Kazimierczak W, Kazimierczak N, Wilamowska J, Wojtowicz O, Nowak E, Serafin Z. Enhanced visualization in endoleak detection through iterative and AI-noise optimized spectral reconstructions. Sci Rep 2024; 14:3845. [PMID: 38360941 PMCID: PMC10869818 DOI: 10.1038/s41598-024-54502-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 02/13/2024] [Indexed: 02/17/2024] Open
Abstract
To assess the image quality parameters of dual-energy computed tomography angiography (DECTA) 40-, and 60 keV virtual monoenergetic images (VMIs) combined with deep learning-based image reconstruction model (DLM) and iterative reconstructions (IR). CT scans of 28 post EVAR patients were enrolled. The 60 s delayed phase of DECTA was evaluated. Objective [noise, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR)] and subjective (overall image quality and endoleak conspicuity - 3 blinded readers assessment) image quality analyses were performed. The following reconstructions were evaluated: VMI 40, 60 keV VMI; IR VMI 40, 60 keV; DLM VMI 40, 60 keV. The noise level of the DLM VMI images was approximately 50% lower than that of VMI reconstruction. The highest CNR and SNR values were measured in VMI DLM images. The mean CNR in endoleak in 40 keV was accounted for as 1.83 ± 1.2; 2.07 ± 2.02; 3.6 ± 3.26 in VMI, VMI IR, and VMI DLM, respectively. The DLM algorithm significantly reduced noise and increased lesion conspicuity, resulting in higher objective and subjective image quality compared to other reconstruction techniques. The application of DLM algorithms to low-energy VMIs significantly enhances the diagnostic value of DECTA in evaluating endoleaks. DLM reconstructions surpass traditional VMIs and IR in terms of image quality.
Collapse
Affiliation(s)
- Wojciech Kazimierczak
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland.
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009, Bydgoszcz, Poland.
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland.
| | - Natalia Kazimierczak
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009, Bydgoszcz, Poland
| | - Justyna Wilamowska
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland
| | - Olaf Wojtowicz
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland
| | - Ewa Nowak
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland
| | - Zbigniew Serafin
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland
| |
Collapse
|
2
|
Chen PA, Huang EP, Chen YC, Chuo CC, Huang ST, Wu MT. Can Low-Iodine, Low-Radiation-Dose CT Aortogram Reliably Detect Endoleak after Endovascular Aneurysm Repair of the Aorta? Diagnostics (Basel) 2023; 13:2228. [PMID: 37443622 PMCID: PMC10340752 DOI: 10.3390/diagnostics13132228] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 06/28/2023] [Accepted: 06/28/2023] [Indexed: 07/15/2023] Open
Abstract
OBJECTIVE Double-low CT aortography (DLCTA) is increasingly used in follow-up studies of aortic aneurysm after endovascular aneurysm repair (EVAR). However, whether DLCTA can reliably detect the presence of endoleak is not clear. METHODS From February 2014 to October 2019, patients who received EVAR, underwent CT surveillance, and had at least one standard CTA protocol (120 kVp, 400 mg I/kg) and one DLCTA (70-80 kVp, 200 mg I/kg) were included. The integrated findings of the standard CTA and sequential change were considered as the reference standard for the presence of endoleak. RESULTS In all, 36 patients received TEVAR and 24 patients received EVAR; 62 standard CTA and 167 DLCTA results were analyzed. There were 2 type I (3.3%) and 12 type II (20.0%) endoleaks in 14 patients (23.3%). The performance of DLCTA in the diagnosis of endoleak reached 100% accuracy compared to that of standard CTA in case of the correction of CT findings by an expert second reading. Compared to the standard CTA, DLCTA scan reduced the radiation dose by 71% and the iodine dose by 50%. CONCLUSIONS DLCTA with 70-80 kVp and 200 mg I/kg can reliably detect the presence of endoleak after TEVAR/EVAR.
Collapse
Affiliation(s)
- Po-An Chen
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 813, Taiwan; (P.-A.C.); (Y.-C.C.)
- Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan;
- Department of Radiology, Park One International Hospital, No. 100, Bo’ai 2nd Road, Kaohsiung 813, Taiwan
| | - Eric P. Huang
- Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan;
- Department of Radiology, New Taipei City Hospital, No. 3, Sec. 1, New Taipei Blvd., Sanchong Dist., New Taipei City 241, Taiwan
| | - Yi-Chun Chen
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 813, Taiwan; (P.-A.C.); (Y.-C.C.)
| | - Chiung-Chen Chuo
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 813, Taiwan; (P.-A.C.); (Y.-C.C.)
| | - Shu-Tin Huang
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 813, Taiwan; (P.-A.C.); (Y.-C.C.)
| | - Ming-Ting Wu
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 813, Taiwan; (P.-A.C.); (Y.-C.C.)
- Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan;
- Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
| |
Collapse
|
3
|
Safe Follow-Up after Endovascular Aortic Repair with Unenhanced MRI: The SAFEVAR Study. Diagnostics (Basel) 2022; 13:diagnostics13010020. [PMID: 36611311 PMCID: PMC9818075 DOI: 10.3390/diagnostics13010020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 12/05/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022] Open
Abstract
We aimed to investigate whether unenhanced magnetic resonance imaging (MRI) could represent a safe and highly sensitive tool for endoleak screening in patients treated with endovascular aneurysm repair (EVAR) using computed tomography angiography (CTA) as a reference standard. Patients who underwent CTA for EVAR follow-up at our institution were prospectively enrolled. All MRI examinations were performed with a 1.5 T unit. The true-FISP and HASTE sequences of the MRI scans were assessed for the presence of hyperintensity within the aneurysm sac outside the graft, whereas phase-contrast through-plane sequences were used for blood flow quantification. We included 45 patients, 5 (11%) of whom were female. The median age was 73 years (IQR 68−78 years). Among our patients, 19 (42%) were positive for endoleaks at CTA, of whom 13 (68%) had type II endoleaks and 6 (32%) had type I endoleaks. There were no significant differences in age, sex, aneurysm type, prosthesis type, or contrast-to-noise ratio between hyperintensity and thrombus between patients with and without endoleaks (p > 0.300). The combined evaluation of true-FISP and HASTE yielded 100% sensitivity (95% CI: 79−100%) and 19% specificity (95% CI: 7−40%). Patients with a positive CTA had a median thrombus flow of 0.06 L/min (IQR 0.03−0.23 L/min), significantly greater than that of patients with a negative CTA (p = 0.007). Setting a threshold at 0.01 L/min, our MRI protocol yielded 100% sensitivity, 56% specificity, and an AUC of 0.76 (95% CI 0.60−0.91). In conclusion, unenhanced MRI has perfect sensitivity for endoleak detection, although with subpar specificity that could be improved with phase-contrast flow analysis.
Collapse
|
4
|
Meurer F, Kopp F, Renz M, Harder FN, Leonhardt Y, Bippus R, Noël PB, Makowski MR, Sauter AP. Sparse-sampling computed tomography for detection of endoleak after endovascular aortic repair (EVAR). Eur J Radiol 2021; 142:109843. [PMID: 34274842 DOI: 10.1016/j.ejrad.2021.109843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 06/21/2021] [Accepted: 06/29/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES To evaluate sparse sampling computed tomography (SpSCT) for detection of endoleak after endovascular aortic repair (EVAR) at different dose levels in terms of subjective image criteria and diagnostic accuracy. METHODS Twenty clinically indicated computed tomography aortic angiography (CTA) scans were used to obtain simulated low-dose scans with 100%, 50%, 25%, 12.5% and 6.25% of the applicated clinical dose, resulting in five dose levels (DL). From full sampling (FS) data sets, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to generate simulated sparse sampling scans. All examinations were evaluated by four blinded radiologists regarding subjective image criteria and diagnostic performance. RESULTS Sensitivity was higher than 93% in 4-SpSCT at the 25% DL which is the same as with FS at full dose (100% DL). High accuracies and relative high AUC-values were obtained for 2- and 4-SpSCT down to the 12.5% DL, while for FS similar values were shown down to 25% DL only. Subjective image quality was significantly higher for 4-SpSCT compared to FS at each dose level. More than 90% of all cases were rated with a high or medium confidence for FS and 2-SpSCT at the 50% DL and for 4-SpSCT at the 25% DL. At DL 25% and 12.5%, more cases showed a high confidence using 2- and 4-SpSCT compared with FS. CONCLUSIONS Via SpSCT, a dose reduction down to a 25% dose level (mean effective dose of 1.49 mSv in the current study) for CTA is possible while maintaining high image quality and full diagnostic confidence.
Collapse
Affiliation(s)
- Felix Meurer
- Klinikum rechts der Isar, School of Medicine Technical University of Munich, Institute of Diagnostic and Interventional Radiology, Munich, Germany.
| | - Felix Kopp
- Klinikum rechts der Isar, School of Medicine Technical University of Munich, Institute of Diagnostic and Interventional Radiology, Munich, Germany
| | - Martin Renz
- Klinikum rechts der Isar, School of Medicine Technical University of Munich, Institute of Diagnostic and Interventional Radiology, Munich, Germany
| | - Felix N Harder
- Klinikum rechts der Isar, School of Medicine Technical University of Munich, Institute of Diagnostic and Interventional Radiology, Munich, Germany
| | - Yannik Leonhardt
- Klinikum rechts der Isar, School of Medicine Technical University of Munich, Institute of Diagnostic and Interventional Radiology, Munich, Germany
| | - Rolf Bippus
- Philips Technologie GmbH Innovative Technologies, Research Laboratories, Hamburg, Germany
| | - Peter B Noël
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
| | - Markus R Makowski
- Klinikum rechts der Isar, School of Medicine Technical University of Munich, Institute of Diagnostic and Interventional Radiology, Munich, Germany
| | - Andreas P Sauter
- Klinikum rechts der Isar, School of Medicine Technical University of Munich, Institute of Diagnostic and Interventional Radiology, Munich, Germany
| |
Collapse
|
5
|
Kim SH, Litt HI. Surveillance Imaging following Endovascular Aneurysm Repair: State of the Art. Semin Intervent Radiol 2020; 37:356-364. [PMID: 33041481 DOI: 10.1055/s-0040-1715882] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Endovascular aneurysmal repair (EVAR) has become a prominent modality for the treatment of abdominal aortic aneurysm. Surveillance imaging is important for the detection of device-related complications, which include endoleak, structural abnormalities, and infection. Currently used modalities include ultrasound, X-ray, computed tomography, magnetic resonance imaging, and angiography. Understanding the advantages and drawbacks of each modality, as well available guidelines, can guide selection of the appropriate technique for individual patients. We review complications following EVAR and advances in surveillance imaging modalities.
Collapse
Affiliation(s)
- Stephanie H Kim
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Harold I Litt
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
6
|
Villegas L, Cahill AM, Meyers K. Pediatric Renovascular Hypertension: Manifestations and Management. Indian Pediatr 2020. [DOI: 10.1007/s13312-020-1820-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
7
|
Contemporary imaging methods for the follow-up after endovascular abdominal aneurysm repair: a review. Wideochir Inne Tech Maloinwazyjne 2019; 14:1-11. [PMID: 30766622 PMCID: PMC6372875 DOI: 10.5114/wiitm.2018.78973] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 08/21/2018] [Indexed: 11/23/2022] Open
Abstract
Abdominal aortic aneurysm (AAA) is defined as a localized enlargement of the aortic cross-section where the diameter is greater than 3 cm or more than 50% larger than the diameter in a normal segment. The most important complication of AAA is rupture, which, if untreated, results in mortality rates of up to 90%. Conventional open surgical repair is associated with significant 30-day mortality. Endovascular aneurysm repair (EVAR) is a significantly less invasive procedure; it is related to a lower early mortality rate and a lower number of perioperative complications. Although EVAR is a minimally invasive technique, lifelong follow-up imaging is necessary due to possible late complications including endoleak, recurrent aneurysm formation, graft infection, migration, kinking and thrombosis. The total rate of complications after EVAR is estimated at approximately 30%, and the rate of complications that require intervention is 2–3%. Early detection and progression analysis of such situations is crucial for proper intervention.
Collapse
|
8
|
Michalska M, Kazimierczak W, Leszczyński W, Nadolska K, Bryl Ł. Contemporary follow-up imaging after endovascular repair of lower extremity atherosclerotic lesions. Pol J Radiol 2018; 83:e634-e642. [PMID: 30800203 PMCID: PMC6384408 DOI: 10.5114/pjr.2018.80348] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Accepted: 11/22/2018] [Indexed: 12/22/2022] Open
Abstract
Atherosclerotic disease is currently one of the most important problems of modern medicine because it is a leading cause of increased morbidity, morbidity and mortality, and disability in the Western World. Atherosclerosis of the lower limbs (peripheral arterial disease - PAD) significantly affects the quality of life and in a considerable proportion of patients is a cause of disability. Radical treatment of PAD, both surgical and endovascular, aims at revascularisation of ischaemic tissues distal to obstructed arteries. Surveillance imaging is an important part of patient management after endovascular repair of PAD. Apart from availability and contraindications, challenges of imaging include calcifications, flow dynamics, and stent-related artefacts. The aim of this paper was to review the current literature on imaging methods for follow-up after endovascular repair of atherosclerotic lesions, with special attention paid to novel techniques. As a non-invasive modality, ultrasound is still the first-line examination, but computed tomography angiography remains a current state-of-the art technique for follow-up. However, since current imaging recommendations seem not to adhere to contemporary imaging possibilities, more attention should be paid to recent improvements in magnetic resonance angiography technology.
Collapse
|
9
|
Böning G, Rotzinger RA, Kahn JF, Freyhardt P, Renz DM, Maurer M, Streitparth F. Tailored CT angiography in follow-up after endovascular aneurysm repair (EVAR): combined dose reduction techniques. Acta Radiol 2018; 59:1316-1325. [PMID: 29430936 DOI: 10.1177/0284185118756952] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Background Endovascular aneurysm repair (EVAR) requires lifelong surveillance by computed tomography angiography (CTA). This is attended by a substantial accumulation of radiation exposure. Iterative reconstruction (IR) has been introduced to approach dose reduction. Purpose To evaluate adaptive statistical iterative reconstruction (ASIR) at different levels of tube voltage concerning image quality and dose reduction potential in follow-up post EVAR. Material and Methods One hundred CTAs in 67 patients with EVAR were examined using five protocols: protocol A (n = 40) as biphasic standard using filtered back projection (FBP) at 120 kV; protocols B (n = 40), C (n = 10), and D1 (n = 5) biphasic using ASIR at 120, 100, and 80 kV, respectively; and protocol D2 (n = 5) with a monophasic splitbolus ASIR protocol at 80 kV. Image quality was assessed quantitatively and qualitatively. Applied doses were determined. Results Applied doses in ASIR protocols were significantly lower than FBP standard (up to 75%). Compared to protocol A, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) (e.g. arterial CNR intra-/extra-stent lumen: A = 35.4 ± 13.5, B = 34.2 ± 10.0, C = 29.6 ± 6.8, D1 = 32.1 ± 6.3, D2 = 40.8 ± 23.1) in protocol B were equal and in protocols C and D equal to partially inferior, however not decisive for diagnostic quality. Subjective image quality ratings in all protocols were good to excellent without impairments of diagnostic confidence (A-D2: 5), with high inter-rater agreement (60-100%). Conclusion ASIR contributes to significant dose reduction without decisive impairments of image quality and diagnostic confidence. We recommend an adapted follow-up introducing ASIR and combined low-kV in the long-term surveillance after EVAR.
Collapse
Affiliation(s)
- Georg Böning
- 1 Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Roman A Rotzinger
- 1 Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Johannes F Kahn
- 1 Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Patrick Freyhardt
- 1 Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Diane M Renz
- 2 Department of Radiology, Jena University Hospital, Jena, Germany
| | - Martin Maurer
- 3 Department of Radiology, Inselspital Bern, Bern, Switzerland
| | - Florian Streitparth
- 1 Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
10
|
Louis R, Levy-Erez D, Cahill AM, Meyers KE. Imaging studies in pediatric fibromuscular dysplasia (FMD): a single-center experience. Pediatr Nephrol 2018; 33:1593-1599. [PMID: 29869115 PMCID: PMC6082421 DOI: 10.1007/s00467-018-3983-6] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/08/2018] [Accepted: 05/09/2018] [Indexed: 01/01/2023]
Abstract
BACKGROUND Fibromuscular dysplasia (FMD) is a non-inflammatory vascular disease that in children unlike in adults shows no sex predilection. FMD is often underdiagnosed, and its pathophysiology is unclear. Delayed diagnosis may lead to refractory hypertension and decreases the chance of successful treatment. Doppler ultrasound (US), magnetic resonance angiography (MRA), computed tomography angiography (CTA), and catheter-based angiography (angiography) are currently used to help make a clinicoradiological diagnosis of FMD. The main aim of the study was to compare the efficacy of imaging modalities which can allow for earlier and improved detection. Furthermore, an anatomical mapping of the location of lesions can help determine the best treatment modalities. METHODS All patients with non-syndromic non-inflammatory renovascular hypertension were recruited from the Nephrology Department at the Children's Hospital of Philadelphia (CHOP) and enrolled in the U.S. FMD Registry maintained at the University of Michigan. Clinical presentation and imaging findings on US, CT, and MRI of children diagnosed with FMD were evaluated. RESULTS Mean age at diagnosis was 7 ± 4.9 years (4 months-17 years). Family history of hypertension (HTN) (52%), FMD (8.7%), Caucasian (60%), headache (48%), and HTN (80%) were the most prevalent symptom and sign at presentation. Bruits were 100% specific for renal artery stenosis (RAS) diagnosis but were heard in the minority of patients (3 patients, 12%). FMD was mainly unifocal within a single site (68%) or multiple sites (28%) and involved the main or first order renal branch in about 68% of children. Isolated distal lesions beyond the second order branches were found in about 25% of children. US imaging was significantly less sensitive than angiography (28%, p = 0.003). MRA had a better sensitivity (62.5%, p = 0.3) than US. Overall, CTA had the best sensitivity (84.2%, p = 0.4) compared to angiography; however, only angiography showed distal vessel disease. CONCLUSIONS Limitations of the study include the sample size and biases-only patients diagnosed with FMD were included in this study and most patients were referred to a pediatric nephrologist for unexplained hypertension. Angiography should be performed as part of the initial work-up of any child suspected of having renovascular FMD, regardless of the findings seen on US, MRA, or CTA.
Collapse
Affiliation(s)
- Robert Louis
- Division of Nephrology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, USA
- University of Pennsylvania, Philadelphia, PA, USA
| | - Daniella Levy-Erez
- Division of Nephrology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, USA.
- University of Pennsylvania, Philadelphia, PA, USA.
| | - Anne Marie Cahill
- University of Pennsylvania, Philadelphia, PA, USA
- Interventional Radiology, Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Kevin E Meyers
- Division of Nephrology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, USA
- University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
11
|
Hallett RL, Ullery BW, Fleischmann D. Abdominal aortic aneurysms: pre- and post-procedural imaging. Abdom Radiol (NY) 2018; 43:1044-1066. [PMID: 29460048 DOI: 10.1007/s00261-018-1520-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Abdominal aortic aneurysm (AAA) is a relatively common, potentially life-threatening disorder. Rupture of AAA is potentially catastrophic with high mortality. Intervention for AAA is indicated when the aneurysm reaches 5.0-5.5 cm or more, when symptomatic, or when increasing in size > 10 mm/year. AAA can be accurately assessed by cross-sectional imaging including computed tomography angiography and magnetic resonance angiography. Current options for intervention in AAA patients include open surgery and endovascular aneurysm repair (EVAR), with EVAR becoming more prevalent over time. Cross-sectional imaging plays a crucial role in AAA surveillance, pre-procedural assessment, and post-EVAR management. This paper will discuss the current role of imaging in the assessment of AAA patients prior to intervention, in evaluation of procedural complications, and in long-term follow-up of EVAR patients.
Collapse
Affiliation(s)
- Richard L Hallett
- Department of Radiology, Cardiovascular Imaging Section, Stanford University Hospital and Clinics, 300 Pasteur Drive, Grant Building, S-072, Stanford, CA, 94305, USA.
- St. Vincent Heart Center of Indiana, Indianapolis, IN, USA.
- Northwest Radiology Network, Indianapolis, IN, USA.
| | - Brant W Ullery
- Department of Cardiovascular Surgery, Providence Heart and Vascular Institute, Portland, OR, USA
| | - Dominik Fleischmann
- Department of Radiology, Cardiovascular Imaging Section, Stanford University Hospital and Clinics, 300 Pasteur Drive, Grant Building, S-072, Stanford, CA, 94305, USA
| |
Collapse
|
12
|
Daye D, Walker TG. Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management. Cardiovasc Diagn Ther 2018; 8:S138-S156. [PMID: 29850426 DOI: 10.21037/cdt.2017.09.17] [Citation(s) in RCA: 142] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
In recent decades, endovascular aneurysm repair or endovascular aortic repair (EVAR) has become an acceptable alternative to open surgery for the treatment of thoracic and abdominal aortic aneurysms and other aortic pathologies such as the acute aortic syndromes (e.g., penetrating aortic ulcer, intramural hematoma, dissection). Available data suggest that endovascular repair is associated with lower perioperative 30-day all-cause mortality as well as a significant reduction in perioperative morbidity when compared to open surgery. Additionally, EVAR leads to decreased blood loss, eliminates the need for cross-clamping the aorta and has shorter recovery periods than traditional surgery. It is currently the preferred mode of treatment of thoracic and abdominal aortic aneurysms in a subset of patients who meet certain anatomic criteria conducive to endovascular repair. The main disadvantage of EVAR procedures is the high rate of post-procedural complications that often require secondary re-intervention. As a result, most authorities recommend lifelong imaging surveillance following repair. Available surveillance modalities include conventional radiography, computed tomography, magnetic resonance angiography, ultrasonography, nuclear imaging and conventional angiography, with computed tomography currently considered to be the gold standard for surveillance by most experts. Following endovascular abdominal aortic aneurysm (AAA) repair, the rate of complications is estimated to range between 16% and 30%. The complication rate is higher following thoracic EVAR (TEVAR) and is estimated to be as high as 38%. Common complications include both those related to the endograft device and systemic complications. Device-related complications include endoleaks, endograft migration or collapse, kinking and/or stenosis of an endograft limb and graft infection. Post-procedural systemic complications include end-organ ischemia, cerebrovascular and cardiovascular events and post-implantation syndrome. Secondary re-interventions are required in approximately 19% to 24% of cases following endovascular abdominal and thoracic aortic aneurysm repair respectively. Typically, most secondary reinterventions involve the use of percutaneous techniques such as placement of cuff extension devices, additional endograft components or stents, enhancement of endograft fixation, treatment of certain endoleaks using various embolization techniques and embolic agents and thrombolysis of occluded endograft components. Less commonly, surgical conversion and/or open surgical modification are required. In this article, we provide an overview of the most common complications that may occur following endovascular repair of thoracic and AAAs. We also summarize the current surveillance recommendations for detecting and evaluating these complications and discuss various current secondary re-intervention approaches that may typically be employed for treatment.
Collapse
Affiliation(s)
- Dania Daye
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - T Gregory Walker
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
13
|
Hajdu SD, Daniel RT, Meuli RA, Zerlauth JB, Dunet V. Impact of model-based iterative reconstruction (MBIR) on image quality in cerebral CT angiography before and after intracranial aneurysm treatment. Eur J Radiol 2018; 102:109-114. [PMID: 29685523 DOI: 10.1016/j.ejrad.2018.03.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Revised: 03/04/2018] [Accepted: 03/05/2018] [Indexed: 12/25/2022]
Abstract
PURPOSE To subjectively and objectively assess the impact of model-based iterative reconstruction(MBIR) on image quality in cerebral computed tomography angiography compared to adaptive statistical iterative reconstruction (ASIR). METHODS 107 patients (mean age: 58 ± 14 years) were included prior to (n = 38) and after (n = 69) intracranial aneurysm treatment. Images were acquired using a routine protocol and reconstructed with MBIR and ASIR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios in the internal carotid and middle cerebral arteries were compared between MBIR and ASIR using the Wilcoxon signed-rank test. Additionally, two neuroradiologists subjectively assessed noise, artefacts, vessel sharpness and overall quality using a semi-quantitative assessment scale. RESULTS Objective assessment revealed that MBIR reduced noise (p < 0.0001) and additionally improved SNR (p < 0.0001) and CNR (p < 0.0001) compared to ASIR in untreated and treated patients. Subjective assessment revealed that in untreated patients, MBIR improved noise reduction, artefacts, vessel sharpness and overall quality relative to ASIR (p < 0.0001). In the treated groups, noise and vessel sharpness were improved (p < 0.0001) with no change in artefacts on images reconstructed with MBIR compared to ASIR. CONCLUSION MBIR significantly improves noise, SNR, CNR and vessel sharpness in untreated and treated patients with intracranial aneurysms. MBIR does not reduce artefacts generated by metallic devices following intracranial aneurysm treatment.
Collapse
Affiliation(s)
- Steven David Hajdu
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland.
| | - Roy Thomas Daniel
- Department of Neurosurgery, Lausanne University Hospital, Lausanne, Switzerland
| | - Reto Antoine Meuli
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Jean-Baptiste Zerlauth
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Vincent Dunet
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| |
Collapse
|
14
|
Boos J, Raptopoulos V, Brook A, Brook OR. Split-bolus intravenous contrast material injection vs. single-bolus injection in patients following endovascular abdominal aortic repair (EVAR). Abdom Radiol (NY) 2017; 42:2551-2561. [PMID: 28447108 DOI: 10.1007/s00261-017-1154-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE To investigate the feasibility and accuracy of a split-bolus contrast injection CTA (SB-CTA) compared to a single-bolus injection CTA (SI-CTA) protocol of post-EVAR patients. MATERIALS AND METHODS In this IRB-approved study, patients who underwent SB-CTA and SI-CTA after EVAR were evaluated. Attenuation and contrast-to-noise ratio (CNR) of vessels and parenchymal organs were assessed. Subjective enhancement of vessels, quality of 3D reconstructions, and enhancement phase of parenchymal organs were assessed by two independent readers. Endoleak visibility and incidental findings were evaluated. RESULTS Fifty-six patients with SB-CTA and SI-CTA at two different time points after EVAR were included in the study (112 imaging studies, mean age 75 ± 9 years). There was no difference in attenuation and CNR for aorta between SB-CTA and SI-CTA (310 ± 87 vs. 311 ± 80 HU, p = 0.88; 31.1 ± 12.6 vs. 29.0 ± 12.2, p = 0.20), although both were improved in the venous structures and parenchymal organs with SB-CTA (portal vein: 149 ± 33 vs. 88 ± 32 HU, 11.6 ± 5.6 vs. 4.3 ± 3.4; liver: 91 ± 19 vs. 68 ± 20 HU, 4.4 ± 2.8 vs. 2.1 ± 2.0; pancreas: 108 ± 27 vs. 82 ± 23 HU, 6.4 ± 3.1 vs. 3.6 ± 2.4; p < 0.0001). Subjectively, enhancement of veins, liver, spleen, bowel, and kidneys was improved (p < 0.001), while there was no difference for the aorta (p = 0.46) and 3D reconstructions (p = 0.58). None of the 18/56 (32.1%) endoleaks was missed with the SB-CTA. More incidental findings were detected with SB-CTA (158/56) compared to SI-CTA (135/56), p < 0.001. SB-CTA was able to adequately characterize 7/15 (47%) of the findings that needed further evaluation in SI-CTA. 4/15 (26%) incidental findings that were missed with SI-CTA but seen with SB-CTA required further evaluation. CONCLUSION Split-bolus injection CTA in the follow-up of EVAR patients allows reliable visualization of endoleaks with improved subjective and objective image quality.
Collapse
Affiliation(s)
- Johannes Boos
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, Boston, MA, 02215, USA
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, Moorenstraße 5, 40225, Dusseldorf, Germany
| | - Vassilios Raptopoulos
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, Boston, MA, 02215, USA
| | - Alexander Brook
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, Boston, MA, 02215, USA
| | - Olga R Brook
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, Boston, MA, 02215, USA.
| |
Collapse
|
15
|
Nassiri MA, Rouleau M, Després P. CT dose reduction: approaches, strategies and results from a province-wide program in Quebec. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2016; 36:346-362. [PMID: 27270762 DOI: 10.1088/0952-4746/36/2/346] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Many studies have shown a statistically significant increase of life-time risk of radiation-induced cancer from CT examinations. In this context, in Canada, the Quebec's provincial clinical center of expertise in radiation safety (CECR) has led a province-wide tour of 180 CT installations in order to: (i) evaluate the technical and functional performance of CT scanners, (ii) evaluate and improve radiation safety practices and (iii) initiate, with local teams, a CT dose optimization process. The CT tour consisted of a two day visit of CT installations by a CECR multidisciplinary team of medical physicists, engineers and medical imaging technologists (MITs) carried out in close collaboration with local teams composed of MITs, radiologists, physicists, engineers and managers. The CECR has evaluated 112 CT scanners since 2011. Optimization of CT protocols was performed in all centers visited. The average dose reduction obtained from optimization was [Formula: see text], [Formula: see text] and [Formula: see text] for adult head, thorax and abdomen-pelvis, respectively. The main recommendations often made by the CECR experts were: (1) the implementation of low-dose protocols for the follow-up of pulmonary nodules and for renal calculi, (2) the compliance to the prescribed scan range as defined by local guidelines, (3) the correct positioning of patients and (4) the use of bismuth shielding to reduce the dose to radiosensitive organs. The CECR approach to optimize CT doses to patients is based on the active participation of local stakeholders and takes into account the performance of CT scanners. The clinical requirements as expressed by radiologists remain at the core of the optimization process.
Collapse
Affiliation(s)
- Moulay Ali Nassiri
- Centre d'expertise clinique en radioprotection (CECR), Sherbrooke (Québec), Canada. Centre intégré universitaire de santé et de services sociaux de l'Estrie-Centre hospitalier universitaire de Sherbrooke (Québec), Canada
| | | | | |
Collapse
|
16
|
Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom. Pediatr Radiol 2016; 46:303-15. [PMID: 26546568 DOI: 10.1007/s00247-015-3486-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Revised: 08/10/2015] [Accepted: 10/19/2015] [Indexed: 12/29/2022]
Abstract
BACKGROUND CT of pediatric phantoms can provide useful guidance to the optimization of knowledge-based iterative reconstruction CT. OBJECTIVE To compare radiation dose and image quality of CT images obtained at different radiation doses reconstructed with knowledge-based iterative reconstruction, hybrid iterative reconstruction and filtered back-projection. MATERIALS AND METHODS We scanned a 5-year anthropomorphic phantom at seven levels of radiation. We then reconstructed CT data with knowledge-based iterative reconstruction (iterative model reconstruction [IMR] levels 1, 2 and 3; Philips Healthcare, Andover, MA), hybrid iterative reconstruction (iDose(4), levels 3 and 7; Philips Healthcare, Andover, MA) and filtered back-projection. The noise, signal-to-noise ratio and contrast-to-noise ratio were calculated. We evaluated low-contrast resolutions and detectability by low-contrast targets and subjective and objective spatial resolutions by the line pairs and wire. RESULTS With radiation at 100 peak kVp and 100 mAs (3.64 mSv), the relative doses ranged from 5% (0.19 mSv) to 150% (5.46 mSv). Lower noise and higher signal-to-noise, contrast-to-noise and objective spatial resolution were generally achieved in ascending order of filtered back-projection, iDose(4) levels 3 and 7, and IMR levels 1, 2 and 3, at all radiation dose levels. Compared with filtered back-projection at 100% dose, similar noise levels were obtained on IMR level 2 images at 24% dose and iDose(4) level 3 images at 50% dose, respectively. Regarding low-contrast resolution, low-contrast detectability and objective spatial resolution, IMR level 2 images at 24% dose showed comparable image quality with filtered back-projection at 100% dose. Subjective spatial resolution was not greatly affected by reconstruction algorithm. CONCLUSION Reduced-dose IMR obtained at 0.92 mSv (24%) showed similar image quality to routine-dose filtered back-projection obtained at 3.64 mSv (100%), and half-dose iDose(4) obtained at 1.81 mSv.
Collapse
|
17
|
Diagnostic imaging methods applied in long-term surveillance after EVAR. Will computed tomography angiography be replaced by other methods? ADVANCES IN INTERVENTIONAL CARDIOLOGY 2016; 12:6-12. [PMID: 26966443 PMCID: PMC4777700 DOI: 10.5114/pwki.2016.56943] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2015] [Accepted: 05/05/2015] [Indexed: 11/23/2022] Open
Abstract
Endovascular implantation of a stent graft in the abdominal aorta (endovascular aneurysm repair – EVAR) is a widely accepted alternative to open surgery in treatment of abdominal aortic aneurysms. Although EVAR is connected with a significant reduction in the risk of peri- and post-operative complications, it does not eliminate them totally. Long-term surveillance of post-EVAR patients is aimed at early detection of and fast reaction to a group of complications called endovascular leaks. Currently, the gold standard in leak diagnostics is computed tomography angiography (CTA). The other methods are ultrasonography, magnetic resonance (MR) angiography, intra-aneurysm sac pressure measurement, X-ray, and digital subtraction angiography (DSA). Despite many analyses based on long-term research, emphasising the high value and competitiveness of less invasive tests such as US or X-ray compared to CTA, it is still difficult for them to win the trust and acceptance of clinicians. The persisting view is that computed tomography is the test that finally resolves any inaccuracies. Consequently, a patient with a number of concurrent diseases is subject to absurdly high radiation exposure and effects of a radiocontrast agent within a short time. It is therefore logical to acknowledge that the EVAR-related risk is catching up with the open surgery risk, while the endovascular procedure is much more costly. Nevertheless, the status of CTA as the gold standard ultimately seems to be unthreatened. This paper presents a description of the diagnostic imaging tests that make it possible to detect any vascular leaks and to develop strategies for therapeutic processes.
Collapse
|
18
|
|
19
|
Non–Electrocardiogram-Triggered 70-kVp High-Pitch Computed Tomography Angiography of the Whole Aorta With Iterative Reconstruction. J Comput Assist Tomogr 2016; 40:109-17. [DOI: 10.1097/rct.0000000000000329] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
20
|
Seyal AR, Arslanoglu A, Abboud SF, Sahin A, Horowitz JM, Yaghmai V. CT of the Abdomen with Reduced Tube Voltage in Adults: A Practical Approach. Radiographics 2015; 35:1922-39. [PMID: 26473536 DOI: 10.1148/rg.2015150048] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Recent innovations in computed tomographic (CT) hardware and software have allowed implementation of low tube voltage imaging into everyday CT scanning protocols in adults. CT at a low tube voltage setting has many benefits, including (a) radiation dose reduction, which is crucial in young patients and those with chronic medical conditions undergoing serial CT examinations for disease management; and (b) higher contrast enhancement. For the latter, increased attenuation of iodinated contrast material improves the evaluation of hypervascular lesions, vascular structures, intestinal mucosa in patients with bowel disease, and CT urographic images. Additionally, the higher contrast enhancement may provide diagnostic images in patients with renal dysfunction receiving a reduced contrast material load and in patients with suboptimal peripheral intravenous access who require a lower contrast material injection rate. One limitation is that noisier images affect image quality at a low tube voltage setting. The development of denoising algorithms such as iterative reconstruction has made it possible to perform CT at a low tube voltage setting without compromising diagnostic confidence. Other potential pitfalls of low tube voltage CT include (a) photon starvation artifact in larger patients, (b) accentuation of streak artifacts, and (c) alteration of the CT attenuation value, which may affect evaluation of lesions on the basis of conventional enhancement thresholds. CT of the abdomen with a low tube voltage setting is an excellent radiation reduction technique when properly applied to imaging of select patients in the appropriate clinical setting.
Collapse
Affiliation(s)
- Adeel R Seyal
- From the Department of Radiology, Northwestern University-Feinberg School of Medicine, 676 N Saint Clair St, Suite 800, Chicago, IL 60611
| | - Atilla Arslanoglu
- From the Department of Radiology, Northwestern University-Feinberg School of Medicine, 676 N Saint Clair St, Suite 800, Chicago, IL 60611
| | - Samir F Abboud
- From the Department of Radiology, Northwestern University-Feinberg School of Medicine, 676 N Saint Clair St, Suite 800, Chicago, IL 60611
| | - Azize Sahin
- From the Department of Radiology, Northwestern University-Feinberg School of Medicine, 676 N Saint Clair St, Suite 800, Chicago, IL 60611
| | - Jeanne M Horowitz
- From the Department of Radiology, Northwestern University-Feinberg School of Medicine, 676 N Saint Clair St, Suite 800, Chicago, IL 60611
| | - Vahid Yaghmai
- From the Department of Radiology, Northwestern University-Feinberg School of Medicine, 676 N Saint Clair St, Suite 800, Chicago, IL 60611
| |
Collapse
|
21
|
Abstract
There is a significant risk of complication following endovascular abdominal repair (EVAR), including endoleak, graft translocation, thrombosis, and infection. Surveillance imaging is important for detecting EVAR complication. Surveillance modalities include conventional X-ray, computed tomography, magnetic resonance imaging, ultrasound, and conventional angiography, with inherent advantages and drawbacks to each modality. The authors present common complications following EVAR, and recent advances in the key modalities for surveillance.
Collapse
Affiliation(s)
- Nirnimesh Pandey
- Department of Radiology, Division of Interventional Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Harold I Litt
- Department of Radiology, Cardiovascular Imaging Section, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
22
|
Nicola R, Shaqdan KW, Aran S, Singh AK, Abujudeh HH. Detecting Aortic Graft Complications: A Spectrum of Computed Tomography Findings. Curr Probl Diagn Radiol 2015; 45:330-9. [PMID: 26321311 DOI: 10.1067/j.cpradiol.2015.07.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Revised: 07/27/2015] [Accepted: 07/28/2015] [Indexed: 11/22/2022]
Abstract
Endovascular aneurysm repair (EVAR) is a successful technique as well as an excellent alternative to the surgical management of abdominal aortic aneurysms. EVAR has improved the mortality and morbidity of many patients who would have otherwise suffered greatly from the consequences of abdominal aortic aneurysms. However, EVAR is not without complications. Some complications require lifelong surveillance, whereas others may necessitate immediate surgical intervention. We discuss the various modalities available for the surveillance as well as the common complications that can be seen on computed tomography.
Collapse
Affiliation(s)
- Refky Nicola
- Division of Emergency Imaging, University of Rochester Medical Center, Rochester, NY
| | - Khalid W Shaqdan
- Division of Emergency Imaging, Massachusetts General Hospital, Boston, MA
| | - Shima Aran
- Division of Emergency Imaging, Massachusetts General Hospital, Boston, MA
| | - Ajay K Singh
- Division of Emergency Imaging, Massachusetts General Hospital, Boston, MA
| | - Hani H Abujudeh
- Division of Emergency Imaging, Massachusetts General Hospital, Boston, MA.
| |
Collapse
|
23
|
Improving head and neck CTA with hybrid and model-based iterative reconstruction techniques. Clin Radiol 2015; 70:1252-9. [PMID: 26227475 DOI: 10.1016/j.crad.2015.06.095] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Revised: 06/09/2015] [Accepted: 06/25/2015] [Indexed: 11/23/2022]
Abstract
AIM To compare image quality of head and neck computed tomography angiography (CTA) reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) and model-based iterative reconstruction (MIR) algorithms. MATERIALS AND METHODS The raw data of 34 studies were simultaneously reconstructed with FBP, HIR (iDose(4), Philips Healthcare, Best, the Netherlands), and with a prototype version of a MIR algorithm (IMR, Philips Healthcare). Objective (contrast-to-noise ratio [CNR], vascular contrast, automatic vessel analysis [AVA], stenosis grade) and subjective image quality (ranking at level of the circle of Willis, carotid bifurcation, and shoulder) of the five reconstructions were compared using repeated-measures analysis of variance (ANOVA) and post-hoc analysis. RESULTS Vascular contrast was significantly higher in both the circle of Willis and carotid bifurcation with both levels of MIR compared to the other reconstruction methods (all p<0.0001). The CNR was highest for high MIR, followed by low MIR, high HIR, mid HIR and FBP (p<0.001 except low MIR versus high HIR; p>0.33). AVA showed most complete carotids in both MIR-levels, followed by high HIR (p>0.08), mid HIR (p<0.023) and FBP (p<0.010), vertebral arteries completeness was similar (p=0.40 and p=0.06). Stenosis grade showed no significant differences (p=0.16). High HIR showed the best subjective image quality at the circle of Willis and carotid bifurcation level, followed by mid HIR. At shoulder level, low MIR and high HIR were ranked best, followed by high MIR. CONCLUSION Objectively, MIR significantly improved the overall image quality, reduced image noise, and improved automated vessel analysis, whereas FBP showed the lowest objective image quality. Subjectively, the highest level of HIR was considered superior at the level of the circle of Willis and the carotid bifurcation, and along with the lowest level of MIR for the origins of the neck arteries at shoulder level.
Collapse
|
24
|
Vardhanabhuti V, James J, Nensey R, Hyde C, Roobottom C. Model-based iterative reconstruction in low-dose CT colonography-feasibility study in 65 patients for symptomatic investigation. Acad Radiol 2015; 22:563-71. [PMID: 25683499 DOI: 10.1016/j.acra.2014.12.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 12/17/2014] [Accepted: 12/18/2014] [Indexed: 12/29/2022]
Abstract
RATIONALE AND OBJECTIVES To compare image quality on computed tomographic colonography (CTC) acquired at standard dose (STD) and low dose (LD) using filtered-back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) techniques. MATERIALS AND METHODS A total of 65 symptomatic patients were prospectively enrolled for the study and underwent STD and LD CTC with filtered-back projection, adaptive statistical iterative reconstruction, and MBIR to allow direct per-patient comparison. Objective image noise, subjective image analyses, and polyp detection were assessed. RESULTS Objective image noise analysis demonstrates significant noise reduction using MBIR technique (P < .05) despite being acquired at lower doses. Subjective image analyses were superior for LD MBIR in all parameters except visibility of extracolonic lesions (two-dimensional) and visibility of colonic wall (three-dimensional) where there were no significant differences. There was no significant difference in polyp detection rates (P > .05). Doses: LD (dose-length product, 257.7), STD (dose-length product, 483.6). CONCLUSIONS LD MBIR CTC objectively shows improved image noise using parameters in our study. Subjectively, image quality is maintained. Polyp detection shows no significant difference but because of small numbers needs further validation. Average dose reduction of 47% can be achieved. This study confirms feasibility of using MBIR in this context of CTC in symptomatic population.
Collapse
|
25
|
Hertault A, Maurel B, Pontana F, Martin-Gonzalez T, Spear R, Sobocinski J, Sediri I, Gautier C, Azzaoui R, Rémy-Jardin M, Haulon S. Benefits of Completion 3D Angiography Associated with Contrast Enhanced Ultrasound to Assess Technical Success after EVAR. Eur J Vasc Endovasc Surg 2015; 49:541-8. [DOI: 10.1016/j.ejvs.2015.01.010] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2014] [Accepted: 01/19/2015] [Indexed: 01/11/2023]
|
26
|
Annoni AD, Andreini D, Pontone G, Formenti A, Petullà M, Consiglio E, Nobili E, Baggiano A, Conte E, Mushtaq S, Bertella E, Billi F, Bartorelli AL, Montorsi P, Pepi M. Ultra-low-dose CT for left atrium and pulmonary veins imaging using new model-based iterative reconstruction algorithm. Eur Heart J Cardiovasc Imaging 2015; 16:1366-73. [PMID: 25911117 DOI: 10.1093/ehjci/jev103] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2014] [Accepted: 04/02/2015] [Indexed: 11/13/2022] Open
Abstract
AIMS To evaluate the feasibility of ultra-low-dose CT for left atrium and pulmonary veins using new model-based iterative reconstruction (MBIR) algorithm. METHODS AND RESULTS Two hundred patients scheduled for catheter ablation were randomized into two groups: Group 1 (100 patients, Multidetector row CT (MDCT) with MBIR, no ECG triggering, tube voltage and tube current of 100 kV and 60 mA, respectively) and Group 2 [100 patients, MDCT with adaptive statistical iterative reconstruction algorithm (ASIR), no ECG triggering, and kV and mA tailored on patient BMI]. Image quality, CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) of left atrium (LA) and pulmonary veins, and effective dose (ED) were evaluated for each exam and compared between two groups.No significant differences between groups in terms of population characteristics, cardiovascular risk factors, anatomical features, prevalence of persistent atrial fibrillation and image quality score. Statistically significant differences were found between Group 1 and Group 2 in mean attenuation, SNR, and CNR of LA. Significantly, lower values of noise were found in Group 1 versus Group 2. Group 1 showed a significantly lower mean ED in comparison with Group 2 (0.41 ± 0.04 versus 4.17 ± 2.7 mSv). CONCLUSION The CT for LA and pulmonary veins imaging using MBIR is feasible and allows examinations with very low-radiation exposure without loss of image quality.
Collapse
Affiliation(s)
- A D Annoni
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - D Andreini
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy Department of Cardiovascular Sciences and Community Health, University of Milan, Milan, Italy
| | - G Pontone
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - A Formenti
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - M Petullà
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - E Consiglio
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - E Nobili
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - A Baggiano
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - E Conte
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - S Mushtaq
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - E Bertella
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - F Billi
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| | - A L Bartorelli
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy Department of Cardiovascular Sciences and Community Health, University of Milan, Milan, Italy
| | - P Montorsi
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy Department of Cardiovascular Sciences and Community Health, University of Milan, Milan, Italy
| | - M Pepi
- Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, Milan 20138, Italy
| |
Collapse
|
27
|
Shen Y, Sun Z, Xu L, Li Y, Zhang N, Yan Z, Fan Z. High-pitch, low-voltage and low-iodine-concentration CT angiography of aorta: assessment of image quality and radiation dose with iterative reconstruction. PLoS One 2015; 10:e0117469. [PMID: 25643353 PMCID: PMC4314070 DOI: 10.1371/journal.pone.0117469] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2014] [Accepted: 12/25/2014] [Indexed: 11/18/2022] Open
Abstract
Objective To assess the image quality of aorta obtained by dual-source computed tomography angiography (DSCTA), performed with high pitch, low tube voltage, and low iodine concentration contrast medium (CM) with images reconstructed using iterative reconstruction (IR). Methods One hundred patients randomly allocated to receive one of two types of CM underwent DSCTA with the electrocardiogram-triggered Flash protocol. In the low-iodine group, 50 patients received CM containing 270 mg I/mL and were scanned at low tube voltage (100 kVp). In the high-iodine CM group, 50 patients received CM containing 370 mg I/mL and were scanned at the tube voltage (120 kVp). The filtered back projection (FBP) algorithm was used for reconstruction in both groups. In addition, the IR algorithm was used in the low-iodine group. Image quality of the aorta was analyzed subjectively by a 3-point grading scale and objectively by measuring the CT attenuation in terms of the signal- and contrast-to-noise ratios (SNR and CNR, respectively). Radiation and CM doses were compared. Results The CT attenuation, subjective image quality assessment, SNR, and CNR of various aortic regions of interest did not differ significantly between two groups. In the low-iodine group, images reconstructed by FBP and IR demonstrated significant differences in image noise, SNR, and CNR (p<0.05). The low-iodine group resulted in 34.3% less radiation (4.4 ± 0.5 mSv) than the high-iodine group (6.7 ± 0.6 mSv), and 27.3% less iodine weight (20.36 ± 2.65 g) than the high-iodine group (28 ± 1.98 g). Observers exhibited excellent agreement on the aortic image quality scores (κ = 0.904). Conclusions CT images of aorta could be obtained within 2 s by using a DSCT Flash protocol with low tube voltage, IR, and low-iodine-concentration CM. Appropriate contrast enhancement was achieved while maintaining good image quality and decreasing the radiation and iodine doses.
Collapse
Affiliation(s)
- Yanguang Shen
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University—Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China
- Department of Radiology, Hospital Affiliated to Hainan Medical College, Haikou, City of Hainan Province, China
| | - Zhonghua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, Perth, Australia
| | - Lei Xu
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University—Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China
| | - Yu Li
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University—Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China
| | - Nan Zhang
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University—Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China
| | - Zixu Yan
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University—Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China
| | - Zhanming Fan
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University—Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China
- * E-mail:
| |
Collapse
|
28
|
Effects of Model-Based Iterative Reconstruction on Image Quality for Low-Dose Computed Tomographic Angiography of the Thoracic Aorta in a Swine Model. J Comput Assist Tomogr 2015; 39:196-201. [DOI: 10.1097/rct.0000000000000180] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
29
|
Hagspiel KD, Flors L, Hanley M, Norton PT. Computed tomography angiography and magnetic resonance angiography imaging of the mesenteric vasculature. Tech Vasc Interv Radiol 2014; 18:2-13. [PMID: 25814198 DOI: 10.1053/j.tvir.2014.12.002] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) are highly accurate cross-sectional vascular imaging modalities that have almost completely replaced diagnostic catheter angiography for the evaluation of the mesenteric vasculature. CTA is the technique of choice when evaluating patients with suspected mesenteric ischemia; it permits to differentiate between occlusive and nonocclusive etiologies, to evaluate indirect signs of bowel ischemia, and in some instances, to provide alternative diagnoses. MRA has the advantage of not using ionizing radiation and iodinated contrast agents and can be appropriate in the nonacute setting. Both CTA and MRA are suitable for the assessment of patients with suspected chronic mesenteric ischemia, allowing to evaluate the degree of atherosclerotic steno-occlusive disease and the existence of collateral circulation, as well as other nonatherosclerotic vascular pathologies such as fibromuscular dysplasia and median arcuate ligament syndrome. CTA provides excellent depiction of visceral aneurysms and has an important role to plan therapy for both occlusive and aneurysmal diseases and in the follow-up of patients after open or endovascular mesenteric revascularization procedures. This article provides an introduction to the CTA and MRA imaging protocol to study the mesenteric vasculature, the imaging findings in patients presenting with acute and chronic mesenteric ischemia and visceral aneurysms, and the value of these imaging techniques for therapy planning and follow-up.
Collapse
Affiliation(s)
- Klaus D Hagspiel
- Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, VA.
| | - Lucia Flors
- Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, VA
| | - Michael Hanley
- Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, VA
| | - Patrick T Norton
- Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, VA
| |
Collapse
|
30
|
Assessment of 1 mSv Urinary Tract Stone CT With Model-Based Iterative Reconstruction. AJR Am J Roentgenol 2014; 203:1230-5. [DOI: 10.2214/ajr.13.12271] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|