An outbreak of Legionnaires' disease linked to a municipal and industrial wastewater treatment plant, The Netherlands, September-October 2022. Euro Surveill 2024; 29:2300506. [PMID: 38757288 PMCID: PMC11100293 DOI: 10.2807/1560-7917.es.2024.29.20.2300506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 02/19/2024] [Indexed: 05/18/2024] Open
Abstract
Wastewater treatment plants (WWTPs) are increasingly identified as Legionnaires' disease (LD) sources. An outbreak investigation was initiated following five LD cases reported in September 2022 in Houten, the Netherlands. Case identification was based on the European LD case definition, with symptom onset from 1 September 2022, residence in or within 5 km of Houten, or visit to Houten within the incubation period, without other likely sources. We sampled potential sources and genotyped environmental and clinical isolates. We identified 15 LD cases with onset between 13 September and 23 October 2022. A spatial source identification and wind direction model suggested an industrial (iWWTP) and a municipal WWTP (mWWTP) as potential sources, with the first discharging water into the latter. Both tested positive for Legionella pneumophila serogroups 1 and 6 with multiple sequence types (ST). We detected L. pneumophila sg1 ST42 in the mWWTP, matching with one of three available clinical isolates. Following control measures at the WWTPs, no further cases were observed. This outbreak underlines that municipal and industrial WWTPs can play an important role in community LD cases and outbreaks, especially those with favourable conditions for Legionella growth and dissemination, or even non-favourable conditions for growth but with the influx of contaminated water.
Collapse
|
2
|
Prevalence of opportunistic pathogens in a school building plumbing during periods of low water use and a transition to normal use. Int J Hyg Environ Health 2022; 241:113945. [PMID: 35182850 DOI: 10.1016/j.ijheh.2022.113945] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 01/28/2022] [Accepted: 02/10/2022] [Indexed: 11/23/2022]
Abstract
The spread of opportunistic pathogens via building water supply and plumbing is of public health concern. This study was conducted to better understand microbial water quality changes in a LEED-certified school building during low water use (Summer) and normal water use (Autumn). The copper plumbed building contained water saving devices, a hot water recirculation system, and received chloraminated drinking water from a public water system. Three separate sampling events were conducted during the summer break inside the building and another three sampling events were conducted after the school returned to session. Using quantitative PCR, Legionella spp. were detected in all water samples, followed by Mycobacterium spp. (99%). Mycobacterium avium (75%) and Acanthamoeba spp. (17.5%) throughout the building water system. Legionella pneumophila and Naegleria fowleri were not detected in any of the samples. The mean concentrations of Legionella spp., Mycobacterium spp., Mycobacterium avium, and Acanthamoeba spp. detected in water samples were 3.9, 5.7, 4.7, and 2.8 log10 gene copies per 100 ml, respectively. There was a statistically significantly difference in the mean concentrations of Legionella spp., Mycobacterium spp. and M. avium gene markers in water samples between school breaks and when school was in session. Cultivable Legionella were also detected in water samples collected during periods of low water use. This study highlights the need for routine proactive water quality testing in school buildings to determine the extent of drinking water quality problems associated with plumbing and direct action to remediate microbial colonization.
Collapse
|
3
|
Membrane bioreactors for hospital wastewater treatment: recent advancements in membranes and processes. Front Chem Sci Eng 2021; 16:634-660. [PMID: 34849268 PMCID: PMC8617552 DOI: 10.1007/s11705-021-2107-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 08/15/2021] [Indexed: 11/26/2022]
Abstract
Discharged hospital wastewater contains various pathogenic microorganisms, antibiotic groups, toxic organic compounds, radioactive elements, and ionic pollutants. These contaminants harm the environment and human health causing the spread of disease. Thus, effective treatment of hospital wastewater is an urgent task for sustainable development. Membranes, with controllable porous and nonporous structures, have been rapidly developed for molecular separations. In particular, membrane bioreactor (MBR) technology demonstrated high removal efficiency toward organic compounds and low waste sludge production. To further enhance the separation efficiency and achieve material recovery from hospital waste streams, novel concepts of MBRs and their applications are rapidly evolved through hybridizing novel membranes (non hydrophilic ultrafiltration/microfiltration) into the MBR units (hybrid MBRs) or the MBR as a pretreatment step and integrating other membrane processes as subsequent secondary purification step (integrated MBR-membrane systems). However, there is a lack of reviews on the latest advancement in MBR technologies for hospital wastewater treatment, and analysis on its major challenges and future trends. This review started with an overview of main pollutants in common hospital waste-water, followed by an understanding on the key performance indicators/criteria in MBR membranes (i.e., solute selectivity) and processes (e.g., fouling). Then, an in-depth analysis was provided into the recent development of hybrid MBR and integrated MBR-membrane system concepts, and applications correlated with wastewater sources, with a particular focus on hospital wastewaters. It is anticipated that this review will shed light on the knowledge gaps in the field, highlighting the potential contribution of hybrid MBRs and integrated MBR-membrane systems toward global epidemic prevention.
Collapse
|
4
|
The wastewater protist Rhogostoma minus (Thecofilosea, Rhizaria) is abundant, widespread, and hosts Legionellales. WATER RESEARCH 2021; 203:117566. [PMID: 34438261 DOI: 10.1016/j.watres.2021.117566] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Revised: 07/19/2021] [Accepted: 08/11/2021] [Indexed: 06/13/2023]
Abstract
Wastewater is treated by concerted actions of the microbial communities within bioreactors. Although protists (unicellular eukaryotes) are good bioindicators and important players influencing denitrification, nitrification, and flocculation, they are the least known organisms in WWTPs. The few recent environmental surveys of the protistan diversity in WWTPs show that the most abundant protistan sequences in WWTPs belong to Thecofilosea (Rhizaria). We re-investigated previously published environmental sequencing data and gathered strains from seven WWTPs to determine which species dominate WWTPs worldwide. We found that all highly abundant thecofilosean sequences represent a single species - Rhogostoma minus. Considering that Thecofilosea are frequent hosts for Legionellales, i.e. bacteria linked to waterborne diseases, we confirm that Rhogostoma minus functions as a host for Legionellales in WWTPs. Whether the highly abundant Rhogostoma minus also serves as a host for known human pathogenic Legionellales requires further attention.
Collapse
|
5
|
Are pathogenic Legionella non-pneumophila a common bacteria in Water Distribution Networks? WATER RESEARCH 2021; 196:117013. [PMID: 33813251 DOI: 10.1016/j.watres.2021.117013] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 02/16/2021] [Accepted: 03/04/2021] [Indexed: 05/22/2023]
Abstract
The present study analyzes at the national level, the presence of circulating Legionella in the artificial aquatic systems of different facilities of all of them state-owned centers throughout Spain for 12 months. 1754 water samples from various state-owned centers were collected from January to December 2014. Samples were collected from the cooling towers and evaporative condensers (CTC), and water distribution networks such as domestic hot water (DHW), cold water for human consumption (CW), sprinkler irrigation systems (SIS), fire sprinkler systems (FSS), and water from decorative fountains (DF). All these facilities are considered, according to current regulations, as potential amplifying systems for bacteria and possible sources of infection by the generation of droplets and aerosols. The isolation and counting of Legionella in water samples was carried out using microbiological culture following the international normative UNE-EN-ISO 11,731:2007 (ISO 11,731:1998) and UNE-EN ISO 8199:2008 (ISO 8199:2005).The quantification of Legionella colonization, the annual distribution, and the geographical distribution of the Legionella isolates recovered in the water were analyzed. Besides, molecular techniques were used for the characterization of the Legionella non-pneumophila isolates. Legionella was recovered from 15.79% of the analyzed water samples. High colonization was more frequently detected in water samples from CTC, DHW, CW, and DF. Regarding the geographic distribution, positive samples of Legionella were obtained in 14 of the 18 Spanish locations analyzed. Legionella non-pneumophila was the most prevalent and was isolated from water samples from 13 different geographical locations (72%). Legionella anisa and Legionella jordanis were the most frequently non-pneumophila species isolated. Legionella donaldsonii was isolated for the first time in the water distribution networks in Spain. Legionella pneumophila sg 2-14 was detected in 13 locations and Legionella pneumophila sg 1 in 11 locations. Therefore, our study concludes that the presence of Legionella pneumophila and Legionella non-pneumophila species in these systems can be a potential threat to public health and should be examined thoroughly with complementary techniques, such as molecular techniques as a screen for routine diagnosis.
Collapse
|
6
|
Abstract
Biological high-risk pollutants (HRPs) have become a serious threat to human health worldwide, and wastewater is one of the major sources of them in a natural environment. Despite the long history of wastewater research, comprehensive understanding of the role and behavior of HRPs during wastewater treatment is still limited owing to the complexity of the community. In recent decades, the rapid development of molecular tools, especially the wide application of next generation sequencing technologies, helps to unravel the community composition, structure, and dynamic variation in wastewater. Overall, this chapter mainly focuses on biological HRPs, including bacteria, viruses, protozoa, helminth, biotoxins, antibiotic resistance genes and antibiotic resistant bacteria in wastewater. The characteristics, classification, fates, functions, and health implications of these HRPs are introduced in detail. Moreover, the biogeography of HRPs is a research hotspot in recent years, and available information is also summarized in this chapter. Finally, we also propose the future research needs of HRPs in wastewater after the comprehensive summary of the existing research reports. This chapter is wished to be helpful for beginners to quickly understand the biological HRPs in wastewater.
Collapse
|
7
|
Legionella occurrence in municipal and industrial wastewater treatment plants and risks of reclaimed wastewater reuse: Review. WATER RESEARCH 2019; 149:21-34. [PMID: 30445393 DOI: 10.1016/j.watres.2018.10.080] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 10/26/2018] [Accepted: 10/27/2018] [Indexed: 05/22/2023]
Abstract
Wastewater treatment plants (WWTPs) have been identified as confirmed but until today underestimated sources of Legionella, playing an important role in local and community cases and outbreaks of Legionnaires' disease. In general, aerobic biological systems provide an optimum environment for the growth of Legionella due to high organic nitrogen and oxygen concentrations, ideal temperatures and the presence of protozoa. However, few studies have investigated the occurrence of Legionella in WWTPs, and many questions in regards to the interacting factors that promote the proliferation and persistence of Legionella in these treatment systems are still unanswered. This critical review summarizes the current knowledge about Legionella in municipal and industrial WWTPs, the conditions that might support their growth, as well as control strategies that have been applied. Furthermore, an overview of current quantification methods, guidelines and health risks associated with Legionella in reclaimed wastewater is also discussed in depth. A better understanding of the conditions promoting the occurrence of Legionella in WWTPs will contribute to the development of improved wastewater treatment technologies and/or innovative mitigation approaches to minimize future Legionella outbreaks.
Collapse
|
8
|
Analysis of population-level determinants of legionellosis: spatial and geovisual methods for enhancing classification of high-risk areas. Int J Health Geogr 2017; 16:45. [PMID: 29197383 PMCID: PMC5712152 DOI: 10.1186/s12942-017-0118-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Accepted: 11/25/2017] [Indexed: 01/17/2023] Open
Abstract
Background Although the incidence of legionellosis throughout North America and Europe continues to increase, public health investigations have not been able to identify a common exposure in most cases. Over 80% of cases are sporadic with no known source. To better understand the role of the macro-environment in legionellosis risk, a retrospective ecological study assessed associations between population-level measures of demographic, socioeconomic, and environmental factors and high-risk areas. Methods Geographic variability and clustering of legionellosis was explored in our study setting using the following methods: unadjusted and standardized incidence rate and SaTScan™ cluster detection methods using default scanning window of 1 and 50% as well as a reliability score methodology. Methods for classification of “high-risk” census tracts (areas roughly equivalent to a neighborhood with average population of 4000) for each of the spatial methods are presented. Univariate and multivariate logistic regression analyses were used to estimate associations with sociodemographic factors: population ≥ 65 years of age, non-white race, Hispanic ethnicity, poverty, less than or some high school education; housing factors: housing vacant, renter-occupied, and built pre-1950 and pre-1970; and whether drinking water is groundwater or surface water source. Results Census tracts with high percentages of poverty, Hispanic population, and non-white population were more likely to be classified as high-risk for legionellosis versus a low-risk census tract. Vacant housing, renter-occupied housing, and homes built pre-1970 were also important positively associated risk factors. Drinking water source was not found to be associated with legionellosis incidence. Discussion Census tract level demographic, socioeconomic, and environmental characteristics are important risk factors of legionellosis and add to our understanding of the macro-environment for legionellosis occurrence. Our findings can be used by public health professionals to target disease prevention communication to vulnerable populations. Future studies are needed to explore the exact mechanisms by which these risk factors may influence legionellosis clustering.
Collapse
|
9
|
Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment. BUILDING AND ENVIRONMENT 2017; 123:684-695. [PMID: 29104349 PMCID: PMC5665586 DOI: 10.1016/j.buildenv.2017.06.024] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Legionella is a genus of pathogenic Gram-negative bacteria responsible for a serious disease known as legionellosis, which is transmitted via inhalation of this pathogen in aerosol form. There are two forms of legionellosis: Legionnaires' disease, which causes pneumonia-like symptoms, and Pontiac fever, which causes influenza-like symptoms. Legionella can be aerosolized from various water sources in the built environment including showers, faucets, hot tubs/swimming pools, cooling towers, and fountains. Incidence of the disease is higher in the summertime, possibly because of increased use of cooling towers for air conditioning systems and differences in water chemistry when outdoor temperatures are higher. Although there have been decades of research related to Legionella transmission, many knowledge gaps remain. While conventional wisdom suggests that showering is an important source of exposure in buildings, existing measurements do not provide strong support for this idea. There has been limited research on the potential for Legionella transmission through heating, ventilation, and air conditioning (HVAC) systems. Epidemiological data suggest a large proportion of legionellosis cases go unreported, as most people who are infected do not seek medical attention. Additionally, controlled laboratory studies examining water-to-air transfer and source tracking are still needed. Herein, we discuss ten questions that spotlight current knowledge about Legionella transmission in the built environment, engineering controls that might prevent future disease outbreaks, and future research that is needed to advance understanding of transmission and control of legionellosis.
Collapse
|
10
|
Occurrence of Legionella in wastewater treatment plants linked to wastewater characteristics. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:16873-16881. [PMID: 27376367 DOI: 10.1007/s11356-016-7090-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2016] [Accepted: 06/13/2016] [Indexed: 06/06/2023]
Abstract
In recent years, the occurrence of Legionella in wastewater treatment plants (WWTP) has often been reported. However, until now there is limited knowledge about the factors that promote Legionella's growth in such systems. The aim of this study was to investigate the chemical wastewater parameters that might be correlated to the concentration of Legionella spp. in WWTP receiving industrial effluents. For this purpose, samples were collected at different processes in three WWTP. In 100 % of the samples taken from the activated sludge tanks Legionella spp. were detected at varying concentrations (4.8 to 5.6 log GU/mL) by the quantitative real-time polymerase chain reaction method, but not by the culture method. Statistical analysis with various parameters yielded positive correlations of Legionella spp. concentration with particulate chemical oxygen demand, Kjeldahl nitrogen and protein concentration. Amino acids were quantified in wastewater and activated sludge samples at concentrations that may not support the growth of Legionella, suggesting that in activated sludge tanks this bacterium multiplied in protozoan hosts.
Collapse
|
11
|
First Case of Legionnaire's Disease Caused by Legionella anisa in Spain and the Limitations on the Diagnosis of Legionella non-pneumophila Infections. PLoS One 2016; 11:e0159726. [PMID: 27442238 PMCID: PMC4956277 DOI: 10.1371/journal.pone.0159726] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Accepted: 05/27/2016] [Indexed: 12/13/2022] Open
Abstract
Legionnaires' disease is a severe form of pneumonia, with worldwide relevance, caused by Legionella spp. Approximately 90% of all cases of legionellosis are caused by Legionella pneumophila, but other species can also be responsible for this infection. These bacteria are transmitted by inhalation of aerosols or aspiration of contaminated water. In Spain, environmental studies have demonstrated the presence of Legionella non-pneumophila species in drinking water treatment plants and water distribution networks. Aware that this evidence indicates a risk factor and the lack of routine assays designed to detect simultaneously diverse Legionella species, we analyzed 210 urine samples from patients presenting clinical manifestations of pneumonia using a semi-nested PCR for partial amplification of the 16S rDNA gene of Legionella and a diagnostic method used in hospitals for Legionella antigen detection. In this study, we detected a total of 15 cases of legionellosis (7.1%) and the first case of Legionnaires' disease caused by L. anisa in Spain. While the conventional method used in hospitals could only detect four cases (1.9%) produced by L. pneumophila serogroup 1, using PCR, the following species were identified: Legionella spp. (10/15), L. pneumophila (4/15) and L. anisa (1/15). These results suggest the need to change hospital diagnostic strategies regarding the identification of Legionella species associated with this disease. Therefore, the detection of Legionella DNA by PCR in urine samples seems to be a suitable alternative method for a sensitive, accurate and rapid diagnosis of Legionella pneumonia, caused by L. pneumophila and also for L. non-pneumophila species.
Collapse
|
12
|
Microbiological and Clinical Studies of Legionellosis in 33 Patients with Cancer. J Clin Microbiol 2015; 53:2180-7. [PMID: 25926494 PMCID: PMC4473214 DOI: 10.1128/jcm.00380-15] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Accepted: 04/21/2015] [Indexed: 11/20/2022] Open
Abstract
Legionella, a large group of environmental Gram-negative bacteria, represents an occasional cause of pneumonia. We analyzed the microbiological and clinical features of 33 consecutive cases of Legionella infections that occurred at the University of Texas MD Anderson Cancer Center, Houston, TX, from 2002 to 2014. The Legionella strains were isolated from bronchoscopy specimens (32 strains) and a blood culture (1 strain) and were identified by sequencing analysis of the full-length 16S rRNA gene. The 33 strains involved 12 Legionella species or subspecies: 15 strains of L. pneumophila subsp. pneumophila, 3 strains of L. pneumophila subsp. fraseri or L. pneumophila subsp. pascullei, 4 strains of "L. donaldsonii," 3 strains of L. micdadei, and one each of L. bozemanae, L. feeleii, L. gormanii, L. longbeachae, L. maceachernii, L. parisiensis, L. sainthelensi, and Legionella sp. strain D5382. All patients except one asymptomatic carrier showed pneumonia, including one with concurrent bacteremia. Nine patients died, with this infection being the immediate cause of death in six. Twenty-seven patients had underlying hematologic malignancies. Twenty-three patients were leukopenic. Six patients were recipients of allogeneic hematopoietic stem cell transplant, with their infections caused by five Legionella species. Together, these results suggest that diverse Legionella species infect patients with cancer in the Houston area and its vicinity. The five cases of pneumonia due to L. donaldsonii and Legionella sp. D5382 are likely the first reports of human infection with these organisms.
Collapse
|
13
|
Abstract
Legionella bacteria are ubiquitous in natural matrices and man-made systems. However, it is not always clear if these reservoirs can act as source of infection resulting in cases of Legionnaires' disease. This review provides an overview of reservoirs of Legionella reported in the literature, other than drinking water distribution systems. Levels of evidence were developed to discriminate between potential and confirmed sources of Legionella. A total of 17 systems and matrices could be classified as confirmed sources of Legionella. Many other man-made systems or natural matrices were not classified as a confirmed source, since either no patients were linked to these reservoirs or the supporting evidence was weak. However, these systems or matrices could play an important role in the transmission of infectious Legionella bacteria; they might not yet be considered in source investigations, resulting in an underestimation of their importance. To optimize source investigations it is important to have knowledge about all the (potential) sources of Legionella. Further research is needed to unravel what the contribution is of each confirmed source, and possibly also potential sources, to the LD disease burden.
Collapse
|
14
|
Detection of Legionella spp. by a nested-PCR assay in air samples of a wastewater treatment plant and downwind distances in Isfahan. Adv Biomed Res 2015; 4:48. [PMID: 25802817 PMCID: PMC4361962 DOI: 10.4103/2277-9175.151540] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Accepted: 05/31/2014] [Indexed: 11/28/2022] Open
Abstract
Background: Wastewater contains a variety of pathogens and bio -aerosols generated during the wastewater treatment process, which could be a potential health risk for exposed individuals. This study was carried out to detect Legionella spp. in the bio -aerosols generated from different processes of a wastewater treatment plant (WWTP) in Isfahan, Iran, and the downwind distances. Materials and Methods: A total of 54 air samples were collected and analyzed for the presence of Legionella spp. by a nested- polymerase chain reaction (PCR) assay. A liquid impingement biosampler was used to capture bio -aerosols. The weather conditions were also recorded. Results: Legionella were detected in 6% of the samples, including air samples above the aeration tank (1/9), belt filter press (1/9), and 250 m downwind (1/9). Conclusion: The result of this study revealed the presence of Legionella spp. in air samples of a WWTP and downwind distance, which consequently represent a potential health risk to the exposed individuals.
Collapse
|
15
|
Identification and quantitative detection of Legionella spp. in various aquatic environments by real-time PCR assay. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2013; 20:6128-6137. [PMID: 23536272 DOI: 10.1007/s11356-013-1534-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2012] [Accepted: 01/29/2013] [Indexed: 06/02/2023]
Abstract
In this study, a SYBR green quantitative real-time PCR was developed to quantify and detect the Legionella spp. in various environmental water samples. The water samples were taken from watershed, water treatment plant, and thermal spring area in Taiwan. Legionella was detected in 13.6 % (24/176), and the detection rate for river water, raw drinking water, and thermal spring water was 10, 21.4, and 16.6 %, respectively. Using real-time PCR, concentration of Legionella spp. in detected samples ranged between 9.75 × 10(4) and 3.47 × 10(5) cells/L in river water, 6.92 × 10(4) and 4.29 × 10(5) cells/L in raw drinking water, and 5.71 × 10(4) and 2.12 × 10(6) cells/L for thermal spring water samples. The identified species included Legionella pneumophila (20.8 %), Legionella jordanis (4.2 %), Legionella nautarum (4.2 %), Legionella sp. (4.2 %), and uncultured Legionella sp. (66.6 %). The presence of L. pneumophila in aquatic environments suggested a potential public health threat that must be further examined.
Collapse
|
16
|
Abstract
Legionella pneumophila were previously identified in the aeration ponds (up to 1010CFU/L) of a biological wastewater treatment plant at Borregaard Ind. Ltd., Sarpsborg, Norway, and in air samples (up to 3300 CFU/m3) collected above the aeration ponds. After 3 outbreaks of Legionnaires’ disease reported in this area in 2005 and 2008, the aeration ponds of the plant were shut down by the Norwegian authorities in September 2008. The aim of the present work was to analyze the Legionella and non-Legionella bacterial communities in the aeration ponds before and during the shutdown process and to identify potential human pathogens. The non-Legionella bacterial community was investigated in selected samples during the shutdown process by 16S rDNA sequencing of clone libraries (400 clones) and growth analysis. The concentration of L. pneumophila and Pseudomonas spp. DNA were monitored by quantitative PCR. Results showed a decrease in the concentration of L. pneumophila and Pseudomonas spp. during the shutdown. This was accompanied by a significant change in the composition of the bacterial community in the aeration ponds. This study demonstrated that several advanced analytical methods are necessary to characterize the bacterial population in complex environments, such as the industrial aeration ponds.
Collapse
|