1
|
Shen V, Andrews R, Binitie O, Palumbo BT. Possible Transformation of Pseudotumor to Synovial Sarcoma in a Failed Metal-on-Metal Total Hip Arthroplasty. Arthroplast Today 2024; 29:101408. [PMID: 39391234 PMCID: PMC11466573 DOI: 10.1016/j.artd.2024.101408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 04/19/2024] [Accepted: 04/27/2024] [Indexed: 10/12/2024] Open
Abstract
Adverse local tissue reaction (ALTR) from the release of chromium and cobalt ions in metal-on-metal total hip arthroplasty (MoM THA) is a well-reported complication, but there is little evidence suggesting that this inflammatory reaction causes malignancy. We present a 69-year-old female with MoM THA who developed synovial sarcoma (SS). She underwent mass resection and revision THA. Postoperative pathologic analysis revealed the unanticipated diagnosis of SS. She subsequently underwent chemotherapy, sarcoma resection, and endoprosthetic reconstruction. We hypothesize that the SS developed from an ALTR in the setting of failed MoM THA. Given the paucity of data on possible malignant transformation of an ALTR to SS, we advise surgeons to consider potential malignancies when diagnosing ALTR in the setting of failed MoM THA bearings.
Collapse
Affiliation(s)
- Victor Shen
- Department of Orthopaedic Surgery, University of Southern Florida Health Morsani College of Medicine, Tampa, FL, USA
| | - Reed Andrews
- Department of Orthopaedic Surgery, University of Southern Florida Health Morsani College of Medicine, Tampa, FL, USA
- Department of Orthopaedic Surgery, Florida Orthopaedic Institute, Tampa, FL, USA
| | - Odion Binitie
- Department of Orthopaedic Surgery, University of Southern Florida Health Morsani College of Medicine, Tampa, FL, USA
- Department of Orthopaedic Surgery, Moffitt Cancer Center, Tampa, FL, USA
| | - Brian T. Palumbo
- Department of Orthopaedic Surgery, University of Southern Florida Health Morsani College of Medicine, Tampa, FL, USA
- Department of Orthopaedic Surgery, Florida Orthopaedic Institute, Tampa, FL, USA
| |
Collapse
|
2
|
Samuel LT, Rabin JM, Arnold NR, Munim M, Brooks PJ, Mont MA. Metal-on-metal (MoM) hip implants and pregnancy: are MoM implants good for mom?-a systematic review. ANNALS OF TRANSLATIONAL MEDICINE 2023; 11:363. [PMID: 37675314 PMCID: PMC10477648 DOI: 10.21037/atm.2019.07.44] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Accepted: 07/15/2019] [Indexed: 09/08/2023]
Abstract
Metal-on-metal (MoM) bearing surfaces were historically used for young patients undergoing total hip arthroplasty (THA), and remain commonplace in modern hip resurfacing. A substantial number of female patients with MoM bearings subsequently gave birth following implantation of the bearings before a full understanding of metal ions exposure in these patients was established. In theory, it has been postulated that metal ions released from such implants may cross the placental barrier and cause harm to the fetus. In light of this potential risk, recommendations against the use of MoM components in women of child-bearing age have been advocated. The purpose of this systematic review was to evaluate: (I) the MoM bearing types and ion levels found; (II) the concentrations of metals in maternal circulation and the umbilical cord; and (III) the presence of abnormalities in the fetus or delivered child. A comprehensive literature review was conducted of studies published between January 1st, 1975 and April 1st, 2019 using specific keywords. We defined the inclusion criteria for qualifying studies for this review as follows: (I) studies that reported on the women who experienced pregnancy and who had a MoM hip implant; (II) studies that reported on maternal metal ions blood and umbilical cord levels; and (III) studies that reported on the occurrence of fetal complications. Data on cobalt and chromium ion levels in the maternal blood and umbilical cord blood, as well as the presence of adverse effects in the infant were collected. Age at parturition and time from MoM implant to parturition were also collected. A total of six studies were included in the final analysis that reported on a total of 21 females and 21 infants born. The mean age at parturition was 31 years (range, 24 to 41 years), and the mean time from MoM implantation to parturition was 47 months (range, 11 to 119 months). Maternal blood cobalt levels were found as a weighted average of 34.09 µg/L (0.425 to 138 µg/L), while umbilical cord blood cobalt levels were found to be 22.61 µg/L (0.52 to 51.11 µg/L). Cobalt levels were reduced by an average of 34% between maternal and umbilical cord blood. Maternal cord blood chromium levels were found as a weighted average of 18.18 µg/L (0.225 to 75 µg/L), while umbilical cord chromium levels were found to be 3.96 µg/L (0.14 to 11.96 µg/L). Chromium levels were reduced by an average of 78% between maternal and umbilical cord blood. No cobalt or chromium was detected in the umbilical cord blood of three patients. Out of the 21 infants born to women with MoM implants, 20 were born healthy with no adverse effects or complications. Only one complication was recorded in single infant that did not appear to be related to the maternal MoM implant. To date, there is a lack of consensus as to whether MoM hip arthroplasty implants are to be avoided in the child-bearing female population and whether they constitute a hazard to the fetus in utero. Both chromium and cobalt ions were markedly reduced in levels when transitioning from maternal to cord blood. In particular, chromium showed a greater reduction on average than cobalt (78% vs. 34%). Based on the current evidence, there appears to be no correlation between the presence of metal ions in umbilical cord blood and complications, as none of the infants experienced abnormalities uniquely attributable to the presence of metal ions.
Collapse
Affiliation(s)
- Linsen T. Samuel
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Jacob M. Rabin
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Nicholas R. Arnold
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Mohammed Munim
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Peter J. Brooks
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Michael A. Mont
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA
- Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA
| |
Collapse
|
3
|
Usman K, Kang D, Jeong G, Alam K, Raveendran A, Ser J, Jang W, Cho H. The Surface Properties of Implant Materials by Deposition of High-Entropy Alloys (HEAs). NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1123. [PMID: 36986017 PMCID: PMC10054136 DOI: 10.3390/nano13061123] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/16/2023] [Accepted: 03/19/2023] [Indexed: 06/18/2023]
Abstract
High-entropy alloys (HEAs) contain more than five alloying elements in a composition range of 5-35% and with slight atomic size variation. Recent narrative studies on HEA thin films and their synthesis through deposition techniques such as sputtering have highlighted the need for determining the corrosion behaviors of such alloys used as biomaterials, for example, in implants. Coatings composed of biocompatible elements such as titanium, cobalt, chrome, nickel, and molybdenum at the nominal composition of Co30Cr20Ni20Mo20Ti10 were synthesized by means of high-vacuum radiofrequency magnetron (HVRF) sputtering. In scanning electron microscopy (SEM) analysis, the coating samples deposited with higher ion densities were thicker than those deposited with lower ion densities (thin films). The X-ray diffraction (XRD) results of the thin films heat treated at higher temperatures, i.e., 600 and 800 °C, revealed a low degree of crystallinity. In thicker coatings and samples without heat treatment, the XRD peaks were amorphous. The samples coated at lower ion densities, i.e., 20 µAcm-2, and not subjected to heat treatment yielded superior results in terms of corrosion and biocompatibility among all the samples. Heat treatment at higher temperatures led to alloy oxidation, thus compromising the corrosion property of the deposited coatings.
Collapse
Affiliation(s)
- Khalid Usman
- School of Materials Science & Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Doori Kang
- School of Materials Science & Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Geonwoo Jeong
- School of Materials Science & Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Khurshed Alam
- School of Materials Science & Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Athira Raveendran
- School of Materials Science & Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Jinhui Ser
- School of Materials Science & Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Woohyung Jang
- Department of Prosthodontics, School of Dentistry, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Hoonsung Cho
- School of Materials Science & Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| |
Collapse
|
4
|
Abdel Hamid OI, Attia ME, Hirshon JM, El-Shinawi M, El-Hussaini M, El-Setouhy M. Psychiatric Disorders and Genotoxicity Following Primary Metal on Polyethylene Total Hip Arthroplasty and Their Correlation to Cobalt/Chromium Levels. Drug Healthc Patient Saf 2022; 14:97-111. [PMID: 35880007 PMCID: PMC9308046 DOI: 10.2147/dhps.s360643] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 07/04/2022] [Indexed: 11/23/2022] Open
Abstract
Introduction Hip arthroplasty (HA) using implantable metal components is among the commonest orthopedic interventions. However, it can be followed by several complications following corrosion and the release of metal ions. Several studies proved that damaged genomic DNA may contribute to the pathophysiology of mental disorders. Aim The current work aims to evaluate the psychiatric disorders in metal on polyethylene hip arthroplasty (MOP-HA) patients and its correlation to cobalt/chromium (Co/Cr) levels and genotoxicity. Methods The work was a longitudinal follow-up study including 34 adults with unilateral primary MOP-HA meeting the inclusion and exclusion criteria. Preoperatively, 6, 12-months-postoperatively, patients were examined for cognitive impairment using mini-mental-state-examination (MMSE), depression using major-depressive-inventory (MDI), and blood samples were collected for estimation of Co/Cr, detection of genotoxicity by single-cell-gel-electrophoresis (comet assay) and serum 8-hydroxy-2'-deoxyguanosine (8-OHdG). Results Cognitive impairment was reported in 18.5% and 14.8% at 6-months, and 12-months postoperative, respectively. Depressive disorder was recorded in 22.2% at 6-months and 14.8% at 12-months postoperative. The marginal homogeneity tests proved a non-significant difference. There was a non-significant difference in preoperative, 6-months, 12-months postoperative MMSE, and MDI scores. There were significantly increased Co/Cr levels at 6-months postoperative. The levels decreased at 12-months postoperative, however, still significantly higher than preoperative values. There was a significant increase in serum 8-OHdG and the levels were positively correlated to cobalt levels at both 6 and 12-months-postoperative. There was a non-significant difference among preoperative, 6-months, and 12-months postoperative comet assay measurements. Conclusion From previous findings, we can conclude that will-functioning MOP hip arthroplasty can induce increased ion levels and positively correlated increase in biochemical markers of genotoxicity (8-OHdG).
Collapse
Affiliation(s)
- Omaima I Abdel Hamid
- Forensic Medicine and Clinical Toxicology Department, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | - Mohamed E Attia
- Orthopedics Departments, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | - Jon M Hirshon
- Department of Emergency Medicine, University of Maryland, School of Medicine, Baltimore, MD, USA
- Department of Epidemiology and Public Health, University of Maryland, School of Medicine, Baltimore, MD, USA
| | - Mohamed El-Shinawi
- Department of General Surgery, Faculty of Medicine, Ain Shams University, Cairo, Egypt
- Galala University, Galala City, Suez, Egypt
| | - Moustafa El-Hussaini
- Department of Community, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Maged El-Setouhy
- Department of Community, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt
- Department of Family and Community Medicine, Faculty of Medince, Jazan University, Jazan, Kingdom of Saudi Arabia
| |
Collapse
|
5
|
Ishida T, Tateiwa T, Takahashi Y, Nishikawa Y, Shishido T, Masaoka T, Yamamoto K. Adverse Tissue Reactions and Metal Ion Behavior After Small-Head Metasul Hip Arthroplasty: A Long-Term Follow-Up Study. Orthop Surg 2021; 14:264-273. [PMID: 34910382 PMCID: PMC8867442 DOI: 10.1111/os.13125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 05/10/2021] [Accepted: 06/03/2021] [Indexed: 11/29/2022] Open
Abstract
Objective To investigate the long‐term survivorship, incidence of adverse reactions to metal debris (ARMD), and metal ion behavior in patients who underwent small‐head Metasul metal‐on‐metal (MoM) total hip arthroplasty (THA). Methods Between February 1998 and September 2003, a retrospective study was performed on 43 consecutive patients (43 hips) who underwent unilateral cementless Metasul MoM THAs at our institution. Of them, 35 patients (nine males and 26 females) who were available for follow‐up more than 15 years after THA were enrolled in this study and underwent metal artifact reduction sequence magnetic resonance imaging (MARS‐MRI) to identify ARMD. The mean age at surgery of the patients was 59.7 years old (range, 31–83). Clinical and radiographic outcomes were evaluated retrospectively. Clinical examinations were conducted using the Harris Hip Score (HHS). Serum cobalt (Co) and chromium (Cr) ion levels and Co/Cr ratio were assessed at different postoperative periods of <5, 5–10, 11–14, and ≥15 years. Results The mean follow‐up period for the 35 patients included was 18.1 years (range, 15–22). The mean HHS significantly improved from 44.6 ± 11.3 points preoperatively to 89.4 ± 7.9 points at the final follow‐up (P < 0.0001). ARMD was found in 20% of the patients using MARS‐MRI. No signs of stem loosening were found clinically or radiographically, whereas cup loosening and ARMD were observed in three patients (9%), for whom revision THAs were performed. The Kaplan–Meier survival rates with revision for any reason as the endpoint were 90.9% at 5 years, 84.8% at 10 years, 84.8% at 15 years (95% CI, 67.1–93.6), and 70.3% at 20 years (95% CI, 43.6–87.0). The survival rates with revision for ARMD as the endpoint were 100% at 5 years, 96.6% at 10 years, 96.6% at 15 years (95% CI, 77.2–99.7), and 80.1% at 20 years (95% CI, 45.3–95.2). Serum Co ion level peaked at 5–10 years after THA, which was significantly higher than that <5 years; however, it decreased to the initial level after 15 years. In contrast, serum Cr ion level significantly increased at 5–10 years and then remained almost constant. Significant differences in Cr ion levels (1.0 vs 2.0 μg/L, P = 0.024) and Co/Cr ratio (1.3 vs 0.9, P = 0.037) were found between non‐ARMD and ARMD patients at >11 years postoperatively. Conclusion Our results suggest that increased Cr ion levels and decreased Co/Cr ratio may be signs of ARMD in patients who underwent small‐head Metasul MoM THA.
Collapse
Affiliation(s)
- Tsunehito Ishida
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Toshiyuki Tateiwa
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Yasuhito Takahashi
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan.,Department of Bone and Joint Biomaterial Research, Tokyo Medical University, Tokyo, Japan
| | - Yohei Nishikawa
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Takaaki Shishido
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Toshinori Masaoka
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Kengo Yamamoto
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| |
Collapse
|
6
|
Yang HS, LaFrance DR, Hao Y. Elemental Testing Using Inductively Coupled Plasma Mass Spectrometry in Clinical Laboratories. Am J Clin Pathol 2021; 156:167-175. [PMID: 33978166 DOI: 10.1093/ajcp/aqab013] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVES This review aims to describe the principles underlying different types of inductively coupled plasma mass spectrometry (ICP-MS), and major technical advancements that reduce spectral interferences, as well as their suitability and wide applications in clinical laboratories. METHODS A literature survey was performed to review the technical aspects of ICP-MS, ICP-MS/MS, high-resolution ICP-MS, and their applications in disease diagnosis and monitoring. RESULTS Compared to the atomic absorption spectrometry and ICP-optical emission spectrometry, ICP-MS has advantages including improved precision, sensitivity and accuracy, wide linear dynamic range, multielement measurement capability, and ability to perform isotopic analysis. Technical advancements, such as collision/reaction cells, triple quadrupole ICP-MS, and sector-field ICP-MS, have been introduced to improve resolving power and reduce interferences. Cases are discussed that highlight the clinical applications of ICP-MS including determination of toxic elements, quantification of nutritional elements, monitoring elemental deficiency in metabolic disease, and multielement analysis. CONCLUSIONS This review provides insight on the strategies of elemental analysis in clinical laboratories and demonstrates current and emerging clinical applications of ICP-MS.
Collapse
Affiliation(s)
- He S Yang
- Department of Pathology and Laboratory Medicine, Weill Cornell Medicine, New York, NY, USA
- NewYork Presbyterian Hospital, Weill Cornell Medical Campus, New York, NY, USA
| | | | - Ying Hao
- Department of Pathology and Laboratory Medicine, Weill Cornell Medicine, New York, NY, USA
| |
Collapse
|
7
|
Beauchamp JE, Vendittoli PA, Barry J, Pelet S, Belzile EL. Catastrophic failure of femoral stem modular junction when combined with metal-on-metal bearing in comparison to ceramic-on-ceramic: A retrospective cohort study. Orthop Traumatol Surg Res 2021; 107:102749. [PMID: 33316446 DOI: 10.1016/j.otsr.2020.102749] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 08/06/2020] [Accepted: 08/17/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND Metal ion release from total hip arthroplasty's (THA) metal-on-metal (MoM) bearing surfaces or head-neck modular junction (trunnionosis) has been identified as a major cause of adverse reaction to metal debris (ARMD). No study has compared the effects of these bearing couples when combined with modular neck femoral stems (MNFS) (i.e. did a modular CoCr have a higher effect than large MoM bearings on whole blood ion concentrations and ARMD). Therefore we did a retrospective comparative analysis of prospectively collected data aiming to: (1) assess the difference in metal ion release between a group of MoM and CoC bearings implanted with a non-cemented MNFS; (2) compare the ARMD and the related revision rates between the two bearing types; (3) compare the patients' HOOS and Harris Hip scores. HYPOTHESIS Metal ion levels and complications rate will be higher in MoM group. METHODS Thirty hips received the same short MNFS with modular CoCr. Seventeen had CoC bearing (16=36mm) and 13 large diameter head (LDH) MoM bearing (mean=50mm, 44-54mm) Both groups had whole blood Cobalt (Co) and Chromium (Cr) concentrations measurements at last follow up or before revision surgery (if any) and were compared to 41 control individuals without implants. ARMD, revision rates and other complications were censed. Functional outcome differences between operative groups were assessed with HOOS and Harris Hip scores. RESULTS Mean whole blood Co and Cr were 1.9μg/L (0.1-10.6 min-max) and 1.2μg/L (0.2-4.6 min-max) in the CoC group and 12.7μg/L (2.5-40.7 min-max) and 8.2μg/L (2.8-40.6 min-max) for MoM group. Controls presented whole blood Co and Cr levels of 0.2μg/L (0.04-0.2 min-max) and 0.6μg/L (0.1-0.7 min-max) respectively. CoC had significantly higher whole blood metal ion concentrations than controls, while MoM had significantly higher concentrations than both (p<0.001). MoM had a 9/13 (69%) revision rate due to ARMD (with stem-neck junction corrosion and wear were present in all cases) while the CoC had none. Functional scores at last follow up did not statistically differ between groups (Harris: CoC=94.1±8.4 vs MoM 91.8±14.8 (p=0.22) and CoC HOOS 90.2±10.7 vs 75.6±21.7 (p=0.08)). CONCLUSION In our study, MNFS with CoCr modular neck released metal ion systemically, as shown in CoC THAs, but when combined with MoM LDH bearings, that elevation was significantly higher. In MNFS MoM, these high metal ion levels translated into a dramatic ARMD related revision rate where stem-neck junction corrosion and wear were present in all cases. More research is required to understand the effects of MoM bearing on neck-stem junctions, and its mechanisms of corrosion. LEVEL OF EVIDENCE III; retrospective comparative study.
Collapse
Affiliation(s)
- Jean-Etienne Beauchamp
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada.
| | - Pascal-André Vendittoli
- Department of Surgery, Montreal University, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hôpital Maisonneuve-Rosemont (H1T 2M4), 5415 Boulevard L'Assomption, Montreal, QC, Canada
| | - Janie Barry
- Department of Surgery, Montreal University, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hôpital Maisonneuve-Rosemont (H1T 2M4), 5415 Boulevard L'Assomption, Montreal, QC, Canada
| | - Stéphane Pelet
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada; Division of Orthopaedic Surgery, CHU de Québec-Université Laval (G1J 1Z4), 1401, 18e rue, Quebec, QC, Canada
| | - Etienne L Belzile
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada; Division of Orthopaedic Surgery, CHU de Québec-Université Laval (G1J 1Z4), 1401, 18e rue, Quebec, QC, Canada
| |
Collapse
|
8
|
Cobalt–Chromium Dental Alloys: Metal Exposures, Toxicological Risks, CMR Classification, and EU Regulatory Framework. CRYSTALS 2020. [DOI: 10.3390/cryst10121151] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
During the 20th century, metal alloys have assumed an important role as restorative materials. Among existing examples, cobalt–chromium (Co–Cr) alloys increasingly began to be used in medicine and especially in dentistry. Their success is mainly due to their mechanical properties such as stiffness, strength and corrosion resistance, thus allowing a high biocompatibility. There are quite meaningful data on the corrosion and toxicity of Co–Cr alloys for their use in restorative materials such as dental prostheses. Toxicological studies following Co and Cr exposures in the oral cavity are more difficult to conduct because there are many different situations leading to the release of metal ions and wear particles. Furthermore, the links between exposure and the appearance of local or systemic toxicity are not automatic. Since 2017, the European Union (EU) regulatory framework for Co–Cr alloys has been undergoing profound changes. A new EU Medical Devices Regulation (MDR) (2017/745) will be applied in May 2021 with the need to consider that Co metal is a new carcinogenic, mutagenic and toxic to reproduction (CMR) substance. On 18 February 2020, the 14th Adaptation to Technical Progress (ATP14) to the Classification, Labelling and Packaging (CLP) regulation was published, including the harmonised classification for Co metal as a CMR 1B substance. In this context, the use of Co might be forbidden if the medical devices are invasive and as soon as they include more than 0.1% (m/m) Co. This review provides a specific overview on Co–Cr dental alloys in terms of metal ions and wear particles release, toxicological risks, and the actual and new EU regulatory framework.
Collapse
|
9
|
Radice S, Westrick J, Ebinger K, Mathew M, Wimmer MA. In-vitro studies on cells and tissues in tribocorrosion processes: A systematic scoping review. BIOTRIBOLOGY (OXFORD) 2020; 24:100145. [PMID: 33015276 PMCID: PMC7528855 DOI: 10.1016/j.biotri.2020.100145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Tribocorrosion of implants has been widely addressed in the orthopedic and dental research fields. This study is a systematic scoping review about research methods that combine tribocorrosion tests with cells/tissues cultures, aimed to identify related current problems and future challenges. We used 4 different databases to identify 1022 records responding to an articulated keywords search-strategy. After removing the duplicates and the articles that didn't meet the search-criteria, we assessed 20 full-text articles for eligibility. Of the 20 eligible articles, we charted 8 records on cell cultures combined with tribocorrosion tests on implant materials (titanium, CoCrMo, and/or stainless steel). The year of publication ranged from 1991 to 2019. The cell line used was mostly murine. Two records used fretting tests, while 6 used reciprocating sliding with pin-on-disc tribometers. An electrochemical three-electrode setup was used in 4 records. We identified overall two experimental approaches: cells cultured on the metal (5 records), and cells cultured near the metal (3 records). Research activities on tribocorrosion processes in the presence of cells have been undertaken worldwide by a few groups. After a limited initial interest on this topic in the 1990's, research activities have restarted in the last decade, renewing the topic with technologically more advanced setups and analytical tools. We identified the main problems to be the lack of test reproducibility and wear particle characterization. We believe that the main challenges lay in the interdisciplinary approach, the inter-laboratory validation of experiments, and the interpretation of results, particularly in relation to potential clinical significance.
Collapse
Affiliation(s)
- S. Radice
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison St., Chicago, IL 60612, USA
| | - J. Westrick
- Library of Rush University Medical Center, 600 S. Paulina St., Chicago, IL 60612, USA
| | - K. Ebinger
- Klinikum Garmisch-Partenkirche, Auenstraße 6, 82467 Garmisch-Partenkirchen, Germany
| | - M.T. Mathew
- College of Medicine at Rockford, University of Illinois, Department of Biomedical Sciences, 1601 Parkview Avenue, Rockford, IL 61107, USA
| | - M. A. Wimmer
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison St., Chicago, IL 60612, USA
| |
Collapse
|
10
|
Self-reported systemic complaints in patients with metal-on-metal hip arthroplasty. J Orthop 2020; 18:213-217. [PMID: 32071507 DOI: 10.1016/j.jor.2020.01.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 01/24/2020] [Indexed: 12/31/2022] Open
Abstract
Introduction An increase in blood serum metal ion levels is seen after implantation of all metal-on-metal (MoM) hip prosthesis. Systemic complaints contributed to raised cobalt ion concentrations in patients with MoM arthroplasty may lead to a variety of symptoms. The aim of this study is to investigate self-reported systemic complaints in association with cobalt ion concentrations in patients with any type of MoM hip prosthesis. Methods A cohort study was conducted. Patients with both unilateral and bilateral, resurfacing and large head metal on metal total hip arthroplasties (LHMoM THA) were included. Cobalt ion concentrations were measured by inductively coupled plasma mass spectrometry. Based on the known cobalt toxicity symptoms of case-reports and toxicology reports a new non-validated questionnaire was developed. Analysis was performed on two groups; a low cobalt ion concentration group and a high cobalt ion concentration group. Results A total of 62 patients were included with a mean age at surgery of 60.8 ± 9.3 years and a mean follow up of 6.3 ± 1.4 years. Mean cobalt ion concentrations were 104 ± 141 nmol/L (9-833). Based on the different thresholds (120-170 or 220 nmol/L) the low cobalt ion concentration group consisted of 44 (71%), 51 (82%) or 55 (89%) subjects respectively. In the 120 nmol/L and 170 nmol/L thresholds a significant difference in age was found. The composite score for OVS increased from 54% to 57%-68% with rising threshold value, a hint at the correlation between ion concentration and symptom prevalence. Discussion Ocular-vestibular symptoms were more common in high cobalt ion concentration groups for the three threshold levels tested and with increasing prevalence for higher threshold values. With regards to proactively inquired, self-reported symptoms the threshold where effects may be present could be lower than values currently applied in clinical follow-up.
Collapse
|
11
|
Effects of bovine serum albumin and hyaluronic acid on the electrochemical response of a CoCrMo alloy to cathodic and anodic excursions. ACTA ACUST UNITED AC 2019; 5. [PMID: 31828005 DOI: 10.1007/s40735-019-0299-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The problem of wear and corrosion of CoCrMo-implant surfaces in the human body following total joint replacement has been commonly investigated with tribocorrosion tests, using different lubricants meant to simulate the pseudo-synovial fluid. While results considering the synovial fluid components separately have highlighted their individual influence on the tribological performance of CoCrMo-alloy, an understanding about the influence of the synovial fluid components under the electrochemical point of view is missing. This work aims to investigate the effect of bovine serum albumin (BSA) and hyaluronic acid (HA) on electrochemical potential variations of CoCrMo alloys tested in a model synovial fluid. To simulate the environment inside the synovial capsule, the tests were performed inside a CO2 incubator at 37°C. Open circuit potential, electrochemical impedance spectroscopy, cathodic and anodic potentiodynamic measurements were performed with different electrolytes, prepared with cell culture medium (RMPI-1640), BSA and HA. The final CoCrMo-surface was analyzed by SEM/EDS and infrared spectroscopy. The influence of HA on the corrosion of the CoCrMo-alloy depended on the presence of BSA proteins adsorbed on the CoCrMo-surface: EIS and anodic polarization results showed a corrosive action of HA in the absence of adsorbed proteins. In the presence of both BSA and HA, organometallic precipitates were found on the CoCrMo surface following reverse anodic polarization, which remind of corrosion products found in-vivo. These results indicate that HA affects the interaction of CoCrMo implant alloys with protein-containing model synovial fluids, and suggest that HA needs to be considered in tribocorrosion studies for more clinically relevant outcomes.
Collapse
|
12
|
Noli F, Papadopoulos P, Kolias P, Tsiridis E, Papavasiliou K, Sayegh F. Neutron activation analysis for determination of metal ions in biological fluids of patients after CoCrMo arthroplasty. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-019-06718-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
13
|
Jelsma J, Schotanus MG, Senden R, Heyligers IC, Grimm B. Metal ion concentrations after metal-on-metal hip arthroplasty are not correlated with habitual physical activity levels. Hip Int 2019; 29:638-646. [PMID: 30479165 DOI: 10.1177/1120700018814225] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Metal-on-metal (MoM) hip arthroplasties have shown high clinical failure rates with many patients at risk for a revision and under surveillance for high metal ion concentrations. Implant wear releasing such ions is assumed to be a function of use, i.e. the patient's physical activity. This study aimed to assess whether habitual physical activity levels of MoM patients are correlated with metal ion concentrations and are higher in patients with high (at risk) than in patients with low (safe) metal ion concentrations. METHODS A cohort study was conducted of patients with any type of MoM hip prosthesis. Metal ion concentrations were determined using ICP-MS. Habitual physical activity of subjects was measured in daily living using an acceleration-based activity monitor. Outcome consisted of quantitative and qualitative activity parameters. RESULTS In total, 62 patients were included. Mean age at surgery was 60.8 ± 9.3 years and follow-up was 6.3 ± 1.4 years. Cobalt concentrations were highly elevated overall (112.4 ± 137.9 nmol/L) and significantly more in bilateral (184.8 ± 106.5 nmol/L) than in unilateral cases (87.8 ± 139.4 nmol/L). No correlations were found between physical activity parameters and metal ion concentrations. Subgroup analysis of patients with low versus high cobalt concentration showed no significant differences in habitual physical activity. DISCUSSION No correlation was found between physical activity levels and metal ion concentrations. Implant use by normal habitual activities of daily living seems not to influence metal ion concentrations.
Collapse
Affiliation(s)
- Jetse Jelsma
- Department of Orthopaedics, Zuyderland Medical Centre, Sittard-Geleen/Heerlen, The Netherlands
| | - Martijn Gm Schotanus
- Department of Orthopaedics, Zuyderland Medical Centre, Sittard-Geleen/Heerlen, The Netherlands
| | - Rachel Senden
- Department of Orthopaedics, Zuyderland Medical Centre, Sittard-Geleen/Heerlen, The Netherlands
| | - Ide C Heyligers
- Department of Orthopaedics, Zuyderland Medical Centre, Sittard-Geleen/Heerlen, The Netherlands
| | - Bernd Grimm
- Department of Orthopaedics, Zuyderland Medical Centre, Sittard-Geleen/Heerlen, The Netherlands
| |
Collapse
|
14
|
Abstract
Inductively coupled plasma mass spectrometry (ICP-MS) is an analytical technique that can be used to measure elements at trace levels in biological fluids. Although older techniques such as atomic absorption and atomic emission are still in use by some laboratories, there has been a slow shift toward ICP-MS, particularly in the last decade. As this shift is likely to continue, clinical scientists should be aware of the analytical aspects of ICP-MS, as well as the potential for both spectroscopic and non-spectroscopic interference, and strategies that can be employed to eliminate or mitigate these issues.
Collapse
|
15
|
Cr(VI)‐induced genotoxicity and cell cycle arrest in human osteoblast cell line MG‐63. J Appl Toxicol 2019; 39:1057-1065. [DOI: 10.1002/jat.3793] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Revised: 01/25/2019] [Accepted: 02/07/2019] [Indexed: 11/07/2022]
|
16
|
Vierra BM, Blumenthal SR, Amanatullah DF. Modularity in Total Hip Arthroplasty: Benefits, Risks, Mechanisms, Diagnosis, and Management. Orthopedics 2017; 40:355-366. [PMID: 28598491 DOI: 10.3928/01477447-20170606-01] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2016] [Accepted: 11/07/2016] [Indexed: 02/03/2023]
Abstract
Modular implants are currently widely used in total hip arthroplasty because they give surgeons versatility during the operation, allow for easier revision surgery, and can be adjusted to better fit the anatomy of the specific patient. However, modular implants, specifically those that have metal-on-metal junctions, are susceptible to crevice and fretting corrosion. This can ultimately cause implant failure, inflammation, and adverse local tissue reaction, among other possible side effects. Surgeons should be aware of the possibility of implant corrosion and should follow a set of recommended guidelines to systematically diagnose and treat patients with corroded implants. Ultimately, surgeons will continue to use modular implants because of their widespread benefits. However, more research is needed to determine how to minimize corrosion and the negative side effects that have been associated with modular junctions in total hip arthroplasty. [Orthopedics. 2017; 40(6):355-366.].
Collapse
|
17
|
Speer RM, The T, Xie H, Liou L, Adam RM, Wise JP. The Cytotoxicity and Genotoxicity of Particulate and Soluble Cobalt in Human Urothelial Cells. Biol Trace Elem Res 2017; 180:48-55. [PMID: 28324276 DOI: 10.1007/s12011-017-0989-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Accepted: 03/02/2017] [Indexed: 11/25/2022]
Abstract
Cobalt use is increasing particularly due to its use as one of the primary metals in cobalt-chromium-molybdenum (CoCrMo) metal-on-metal prosthetics. CoCrMo is a high-strength, wear-resistant alloy with reduced risk for prosthetic loosening and device fracture. More than 500,000 people receive hip implants each year in the USA which puts them at potential risk for exposure to metal ions and particles released by the prosthetic implants. Data show cobalt ions released from prosthetics reach the bloodstream and accumulate in the bladder. As patients with failed hip implants show increased urinary and blood cobalt levels, no studies have considered the effects of cobalt on human urothelial cells. Accordingly, we investigated the cytotoxic and genotoxic effects of particulate and soluble cobalt in urothelial cells. Exposure to both particulate and soluble cobalt resulted in a concentration-dependent increase in cytotoxicity, genotoxicity, and intracellular cobalt ions. Based on intracellular cobalt ion levels, we found, when compared to particulate cobalt, soluble cobalt was more cytotoxic, but induced similar levels of genotoxicity. Interestingly, at similar intracellular cobalt ion concentrations, soluble cobalt induced cell cycle arrest indicated by a lack of metaphases not observed after particulate cobalt treatment. These data indicate that cobalt compounds are cytotoxic and genotoxic to human urothelial cells and solubility may play a key role in cobalt-induced toxicity.
Collapse
Affiliation(s)
- Rachel M Speer
- Wise Laboratory of Environmental and Genetic Toxicology, University of Louisville, 505 S. Hancock St, CTRB rm 522, Louisville, KY, 40292, USA
| | - Therry The
- Wise Laboratory of Environmental and Genetic Toxicology, University of Louisville, 505 S. Hancock St, CTRB rm 522, Louisville, KY, 40292, USA
- Maine General Health, Alfonso Center of Health, Histology and Cytology Laboratory, 35 Medical Center Parkway, Augusta, ME, 04330, USA
| | - Hong Xie
- Wise Laboratory of Environmental and Genetic Toxicology, University of Louisville, 505 S. Hancock St, CTRB rm 522, Louisville, KY, 40292, USA
- Toxikon Corp, 15 Wiggins Avenue, Bedford, MA, 01730, USA
| | - Louis Liou
- Cambridge Health Alliance Somerville Hospital, 230 Highland Avenue, 4th Floor South Building, Somerville, MA, 02143, USA
| | - Rosalyn M Adam
- Department of Urology, Enders Research Building, Rm 1061.1, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA
| | - John Pierce Wise
- Wise Laboratory of Environmental and Genetic Toxicology, University of Louisville, 505 S. Hancock St, CTRB rm 522, Louisville, KY, 40292, USA.
| |
Collapse
|
18
|
Vasconcelos DM, Santos SG, Lamghari M, Barbosa MA. The two faces of metal ions: From implants rejection to tissue repair/regeneration. Biomaterials 2016; 84:262-275. [DOI: 10.1016/j.biomaterials.2016.01.046] [Citation(s) in RCA: 64] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 01/20/2016] [Accepted: 01/21/2016] [Indexed: 12/20/2022]
|
19
|
Slonimsky E, Kushnir T, Kadar A, Menahem A, Grundshtein A, Dekel S, Eshed I. Bilateral total hip replacement: periprosthetic pseudotumor collections are more prevalent in metal-on-metal implants compared to non-metal-on-metal ones. Acta Radiol 2016; 57:463-7. [PMID: 25940064 DOI: 10.1177/0284185115583930] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Accepted: 03/31/2015] [Indexed: 12/12/2022]
Abstract
BACKGROUND Metal-on-metal (MoM) hip prostheses were shown to have high failure rates including the formation of periprosthetic cystic masses called periprosthetic pseudotumor collections (PPCs). PURPOSE To compare MRI prevalence and size of PPCs in patients after bilateral total-hip-replacement (THR) in which at least one hip was replaced by a MoM prosthesis. MATERIAL AND METHODS All sequential MRI examinations of patients with bilateral THR in which at least one is MoM (2010-2013) were retrospectively evaluated. MRIs were analyzed separately by two readers for the presence and size of PPCs. These were compared between MoM and non-MoM implants and between patients with unilateral or bilateral-MoM prostheses. Blood metal ion levels were also compared. RESULTS Seventy hips of 35 patients (male:female ratio, 9:26; mean age, 64 years; age range, 35-82 years) were assessed. Sixteen patients (45%) underwent bilateral MoM-THRs and 19 (55%) had one MoM and the other non-MoM, yielding 51 MoM THRs and 19 non-MoM THRs. Twenty-eight PPCs were detected in 19 patients (54%): 26 in MoM THRs (51%) and two in non-MoM THRs (10.5%, P = 0.00009). The mean PPC volume in the MoM implants (107 mm(3)) was higher than that of the non-MoM implants (18 mm(3), P = 0.49). Cobalt/chromium blood levels were 78 µg/L/25 µg/L for bilateral MoM THRs and 21 µg/L/10 µg/L for unilateral MoM implants (P = 0.1 and 0.16, respectively). CONCLUSION PPCs are more prevalent in MoM THRs compared to non-MoM THRs. Larger PPC volumes and higher blood metal ion levels were detected in patients with bilateral MoM THRs compared to unilateral MoM THRs (P > 0.05).
Collapse
Affiliation(s)
- Einat Slonimsky
- Department of Diagnostic Imaging, Sheba Medical Center, affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Israel
| | - Tammar Kushnir
- Department of Diagnostic Imaging, Sheba Medical Center, affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Israel
| | - Assaf Kadar
- Department of Orthopedic Surgery, Tel Aviv Sourasky Medical Center, affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Aharon Menahem
- Department of Orthopedic Surgery, Tel Aviv Sourasky Medical Center, affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Alon Grundshtein
- Department of Orthopedic Surgery, Tel Aviv Sourasky Medical Center, affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Shmuel Dekel
- Department of Orthopedic Surgery, Assuta Medical Center, Tel Aviv, Israel
| | - Iris Eshed
- Department of Diagnostic Imaging, Sheba Medical Center, affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Israel
| |
Collapse
|
20
|
In Vitro Analyses of the Toxicity, Immunological, and Gene Expression Effects of Cobalt-Chromium Alloy Wear Debris and Co Ions Derived from Metal-on-Metal Hip Implants. LUBRICANTS 2015. [DOI: 10.3390/lubricants3030539] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
21
|
Hip arthroplasty with high chromium and cobalt blood levels – Case report of a patient followed during pregnancy and lactation period. Reprod Toxicol 2015; 53:51-3. [DOI: 10.1016/j.reprotox.2015.03.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2014] [Revised: 03/06/2015] [Accepted: 03/20/2015] [Indexed: 11/24/2022]
|
22
|
CoCr wear particles generated from CoCr alloy metal-on-metal hip replacements, and cobalt ions stimulate apoptosis and expression of general toxicology-related genes in monocyte-like U937 cells. Toxicol Appl Pharmacol 2014; 281:125-35. [DOI: 10.1016/j.taap.2014.09.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2014] [Revised: 08/27/2014] [Accepted: 09/22/2014] [Indexed: 12/28/2022]
|
23
|
Matusiewicz H. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review. Acta Biomater 2014; 10:2379-403. [PMID: 24565531 DOI: 10.1016/j.actbio.2014.02.027] [Citation(s) in RCA: 124] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 12/04/2013] [Accepted: 02/13/2014] [Indexed: 02/06/2023]
Abstract
Metal ion release from metallic materials, e.g. metallic alloys and pure metals, implanted into the human body in dental and orthopedic surgery is becoming a major cause for concern. This review briefly provides an overview of both metallic alloys and pure metals used in implant materials in dental and orthopedic surgery. Additionally, a short section is dedicated to important biomaterials and their corrosive behavior in both real solutions and various types of media that model human biological fluids and tissues. The present review gives an overview of analytical methods, techniques and different approaches applied to the measurement of in vivo trace metals released into body fluids and tissues from patients carrying metal-on-metal prostheses and metal dental implants. Reference levels of ion concentrations in body fluids and tissues that have been determined by a host of studies are compiled, reviewed and presented in this paper. Finally, a collection of published clinical data on in vivo released trace metals from metallic medical implants is included.
Collapse
|
24
|
Mantripragada VP, Lecka-Czernik B, Ebraheim NA, Jayasuriya AC. An overview of recent advances in designing orthopedic and craniofacial implants. J Biomed Mater Res A 2013; 101:3349-64. [PMID: 23766134 PMCID: PMC4854641 DOI: 10.1002/jbm.a.34605] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Revised: 01/11/2013] [Accepted: 01/11/2013] [Indexed: 01/22/2023]
Abstract
Great deal of research is still going on in the field of orthopedic and craniofacial implant development to resolve various issues being faced by the industry today. Despite several disadvantages of the metallic implants, they continue to be used, primarily because of their superior mechanical properties. In order to minimize the harmful effects of the metallic implants and its by-products, several modifications are being made to these materials, for instance nickel-free stainless steel, cobalt-chromium and titanium alloys are being introduced to eliminate the toxic effects of nickel being released from the alloys, introduce metallic implants with lower modulus, reduce the cost of these alloys by replacing rare elements with less expensive elements etc. New alloys like tantalum, niobium, zirconium, and magnesium are receiving attention given their satisfying mechanical and biological properties. Non-oxide ceramics like silicon nitride and silicon carbide are being currently developed as a promising implant material possessing a combination of properties such as good wear and corrosion resistance, increased ductility, good fracture and creep resistance, and relatively high hardness in comparison to alumina. Polymer/magnesium composites are being developed to improve mechanical properties as well as retain polymer's property of degradation. Recent advances in orthobiologics are proving interesting as well. This paper thus deals with the latest improvements being made to the existing implant materials and includes new materials being introduced in the field of biomaterials.
Collapse
|
25
|
Raghunathan VK, Devey M, Hawkins S, Hails L, Davis SA, Mann S, Chang IT, Ingham E, Malhas A, Vaux DJ, Lane JD, Case CP. Influence of particle size and reactive oxygen species on cobalt chrome nanoparticle-mediated genotoxicity. Biomaterials 2013; 34:3559-70. [PMID: 23433773 DOI: 10.1016/j.biomaterials.2013.01.085] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2013] [Accepted: 01/28/2013] [Indexed: 02/06/2023]
Abstract
Patients with cobalt chrome (CoCr) metal-on-metal (MOM) implants may be exposed to a wide size range of metallic nanoparticles as a result of wear. In this study we have characterised the biological responses of human fibroblasts to two types of synthetically derived CoCr particles [(a) from a tribometer (30 nm) and (b) thermal plasma technology (20, 35, and 80 nm)] in vitro, testing their dependence on nanoparticle size or the generation of oxygen free radicals, or both. Metal ions were released from the surface of nanoparticles, particularly from larger (80 nm) particles generated by thermal plasma technology. Exposure of fibroblasts to these nanoparticles triggered rapid (2 h) generation of reactive oxygen species (ROS) that could be eliminated by inhibition of NADPH oxidase, suggesting that it was mediated by phagocytosis of the particles. The exposure also caused a more prolonged, MitoQ sensitive production of ROS (24 h), suggesting involvement of mitochondria. Consequently, we recorded elevated levels of aneuploidy, chromosome clumping, fragmentation of mitochondria and damage to the cytoskeleton particularly to the microtubule network. Exposure to the nanoparticles resulted in misshapen nuclei, disruption of mature lamin B1 and increased nucleoplasmic bridges, which could be prevented by MitoQ. In addition, increased numbers of micronuclei were observed and these were only partly prevented by MitoQ, and the incidence of micronuclei and ion release from the nanoparticles were positively correlated with nanoparticle size, although the cytogenetic changes, modifications in nuclear shape and the amount of ROS were not. These results suggest that cells exhibit diverse mitochondrial ROS-dependent and independent responses to CoCr particles, and that nanoparticle size and the amount of metal ion released are influential.
Collapse
|
26
|
Gill IPS, Webb J, Sloan K, Beaver RJ. Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation. ACTA ACUST UNITED AC 2012; 94:895-900. [PMID: 22733942 DOI: 10.1302/0301-620x.94b7.29122] [Citation(s) in RCA: 174] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
We present a series of 35 patients (19 men and 16 women) with a mean age of 64 years (36.7 to 75.9), who underwent total hip replacement using the ESKA dual-modular short stem with metal on-polyethylene bearing surfaces. This implant has a modular neck section in addition to the modular head. Of these patients, three presented with increasing post-operative pain due to pseudotumour formation that resulted from corrosion at the modular neck-stem junction. These patients underwent further surgery and aseptic lymphocytic vaculitis associated lesions were demonstrated on histological analysis. Retrieval analysis of two modular necks showed corrosion at the neck-stem taper. Blood cobalt and chromium levels were measured at a mean of nine months (3 to 28) following surgery. These were compared with the levels in seven control patients (three men and four women) with a mean age of 53.4 years (32.1 to 64.1), who had an identical prosthesis and articulation but with a prosthesis that had no modularity at neck-stem junction. The mean blood levels of cobalt in the study group were raised at 50.75 nmol/l (5 to 145) compared with 5.6 nmol/l (2 to 13) in control patients. Corrosion at neck-stem tapers has been identified as an important source of metal ion release and pseudotumour formation requiring revision surgery. Finite element modelling of the dual modular stem demonstrated high stresses at the modular stem-neck junction. Dual modular cobalt-chrome hip prostheses should be used with caution due to these concerns.
Collapse
Affiliation(s)
- I P S Gill
- Royal Perth Hospital, 197 Wellington Street, Perth, Western Australia 6000, Australia
| | | | | | | |
Collapse
|
27
|
Fritzsche J, Borisch C, Schaefer C. Case report: High chromium and cobalt levels in a pregnant patient with bilateral metal-on-metal hip arthroplasties. Clin Orthop Relat Res 2012; 470:2325-31. [PMID: 22692823 PMCID: PMC3392404 DOI: 10.1007/s11999-012-2398-0] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2012] [Accepted: 05/10/2012] [Indexed: 01/31/2023]
Abstract
BACKGROUND Metal-on-metal bearings frequently are used in young patients leading to the concern that disseminated metals such as chromium (Cr) and cobalt (Co) as the main constituents could affect pregnancies. CASE DESCRIPTION We describe a 41-year-old patient with bilateral metal-on-metal hip arthroplasties, a recurrent pseudotumor, and extremely high blood levels (Cr 39 μg/L, Co 138 μg/L) at 12 gestational weeks. At different gestational weeks, maternal blood, aspirate of the pseudotumor, and amniotic fluid were analyzed for Cr and Co. Therapy with chelating agents was not recommended because the mother showed no symptoms of toxicity and the safety of chelating therapy during pregnancy is not established. At 38 weeks of gestation, a healthy male infant was delivered with elevated Cr and Co cord blood levels. At the age of 8 weeks, the infant's Cr was comparable to the cord blood level, whereas the Co decreased considerably without treatment. At the age of 14 weeks, the infant's development was seemingly uneventful and no signs of toxicity were obvious. LITERATURE REVIEW Carcinogenic, mutagenic, and teratogenic potentials of these metals have been suggested. However, we found no published clinical observations in context with pregnancies of women with hip arthroplasties using metal-on-metal implants. To our knowledge, this is the first report of such high levels of Cr and Co in a human pregnancy. PURPOSES AND CLINICAL RELEVANCE Although we cannot generalize from one case, the seemingly uneventful outcome of this pregnancy may reassure colleagues when counseling patients with high ion levels whether to carry a pregnancy to term.
Collapse
Affiliation(s)
- Juliane Fritzsche
- Pharmakovigilanz- und Beratungszentrum für Embryonaltoxikologie (Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy), Institut für Klinische Pharmakologie und Toxikologie, Charité Universitätsmedizin Berlin, Spandauer Damm 130, Haus 10, D-14050 Berlin, Germany
| | - Cornelia Borisch
- Pharmakovigilanz- und Beratungszentrum für Embryonaltoxikologie (Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy), Institut für Klinische Pharmakologie und Toxikologie, Charité Universitätsmedizin Berlin, Spandauer Damm 130, Haus 10, D-14050 Berlin, Germany
| | - Christof Schaefer
- Pharmakovigilanz- und Beratungszentrum für Embryonaltoxikologie (Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy), Institut für Klinische Pharmakologie und Toxikologie, Charité Universitätsmedizin Berlin, Spandauer Damm 130, Haus 10, D-14050 Berlin, Germany
| |
Collapse
|
28
|
Metal allergy and systemic contact dermatitis: an overview. Dermatol Res Pract 2012; 2012:749561. [PMID: 22693488 PMCID: PMC3369403 DOI: 10.1155/2012/749561] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2012] [Accepted: 04/06/2012] [Indexed: 12/03/2022] Open
Abstract
Contact dermatitis is produced by external skin exposure to an allergen, but sometimes a systemically administered allergen may reach the skin and remain concentrated there with the aid of the circulatory system, leading to the production of systemic contact dermatitis (SCD). Metals such as nickel, cobalt, chromium, and zinc are ubiquitous in our environment. Metal allergy may result in allergic contact dermatitis and also SCD. Systemic reactions, such as hand dermatitis or generalized eczematous reactions, can occur due to dietary nickel or cobalt ingestion. Zinc-containing dental fillings can induce oral lichen planus, palmoplantar pustulosis, and maculopapular rash. A diagnosis of sensitivity to metal is established by epicutaneous patch testing and oral metal challenge with metals such as nickel, cobalt, chromium, and zinc. In vitro tests, such as the lymphocyte stimulating test (LST), have some advantages over patch testing to diagnose allergic contact dermatitis. Additionally, the determination of the production of several cytokines by primary peripheral blood mononuclear cell cultures is a potentially promising in vitro method for the discrimination of metal allergies, including SCD, as compared with the LST.
Collapse
|
29
|
Akbar M, Fraser AR, Graham GJ, Brewer JM, Grant MH. Acute inflammatory response to cobalt chromium orthopaedic wear debris in a rodent air-pouch model. J R Soc Interface 2012; 9:2109-19. [PMID: 22513721 DOI: 10.1098/rsif.2012.0006] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
This study used a rodent air-pouch model to assess the acute inflammatory response to cobalt-chromium (CoCr) alloy wear debris from a metal-on-metal hip resurfacing implant that may contribute to joint failure. Air-pouches were injected with either sterile phosphate-buffered saline, 1 μg lipopolysaccharide (LPS) or 2.5 mg CoCr wear debris. The in situ inflammatory response was monitored 4, 24, 48 and 72 h and 7 days later. A flow cytometric analysis of the inflammatory exudates showed that CoCr wear debris induced a different inflammatory pattern compared with LPS. LPS induced a strong early (4 h) neutrophil influx, with monocyte/macrophage influx peaking at 24 h, whereas CoCr wear debris initiated almost equal numbers of early monocyte/macrophage and neutrophil recruitment. Histological analyses also showed CoCr debris accumulated in the pouch wall and this was accompanied by vast cellular infiltration and fibrosis around the debris throughout the duration of the experiment. Assessment of inflammatory gene transcripts from air-pouch tissue showed that CoCr wear debris increased the expression of cytokines involved in promoting inflammation and fibrosis (IL-1β, TGF-β) and chemokines that promote the recruitment of neutrophils and monocytes/macrophages (CXCL2 and CCL2). The data suggest that inflammatory responses to CoCr debris induce a specific acute process in which the recruitment of monocytes/macrophages is key.
Collapse
Affiliation(s)
- Moeed Akbar
- Bioengineering Unit, University of Strathclyde, Wolfson Centre, Glasgow, UK
| | | | | | | | | |
Collapse
|
30
|
Gao X, He RX, Yan SG, Wu LD. Dermatitis associated with chromium following total knee arthroplasty. J Arthroplasty 2011; 26:665.e13-6. [PMID: 20663637 DOI: 10.1016/j.arth.2010.06.002] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2010] [Accepted: 06/09/2010] [Indexed: 02/01/2023] Open
Abstract
All metal implants release metal ions because of corrosion. Although 20% to 25% of patients develop metal sensitivity after total joint arthroplasty, which is 10% higher than that in the general population, only very few highly susceptible patients exhibit symptoms. Even patients with known metal allergy often do not react to their metal prosthesis. Systemic allergic contact dermatitis is particularly uncommon with total knee arthroplasty because there is no metal-on-metal contact between the femoral and tibial components. We present a case report of 62-year-old man with dermatitis most likely caused by chromium after total knee arthroplasty and review the relevant literature. Although this complication is very rare, it sometimes can be painful enough for the patient to undergo revision surgery.
Collapse
Affiliation(s)
- Xiang Gao
- Department of Orthopaedic Surgery, Second Affiliated Hospital, Medical School of Zhejiang University, Hangzhou, China
| | | | | | | |
Collapse
|
31
|
Akbar M, Brewer JM, Grant MH. Effect of chromium and cobalt ions on primary human lymphocytesin vitro. J Immunotoxicol 2011; 8:140-9. [DOI: 10.3109/1547691x.2011.553845] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
|