospital of the University, College of Medicine, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
| | - Wael Otaif
- Department of Ophthalmology, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
18
|
Mikula E, Holland G, Srass H, Suarez C, Jester JV, Juhasz T. Intraocular Pressure Reduction by Femtosecond Laser Created Trabecular Channels in Perfused Human Anterior Segments. Transl Vis Sci Technol 2021; 10:22. [PMID: 34406341 PMCID: PMC8374973 DOI: 10.1167/tvst.10.9.22] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose This study investigated the initial feasibility of using femtosecond laser trabeculotomy (FLT) to create open channels through the trabecular meshwork into Schlemm's canal to lower intraocular pressure (IOP) in a perfused anterior segment model. Methods Human anterior segments (12 eyes) were assigned to either treatment (n = 6) or sham treatment (n = 6) groups. Both groups were perfused until a baseline IOP was recorded upon which a direct FLT treatment or a sham treatment was administered. IOP was recorded before and after the treatment. Spectral domain optical coherence tomography and second harmonic generation imaging we used to investigate the FLT channels. Results In the FLT group, there was a significant mean decrease in the IOP of 22% compared with the pre-FLT IOP (7.13 ± 2.95 mm Hg to 5.34 ± 1.62 mm Hg; P < 0.05). In the control group, the post-sham IOP remained relatively unchanged compared with the pre-sham IOP (6.39 ± 3.69 mm Hg to 6.67 ± 4.12 mm Hg). Conclusions The results of this study indicate that FLT treatment can significantly decrease the IOP in a perfusion model and may provide a potential noninvasive treatment option for primary open angle glaucoma. Translational Relevance Investigating the use of femtosecond lasers for photodisrupting the trabecular meshwork can lead to a clinically relevant alternative to current glaucoma procedures.
Collapse
Affiliation(s)
- Eric Mikula
- Department of Ophthalmology, University of California, Irvine, Irvine, CA, USA.,ViaLase Inc., Aliso Viejo, CA, USA
| | | | | | | | - James V Jester
- Department of Ophthalmology, University of California, Irvine, Irvine, CA, USA.,Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, USA
| | - Tibor Juhasz
- Department of Ophthalmology, University of California, Irvine, Irvine, CA, USA.,ViaLase Inc., Aliso Viejo, CA, USA.,Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, USA
| |
Collapse
|
19
|
Abstract
Micro- or minimally invasive glaucoma surgeries (MIGS) have been the latest addition to the glaucoma surgical treatment paradigm. This term refers not to a single surgery, but rather to a group of distinct procedures and devices that aim to decrease intraocular pressure. Broadly, MIGS can be categorized into surgeries that increase the trabecular outflow [Trabectome, iStent (first and second generations), Hydrus microstent, Kahook Dual Blade and gonioscopy-assisted transluminal trabeculotomy], surgeries that increase suprachoroidal outflow (Cypass microstent and iStent Supra), and conjunctival bleb-forming procedures (Xen gel stent and InnFocus microshunt). Compared to traditional glaucoma surgeries, such as trabeculectomy and glaucoma drainage device implantation (Ahmed, Baerveldt, and Molteno valves), MIGS are touted to have less severe complications and shorter surgical time. MIGS represent an evolving field, and the efficacy and complications of each procedure should be considered independently, giving more importance to high-quality and longer-term studies.
Collapse
Affiliation(s)
- David J Mathew
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario M5T 2S8, Canada;
| | - Yvonne M Buys
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario M5T 2S8, Canada;
| |
Collapse
|
20
|
Teus MA, Belda JI, Lavín C, GarcÃa-Feijoà J, Falvey H, Buseghin G, Soler M, Appierto M. Cost-effectiveness analysis of iStent Inject® implantation during cataract surgery compared to cataract surgery alone for mild to moderate open-angle glaucoma patients in Spain. EXPERT REVIEW OF OPHTHALMOLOGY 2021. [DOI: 10.1080/17469899.2021.1939685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Miguel A Teus
- Ophtalmology Department, Hospital Universitario Príncipe De Asturias, University of Alcalá, Madrid, Spain
| | - Jose I Belda
- Ophthalmology Department, Hospital Universitario Torrevieja, Alicante, Spain
| | - Cosme Lavín
- Ophthalmology Department, Hospital Universitario La Paz, Madrid, Spain
| | - Julián GarcÃa-FeijoÃ
- Ophthalmology Unit, Hospital Clínico San Carlos, Instituto De Investigación Sanitaria Del Hospital Clínico San Carlos (Idissc), OFTARED, Madrid, Spain
| | - H Falvey
- Health Economics and Market Access Department, Glaukos, San Clemente, California, United States
| | - Giorgio Buseghin
- Health Economics and Market Access Department, Glaukos, San Clemente, California, United States
| | - María Soler
- Health Economics Department, Outcomes’10 S.L.U, Castellón De La Plana, Spain
| | - Marilena Appierto
- Health Economics Department, Outcomes’10 S.L.U, Castellón De La Plana, Spain
| |
Collapse
|
21
|
Schlenker M, Kansal V. How Mean Intraocular Pressures Are Failing Patients. Ophthalmol Glaucoma 2021; 4:553-557. [PMID: 34092547 DOI: 10.1016/j.ogla.2021.04.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 03/25/2021] [Accepted: 04/21/2021] [Indexed: 11/18/2022]
|
22
|
In-vivo imaging of the conventional aqueous outflow system. Curr Opin Ophthalmol 2021; 32:275-279. [PMID: 33653980 DOI: 10.1097/icu.0000000000000751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
PURPOSE OF REVIEW The aim of this study was to provide a comprehensive summary of in-vivo imaging techniques of the aqueous outflow system and discuss its role in improving our understanding of glaucoma pathogenesis and management. RECENT FINDINGS Our understanding of the aqueous outflow system is largely derived from ex-vivo studies. Recent innovations in imaging technology and techniques enable in-vivo evaluation of the conventional outflow system in real-time. Optical coherence tomography allows for noninvasive, high-resolution, volumetric imaging of ocular tissues. Dynamic structural changes have been observed at the trabecular meshwork and Schlemm's canal. In parallel, aqueous angiography using injected tracers show a similar dynamism with variable and pulsatile flow signals. SUMMARY In-vivo imaging enable real-time evaluation of the conventional aqueous outflow pathway. This emerging field shows great promise to expand our understanding of the pathogenesis and treatment of glaucoma.
Collapse
|
23
|
Factors Associated With Unqualified Success After Trabecular Bypass Surgery: A Case-control Study. J Glaucoma 2021; 29:1082-1087. [PMID: 32769734 DOI: 10.1097/ijg.0000000000001626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PRECIS An older age, a low number of baseline glaucoma medications, an early glaucoma stage, lower intraocular pressure (IOP) values during the first postoperative month, and combined surgery are possible predictors of unqualified success after a trabecular by-pass microinvasive glaucoma surgery (MIGS) procedure. PURPOSE The purpose of this study was to identify the potential predictors of unqualified success (IOP<18 mm Hg with no glaucoma medication) after trabecular by-pass MIGS. MATERIALS AND METHODS We designed a case-control study using logistic regression modeling that included all trabecular by-pass surgeries with at least 3 months of follow-up, performed at a single center from June 2017 to December 2019. Eyes that achieved an endpoint of unqualified success (dependent variable) were considered cases. All other eyes were used as the controls. Cases and controls were paired by sex and postoperative time. We tested the following independent variables: age, race, laterality (right eye or left eye), glaucoma stage, type of surgery (combined or stand-alone), type of trabecular bypass, intraoperative complications, baseline number of medications, baseline IOP, and postoperative IOP on days 1, 15, and 30. Additional analysis using IOP <15 mm Hg as a threshold and including eyes with at least 12 months of follow-up were performed. RESULTS One hundred ninety-four eyes were included in the analysis. We observed complete success in 56.7% of eyes. The mean follow-up time for the entire population was 12.3±6.8 months. All variables were considered in the first step of the modeling process; however, only age, day-15 IOP, day-30 IOP, baseline number of medications, glaucoma stage, and type of surgery remained until the completion of our model, with adequate significance (P<0.05). The additional analysis confirmed our results. CONCLUSION We identified that an older age, a low number of baseline glaucoma medications, an early glaucoma stage, lower IOP values during the first postoperative month, and combined surgery were associated with a higher chance of unqualified success at 12 months after a trabecular by-pass MIGS procedure.
Collapse
|
24
|
Standalone iStent Trabecular Micro-bypass Glaucoma Surgery: A Systematic Review and Meta-Analysis. J Glaucoma 2021; 30:606-620. [PMID: 33596009 DOI: 10.1097/ijg.0000000000001805] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 01/07/2021] [Indexed: 11/25/2022]
Abstract
PRECIS Standalone trabecular micro-bypass glaucoma surgery with the iStent devices is associated with clinically relevant reductions in intraocular pressure (IOP) sustained over a reasonably long-term while simultaneously reducing medication burden and a relatively favorable safety profile. PURPOSE While there is a relatively large body of evidence supporting the implantation of the iStent trabecular micro-bypass devices during phacoemulsification in patients with open-angle glaucoma (OAG), its efficacy as a standalone procedure has been less widely reported. The aims of this study were to systematically identify and quantitatively evaluate the efficacy of iStent devices (iStent and iStent inject) when performed independently of cataract surgery in patients with OAG. METHODS A systematic review of the literature was undertaken in August 2019 to identify studies of standalone trabecular micro-bypass glaucoma surgery with iStent devices in patients with OAG. All randomized trials were considered and nonrandomized studies that included at least 6 months of follow-up or more than 10 eyes. Key efficacy analyses included postoperative IOP and medication use, which were used to evaluate weighted mean differences from baseline, and the proportion of eyes free of ocular medication. Postoperative adverse events were descriptively summarized. RESULTS A total of 13 studies were identified including 4 randomized controlled trials and 9 nonrandomized or single-arm studies providing data for 778 eyes. In eyes implanted with iStent devices, a weighted mean IOP reduction of 31.1% was observed at 6 to 12 months. In studies reporting longer-term outcomes (36 to 48 mo or 60 mo), the weighted mean IOP reduction was 30.4% and 32.9%, respectively. The pooled weighted mean reduction in IOP from baseline across all studies at 6 to 12 months and 36 to 60 months poststent implantation was 7.01 mm Hg (95% confidence interval: 5.91, 8.11) and 6.59 mm Hg (95% confidence interval: 5.55, 7.63), respectively. Medication burden was reduced by ~1.0 medication at 6 to 18 months and 1.2 medications at 36 to 60 months. Adverse events reported in more than 5% of participants were progression of pre-existing cataract/cataract surgery and loss of best-corrected visual acuity but these rates were no different to those reported in comparator medical therapy study arms. CONCLUSIONS The results from these studies support the independent effect of the iStent trabecular bypass devices on IOP and medication burden over a duration of follow-up of up to 5 years.
Collapse
|
25
|
Kim SJ, Moon SW, Lee JW. One-year Result of Trabeculectomy Following a Failed Trabecular Micro-bypass Stent. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2021. [DOI: 10.3341/jkos.2021.62.2.243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
26
|
Arnljots TS, Economou MA. Kahook Dual Blade Goniotomy vs iStent inject: Long-Term Results in Patients with Open-Angle Glaucoma. Clin Ophthalmol 2021; 15:541-550. [PMID: 33603332 PMCID: PMC7884935 DOI: 10.2147/opth.s284687] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 12/21/2020] [Indexed: 12/05/2022] Open
Abstract
Purpose Efficacy and safety evaluation of Kahook Dual Blade (KDB) goniotomy vs iStent inject implantation. Materials and Methods Retrospective study in patients that underwent goniotomy with KDB or iStent inject implantation, stand-alone or combined with cataract surgery. Main outcome parameters were intraocular pressure (IOP), number of glaucoma medications, proportion of eyes achieving >20% IOP reduction and number of eyes with postoperative IOP <19 mmHg at last follow-up. Results A total of 29 patients (30 eyes) were included in the iStent inject group and 30 patients (32 eyes) in the KDB group. Mean follow-ups were 20.9±6.5 (KDB-alone) to 29.5±7.6 (phaco-iStent inject) months. Pre- and post-operative IOPs were 22.2±5.8 mmHg and 15.9±4.3 mmHg (P=0.004) in the KDB-alone, 24.2±6.8 mmHg and 16.2±6.7 mmHg (P=0.001) in the phaco-KDB, 20.6±5.4 mmHg and 20.9±6.8 mmHg (P=0.598) in the iStent inject-alone as well as 20.9±5.5 mmHg and 15.6±3.4 mmHg (P=0.003) in the phaco-iStent inject subgroups. No major complications occurred. Conclusion All KDB and iStent subgroups except the stand-alone iStent inject subgroup showed a clinically significant IOP-lowering effect as a stand-alone procedure or combined with cataract surgery. Goniotomy with KDB in this setting seems to offer an advantageous IOP reduction compared to iStent inject.
Collapse
Affiliation(s)
| | - Mario A Economou
- Division of Ophthalmology and Vision, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Ophthalmology, Sophiahemmet Hospital, Stockholm, Sweden
| |
Collapse
|
27
|
The Effects of Trabecular Bypass Surgery on Conventional Aqueous Outflow, Visualized by Hemoglobin Video Imaging. J Glaucoma 2020; 29:656-665. [PMID: 32773669 DOI: 10.1097/ijg.0000000000001561] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PRECIS Hemoglobin Video Imaging (HVI) provides a noninvasive method to quantify aqueous outflow (AO) perioperatively. Trabecular bypass surgery (TBS) is able to improve, and in some cases re-establish, conventional AO. PURPOSE The purpose of this study was to use HVI to illustrate and quantify effects of TBS on AO through the episcleral venous system. DESIGN This is a prospective observational cohort study. PARTICIPANTS Patients were recruited from Sydney Eye Hospital, Australia. The study included 29 eyes from 25 patients, 15 with glaucoma and 14 normal controls. TBS (iStent Inject) was performed on 14 glaucomatous eyes (9 combined phacoemulsification/TBS and 5 standalone TBS). Cataract surgery alone was performed on the remaining eye from the glaucoma group and 2 eyes from the control group. METHODS We used HVI, a novel clinic-based tool, to visualize and quantify AO perioperatively during routine follow-up to 6 months. Angiographic blood flow patterns were observed within prominent aqueous veins on the nasal and temporal ocular surface. Aqueous column cross-section area (AqCA) was compared before and after surgery. MAIN OUTCOME MEASURES AqCA, number of aqueous veins, intraocular pressure (IOP) before and after surgery, and number of IOP-lowering medications. RESULTS Patients with glaucoma had reduced AqCA compared with normal controls (P=0.00001). TBS increased AqCA in 13 eyes at 1 month (n=14; P<0.002), suggesting improved AO. This effect was maintained at 6 months in 7 eyes (n=9, P≤0.05). All patients with unrecordable AO before surgery (n=3; 2 standalone TBS, 1 combined cataract/TBS) established measurable flow after TBS. IOP and/or medication burden became reduced in every patient undergoing TBS. Cataract surgery alone (n=3) increased AqCA in nasal and temporal vessels at 4 weeks after surgery. CONCLUSIONS HVI provides a safe method for detecting and monitoring AO perioperatively in an outpatient setting. Improvement of AO into the episcleral venous system is expected after TBS and can be visualized with HVI. TBS is able to improve, and in some cases re-establish, conventional AO. Cataract surgery may augment this. Some aqueous veins were first seen after TBS and these patients had unstable postoperative IOP control, which possibly suggests reorganization of aqueous homeostatic mechanisms. HVI may confirm adequacy of surgery during short-term follow-up, but further work is required to assess the potential of HVI to predict surgical outcomes and assist with personalized treatment decisions.
Collapse
|
28
|
Grierson I, Minckler D, Rippy MK, Marshall AJ, Collignon N, Bianco J, Detry B, Johnstone MA. A novel suprachoroidal microinvasive glaucoma implant: in vivo biocompatibility and biointegration. BMC Biomed Eng 2020; 2:10. [PMID: 33073174 PMCID: PMC7556975 DOI: 10.1186/s42490-020-00045-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 09/22/2020] [Indexed: 12/29/2022] Open
Abstract
Background A major challenge for any glaucoma implant is their ability to provide long-term intraocular pressure lowering efficacy. The formation of a low-permeability fibrous capsule around the device often leads to obstructed drainage channels, which may impair the drainage function of devices. These foreign body-related limitations point to the need to develop biologically inert biomaterials to improve performance in reaching long-term intraocular pressure reduction. The aim of this study was to evaluate in vivo (in rabbits) the ocular biocompatibility and tissue integration of a novel suprachoroidal microinvasive glaucoma implant, MINIject™ (iSTAR Medical, Wavre, Belgium). Results In two rabbit studies, no biocompatibility issue was induced by the suprachoroidal, ab-externo implantation of the MINIject™ device. Clinical evaluation throughout the 6 post-operative months between the sham and test groups were similar, suggesting most reactions were related to the ab-externo surgical technique used for rabbits, rather than the implant material itself. Histological analysis of ocular tissues at post-operative months 1, 3 and 6 revealed that the implant was well-tolerated and induced only minimal fibroplasia and thus minimal encapsulation around the implant. The microporous structure of the device became rapidly colonized by cells, mostly by macrophages through cell migration, which do not, by their nature, impede the flow of aqueous humor through the device. Time-course analysis showed that once established, pore colonization was stable over time. No fibrosis nor dense connective tissue development were observed within any implant at any time point. The presence of pore colonization may be the process by which encapsulation around the implant is minimized, thus preserving the permeability of the surrounding tissues. No degradation nor structural changes of the implant occurred during the course of both studies. Conclusions The novel MINIject™ microinvasive glaucoma implant was well-tolerated in ocular tissues of rabbits, with observance of biointegration, and no biocompatibility issues. Minimal fibrous encapsulation and stable cellular pore colonization provided evidence of preserved drainage properties over time, suggesting that the implant may produce a long-term ability to enhance aqueous outflow.
Collapse
Affiliation(s)
- Ian Grierson
- Department of Eye and Vision Science, Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, UK
| | - Don Minckler
- University of California, Irvine School of Medicine, Irvine, CA USA
| | | | | | - Nathalie Collignon
- Department of Ophthalmology, Centre Hospitalier Universitaire of Liège, Liège, Belgium
| | | | - Benoit Detry
- iSTAR Medical SA, Avenue Sabin 6, 1300 Wavre, Belgium
| | - Murray A Johnstone
- Department of Ophthalmology, University of Washington, Seattle, Washington USA
| |
Collapse
|
29
|
Nichani P, Popovic MM, Schlenker MB, Park J, Ahmed IIK. Microinvasive glaucoma surgery: A review of 3476 eyes. Surv Ophthalmol 2020; 66:714-742. [PMID: 32998003 DOI: 10.1016/j.survophthal.2020.09.005] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Revised: 09/20/2020] [Accepted: 09/21/2020] [Indexed: 02/06/2023]
Abstract
Microinvasive glaucoma surgery (MIGS) is a potentially safer and more efficacious method studied in patients with mild-to-moderate open-angle glaucoma requiring less invasive treatment goals; however, the literature on MIGS must be thoroughly evaluated. We conducted a review of MIGS by searching MEDLINE, EMBASE, and Cochrane CENTRAL. Primary efficacy indicators were reductions in intraocular pressure and topical medication use postoperatively. While all comparative randomized controlled trials assessing MIGS in English peer-reviewed journals were included, only observational studies with a target follow-up of at least one year and a high priority score were analyzed, resulting in a total of 3476 eyes across 20 trials. The mean age was 69.5 ± 2.9 years, 53.7% were female, and 77.4% were Caucasian. One study had last follow-up at less than one year, fifteen studies had follow-up extending 1-2 years, and four had longer than two years of follow-up. A pattern of more significant intraocular pressure and medication reduction was observed in patients who underwent MIGS (n = 2170) relative to control (n = 1306) interventions. iStent had the most literature supporting its efficacy, followed by Hydrus. The most common adverse events after MIGS implantation included stent obstruction, inflammation, and subsequent surgical intervention. Surgical complication rates and efficacy are favorable after MIGS. This review helps to consolidate the high-quality evidence that exists for various MIGS procedures and to identify gaps where further research is needed.
Collapse
Affiliation(s)
- Prem Nichani
- Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Marko M Popovic
- Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada; Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada
| | - Matthew B Schlenker
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada; Kensington Eye Institute, Toronto, Ontario, Canada
| | - Jeff Park
- Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Iqbal Ike K Ahmed
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada; Prism Eye Institute, Mississauga, Ontario, Canada; Department of Ophthalmology, Trillium Health Partners, Mississauga, Ontario, Canada.
| |
Collapse
|
30
|
Trabecular microbypass stent implantation in pseudoexfoliative glaucoma: long-term results. J Cataract Refract Surg 2020; 46:1284-1289. [DOI: 10.1097/j.jcrs.0000000000000243] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
31
|
Kim HJ, Lim SH. Clinical outcomes of trabecular microbypass stent (iStent) implantation in medically controlled open-angle glaucoma in the Korean population. Medicine (Baltimore) 2020; 99:e21729. [PMID: 32872056 PMCID: PMC7437814 DOI: 10.1097/md.0000000000021729] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
To evaluate the safety and efficacy [intraocular pressure (IOP)-lowering effect and medication use] of a single trabecular microbypass stent (iStent; Glaukos Corp, San Clemente, CA) for medically controlled open-angle glaucoma.This retrospective case series included 42 eyes of 34 patients with medically controlled open-angle glaucoma with IOP less than 21 mm Hg. Clinical outcomes analyzed were IOP, medication use, corrected distance visual acuity (CDVA), and surgical complications. Surgical success was defined according to 4 criteria: IOP < 21 mm Hg without medication; IOP < 18 mm Hg without medication; IOP < 15 mm Hg without medications; and IOP < 18 mm Hg with or without medication. Patients were followed for a minimum of 6 months postoperatively.Mean IOP was reduced from 15.8 ± 2.8 mm Hg to 14.5 ± 2.8 mm Hg (P < .001), while mean number of medications decreased from 2.2 ± 1.2 to 0.8 ± 1.1 at final visit (P < .001). Surgical success rates were 78.6%, 61.9%, 57.1%, and 97.6% at 6 months and 78.6%, 59.5%, 52.4%, and 95.2% at final visits according to criteria A, B, C, and D. Meanwhile, 59.5% of patients were medication-free at their final visit. The relative risk of surgical failure by Criteria B and C was 4.337 (95% confidence interval: 1.799-10.454) and 3.717 (95% confidence interval: 1.516-9.116) times greater in the higher-medication group (3 or more preoperative medications), respectively. CDVA was significantly improved from 0.41 ± 0.10 to 0.09 ± 0.07 LogMAR in the combined phacoemulsification and iStent implantation group (P < .001). There was no case whose vision was threatened (vision loss of 2 or more lines) or who showed severe complications after surgery.Single trabecular microbypass stent implantation was effective in reducing IOP and medication usage in patients with open-angle glaucoma with a low preoperative IOP. Our results imply that it is more difficult to achieve low target IOP control in eyes with higher numbers of preoperative medications.
Collapse
Affiliation(s)
- Hee Jun Kim
- Good Doctors Eye Hospital, Ulsan
- Department of Ophthalmology, Yeungnam University College of Medicine, Daegu
| | - Su-Ho Lim
- Department of Ophthalmology, Yeungnam University College of Medicine, Daegu
- Department of Ophthalmology, Daegu Veterans Health Service Medical Center, Daegu, Republic of Korea
| |
Collapse
|
32
|
Saheb H, Donnenfeld ED, Solomon KD, Voskanyan L, Chang DF, Samuelson TW, Ahmed IIK, Katz LJ. Five-Year Outcomes Prospective Study of Two First-Generation Trabecular Micro-Bypass Stents (iStent®) in Open-Angle Glaucoma. Curr Eye Res 2020; 46:224-231. [PMID: 32715828 DOI: 10.1080/02713683.2020.1795881] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE To assess 5-year effectiveness and safety of 2 iStent® trabecular micro-bypass stents in eyes with open-angle glaucoma (OAG) not controlled on 1 medication. MATERIALS AND METHODS This prospective, interventional, single-arm, multi-surgeon study (NCT #1252862, clinicaltrials.gov) enrolled eyes with OAG, preoperative intraocular pressure (IOP) of 18-30 mmHg on 1 ocular hypotensive medication, and 22-38 mmHg after medication washout. Eyes underwent standalone implantation of 2 iStent devices and were followed through 60 months postoperatively. Efficacy was quantified by mean diurnal IOP and medication usage. Efficacy endpoints included the proportion of eyes with ≥20% IOP reduction versus baseline unmedicated IOP (primary efficacy), and the proportion of eyes with IOP ≤18 mmHg (secondary efficacy) without medication or secondary glaucoma surgery. Safety parameters included visual acuity, cup-to-disc ratio, visual field, and complications and adverse events. RESULTS Preoperative mean IOP on 1 medication was 20.6 ± 2.0 mmHg and post-washout unmedicated IOP was 24.1 ± 1.4 mmHg (n = 39). At 5 years postoperative, medication-free mean diurnal IOP reduced to 14.5 ± 2.2 mmHg, constituting a 40% decrease versus preoperative washed-out IOP (p < .0001). In addition, this 5-year medication-free IOP constituted a 30% decrease versus preoperative IOP on 1 medication (p < .0001). At Month 60, 89.7% (26/29) of eyes achieved the primary efficacy endpoint of ≥20% IOP reduction versus baseline unmedicated IOP, and 86.2% (25/29) of eyes achieved the secondary efficacy endpoint of IOP ≤18 mmHg, without medication or secondary glaucoma surgery. Throughout follow-up, 89.7-91.3% of eyes were on no medications. Favorable safety included no secondary glaucoma surgeries, minimal adverse events, and stable visual acuity, cup-to-disc ratio, and visual fields through 5 years postoperative. CONCLUSIONS This prospective interventional study demonstrates persistent 5-year reductions in IOP and freedom from medications, together with favorable safety, following implantation of 2 first-generation trabecular micro-bypass stents in eyes with OAG on 1 preoperative medication.
Collapse
Affiliation(s)
- Hady Saheb
- Department of Ophthalmology, McGill University , Montreal, Quebec, Canada
| | - Eric D Donnenfeld
- Ophthalmic Consultants of Long Island , Rockville Centre, New York, USA
| | - Kerry D Solomon
- Carolina Eyecare Physicians , Mt Pleasant, South Carolina, USA
| | | | | | | | - Iqbal Ike K Ahmed
- Department of Ophthalmology, University of Toronto , Toronto, Ontario, Canada
| | - L Jay Katz
- Department of Ophthalmology, Wills Eye Hospital, Jefferson Medical College , Philadelphia, Pennsylvania, USA
| |
Collapse
|
33
|
June consultation #2. J Cataract Refract Surg 2020; 46:922-923. [DOI: 10.1097/01.j.jcrs.0000681820.19821.1a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
34
|
Use of iStent as a Standalone Operation in Patients with Open-Angle Glaucoma. J Ophthalmol 2020; 2020:8754730. [PMID: 32566270 PMCID: PMC7267876 DOI: 10.1155/2020/8754730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 05/03/2020] [Accepted: 05/12/2020] [Indexed: 12/04/2022] Open
Abstract
Purpose The iStent provides a direct pathway for aqueous outflow from the anterior chamber to Schlemm's canal in patients with open-angle glaucoma (OAG). We performed a meta-analysis to evaluate the effectiveness of iStent as a standalone operation in patients with OAG in reducing the intraocular pressure (IOP) and the number of topical glaucoma medications. Methods We searched various databases between January 1, 2000, and September 30, 2019, and included only peer-reviewed, prospective, or retrospective clinical studies in our analyses. Details regarding the IOP and the number of medications at baseline and end point were recorded from each study. Standardized mean differences (SMDs) of IOP and medication numbers were calculated. Furthermore, the success rate (the proportion of IOP ≤18 mmHg and IOP reduction ≥20% at end point) and the complication rate were also summarized. Finally, a subgroup analysis was done based on the iStent generation (first and second), follow-up duration (≤6, 6–18, 18–36, and >36 months), and iStent number (one, two, and three). The outcome measures were aggregated SMDs computed from each study. Results A total of 17 studies with 978 eyes were included in this analysis. All studies demonstrated a reduction in IOP after iStent implantation. Aggregated SMDs of IOP revealed a significant reduction (SMD = −2.64, 95% confidence interval (CI): −3.21 to −2.07). The success rate was significantly good, and most of the complication rates were low. The number of medications was also significantly reduced (SMD = −1.71, 95% CI: −2.18 to −1.24). The subgroup analysis revealed a reduction in IOP and medication burden in each category of iStent generation, follow-up duration of up to 42 months, and iStent numbers. Conclusion Use of iStent as a standalone procedure does reduce the IOP and the number of glaucoma medications. The benefit of iStent lasts for at least 42 months.
Collapse
|
35
|
iStent inject trabecular microbypass stent implantation with cataract extraction in open-angle glaucoma: early clinical experience. EYE AND VISION 2020; 7:28. [PMID: 32490028 PMCID: PMC7247162 DOI: 10.1186/s40662-020-00194-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Accepted: 04/28/2020] [Indexed: 12/18/2022]
Abstract
Background Retrospective, consecutive case series to evaluate the implantation of two second-generation trabecular microbypass stents in combination with cataract surgery in a real-world, clinical setting. Methods The series included 56 eyes implanted with the iStent inject device with phacoemulsification. The series consisted of eyes with primary open-angle glaucoma (n = 52) and pseudoexfoliative glaucoma (n = 4). Primary outcome measures included intraocular pressure (IOP) and number of glaucoma medications. Safety outcomes included the need for secondary surgical intervention and the incidence of IOP spikes ≥10 mmHg and ≥ 15 mmHg. Results IOP was reduced by 21% to 14.7 ± 2.9 mmHg (p < 0.01) at 6 months postoperative from 18.7 ± 5.8 mmHg at baseline. Preoperatively, the mean number of glaucoma medications was 1.5 ± 0.9 and reduced by 39% to 0.9 ± 1.2 (p < 0.01) at 6 months. At 6 months, 68% of eyes had an IOP ≤15 mmHg, increased from 30% at baseline. 55% of eyes were medication-free at 6 months, up from 18% at baseline. There were no severe postoperative complications. No eyes underwent an additional glaucoma procedure. Conclusions Implantation of the iStent inject device with concomitant cataract surgery effectively provides a sustained reduction in IOP with a markedly improved medication burden out to 6 months postoperative. The safety profile is excellent.
Collapse
|
36
|
Berdahl J, Voskanyan L, Myers JS, Katz LJ, Samuelson TW. iStent
inject trabecular micro‐bypass stents with topical prostaglandin as standalone treatment for open‐angle glaucoma: 4‐year outcomes. Clin Exp Ophthalmol 2020; 48:767-774. [DOI: 10.1111/ceo.13763] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 04/01/2020] [Accepted: 04/09/2020] [Indexed: 01/22/2023]
Affiliation(s)
- John Berdahl
- Vance Thompson Vision Sioux Falls South Dakota USA
| | | | - Jonathan S. Myers
- Wills Eye HospitalJefferson Medical College Philadelphia Pennsylvania USA
| | - L. Jay Katz
- Wills Eye HospitalJefferson Medical College Philadelphia Pennsylvania USA
- Glaukos Corporation San Clemente California USA
| | | |
Collapse
|
37
|
Gillmann K, Mansouri K. Minimally Invasive Glaucoma Surgery: Where Is the Evidence? Asia Pac J Ophthalmol (Phila) 2020; 9:203-214. [PMID: 32501895 PMCID: PMC7299223 DOI: 10.1097/apo.0000000000000294] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 04/04/2020] [Indexed: 12/12/2022] Open
Abstract
PURPOSE The last decade has witnessed an unprecedented growth in glaucoma treatment options through the introduction of minimally invasive glaucoma surgeries (MIGS). The aim of the present review is to provide an understanding of the currently available MIGS and to examine what data are currently available to guide treatment choice. DESIGN Meta-analysis and systematic review of randomized and non-randomized control trials. METHODS Out of 2567 articles identified, a total of 77 articles were retained for analysis, including 28 comparative studies and 12 randomized control trials. Overall, 7570 eyes were included. When data permitted, the weighted mean difference in intraocular pressure reduction was calculated for comparison purposes. RESULTS Weighted mean intraocular pressure reductions from all analyzed studies were: 15.3% (iStent), 29.1% (iStent inject), 36.2% (ab interno canaloplasty), 34.4% (Hydrus), 36.5% (gonioscopically-assisted transluminal trabeculotomy), 24.0% (trabectome), 25.1% (Kahook dual blade), 30.2% (Cypass), 38.8% (XEN), and 50.0% (Preserflo). CONCLUSIONS One of the advantages of the heterogenous range of available MIGS options is the chance to tailor therapy in an individualized manner. However, high-quality data are required to make this choice more than an educated guess. Overall, this review confirms the efficiency of assessed MIGS compared with standalone phacoemulsification, but it highlights that only few studies compare different MIGS techniques and even fewer assess MIGS against criterion standard treatments. Current evidence, while non-negligible, is mostly limited to heterogenous nonrandomized studies and uncontrolled retrospective comparisons, with few quality randomized control trials. We suggest that future research should be comparative and include relevant comparators, standardized to report key outcome features, long-term to assess sustainability and late complications, and ideally randomized.
Collapse
Affiliation(s)
- Kevin Gillmann
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
| | - Kaweh Mansouri
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
- Department of Ophthalmology, University of Colorado School of Medicine, Denver, CO, USA
| |
Collapse
|
38
|
Comparison of Using One Trabecular Microbypass Stent versus Two during Cataract Surgery at Two Sites: One-Year Follow-Up. BIOMED RESEARCH INTERNATIONAL 2020; 2020:1920352. [PMID: 32337227 PMCID: PMC7166285 DOI: 10.1155/2020/1920352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Revised: 01/29/2020] [Accepted: 03/07/2020] [Indexed: 11/17/2022]
Abstract
Purpose To compare IOP and ocular hypotensive medication reduction of using one trabecular microbypass stent versus two in patients with open-angle glaucoma. Setting. Palo Alto Veterans Affairs (VA) Hospital and the Byers Eye Institute at Stanford University, Palo Alto, California, USA. Design Retrospective case series. Methods A chart review included patients who underwent trabecular microbypass implantation with cataract surgery in 2015-2017, with at least one-year follow-up. Subjects were divided into two groups by location (always one stent at Stanford versus two stents at the VA). Primary outcome measures included IOP and medication reduction at baseline and 12-month follow-up. Results 132 subjects (166 eyes) were included. The preoperative IOP was 16.3 ± 3.4 mmHg on 2.6 ± 1.1 medications in the one-stent group (N = 85) and 17.5 ± 3.1 mmHg on 2.7 ± 0.6 medications in the two-stent group (N = 81). There was no significant difference between the two groups (p = 0.06). At the 12-month visit, there was a 13.37% ± 2.93 reduction in IOP in the 1-stent group (p ≤ 0.001) and 13.49% ± 2.69 in the 2-stent group (p ≤ 0.001); both were not significantly different from each other (p = 0.074). At 12 months, there was also a 14.5% reduction in medication use for the 1-stent group and 15.3% reduction in the 2-stent group, both statistically significant from baseline, (p = 0.022 and p = 0.037, respectively). Conclusions Implantation with either one or two stents during cataract surgery in patients with glaucoma demonstrated similar IOP and med reduction in both groups between the two sites.
Collapse
|
39
|
Salby AM, Skalicky SE. Combined iStent ® Inject Trabecular Micro-Bypass and Phacoemulsification in Australian Patients with Open-Angle Glaucoma. Clin Ophthalmol 2020; 14:985-993. [PMID: 32280193 PMCID: PMC7127814 DOI: 10.2147/opth.s241628] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 03/09/2020] [Indexed: 11/30/2022] Open
Abstract
Purpose This retrospective audit aimed to evaluate the impact of combined iStent®Inject (iSI) and phacoemulsification on medication number in Australians with open-angle glaucoma. Secondary outcomes included intraocular pressure (IOP), best-corrected visual acuity, refraction and visual fields. Patients and Methods Patients with glaucoma that received combined iSI and phacoemulsification by the same surgeon between 1 February 2016 and 1 February 2018 were audited for postoperative medication number, pressures after 1 day, 1 week, 4 weeks and 6, 12, 18 and 24 months, visual acuity, refraction and visual fields. These parameters were compared to baseline levels and with those from a separate cohort of patients without glaucoma that received standalone phacoemulsification. Results Forty-one patients (63 eyes) received the combined procedure. Thirty-four patients (59 eyes) received standalone phacoemulsification. Four weeks after receiving combined iSI and phacoemulsification the mean medication number was significantly reduced by 1.3 (p < 0.001) for those on medication at baseline and by 0.5 (p = 0.002) overall. Mean IOP was significantly reduced from baseline after 6 months (–16%; p = 0.012; n = 35) and 12 months (–29%; p = 0.004; n = 16). Patients receiving standalone phacoemulsification had short-term reductions in IOP at 4 weeks (–8%; p < 0.001; n = 57) and 6 months (–16%; p < 0.001; n = 32). These patients without glaucoma had lower pressures overall compared to those with glaucoma that received the combined procedure (p = 0.019). There were no differences in final visual acuity or refractive outcomes between groups. Conclusion This audit suggests that iSI and phacoemulsification are at least as effective in controlling IOP as medical therapy. It may have an important role in reducing the medication burden in Australians with cataract and glaucoma. This study is one of the first to confirm refractive stability in concomitant iSI and phacoemulsification.
Collapse
Affiliation(s)
- Alon M Salby
- Department of Ophthalmology, Royal Melbourne Hospital, Melbourne, VIC, Australia
| | - Simon E Skalicky
- Department of Ophthalmology, Royal Melbourne Hospital, Melbourne, VIC, Australia.,Glaucoma Unit, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| |
Collapse
|
40
|
Chen DZ, Sng CCA, Sangtam T, Thomas A, Shen L, Huang PK, Cheng J. Phacoemulsification vs phacoemulsification with micro‐bypass stent implantation in primary angle closure and primary angle closure glaucoma: A randomized single‐masked clinical study. Clin Exp Ophthalmol 2020; 48:450-461. [DOI: 10.1111/ceo.13721] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Revised: 12/15/2019] [Accepted: 12/30/2019] [Indexed: 12/11/2022]
Affiliation(s)
- David Z. Chen
- Department of OphthalmologyNational University Hospital Singapore Singapore
| | - Chelvin C. A. Sng
- Department of OphthalmologyNational University Hospital Singapore Singapore
- Glaucoma ServiceMoorfields Eye Hospital London UK
- Singapore Eye Research Institute Singapore Singapore
| | - Tiakumzuk Sangtam
- Department of Ophthalmology and Visual ScienceKhoo Teck Puat Hospital Singapore Singapore
| | - Anoop Thomas
- Department of Ophthalmology and Visual ScienceKhoo Teck Puat Hospital Singapore Singapore
| | - Liang Shen
- Biostatistics Unit, Yong Loo Lin School of MedicineNational University of Singapore Singapore Singapore
| | - Philemon K. Huang
- Department of Ophthalmology and Visual ScienceKhoo Teck Puat Hospital Singapore Singapore
| | - Jason Cheng
- Department of Ophthalmology and Visual ScienceKhoo Teck Puat Hospital Singapore Singapore
- Department of OphthalmologyUniversity of New South Wales, Liverpool Hospital Sydney Australia
| |
Collapse
|
41
|
Pantalon AD, Barata ADDO, Georgopoulos M, Ratnarajan G. Outcomes of phacoemulsification combined with two iStent inject trabecular microbypass stents with or without endocyclophotocoagulation. Br J Ophthalmol 2020; 104:1378-1383. [PMID: 31980421 DOI: 10.1136/bjophthalmol-2019-315434] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 01/09/2020] [Accepted: 01/13/2020] [Indexed: 11/04/2022]
Abstract
AIM Comparing outcomes after combined phacoemulsification, two iStents insertion and endocyclophotocoagulation (ECP) versus phacoemulsification-iStents alone. METHODS This is a longitudinal retrospective 12 months study in eyes with ocular hypertension or early-to-moderate open angle glaucoma. Level of disease, intraocular pressure (IOP) and tolerance of glaucoma medication were considered before planning surgery. Best-corrected visual acuity (BCVA-logMAR), IOP (mm Hg), number of medications were assessed at baseline, week 1, week 5, month 3, 6, 12 postop. MAIN OUTCOME percentage (%) in IOP reduction at 12 months vs medicated baseline. SECONDARY OUTCOMES absolute values of IOP/medication reduction, BCVA and postop complications. RESULTS The ICE2 (two iStents-cataract extraction-ECP) group included 63 eyes and Phaco-iStent group included 46 eyes. Baseline IOP was higher in the ICE2 than phaco-iStent group (19.97±4.31 mm Hg vs 17.63±3.86 mm Hg, p=0.004) and mean deviation was lower (-7.20±2.58 dB vs -4.94±4.51 dB, p=0.037). Number of medications were comparable at baseline: 2.22±1.06 (ICE2) vs 2.07±1.02 (phaco-iStent), p=0.442. At month 12 postop, IOP in the ICE2 group decreased 35% from baseline vs 21% in the phaco-iStent group (p=0.03); absolute IOP reduction was significantly lower than baseline in each group (p<0.001), yet final IOP was lower in the ICE2 group than phaco-iStent group (13.05±2.18 mm Hg vs 14.09±1.86 mm Hg, p=0.01). Similar results were found for glaucoma medication (1.24±1.05 in ICE2 group vs 1.39±1.03 in phaco-iStent group, p=0.01). Final BCVA was 0.11±0.18 (phaco-iStent group) vs 0.08±0.08 (ICE2 group), p=0.309. Safety outcomes were comparable between groups. CONCLUSION ICE2 procedure offers better results in IOP/medication reduction at 12 months than phacoemulsification-iStents alone.
Collapse
Affiliation(s)
- Anca Delia Pantalon
- Eye Unit and Eye Bank, Queen Victoria Hospital NHS Foundation Trust, East Grinstead, UK.,Ophthalmology, "St. Spiridon" University Hospital, Iasi, Romania
| | - Andre Diogo De Oliveira Barata
- Eye Unit and Eye Bank, Queen Victoria Hospital NHS Foundation Trust, East Grinstead, UK.,Ophthalmology, Santa Maria Central Hospital, Lisbon, Portugal
| | - Minas Georgopoulos
- Eye Unit and Eye Bank, Queen Victoria Hospital NHS Foundation Trust, East Grinstead, UK.,Ophthalmology, East Surrey Hospital, Redhill, UK
| | - Gokulan Ratnarajan
- Eye Unit and Eye Bank, Queen Victoria Hospital NHS Foundation Trust, East Grinstead, UK
| |
Collapse
|
42
|
Rosdahl JA, Gupta D. Prospective Studies of Minimally Invasive Glaucoma Surgeries: Systematic Review and Quality Assessment. Clin Ophthalmol 2020; 14:231-243. [PMID: 32158182 PMCID: PMC6986542 DOI: 10.2147/opth.s239772] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Accepted: 12/24/2019] [Indexed: 12/05/2022] Open
Abstract
Glaucoma is a common blinding disease; while there is no cure, effective treatments include medications, laser, and incisional surgery. There is significant interest from patients and doctors to develop safer surgical options throughout the spectrum of disease, to minimize treatment burden in mild glaucoma patients and to minimize risk of complications in patients needing more aggressive treatment. Surgical procedures called Minimally or Micro-Invasive Glaucoma Surgery (MIGS) are growing in popularity. Eighty-seven prospective studies on MIGS were identified and assessed for quality. Most (74%) did not have a control group. Twelve of the highest quality were reviewed. MIGS procedures appeared to have fewer complications, and lowered intraocular pressure, and reduced medication use. Studies were limited by small sample size, narrow spectrum of glaucomatous disease, and/or conflicts of interest. There is a need for high quality, independently funded and performed, comparative studies on the MIGS to help make treatment decisions.
Collapse
Affiliation(s)
- Jullia A Rosdahl
- Department of Ophthalmology, Duke University, Durham, NC27710, USA
| | - Divakar Gupta
- Department of Ophthalmology, Duke University, Durham, NC27710, USA
| |
Collapse
|
43
|
Lindstrom R, Sarkisian SR, Lewis R, Hovanesian J, Voskanyan L. Four-Year Outcomes of Two Second-Generation Trabecular Micro-Bypass Stents in Patients with Open-Angle Glaucoma on One Medication. Clin Ophthalmol 2020; 14:71-80. [PMID: 32021070 PMCID: PMC6968820 DOI: 10.2147/opth.s235293] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Accepted: 12/17/2019] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION This study evaluated long-term reductions in intraocular pressure (IOP) and medication following implantation of 2 second-generation trabecular micro-bypass stents (iStent inject®) in eyes with open-angle glaucoma (OAG) not controlled on 1 preoperative medication. MATERIAL AND METHODS In this prospective interventional multi-surgeon study, standalone implantation of 2 iStent inject stents was performed in 57 eyes of 57 subjects with OAG, preoperative IOP of 18-30 mmHg on 1 medication, and preoperative post-washout IOP of 22-38 mmHg. The main outcome measures included the proportions of eyes achieving medication-free IOP ≤18 mmHg, IOP ≤15 mmHg, or ≥20% IOP reduction versus preoperative unmedicated IOP. Assessments included IOP, medications, visual acuity, visual field, pachymetry, complications, and interventions. Subjects were followed for 48 months with follow-up continuing in all eyes. RESULTS At Month 48 (n=57), 95% of eyes achieved an IOP reduction of ≥20% without medication versus preoperative washout IOP; and although they had eliminated medication, 81% of eyes still had an IOP reduction of ≥20% versus preoperative IOP on 1 medication. Mean 48-month unmedicated IOP decreased by 46% to 13.2±1.6 mmHg vs 24.4±1.3 mmHg preoperatively (p<0.0001), with 95% of medication-free eyes having IOP ≤18mmHg and 82% having IOP ≤15mmHg. Over the course of follow-up, 3 eyes had medication added and 1 eye underwent a secondary glaucoma surgery, and safety parameters were favorable. DISCUSSION Standalone iStent inject implantation in OAG patients on 1 preoperative medication resulted in average IOP reduction to ≤15 mmHg with the elimination of medication and favorable safety through 48 months. TRIAL REGISTRATION ClinicalTrials.gov identifier, NCT02868190.
Collapse
Affiliation(s)
| | | | | | | | - Lilit Voskanyan
- S.V. Malayan Ophthalmology Centre, Glaucoma Department, Yerevan, Armenia
| |
Collapse
|
44
|
Neuhann R, Neuhann T. Second-generation trabecular micro-bypass stent implantation: Retrospective analysis after 12- and 24-month follow-up. EYE AND VISION (LONDON, ENGLAND) 2020; 7:1. [PMID: 31938714 PMCID: PMC6953161 DOI: 10.1186/s40662-019-0169-7] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 12/19/2019] [Indexed: 01/15/2023]
Abstract
BACKGROUND The study aimed to investigate the 24-month safety and efficacy of implantation of two second-generation iStent inject trabecular micro-bypass stents with concomitant cataract surgery. METHODS This consecutive case series included 164 eyes of 109 patients implanted with the iStent inject® device with concomitant cataract surgery. The series was comprised of eyes with primary open-angle glaucoma (n = 84), pseudoexfoliation glaucoma (n = 42), normal-tension glaucoma (n = 18), and ocular hypertension (n = 20). All 164 eyes reached 9-14 months of follow-up ("12-month consistent cohort"), with a subset of 88 eyes reaching 21-26 months of follow-up ("24-month consistent cohort"). Performance outcome measures included intraocular pressure (IOP) and number of glaucoma medications. Safety outcomes included intra- or postoperative complications, the need for secondary procedures and corrected distance visual acuity. Comparisons of change in continuous (e.g., IOP) and categorical (e.g., proportions of eyes on zero medications) measures between baseline and postoperative times were made with the paired t-test and McNemar's chi-squared test, respectively. RESULTS At 12 months postoperatively, IOP was reduced by 25.5% (from 20.0 ± 5.5 mmHg to 14.9 ± 2.0 mmHg; p < 0.001); at 24 months postoperatively, IOP was reduced by 26.6% (from 20.3 ± 6.1 mmHg to 14.9 ± 1.9 mmHg; p < 0.001). At 12 months postoperatively, mean number of glaucoma medications was reduced by 85.0% (from 2.0 ± 1.0 to 0.3 ± 0.8 medications; p < 0.001); at 24 months postoperatively, mean number of medications was reduced by 81.0% (from 2.1 ± 1.1 to 0.4 ± 0.8 medications; p < 0.001). After 12 months, 96.3% of eyes had an IOP ≤ 18 mmHg and 58.5% of eyes had an IOP ≤ 15 mmHg, with 81.1% of eyes free of any medication, compared to 1.8% of eyes medication-free in the 12-month cohort at baseline. After 24 months, 98.9% of eyes had an IOP ≤ 18 mmHg and 53.4% of eyes had an IOP ≤ 15 mmHg, with 72.7% free of medication compared to 1.1% of eyes medication-free in the 24-month cohort at baseline. Overall, a high safety profile was observed with no significant postoperative complications. CONCLUSIONS The insertion of iStent inject (comprised of two second-generation trabecular micro-bypass stents) with cataract surgery effectively provides a sustained reduction in IOP with a markedly improved medication burden up to 24 months postoperatively.
Collapse
Affiliation(s)
- Raphael Neuhann
- Ophthalmologikum Dr.Neuhann, Augentagesklinik Marienplatz, Marienplatz 18-19, 80331 Munich, Germany
| | - Tobias Neuhann
- Ophthalmologikum Dr.Neuhann, Augentagesklinik Marienplatz, Marienplatz 18-19, 80331 Munich, Germany
| |
Collapse
|
45
|
Lyssek-Boroń A, Krysik K, Jankowska-Szmul J, Grabarek BO, Osuch M, Kijonka M, Dobrowolski D. Comparison of Methods of Endotamponade Used During 23-Gauge Pars Plana Vitrectomy and the Risk of Raised Intraocular Pressure During 24-Month Follow-Up: A Retrospective Study of 196 Patients. Med Sci Monit 2019; 25:9327-9334. [PMID: 31811816 PMCID: PMC6916133 DOI: 10.12659/msm.918114] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Pars plana vitrectomy (PPV) is used to treat retinal conditions, including retinal detachment, and involves removal of the vitreous gel from the eye. Complications following PPV include raised intraocular pressure (IOP). This retrospective study aimed to compare methods of endotamponade used during 23-gauge PPV and the risk of raised IOP during 24-month follow-up at a single center. MATERIAL AND METHODS The study included 196 patients (age, 15-86 years; mean, 63.5 years) (196 eyeballs). There were 93 patients (47.45%) with a preoperative history of type 2 diabetes mellitus and 14 patients (7.14%) with a history of myopia. IOP was measured with Goldmann applanation tonometry at one-, three-, six-, 12-, and 24-month follow-up. The outcome was compared following endotamponade with silicone oil, sulfur hexafluoride (SF6), and balanced salt solution (BSS). RESULTS Mean IOP at one-month follow-up was 17.2 mmHg (±3.61 mmHg; range, 9-45 mmHg), and at 24-month follow-up was 17.3 mmHg (±3.23 mmHg; range, 7-30 mmHg). IOP following PPV was significantly associated with the indication for PPV (P=0.023), and the type of endotamponade used (P=0.049). In patients with silicone oil endotamponade, the risk of IOP at 24 months was increased by 2.3 times compared with SF6 or BSS endotamponade. Patients with SF6 endotamponade had a risk of IOP that was 3.3 times lower than for silicone oil tamponade or BSS tamponade. CONCLUSIONS Silicone oil endotamponade in PPV was associated with an increased risk of IOP at 24-month follow-up.
Collapse
Affiliation(s)
- Anita Lyssek-Boroń
- Department of Ophthalmology with Pediatric Unit, St. Barbara Hospital Trauma Center, Sosnowiec, Poland
| | - Katarzyna Krysik
- Department of Ophthalmology with Pediatric Unit, St. Barbara Hospital Trauma Center, Sosnowiec, Poland
| | - Judyta Jankowska-Szmul
- Department of Ophthalmology with Pediatric Unit, St. Barbara Hospital Trauma Center, Sosnowiec, Poland.,Clinical Department of Ophthalmology, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Poland
| | - Beniamin Oskar Grabarek
- Katowice School of Technology, The University of Science and Art in Katowice, Katowice, Poland.,Center of Oncology, M. Sklodowska-Curie Memorial Institute, Cracow Branch, Cracow, Poland.,Department of Molecular Biology, School of Pharmacy with the Division of Laboratory Medicine in Sosnowiec, Medical University of Silesia in Katowice, Katowice, Poland
| | - Mateusz Osuch
- Department of Ophthalmology with Pediatric Unit, St. Barbara Hospital Trauma Center, Sosnowiec, Poland
| | - Magdalena Kijonka
- Department of Ophthalmology with Pediatric Unit, St. Barbara Hospital Trauma Center, Sosnowiec, Poland
| | - Dariusz Dobrowolski
- Department of Ophthalmology with Pediatric Unit, St. Barbara Hospital Trauma Center, Sosnowiec, Poland.,Clinical Department of Ophthalmology, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Poland
| |
Collapse
|
46
|
Salimi A, Lapointe J, Harasymowycz P. One-Year Outcomes of Second-Generation Trabecular Micro-Bypass Stents (iStent Inject) Implantation with Cataract Surgery in Different Glaucoma Subtypes and Severities. Ophthalmol Ther 2019; 8:563-575. [PMID: 31538316 PMCID: PMC6858422 DOI: 10.1007/s40123-019-00214-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Indexed: 02/08/2023] Open
Abstract
PURPOSE To assess the 1-year efficacy and safety of the implantation of two second-generation trabecular micro-bypass stents (iStent Inject®) with concomitant cataract surgery in various subtypes and severities of glaucoma. METHODS This single-surgeon, consecutive case series from a Canadian academic ophthalmology center included subjects with cataract, glaucoma, and the need to reduce intraocular pressure (IOP) and/or medications. The 12-month outcomes included mean IOP and medication burden as well as the proportions of eyes with IOP ≤ 18, ≤ 15, and ≤ 12 mmHg compared to baseline. Other measures included corrected distance visual acuity (CDVA), cup-to-disc ratio (CDR), visual field mean deviation (VF MD), retinal nerve fiber layer (RNFL) thickness, ganglion cell inner plexiform layer (GCIPL) thickness, and adverse events. RESULTS In 118 eyes, mean IOP reduced from 17.00 ± 3.82 mmHg preoperatively to 13.97 ± 2.65 mmHg at the 12-month follow-up mark (17.8% reduction, p < 0.001), and mean medication burden decreased from 2.31 ± 1.33 preoperatively to 1.03 ± 1.10 medications (56% reduction, p < 0.001). After 12 months, 93% of eyes achieved IOP ≤ 18 mmHg (versus 69% preoperatively), 70% of eyes achieved IOP ≤ 15 mmHg (versus 42% preoperatively), and 29% of eyes achieved IOP ≤ 12 mmHg (versus 7% preoperatively). For all eyes, topical medications were either maintained or decreased from baseline, with ≥ 1 medication eliminated from the preoperative regimen for 83% of eyes and ≥ 2 medications eliminated for 36% of eyes. Visual acuity improved significantly, consistent with expectations for cataract surgery, while CDR, VF MD, and RNFL and GCIPL thicknesses remained stable. Safety was favorable, with no intraoperative complications and few transient adverse events postoperatively. CONCLUSION iStent Inject implantation with cataract surgery safely reduced IOP and medication burden in a real-world clinical population with mild to severe glaucoma, and stabilized visual field, as well as RNFL and GCIPL thicknesses on OCT. FUNDING The Rapid Service Fees were funded by Glaukos Corporation.
Collapse
Affiliation(s)
- Ali Salimi
- Faculty of Medicine, McGill University, Montreal, QC, Canada
- Montreal Glaucoma Institute, Montreal, QC, Canada
| | - Julie Lapointe
- Montreal Glaucoma Institute, Montreal, QC, Canada
- Department of Ophthalmology, University of Sherbrooke, Sherbrooke, QC, Canada
| | - Paul Harasymowycz
- Montreal Glaucoma Institute, Montreal, QC, Canada.
- Department of Ophthalmology, University of Montreal, Montreal, QC, Canada.
| |
Collapse
|
47
|
Manning D. Real-world Case Series of iStent or iStent inject Trabecular Micro-Bypass Stents Combined with Cataract Surgery. Ophthalmol Ther 2019; 8:549-561. [PMID: 31422555 PMCID: PMC6858412 DOI: 10.1007/s40123-019-00208-x] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Indexed: 10/28/2022] Open
Abstract
INTRODUCTION This real-world retrospective case series assessed 12-month effectiveness and safety following implantation of iStent® or iStent inject® trabecular micro-bypass with cataract surgery. METHODS Consecutive patients were implanted with either iStent (comprising 1 stent) or iStent inject (comprising 2 stents), together with cataract surgery. Most patients had primary open-angle glaucoma. Effectiveness outcomes through 12 months included intraocular pressure (IOP) and glaucoma medications. Proportional analyses were completed for eyes achieving IOP ≤ 18 mmHg, IOP ≤ 15 mmHg, or IOP reduction ≥ 20% from preoperative; and eyes on 0 medications or ≥ 2 medications. Safety outcomes included adverse events, secondary surgeries, visual acuity, and visual fields. RESULTS This analysis included 137 eyes (67 iStent, 70 iStent inject) with cataract and mild to moderate glaucoma or ocular hypertension. Over 73% of eyes in both groups had early disease, and ~ 22% had prior glaucoma surgery. At 12 months postoperatively, mean IOP decreased from 18.4 ± 4.2 mmHg to 14.2 ± 2.5 mmHg in iStent eyes (p < 0.0001), and from 20.4 ± 5.6 mmHg to 14.4 ± 2.1 mmHg in iStent inject eyes (p < 0.0001). The IOP reduction was significantly greater for iStent inject eyes than iStent eyes (6.0 mmHg versus 4.2 mmHg reduction, p = 0.034). Both groups had high proportions of patients achieving the 12-month IOP endpoints, although consistently greater proportions reached these endpoints after iStent inject than iStent: 95.7% versus 92.5% had IOP ≤ 18 mmHg, respectively; 74.3% versus 71.6% had IOP ≤ 15 mmHg, respectively; and 68.6% versus 62.7% had IOP reduction ≥ 20% from baseline, respectively. Mean medication burden at 12 months decreased from 1.8 ± 0.7 to 0.3 ± 0.5 medications in iStent eyes (84.0% reduction, p < 0.0001), and from 1.3 ± 0.9 to 0.1 ± 0.3 medications in iStent inject eyes (94.7% reduction, p < 0.0001). Significantly more iStent inject eyes were medication-free at 12 months than iStent eyes (92.9% versus 76.1% medication-free, respectively; p = 0.0068). Favorable safety included few adverse events, no secondary glaucoma surgeries, and stable visual acuity and visual fields in both groups. CONCLUSION Significant and safe IOP and medication reductions were achieved through 12 months after iStent or iStent inject implantation with cataract surgery. iStent inject eyes had greater absolute IOP reduction and more eyes medication-free versus iStent eyes. FUNDING Glaukos Corporation.
Collapse
Affiliation(s)
- David Manning
- Hunter Cataract and Eye Centre, Charlestown, NSW, Australia.
| |
Collapse
|
48
|
Guedes RAP, Gravina DM, Lake JC, Guedes VMP, Chaoubah A. One-Year Comparative Evaluation of iStent or iStent inject Implantation Combined with Cataract Surgery in a Single Center. Adv Ther 2019; 36:2797-2810. [PMID: 31440981 PMCID: PMC6822971 DOI: 10.1007/s12325-019-01067-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Indexed: 11/20/2022]
Abstract
INTRODUCTION This retrospective consecutive case series assessed 12-month effectiveness and safety of iStent® or iStent inject® trabecular micro-bypass implants with cataract surgery in patients with open-angle glaucoma (OAG) in a real-world clinical setting. METHODS Effectiveness outcomes consisted of intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving IOP < 18, < 15, or < 12 mmHg; and proportional analysis of medication usage. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA). RESULTS This evaluation included 58 eyes with OAG (35 iStent, 23 iStent inject), with 96.6% of eyes having mild or moderate glaucoma. Diagnoses included primary open-angle glaucoma (the majority; 72.4%), pseudoexfoliative glaucoma, and pigmentary glaucoma. Baseline mean IOP and medications were statistically comparable between groups: 16.1 ± 3.6 mmHg on a mean of 1.8 ± 0.8 medications in the iStent group, and 16.2 ± 3.1 mmHg on a mean of 1.7 ± 0.8 medications in the iStent inject group. Twelve months after stent-cataract surgery, mean IOP was significantly lower in the iStent inject group than in the iStent group (13.1 mmHg vs. 15.4 mmHg, respectively; p < 0.001), and the percent reduction in IOP from baseline was significantly greater in iStent inject eyes than in iStent eyes (19.1% vs. 4.3% reduction, respectively; p < 0.001). At 12 months postoperative, significantly greater proportions of iStent inject eyes than iStent eyes achieved IOP < 18 mmHg (100% vs. 80.0% of eyes, respectively; p = 0.035), IOP < 15 mmHg (73.9% vs. 34.3% of eyes, respectively; p = 0.003), and IOP < 12 mmHg (26.1% vs. 0% of eyes, respectively; p = 0.002). Meanwhile, both groups achieved significant medication reductions at 12 months vs. baseline (94.1% reduction in iStent inject eyes, p < 0.0001; and 72.2% reduction in iStent eyes, p < 0.0001), with the percent reduction being significantly greater in iStent inject eyes than in iStent eyes (p = 0.023). At 12 months, mean number of medications was significantly lower in iStent inject eyes than iStent eyes (0.1 vs. 0.5 medications, respectively; p = 0.021), and significantly more iStent inject eyes (95.7%) than iStent eyes (71.4%) were off medications entirely (p = 0.021). A similarly high safety profile was observed in both groups. CONCLUSION iStent or iStent inject implantation with cataract surgery resulted in substantial and safe reductions in IOP and medications through 12 months postoperative. Consistent with prior observations, greater efficacy was observed with iStent inject than with iStent. FUNDING The Rapid Service Fees were funded by Glaukos Corporation.
Collapse
Affiliation(s)
- Ricardo Augusto Paletta Guedes
- Paletta Guedes Eye Institute, Juiz de Fora, Minas Gerais, Brazil.
- Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.
| | | | | | | | - Alfredo Chaoubah
- Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil
| |
Collapse
|
49
|
Salimi A, Winter A, Li C, Harasymowycz P, Saheb H. Effect of Topical Corticosteroids on Early Postoperative Intraocular Pressure Following Combined Cataract and Trabecular Microbypass Surgery. J Ocul Pharmacol Ther 2019; 35:413-420. [DOI: 10.1089/jop.2019.0019] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Ali Salimi
- Faculty of Medicine, McGill University, Montreal, Quebec, Canada
| | - Aaron Winter
- Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Cody Li
- Department of Ophthalmology, McGill University, Montreal, Quebec, Canada
| | - Paul Harasymowycz
- Department of Ophthalmology, University of Montreal, Montreal, Quebec, Canada
- Montreal Glaucoma Institute, Montreal, Quebec, Canada
| | - Hady Saheb
- Department of Ophthalmology, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
50
|
Hengerer FH, Auffarth GU, Riffel C, Conrad-Hengerer I. Second-Generation Trabecular Micro-Bypass Stents as Standalone Treatment for Glaucoma: A 36-Month Prospective Study. Adv Ther 2019; 36:1606-1617. [PMID: 31119690 PMCID: PMC6824385 DOI: 10.1007/s12325-019-00984-9] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Indexed: 11/13/2022]
Abstract
Introduction To evaluate long-term outcomes following stand-alone implantation of two second-generation trabecular micro-bypass stents (iStent inject®, Glaukos Corp., San Clemente, CA, USA) in eyes with predominantly primary open-angle glaucoma (POAG) and considerable preoperative disease burden. Methods Eyes with POAG, pseudoexfoliative glaucoma (PXG), appositional narrow-angle glaucoma (NAG, with open-angle configuration in the area of implantation), or secondary glaucoma were included in this prospective, non-randomized, consecutive case series. All eyes underwent ab interno iStent inject implantation as a sole procedure. Assessments through 36 months included IOP, medications, corrected distance visual acuity (CDVA), secondary glaucoma surgeries, and complications and adverse events. Results Two iStent inject stents were implanted in 44 consecutive eyes (POAG = 38, PXG = 4, appositional NAG = 1, secondary neovascular glaucoma = 1) of 31 patients, and 33 eyes had 36-month follow-up data. Preoperative mean IOP was 25.3 ± 6.0 mmHg on a mean of 2.98 ± 0.88 medications, with 75% of eyes on 3–5 medications, no eyes medication-free, and 50% of eyes with history of prior glaucoma surgery. At 36 months postoperatively, mean IOP reduced by 42% to 14.6 ± 2.0 mmHg (p < 0.0001) and 87.9% of eyes achieved an IOP reduction of ≥ 20% versus preoperatively. In addition, 97% of eyes reached IOP ≤ 18 mmHg (vs. 9.1% preoperatively; p < 0.0001) and 70.0% of eyes reached IOP ≤ 15 mmHg (vs. 2.3% preoperatively; p < 0.0001). Mean medication burden decreased by 82% to 0.55 ± 0.79 (p < 0.0001), and 61% of eyes became medication-free. All eyes maintained or decreased their 36-month medication burden versus preoperatively. Safety was favorable, including minimal adverse events and stable CDVA through 36 months postoperatively. Conclusion This real-world cohort of glaucomatous eyes with substantial preoperative disease burden experienced significant, sustained, safe IOP and medication reductions through 36 months following stand-alone iStent inject implantation. Funding Article processing charges and writing assistance were provided by Glaukos Corp. (San Clemente, CA, USA).
Collapse
|