Christopher N, Periaswamy G, Arunachalam VK, Pilli V, Renganathan R, Rajasekaran S, Mehta P, Cherian M. Comparison of Turbo Flash and dual-energy modes of third-generation dual-source CT in pre-transplant renal angiography: a prospective observational study. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2022. [DOI: 10.1186/s43055-022-00876-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
The purpose of this study was to compare the Image Quality, Contrast Medium Volume, and Radiation dose in renal angiography performed using Turbo Flash mode and dual-energy (DE) mode in the third-generation dual-source dual-energy CT.
This prospective observational study was performed on renal donors who underwent CTA imaging as a pre-transplant workup. The study population was divided into two groups. Group A underwent DECT renal angiography. Group B underwent Turbo Flash Mode CT renal angiography. For group A, a contrast volume of 1 ml/kg and for group B at 0.5 ml/kg was administered. Image Quality was evaluated objectively by calculating CNR and SNR and subjectively by a 5-point scale. Radiation Dose analysis was done by noting CTDIvol and DLP on the scanner system and calculating effective radiation dose (ED).
Results
The subjective image quality scores for the Turbo Flash group were comparable with the DE group in qualitative image analysis. Additionally, in the Turbo Flash group, there was a reduction in contrast media and effective radiation dose by 47.5% and 32.7%, respectively. Nevertheless, mean attenuation of the abdominal arteries, CNR, SNR, and Noise (S.D) showed statistical significance between the two groups (p value < 0.01).
Conclusions
To our knowledge, no previous study compared Turboflash mode with DE protocol in CT renal angiography in a donor group of patients. Turbo Flash CT is an excellent modality that is faster and has an added advantage of decreased radiation dose and contrast media volume reduction, which can be recommended for screening of voluntary kidney donors but needs further clinical studies, validation, and standardization with tailored protocols.
Collapse
|
2
|
Richards CE, Obaid DR. Low-Dose Radiation Advances in Coronary Computed Tomography Angiography in the Diagnosis of Coronary Artery Disease. Curr Cardiol Rev 2019; 15:304-315. [PMID: 30806322 PMCID: PMC8142354 DOI: 10.2174/1573403x15666190222163737] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 12/24/2018] [Accepted: 12/26/2018] [Indexed: 01/16/2023] Open
Abstract
Background
Coronary computed tomography angiography (CCTA) is now widely used in the diagnosis of coronary artery disease since it is a rapid, minimally invasive test with a diagnostic accuracy comparable to coronary angiography. However, to meet demands for increasing spatial and temporal resolution, higher x-ray radiation doses are required to circumvent the resulting increase in image noise. Exposure to high doses of ionizing radiation with CT imaging is a major health concern due to the potential risk of radiation-associated malignancy. Given its increasing use, a number of dose saving algorithms have been implemented to CCTA to minimize radiation exposure to “as low as reasonably achievable (ALARA)” without compromising diagnostic image quality. Objective
The purpose of this review is to outline the most recent advances and current status of dose saving techniques in CCTA. Method
PubMed, Medline, EMBASE and Scholar databases were searched to identify feasibility studies, clinical trials, and technology guidelines on the technical advances in CT scanner hardware and reconstruction software. Results
Sub-millisievert (mSv) radiation doses have been reported for CCTA due to a combination of strategies such as prospective electrocardiogram-gating, high-pitch helical acquisition, tube current modulation, tube voltage reduction, heart rate reduction, and the most recent novel adaptive iterative reconstruction algorithms. Conclusion
Advances in radiation dose reduction without loss of image quality justify the use of CCTA as a non-invasive alternative to coronary catheterization in the diagnosis of coronary artery disease.
Collapse
Affiliation(s)
- Caryl E Richards
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom
| | - Daniel R Obaid
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom.,Swansea University Medical School, Swansea University, Grove Building, Singleton Park, Sketty, Swansea SA2 8PP, United Kingdom
| |
Collapse
|
3
|
Smettei OA, Sayed S, M Al Habib A, Alharbi F, Abazid RM. Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: Comparison of image quality and patient radiation exposure. J Saudi Heart Assoc 2018; 30:165-171. [PMID: 29983492 PMCID: PMC6026393 DOI: 10.1016/j.jsha.2017.11.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Revised: 09/27/2017] [Accepted: 11/02/2017] [Indexed: 01/08/2023] Open
Abstract
Background Coronary computed tomography angiography (CCTA) is increasingly being used for the evaluation of coronary artery disease; however, radiation exposure remains a major limitation of its use. Objective To compare image quality and radiation exposure in two groups of patients undergoing CCTA using a 256-slice dual-source helical computed tomography scanner with high-pitch (FLASH) or prospective [step-and-shoot (SAS)] gating protocols. Methods A prospective, single-center study was performed in our cardiac center. In total, 162 patients underwent CCTA with either FLASH or SAS scanning protocols. Subjective image quality was graded on the basis of a four-point grading system (1, non-diagnostic; 2, adequate; 3, good; 4, excellent). Objective image quality was assessed using image signal, noise, and signal-to-noise ratio (SNR). The effective radiation dose was also estimated. Results The clinical and demographic characteristics of the patients in both groups were similar. The median age of the patients in both groups was 48.43 years, and males accounted for 63% and 68.7% of the FLASH and SAS groups, respectively. We found that the subjective image quality obtained with the FLASH protocol was superior to that obtained with the SAS protocol (3.35 ± 0.6 mSv vs. 2.82 ± 0.61 mSv; p < 0.001). Image noise was higher in the FLASH group but was not statistically significant (25.0 ± 6.13 vs. 24.0 ± 6.8; p = 0.10), whereas the signal and SNR was significantly higher with the FLASH protocol than with the SAS protocol [(469 ± 116 vs. 397 ± 106; p > 0.001) and (21.6 ± 8.7 mSv vs. 16.6 ± 7.7 mSv; p < 0.001), respectively]. Radiation exposure was 62% lower in the FLASH protocol than in the SAS protocol, (1.9 ± 0.4 mSv vs. 5.12 ± 1.8 mSv; p < 0.001). Conclusion The use of 256-slice CCTA performed with the FLASH protocol has a better objective and subjective image quality as well as lower radiation exposure when compared with the use of prospective electrocardiography gating.
Collapse
Affiliation(s)
- Osama A Smettei
- Department of Cardiology, Cardiac Imaging Department, Prince Sultan Cardiac Center, Qassim PSCCQ, Buraydah, Saudi Arabiaa
| | - Sawsan Sayed
- Department of Cardiology, Cardiac Imaging Department, Prince Sultan Cardiac Center, Qassim PSCCQ, Buraydah, Saudi Arabiaa
| | - Abdullah M Al Habib
- Department of Radiology, King Fahad Specialist Hospital, Qassim, Saudi Arabiab
| | - Fahad Alharbi
- Department of Radiology, King Fahad Specialist Hospital, Qassim, Saudi Arabiab
| | - Rami M Abazid
- Department of Cardiology, Cardiac Imaging Department, Prince Sultan Cardiac Center, Qassim PSCCQ, Buraydah, Saudi Arabiaa
| |
Collapse
|
4
|
Duvall WL, Tandon TS, Henzlova MJ. The time is now: Dose reduction for myocardial perfusion imaging. J Nucl Cardiol 2018; 25:131-133. [PMID: 27535414 DOI: 10.1007/s12350-016-0639-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Accepted: 07/29/2016] [Indexed: 10/21/2022]
Affiliation(s)
- W Lane Duvall
- Division of Cardiology, Hartford Hospital, Hartford, CT, USA.
| | - Tarun S Tandon
- Division of Cardiology, Hartford Hospital, Hartford, CT, USA
| | - Milena J Henzlova
- Division of Cardiology, Mount Sinai Medical Center, New York, NY, USA
| |
Collapse
|
5
|
Goo HW. Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction. Korean J Radiol 2018; 19:23-31. [PMID: 29353996 PMCID: PMC5768502 DOI: 10.3348/kjr.2018.19.1.23] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Accepted: 07/04/2017] [Indexed: 11/17/2022] Open
Abstract
Objective To compare radiation doses between conventional and chest pain protocols using dual-source retrospectively electrocardiography (ECG)-gated cardiothoracic computed tomography (CT) in children and adults and assess the effect of tube current saturation on radiation dose reduction. Materials and Methods This study included 104 patients (16.6 ± 7.7 years, range 5–48 years) that were divided into two groups: those with and those without tube current saturation. The estimated radiation doses of retrospectively ECG-gated spiral cardiothoracic CT were compared between conventional, uniphasic, and biphasic chest pain protocols acquired with the same imaging parameters in the same patients by using paired t tests. Dose reduction percentages, patient ages, volume CT dose index values, and tube current time products per rotation were compared between the two groups by using unpaired t tests. A p value < 0.05 was considered significant. Results The volume CT dose index values of the biphasic chest pain protocol (10.8 ± 3.9 mGy) were significantly lower than those of the conventional protocol (12.2 ± 4.7 mGy, p < 0.001) and those of the uniphasic chest pain protocol (12.9 ± 4.9 mGy, p < 0.001). The dose-saving effect of biphasic chest pain protocol was significantly less with a saturated tube current (4.5 ± 10.2%) than with unsaturated tube current method (14.8 ± 11.5%, p < 0.001). In 76 patients using 100 kVp, patient age showed no significant differences between the groups with and without tube current saturation in all protocols (p > 0.05); the groups with tube current saturation showed significantly higher volume CT dose index values (p < 0.01) and tube current time product per rotation (p < 0.001) than the groups without tube current saturation in all protocols. Conclusion The radiation dose of dual-source retrospectively ECG-gated spiral cardiothoracic CT can be reduced by approximately 15% by using the biphasic chest pain protocol instead of the conventional protocol in children and adults if radiation dose parameters are further optimized to avoid tube current saturation.
Collapse
Affiliation(s)
- Hyun Woo Goo
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea
| |
Collapse
|
6
|
Whole-Body High-Pitch CT Angiography: Strategies to Reduce Radiation Dose and Contrast Volume. AJR Am J Roentgenol 2017; 209:1396-1403. [DOI: 10.2214/ajr.16.17695] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
7
|
Koplay M, Guneyli S, Akbayrak H, Demir K, Sivri M, Avci A, Erdogan H, Paksoy Y. Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency. Wien Klin Wochenschr 2016; 128:488-94. [PMID: 27343083 DOI: 10.1007/s00508-016-1030-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 06/04/2016] [Indexed: 10/21/2022]
Abstract
OBJECTIVE The aim of the study was to evaluate the diagnostic accuracy and effective radiation dose (ERD) of high pitch dual source multidetector computed tomography (MDCT) for coronary artery bypass graft (CABG) patency. MATERIALS AND METHODS Fourty-five patients who underwent 128 × 2‑slice MDCT angiography with a prospective electrocardiogram-triggering, low-dose, high pitch, dual source, flash spiral acquisition mode after CABG surgery were included in the study. The interobserver agreement of the image quality was evaluated with Cohen κ value. The image quality was compared to the heart rates (HRs) using Mann-Whitney U test and to the graft segments using χ(2) test. The findings for the CABG patency on MDCT were compared to those determined on catheter coronary angiography. Dose-length product (DLP) and ERD were compared to the gender, HRs, and body mass index (BMI) of the patients using Kruskall Wallis and Mann-Whitney U tests. RESULTS A total of 110 grafts and 330 vessel segments were evaluated with a good interobserver agreement (κ = 0.80). The image quality was better in proximal and middle graft segments (p < 0.05), as well as in the patients with low HRs (p < 0.05). High pitch MDCT had the following sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for evaluation of graft patency: 92.8, 99.3, 92.8, 99.3 and 98.8 %, respectively. ERD was correlated to the HRs and BMI. CONCLUSIONS High pitch 128 × 2‑slice dual source CT angiography is a noninvasive imaging modality, and it can be safely and effectively used in evaluation of CABG patency with lower radiation dose.
Collapse
Affiliation(s)
- Mustafa Koplay
- Department of Radiology, Medical Faculty, Selcuk University, The Central Campus, 42075, Konya, Turkey.
| | - Serkan Guneyli
- Department of Radiology, Medical Faculty, Bulent Ecevit University, Zonguldak, Turkey
| | - Hakan Akbayrak
- Department of Cardiovascular Surgery, Medical Faculty, Selcuk University, Konya, Turkey
| | - Kenan Demir
- Department of Cardiology, Medical Faculty, Selcuk University, Konya, Turkey
| | - Mesut Sivri
- Department of Radiology, Medical Faculty, Selcuk University, The Central Campus, 42075, Konya, Turkey
| | - Ahmet Avci
- Department of Cardiology, Medical Faculty, Selcuk University, Konya, Turkey
| | - Hasan Erdogan
- Department of Radiology, Medical Faculty, Selcuk University, The Central Campus, 42075, Konya, Turkey
| | - Yahya Paksoy
- Department of Radiology, Medical Faculty, Selcuk University, The Central Campus, 42075, Konya, Turkey
| |
Collapse
|
8
|
Marcus R, Ruff C, Burgstahler C, Notohamiprodjo M, Nikolaou K, Geisler T, Schroeder S, Bamberg F. Evidencia científica reciente y avances técnicos en la tomografía computarizada cardiovascular. Rev Esp Cardiol 2016. [DOI: 10.1016/j.recesp.2015.12.023] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
9
|
Marcus R, Ruff C, Burgstahler C, Notohamiprodjo M, Nikolaou K, Geisler T, Schroeder S, Bamberg F. Recent Scientific Evidence and Technical Developments in Cardiovascular Computed Tomography. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2016; 69:509-14. [PMID: 27025303 DOI: 10.1016/j.rec.2015.12.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2015] [Accepted: 12/27/2015] [Indexed: 10/22/2022]
Abstract
In recent years, coronary computed tomography angiography has become an increasingly safe and noninvasive modality for the evaluation of the anatomical structure of the coronary artery tree with diagnostic benefits especially in patients with a low-to-intermediate pretest probability of disease. Currently, increasing evidence from large randomized diagnostic trials is accumulating on the diagnostic impact of computed tomography angiography for the management of patients with acute and stable chest pain syndrome. At the same time, technical advances have substantially reduced adverse effects and limiting factors, such as radiation exposure, the amount of iodinated contrast agent, and scanning time, rendering the technique appropriate for broader clinical applications. In this work, we review the latest developments in computed tomography technology and describe the scientific evidence on the use of cardiac computed tomography angiography to evaluate patients with acute and stable chest pain syndrome.
Collapse
Affiliation(s)
- Roy Marcus
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Germany
| | - Christer Ruff
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Germany
| | | | - Mike Notohamiprodjo
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Germany
| | - Tobias Geisler
- Department of Cardiology, University of Tuebingen, Tuebingen, Germany
| | - Stephen Schroeder
- Department of Internal Medicine, Klinikum Göppingen, Göppingen, Germany
| | - Fabian Bamberg
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Germany.
| |
Collapse
|
10
|
Lim HK, Ha HI, Hwang HJ, Lee K. Feasibility of high-pitch dual-source low-dose chest CT: Reduction of radiation and cardiac artifacts. Diagn Interv Imaging 2016; 97:443-9. [PMID: 26896374 DOI: 10.1016/j.diii.2016.01.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2015] [Revised: 01/07/2016] [Accepted: 01/07/2016] [Indexed: 11/17/2022]
Abstract
PURPOSE To compare the radiation dose and image quality, focused mainly on cardiac pulsation artifact, between high-pitch low-dose chest computed tomography (HP-LDCT) and standard low-dose chest CT (LDCT). PATIENTS AND METHODS One hundred patients underwent HP-LDCT (50 patients) or LDCT (50 patients). Scan parameters were the same except for the pitch and gantry rotation time: 3.0 vs. 1.2 and 0.28s vs. 0.5s, respectively. Objective image noise at five regions and subjective image quality, such as noise, artifacts, cardiac pulsation artifacts, and overall diagnostic acceptability, were evaluated using a five-point scale. The significance level for all tests was set at P<0.05. RESULTS The dose-length products (DLPs) with HP-LDCT and LDCT were 90.2±4.3mGycm and 103.1±6.4mGycm, respectively (P<0.01). DLP of HP-LDCT showed a 13% reduction versus LDCT. Objective image noise was not significantly different. Cardiac pulsation artifacts showed a significant reduction on HP-LDCT (P<0.01). Other subjective image quality parameters of HP-LDCT were similar to those of LDCT. The overall diagnostic acceptability of HP-LDCT was better than that of LDCT (P<0.01). CONCLUSIONS HP-LDCT showed a 13% mean radiation dose reduction with no deterioration in image quality due to cardiac pulsation artifacts.
Collapse
Affiliation(s)
- H K Lim
- Department of Radiology, Soonchunhyang University Seoul Hospital, 59 Daesagwan-ro, Yongsan-gu, Seoul, 140-743, Republic of Korea.
| | - H I Ha
- Department of Radiology, Hallym University Medical Center, Hallym University Sacred Heart Hospital, 896 Pyeongchon-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-070, Republic of Korea.
| | - H J Hwang
- Department of Radiology, Hallym University Medical Center, Hallym University Sacred Heart Hospital, 896 Pyeongchon-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-070, Republic of Korea.
| | - K Lee
- Department of Radiology, Hallym University Medical Center, Hallym University Sacred Heart Hospital, 896 Pyeongchon-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-070, Republic of Korea.
| |
Collapse
|
11
|
Low-Voltage, High-Pitch Computerized Tomography Angiography of the Infrarenal Aorta and Lower Extremity Vessels: Assessment of Radiation Dose, Image Quality With Hybrid Iterative Reconstruction, and Efficacy of Test Injection Using a Monitoring Scan at Knee Level. J Comput Assist Tomogr 2016; 40:402-8. [PMID: 26854413 DOI: 10.1097/rct.0000000000000365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Our aim was to assess image quality and radiation dose of low-voltage high-pitch computed tomography angiography of the infrarenal aorta and lower extremities and evaluate the efficacy of test injection technique using a monitoring scan at knee level. METHODS A total of 60 patients with suspected peripheral arterial disease were divided into 2 groups: group 1 (30 patients, 80 kVp, high pitch [3.2], and hybrid iterative reconstruction [sinogram-affirmed iterative reconstruction]) and group 2 (30 patients, 120 kVp, low pitch [1.0], and filtered back projection reconstruction). The test injection technique at knee level was used to determine the scan delay time in group 1. The image quality and radiation exposure were compared. RESULTS There were significant differences between the 2 groups in mean (SD) arterial attenuation (80 vs 120 kVp: 507.78 [103.01] vs 317.54 [62.03] Hounsfield units, P < 0.001), mean (SD) signal-to-noise ratio (51.04 [20.29] vs 34.66 [9.94], P < 0.001), and contrast-to-noise ratio (44.83 [17.93] vs 28.26 [9.60], P < 0.001). No difference in subjective image quality was found between the 2 groups (all P > 0.05). The imaging time was significantly shorter in group 1 (2.70 [0.11] vs 14.65 [0.90s], P < 0.001). The mean (SD) effective dose was significantly lower in the 80 kVp group (0.76 [0.06] vs 4.29 [0.63] mSv, P < 0.001). CONCLUSIONS The 80-kVp high-pitch computed tomography angiography of the lower limbs using sinogram-affirmed iterative reconstruction yields reduction of radiation exposure as well as obtains acceptable image quality if acquisition protocols are used in conjunction with the test injection technique using monitoring scan at knee level to determine the delay time.
Collapse
|
12
|
High pitch CT in triple rule-out studies: Radiation dose and image quality compared to multidetector CT. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.rxeng.2015.07.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
13
|
Fernández del Valle A, Delgado Sánchez-Gracián C, Oca Pernas R, Grande Astorquiza A, Bustos Fiore A, Trinidad López C, Tardáguila de la Fuente G. Tomografía computarizada de pitch alto en estudios de triple descarte: dosis de radiación y calidad de la imagen comparada con la de la tomografía computarizada multidetector. RADIOLOGIA 2015; 57:412-8. [DOI: 10.1016/j.rx.2014.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2014] [Revised: 07/04/2014] [Accepted: 07/09/2014] [Indexed: 10/24/2022]
|
14
|
Liguori C, Frauenfelder G, Massaroni C, Saccomandi P, Giurazza F, Pitocco F, Marano R, Schena E. Emerging clinical applications of computed tomography. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2015; 8:265-78. [PMID: 26089707 PMCID: PMC4467659 DOI: 10.2147/mder.s70630] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
X-ray computed tomography (CT) has recently been experiencing remarkable growth as a result of technological advances and new clinical applications. This paper reviews the essential physics of X-ray CT and its major components. Also reviewed are recent promising applications of CT, ie, CT-guided procedures, CT-based thermometry, photon-counting technology, hybrid PET-CT, use of ultrafast-high pitch scanners, and potential use of dual-energy CT for material differentiations. These promising solutions and a better knowledge of their potentialities should allow CT to be used in a safe and effective manner in several clinical applications.
Collapse
Affiliation(s)
| | | | - Carlo Massaroni
- Measurement and Biomedical Instrumentation Unit, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Paola Saccomandi
- Measurement and Biomedical Instrumentation Unit, Università Campus Bio-Medico di Roma, Rome, Italy
| | | | | | - Riccardo Marano
- Department of Radiological Sciences, Institute of Radiology, Catholic University of Rome, A Gemelli University Hospital, Rome, Italy
| | - Emiliano Schena
- Measurement and Biomedical Instrumentation Unit, Università Campus Bio-Medico di Roma, Rome, Italy
| |
Collapse
|
15
|
Gordic S, Alkadhi H. [Investigation techniques and importance of CT for diagnostics of cardiac valvular diseases]. Radiologe 2014; 53:864-71. [PMID: 24002182 DOI: 10.1007/s00117-012-2469-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
CLINICAL/METHODICAL ISSUE Cardiac computed tomography (CT) is the first-line modality for coronary assessment. In addition valvular morphology and function can be evaluated. STANDARD RADIOLOGICAL METHODS The method of choice for the evaluation of cardiac valves is echocardiography, followed by magnetic resonance imaging. METHODICAL INNOVATIONS Recent technical improvements and advances in temporal resolution allow a detailed anatomical and functional evaluation of the cardiac valves. PERFORMANCE Cardiac CT provides an excellent image quality of the aortic and mitral valve thus enabling an evaluation of the morphology. In addition, cardiac CT allows an assessment of aortic valve function with respect to the grading of stenosis and regurgitation. ACHIEVEMENTS Cardiac CT is not considered the first-line modality for the evaluation of cardiac valves; however, beyond coronary assessment CT provides important information on the morphology and function of cardiac valves. PRACTICAL RECOMMENDATIONS Cardiac CT can be a useful imaging alternative for patients in whom other more commonly used methods, such as echocardiography and magnetic resonance imaging fail to provide the necessary information.
Collapse
Affiliation(s)
- S Gordic
- Institut für Diagnostische und Interventionelle Radiologie, Universitätsspital Zürich, Rämistr. 100, 8091, Zürich, Schweiz,
| | | |
Collapse
|
16
|
Feasibility of low-dose contrast medium high pitch CT angiography for the combined evaluation of coronary, head and neck arteries. PLoS One 2014; 9:e90268. [PMID: 24595301 PMCID: PMC3940874 DOI: 10.1371/journal.pone.0090268] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Accepted: 01/28/2014] [Indexed: 11/29/2022] Open
Abstract
Purpose To evaluate the image quality and radiation dose of combined heart, head, and neck CT angiography (CTA) using prospectively electrocardiography (ECG)-triggered high-pitch spiral scan protocol, compared with single coronary CTA. Materials and Methods 151 consecutive patients were prospectively included and randomly divided into three groups. Group 1 (n = 47) underwent combined heart, neck, and head CTA using prospectively ECG-triggered high-pitch spiral (Flash) scan protocol with a single-phase intravenous injection of iodinated contrast and saline flush; Group 2 (n = 51) underwent single coronary CTA with Flash scan protocol; and Group 3 (n = 53) underwent single coronary CTA with prospective sequence scan protocol. All patients were examined on a dual source CT (Definition FLASH). The image quality was determined for each CT study. Results Patients of scanning protocol Group 1, 2, and 3 showed no significant differences in age, sex, heart rates, and BMI. Evaluation of coronary artery image quality showed comparable results in the three scanning protocol groups on a per patient-based analysis. In group 1, image quality was found to be sufficient to be diagnostic in all arterial segments of carotid arteries. The mean dose-length product (DLP) for group 1 was 256.3±24.5 mGy×cm and was significantly higher in comparison with group 2 (93.4±19.9 mGy×cm; p < 0.001). However, there was no significant difference of DLP between group 1 and group 3 (254.1±69.9 mGy×cm). Conclusions The combined heart, neck, and head arteries scan using prospectively electrocardiography (ECG)-triggered high-pitch spiral scan protocol in 1 single examination resulted in an excellent opacification of the aorta, the carotid arteries, and the coronary arteries and provided a good image quality with low radiation dose.
Collapse
|
17
|
Heye T, Kauczor HU, Szabo G, Hosch W. Computed tomography angiography of coronary artery bypass grafts: robustness in emergency and clinical routine settings. Acta Radiol 2014; 55:161-70. [PMID: 23908242 DOI: 10.1177/0284185113494977] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
BACKGROUND There is a high probability for presence of irregular heart rates and artifacts in patients with previous coronary artery bypass graft (CABG) surgery. Previously reported diagnostic performance of ECG-gated 64-slice dual-source computer tomography angiography (CTA) in this patient group is based on pre-selection for normal heart rate and routine clinical setting. PURPOSE To investigate image quality and diagnostic performance of CTA in patients with previous CABG surgery in various clinical settings. MATERIAL AND METHODS Fifty-six non-selected, consecutive patients (110 grafts, 44 arterial, 66 venous) with previous CABG surgery were prospectively examined using a dual-source 64-slice CT (Siemens Definition, Forchheim, Germany) without utilization of CT-related pharmaceutical heart rate control. Patients were stratified according to the clinical setting: planned redo-cardiac surgery; emergency CTA within 30 days after CABG surgery; routine follow-up after CABG surgery. A reference standard was available for 30 patients (53.6%; 67/110 grafts). Image quality, artifacts, and graft patency were independently assessed by two observers. RESULTS All CTAs were diagnostic despite the presence of irregular heart rhythm (25% of cases) and artifacts (72.7% of grafts). CTA was accurate in all patient groups in assessing graft patency (97.9% sensitivity; 100% specificity; 98.5% accuracy) but artifacts decreased diagnostic performance for stenosis detection (60% sensitivity; 88.6% specificity; 84.1% accuracy). Arterial grafts exhibited more surgical clip artifacts compared to venous grafts, which predominantly showed motion artifacts. Overall diagnostic quality was rated excellent in 70.9%/56.4%, good in 23.4%/39.1%, and sufficient in 5.5%/4.5% by each observer, respectively. CTA detected acute findings in 10 cases (graft bleeding, graft occlusion, pericardial hematoma, sternal instability with retrosternal abscess formation, pericardial effusion, left ventricle thrombus) in the emergency group; seven cases required surgical revision. CONCLUSION Dual-source CTA is a robust and accurate method for assessment of graft patency and detection of relevant extra-cardiac pathologies in a non-selected patient population after CABG surgery in routine as well as emergency clinical settings. Artifacts caused by irregular heart rhythm or surgical clips do not impair graft patency evaluation but limit stenosis assessment.
Collapse
Affiliation(s)
- Tobias Heye
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
- Department of Radiology and Nuclear Medicine, University Hospital Basel, Basel, Switzerland
| | - Hans-Ulrich Kauczor
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Gabor Szabo
- Department of Cardiothoracic Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Waldemar Hosch
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| |
Collapse
|
18
|
Christensen JD, Seaman DM, Lungren MP, Hurwitz LM, Boll DT. Assessment of vascular contrast and wall motion of the aortic root and ascending aorta on MDCT angiography: dual-source high-pitch vs non-gated single-source acquisition schemes. Eur Radiol 2014; 24:990-7. [PMID: 24573567 DOI: 10.1007/s00330-014-3120-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2013] [Revised: 01/31/2014] [Accepted: 02/10/2014] [Indexed: 12/18/2022]
Abstract
OBJECTIVES This retrospective study assessed whether dual-source high-pitch computed tomographic angiography (CTA) offered advantages over single-source standard-pitch techniques in the evaluation of the ascending aorta. METHODS Twenty patients who received both thoracic dual-source high-pitch and single-source standard-pitch CTAs within 1 year were assessed. Dual-source CTAs were performed; standard-pitch imaging used dose-modulated 120 kVp/150 mAs and 0.8 pitch compared with high-pitch protocols employing dose-modulated 120 kVp/250 mAs and 2.4 target pitch. Radiation dose was documented. Contrast-to-noise ratios (CNRs) at sinuses of the Valsalva (CNRValsalva) and ascending aorta (CNRAorta) were calculated. Dose/CNR for each technique was compared with paired t-tests. Motion at aortic valve, aortic root and ascending aorta were assessed with four-point scales and Mann-Whitney U tests; longitudinal extension of motion was compared with paired t-tests. RESULTS Significantly lower motion scores for high-pitch, compared with standard-pitch acquisitions for aortic annulus, 0 vs. 2, aortic root, 0 vs. 3, and ascending aorta, 0 vs. 2, were achieved. Significantly reduced longitudinal extension of motion at aortic root, 4.9 mm vs 15.7 mm, and ascending aorta, 4.9 mm vs 21.6 mm, was observed. Contrast was not impacted: CNRValsalva, 45.6 vs 46.3, and CNRAorta, 45.3 vs 47.1. CTDIvol was significantly decreased for high-pitch acquisitions, 13.9 mGy vs 15.8 mGy. CONCLUSIONS Dual-source high-pitch CTAs significantly decreased motion artefact without negatively impacting vascular contrast and radiation dose. KEY POINTS • Dual-source high-pitch CTA significantly decreased motion artefact of the ascending aorta. • Dual-source high-pitch CTA did not negatively impact on vascular contrast. • Dual-source high-pitch CTA significantly decreased radiation dose compared with single-source standard-pitch acquisitions.
Collapse
Affiliation(s)
- Jared D Christensen
- Department of Radiology, Duke University Medical Center, Durham, NC, 27710, USA
| | | | | | | | | |
Collapse
|
19
|
|
20
|
Shohji T, Higuchi S, Iida T, Inagaki K, Katou Y. [Usefulness of criterion on which to operate coronary computed tomography angiography used dual source computed tomography comparisons with exposure dose of prospective electrocardiogram high-pitch spiral mode, low-pitch spiral mode, and step and shoot mode]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2013; 69:257-263. [PMID: 23514853 DOI: 10.6009/jjrt.2013_jsrt_69.3.257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We believe that the patient exposure dose differs by heart rate for a coronary computed tomography angiography (CCTA), and we attempted to reduce patient exposure dose of the CCTA. Specifically, we made a clear difference of exposure dose between heart rate and optimal cardiac phase or some imaging methods. Next, we established criterion of the CCTA in our hospital, and usefulness was discussed. For examination methods, patients with a heart rate below 60 beats per minute (bpm) received a high-pitch spiral scan (Flash Spiral mode), those between 61 to 70 bpm received a step and shoot scan (SAS mode), and those of >70 bpm or an irregular heart rate received low-pitch spiral scan (Helical mode). The results of the clinical study showed that patient exposure dose reduced 87% in Flash Spiral mode (1.93±0.26 mSv) and 66% in SAS mode (4.88±1.24 mSv) compared with Helical mode (14.35±3.42 mSv). In our present study, we proved the usefulness of our criteria using CCTA. If the results of our present study become guidelines of CCTA users, we suggest that total patient exposure dose can be reduced.
Collapse
Affiliation(s)
- Tomokazu Shohji
- Department of Radiology, The JIKEI University Kashiwa Hospital, Japan
| | | | | | | | | |
Collapse
|
21
|
Karaarslan E, Ulus S, Bavbek C. Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography. J Med Imaging Radiat Oncol 2013; 57:407-14. [PMID: 23870335 DOI: 10.1111/1754-9485.12036] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2012] [Accepted: 11/21/2012] [Indexed: 12/22/2022]
Abstract
INTRODUCTION Radiation exposure from computed tomography coronary angiography (CTCA) is of particular concern and several techniques have been introduced to lower the radiation dose. In this study, we aimed to compare the diagnostic image quality and estimated radiation dose of the three CTCA acquisition protocols in a recently introduced second generation dual-source computed tomography. METHODS Two hundred consecutive subjects underwent dual-source CTCA by using high-pitch spiral, sequential and retrospective spiral protocols. Effective radiation dose, expressed in millisieverts, was calculated as the product of the dose-length product times a conversion factor of 0.014. Image quality was evaluated on a per-segment basis, with a four-point scale. RESULTS For the high-pitch spiral, sequential and retrospective spiral protocols, mean effective radiation doses were 1.41 ± 0.56, 5.50 ± 2.06 and 7.79 ± 2.25 mSv and mean per-subject image scores were 2.8 ± 0.7, 2.2 ± 0.8 and 2.5 ± 0.8, respectively. Radiation dose of the high-pitch mode was significantly lower (P < 0.001) than the sequential and retrospective spiral modes, and statistical analysis for image quality revealed a significant difference between the high-pitch spiral and the sequential modes (P < 0.05). CONCLUSION Dual-source CTCA using high-pitch acquisition considerably lowers radiation exposure in subjects with a low and stable heart rate and maintains good image quality, especially when the subjects have a body mass index ≤25 and a tube voltage of 80 or 100 kV is used. However, when sequential and retrospective spiral modes are used in the same device, mean radiation doses can increase roughly three and five times more, respectively.
Collapse
Affiliation(s)
- Ercan Karaarslan
- Department of Radiology, Acibadem University School of Medicine, Istanbul, Turkey
| | | | | |
Collapse
|
22
|
Korn A, Fenchel M, Bender B, Danz S, Thomas C, Ketelsen D, Claussen CD, Moonis G, Krauss B, Heuschmid M, Ernemann U, Brodoefel H. High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose. Neuroradiology 2012; 55:423-30. [PMID: 23223824 DOI: 10.1007/s00234-012-1120-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2012] [Accepted: 11/13/2012] [Indexed: 01/31/2023]
Abstract
INTRODUCTION High-pitch CT angiography (CTA) is a recent innovation that allows significant shortening of scan time with volume coverage of 43 mm per second. The aim of our study was to assess this technique in CTA of the head and neck. METHODS CTA of supra-aortic arteries was performed in 50 patients using two acquisition protocols: conventional single-source 64-slice (pitch 1.2) and high-pitch dual-source 128-slice CT (pitch 3.2). Subjective and objective image quality of supra-aortic vessel ostia as well as intra- and extra-cranial segments was retrospectively assessed by blinded readers and radiation dose compared between the two protocols. RESULTS Conventional and high-pitch CTA achieved comparable signal-to-noise ratios in arterial (54.3 ± 16.5 versus 57.3 ± 14.8; p = 0.50) and venous segments (15.8 ± 6.7 versus 18.9 ± 8.9; p = 0.21). High-pitch scanning was, however, associated with sharper delineation of vessel contours and image quality significantly improved at the level of supra-aortic vessel ostia (p < 0.0001) as well as along the brachiocephalic trunk (p < 0.0001), the subclavian arteries (p < 0.0001), proximal common carotid arteries (p = 0.01), and vertebral V1 segments (p < 0.0001). Using the high-pitch mode, the dose-length product was reduced by about 35% (218.2 ± 30 versus 141.8 ± 20 mGy × cm). CONCLUSIONS Due to elimination of transmitted cardiac motion, high-pitch CTA of the neck improves image quality in the proximity of the aortic arch while significantly lowering radiation dose. The technique thus qualifies as a promising alternative to conventional spiral CTA and may be particularly useful for identification of ostial stenosis.
Collapse
Affiliation(s)
- A Korn
- Department of Diagnostic und Interventional Neuroradiology, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Sun K, Liu GR, Li YC, Han RJ, Cui LF, Ma LJ, Li LG, Li CY. Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography: Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique. ACTA ACUST UNITED AC 2012; 27:225-31. [DOI: 10.1016/s1001-9294(13)60006-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
24
|
Neefjes LA, Rossi A, Genders TSS, Nieman K, Papadopoulou SL, Dharampal AS, Schultz CJ, Weustink AC, Dijkshoorn ML, Ten Kate GJR, Dedic A, van Straten M, Cademartiri F, Hunink MGM, Krestin GP, de Feyter PJ, Mollet NR. Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols. Eur Radiol 2012; 23:614-22. [PMID: 23052644 DOI: 10.1007/s00330-012-2663-3] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2012] [Revised: 06/11/2012] [Accepted: 06/29/2012] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To compare the diagnostic performance and radiation exposure of 128-slice dual-source CT coronary angiography (CTCA) protocols to detect coronary stenosis with more than 50 % lumen obstruction. METHODS We prospectively included 459 symptomatic patients referred for CTCA. Patients were randomized between high-pitch spiral vs. narrow-window sequential CTCA protocols (heart rate below 65 bpm, group A), or between wide-window sequential vs. retrospective spiral protocols (heart rate above 65 bpm, group B). Diagnostic performance of CTCA was compared with quantitative coronary angiography in 267 patients. RESULTS In group A (231 patients, 146 men, mean heart rate 58 ± 7 bpm), high-pitch spiral CTCA yielded a lower per-segment sensitivity compared to sequential CTCA (89 % vs. 97 %, P = 0.01). Specificity, PPV and NPV were comparable (95 %, 62 %, 99 % vs. 96 %, 73 %, 100 %, P > 0.05) but radiation dose was lower (1.16 ± 0.60 vs. 3.82 ± 1.65 mSv, P < 0.001). In group B (228 patients, 132 men, mean heart rate 75 ± 11 bpm), per-segment sensitivity, specificity, PPV and NPV were comparable (94 %, 95 %, 67 %, 99 % vs. 92 %, 95 %, 66 %, 99 %, P > 0.05). Radiation dose of sequential CTCA was lower compared to retrospective CTCA (6.12 ± 2.58 vs. 8.13 ± 4.52 mSv, P < 0.001). Diagnostic performance was comparable in both groups. CONCLUSION Sequential CTCA should be used in patients with regular heart rates using 128-slice dual-source CT, providing optimal diagnostic accuracy with as low as reasonably achievable (ALARA) radiation dose.
Collapse
Affiliation(s)
- Lisan A Neefjes
- Department of Cardiology, Erasmus Medical Center, Room Hs 207, P.O. Box 2040, 3000 CA, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Soon K, Wong C. Coronary computed tomography angiography: a new wave of cardiac imaging. Intern Med J 2012; 42 Suppl 5:22-9. [DOI: 10.1111/j.1445-5994.2012.02901.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
26
|
Bischoff B, Bamberg F, Marcus R, Schwarz F, Becker HC, Becker A, Reiser M, Nikolaou K. Optimal timing for first-pass stress CT myocardial perfusion imaging. Int J Cardiovasc Imaging 2012; 29:435-42. [DOI: 10.1007/s10554-012-0080-y] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Accepted: 06/04/2012] [Indexed: 11/30/2022]
|
27
|
Image quality, contrast enhancement, and radiation dose of ECG-triggered high-pitch CT versus non-ECG-triggered standard-pitch CT of the thoracoabdominal aorta. AJR Am J Roentgenol 2012; 198:931-8. [PMID: 22451563 DOI: 10.2214/ajr.11.6921] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE We sought to compare image quality, contrast enhancement, and radiation dose in patients undergoing ECG-triggered high-pitch helical CT or non-ECG-synchronized helical CT of the thoracoabdominal aorta. MATERIALS AND METHODS We retrospectively assessed data from 101 consecutive patients (81 men, 20 women; mean age, 71 ± 11 [SD] years) undergoing clinically indicated CT angiography (CTA) of the thoracoabdominal aorta on a dual-source scanner using either the ECG-triggered high-pitch helical mode (group 1, n = 52) or non-ECG-synchronized standard-pitch helical mode (group 2, n = 49) during the arterial phase. Two independent readers assessed image quality, noise, and contrast enhancement throughout the thoracoabdominal aorta. Scanner-reported dose-length product values were used to estimate effective dose values. RESULTS Image quality at the root-proximal ascending level was higher in group 1 (mean ± SD, 2.81 ± 0.40) than in group 2 (1.22 ± 0.47; p < 0.0001), with similar quality for both groups noted at other levels. Group 1 scans displayed higher image noise at all levels. The groups received a similar volume of contrast material (p = 0.77), and similar percentages of cases with acceptable contrast enhancement (> 250 HU) were noted in the two groups. The estimated radiation burden was significantly lower in group 1 (mean ± SD, 5.4 ± 1.8 mSv) than in group 2 (14.4 ± 5.1 mSv; p < 0.0001). CONCLUSION Imaging of the thoracoabdominal aorta with ECG-triggered high-pitch CTA provides higher quality images of the aortic root and ascending aorta with sufficient contrast enhancement and decreased estimated radiation dose compared with non-ECG-synchronized standard-pitch helical CT.
Collapse
|
28
|
Hu XH, Zheng WL, Wang D, Xie SS, Wu R, Zhang SZ. Accuracy of high-pitch prospectively ECG-triggering CT coronary angiography for assessment of stenosis in 103 patients: comparison with invasive coronary angiography. Clin Radiol 2012; 67:1083-8. [PMID: 22613169 DOI: 10.1016/j.crad.2012.03.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2011] [Revised: 03/22/2012] [Accepted: 03/27/2012] [Indexed: 10/28/2022]
Abstract
AIM To investigate the accuracy of high-pitch prospectively electrocardiogram (ECG)-triggering low-dose, dual-source computed tomography (CT) coronary angiography for assessing coronary artery stenosis compared with conventional coronary angiography. MATERIALS AND METHODS One hundred and three patients undergoing high-pitch CT coronary angiography (CTCA) and conventional coronary angiography (CCA) within 30 days were enrolled. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of high-pitch CTCA for detecting >50 and >70% stenosis were evaluated using CCA as the reference standard on a per-segment, per-vessel, and per-patient basis. Two experienced radiologists independently rated high-pitch CTCA images for quality using a four-point scale (1 = excellent, 4 = non-diagnostic) on a per-segment basis. The effective dose was calculated by multiplying the conversion coefficient of 0.028 by the dose-length product. RESULTS The mean heart rate of patients was 57 ± 6 beats/min. For detecting >50% stenosis, the sensitivity, specificity, PPV, and NPV of high-pitch CTCA were 89, 97, 87, and 97% on a per-segment basis; 91, 92, 92, and 91% on a per-vessel basis; and 99, 85, 96, and 94% on a per-patient basis. For detecting >70% stenosis, the sensitivity, specificity, PPV, and NPV of high-pitch CTCA were 96, 98, 90, and 99% on a per-segment basis. Coronary segments were rated as diagnostic in 98.6% (1355/1375) of cases (score 1, 72.5%; score 2, 23.1%; score 3, 3%; score 4, 1.4%). The effective dose of high-pitch CTCA was 1.51 ± 0.31 mSv. CONCLUSION High-pitch prospectively ECG-triggering dual-source CTCA provides good image quality and high diagnostic accuracy with a 1.51 mSv radiation dose.
Collapse
Affiliation(s)
- X H Hu
- Department of Radiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, China
| | | | | | | | | | | |
Collapse
|
29
|
Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease. Eur Radiol 2012; 22:2057-66. [DOI: 10.1007/s00330-012-2479-1] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2012] [Revised: 03/19/2012] [Accepted: 03/27/2012] [Indexed: 10/28/2022]
|
30
|
Srichai MB, Lim RP, Donnino R, Mannelli L, Hiralal R, Avery R, Ho C, Babb JS, Jacobs JE. Low-dose, prospective triggered high-pitch spiral coronary computed tomography angiography: comparison with retrospective spiral technique. Acad Radiol 2012; 19:554-561. [PMID: 22366557 DOI: 10.1016/j.acra.2012.01.009] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2011] [Revised: 01/18/2012] [Accepted: 01/19/2012] [Indexed: 10/28/2022]
Abstract
RATIONALE AND OBJECTIVES Cardiac computed tomographic angiography algorithms emphasize radiation reduction while maintaining diagnostic image quality (IQ). The aim of this study was to evaluate IQ and interreader variability using prospective electrocardiographically triggered high-pitch spiral cardiac computed tomographic angiography (FLASH-CT) compared to retrospective electrocardiographic gating (RETRO-CT) for coronary artery disease evaluation in a patient population including overweight and obese individuals. MATERIALS AND METHODS Seventy patients (24 women; mean age, 60 years) matched for gender, age, body mass index (27.4 ± 5.5 kg/m(2)), and calcium score (184 ± 328) underwent cardiac computed tomographic angiography, 35 with FLASH-CT (Definition Flash) and 35 with RETRO-CT (Somatom Definition). Images were reconstructed using standard protocols and least motion phase for RETRO-CT acquisitions. Two independent, blinded readers evaluated the coronary arteries using an 18-segment model, grading IQ on a 5-point, Likert-type scale and coronary stenosis on a 5-point semiquantitative and binary scale. RESULTS Effective radiation dose (1.50 vs 17.3 mSv, P < .0001) and mean heart rate (58 vs 62 beats/min, P < .05) were significantly lower for FLASH-CT compared to RETRO-CT. Seven hundred forty segments (> 1.5 mm) were evaluated. There was no significant difference between FLASH-CT and RETRO-CT scans in overall per-segment IQ (3.11 ± 0.75 vs 3.10 ± 0.82, P = .94). FLASH-CT had noninferior IQ relative to RETRO-CT (95% confidence interval, -0.25 to 0.26). There was no significant difference in interreader variability in diagnosis between FLASH-CT and RETRO-CT for all coronary segments (77.5% vs 78.2%, P = .83). CONCLUSIONS FLASH-CT is an acceptable coronary computed tomographic angiographic method for reducing radiation dose without compromising IQ for a patient population including overweight and obese individuals.
Collapse
Affiliation(s)
- Monvadi B Srichai
- Department of Radiology, New York University, 550 First Avenue, New York, NY 10016, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Park EA, Lee W, Kim KW, Kim KG, Thomas A, Chung JW, Park JH. Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose. Int J Cardiovasc Imaging 2011; 28:1775-86. [PMID: 22187198 DOI: 10.1007/s10554-011-0004-2] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2011] [Accepted: 12/14/2011] [Indexed: 11/30/2022]
Abstract
To assess the image quality and radiation dose of low-dose dual-source CT (DSCT) coronary angiography reconstructed using iterative reconstruction in image space (IRIS), in comparison with routine-dose CT using filtered back projection (FBP). Eighty-one patients underwent low-dose coronary DSCT using IRIS with two protocols: (a)100 kVp and 200 mAs per rotation for body mass index (BMI) < 25 (group I), (b)100 kVp and 320 mAs for BMI ≥ 25 (II). For comparison, two sex-and BMI-matched groups using standard protocols with FBP were selected: (a)100 kVp and 320 mAs for BMI < 25 (III), (b)120 kVp and 320 mAs for BMI ≥ 25 (IV). Image noise, signal to noise ratio (SNR) and modulation transfer function (MTF) 50% were objectively calculated. Two blinded readers then subjectively graded the image quality. Radiation dose was also measured. Image noise tended to be lower in IRIS of low-dose protocols: 22.0 ± 4.5 for group I versus 24.8 ± 4.0 for III (P < 0.001); 20.9 ± 4.5 for II versus 21.6 ± 4.9 for IV (P = 0.6). SNR was better with IRIS: 25.8 ± 4.4 for I versus 22.7 ± 4.6 for III (P < 0.001); 24.6 ± 5.4 for II versus 18.7 ± 4.5 for IV (P < 0.001). No differences in MTF 50% or image quality scores were seen between each two groups (P > 0.05). Radiation reduction was 40% for I and 51% for II, compared to standard protocols. Compared with routine-dose CT using FBP, low-dose coronary angiography using IRIS provides significant radiation reduction without impairment to image quality.
Collapse
Affiliation(s)
- Eun-Ah Park
- Department of Radiology, Seoul National University Hospital, Seoul 110-744, Korea
| | | | | | | | | | | | | |
Collapse
|
32
|
Neefjes LA, Dharampal AS, Rossi A, Nieman K, Weustink AC, Dijkshoorn ML, Ten Kate GJR, Dedic A, Papadopoulou SL, van Straten M, Cademartiri F, Krestin GP, de Feyter PJ, Mollet NR. Image quality and radiation exposure using different low-dose scan protocols in dual-source CT coronary angiography: randomized study. Radiology 2011; 261:779-86. [PMID: 21969666 DOI: 10.1148/radiol.11110606] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To compare image quality, radiation dose, and their relationship with heart rate of computed tomographic (CT) coronary angiographic scan protocols by using a 128-section dual-source CT scanner. MATERIALS AND METHODS Institutional review board approved the study; all patients gave informed consent. Two hundred seventy-two patients (175 men, 97 women; mean ages, 58 and 59 years, respectively) referred for CT coronary angiography were categorized according to heart rate: less than 65 beats per minute (group A) and 65 beats per minute or greater (group B). Patients were randomized to undergo prospective high-pitch spiral scanning and narrow-window prospective sequential scanning in group A (n = 160) or wide-window prospective sequential scanning and retrospective spiral scanning in group B (n = 112). Image quality was graded (1 = nondiagnostic; 2 = artifacts present, diagnostic; 3 = no artifacts) and compared (Mann-Whitney and Student t tests). RESULTS In group A, mean image quality grade was significantly lower with high-pitch spiral versus sequential scanning (2.67 ± 0.38 [standard deviation] vs 2.86 ± 0.21; P < .001). In a subpopulation (heart rate, <55 beats per minute), mean image quality grade was similar (2.81 ± 0.30 vs 2.94 ± 0.08; P = .35). In group B, image quality grade was comparable between sequential and retrospective spiral scanning (2.81 ± 0.28 vs 2.80 ± 0.38; P = .54). Mean estimated radiation dose was significantly lower (high-pitch spiral vs sequential scanning) in group A (for 100 kV, 0.81 mSv ± 0.30 vs 2.74 mSv ± 1.14 [P < .001]; for 120 kV, 1.65 mSv ± 0.69 vs 4.21 mSv ± 1.20 [P < .001]) and in group B (sequential vs retrospective spiral scanning) (for 100 kV, 4.07 mSv ± 1.07 vs 5.54 mSv ± 1.76 [P = .02]; for 120 kV, 7.50 mSv ± 1.79 vs 9.83 mSv ± 3.49 [P = .1]). CONCLUSION A high-pitch spiral CT coronary angiographic protocol should be applied in patients with regular and low (<55 beats per minute) heart rates; a sequential protocol is preferred in all others.
Collapse
Affiliation(s)
- Lisan A Neefjes
- Department of Radiology, Erasmus Medical Center, Dr Molewaterplein 40, Room Hs 207, PO Box 2040, 3000 CA Rotterdam, the Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
|
34
|
Cardiovascular sources of systemic embolism: detection and characterization using multidetector CT and MR imaging. Int J Cardiovasc Imaging 2011; 27:727-44. [DOI: 10.1007/s10554-011-9878-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2011] [Accepted: 04/15/2011] [Indexed: 12/27/2022]
|
35
|
Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: study with an anthropomorphic and water phantom. Eur J Radiol 2011; 81:e699-703. [PMID: 21316888 DOI: 10.1016/j.ejrad.2011.01.078] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2010] [Revised: 01/15/2011] [Accepted: 01/17/2011] [Indexed: 11/23/2022]
Abstract
PURPOSE The aim of this study was to explore the relationship of scanning parameters (clinical protocols), reconstruction kernels and slice thickness with image quality and radiation dose in a DSCT. MATERIALS AND METHODS The chest of an anthropomorphic phantom was scanned on a DSCT scanner (Siemens Somatom Definition flash) using different clinical protocols, including single- and dual-energy modes. Four scan protocols were investigated: 1) single-source 120kV, 110mAs, 2) single-source 100kV, 180mAs, 3) high-pitch 120kV, 130mAs and 4) dual-energy with 100/Sn140kV, eff.mAs 89, 76. The automatic exposure control was switched off for all the scans and the CTDIvol selected was in between 7.12 and 7.37mGy. The raw data were reconstructed using the reconstruction kernels B31f, B80f and B70f, and slice thicknesses were 1.0mm and 5.0mm. Finally, the same parameters and procedures were used for the scanning of water phantom. Friedman test and Wilcoxon-Matched-Pair test were used for statistical analysis. RESULTS The DLP based on the given CTDIvol values showed significantly lower exposure for protocol 4, when compared to protocol 1 (percent difference 5.18%), protocol 2 (percent diff. 4.51%), and protocol 3 (percent diff. 8.81%). The highest change in Hounsfield Units was observed with dual-energy Sn140-kV (Hounsfield unit 15.18) compared to protocol 2 (24.35HU). The differences in noise between the different clinical protocol data sets were statistically significant [protocol 3 vs. dual-energy 100-kV (p<0.01) and protocol 3 vs. dual-energy Sn140-kV (p<0.01)]. The dual-energy Sn140-kV protocol shows the highest image noise (14.5HU for 5.0mm slice (B31f) and 162HU for 1.0mm slice (B70f) thickness). The difference between reconstruction kernel B31f and B80f images made using 5.0mm reconstruction thickness was statistically significant (p<0.0312) and 1.0mm slice thickness shows the significance of p<0.0312 between B31f and B70f reconstructions. In both cases, the lowest image noise was obtained from B31f reconstructed images. Again the slice thickness significantly affects image noise (p<0.03) and the noise was higher at 1.0mm compared to that at 5.0mm slice thickness. CONCLUSION The clinical protocol, reconstruction kernel, slice thickness and phantom diameter or the density of material it contains directly affects the image quality. Dual energy protocol shows the lowest dose-length-product compared to all other protocols examined, the fused image shows excellent image quality and the noise is same as that of single or high-pitch mode protocol images. Advanced CT technology improves image quality and considerably reduces radiation dose.
Collapse
|