1
|
Lu F, Samuel A, Merrill C, Medellin A, Burrowes DP, Wilson SR. Synoptic Reporting of Focal Liver Masses in at Risk Patients: Algorithmic Diagnosis and CEUS LI-RADS. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:563-571. [PMID: 38088445 DOI: 10.1002/jum.16389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 11/24/2023] [Indexed: 02/08/2024]
Abstract
OBJECTIVES Reporting contrast-enhanced ultrasound (CEUS) for focal liver masses in at risk patients is a challenging task. Traditionally used prose reporting (PR) is inconsistent and lacks standardization. We propose synoptic reporting (SR), encompassing algorithmic interpretation and liver imaging and reporting data system (LI-RADS) categorization. METHODS A software worksheet from Kailo Medical (Melbourne, AU), incorporates the CEUS algorithm for liver interpretation and CEUS LI-RADS categorization. Part 1. Feasibility of SR: twenty participants of varying experience were presented a brief lecture on SR, algorithmic approach to liver mass interpretation, and CEUS LI-RADS categorization. Ten representative liver masses were shown as unknown cases. Participants inputted data into SR worksheets. Results and LI-RADS category were generated solely by SR. Data were categorized as "correct" or "incorrect." Part 2. Prospective Analysis: Ninety-one patients for SR and 56 for PR, all were tested for completeness, efficiency, and user satisfaction. RESULTS Part 1: Junior participants, pass rate 81.6%, and senior participants, pass rate 83.3% showed no difference in performance. Part 2: Completeness: SR 98.4% and PR 87.0%. Efficiency: Average total time to completion: SR 11 minutes and PR 20 minutes. User satisfaction: Ultrasound technologists, all referring physicians, and six out of seven radiologists preferred SR over PR. Major benefits cited were total time saved, consistency and accuracy in documentation, and report completeness. CONCLUSIONS SR is a reliable and useful tool in clinical practice to report liver masses on ultrasound and assign an appropriate LI-RADS categorization and management pathway. This ultimately improves communication with referring clinicians and leads to better patient outcomes.
Collapse
Affiliation(s)
- Fangshi Lu
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Anna Samuel
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Christine Merrill
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Alex Medellin
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - David P Burrowes
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Stephanie R Wilson
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
- Department of Medicine, Division of Gastroenterology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
2
|
Merrill CD, Samuel AS, Barr RG, Wilson SR. Focal liver lesions in the setting of chronic liver disease. MULTIPARAMETRIC ULTRASOUND FOR THE ASSESSMENT OF DIFFUSE LIVER DISEASE 2024:213-236. [DOI: 10.1016/b978-0-323-87479-3.00022-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
3
|
Merrill C, Samuel A, Gupta S, Wilson SR. A Novel Technology for Resolution of CEUS Imaging Problems in Patients With High BMI and Fatty Liver. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:2603-2614. [PMID: 37401549 DOI: 10.1002/jum.16296] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 06/06/2023] [Accepted: 06/13/2023] [Indexed: 07/05/2023]
Abstract
OBJECTIVES In high-BMI patients with and without fatty liver, we evaluate performance of a commercially available specially designed ultrasound probe (SDP) for scanning at depth. Greyscale and contrast-enhanced ultrasound (CEUS) capability of SDP for parenchymal assessment and liver mass characterization, emphasizing HCC, is compared with standard curvilinear probes. METHODS This retrospective study included 60 patients. Fifty-five with measured BMI included 46/55 (84%) overweight or obese, and 9/55(16%) in the normal range with severe fatty liver. Fifty-six patients with focal liver abnormality included 37 with a mass and 19 with post-ablative treatment site. Masses included 23 confirmed malignancies, 15 HCC, 4 ICC, and 4 metastases. SDP followed suboptimal ultrasound using a standard probe. Images with varying fat content were compared for depth of penetration on greyscale and ability of CEUS to diagnose tumors. RESULTS SDP showed statistically significant improvement P = <.05 in CEUS penetration for all degrees of fatty liver (mild, moderate, and severe). In malignant tumors, SDP improved detection of lesion washout in the portal venous/late phase (PVP/LP) at depth >10 cm, and in all malignant masses (P < .05). Fifteen confirmed deep HCC showed arterial phase hyperenhancement on standard probe in 10/15 (67%) and 15/15 (100%) on SDP. PVP/LP washout on standard probe was shown in 4/15 (26%) and on SDP, 14/15, (93%). Therefore, 93% of LR-5 tumors were diagnosed with SDP. Removing necessity for biopsy. CONCLUSIONS Metabolic syndrome and obesity challenge ultrasound, especially CEUS. SDP overcame limitations of standard probes for CEUS penetration especially in fatty liver. SDP was optimal for the liver mass characterization by detecting washout.
Collapse
Affiliation(s)
- Christina Merrill
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Anna Samuel
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Saransh Gupta
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Stephanie R Wilson
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
- Department of Medicine, Division of Gastroenterology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
4
|
Barr RG, Wilson SR, Lyshchik A, McCarville B, Darge K, Grant E, Robbin M, Wilmann JK, Chong WK, Fleischer A, Paltiel HJ. Contrast -Enhanced Ultrasound: State of the Art in North America. Ultrasound Q 2021; 36:206-217. [PMID: 32890323 DOI: 10.1097/ruq.0000000000000514] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The Society of Radiologists in Ultrasound convened a panel of specialists in contrast-enhanced ultrasound (CEUS) to produce a white paper on noncardiac CEUS in North America. The panel met in Chicago, Illinois, on October 24 and 25, 2017. The recommendations are based on analysis of current literature and common practice strategies and are thought to represent a reasonable approach to introduce the advantages of this safe and noninvasive technique for the benefit of our patients. Characterization of liver nodules, and pediatric vascular and intravesicular applications comprise the approved indications for CEUS in the United States. They, along with the very successful off-label use of CEUS for the kidney, are included in this publication.Other off-label uses are presented with emphasis on their value and literature support in the online version.
Collapse
Affiliation(s)
| | | | | | | | - Kassa Darge
- Children's Hospital of Philadelphia, Philadelphia, PA
| | - Edward Grant
- University of Southern California, Los Angeles, CA
| | | | | | | | | | | |
Collapse
|
5
|
Schwarz S, Clevert DA, Ingrisch M, Geyer T, Schwarze V, Rübenthaler J, Armbruster M. Quantitative Analysis of the Time-Intensity Curve of Contrast-Enhanced Ultrasound of the Liver: Differentiation of Benign and Malignant Liver Lesions. Diagnostics (Basel) 2021; 11:diagnostics11071244. [PMID: 34359327 PMCID: PMC8304201 DOI: 10.3390/diagnostics11071244] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 07/08/2021] [Accepted: 07/09/2021] [Indexed: 02/07/2023] Open
Abstract
Background: To evaluate the diagnostic accuracy of quantitative perfusion parameters in contrast-enhanced ultrasound to differentiate malignant from benign liver lesions. Methods: In this retrospective study 134 patients with a total of 139 focal liver lesions were included who underwent contrast enhanced ultrasound (CEUS) between 2008 and 2018. All examinations were performed by a single radiologist with more than 15 years of experience using a second-generation blood pool contrast agent. The standard of reference was histopathology (n = 60), MRI or CT (n = 75) or long-term CEUS follow up (n = 4). For post processing regions of interests were drawn both inside of target lesions and the liver background. Time–intensity curves were fitted to the CEUS DICOM dataset and the rise time (RT) of contrast enhancement until peak enhancement, and a late-phase ratio (LPR) of signal intensities within the lesion and the background tissue, were calculated and compared between malignant and benign liver lesion using Student’s t-test. Quantitative parameters were evaluated with respect to their diagnostic accuracy using receiver operator characteristic curves. Both features were then combined in a logistic regression model and the cumulated accuracy was assessed. Results: RT of benign lesions (14.8 ± 13.8 s, p = 0.005), and in a subgroup analysis, particular hemangiomas (23.4 ± 16.2 s, p < 0.001) differed significantly to malignant lesions (9.3 ± 3.8 s). The LPR was significantly different between benign (1.59 ± 1.59, p < 0.001) and malignant lesions (0.38 ± 0.23). Logistic regression analysis with RT and LPR combined showed a high diagnostic accuracy of quantitative CEUS parameters with areas under the curve of 0.923 (benign vs. malignant) and 0.929 (hemangioma vs. malignant. Conclusions: Quantified CEUS parameters are helpful to differentiate malignant from benign liver lesions, in particular in case of atypical hemangiomas.
Collapse
|
6
|
Hwang JA, Jeong WK, Min JH, Kim YY, Heo NH, Lim HK. Sonazoid-enhanced ultrasonography: comparison with CT/MRI Liver Imaging Reporting and Data System in patients with suspected hepatocellular carcinoma. Ultrasonography 2021; 40:486-498. [PMID: 33745266 PMCID: PMC8446493 DOI: 10.14366/usg.20120] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Accepted: 01/15/2021] [Indexed: 12/14/2022] Open
Abstract
Purpose The aim of this study was to evaluate the association of contrast-enhanced ultrasound (CEUS) features using Sonazoid for liver nodules with Liver Imaging Reporting and Data System (LI-RADS) categories and to identify the usefulness of Kupffer-phase images. Methods This retrospective study was conducted in 203 patients at high risk of hepatocellular carcinoma (HCC) who underwent CEUS with Sonazoid from 2013 to 2016. Nodule enhancement in the arterial, portal venous, late, and Kupffer phases; CEUS LI-RADS major features; and Kupffer-phase defects were evaluated. According to the computed tomography/magnetic resonance imaging (CT/MRI) LI-RADS v2018, all nodules were assigned an LR category (n=4/33/99/67 for LR-M/3/4/5) and comparisons across LR categories were made. We defined modified CEUS LI-RADS as using Kupffer-phase defects as an alternative to late and mild washout in CEUS LI-RADS and compared the diagnostic performance for HCC. Results On CEUS of 203 nodules, 89.6% of CT/MRI LR-5 and 85.9% of LR-4 nodules showed hyperenhancement in the arterial phase, while 57.6% of LR-3 nodules showed hyperenhancement. Among the CT/MRI LR-5 nodules that showed arterial phase hyperenhancement or isoenhancement, 59.7% showed hypoenhancing changes from the portal venous phase, 23.9% from the late phase, and 13.4% additionally in the Kupffer phase. The modified CEUS LI-RADS showed higher sensitivity than CEUS LI-RADS (83.2% vs. 74.2%, P=0.008) without compromising specificity (63.6% vs. 69.7%, P=0.500). Conclusion The Kupffer phase best shows hypoenhancing changes in LR-5 lesions and is expected to improve the sensitivity for HCC in high-risk patients.
Collapse
Affiliation(s)
- Jeong Ah Hwang
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Woo Kyoung Jeong
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Ji Hye Min
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yeun-Yoon Kim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Nam Hun Heo
- Clinical Trial Center, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea
| | - Hyo Keun Lim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
7
|
Faustino CB, Ventura C, Portugal MFC, Brunheroto A, Teivelis MP, Wolosker N. Experiência inicial com ultrassom Doppler com contraste por microbolhas em adição ao ultrassom Doppler convencional para seguimento de correção endovascular de aneurisma de aorta abdominal. J Vasc Bras 2021; 20:e20200093. [PMID: 35515084 PMCID: PMC9045535 DOI: 10.1590/1677-5449.200093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Accepted: 09/11/2020] [Indexed: 12/04/2022] Open
Abstract
Background Microbubble contrast enhanced ultrasound (CEUS) is an accurate diagnostic method for follow-up after endovascular abdominal aortic aneurysm repair (EVAR) that has been well-established in international studies. However, there are no Brazilian studies that focus on this follow-up method. Objectives The objective of this study was to report initial experience with CEUS at a tertiary hospital, comparing the findings of CEUS with those of conventional Doppler ultrasound (DUS), with the aim of determining whether addition of contrast to the standard ultrasonographic control protocol resulted in different findings. Methods From 2015 to 2017, 21 patients in follow-up after EVAR underwent DUS followed by CEUS. The findings of these examinations were analyzed in terms of identification of complications and their capacity to identify the origin of endoleaks. Results There was evidence of complications in 10 of the 21 cases examined: seven patients exhibited endoleaks (33.3%); two patients exhibited stenosis of a branch of the endograft (9.52%); and one patient exhibited a dissection involving the external iliac artery (4.76%). In the 21 patients assessed, combined use of both methods identified 10 cases of post-EVAR complications. In six of the seven cases of endoleaks (85.71%), use of the methods in combination was capable of identifying the origin of endoleakage. DUS alone failed to identify endoleaks in two cases (28.5%) and identified doubtful findings in another two cases (28.5%), in which diagnostic definition was achieved after employing CEUS. Conclusions CEUS is a technique that is easy to perform and provides additional support for follow-up of infrarenal EVAR.
Collapse
Affiliation(s)
| | | | | | | | | | - Nelson Wolosker
- Hospital Israelita Albert Einstein, Brasil; Universidade de São Paulo, Brasil
| |
Collapse
|
8
|
Chang J, Dumitrache A, Böhling N, Abu-Omar J, Meyer C, Strobel D, Luetkens J, Luu AM, Rockstroh J, Strassburg CP, Trebicka J, Gonzalez-Carmona MA, Marinova M, Praktiknjo M. Alteration of contrast enhanced ultrasound (CEUS) of hepatocellular carcinoma in patients with cirrhosis and transjugular intrahepatic portosystemic shunt (TIPS). Sci Rep 2020; 10:20682. [PMID: 33244180 PMCID: PMC7692482 DOI: 10.1038/s41598-020-77801-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Accepted: 11/17/2020] [Indexed: 02/07/2023] Open
Abstract
Transjugular intrahepatic portosystemic shunt (TIPS) can treat portal hypertensive complications and modifies hepatic hemodynamics. Modification of liver perfusion can alter contrast enhancement dynamics of liver nodules. This study investigated the diagnostic performance of contrast-enhanced ultrasound (CEUS) to diagnose hepatocellular carcinoma (HCC) in cirrhosis with TIPS. In this prospective monocentric observational study, CEUS was used to characterize focal liver lesions in patients at risk for HCC with and without TIPS. Times of arterial phase hyperenhancement (APHE) und washout were quantified. Perfusion-index (PI) and resistance-index (RI) of hepatic artery and portal venous flow parameters were measured via doppler ultrasonography. Diagnostic gold standard was MRI/CT or histology. This study included 49 liver lesions [23 TIPS (11 HCC), 26 no TIPS (15 HCC)]. 26 were diagnosed as HCC by gold standard. Sensitivity and specificity of CEUS to diagnose HCC with and without TIPS were 93.3% and 100% vs. 90.9% and 93.3%, respectively. APHE appeared significantly earlier in patients with TIPS compared to patients without TIPS. TIPS significantly accentuates APHE of HCC in CEUS. CEUS has good diagnostic performance for diagnosis of HCC in patients with TIPS.
Collapse
Affiliation(s)
- Johannes Chang
- Department of Internal Medicine I, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Alexia Dumitrache
- Department of Internal Medicine I, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Nina Böhling
- Department of Internal Medicine I, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Jasmin Abu-Omar
- Department of Internal Medicine I, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Carsten Meyer
- Department of RadioIogy, University Hospital Bonn, Bonn, Germany
| | - Deike Strobel
- Department of Internal Medicine I, University Hospital Erlangen-Nuremberg, Erlangen, Germany
| | - Julian Luetkens
- Department of RadioIogy, University Hospital Bonn, Bonn, Germany
| | - Andreas Minh Luu
- Department of General and Visceral Surgery, St. Josef Hospital, University of Bochum, Bochum, Germany
| | - Jürgen Rockstroh
- Department of Internal Medicine I, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Christian P Strassburg
- Department of Internal Medicine I, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Jonel Trebicka
- Department of Internal Medicine I, University Hospital Frankfurt, Frankfurt, Germany
- European Foundation for the Study of Chronic Liver Failure, Barcelona, Spain
| | - Maria A Gonzalez-Carmona
- Department of Internal Medicine I, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Milka Marinova
- Department of RadioIogy, University Hospital Bonn, Bonn, Germany
| | - Michael Praktiknjo
- Department of Internal Medicine I, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
| |
Collapse
|
9
|
Helfield BL, Yoo K, Liu J, Williams R, Sheeran PS, Goertz DE, Burns PN. Investigating the Accumulation of Submicron Phase-Change Droplets in Tumors. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2861-2870. [PMID: 32732167 DOI: 10.1016/j.ultrasmedbio.2020.06.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 06/24/2020] [Accepted: 06/27/2020] [Indexed: 06/11/2023]
Abstract
Submicron phase-change droplets are an emerging class of ultrasound contrast agent. Compared with microbubbles, their relatively small size and increased stability offer the potential to passively extravasate and accumulate in solid tumors through the enhanced permeability and retention effect. Under exposure to sufficiently powerful ultrasound, these droplets can convert into in situ gas microbubbles and thus be used as an extravascular-specific contrast agent. However, in vivo imaging methods to detect extravasated droplets have yet to be established. Here, we develop an ultrasound imaging pulse sequence within diagnostic safety limits to selectively detect droplet extravasation in tumors. Tumor-bearing mice were injected with submicron perfluorobutane droplets and interrogated with our imaging-vaporization-imaging sequence. By use of a pulse subtraction method, median droplet extravasation signal relative to the total signal within the tumor was estimated to be Etumor=37±5% compared with the kidney Ekidney=-2±8% (p < 0.001). This work contributes toward the advancement of volatile phase-shift droplets as a next-generation ultrasound agent for imaging and therapy.
Collapse
Affiliation(s)
- Brandon L Helfield
- Department of Physics, Concordia University, Montreal, Canada; Department of Biology, Concordia University, Montreal, Canada.
| | - Kimoon Yoo
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Jingjing Liu
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Ross Williams
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Paul S Sheeran
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - David E Goertz
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Peter N Burns
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
10
|
Contrast-Enhanced Ultrasound for Focal Hepatic Lesions: When to Use and How to Differentiate Lesions? Ultrasound Q 2020; 36:224-234. [PMID: 32890325 DOI: 10.1097/ruq.0000000000000475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Contrast-enhanced ultrasound can be used effectively to evaluate focal hepatic lesions and offers unique advantages over computed tomography and magnetic resonance imaging. Serial vascular filling patterns of focal hepatic lesions during arterial, portal, and late phases can provide unique information on lesion characterization and differentiation. Sensitive depiction of arterial hypervascularity and analysis of washout pattern are clues for differentiation of several indeterminate hepatic nodules on conventional ultrasound and computed tomography/magnetic resonance. In this report, we present cases demonstrating clinical applications of contrast-enhanced ultrasound in the diagnosis and management of focal hepatic lesions.
Collapse
|
11
|
|
12
|
Wilson SR, Barr RG. Contrast-Enhanced Ultrasonography of the Abdomen. ADVANCES IN CLINICAL RADIOLOGY 2020; 2:213-233. [DOI: 10.1016/j.yacr.2020.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
13
|
Wu JY, Bai XM, Wang H, Xu Q, Wang S, Wu W, Yan K, Yang W. The Perfusion Features of Recurrent Hepatocellular Carcinoma After Radiofrequency Ablation Using Contrast-Enhanced Ultrasound and Pathological Stemness Evaluation: Compared to Initial Tumors. Front Oncol 2020; 10:1464. [PMID: 32983980 PMCID: PMC7479182 DOI: 10.3389/fonc.2020.01464] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 07/09/2020] [Indexed: 12/14/2022] Open
Abstract
Objective: To investigate the perfusion features of local recurrence in hepatocellular carcinoma (HCC) after radiofrequency ablation (RFA) with contrast-enhanced ultrasound (CEUS) and pathological correlation, as well as to compare with those of initial HCC. Methods: From 2010 to 2018, 42 patients with recurrent HCC after RFA were enrolled in this study. The initial HCC patients included 32 males and 10 females with an average age of 58.2 ± 8.1 years. The CEUS images for initial HCC lesions and local recurrence after RFA were compared. The perfusion features were analyzed, including enhancement time, process, boundary, morphology, washout time, washout degree, feeding vessels, and internal necrosis. H&E staining and CD133/EpCAM staining were performed with biopsy samples for the stemness study. Results: According to CEUS, 59.5% of initial HCC lesions had centripetal enhancement, and 61.9% of recurrent HCC lesions had homogeneous enhancement in the arterial phase (p < 0.001). A total of 73.8% of initial HCC lesions had well-defined margins at the peak, and 81.0% of recurrent HCC lesions had poorly defined margins (p < 0.001). A total of 78.6% of initial HCC lesions had regular morphology at the peak, and 83.3% of recurrent HCC lesions were irregular (p < 0.001). Feeding vessels were more frequently found in initial HCC lesion (71.4%) than in recurrent HCCs (38.1%, p = 0.002). In the late phase, 60% of initial HCCs had marked washout while 83.3% of recurrent HCC lesion had marked washout (p = 0.019). A total of 31.3% of the initial HCC lesions had internal necrosis areas while only 7.1% of recurrent HCC lesions had internal necrosis areas (p = 0.035). In tumors 3-5 cm in size, the washout time of recurrent HCCs was shorter than that of initial HCCs (50.3 ± 13.5 s vs. 75.6 ± 45.8 s, p = 0.013). Pathological staining showed that the tumor stem cell markers (CD133 and EpCAM) were both highly expressed in recurrent samples compared with initial tumor samples (CD133+: 19 vs. 5%, p = 0.002; EpCAM+:15 vs. 6%, p = 0.005). Conclusions: Recurrent HCC after RFA had more homogeneous enhancement with a poorly defined border, marked washout, and fewer less feeding vessels and inner necrosis areas compared to initial HCC. The stemness study also found upregulated stemness in recurrent HCC. These specific features might be related to the aggressive biological behavior of recurrent HCC.
Collapse
Affiliation(s)
- Jin-Yu Wu
- Department of Ultrasound, the First Hospital of Harbin, Harbin, China
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Ultrasound, Peking University Cancer Hospital and Institute, Beijing, China
| | - Xiu-Mei Bai
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Ultrasound, Peking University Cancer Hospital and Institute, Beijing, China
| | - Hong Wang
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Ultrasound, Peking University Cancer Hospital and Institute, Beijing, China
| | - Qian Xu
- Department of Ultrasound, the First Hospital of Harbin, Harbin, China
| | - Song Wang
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Ultrasound, Peking University Cancer Hospital and Institute, Beijing, China
| | - Wei Wu
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Ultrasound, Peking University Cancer Hospital and Institute, Beijing, China
| | - Kun Yan
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Ultrasound, Peking University Cancer Hospital and Institute, Beijing, China
| | - Wei Yang
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Ultrasound, Peking University Cancer Hospital and Institute, Beijing, China
| |
Collapse
|
14
|
Undifferentiated carcinoma of the liver demonstrated by contrast-enhanced ultrasonography. Clin J Gastroenterol 2020; 13:1225-1232. [PMID: 32651870 DOI: 10.1007/s12328-020-01180-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 06/23/2020] [Indexed: 02/08/2023]
Abstract
A 78-year-old man had received interferon therapy and achieved sustained virologic response for chronic hepatitis C 10 years before. He came to our hospital due to liver damage. Abdominal ultrasonography showed a 90-mm mass lesion in the liver. The echoic level was high in the central part and low in the edge of the tumor. Moreover, there was an accumulation of low echoic irregular mass lesions around the hepatic portal region. Cervical ultrasonography also revealed several 15-mm mass lesions on the left clavicle, the imaging character of which was similar to the liver tumor. The liver tumor seemed to be hypovascular on dynamic computed tomography, but contrast-enhanced ultrasonography showed hyperenhancement at the early vascular phase and at maximum intensity projection showed a treelike branch vascular structure that derived from the central part to the margin of the mass. A needle biopsy of the liver tumor and a cervical lymph node resection were performed, which led to the definitive diagnosis of undifferentiated carcinoma of the liver with multiple lymph node metastasis, upon histological analysis. Undifferentiated carcinoma of the liver is extremely rare and contrast-enhanced ultrasonography was the most useful device for evaluating vascular characteristics in this case.
Collapse
|
15
|
Negrão de Figueiredo G, Mueller-Peltzer K, Schwarze V, Marschner C, Zhang L, Rübenthaler J, Siepmann T, Illigens B, Clevert D. Long-term study analysis of contrast-enhanced ultrasound in the diagnosis of focal nodular hyperplasia. Clin Hemorheol Microcirc 2020; 74:441-452. [DOI: 10.3233/ch-190710] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- G. Negrão de Figueiredo
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich – Grosshadern Campus, Munich, Germany
- Division of Health Care Sciences, Center for Clinical Research and Management Education, Dresden International University, Dresden, Germany
| | - K. Mueller-Peltzer
- Division of Health Care Sciences, Center for Clinical Research and Management Education, Dresden International University, Dresden, Germany
| | - V. Schwarze
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich – Grosshadern Campus, Munich, Germany
| | - C. Marschner
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich – Grosshadern Campus, Munich, Germany
| | - L. Zhang
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich – Grosshadern Campus, Munich, Germany
| | - J. Rübenthaler
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich – Grosshadern Campus, Munich, Germany
| | - T. Siepmann
- Division of Health Care Sciences, Center for Clinical Research and Management Education, Dresden International University, Dresden, Germany
| | - B.W. Illigens
- Division of Health Care Sciences, Center for Clinical Research and Management Education, Dresden International University, Dresden, Germany
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - D.A. Clevert
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich – Grosshadern Campus, Munich, Germany
| |
Collapse
|
16
|
Wang DC, Jang HJ, Kim TK. Characterization of Indeterminate Liver Lesions on CT and MRI With Contrast-Enhanced Ultrasound: What Is the Evidence? AJR Am J Roentgenol 2020; 214:1295-1304. [PMID: 32182094 DOI: 10.2214/ajr.19.21498] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
Abstract
OBJECTIVE. CT or MRI is most commonly used for characterizing focal hepatic lesions. However, findings on CT and MRI are occasionally indeterminate. Contrast-enhanced ultrasound (CEUS), with its unique characteristics as a purely intravascular contrast agent and real-time evaluation of enhancement, is a useful next step. The purpose of this article is to review the evidence for performing CEUS in the assessment of indeterminate hepatic lesions seen on CT and MRI. CONCLUSION. CEUS is a useful problem-solving tool in the evaluation of liver lesions that are indeterminate on CT and MRI. Uses include detection of arterial phase hyperenhancement; differentiation between hepatocellular carcinoma and intrahepatic cholangiocarcinoma; determination of benign versus malignant tumor thrombus, benign versus neoplastic cystic hepatic lesions, and hepatocellular adenoma versus focal nodular hyperplasia; and monitoring for recurrence in postablative therapies. CEUS can help establish a confident diagnosis and determine the need for further invasive diagnosis or treatment.
Collapse
Affiliation(s)
- David C Wang
- Department of Medical Imaging, Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, University of Toronto, 585 University Ave, Toronto, ON M5G 2N2, Canada
| | - Hyun-Jung Jang
- Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, University of Toronto, 585 University Ave, Toronto, ON M5G 2N2, Canada
| | - Tae Kyoung Kim
- Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, University of Toronto, 585 University Ave, Toronto, ON M5G 2N2, Canada
| |
Collapse
|
17
|
Wilson SR, Burns PN, Kono Y. Contrast-Enhanced Ultrasound of Focal Liver Masses: A Success Story. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1059-1070. [PMID: 32059917 DOI: 10.1016/j.ultrasmedbio.2019.12.021] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Revised: 12/17/2019] [Accepted: 12/19/2019] [Indexed: 06/10/2023]
Abstract
The epidemic of increasing fatty liver disease and liver cancer worldwide, and especially in Western society, has given new importance to non-invasive liver imaging. Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents provides unique advantages over computed tomography (CT) and magnetic resonance imaging (MRI), the currently established methods. CEUS provides determination of malignancy and allows excellent differential diagnosis of a focal liver mass, based on arterial phase enhancement patterns and assessment of the timing and intensity of washout. Today, increased use of CEUS has provided safe and rapid diagnosis of incidentally detected liver masses, improved multidisciplinary management of nodules in a cirrhotic liver, facilitated ablative therapy for liver tumors and allowed diagnosis of hepatocellular carcinoma without biopsy. Benefits of CEUS include the dynamic real-time depiction of tumor perfusion and the fact that it is a purely intravascular agent, accurately reflecting tumoral and inflammatory blood flow. CEUS has many similarities to contrast-enhanced CT and MRI but also unique differences, which are described. The integration of CEUS into a multimodality imaging setting optimizes patient care.
Collapse
Affiliation(s)
- Stephanie R Wilson
- Department of Radiology, and Division of Gastroenterology, Department of Medicine, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada.
| | - Peter N Burns
- Department of Medical Biophysics, University of Toronto, Imaging Research, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Yuko Kono
- Department of Medicine, Division of Gastroenterology and Hepatology, University of California San Diego, San Diego, CA
| |
Collapse
|
18
|
Song X, Wang S, Zhao C, Zhang W, Wang G, Jia S. Visual method for evaluating liver function: targeted in vivo fluorescence imaging of the asialoglycoprotein receptor. BIOMEDICAL OPTICS EXPRESS 2019; 10:5015-5024. [PMID: 31646026 PMCID: PMC6788595 DOI: 10.1364/boe.10.005015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 08/28/2019] [Accepted: 09/01/2019] [Indexed: 06/10/2023]
Abstract
The visual evaluation of liver function (LF) has always been a hot topic in research on liver diseases. In vivo fluorescence imaging (IVFI) of the Cy5.5-galactosylated polylysine (Cy5.5-GP) probe targeting asialoglycoprotein receptor (ASGPR), for evaluating LF in chronic alcoholic liver injury (cALI) mice was investigated in this study. The decrease of fluorescence signals in the livers showed a biological relationship with the liver ASGPR expression, histology, and serum marker levels of LF in cALI mice. The targeted IVFI of ASGPR as a novel method can intuitively and noninvasively display the characteristics of liver's ASGPR level to provide a reference for evaluating LF.
Collapse
Affiliation(s)
- Xiaojing Song
- Department of Biomedical Engineering, Institute of Acupuncture & Moxibustion, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Shuyou Wang
- Department of Biomedical Engineering, Institute of Acupuncture & Moxibustion, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Chong Zhao
- Beijing Hapten and Protein Biomedical Institute, Beijing, 102206, China
| | - Weibo Zhang
- Department of Biomedical Engineering, Institute of Acupuncture & Moxibustion, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Guangjun Wang
- Department of Biomedical Engineering, Institute of Acupuncture & Moxibustion, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Shuyong Jia
- Department of Biomedical Engineering, Institute of Acupuncture & Moxibustion, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| |
Collapse
|
19
|
Lange A, Muniraj T, Aslanian HR. Endoscopic Ultrasound for the Diagnosis and Staging of Liver Tumors. Gastrointest Endosc Clin N Am 2019; 29:339-350. [PMID: 30846157 DOI: 10.1016/j.giec.2018.12.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Endoscopic ultrasound examination may provide complementary information to cross-sectional imaging in lesions of the liver, portal vein, and surrounding lymph nodes. With fine needle aspiration, endoscopic ultrasound examination is a powerful tool for the diagnosis of focal liver lesions and has usefulness in the evaluation of indeterminate liver lesions. Endoscopic ultrasound examination may influence hepatocellular cancer staging and Endoscopic ultrasound examination with fine needle aspiration of locoregional nodes and portal vein thromboses changes management. Contrast-enhanced endoscopic ultrasound examination and endoscopic ultrasound examination elastography are likely to expand the usefulness of endoscopic ultrasound examination in evaluating liver malignancy with technologic improvements.
Collapse
Affiliation(s)
- Andrew Lange
- Department of Internal Medicine, Yale University School of Medicine, Yale Primary Care Center, 789 Howard Avenue, New Haven, CT 06511, USA
| | - Thiruvengadam Muniraj
- Section of Digestive Diseases, Laboratory for Medicine and Pediatrics, Yale University School of Medicine, 15 York Street, New Haven, CT 06510, USA
| | - Harry R Aslanian
- Section of Digestive Diseases, Yale University School of Medicine, PO Box 208056, 333 Cedar Street, New Haven, CT 06520, USA.
| |
Collapse
|
20
|
Yang HK, Burns PN, Jang HJ, Kono Y, Khalili K, Wilson SR, Kim TK. Contrast-enhanced ultrasound approach to the diagnosis of focal liver lesions: the importance of washout. Ultrasonography 2019; 38:289-301. [PMID: 31311068 PMCID: PMC6769186 DOI: 10.14366/usg.19006] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 03/17/2019] [Indexed: 12/12/2022] Open
Abstract
Contrast-enhanced ultrasound (CEUS) is a powerful technique for differentiating focal liver lesions (FLLs) without the risks of potential nephrotoxicity or ionizing radiation. In the diagnostic algorithm for FLLs on CEUS, washout is an important feature, as its presence is highly suggestive of malignancy and its characteristics are useful in distinguishing hepatocellular from nonhepatocellular malignancies. Interpreting washout on CEUS requires an understanding that microbubble contrast agents are strictly intravascular, unlike computed tomography or magnetic resonance imaging contrast agents. This review explains the definition and types of washout on CEUS in accordance with the 2017 version of the CEUS Liver Imaging Reporting and Data System and presents their applications to differential diagnosis with illustrative examples. Additionally, we propose potential mechanisms of rapid washout and describe the washout phenomenon in benign entities.
Collapse
Affiliation(s)
- Hyun Kyung Yang
- Joint Department of Medical Imaging, University of Toronto, Toronto, Canada
| | - Peter N Burns
- Department of Medical Biophysics, Sunnybrook Research Institute, University of Toronto, Toronto, Canada
| | - Hyun-Jung Jang
- Joint Department of Medical Imaging, University of Toronto, Toronto, Canada
| | - Yuko Kono
- Departments of Medicine and Radiology, University of California, San Diego, CA, USA
| | - Korosh Khalili
- Joint Department of Medical Imaging, University of Toronto, Toronto, Canada
| | - Stephanie R Wilson
- Diagnostic Imaging, Department of Radiology, University of Calgary, Calgary, Canada
| | - Tae Kyoung Kim
- Joint Department of Medical Imaging, University of Toronto, Toronto, Canada
| |
Collapse
|
21
|
Kuo M, Mo L. The application of contrast‐enhanced ultrasound for the characterization of hepatic tumors: An assessment focusing on hepatocellular carcinoma. ADVANCES IN DIGESTIVE MEDICINE 2019. [DOI: 10.1002/aid2.13103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Ming‐Jeng Kuo
- Department of HepatogastroenterologyTainan Municipal Hospital Tainan Taiwan
- Department of Tourism and ManagementChia Nan University of Pharmacy and Science Tainan Taiwan
| | - Lein‐Ray Mo
- Department of HepatogastroenterologyTainan Municipal Hospital Tainan Taiwan
| |
Collapse
|
22
|
Cracking pattern of tissue slices induced by external extension provides useful diagnostic information. Sci Rep 2018; 8:12167. [PMID: 30111854 PMCID: PMC6093865 DOI: 10.1038/s41598-018-30662-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Accepted: 08/01/2018] [Indexed: 11/17/2022] Open
Abstract
Although biopsy is one of the most important methods for diagnosis in diseases, there is ambiguity based on the information obtained from the visual inspection of tissue slices. Here, we studied the effect of external extension on tissue slices from mouse liver with different stages of disease: Healthy normal state, Simple steatosis, Non-alcoholic steatohepatitis and Hepatocellular carcinoma. We found that the cracking pattern of a tissue slice caused by extension can provide useful information for distinguishing among the disease states. Interestingly, slices with Hepatocellular carcinoma showed a fine roughening on the cracking pattern with a characteristic length of the size of cells, which is much different than the cracking pattern for slices with non-cancerous steatosis, for which the cracks were relatively straight. The significant difference in the cracking pattern depending on the disease state is attributable to a difference in the strength of cell-cell adhesion, which would be very weak under carcinosis. As it is well known that the manner of cell-cell adhesion neatly concerns with the symptoms in many diseases, it may be promising to apply the proposed methodology to the diagnosis of other diseases.
Collapse
|
23
|
Zarzour JG, Porter KK, Tchelepi H, Robbin ML. Contrast-enhanced ultrasound of benign liver lesions. Abdom Radiol (NY) 2018; 43:848-860. [PMID: 29167944 DOI: 10.1007/s00261-017-1402-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Liver lesions are often incidentally detected on ultrasound examination and may be incompletely characterized, requiring further imaging. Contrast-enhanced ultrasound (CEUS) was recently approved by the Food and Drug Administration in the United States for liver lesion characterization. CEUS has the ability to characterize focal liver lesions and has been shown to be superior to color Doppler and power Doppler ultrasound in the detection of tumor vascularity. Differentiating benign from malignant liver lesions is essential to characterizing liver lesions. The CEUS imaging characteristics of benign liver lesions are reviewed, including hepatic cysts, hemangiomas, focal fat, focal nodular hyperplasia, hepatocellular adenomas, abscesses, and traumatic lesions.
Collapse
Affiliation(s)
- Jessica G Zarzour
- Department of Radiology, University of Alabama at Birmingham, 619 19th Street South, JTN 338, Birmingham, AL, 35294, USA.
| | - Kristin K Porter
- Department of Radiology, University of Alabama at Birmingham, 619 19th Street South, JTN 338, Birmingham, AL, 35294, USA
| | - Hisham Tchelepi
- Department of Radiology, University of Southern California, Los Angeles, USA
| | - Michelle L Robbin
- Department of Radiology, University of Alabama at Birmingham, 619 19th Street South, JTN 338, Birmingham, AL, 35294, USA
| |
Collapse
|
24
|
Detsky JS, Milot L, Ko YJ, Munoz-Schuffenegger P, Chu W, Czarnota G, Chung HT. Perfusion imaging of colorectal liver metastases treated with bevacizumab and stereotactic body radiotherapy. Phys Imaging Radiat Oncol 2018; 5:9-12. [PMID: 33458362 PMCID: PMC7807608 DOI: 10.1016/j.phro.2018.01.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Revised: 01/02/2018] [Accepted: 01/02/2018] [Indexed: 01/18/2023] Open
Abstract
Stereotactic body radiotherapy (SBRT) and bevacizumab are used in the treatment of colorectal liver metastases. This study prospectively evaluated changes in perfusion of liver metastases in seven patients treated with both bevacizumab and SBRT. Functional imaging using dynamic contrast-enhanced CT perfusion and contrast-enhanced ultrasound were performed at baseline, after bevacizumab, and after SBRT. After bevacizumab, a significant decrease was found in permeability (−28%, p < .05) and blood volume (−47%, p < .05), while SBRT led to a significant reduction in permeability (−22%, p < .05) and blood flow (−37%, p < .05). This study demonstrates that changes in perfusion can be detected after bevacizumab and SBRT.
Collapse
Affiliation(s)
- Jay S Detsky
- Department of Radiation Oncology, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Laurent Milot
- Department of Medical Imaging, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | - Yoo-Joung Ko
- Department of Medical Oncology, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Medical Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Pablo Munoz-Schuffenegger
- Department of Radiation Oncology, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - William Chu
- Department of Radiation Oncology, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Gregory Czarnota
- Department of Radiation Oncology, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Hans T Chung
- Department of Radiation Oncology, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
25
|
Bakas S, Makris D, Hunter GJA, Fang C, Sidhu PS, Chatzimichail K. Automatic Identification of the Optimal Reference Frame for Segmentation and Quantification of Focal Liver Lesions in Contrast-Enhanced Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2438-2451. [PMID: 28705557 DOI: 10.1016/j.ultrasmedbio.2017.06.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2017] [Revised: 05/17/2017] [Accepted: 06/02/2017] [Indexed: 06/07/2023]
Abstract
Post-examination interpretation of contrast-enhanced ultrasound (CEUS) cineloops of focal liver lesions (FLLs) requires offline manual assessment by experienced radiologists, which is time-consuming and generates subjective results. Such assessment usually starts by manually identifying a reference frame, where FLL and healthy parenchyma are well-distinguished. This study proposes an automatic computational method to objectively identify the optimal reference frame for distinguishing and hence delineating an FLL, by statistically analyzing the temporal intensity variation across the spatially discretized ultrasonographic image. Level of confidence and clinical value of the proposed method were quantitatively evaluated on retrospective multi-institutional data (n = 64) and compared with expert interpretations. Results support the proposed method for facilitating easier, quicker and reproducible assessment of FLLs, further increasing the radiologists' confidence in diagnostic decisions. Finally, our method yields a useful training tool for radiologists, widening CEUS use in non-specialist centers, potentially leading to reduced turnaround times and lower patient anxiety and healthcare costs.
Collapse
Affiliation(s)
- Spyridon Bakas
- Digital Information Research Centre (DIRC), School of Computer Science & Mathematics, Faculty of Science, Engineering and Computing (SEC), Kingston University, Penrhyn Road, Kingston-Upon-Thames, London, United Kingdom; Center for Biomedical Image Computing and Analytics (CBICA), Perelman School of Medicine, University of Pennsylvania, Richards Medical Research Laboratories, Philadelphia, PA, USA.
| | - Dimitrios Makris
- Digital Information Research Centre (DIRC), School of Computer Science & Mathematics, Faculty of Science, Engineering and Computing (SEC), Kingston University, Penrhyn Road, Kingston-Upon-Thames, London, United Kingdom
| | - Gordon J A Hunter
- Digital Information Research Centre (DIRC), School of Computer Science & Mathematics, Faculty of Science, Engineering and Computing (SEC), Kingston University, Penrhyn Road, Kingston-Upon-Thames, London, United Kingdom
| | - Cheng Fang
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Paul S Sidhu
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Katerina Chatzimichail
- Radiology & Imaging Research Centre, Evgenidion Hospital, National and Kapodistrian University, Athens, Greece
| |
Collapse
|
26
|
Burrowes DP, Medellin A, Harris AC, Milot L, Wilson SR. Contrast-enhanced US Approach to the Diagnosis of Focal Liver Masses. Radiographics 2017; 37:1388-1400. [DOI: 10.1148/rg.2017170034] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- David P. Burrowes
- From the Department of Radiology, University of Calgary, Calgary, Alberta, Canada (D.P.B., A.M., S.R.W.); Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada (A.C.H.); and Department of Radiology, University of Toronto, Toronto, Ontario, Canada (L.M.). Recipient of a Magna Cum Laude award for an education exhibit at the 2016 RSNA Annual Meeting
| | - Alexandra Medellin
- From the Department of Radiology, University of Calgary, Calgary, Alberta, Canada (D.P.B., A.M., S.R.W.); Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada (A.C.H.); and Department of Radiology, University of Toronto, Toronto, Ontario, Canada (L.M.). Recipient of a Magna Cum Laude award for an education exhibit at the 2016 RSNA Annual Meeting
| | - Allison C. Harris
- From the Department of Radiology, University of Calgary, Calgary, Alberta, Canada (D.P.B., A.M., S.R.W.); Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada (A.C.H.); and Department of Radiology, University of Toronto, Toronto, Ontario, Canada (L.M.). Recipient of a Magna Cum Laude award for an education exhibit at the 2016 RSNA Annual Meeting
| | - Laurent Milot
- From the Department of Radiology, University of Calgary, Calgary, Alberta, Canada (D.P.B., A.M., S.R.W.); Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada (A.C.H.); and Department of Radiology, University of Toronto, Toronto, Ontario, Canada (L.M.). Recipient of a Magna Cum Laude award for an education exhibit at the 2016 RSNA Annual Meeting
| | - Stephanie R. Wilson
- From the Department of Radiology, University of Calgary, Calgary, Alberta, Canada (D.P.B., A.M., S.R.W.); Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada (A.C.H.); and Department of Radiology, University of Toronto, Toronto, Ontario, Canada (L.M.). Recipient of a Magna Cum Laude award for an education exhibit at the 2016 RSNA Annual Meeting
| |
Collapse
|
27
|
Kondo S, Takagi K, Nishida M, Iwai T, Kudo Y, Ogawa K, Kamiyama T, Shibuya H, Kahata K, Shimizu C. Computer-Aided Diagnosis of Focal Liver Lesions Using Contrast-Enhanced Ultrasonography With Perflubutane Microbubbles. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:1427-1437. [PMID: 28141517 DOI: 10.1109/tmi.2017.2659734] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
This paper proposes an automatic classification method based on machine learning in contrast-enhanced ultrasonography (CEUS) of focal liver lesions using the contrast agent Sonazoid. This method yields spatial and temporal features in the arterial phase, portal phase, and post-vascular phase, as well as max-hold images. The lesions are classified as benign or malignant and again as benign, hepatocellular carcinoma (HCC), or metastatic liver tumor using support vector machines (SVM) with a combination of selected optimal features. Experimental results using 98 subjects indicated that the benign and malignant classification has 94.0% sensitivity, 87.1% specificity, and 91.8% accuracy, and the accuracy of the benign, HCC, and metastatic liver tumor classifications are 84.4%, 87.7%, and 85.7%, respectively. The selected features in the SVM indicate that combining features from the three phases are important for classifying FLLs, especially, for the benign and malignant classifications. The experimental results are consistent with CEUS guidelines for diagnosing FLLs. This research can be considered to be a validation study, that confirms the importance of using features from these phases of the examination in a quantitative manner. In addition, the experimental results indicate that for the benign and malignant classifications, the specificity without the post-vascular phase features is significantly lower than the specificity with the post-vascular phase features. We also conducted an experiment on the operator dependency of setting regions of interest and observed that the intra-operator and inter-operator kappa coefficients were 0.45 and 0.77, respectively.
Collapse
|
28
|
Barr RG. How to Develop a Contrast-Enhanced Ultrasound Program. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2017; 36:1225-1240. [PMID: 28151552 DOI: 10.7863/ultra.16.09045] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Accepted: 11/08/2016] [Indexed: 06/06/2023]
Abstract
With the recent Food and Drug Administration approval of Lumason (sulfur hexafluoride lipid-type A microsphere, Bracco Diagnostics Inc, Monroe Township, NJ) for contrast-enhanced ultrasound (CEUS) to characterize focal liver lesions in both adult and pediatric patients, widespread use of CEUS is expected in the United States. This paper provides guidance in setting up a CEUS program, and reviews the practical details that will need to be instituted in a standard ultrasound department to provide both safe and efficient use of CEUS. A review of the indications, contraindications, adverse events, instructions for performing the exam, and image interpretation are discussed.
Collapse
Affiliation(s)
- Richard G Barr
- Northeast Ohio Medical University, Rootstown, Ohio USA
- Radiology Consultants, Youngstown, Ohio, USA
| |
Collapse
|
29
|
Jo PC, Jang HJ, Burns PN, Burak KW, Kim TK, Wilson SR. Integration of Contrast-enhanced US into a Multimodality Approach to Imaging of Nodules in a Cirrhotic Liver: How I Do It. Radiology 2017; 282:317-331. [PMID: 28099108 DOI: 10.1148/radiol.2016151732] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Accurate characterization of cirrhotic nodules and early diagnosis of hepatocellular carcinoma (HCC) are of vital importance. Currently, computed tomography (CT) and magnetic resonance (MR) imaging are standard modalities for the investigation of new nodules found at surveillance ultrasonography (US). This article describes the successful integration of contrast material-enhanced US into a multimodality approach for diagnosis of HCC and its benefits in this population. The application of contrast-enhanced US immediately following surveillance US allows for prompt dynamic contrast-enhanced evaluation, removing the need for further imaging of benign lesions. Contrast-enhanced US also provides dynamic real-time assessment of tumor vascularity so that contrast enhancement can be identified regardless of its timing or duration, allowing for detection of arterial hypervascularity and portal venous washout. The purely intravascular nature of US contrast agents is valuable as the rapid washout of nonhepatocyte malignancies is highly contributory to their differentiation from HCC. The authors believe contrast-enhanced US provides complementary information to CT and MR imaging in the characterization of nodules in high-risk patients. © RSNA, 2017 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Patricia C Jo
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Hyun-Jung Jang
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Peter N Burns
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Kelly W Burak
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Tae Kyoung Kim
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Stephanie R Wilson
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| |
Collapse
|
30
|
Agaeva ZA, Avhadov TS, Gorbov LV, Karanadze EN. The Practice of Using Contrast Sonography for the Differential Diagnosis of Liver Neoplasms. ACTA ACUST UNITED AC 2017. [DOI: 10.24835/1607-0763-2017-1-13-19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Purpose: to improve the differential diagnosis of benign liver rumors and the liver metastasis of colorectal cancer with the ultrasound using contrast sonography.Materials and methods.There were evaluated 92 patients with liver neoplasms (44 (47.8%) women and 48 (52.2%) men) age 41 to 83, with a mean age of 62.8 ± 2.64. Ultrasound exam was carried out in three stages: I stage – liver ultrasound in B-mode, II stage – ultrasound in B-mode with addition of color Doppler imaging and power Doppler scanning, III stage – contrast liver sonography employing the contrast agent SonoVue (Bracco Imaging SpA, Milan, Italy). According to the results of the examination the patients were either surgically treated if there were indications, or the nature of the neoplasm was verified via the needle biopsy. Thus the patients formed two groups: I group (n = 35 (38.0%) – patients with benign liver neoplasms: cavernous hemangiomas – 17, hepatocellular adenomas – 3, focal modular hyperplasia of the liver – 5; II group (n = 57 (62.0%) – patients with metastasis of colorectal cancer.Results.With the use of the ultrasound in B-mode with addition of color Doppler imaging and power Doppler scanning in patients from group I (n = 35) with benign tumors of the liver – bilobar involvement in 2 cases, right lobe involvement in 28 cases, left lobe involvement in 5 cases. There were found both solitary (in 33 cases) and multiple (in 2 cases) neoplasms ranging from 2.5– 4.5 cm to conglomerates of 8–17 cm in diameter. In group II (n = 57), in patients with colorectal cancer metastasis who had an ultrasound examination in B-mode with addition of color Doppler imaging and power Doppler scanning, bilobar metastatic (91.2%) involvement of the liver prevailed over the monolobar, notably right lobe (84.21%) involvement was more frequent. Multiple metastasis were encountered more often (89.5%) then solitary. At the moment of metastatic liver disease discovery the size of the tumor nodules was over 5 cm in diameter in 33 (57.8%) patients. According to the results of contrast sonography in patients of group I (n = 35) with benign tumors of the liver, there was detected a prolonged enhancement of the neoplasm in the arterial, portal and delayed phases of enhancement. In patients of group II (n = 57) with metastasis of colorectal cancer to the liver, in the end of arterial phase there was noted a “washing out” of the contrast agent by 16th second – in 36 (63.1%) of the patients, by 23th se cond – in 17 (29.8%) and by the 26th second – in 4 (7.0%) of the patients. In portal and delayed phase of the enhancement all of the group II patients (100%) at the site of the metastasis there were located anechogenic round foci.Conclusions. 1. Complex 3-stage ultrasound examination (B-mode, color Doppler imaging and power Doppler scanning, contrast sonography) of the liver neoplasms allows to get a more detailed information and differentiate benign and metastatic disease of the liver; 2. During contrast sonography the benign liver tumors “keep” the contrast gent during the arterial, portal and delayed enhancement phases, but with metastasis in liver the contrast agent gets “washed out” already in the arterial phase of enhancement.
Collapse
|
31
|
Malone CD, Mattrey RF, Fetzer DT. Contrast-Enhanced Ultrasound (CEUS) for the Diagnosis and Management of Hepatocellular Carcinoma: Current Status and Future Trends. ACTA ACUST UNITED AC 2016. [DOI: 10.1007/s11901-016-0324-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
32
|
Ultrasonography for resuscitative endovascular balloon occlusion of the aorta: A practical leap forward using microbubble contrast agent. J Trauma Acute Care Surg 2016; 81:616-7. [PMID: 27257695 DOI: 10.1097/ta.0000000000001130] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
33
|
Chaubal N, Joshi M, Bam A, Chaubal R. Contrast-Enhanced Ultrasound of Focal Liver Lesions. Semin Roentgenol 2016; 51:334-357. [PMID: 27743569 DOI: 10.1053/j.ro.2016.05.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Nitin Chaubal
- Thane Ultrasound Center, Thane (W), MS, India; Jaslok Hospital & Research Centre, Mumbai.
| | - Mukund Joshi
- Thane Ultrasound Center, Thane (W), MS, India; Jaslok Hospital & Research Centre, Mumbai
| | - Anupam Bam
- Thane Ultrasound Center, Thane (W), MS, India
| | | |
Collapse
|
34
|
Preoperative detection of hepatic metastases from colorectal cancer: Prospective comparison of contrast-enhanced ultrasound and multidetector-row computed tomography (MDCT). Diagn Interv Imaging 2016; 97:851-5. [PMID: 27132590 DOI: 10.1016/j.diii.2015.11.017] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 10/30/2015] [Accepted: 11/05/2015] [Indexed: 12/19/2022]
Abstract
PURPOSE The goal of this study was to prospectively compare the sensitivity of contrast-enhanced ultrasound (CEUS) with that of multiphase multidetector-row computed tomography (MDCT) in the preoperative detection of hepatic metastases. MATERIALS AND METHOD Forty-eight patients, with a mean age of 62years old (range: 43-85years) were prospectively included. All patients underwent CEUS following intravenous administration of 2.4mL of an ultrasound contrast agent (Sonovue(®), Bracco, Milan, Italy) and multiphase MDCT. Intraoperative ultrasound examination (IOUS) was used as the standard of reference. RESULTS A total of 158 liver metastases were identified by IOUS, 127 by preoperative MDCT (sensitivity; 80.4%) and 102 by CEUS (sensitivity, 64.5%). The 15.9% difference in sensitivity between CEUS and MDCT was statistically significant (P=0.002). There was a disagreement between IOUS and CEUS in 23 patients (47%) and in 13 patients (27%) between IOUS and MDCT. MDCT identified one or more additional metastases in 10 patients (20%) resulting in a change in the surgical strategy. CONCLUSION Based on an unselected patient cohort and using multiphase MDCT, CEUS is significantly inferior to MDCT for the preoperative detection of hepatic metastases of colorectal cancer.
Collapse
|
35
|
Jang HJ, Kim TK, Burns PN, Wilson SR. CEUS: An essential component in a multimodality approach to small nodules in patients at high-risk for hepatocellular carcinoma. Eur J Radiol 2015; 84:1623-35. [DOI: 10.1016/j.ejrad.2015.05.020] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Accepted: 05/11/2015] [Indexed: 02/07/2023]
|
36
|
Current Status of Imaging to Evaluate Liver Metastases From Colorectal Cancer. CURRENT COLORECTAL CANCER REPORTS 2015. [DOI: 10.1007/s11888-015-0272-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
37
|
Obaro AE, Ryan SM. Benign liver lesions: grey-scale and contrast-enhanced ultrasound appearances. ULTRASOUND : JOURNAL OF THE BRITISH MEDICAL ULTRASOUND SOCIETY 2015; 23:116-25. [PMID: 27433246 DOI: 10.1177/1742271x15575805] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Ultrasound is often the first point of detection of liver lesions, with up to 75% of liver lesions detected at ultrasound having benign histology. In 2012, NICE issued recommendations that ultrasound contrast be used for the evaluation of incidentally discovered liver lesions. This has been demonstrated to provide a rapid and cost-effective evaluation for incidental liver lesions, in many cases precluding the need for further CT or MRI scans. The aim of this review is to demonstrate the ultrasound features of benign liver lesions, and to demonstrate their further characterisation with contrast ultrasound.
Collapse
Affiliation(s)
- A E Obaro
- Department of Radiology, King's College Hospital NHS Foundation Trust, Denmark Hill, London, UK
| | - S M Ryan
- Department of Radiology, King's College Hospital NHS Foundation Trust, Denmark Hill, London, UK
| |
Collapse
|
38
|
Riccabona M. Why consider contrast-enhanced ultrasound (ce-US) in children?: Editorial comment on: M.M. Woźniak, A. Pawelec, A.P. Wieczorek, M.M. Zajączkowska, H. Borzęcka and P. Nachulewicz 2D/3D/4D contrast-enhanced voiding urosnography in the diagnosis and monitoring of treatment of vesicoureteral reflux in children - can it replace voiding cystourethrography? J Ultrason 2014; 14:447-53. [PMID: 26673607 PMCID: PMC4579718 DOI: 10.15557/jou.2014.0048] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Revised: 09/15/2014] [Accepted: 09/19/2014] [Indexed: 12/27/2022] Open
Affiliation(s)
- Michael Riccabona
- Department of Radiology, Division of Pediatric Radiology, University Hospital LKH Graz, Graz, Austria
| |
Collapse
|
39
|
Joshi P, George RA, Tyagi AK, Sinha A. Efficacy of contrast enhanced grey scale ultrasound in characterisation of hepatic focal lesions: A pilot study. Med J Armed Forces India 2014; 70:230-6. [PMID: 25378775 DOI: 10.1016/j.mjafi.2014.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2013] [Accepted: 05/25/2014] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Contrast enhanced ultrasound (CEUS) has recently gained widespread acceptance as an adjunct to conventional grey scale ultrasound. The present pilot study was undertaken to evaluate the efficacy of this technique in characterisation of hepatic focal lesions. METHODS Adult patients who had at least one focal liver lesion underwent ultrasound evaluation in regular and contrast mode before and after intravenous administration of sulphur hexafluoride. The diagnoses were confirmed by comparison with a reference standard (multidetector CT), response to treatment or pathological correlation. RESULTS The rate of correct diagnosis for unenhanced ultrasound was 54%, CEUS was 72% and multidetector CT (MDCT) was 92%. A comparison of unenhanced ultrasound versus CEUS using the McNemar test yielded a p value of 0.0704 (>0.05). However, comparison of CEUS versus MDCT using the McNemar test yielded a p value of 0.0265 (<0.05). Additionally, comparison of unenhanced ultrasound versus MDCT using the McNemar test yielded a p value of <0.0001. CONCLUSION CEUS increases diagnostic efficacy over unenhanced ultrasound but does not have any significant advantages over MDCT. Currently it may be used as a problem solving tool in atypical haemangiomas, echogenic focal liver lesions, contrast sensitivity and to avoid multiple studies utilising ionising radiation.
Collapse
Affiliation(s)
- P Joshi
- Classified Specialist (Radiodiagnosis), INHS Asvini, Colaba, Mumbai 400005, India
| | - R A George
- Senior Advisor (Radiodiagnosis), Command Hospital (Air Force), Bangalore 560007, India
| | - A K Tyagi
- Senior Advisor (Surgery and Surgical Oncology), Army Hospital (R&R), Delhi Cantt, India
| | - Anamika Sinha
- Classified Specialist (Pathology), Command Hospital (Northern Command), C/o 56 APO, India
| |
Collapse
|
40
|
Izamis ML, Efstathiades A, Keravnou C, Leen EL, Averkiou MA. Dynamic contrast-enhanced ultrasound of slaughterhouse porcine livers in machine perfusion. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2217-2230. [PMID: 25023101 DOI: 10.1016/j.ultrasmedbio.2014.03.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Revised: 03/28/2014] [Accepted: 03/31/2014] [Indexed: 06/03/2023]
Abstract
The aim of this study was to enable investigations into novel imaging and surgical techniques by developing a readily accessible, versatile liver machine perfusion system. Slaughterhouse pig livers were used, and dynamic contrast-enhanced ultrasound was introduced to optimize the procurement process and provide real-time perfusion monitoring. The system comprised a single pump, oxygenator, bubble trap and two flowmeters for pressure-controlled perfusion of the vessels using an off-the-shelf perfusate at room temperature. Successful livers exhibited homogeneous perfusion in both the portal vein and hepatic artery with dynamic contrast-enhanced ultrasound, which correlated with stable oxygen uptake, bile production and hepatic resistance and normal histology at the end of 3 h of perfusion. Dynamic contrast-enhanced ultrasound revealed perfusion abnormalities invisible to the naked eye, thereby providing context to the otherwise systemic biochemical/hemodynamic measurements and focal biopsy findings. The model developed here is a simple, cost-effective approach for stable ex vivo whole-organ machine perfusion.
Collapse
Affiliation(s)
- Maria-Louisa Izamis
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus
| | | | - Christina Keravnou
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus
| | - Edward L Leen
- Department of Medicine, Imperial College, London, United Kingdom
| | - Michalakis A Averkiou
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus.
| |
Collapse
|
41
|
The Correlation of Contrast-Enhanced Ultrasound and MRI Perfusion Quantitative Analysis in Rabbit VX2 Liver Cancer. Cell Biochem Biophys 2014; 70:1859-67. [DOI: 10.1007/s12013-014-0143-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
42
|
Izamis ML, Efstathiades A, Keravnou C, Georgiadou S, Martins PN, Averkiou MA. Effects of air embolism size and location on porcine hepatic microcirculation in machine perfusion. Liver Transpl 2014; 20:601-11. [PMID: 24478135 DOI: 10.1002/lt.23838] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2013] [Accepted: 01/05/2014] [Indexed: 02/07/2023]
Abstract
The handling of donor organs frequently introduces air into the microvasculature, but little is known about the extent of the damage caused as a function of the embolism size and distribution. Here we introduced embolisms of different sizes into the portal vein, the hepatic artery, or both during the flushing stage of porcine liver procurement. The outcomes were evaluated during 3 hours of machine perfusion and were compared to the outcomes of livers with no embolisms. Dynamic contrast-enhanced ultrasound (DCEUS) was used to assess the perfusion quality, and it demonstrated that embolisms tended to flow mostly into the left lobe, occasionally into the right lobe, and rarely into the caudate lobe. Major embolisms could disrupt the flow entirely, whereas minor embolisms resulted in reduced or heterogeneous flow. Embolisms occasionally migrated to different regions of the same lobe and, regardless of their size, caused a general deterioration in the flow over time. Histological damage resulted primarily when both vessels of the liver were compromised, whereas bile production was diminished in livers that had arterial embolisms. Air embolisms produced a dose-dependent increase in vascular resistance and a decline in oxygen consumption. This is the first article to quantify the impact of air embolisms on microcirculation in an experimental model, and it demonstrates that air embolisms have the capacity to degrade the integrity of donor organs. The extent of organ damage is strongly dependent on the size and distribution of air embolisms. The diagnosis of embolism severity can be safely and easily made with DCEUS.
Collapse
Affiliation(s)
- Maria-Louisa Izamis
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus
| | | | | | | | | | | |
Collapse
|
43
|
Role of contrast enhanced ultrasound in characterization of focal liver lesions. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2014. [DOI: 10.1016/j.ejrnm.2013.11.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
|
44
|
Kamaya A, Machtaler S, Safari Sanjani S, Nikoozadeh A, Graham Sommer F, Pierre Khuri-Yakub BT, Willmann JK, Desser TS. New technologies in clinical ultrasound. Semin Roentgenol 2014; 48:214-23. [PMID: 23796372 DOI: 10.1053/j.ro.2013.03.009] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- Aya Kamaya
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA.
| | | | | | | | | | | | | | | |
Collapse
|
45
|
Won SY, Singh N, Lim BG, Stella D, Gibson R. Hepatic contrast-enhanced ultrasound: impact of its introduction in the Australian context. J Med Imaging Radiat Oncol 2014; 58:38-45. [PMID: 24529054 DOI: 10.1111/1754-9485.12093] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2013] [Accepted: 06/03/2013] [Indexed: 12/19/2022]
Abstract
INTRODUCTION Contrast-enhanced ultrasound (CEUS) is a relatively new imaging modality in Australia. We discuss our early experience with CEUS at Royal Melbourne Hospital in assessment of focal liver lesions and its clinical impact. METHOD Radiology department and hospital computerised information systems were used to identify and collate information regarding the indication, previous and follow-up imaging, CEUS findings and subsequent final diagnoses of patients who underwent hepatic CEUS from 12/12/2007 to 20/4/2012. RESULTS A total of 388 hepatic CEUS were performed, examining 409 lesions. The cases were grouped as either 'initial study' or 'follow-up' group, with main focus on the former group. Of the 367 lesions in the 'initial study' group, CEUS was able to distinguish benign from malignant pathology in 344 cases (93.8%). This was especially beneficial in setting of known malignancy with indeterminate liver lesions found on CT to confidently exclude metastatic disease. For 124 of 162 patients who had an incidentally detected indeterminate liver lesion, CEUS was the final imaging investigation required to make a diagnosis. CONCLUSION CEUS is a valuable tool in assessment of focal liver lesions in conjunction with other conventional modalities in a variety of clinical settings. In particular, it provided definitive diagnosis in a significant proportion of incidentally identified liver lesions many of which are benign, saving patient anxiety and further unnecessary follow-up.
Collapse
Affiliation(s)
- So Yeun Won
- Radiology Department, Concord Repatriation Hospital, Sydney
| | | | | | | | | |
Collapse
|
46
|
Alzaraa A, Gravante G, Chung WY, Al-Leswas D, Morgan B, Dennison A, Lloyd D. Contrast-enhanced ultrasound in the preoperative, intraoperative and postoperative assessment of liver lesions. Hepatol Res 2013; 43:809-19. [PMID: 23745715 DOI: 10.1111/hepr.12044] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2012] [Revised: 12/04/2012] [Accepted: 12/10/2012] [Indexed: 12/12/2022]
Abstract
The use of contrast agents (CA) with liver ultrasound (US) has gained recently an established role for the diagnosis of various hepatic diseases due to their safety, high versatility and low costs (contrast-enhanced ultrasound: CEUS). The purpose of this review is to provide a state-of-the-art summary of the available evidence for their use in the characterization of focal liver lesions. A published work search was conducted for all preclinical and clinical studies involving CA on hepatic US imaging. CEUS increases the sensitivity for lesion detection and the specificity to differentiate between benign and malignant diseases due to the enhanced visualization of the tumor microcirculation. Results achieved seem at least equivalent to those of spiral computed tomography or magnetic resonance imaging. The association of CA with intraoperative ultrasound has changed the surgical approach in 25% of patients and guarantees complete ablations by a single session in most of them. CEUS provides detailed information about tumor vasculature, improves the preoperative characterization and therefore the therapeutic strategy, and can evaluate the intraoperative completeness of the ablation.
Collapse
Affiliation(s)
- Ahmed Alzaraa
- Department of General Surgery, William Harvey Hospital, Ashford
| | | | | | | | | | | | | |
Collapse
|
47
|
Giannetti A, Franci L, Grechi C, Giangregorio F. Contrast-enhanced sonography in the diagnosis of hepatic hemangiomas: atypical appearance due to the washout of microbubbles. JOURNAL OF CLINICAL ULTRASOUND : JCU 2013; 41:361-365. [PMID: 22610668 DOI: 10.1002/jcu.21939] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2011] [Accepted: 03/28/2012] [Indexed: 06/01/2023]
Abstract
Contrast-enhanced sonography (CEUS) examination permits identification of hemangioma of the liver in most cases. This method is particularly useful when the ultrasound pattern is atypical on standard grayscale examination. CEUS appearances suggestive of hemangioma are peripheral globular enhancement, progression of enhancement toward the center of the nodule, and persistence of enhancement in the late phase. We present seven cases of hemangioma, which were atypical on CEUS examination due to washout during the portal and late phases, resulting in a hypoenhanced appearance compared with the adjacent liver parenchyma.
Collapse
|
48
|
Contrast-enhanced ultrasound detects perfusion defects in an ex vivo porcine liver model: a useful tool for the study of hepatic reperfusion. J Artif Organs 2013; 16:475-82. [DOI: 10.1007/s10047-013-0717-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Accepted: 06/11/2013] [Indexed: 01/01/2023]
|
49
|
Jang JY, Kim MY, Jeong SW, Kim TY, Kim SU, Lee SH, Suk KT, Park SY, Woo HY, Kim SG, Heo J, Baik SK, Kim HS, Tak WY. Current consensus and guidelines of contrast enhanced ultrasound for the characterization of focal liver lesions. Clin Mol Hepatol 2013; 19:1-16. [PMID: 23593604 PMCID: PMC3622850 DOI: 10.3350/cmh.2013.19.1.1] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2012] [Revised: 03/08/2012] [Accepted: 03/14/2012] [Indexed: 12/12/2022] Open
Abstract
The application of ultrasound contrast agents (UCAs) is considered essential when evaluating focal liver lesions (FLLs) using ultrasonography (US). Microbubble UCAs are easy to use and robust; their use poses no risk of nephrotoxicity and requires no ionizing radiation. The unique features of contrast enhanced US (CEUS) are not only noninvasiveness but also real-time assessing of liver perfusion throughout the vascular phases. The later feature has led to dramatic improvement in the diagnostic accuracy of US for detection and characterization of FLLs as well as the guidance to therapeutic procedures and evaluation of response to treatment. This article describes the current consensus and guidelines for the use of UCAs for the FLLs that are commonly encountered in US. After a brief description of the bases of different CEUS techniques, contrast-enhancement patterns of different types of benign and malignant FLLs and other clinical applications are described and discussed on the basis of our experience and the literature data.
Collapse
Affiliation(s)
- Jae Young Jang
- Institute for Digestive Research, Digestive Disease Center, Department of Internal Medicine, Soonchunhyang University College of Medicine, Seoul, Korea
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Williams R, Wright C, Cherin E, Reznik N, Lee M, Gorelikov I, Foster FS, Matsuura N, Burns PN. Characterization of submicron phase-change perfluorocarbon droplets for extravascular ultrasound imaging of cancer. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:475-89. [PMID: 23312960 DOI: 10.1016/j.ultrasmedbio.2012.10.004] [Citation(s) in RCA: 121] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Revised: 08/27/2012] [Accepted: 10/02/2012] [Indexed: 05/13/2023]
Abstract
Because many tumors possess blood vessels permeable to particles with diameters of 200 nm, it is possible that submicron perfluorocarbon droplets could constitute a novel extravascular ultrasound contrast agent capable of selectively enhancing tumors. Under exposure to bursts of ultrasound of sufficient rarefactional pressure, droplets can undergo vaporization to form echogenic microbubbles. In this study, phase-change thresholds of 220-nm-diameter droplets composed of perfluoropentane were studied in polyacrylamide gel phantoms maintained at temperatures of 21-37°C, exposed to high-pressure bursts of ultrasound with frequencies ranging from 5-15 MHz and durations of 1 μs to 1 ms. The thresholds were found to depend inversely and significantly (p < 0.001) on ultrasound frequency, pulse duration, and droplet temperature, ranging from 9.4 ± 0.8 MPa at 29°C for a 1-μs burst at 5 MHz to 3.2 ± 0.5 MPa at 37°C for a 1-ms burst at 15 MHz. The diameters of microbubbles formed from droplets decreased significantly as phantom stiffness increased (p < 0.0001), and were independent of pulse duration, although substantially more droplets were converted to microbubbles for 1-ms pulse durations compared with briefer exposures. In vivo experiments in a mouse tumor model demonstrated that intravenously injected droplets can be converted into highly echogenic microbubbles 1 h after administration.
Collapse
Affiliation(s)
- Ross Williams
- Imaging Research, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada M4N 3M5.
| | | | | | | | | | | | | | | | | |
Collapse
|