1
|
Blot S, Filattre M, Fauviaux E, Jany B, Tran THC. [Visual performance after bilateral implantation of an extended depth of focus intraocular lens, AE2UV/ZOE, targeted for mini-monovision]. J Fr Ophtalmol 2025; 48:104475. [PMID: 40086044 DOI: 10.1016/j.jfo.2025.104475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Revised: 10/02/2024] [Accepted: 10/31/2024] [Indexed: 03/16/2025]
Abstract
OBJECTIVE To evaluate the impact of mini-monovision on visual performance after bilateral implantation of AE2UV/ZOE™ extended depth of focus IOLs. METHODS This is a single-center prospective study including 60 patients who underwent bilateral cataract surgery. Patients were divided into 2 groups: with mini-monovision targeted for group 1 and emmetropia targeted for group 2. Distance, intermediate and near vision, spectacle independence and patient satisfaction were assessed 1 month after surgery. RESULTS The mini-monovision group included 29 patients and the emmetropia group 31 patients. Mean uncorrected intermediate (0.08 vs. 0.19 logMAR, P=0.043) and near (0.29 vs. 0.53, P<0.001) visual acuity in the mini-monovision group were significantly better. Binocular distance visual acuity was less than 0.0 logMAR for both groups, without statistically significant difference. The level of spectacle dependence is statistically higher in the emmetropia group for intermediate and near distance activities (43% vs. 21%; 93% vs. 43% respectively; P<0.05). Patient satisfaction scores for uncorrected near vision were better in the mini-monovision group (6.25 vs. 3.17; P<0.001). CONCLUSION The mini-monovision approach in bilateral A2E/ZOE™ IOL implantation enables better visual performance in intermediate and near vision, without degradation of distance vision, with high levels of patient satisfaction.
Collapse
Affiliation(s)
- S Blot
- CHU d'Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80000 Amiens, France.
| | - M Filattre
- CHU d'Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80000 Amiens, France
| | - E Fauviaux
- CHU d'Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80000 Amiens, France
| | - B Jany
- CHU d'Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80000 Amiens, France
| | - T H C Tran
- CHU d'Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80000 Amiens, France.
| |
Collapse
|
2
|
Kim B, Son HS, Khoramnia R, Auffarth GU, Choi CY. Comparison of clinical outcomes between different combinations of hybrid multifocal, extended-depth-of-focus and enhanced monofocal intraocular lenses. Br J Ophthalmol 2025; 109:565-571. [PMID: 39658143 DOI: 10.1136/bjo-2024-325181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 11/09/2024] [Indexed: 12/12/2024]
Abstract
PURPOSE To compare clinical outcomes of bilateral implantation of hybrid multifocal intraocular lenses (IOLs) versus mix-and-match implantation of hybrid multifocal and extended-depth-of-focus (EDOF) versus mix-and-match implantation of hybrid multifocal and enhanced monofocal IOLs. METHODS Patients with bilateral age-related cataract were randomised in one of three groups: group 1, bilateral hybrid multifocal IOL; group 2, EDOF in the dominant eye, hybrid multifocal in the non-dominant eye; group 3, enhanced monofocal in the dominant eye, hybrid multifocal in the non-dominant eye. Assessments at 6 months postoperatively included monocular and binocular uncorrected distance visual acuity (UDVA), intermediate (UIVA) and near distance (UNVA) at 40 and 33 cm, defocus curves, contrast sensitivity (CS), reading speed and questionnaires on quality of vision and dysphotopsia. RESULTS 75 patients (25 per group) were enrolled. There were no statistically significant differences in binocular UDVA and UNVA between groups (p>0.05); binocular UIVA was better for group 1 and 2 versus group 3 (p=0.030). Binocular uncorrected defocus curve showed better performance for group 1 compared with group 3 from -2.00 to -3.50 D. Significantly higher reading speed was measured for Jaeger 1 font in group 1. There were no differences in CS between groups, but higher incidence of starbursts in group 1 and higher need for near spectacles in group 3. CONCLUSION Bilateral hybrid multifocal IOL implantation resulted in better near vision, but higher rates of photic phenomena compared with the mix-and-match groups. Combinations of IOLs may allow surgeons to fine-tune for individual patient's needs.
Collapse
Affiliation(s)
- Bokyung Kim
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Hyeck-Soo Son
- Department of Ophthalmology, International Vision Correction Research Centre, University Hospital of Heidelberg, Heidelberg, Germany
| | - Ramin Khoramnia
- Department of Ophthalmology, International Vision Correction Research Centre, University Hospital of Heidelberg, Heidelberg, Germany
| | - Gerd U Auffarth
- Department of Ophthalmology, International Vision Correction Research Centre, University Hospital of Heidelberg, Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| |
Collapse
|
3
|
Algorinees RM, Alshammari BJ, Albalawi MA, Almozaini KH, Alharbi TF, Alshammari TA, Alghaslan MA, Almansour RN. Assessment and Knowledge of Long-Term Steroid Use and Its Related Cataract & Glaucoma Development Among Hail Residents. Clin Ophthalmol 2025; 19:585-597. [PMID: 39990743 PMCID: PMC11846618 DOI: 10.2147/opth.s510432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2024] [Accepted: 02/10/2025] [Indexed: 02/25/2025] Open
Abstract
Purpose This study evaluated the prevalence of steroid use and public awareness of its ocular complications, including cataracts and glaucoma, in Hail, Saudi Arabia. Methods A descriptive cross-sectional study was conducted in Saudi Arabia's Hail region from September 2024 to November 2024, targeting eligible and accessible residents aged 18 years or older. Data was collected using a pre-structured online questionnaire developed by the researchers. The final version was independently reviewed and distributed online to eligible applicants. The collected data included socio-demographic information, medical history, personal habits, and knowledge of potential associations between steroid use and eye diseases. Data analysis was done using SPSS version 26 based on descriptive statistics and relations using the Pearson X2 test and exact probability test. Results The study surveyed young adults aged 18 years or more, with 51.8% being male. Most participants (74.5%) had never used steroids. Eye drops were the most common, followed by topical creams. 30.8% of participants had good knowledge about long-term steroid use with cataract development, while 21% had a good knowledge level for steroid use and glaucoma development. In total, 24.7% had good knowledge about eye diseases. Conclusion A study in Hail, Saudi Arabia reveals a significant lack of public knowledge about the long-term use of steroids and associated ocular risks, particularly cataracts and glaucoma. Despite never using steroids, those who have used them often prefer short-term treatments. The study recommends improved patient education, health interventions, and regulation of over-the-counter steroids usage, especially for younger populations and those without healthcare backgrounds.
Collapse
Affiliation(s)
- Rakan Mosa Algorinees
- Department of Ophthalmology, College of Medicine, University of Hail, Hail, Saudi Arabia
| | | | - Mansour Ahmed Albalawi
- Department of Ophthalmology, College of Medicine, University of Hail, Hail, Saudi Arabia
| | | | - Talal Fahad Alharbi
- Department of Ophthalmology, College of Medicine, University of Hail, Hail, Saudi Arabia
| | - Turki Ali Alshammari
- Department of Ophthalmology, College of Medicine, University of Hail, Hail, Saudi Arabia
| | - Manar Ali Alghaslan
- Department of Ophthalmology, College of Medicine, University of Hail, Hail, Saudi Arabia
| | - Rana Nasser Almansour
- Department of Ophthalmology, College of Medicine, University of Hail, Hail, Saudi Arabia
| |
Collapse
|
4
|
Xiong T, Chen H, Fan W. Comparison of bilateral implantation of an extended depth of focus lenses and a blend approach of extended depth of focus lenses and bifocal lenses in cataract patients. BMC Ophthalmol 2023; 23:476. [PMID: 37990306 PMCID: PMC10664382 DOI: 10.1186/s12886-023-03228-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Accepted: 11/16/2023] [Indexed: 11/23/2023] Open
Abstract
BACKGROUND To compare the visual outcomes, spectacle independent rate and stereopsis in patients who underwent bilateral implantation of extended depth of focus (EDOF) intraocular lens (IOL), or a blend approach of EDOF and bifocal IOL. METHODS A total of 60 cataract patients, who were scheduled for phacoemulsification and intraocular lens implantation in both eyes in West China Hospital of Sichuan University, were enrolled and divided into Micro monovision group(-0.5D~-1.0D), Non-micro monovision group (< 0.5D) with Symfony IOL, and Mixed group with Symfony and ZMB00 IOLs. Three months postoperatively, we compared the visual acuity, modulation transfer function (MTF), defocus curve, stereopsis, spectacle independence, and photic phenomena among the three groups. RESULTS Compared to the Non-micro monovision group (UNVA: 0.07 ± 0.04), Micro monovision group (UNVA: 0.00 ± 0.07, P < 0.001) and Mixed group (UNVA: -0.02 ± 0.06, P < 0.001) showed improvement in binocular uncorrected near visual acuity (UNVA). Additionally, Mixed group exhibited lower MTF10 (MTF10: 0.38 ± 0.24) and point spread function (PSF: 0.192 ± 0.269) results in their non-dominant eye compared to both Micro monovision group (MTF10: 0.56 ± 0.21, P = 0.027; PSF: 0.417 ± 0.282, P = 0.034) and Non-micro monovision group (MTF10: 0.55 ± 0.19, P = 0.038; PSF: 0.408 ± 0.285, P = 0.003). Spectacle independence for near vision were higher in both the Micro monovision (45%) and Mixed (55%) group compared to the Non-micro monovision group (40%). The Mixed group also reported higher incidence of photic phenomena (25%). However, there were no significant differences in stereoscopic function among the three groups. CONCLUSION Both micro monovision and mix-and-match methods can help patients to obtain better visual outcomes at different distances. Mix-and-match method has better near visual acuity, while micro monovision method has better intermediate visual acuity. Non-micro monovision methods will affect patients' near vision outcomes. Binocularly implanted EDOF IOL has better contrast sensitivity. CLINICAL TRIAL REGISTRATION Registration date:11/07/2023. TRIAL REGISTRATION NUMBER ChiCTR2300073433. TRIAL REGISTRY West China Hospital of Sichuan University retrospectively registered.
Collapse
Affiliation(s)
- Tianxu Xiong
- Department of Ophthalmology, West China Hospital of Sichuan University, 610041, Chengdu, Sichuan Province, China
| | - Hao Chen
- Department of Ophthalmology, West China Hospital of Sichuan University, 610041, Chengdu, Sichuan Province, China
| | - Wei Fan
- Department of Ophthalmology, West China Hospital of Sichuan University, 610041, Chengdu, Sichuan Province, China.
| |
Collapse
|
5
|
Lan Q, Xu F, Sun T, Zeng S, Liu Y, Yang T, Li Y, Yao G, Ma B, Tao L, Ma B, Xiao X, Li M, Qi H. Comparison of binocular visual quality in six treatment protocols for bilateral cataract surgery with presbyopia correction: a prospective two-center single-blinded cohort study. Ann Med 2023; 55:2258894. [PMID: 37734409 PMCID: PMC10515669 DOI: 10.1080/07853890.2023.2258894] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 09/07/2023] [Indexed: 09/23/2023] Open
Abstract
OBJECTIVE To compare the postoperative binocular visual quality in six treatment protocols for bilateral age-related cataract surgery with presbyopia correction for clinical decisions. MATERIALS AND METHODS In this prospective two-center single-blinded cohort study, participants from North or South China who underwent bilateral phacoemulsification and intraocular lens implantation were divided into six protocols: monovision, diffractive bifocal, mixed, refractive bifocal, trifocal, and micro-monovision extended range of vision (EROV). Binocular visual quality was evaluated at 3 months postoperatively, including binocular uncorrected full-range visual acuity, binocular defocus curves (depth of focus [DoF] and area under the curve [AUC]), binocular visual function (fusion function and stereopsis), binocular subjective spectacle independence rates, visual analog scale (VAS) of overall satisfaction, 25-item visual function questionnaire (VFQ-25), and binocular dysphotopsia symptoms. RESULTS Of the 300 enrolled patients, 272 (90.7%; 544 eyes) were analyzed. The trifocal protocol showed excellent binocular full-range visual acuity and the best performance for most DoFs and AUCs. The monovision protocol presented the worst binocular visual quality in most perspectives, especially in convergence, distance, and near stereopsis (p < 0.001). The full-range subjective spectacle independence rates were sorted from highest to lowest as follows: trifocal (84.8%), refractive bifocal (80.9%), EROV (80.0%), mixed (73.3%), diffractive bifocal (65.2%), and monovision (32.6%) protocols, with no statistically significant differences between the former five protocols (p > 0.05). The EROV protocol achieved the highest VAS and VFQ-25 scores. The incidence of postoperative binocular dysphotopsia symptoms was comparable in all protocols. CONCLUSIONS The trifocal protocol showed the best performance, and the monovision protocol presented the worst performance in most perspectives of binocular visual quality for presbyopia correction. The refractive bifocal, mixed, or EROV protocols can provide an approximate performance as a trifocal protocol. Ophthalmologists can customize therapies using different protocols.
Collapse
Affiliation(s)
- Qianqian Lan
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- Guangxi Academy of Medical Sciences and Department of Ophthalmology, The People’s Hospital of Guangxi Zhuang Autonomous Region and Guangxi Key Laboratory of Eye Health and Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology (The People’s Hospital of Guangxi Zhuang Autonomous Region), Institute of Ophthalmic Diseases, Nanning, China
| | - Fan Xu
- Guangxi Academy of Medical Sciences and Department of Ophthalmology, The People’s Hospital of Guangxi Zhuang Autonomous Region and Guangxi Key Laboratory of Eye Health and Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology (The People’s Hospital of Guangxi Zhuang Autonomous Region), Institute of Ophthalmic Diseases, Nanning, China
| | - Tong Sun
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Siming Zeng
- Guangxi Academy of Medical Sciences and Department of Ophthalmology, The People’s Hospital of Guangxi Zhuang Autonomous Region and Guangxi Key Laboratory of Eye Health and Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology (The People’s Hospital of Guangxi Zhuang Autonomous Region), Institute of Ophthalmic Diseases, Nanning, China
| | - Yiyun Liu
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Tingting Yang
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Yaxin Li
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Gang Yao
- Guangxi Academy of Medical Sciences and Department of Ophthalmology, The People’s Hospital of Guangxi Zhuang Autonomous Region and Guangxi Key Laboratory of Eye Health and Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology (The People’s Hospital of Guangxi Zhuang Autonomous Region), Institute of Ophthalmic Diseases, Nanning, China
| | - Baikai Ma
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Liyuan Tao
- Research Center of Clinical Epidemiology, Peking University Third Hospital, Beijing, China
| | - Boping Ma
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Xin Xiao
- Guangxi Academy of Medical Sciences and Department of Ophthalmology, The People’s Hospital of Guangxi Zhuang Autonomous Region and Guangxi Key Laboratory of Eye Health and Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology (The People’s Hospital of Guangxi Zhuang Autonomous Region), Institute of Ophthalmic Diseases, Nanning, China
| | - Min Li
- Guangxi Academy of Medical Sciences and Department of Ophthalmology, The People’s Hospital of Guangxi Zhuang Autonomous Region and Guangxi Key Laboratory of Eye Health and Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology (The People’s Hospital of Guangxi Zhuang Autonomous Region), Institute of Ophthalmic Diseases, Nanning, China
| | - Hong Qi
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| |
Collapse
|
6
|
Tomagova N, Elahi S, Vandekerckhove K. Clinical Outcomes of a New Non-Diffractive Extended Depth-of-Focus Intraocular Lens Targeted for Mini-Monovision. Clin Ophthalmol 2023; 17:981-990. [PMID: 37007049 PMCID: PMC10053890 DOI: 10.2147/opth.s405267] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 03/13/2023] [Indexed: 04/04/2023] Open
Abstract
Purpose To assess visual acuity, binocular defocus curve, spectacle independence, and photic phenomena after bilateral same-day cataract surgery with implantation of an extended depth-of-focus intraocular lens (IOL) with mini-monovision. Methods Single-center retrospective study including 124 eyes from 62 patients who underwent bilateral implantation of an isofocal EDOF lens [Isopure® (BVI)] with mini-monovision (-0.50 D). Refraction, visual acuity at different distances, binocular defocus curves, spectacle independence, and subjective ratings of picture-referenced photic phenomena were assessed one to two months postoperatively. Results The mean postoperative refractive spherical equivalent was -0.15±0.41D in the dominant eyes and -0.46±0.35D in the mini-monovision eyes (p<0.01). Overall, 98.4% and 87.7% of the eyes were within ±1.00D and ±0.50D of the target refraction, respectively. Postoperative monocular corrected distance visual acuity was -0.04±0.07 logMAR. Binocular uncorrected visual acuity was -0.02±0.07, 0.13±0.11and 0.40±0.20 logMAR for far, intermediate and near, respectively. At the visual acuity threshold of 0.20 logMAR (or better) the defocus curve ranged from -1.6D to +0.9D. Reported spectacle-independence was 96% for far distance, 95% for intermediate, and 34% for near. Five percent of patients reported halos, 16% starburst, and 16% glare. Only 7% of all patients considered them bothersome. Conclusion In patients undergoing same-day bilateral cataract surgery, an isofocal EDOF lens provided an extended range of functional vision, up to 63 cm, resulting in useful uncorrected near vision, good uncorrected intermediate vision, and excellent uncorrected distance vision. Subjective patient satisfaction in terms of spectacle independence and photic phenomena was high.
Collapse
Affiliation(s)
- Nikola Tomagova
- Clinical Study Department, Vista Alpina Eye Clinic, Visp, Switzerland
| | - Sina Elahi
- Clinical Study Department, Vista Alpina Eye Clinic, Visp, Switzerland
| | - Kristof Vandekerckhove
- Clinical Study Department, Vista Alpina Eye Clinic, Visp, Switzerland
- Correspondence: Kristof Vandekerckhove, Clinical Study Department, Vista Alpina Eye Clinic, Bahnhofplatz 1a, Visp, 3930, Switzerland, Tel +41279467000, Email
| |
Collapse
|
7
|
Cost-Effectiveness of Presbyopia Correction Among Seven Strategies of Bilateral Cataract Surgery Based on a Prospective Single-Blind Two-Center Trial in China. Ophthalmol Ther 2022; 11:2067-2082. [PMID: 36071311 DOI: 10.1007/s40123-022-00562-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Accepted: 08/22/2022] [Indexed: 10/14/2022] Open
Abstract
INTRODUCTION The aim of this study was to explore a method to rank the cost-effectiveness of presbyopia correction in diverse strategies of bilateral cataract surgery to provide references for healthcare policymakers in rationalizing resource utilization and surgeons in customizing patient management. METHODS The cost-effectiveness analysis based on a prospective single-blind two-center clinical trial included seven strategies in bilateral cataract surgery: monofocal, monovision, diffractive bifocal, blended, refractive bifocal, trifocal, and extended depth of focus (EDOF) strategies. The effectiveness according to the objective spectacle independence rate (hereafter "rate", a novel indicator defined as the proportion of patients with binocular uncorrected distance, intermediate and near visual acuity all better than 0.1 logMAR, logarithm of the minimum angle of resolution), costs, average cost-effectiveness ratios (ACERs, $/1% rate), and incremental cost-effectiveness ratios (ICERs, $/1% incremental rate) were estimated. RESULTS In 194 participants (388 eyes), the trifocal strategy achieved the highest rate [93.10% (95% confidence interval (CI) 83.8-102.35%)]. The refractive bifocal strategy had the minimum ACER [$45.54/1% rate (95% CI 34.57-56.50)], followed by the blended [$59.10/1% rate (95% CI 31.72-86.48)], diffractive bifocal [$69.06/1% rate (95% CI 30.89-107.21)], EDOF [$72.85/1% rate (95% CI 52.02-93.70)], trifocal [$93.01/1% rate (95% CI 83.23-102.79)], monovision [$136.83/1% rate (95% CI - 55.40 to 329.14)], and monofocal [$264.45/1% rate (95% CI - 97.45 to 626.55)] strategies. Compared with the refractive bifocal strategy, the probabilities that the trifocal strategy (ICER $289.74/1% incremental rate) is very cost-effective and cost-effective were 81.7% and 93.2%, respectively, at the wiliness-to-pay threshold of one and three times China's annual disposable income per capita in 2021 per 10% incremental rates. CONCLUSIONS Cost-effectiveness analysis with ACER and ICER according to objective spectacle independence rate is a helpful tool to identify highly cost-effective presbyopia-correcting strategies in cataract surgery for clinical and policy decisions. TRIAL REGISTRATION Clinicaltrials.gov (NCT04265846).
Collapse
|
8
|
Sevik MO, Akkaya Turhan S, Toker E. Clinical outcomes with a low add multifocal and an extended depth of focus intraocular lenses both implanted with mini-monovision. Eye (Lond) 2022; 36:1168-1177. [PMID: 34117383 PMCID: PMC9151652 DOI: 10.1038/s41433-021-01600-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Revised: 05/05/2021] [Accepted: 05/07/2021] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVES To compare the visual acuity, contrast sensitivity (CS), spectacle needs, photic phenomena, and quality of life parameters of patients bilaterally implanted with a low add multifocal (MIOL) or an extended depth of focus (EDOF) intraocular lens (IOL), both with intended mini-monovision. METHODS In this prospective, randomized, comparative study, patients were randomized to receive either Tecnis +2.75 D (ZKB00) (MIOL Group, n = 15) or Tecnis Symfony (ZXR00) (EDOF Group, n = 14) for bilateral implantation with mini-monovision (-0.50 D). Binocular logMAR uncorrected visual acuities (UVA), monocular defocus curves, CS with CSV 1000-E, and Pelli-Robson Test (PRT), spectacle needs and quality of life parameters with NEI RQL-42 questionnaire were evaluated at postoperative 1, 3, and 6 months. RESULTS Results of MIOL and EDOF Groups at postoperative month 6 are as follows: distance (6 m) UVA -0.03 ± 0.05 and -0.05 ± 0.06 (p = 0.938), intermediate (60 cm) UVA, 0.04 ± 0.08 and -0.03 ± 0.07 (p = 0.046); near (40 cm) UVA, 0.22 ± 0.08 and 0.15 ± 0.07 (p = 0.046); near spectacle needs, 26.7% and 14.3% (p > 0.05), respectively. Better visual acuity was achieved in the EDOF Group between the defocus range of -0.50 and -1.75 D (p < 0.05). No significant difference was found regarding photic phenomena and CS evaluated with CSV 1000-E between the two IOL groups at 6 months after surgery (otherwise there are differences at 1 and 3 months in favor of EDOF). However, EDOF Group performed better in mesopic CS evaluated with PRT (p < 0.05). CONCLUSIONS When implanted with mini-monovision better binocular uncorrected visual performance at intermediate and near distances achieved with EDOF than low add MIOL.
Collapse
Affiliation(s)
- Mehmet Orkun Sevik
- Department of Ophthalmology, Marmara University School of Medicine, Istanbul, Turkey.
| | - Semra Akkaya Turhan
- grid.16477.330000 0001 0668 8422Department of Ophthalmology, Marmara University School of Medicine, Istanbul, Turkey
| | - Ebru Toker
- grid.16477.330000 0001 0668 8422Department of Ophthalmology, Marmara University School of Medicine, Istanbul, Turkey
| |
Collapse
|
9
|
Nowik KE, Nowik K, Kanclerz P, Szaflik JP. Clinical Performance of Extended Depth of Focus (EDOF) Intraocular Lenses – A Retrospective Comparative Study of Mini Well Ready and Symfony. Clin Ophthalmol 2022; 16:1613-1621. [PMID: 35651536 PMCID: PMC9150758 DOI: 10.2147/opth.s341698] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Accepted: 04/14/2022] [Indexed: 11/27/2022] Open
Abstract
Purpose Extended depth of focus intraocular (EDOF) IOLs form a bridge between single- and multifocal IOL design. This study aimed to compare clinical outcomes obtained after implanting two different optical designs of EDOF IOLs: the Mini Well Ready (SIFI Medtech, Catania, Italy) and Tecnis Symfony (Abbott Laboratories, Illinois, USA). Methods The retrospective observational study included 61 patients (122 eyes) who underwent bilateral implantation of the Mini Well Ready IOL (32 patients) or the Tecnis Symfony IOL (29 patients). The following preoperative and postoperative parameters were evaluated: spherical equivalent, anterior astigmatism, pupil size, monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), monocular and binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA). In the 6 months postoperative period, defocus curve, contrast sensitivity, photopic phenomena, and posterior capsule opacification were assessed. Results The patients receiving the Tecnis Symfony had slightly better monocular and binocular UDVA and CDVA than with the Mini Well Ready IOL, the differences were not statistically significant. Whereas the UIVA, DCIVA, UNVA, DCNVA, UNVA and DCNVA values were higher in the Mini Well Ready group, the differences were not significant. There were no significant between-group differences regarding the defocus curve for the vast majority of tested vergences. Dysphotopsias postoperatively were assessed at 6 months. Conclusion Patients receiving both the Mini Well Ready and Symfony IOLs had excellent visual acuity outcomes and spectacle independence.
Collapse
Affiliation(s)
- Katarzyna Ewa Nowik
- Department of Ophthalmology, Public Ophthalmic Clinical Hospital (SPKSO), Medical University of Warsaw, Warsaw, Poland
- Correspondence: Katarzyna Ewa Nowik, Tel +48 509 873 680, Email
| | - Kamil Nowik
- Department of Ophthalmology, Public Ophthalmic Clinical Hospital (SPKSO), Medical University of Warsaw, Warsaw, Poland
| | - Piotr Kanclerz
- Department of Ophthalmology, Hygeia Clinic, Gdańsk, Poland
- Helsinki Retina Research Group, University of Helsinki, Helsinki, Finland
| | - Jacek Paweł Szaflik
- Department of Ophthalmology, Public Ophthalmic Clinical Hospital (SPKSO), Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
10
|
Quantitative assessment of photic phenomena in the presbyopia-correcting intraocular lens. PLoS One 2021; 16:e0260406. [PMID: 34851975 PMCID: PMC8635348 DOI: 10.1371/journal.pone.0260406] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 11/09/2021] [Indexed: 11/19/2022] Open
Abstract
This was a prospective study to evaluate the feasibility of the photic phenomena test (PPT) for quantifying glare, halo, and starburst. We compared two presbyopia-correcting intraocular lenses (IOLs), the Symfony IOL and the PanOptix IOL, as well as the monofocal Clareon IOL in 111 IOL-implanted eyes of 111 patients who underwent the PPT 1 month postoperatively. The reproducibility of photic phenomena with the PPT was assessed in 39 multifocal IOL-implanted eyes of 20 patients and among the examiners. Patients with ocular diseases, except for refractive errors, were excluded. The mean values of the groups were evaluated. Bland–Altman plots were used to analyze statistical data (Easy R version 1.37; R Foundation for Statistical Computing, Vienna, Austria). The PPT reproducibility assessment revealed no fixed bias or regressive significance. Reproducibility was confirmed. The glare size did not differ significantly between the Symfony, PanOptix, and Clareon groups. The halo size was significantly larger in the Symfony group (p < 0.01) than in the PanOptix group. The halo intensity was significantly brighter in the PanOptix group (p < 0.01) than in the Symfony group. In contrast, no halos were perceived in the Clareon group. The starburst size or intensity did not differ significantly between the Symfony, PanOptix, and Clareon groups. We identified the photic phenomenon related to various IOLs.
Collapse
|
11
|
Takabatake R, Takahashi M, Yoshimoto T, Higashijima F, Kobayashi Y, Yamashiro C, Kimura K. Cases of replacing diffractive bifocal intraocular lens with extended depth of focus intraocular lens due to waxy vision. PLoS One 2021; 16:e0259470. [PMID: 34714884 PMCID: PMC8555820 DOI: 10.1371/journal.pone.0259470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Accepted: 10/19/2021] [Indexed: 11/18/2022] Open
Abstract
Purpose To investigate the postoperative course of patients who explanted a diffractive bifocal intraocular lens (IOL) due to waxy vision and implanted with an extended depth of focus IOL. Methods This study evaluated 29 eyes of 25 patients who underwent diffractive bifocal IOL explantation followed by TECNIS Symfony® implantation because of dissatisfaction due to waxy vision at the Takabatake West Eye Clinic between January 2018 and November 2019. The indication criteria for this surgery were patients with uncorrected distance visual acuity of 0.05 logMAR or better, without eye diseases that may affect visual function, and no dissatisfactions about photic phenomena. We investigated patient demographics, uncorrected and corrected visual acuity, manifest refraction, contrast sensitivity, subjective symptoms, time to IOL explantation, explanted IOL type, and spectacle independence. Results The time to the IOL exchange after the initial IOL implantation was 55.3 ± 50.4 days (range: 14–196 days). The logMAR corrected distance visual acuity before and after IOL exchange were −0.13 ± 0.06 and −0.14 ± 0.06, respectively (p = 0.273). After IOL exchange surgery, the area under log contrast sensitivity function increased significantly from 1.07 ± 0.12 to 1.21 ± 0.12 (p < 0.001), and the waxy vision symptoms improved. The spectacle independence rate at the last visit was 88.0%. Conclusion For patients who complain of waxy vision despite good visual acuity after diffractive bifocal IOL implantation, exchange to extended depth of focus IOL was considered one of the useful surgical options.
Collapse
Affiliation(s)
- Ryu Takabatake
- Takabatake West Eye Clinic, Okayama City, Okayama, Japan
| | - Makiko Takahashi
- Takabatake West Eye Clinic, Okayama City, Okayama, Japan
- * E-mail:
| | - Takuya Yoshimoto
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Fumiaki Higashijima
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Yuka Kobayashi
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Chiemi Yamashiro
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Kazuhiro Kimura
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| |
Collapse
|
12
|
Gundersen KG, Potvin R. The Effect of Spectacle-Induced Low Myopia in the Non-Dominant Eye on the Binocular Defocus Curve with a Non-Diffractive Extended Vision Intraocular Lens. Clin Ophthalmol 2021; 15:3541-3547. [PMID: 34465974 PMCID: PMC8403224 DOI: 10.2147/opth.s329922] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 08/16/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose To quantify the changes in the binocular defocus curve associated with the Vivity™ non-diffractive extended vision intraocular lens when the dominant eye was targeted for emmetropia and the non-dominant eye was artificially targeted for slight myopia using spectacles. Patients and Methods This was a non-interventional research study of the corrected binocular defocus curve associated with binocular emmetropia (Setting A) and with emmetropia in the dominant eye and two different levels of myopia simulated in the non-dominant eye (−0.50 D, Setting B and −1.00 D, Setting C). Subjects were patients implanted with the AcrySof® IQ Vivity® intraocular lens in both eyes 3 to 12 months previously. Using the defocus data, the percentage of subjects with a continuous 2.5 D range of vision (distance to 40 cm) was calculated for various levels of minimum visual acuity (VA). Results Forty subjects were enrolled. The mean spherical equivalent refraction was −0.06 D ± 0.36 D, with 0.37 D ± 0.29 D of refractive cylinder. There was no statistically significant difference in the mean VA at −0.25 D or at −0.50 D vergences between the test Settings, but there was a statistically significant difference at all other vergences. Differences were particularly noticeable at −2.00 D, −2.50 D and −3.00 D, where higher myopia in the non-dominant eye yielded better binocular VA. A 2.5 D range of functional vision (20/25) was achieved by 38% of subjects at Setting A, 68% of subjects at Setting B and 85% of subjects at Setting C. At setting C, all but one subject (39/40, 97.5%) had a 2.5 D range of vision with a VA of 20/32 or better. Conclusion Significant gains in binocular near vision, with only a nominal effect on distance vision, can be achieved with the Vivity IOL by leaving the non-dominant eye of patients with 0.50 D or 1.00 D of myopia.
Collapse
|
13
|
Visual performance and patient satisfaction after implantation of extended range-of-vision IOLs: bilateral implantation vs 2 different mix-and-match approaches. J Cataract Refract Surg 2021; 47:192-197. [PMID: 32947388 DOI: 10.1097/j.jcrs.0000000000000424] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 08/23/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the visual outcomes and patient satisfaction after bilateral implantation of an extended range-of-vision intraocular lens (ERoV IOL) (Tecnis Symfony) vs 2 different mix-and-match approaches combining the ERoV IOL with bifocal IOLs. SETTING Glory Seoul Eye Clinic, Seoul, South Korea. DESIGN Prospective observational nonrandomized comparative study. METHODS Patients undergoing cataract surgery were distributed into 3 groups based on their lifestyle and near visual demands: bilateral Symfony IOL, mix-and-match Symfony IOL with bifocal +3.25 diopters (D) IOL, and Symfony IOL with bifocal +4.0 D IOL. Binocular uncorrected visual acuity for distance, intermediate, and near, manifest refraction, defocus curve, contrast sensitivity, and subjective visual perception and satisfaction (photic phenomena, spectacle independence, and patient satisfaction) were evaluated at 1 week, 1 month, and 3 months postoperatively. RESULTS The study comprised 103 people (206 eyes). There were no significant differences for uncorrected visual acuity between groups for distance, intermediate, and near vision (P > .05). Contrast sensitivity under low and high luminance conditions was not different between groups (P > .05). Influence of glare on image perception was found to reduce contrast sensitivity more in the bilateral group for smaller target sizes (P < .05). Patients implanted bilaterally with Symfony IOLs reported photic phenomena more frequently than those implanted with the mix-and-match combinations. CONCLUSIONS All combinations evaluated provided good visual outcomes for distance, intermediate, and near. The lower incidence of photic phenomena reported by patients, and the lower reduction on contrast sensitivity for low illumination levels with the presence of glare, suggest that mix-and-match approaches might be a better option compared with bilateral implantation of ERoV IOLs.
Collapse
|
14
|
Schallhorn SC, Schallhorn CS, Teenan D, Venter JA, Hannan SJ, Schallhorn JM. One-Year Outcomes in a Large Series of Patients Following Implantation of an Extended Depth of Focus Intraocular Lens. J Refract Surg 2021; 37:380-388. [PMID: 34170773 DOI: 10.3928/1081597x-20210315-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate clinical outcomes 1 year after implantation of an extended depth of focus intraocular lens (IOL) in a large series of patients. METHODS Outcomes of patients who underwent refractive lens exchange or cataract surgery with the implantation of the AT LARA 829MP IOL (Carl Zeiss Meditec AG) were retrospectively reviewed. The near (40 cm), intermediate (66 cm), and distance visual acuity, refractive outcomes, and cumulative rate of adverse events and secondary procedures were evaluated at 12 months postoperatively. RESULTS A total of 1,894 eyes of 977 patients were implanted with the AT LARA 829MP IOL, with 62.1% of eyes available for the 12-month visit. The overall secondary procedure rate for the whole cohort was: Nd:YAG = 7.8%, laser vision correction = 7.5%, and IOL explantation = 0.63%. The reasons for IOL exchange were intraoperative complications (3 eyes/0.16%) and quality of vision issues (9 eyes/0.48%). Of all eyes available for the 12-month visit that did not undergo laser vision correction or an IOL exchange, 72.0% had monocular uncorrected distance visual acuity of 20/20 or better and the percentage of eyes with monocular uncorrected intermediate and near visual acuity of 20/50 or better was 96.2% and 81.0%, respectively. At 12 months postoperatively, 87.6% of eyes were within ±0.50 diopters of emmetropia. No change in refraction occurred between the 6- and 12-month postoperative visits. CONCLUSIONS The AT LARA 829MP extended depth of focus IOL is able to provide functional distance, intermediate, and near visual acuity. Complications related to the platform of the IOL were uncommon. [J Refract Surg. 2021;37(6):380-388.].
Collapse
|
15
|
Jackson MA, Edmiston AM, Bedi R. Optimum Refractive Target in Patients with Bilateral Implantation of Extended Depth of Focus Intraocular Lenses. Clin Ophthalmol 2020; 14:455-462. [PMID: 32109981 PMCID: PMC7035885 DOI: 10.2147/opth.s237457] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Accepted: 01/22/2020] [Indexed: 01/19/2023] Open
Abstract
Purpose To determine the refractive target of extended depth of focus (EDOF) intraocular lenses in dominant and non-dominant eyes which provides the best binocular vision at all ranges after cataract surgery. Patients and Methods This retrospective, single-center, non-comparative study included 47 patients who had undergone bilateral cataract surgery with implantation of EDOF IOLs (Tecnis Symfony or Tecnis Symfony Toric) targeting emmetropia in both eyes. Binocular uncorrected visual acuity at distance (UDVA), near (UNVA), intermediate (UIVA), and manifest refraction spherical equivalent (MRSE) were recorded between 1 and 3 months after the second-eye cataract surgery. Scattergrams for combined binocular UDVA, UIVA, UNVA and postoperative MRSE were plotted and the points of minima of the quadratic regression curve for the dominant and non-dominant eyes were considered as the optimum MRSE corresponding to the best overall visual acuity. Subgroup analysis of patients who achieved UDVA and UIVA ≥20/20 and UNVA ≥20/30 was also performed. Results For the overall group, the optimum MRSE was −0.08 D for dominant and −0.63 D for non-dominant eyes. In a subset of 17 patients who achieved excellent acuity at all distances, the mean MRSE for the dominant and non-dominant eyes was −0.07 ± 0.14 D and −0.21 ± 0.24 D, respectively. Conclusion Excellent visual acuity at all ranges can be achieved with bilateral EDOF intraocular lenses implanted after cataract surgery. Our results indicate the best results when the dominant eye is targeted at emmetropia and the nondominant eye is targeted between −0.21D and −0.63D, with excellent results shown with mild myopia of −0.21 in the non-dominant eyes. Future studies with larger sample sizes and subjective patient-reported outcomes may validate current study outcomes.
Collapse
|