1
|
Koerber N, Ondrejka S. 6-Year Efficacy and Safety of iTrack Ab-Interno Canaloplasty as a Stand-Alone Procedure and Combined With Cataract Surgery in Primary Open Angle and Pseudoexfoliative Glaucoma. J Glaucoma 2024; 33:176-182. [PMID: 37725787 DOI: 10.1097/ijg.0000000000002311] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 09/04/2023] [Indexed: 09/21/2023]
Abstract
PRCIS Significant reductions in intraocular pressure (IOP) and the number of medications are sustained up to 6 years postoperatively for eyes that underwent ab-interno canaloplasty using the iTrack microcatheter, either as a stand-alone procedure or combined with cataract surgery. PURPOSE The purpose of this study was to evaluate the long-term effectiveness of iTrack (Nova Eye Medical Inc.) ab-interno canaloplasty for reducing IOP and the number of glaucoma medications in patients with primary open angle (POAG) and pseudoexfoliative glaucoma. METHODS A retrospective single-center consecutive case series. Patients were treated with either ab-interno canaloplasty performed as a stand-alone procedure or combined with cataract surgery and were followed for up to 6 years. iTrack was used to circumferentially catheterize and viscodilate the Schlemm canal over 360 degrees. Primary efficacy endpoints included IOP and number of glaucoma medications at 12, 24, 36, 48, 60, and 72 months after surgery. RESULTS Twenty-seven eyes of 22 patients, with a mean age of 76.9±6.3 years, were recruited. Mean IOP was reduced significantly from 19.9±5.2 mm Hg (n=27) at baseline (no washout) to 14.6±3.3 mm Hg at the 6-year follow-up (n=18; P <0.001). The number of medications was significantly reduced from 1.9±1 at baseline to 0.9±0.9 at 6 years (n=18; P =0.005). At all time points, there was no statistical difference between POAG (n=16) and pseudoexfoliative (n=11) eyes, nor between stand-alone procedures (n=4) and those combined with phacoemulsification (n=23). At 72 months, the mean reduction in IOP was 27% while 53% in the number of medications. No serious complications were recorded. CONCLUSIONS iTrack ab-interno canaloplasty performed as a stand-alone procedure or in combination with cataract surgery significantly reduced IOP and number of medications in patients with POAG up to 6 years after the procedure. To the authors' knowledge, this is the longest ab-interno canaloplasty follow-up available in the literature.
Collapse
|
2
|
Gillmann K, Hornbeak DM. Rates of visual field change and functional progression in glaucoma following trabecular microbypass implantation of iStent technologies: a meta-analysis. BMJ Open Ophthalmol 2024; 9:e001575. [PMID: 38360043 PMCID: PMC10875546 DOI: 10.1136/bmjophth-2023-001575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 01/30/2024] [Indexed: 02/17/2024] Open
Abstract
BACKGROUND/AIM While intraocular pressure (IOP) remains the only modifiable risk factor for glaucoma progression, the ultimate goal of glaucoma management is to preserve patients' functional vision and quality of life. To this end, minimally invasive glaucoma surgeries (MIGSs) aim to reduce IOP with minimal eye trauma. Commonly used MIGS devices include iStent technologies, which have well-documented IOP-reducing potential and favourable safety profiles. However, no study concluded on their effect on the rates of visual field (VF) changes. The aim of this meta-analysis is to determine the long-term effect of iStent technology implantation on glaucoma functional progression. METHODS Electronic medical literature databases were searched to identify studies reporting on iStent technologies. Reports with follow-up durations <12 months, retention rates <75% and missing VF data were excluded. Fifteen studies reporting on 1115 eyes were identified. The overall weighted mean VF mean deviation (MD) progression, IOP reduction and follow-up duration were calculated. RESULTS Weighted mean IOP at baseline was 19.0±3.1 mm Hg. At the end of a 37.9-month mean follow-up (range 12-96 months), a weighted mean 26.6% IOP reduction was achieved (range 15.2%-42.3%). Over the same duration, the weighted mean VF MD progression rate was -0.02±0.34 dBs/year, from a mean baseline of -5.76±5.68 dBs. CONCLUSION In this review, which examines functional stability of 1115 eyes, iStent technologies achieved a mean rate of progression of -0.024 dBs/year with serial standard automated perimetry, which is similar to that reported in non-glaucomatous eyes and slower than that reported in medically treated glaucoma.
Collapse
Affiliation(s)
- Kevin Gillmann
- Genève Ophtalmologie, Geneva, Switzerland
- Stanford University, Palo Alto, California, USA
| | | |
Collapse
|
3
|
Chan PPM, Larson MD, Dickerson JE, Mercieca K, Koh VTC, Lim R, Leung EHY, Samuelson TW, Larsen CL, Harvey A, Töteberg-Harms M, Meier-Gibbons F, Shu-Wen Chan N, Sy JB, Mansouri K, Zhang X, Lam DSC. Minimally Invasive Glaucoma Surgery: Latest Developments and Future Challenges. Asia Pac J Ophthalmol (Phila) 2023; 12:537-564. [PMID: 38079242 DOI: 10.1097/apo.0000000000000646] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 10/12/2023] [Indexed: 12/21/2023] Open
Abstract
The development of minimally invasive glaucoma surgeries (MIGSs) was intended to provide safe and modestly efficacious modalities for early intervention of mild-to-moderate glaucoma, with minimal trauma and rapid recovery. They were mainly ab interno procedures that reduce intraocular pressure by facilitating the aqueous outflow by bypassing the trabecular meshwork resistance, reinforcing the uveoscleral flow via the supraciliary space, and reducing aqueous production by the ciliary body. While the cumulating evidence helps shape the role of the available MIGS, the exponential new development and advancement in this field has expanded the territory of MIGS. Apart from developing subconjunctival MIGS filtration devices (Xen gel stent and PRESERFLO MicroShunt), there is a tendency to revisit the "traditional" MIGS for alternative use and to modify the procedures with consideration of the fundamental aqueous outflow physiology. Combined MIGS has also been suggested, based on the theory that their different mechanisms may provide additive or synergistic effects. The advancement of laser procedures is also promising and could supplement unmet needs along the glaucoma treatment algorithm. This review examines the broad array of MIGS, updates the recent findings, discusses their potential alternative applications, and explores future challenges.
Collapse
Affiliation(s)
- Poemen P M Chan
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
- Department of Ophthalmology and Visual Sciences, Lam Kin Chung. Jet King-Shing Ho Glaucoma Treatment and Research Centre, The Chinese University of Hong Kong, Hong Kong, China
| | | | - Jaime E Dickerson
- Sight Sciences, Menlo Park, CA, USA
- University of North Texas Health Science Center, North Texas Eye Research Institute, Fort Worth, TX, USA
| | | | - Victor Teck Chang Koh
- Department of Ophthalmology, National University Health System, Singapore
- Centre for Innovation and Precision Eye Health, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Ridia Lim
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Enne Hiu Ying Leung
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
| | - Thomas W Samuelson
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | - Christine L Larsen
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | | | - Marc Töteberg-Harms
- Department of Ophthalmology, Augusta University, Medical College of Georgia, Augusta, GA, USA
| | | | | | - Jessica Belle Sy
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Baguio General Hospital and Medical Center, Baguil City, Benguet, Philippines
| | - Kaweh Mansouri
- Glaucoma Center, Swiss Visio, Clinique de Montchoisi, Lausanne, Switzerland
| | - Xiulan Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Dennis S C Lam
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
- The International Eye Research Institute of The Chinese University of Hong Kong (Shenzhen), Shenzhen, China
| |
Collapse
|
4
|
Lima FE, Geraissate JC, Ávila MP. A multicenter prospective comparative study evaluating cataract surgery and endoscopic cyclophotocoagulation either with or without iStent inject implantation in Brazilian patients with glaucoma. Int Ophthalmol 2022; 43:1665-1676. [PMID: 36273360 PMCID: PMC10149466 DOI: 10.1007/s10792-022-02563-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 10/10/2022] [Indexed: 11/24/2022]
Abstract
Abstract
Purpose
Compare 12-month (12 M) safety and efficacy of endoscopic cyclophotocoagulation (ECP) + cataract surgery (Group 1) versus ECP + cataract surgery + iStent inject trabecular micro-bypass implantation (Group 2) in Brazilian patients with open-angle glaucoma (OAG).
Methods
This prospective, multicenter, comparative case series included patients with OAG and cataract who were randomized to receive treatment in Group 1 or Group 2. Outcomes included mean and percent reduction versus preoperative in intraocular pressure (IOP) and number of glaucoma medications; visual acuity; occurrence of adverse events; and rate of secondary surgeries.
Results
Preoperatively, Groups 1 and 2 had similar mean IOP (mean ± standard deviation 22.1 ± 3.6 and 22.0 ± 2.5 mmHg, respectively) and mean number of medications (3.3 ± 0.6 and 3.4 ± 0.6 medications, respectively). At all follow-up timepoints through 12 M, both groups achieved significant IOP and medication reductions versus preoperative (IOP p < 0.001 and number of medications p < 0.001 for both groups). At 12 M, IOP reductions were 24.2% (Group 1) and 43.6% (Group 2) (p < 0.001); mean medication reductions were 50.2% and 71.5%, respectively. Mean postoperative IOP and number of medications were higher in Group 1 than Group 2 (IOP p < 0.01 all visits, medication p < 0.01 at 6 M and 12 M). Adverse events were generally mild and infrequent in both groups.
Conclusion
Both treatment groups (ECP + phacoemulsification, with/without iStent inject implantation) achieved significant and safe reductions in IOP and medications versus preoperative in Brazilian OAG patients. Percent reductions were significantly greater, and mean IOP and medications were significantly lower, in the group receiving iStent inject.
Clinical trial registration (CTR)
CAAE project identification #20053019.5.0000.5078. Protocol #3.587.147. Clinical Trial Database of the Federal University of Goiás, Brazil. Registration Date: September 19, 2019.
Collapse
Affiliation(s)
- Francisco E. Lima
- Federal University of Goiás, Goiânia, Brazil
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
| | - João C. Geraissate
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
- Centro Brasileiro da Visão, Brasília, Brazil
| | - Marcos P. Ávila
- Federal University of Goiás, Goiânia, Brazil
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
- Centro Brasileiro da Visão, Brasília, Brazil
| |
Collapse
|
5
|
Clement C, Howes F, Ioannidis A, Shiu M, Manning D, Lusthaus JA, Skalicky SE, Goodwin TW. Multicenter Effectiveness and Disease Stability Through 3 Years After iStentTrabecular Micro-Bypass with Phacoemulsification in Glaucoma and Ocular Hypertension. Clin Ophthalmol 2022; 16:2955-2968. [PMID: 36071724 PMCID: PMC9444145 DOI: 10.2147/opth.s373290] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To evaluate 3-year safety and efficacy of two second-generation trabecular micro-bypass stents. (iStent inject®) with phacoemulsification. Materials and Methods This multicenter retrospective study of iStent inject implantation with phacoemulsification included data from eight surgeons across Australia. Eyes with cataract and mild to advanced glaucoma [predominantly primary open-angle (POAG), primary angle closure (PAC), or normal-tension (NTG) glaucoma] or ocular hypertension (OHT) were included. Study assessments included intraocular pressure (IOP); number of ocular hypotensive medications; proportions of eyes with 0, 1, 2, or ≥3 IOP-lowering medications; IOP ≤15 mmHg or ≤18 mmHg; visual fields (VF); retinal nerve fiber layer thickness (RNFL); central corneal thickness (CCT); intraoperative complications; adverse events; and secondary surgeries. Results A total of 273 eyes underwent surgery and had 36-month follow-up. At 36 months versus preoperative, mean IOP decreased by 15.5% (16.4±4.6 mmHg to 13.9±3.5 mmHg; p<0.001), and 70.3% of eyes achieved IOP of ≤15 mmHg (versus 49.1% preoperatively; p<0.001). The mean medication burden decreased by 68.5% (from 1.51±1.17 to 0.48±0.89 medications; p<0.001); 71.4% of eyes were medication-free (versus 21.6% preoperatively; p<0.001), while 6.2% of eyes were on ≥3 medications (versus 22.3% preoperatively; p<0.001); 96.3% of eyes maintained or reduced medications vs preoperative. Significant IOP and medication reductions occurred across glaucoma subtypes (POAG, PAC, NTG, OHT): 13–22% for IOP (p<0.05 for all) and 42–94% for medication (p<0.05 for all). Favorable safety included few adverse events; stable VF, RNFL, and CCT; and filtering surgery in only 8 eyes (2.9%) over 3 years. Conclusion In this multicenter cohort from 8 surgeons across Australia, significant IOP and medication reductions were sustained through 3 years after iStent inject implantation with phacoemulsification. Results were favorable across different glaucoma subtypes (including POAG, PAC, NTG, OHT), severities, and surgeons, thereby underscoring the real-world relevance and efficacy of iStent inject implantation for glaucoma treatment.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia
- Fairfield Eye Surgery, Fairfield, NSW, Australia
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Correspondence: Colin Clement, Eye Associates, Level 4, 187 Macquarie Street, Sydney, NSW, 2000, Australia, Tel +612 9247 9972, Email
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed A Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Eyehaus, Sydney, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
6
|
Inatani M, Kohama I, Chu A. iStent Trabecular Micro-bypass Stent Implantation Combined with Phacoemulsification for Open-Angle Glaucoma: A 2-Year Post-marketing Surveillance Study in Japan. Adv Ther 2022; 39:4076-4093. [PMID: 35790641 PMCID: PMC9402767 DOI: 10.1007/s12325-022-02207-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/24/2022] [Indexed: 11/18/2022]
Abstract
Introduction We report 2-year outcomes after implantation of iStent trabecular micro-bypass stent with phacoemulsification, in Japanese patients with mild–moderate open-angle glaucoma (OAG). Methods This was a 24-month, prospective, longitudinal, observational, post-marketing study conducted between July 2017 and September 2020. Patients consisted of adults with OAG on antiglaucoma medications who had cataract surgery combined with one iStent implantation. Outcome measures included intraocular pressure (IOP), antiglaucoma medications, treatment success rates (defined as eyes having lower IOP with same or reduced number of medications from baseline, or same IOP with reduced number of medications from baseline, and not requiring secondary glaucoma surgeries postoperatively), and safety. Outcomes were analyzed in the overall cohort and in glaucoma subtypes: primary OAG, normal-tension glaucoma, and exfoliative glaucoma. Results Overall, 232 eyes were enrolled. At 24 months, mean ± standard deviation IOP decreased from 17.6 ± 4.0 mmHg preoperatively to 14.3 ± 3.0 mmHg (p < 0.05), and mean number of medications reduced from 2.2 ± 1.2 preoperatively to 0.7 ± 1.2 (p < 0.05). Similar trends were observed across glaucoma subtypes. In the overall cohort, 96.7%, 95.3%, and 93.7% of patients achieved treatment success at 6, 12, and 24 months, respectively. There were 67.6% medication-free eyes at 24 months compared to 3.2% medication-free eyes preoperatively (p < 0.0001). Safety profile was favorable over the 2-year period. Conclusions Following iStent implantation with phacoemulsification, clinically relevant and statistically significant reductions in IOP and number of medications were observed in Japanese eyes with OAG over 2 years, with favorable safety profile. These reductions were observed across all glaucoma subtypes. Supplementary Information The online version contains supplementary material available at 10.1007/s12325-022-02207-0.
Collapse
Affiliation(s)
- Masaru Inatani
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Eiheiji, Yoshida, Fukui, 910-1193, Japan.
| | | | - Alice Chu
- Glaukos Corporation, Singapore, Singapore
| |
Collapse
|
7
|
Gallardo MJ. 36-month effectiveness of ab-interno canaloplasty standalone versus combined with cataract surgery for the treatment of open-angle glaucoma. Ophthalmol Glaucoma 2022; 5:476-482. [PMID: 35183815 DOI: 10.1016/j.ogla.2022.02.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Revised: 02/10/2022] [Accepted: 02/11/2022] [Indexed: 10/19/2022]
Abstract
PURPOSE To report the 36-month effectiveness of ab-interno canaloplasty performed with the iTrack microcatheter (Nova Eye Medical, Fremont, USA) as a standalone procedure or combined with cataract surgery. DESIGN A single-center, retrospective case series PARTICIPANTS: Eyes diagnosed with primary open-angle glaucoma (POAG). METHODS Eyes with POAG were treated with either ab-interno canaloplasty as a standalone procedure (iTrack-alone) or in conjunction with phacoemulsification (iTrack+phaco). MAIN OUTCOME MEASURES The main outcome was mean reduction in intraocular pressure (IOP) and number of glaucoma medications at 12, 24, and 36 months postoperatively. Secondary endpoints consisted of visual acuity and the rate of complications. RESULTS 44 eyes of 44 patients with open-angle glaucoma were included: 23 eyes in the iTrack-alone group and 21 eyes in the iTrack+phaco group. When both groups were analyzed together, both IOP and the number of medications were significantly reduced at 12 months (p<0.0001) and remained stable at 24 and 36 months. IOP decreased from 20.5±5.1 mmHg preoperatively to 13.3±2.1, 13.1±2.4 and 13.3±2.1 mmHg at 12-24-36 months respectively; the number of medications was reduced from 2.8±0.9 preoperatively to 1.1±1.1, 1.0±1.1 and 1.3±1.3 at 12-24 and 36 months postoperatively. Comparable results were observed in the iTrack-alone and iTrack+phaco groups, from a baseline 20.9±6.1 and 20.0±3.9 to 13.2±2.1 and 13.5±2.2 at 36-month respectively. At 36 months, 95.5% of eyes had IOP ≤17 mmHg and 68.2% of eyes were on ≤1 medication. No serious intra-operative or postoperative complications were reported. CONCLUSION Ab-interno canaloplasty performed with the iTrack microcatheter was found to be effective in reducing IOP and medication dependence. Comparable results were observed when employed as a standalone procedure or when combined with cataract surgery.
Collapse
|
8
|
Paletta Guedes RA, Gravina DM, Paletta Guedes VM, Chaoubah A. Standalone Implantation of 2-3 Trabecular Micro-Bypass Stents (iStent inject ± iStent) as an Alternative to Trabeculectomy for Moderate-to-Severe Glaucoma. Ophthalmol Ther 2022; 11:271-292. [PMID: 34825352 PMCID: PMC8770764 DOI: 10.1007/s40123-021-00424-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 11/01/2021] [Indexed: 12/04/2022] Open
Abstract
INTRODUCTION This retrospective consecutive study compared standalone implantation of multiple (2-3) trabecular micro-bypass stents (iStent inject ± iStent) (Multi-Stent group) vs trabeculectomy + mitomycin C (Trab group) in moderate to severe open-angle glaucoma (OAG). METHODS Eligible patients underwent Multi-Stent or Trab surgery from 2018 to 2020 and had at least 3-month follow-up; visual field mean deviation (VF MD) - 6 dB or worse; inadequate prior response to maximum medications ± laser procedures; and had trabeculectomy as their next planned intervention. Primary effectiveness, safety-adjusted treatment success, was defined as ≥ 20% intraocular pressure (IOP) reduction on the same or fewer medications, without clinically significant safety events (severe complications, secondary surgeries, reinterventions). Secondary effectiveness included mean IOP and medications; qualified and complete attainment of target IOP (≤ 21/18/15/12 mmHg and > 6 mmHg); health-economic and quality-of-life (QoL) measures; and 2-vs-3-stent subgroup analysis. RESULTS The baseline groups (n = 70 Multi-Stent/40 Trab) were similar: mean IOP (21.1 mmHg/22.3 mmHg); medications (2.87/3.10 medications); disease stage (30%/35% severe); VF MD (- 10.1 dB/- 10.4 dB); and mean last follow-up (LFU, 13.1 months/15.7 months) (all differences non-significant). Primary effectiveness: treatment success at LFU was 62.9% vs 30.0% in Multi-Stent vs Trab eyes, respectively (p = 0.001). Secondary effectiveness: At LFU in Multi-Stent vs Trab groups, respectively: mean IOP decreased by 31% to 14.2 mmHg (p < 0.001) vs by 43% to 12.5 mmHg (p < 0.001); mean medications decreased by 51% to 1.31 medications (p < 0.001) vs by 84% to 0.43 medications (p < 0.001). Multi-Stent eyes, compared to Trab eyes, had fewer visits ± reinterventions within 3 months (3.6 vs 6.1, p < 0.001); longer time to first reintervention (12.2 months vs 4.5 months, p = 0.01); fewer total reinterventions (0.26 vs 0.75, p = 0.006); and earlier lifting of postoperative restrictions (12.6 vs 32.1 days, p < 0.001). In 2-vs-3-stent analysis, there was a trend toward more 3-stent eyes achieving target IOP than 2-stent eyes. Visual fields remained stable in both Multi-Stent and Trab eyes. CONCLUSION Implanting 2-3 trabecular micro-bypass stents was a viable alternative to trabeculectomy for moderate-to-severe OAG, with clinically appropriate IOP/medication reductions and higher safety-adjusted treatment success vs trabeculectomy.
Collapse
Affiliation(s)
- Ricardo Augusto Paletta Guedes
- Paletta Guedes Eye Institute, Juiz de Fora, Brazil.
- Federal University of Juiz de Fora, 79, Oscar Vidal Street, Juiz de Fora, MG, Brazil.
| | | | | | - Alfredo Chaoubah
- Federal University of Juiz de Fora, 79, Oscar Vidal Street, Juiz de Fora, MG, Brazil
| |
Collapse
|
9
|
Singh IP, Sarkisian S, Hornbeak D, Katz LJ, Samuelson T. Treatment Success Across Different Levels of Preoperative Disease Burden: Stratified Two-Year Outcomes from the Pivotal Trial of iStent inject ® Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract. Clin Ophthalmol 2021; 15:3231-3240. [PMID: 34376967 PMCID: PMC8349204 DOI: 10.2147/opth.s316270] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 06/23/2021] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To examine effectiveness outcomes stratified by preoperative disease burden in the pivotal trial of iStent inject ® with cataract surgery (INJ) vs cataract surgery alone (CS). MATERIALS AND METHODS Prospective, 3:1 randomized, single-masked, concurrently-controlled, multicenter trial enrolling 505 subjects with cataract and mild-to-moderate primary open-angle glaucoma who underwent iStent inject implantation with phacoemulsification or phacoemulsification alone, and were followed for 2 years including annual medication washouts. Post hoc stratification was completed for baseline mean diurnal intraocular pressure (BL DIOP; Low-DIOP <25mmHg, Mid-DIOP ≥25 to <30 mmHg, High-DIOP ≥30mmHg) and preoperative medication burden (Low-Med 1 medication, Mid-Med 2 medications, High-Med ≥3 medications). RESULTS The 24-month primary and secondary effectiveness endpoints were met, with significant treatment-over-control differences in percent of eyes achieving ≥20% unmedicated DIOP reduction and in unmedicated DIOP reduction, respectively. In subgroup analyses, the proportions of INJ eyes achieving the primary endpoint remained steady across all BL DIOP (75.4%, 77.1%, 74.4% in Low/Mid/High-DIOP strata, respectively) and preoperative medication levels (76.8%, 70.8%, 79.7% in Low/Mid/High-Med strata, respectively); meanwhile, the proportions of CS eyes diminished with higher BL DIOP (64.5%, 63.6%, 33.3%, respectively) and more medications (69.0%, 63.3%, 29.4%, respectively). Regarding secondary effectiveness, postoperative DIOP reduction increased with higher BL DIOP in INJ eyes (6.2mmHg, 7.8mmHg, 9.8mmHg, respectively) but plateaued in CS eyes (5.2mmHg, 5.8mmHg, 5.4mmHg, respectively). INJ eyes also had consistent DIOP reduction regardless of preoperative medication burden (6.8mmHg, 6.7mmHg, 7.8mmHg, respectively), while DIOP reduction diminished with more medications in CS eyes (6.1mmHg, 5.0mmHg, 3.3mmHg, respectively). Safety was favorable, comparable to phacoemulsification alone. CONCLUSION Significant IOP reductions occurred across all levels of BL DIOP and preoperative medication burden in iStent inject eyes. DIOP reductions increased with higher BL DIOP and remained stable across all levels of preoperative medication burden, suggesting the device's potential utility in more medically challenging cases.
Collapse
Affiliation(s)
| | | | | | - L Jay Katz
- Glaukos Corporation, San Clemente, CA, USA
- Wills Eye Hospital, Philadelphia, PA, USA
| | | |
Collapse
|
10
|
Paletta Guedes RA, Gravina DM, Paletta Guedes VM, Chaoubah A. Two-Year Comparative Outcomes of First- and Second-Generation Trabecular Micro-Bypass Stents with Cataract Surgery. Clin Ophthalmol 2021; 15:1861-1873. [PMID: 33981138 PMCID: PMC8108397 DOI: 10.2147/opth.s302684] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 03/18/2021] [Indexed: 12/13/2022] Open
Abstract
INTRODUCTION This retrospective comparative study assessed real-world effectiveness and safety of first-generation (iStent®) and second-generation (iStent inject®) trabecular micro-bypass stents with cataract surgery in patients with open-angle glaucoma (OAG). MATERIAL AND METHODS Through a 24-month postoperative follow-up, the effectiveness was quantified by intraocular pressure (IOP) reduction; mean glaucoma medication reduction; proportional analysis of eyes meeting IOP cutoffs (<18, <15, <12 mmHg) either with or without medications; and proportional analysis of medication burden. Safety measures included visual acuity, adverse events, and secondary surgery. RESULTS A total of 82 consecutive eyes (39 iStent, 43 iStent inject) with a 24-month follow-up were analyzed. Most eyes (74.4%) had primary open-angle glaucoma, with the remainder having pseudoexfoliative or pigmentary glaucoma; all eyes had mild-to-moderate disease. At 24 months postoperative, the mean IOP was lower, and the percent reduction from baseline was greater, in iStent inject eyes (26.0% reduction, 17.7mmHg to 13.1mmHg) than in iStent eyes (9.8% reduction, 16.4mmHg to 14.8mmHg) (between-groups comparison, p=0.019). Within each group, the postoperative IOP reduction was greater in eyes with higher baseline IOP (p<0.001). Medication burden decreased significantly in both groups, from 1.74 to 0.51 mean medications for iStent (70.7% reduction, p<0.0001), and 2.19 to 0.65 for iStent inject (70.3% reduction, p<0.0001). Both groups exhibited excellent safety. CONCLUSION iStent or iStent inject with phacoemulsification produced significant IOP and medication reductions, with effects enduring for two years. IOP reductions were greater for iStent inject than for iStent. Within each group, higher preoperative IOP was associated with greater postoperative IOP reduction.
Collapse
Affiliation(s)
| | | | | | - Alfredo Chaoubah
- Statistics Department, Federal University of Juiz De Fora, Juiz de Fora, MG, Brazil
| |
Collapse
|
11
|
Porter M, Garza A, Gallardo M. Excisional Goniotomy in Latino Patients with Open-Angle Glaucoma: Outcomes Through 24 Months. Clin Ophthalmol 2020; 14:3619-3625. [PMID: 33154621 PMCID: PMC7608600 DOI: 10.2147/opth.s271923] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 09/08/2020] [Indexed: 12/27/2022] Open
Abstract
Purpose To characterize the efficacy of combined phacoemulsification and excisional goniotomy with the Kahook Dual Blade (KDB-phaco) in eyes of Latino adults with cataract and open-angle glaucoma (OAG). Methods Health records of consecutive Latino patients undergoing KDB-phaco were retrospectively reviewed. Intraocular pressure (IOP) and IOP-lowering medication use were recorded at baseline and each postoperative visit through up to 24 months. Primary outcomes were reductions in IOP and medication use from baseline; secondary outcomes were the proportions of eyes achieving IOP reductions of ≥20% and medication reductions ≥1 medication from baseline. Subgroup analysis was conducted in eyes with high and low baseline IOP. Results Data from 44 eyes of 32 Latino patients with OAG were analyzed. Mean IOP was 17.8 (0.7) mmHg at baseline and postoperatively ranged from 12.4 to 13.8 mmHg (p≥0.0003), representing mean IOP reductions of 4.2–4.6 mmHg (19.7–23.1%). Mean medication was 1.5 (0.2) medications per eye at baseline and postoperatively ranged from 0.2 to 1.0 (p≥0.0061), representing mean medication reductions of 0.7–1.2 medications per eye (47.1–87.2%). In the low baseline IOP group (<18 mmHg), mean IOP was significantly reduced through Month 24 and medications through Month 12; in the high baseline IOP group (≥18 mmHg), IOP and medications were significantly reduced through Month 24. From Months 1–24, IOP reductions of ≥20% were achieved by 48.4–56.2% of eyes in the full cohort, by 20.0–33.3% in the low IOP group, and by 66.7–100% in the high IOP group; medication reductions of ≥1 medication were achieved by 72.0–95.6%, 64.7–94.2%, and 87.5–100% of eyes, respectively. Conclusion Combined KDB-phaco in eyes of Latino patients with glaucoma and cataract significantly lowers IOP and the need for IOP-lowering medications for up to 24 months and should be considered for such patients who warrant IOP reduction, medication reduction, or both.
Collapse
Affiliation(s)
- Matthew Porter
- Private Practice, El Paso Eye Surgeons, P.A., El Paso, Texas, USA.,Texas Tech University Health Sciences Center School of Medicine-Lubbock, Lubbock, TX, USA
| | - Arnulfo Garza
- Texas Tech University Paul L. Foster School of Medicine, Lubbock, TX, USA
| | - Mark Gallardo
- Private Practice, El Paso Eye Surgeons, P.A., El Paso, Texas, USA
| |
Collapse
|
12
|
Clement C, Howes F, Ioannidis AS, Shiu M, Manning D, Lusthaus J, Lim R, Skalicky SE, Goodwin T. Two-Year Multicenter Outcomes of iStent inject Trabecular Micro-Bypass Stents Combined with Phacoemulsification in Various Types of Glaucoma and Ocular Hypertension. Clin Ophthalmol 2020; 14:3507-3517. [PMID: 33149544 PMCID: PMC7604539 DOI: 10.2147/opth.s271646] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 10/15/2020] [Indexed: 12/11/2022] Open
Abstract
Purpose This multicenter study evaluated 2-year effectiveness and safety following implantation of two second-generation trabecular micro-bypass stents (iStent inject®) with phacoemulsification. Materials and Methods This was a retrospective study of iStent inject implantation with phacoemulsification by nine surgeons across Australia. Eyes had mild to advanced glaucoma (predominantly primary open-angle/POAG, appositional angle-closure/ACG, or normal-tension/NTG) or ocular hypertension (OHT), and cataract. Evaluations included intraocular pressure (IOP); medications; proportions of eyes with 0 or ≥2 medications, reduced/stable medications versus preoperative, and IOP ≤15 mmHg; visual acuity; cup-to-disc ratio (CDR); visual fields (VF); adverse events; and secondary surgery. Results A total of 340 eyes underwent surgery and had 24-month follow-up data. At 24 months, mean IOP decreased by 16% from 16.4±4.7 mmHg preoperatively to 13.7±3.1 mmHg (p<0.001), and 77% of eyes achieved IOP of ≤15 mmHg versus 49% preoperatively (p<0.001). Mean number of medications decreased by 67% to 0.49±0.95 versus 1.49±1.20 preoperatively (p<0.001), with 74% of eyes medication-free versus 25% preoperatively (p<0.001), and 14% of eyes on ≥2 medications versus 46% preoperatively (p<0.001). Medication burden was reduced or stable in 98% of eyes versus preoperative. Stratified analyses showed significant IOP and medication reductions across glaucoma subtypes (POAG, ACG, NTG, OHT): 13–22% for IOP (p<0.01 for all) and 62–100% for medication (p<0.001 for all). Favorable safety included few adverse events; stable CDR, VF, and visual acuity; and filtering surgery in only 8 eyes (2.4%) over 2 years. Conclusion This 340-eye multicenter dataset provides robust evidence of the safety and efficacy of iStent inject implantation with phacoemulsification, with significant and sustained IOP and medication reductions through 2 years. Results were similarly favorable across glaucoma subtypes (including POAG, ACG, NTG, OHT) and were attained across various glaucoma severities, clinical sites, and surgeons, highlighting the real-world versatility and utility of this treatment modality.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia.,Fairfield Eye Surgery, Fairfield, NSW, Australia.,Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia.,Eyehaus, Sydney, NSW, Australia
| | - Ridia Lim
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Hunter St. Eye Specialists, Parramatta, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
13
|
Nitta K, Yamada Y, Morokado S, Sugiyama K. iStent Trabecular Micro-Bypass Stent Implantation with Cataract Surgery in a Japanese Glaucoma Population. Clin Ophthalmol 2020; 14:3381-3391. [PMID: 33116389 PMCID: PMC7574908 DOI: 10.2147/opth.s274281] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 09/28/2020] [Indexed: 01/18/2023] Open
Abstract
Introduction This study assesses two-year efficacy and safety following implantation of a single trabecular micro-bypass stent (iStent®) with concomitant phacoemulsification cataract surgery in Japanese patients with open-angle glaucoma (OAG). Materials and Methods This retrospective, consecutive case series included eyes that underwent iStent implantation with phacoemulsification and were followed for 24 months postoperative. Efficacy and safety measures included intraocular pressure (IOP), number of glaucoma medications, adverse events, secondary surgeries, visual fields, and endothelial cell counts. Results Of 73 operated eyes, 53 eyes had 24 months of follow-up and are analyzed. Diagnoses included primary open-angle glaucoma (POAG, n=25), normal-tension glaucoma (NTG, n=16), and pseudoexfoliative glaucoma (PXG, n=12). At 24 months, mean IOP reduced by 18% to 13.6±3.0 mmHg versus 16.5±3.4 mmHg preoperatively (p<0.0001), and mean medication number reduced by 81% to 0.37±0.74 versus 1.96±0.98 preoperatively (p<0.0001). The percentage of medication-free eyes was 77% versus 0% preoperatively, and 81% of eyes had IOP ≤15 mmHg versus 42% preoperatively. Results were similarly favorable across glaucoma subtypes (POAG, NTG, PXG). Notably, mean IOP in NTG eyes decreased to 12.8±1.4 mmHg from 14.4±3.0 mmHg preoperatively (p=0.03), and medications decreased by 87% to 0.31±0.70 versus 2.38±0.72 preoperatively (p<0.0001). At 24 months, 81% of NTG eyes were medication-free (versus 0% preoperatively); 2 NTG eyes (13%) were on ≥2 medications (versus 100% preoperatively). Throughout the follow-up, visual fields and endothelial cell counts remained stable; 1 eye (1.9%) underwent filtration surgery. Discussion Favorable safety and significant IOP and mediation reductions were achieved through two years following iStent implantation with phacoemulsification in a Japanese population. These gains were achieved across all glaucoma subtypes (including POAG, NTG, PXG). Conclusion This real-world study supports the viability of iStent implantation to treat Japanese patients with glaucoma and shows that the benefits extend to those with NTG or PXG in addition to POAG.
Collapse
Affiliation(s)
- Koji Nitta
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Yutaro Yamada
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Satomi Morokado
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Kazuhisa Sugiyama
- Department of Ophthalmology, Kanazawa University, Kanazawa, Ishikawa Prefecture, Japan
| |
Collapse
|
14
|
Al-Holou SN, Havens SJ, Treadwell GG, Ghate D, Toris CB, Gulati V. Predictors of Intraocular Pressure Lowering after Phacoemulsification and iStent Implantation. Ophthalmol Glaucoma 2020; 4:139-148. [PMID: 32931948 DOI: 10.1016/j.ogla.2020.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 08/05/2020] [Accepted: 09/09/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To explore the demographic and clinical variables associated with intraocular pressure (IOP) lowering after cataract extraction (CE) alone or CE in combination with the iStent (Glaukos Corporation) placement (CE+IS). DESIGN Retrospective data extraction and survival analysis of consecutive patients identified over a 2-year period. PARTICIPANTS Patients with mild to moderate glaucoma who underwent CE (48 eyes of 32 patients) or CE+IS (61 eyes of 37 patients) were analyzed. METHODS Inability to reduce the number of medications or the IOP by at least 20% compared with baseline on 2 consecutive visits was considered surgical failure. Using Cox proportional hazards models, survival analysis was performed, and demographic and clinical variables were evaluated as risk factors. MAIN OUTCOME MEASURES Time to failure after surgical procedure. RESULTS CE+IS had lower odds of failure than CE alone (hazard ratio [HR], 2.01; P = 0.047). In White patients, CE+IS showed greater odds of success compared with CE alone (HR, 2.86; P = 0.007). For non-White patients, no difference was found in the outcomes for the 2 procedures (HR, 0.59; P = 0.48). In the multivariate analysis, non-White race (HR, 8.75; P = 0.0002) and longer axial length (HR, 1.61; P = 0.03) were associated with greater hazard of failure after CE+IS. In the CE group, greater odds of failure were associated with steeper corneal curvature (HR, 1.74; P = 0.008), shallower anterior chamber (HR, 0.22; P = 0.008), and longer axial length (HR, 1.58; P = 0.01). CONCLUSIONS Addition of the iStent to CE improved the duration of IOP lowering in White patients, but not in non-White patients. Associations between IOP lowering after CE and biometric parameters may allow for leveraging these clinical parameters for better case selection for these procedures.
Collapse
Affiliation(s)
- Shaza N Al-Holou
- Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska; Wills Eye Hospital, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Shane J Havens
- Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska; Eye Consultants, PC, Omaha, Nebraska
| | - Gillian G Treadwell
- Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska; Wake Forest School of Medicine, Department of Ophthalmology, Winston-Salem, North Carolina
| | - Deepta Ghate
- Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska
| | - Carol B Toris
- Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska
| | - Vikas Gulati
- Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska.
| |
Collapse
|
15
|
Schweitzer JA, Hauser WH, Ibach M, Baartman B, Gollamudi SR, Crothers AW, Linn JE, Berdahl JP. Prospective Interventional Cohort Study of Ocular Surface Disease Changes in Eyes After Trabecular Micro-Bypass Stent(s) Implantation (iStent or iStent inject) with Phacoemulsification. Ophthalmol Ther 2020; 9:941-953. [PMID: 32789800 PMCID: PMC7708605 DOI: 10.1007/s40123-020-00290-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Indexed: 01/23/2023] Open
Abstract
Introduction This study sought to assess ocular surface disease changes following cataract surgery combined with trabecular micro-bypass stent(s) implantation (iStent or iStent inject). Methods This prospective interventional single-arm clinical trial enrolled 47 eyes with mild-to-moderate open-angle glaucoma (OAG) on 1–4 glaucoma medications who underwent phacoemulsification and trabecular micro-bypass stent(s) implantation. Key glaucoma and ocular surface data through 3 months postoperatively included the Ocular Surface Disease Index score (OSDI), corneal/conjunctival staining (Oxford Schema), fluorescein tear break-up time (FTBUT), conjunctival hyperemia (Efron Scale), glaucoma medications, and intraocular pressure (IOP). Results Mean OSDI scores improved from 40.1 ± 21.6 (severe) preoperatively to 17.5 ± 15.3 (mild) at 3 months (p < 0.0001). While 73% of eyes had moderate or severe OSDI scores preoperatively, 29% had such scores at 3 months, and the OSDI score was normal in 57% of eyes versus 9% preoperatively. Mean FTBUT increased from 4.3 ± 2.4 s preoperatively to 6.4 ± 2.5 s at 3 months (p < 0.0001); mean Oxford corneal/conjunctival staining reduced from 1.4 ± 1.0 preoperatively to 0.4 ± 0.6 at 3 months (p < 0.0001); mean Efron conjunctival hyperemia score reduced from 1.4 ± 0.7 preoperatively to 1.2 ± 0.6 at 3 months (p = 0.118). The number of glaucoma medications decreased from 1.5 ± 0.9 to 0.6 ± 0.8 mean medications (60% reduction, p < 0.0001), with all eyes maintaining or reducing medications versus preoperatively and 55% of eyes becoming medication-free (versus 0% preoperatively). Mean IOP reduced from 17.4 ± 4.2 mmHg to 14.5 ± 3.2 mmHg (p < 0.0001). The safety profile was excellent. Conclusion Implantation of trabecular micro-bypass stent(s) (iStent or iStent inject) with cataract surgery produced significant improvements in ocular surface health, alongside significant reductions in IOP and medications. Trial registration ClinicalTrials.gov identifier, NCT04452279.
Collapse
|
16
|
Berdahl J, Voskanyan L, Myers JS, Katz LJ, Samuelson TW. iStent
inject trabecular micro‐bypass stents with topical prostaglandin as standalone treatment for open‐angle glaucoma: 4‐year outcomes. Clin Exp Ophthalmol 2020; 48:767-774. [DOI: 10.1111/ceo.13763] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 04/01/2020] [Accepted: 04/09/2020] [Indexed: 01/22/2023]
Affiliation(s)
- John Berdahl
- Vance Thompson Vision Sioux Falls South Dakota USA
| | | | - Jonathan S. Myers
- Wills Eye HospitalJefferson Medical College Philadelphia Pennsylvania USA
| | - L. Jay Katz
- Wills Eye HospitalJefferson Medical College Philadelphia Pennsylvania USA
- Glaukos Corporation San Clemente California USA
| | | |
Collapse
|
17
|
Gillmann K, Mansouri K. Minimally Invasive Glaucoma Surgery: Where Is the Evidence? Asia Pac J Ophthalmol (Phila) 2020; 9:203-214. [PMID: 32501895 PMCID: PMC7299223 DOI: 10.1097/apo.0000000000000294] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 04/04/2020] [Indexed: 12/12/2022] Open
Abstract
PURPOSE The last decade has witnessed an unprecedented growth in glaucoma treatment options through the introduction of minimally invasive glaucoma surgeries (MIGS). The aim of the present review is to provide an understanding of the currently available MIGS and to examine what data are currently available to guide treatment choice. DESIGN Meta-analysis and systematic review of randomized and non-randomized control trials. METHODS Out of 2567 articles identified, a total of 77 articles were retained for analysis, including 28 comparative studies and 12 randomized control trials. Overall, 7570 eyes were included. When data permitted, the weighted mean difference in intraocular pressure reduction was calculated for comparison purposes. RESULTS Weighted mean intraocular pressure reductions from all analyzed studies were: 15.3% (iStent), 29.1% (iStent inject), 36.2% (ab interno canaloplasty), 34.4% (Hydrus), 36.5% (gonioscopically-assisted transluminal trabeculotomy), 24.0% (trabectome), 25.1% (Kahook dual blade), 30.2% (Cypass), 38.8% (XEN), and 50.0% (Preserflo). CONCLUSIONS One of the advantages of the heterogenous range of available MIGS options is the chance to tailor therapy in an individualized manner. However, high-quality data are required to make this choice more than an educated guess. Overall, this review confirms the efficiency of assessed MIGS compared with standalone phacoemulsification, but it highlights that only few studies compare different MIGS techniques and even fewer assess MIGS against criterion standard treatments. Current evidence, while non-negligible, is mostly limited to heterogenous nonrandomized studies and uncontrolled retrospective comparisons, with few quality randomized control trials. We suggest that future research should be comparative and include relevant comparators, standardized to report key outcome features, long-term to assess sustainability and late complications, and ideally randomized.
Collapse
Affiliation(s)
- Kevin Gillmann
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
| | - Kaweh Mansouri
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
- Department of Ophthalmology, University of Colorado School of Medicine, Denver, CO, USA
| |
Collapse
|
18
|
Pantalon AD, Barata ADDO, Georgopoulos M, Ratnarajan G. Outcomes of phacoemulsification combined with two iStent inject trabecular microbypass stents with or without endocyclophotocoagulation. Br J Ophthalmol 2020; 104:1378-1383. [PMID: 31980421 DOI: 10.1136/bjophthalmol-2019-315434] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 01/09/2020] [Accepted: 01/13/2020] [Indexed: 11/04/2022]
Abstract
AIM Comparing outcomes after combined phacoemulsification, two iStents insertion and endocyclophotocoagulation (ECP) versus phacoemulsification-iStents alone. METHODS This is a longitudinal retrospective 12 months study in eyes with ocular hypertension or early-to-moderate open angle glaucoma. Level of disease, intraocular pressure (IOP) and tolerance of glaucoma medication were considered before planning surgery. Best-corrected visual acuity (BCVA-logMAR), IOP (mm Hg), number of medications were assessed at baseline, week 1, week 5, month 3, 6, 12 postop. MAIN OUTCOME percentage (%) in IOP reduction at 12 months vs medicated baseline. SECONDARY OUTCOMES absolute values of IOP/medication reduction, BCVA and postop complications. RESULTS The ICE2 (two iStents-cataract extraction-ECP) group included 63 eyes and Phaco-iStent group included 46 eyes. Baseline IOP was higher in the ICE2 than phaco-iStent group (19.97±4.31 mm Hg vs 17.63±3.86 mm Hg, p=0.004) and mean deviation was lower (-7.20±2.58 dB vs -4.94±4.51 dB, p=0.037). Number of medications were comparable at baseline: 2.22±1.06 (ICE2) vs 2.07±1.02 (phaco-iStent), p=0.442. At month 12 postop, IOP in the ICE2 group decreased 35% from baseline vs 21% in the phaco-iStent group (p=0.03); absolute IOP reduction was significantly lower than baseline in each group (p<0.001), yet final IOP was lower in the ICE2 group than phaco-iStent group (13.05±2.18 mm Hg vs 14.09±1.86 mm Hg, p=0.01). Similar results were found for glaucoma medication (1.24±1.05 in ICE2 group vs 1.39±1.03 in phaco-iStent group, p=0.01). Final BCVA was 0.11±0.18 (phaco-iStent group) vs 0.08±0.08 (ICE2 group), p=0.309. Safety outcomes were comparable between groups. CONCLUSION ICE2 procedure offers better results in IOP/medication reduction at 12 months than phacoemulsification-iStents alone.
Collapse
Affiliation(s)
- Anca Delia Pantalon
- Eye Unit and Eye Bank, Queen Victoria Hospital NHS Foundation Trust, East Grinstead, UK.,Ophthalmology, "St. Spiridon" University Hospital, Iasi, Romania
| | - Andre Diogo De Oliveira Barata
- Eye Unit and Eye Bank, Queen Victoria Hospital NHS Foundation Trust, East Grinstead, UK.,Ophthalmology, Santa Maria Central Hospital, Lisbon, Portugal
| | - Minas Georgopoulos
- Eye Unit and Eye Bank, Queen Victoria Hospital NHS Foundation Trust, East Grinstead, UK.,Ophthalmology, East Surrey Hospital, Redhill, UK
| | - Gokulan Ratnarajan
- Eye Unit and Eye Bank, Queen Victoria Hospital NHS Foundation Trust, East Grinstead, UK
| |
Collapse
|