1
|
Jensen CT, Wong VK, Likhari GS, Daoud TE, Bassett R, Pasyar S, Imai Y, Shigemasa R, Roman-Colon AM, Li K, Liu X. Novel Deep Learning Reconstruction to Augment Contrast Enhancement: Initial Evaluation. J Comput Assist Tomogr 2025:00004728-990000000-00446. [PMID: 40249273 DOI: 10.1097/rct.0000000000001755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2024] [Accepted: 03/06/2025] [Indexed: 04/19/2025]
Abstract
OBJECTIVE To assess image quality between single-energy CT (SECT) and dual-energy CT (DECT) scans compared with a novel deep learning (DL) reconstruction for SECT used to improve contrast enhancement. METHODS The raw data from a prior prospective HIPAA-compliant study (March through August 2022) was used to create a novel reconstruction in patients with biopsy-proven colorectal adenocarcinoma and liver metastases. Patients underwent 120 kVp SECT and DECT (50 keV reconstruction) abdominal scans in the portal venous phase in the same breath hold. Two readers independently assessed the scans. RESULTS The final study group was 13 men and 2 women with a mean age of 60 years ± 10, a mean height of 171 cm ± 8, a mean weight of 87 kg ± 23, and a mean body mass index of 30 kg/m2 ± 6. Liver, pancreas, spleen, psoas muscle, and aorta HUs were all significantly higher with the virtual DL reconstruction compared with the 120 kVp series, but significantly lower than the 50 keV series (P<0.05). Readers scored the DL reconstruction to have better contrast enhancement than the standard 120 kVp series and improved artifacts, noise texture, and resolution compared with the 50 keV series (P<0.05). CONCLUSIONS Contrast enhancement with the new reconstruction is superior compared with the standard 120 kVp series approaching that of 50 keV DECT, but with improved perception of artifacts, noise texture, and resolution.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Yasuhiro Imai
- CT Systems Engineering, MICT Engineering, GE HealthCare, Tokyo, Japan
| | - Risa Shigemasa
- CT Systems Engineering, MICT Engineering, GE HealthCare, Tokyo, Japan
| | | | - Ke Li
- Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Xinming Liu
- Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
2
|
Racine D, Mergen V, Viry A, Frauenfelder T, Alkadhi H, Vitzthum V, Euler A. Photon-Counting Detector CT for Liver Lesion Detection-Optimal Virtual Monoenergetic Energy for Different Simulated Patient Sizes and Radiation Doses. Invest Radiol 2024; 59:554-560. [PMID: 38193782 DOI: 10.1097/rli.0000000000001060] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
OBJECTIVES The aim of this study was to evaluate the optimal energy level of virtual monoenergetic images (VMIs) from photon-counting detector computed tomography (CT) for the detection of liver lesions as a function of phantom size and radiation dose. MATERIALS AND METHODS An anthropomorphic abdominal phantom with liver parenchyma and lesions was imaged on a dual-source photon-counting detector CT at 120 kVp. Five hypoattenuating lesions with a lesion-to-background contrast difference of -30 HU and -45 HU and 3 hyperattenuating lesions with +30 HU and +90 HU were used. The lesion diameter was 5-10 mm. Rings of fat-equivalent material were added to emulate medium- or large-sized patients. The medium size was imaged at a volume CT dose index of 5, 2.5, and 1.25 mGy and the large size at 5 and 2.5 mGy, respectively. Each setup was imaged 10 times. For each setup, VMIs from 40 to 80 keV at 5 keV increments were reconstructed with quantum iterative reconstruction at a strength level of 4 (QIR-4). Lesion detectability was measured as area under the receiver operating curve (AUC) using a channelized Hotelling model observer with 10 dense differences of Gaussian channels. RESULTS Overall, highest detectability was found at 65 and 70 keV for both hypoattenuating and hyperattenuating lesions in the medium and large phantom independent of radiation dose (AUC range, 0.91-1.0 for the medium and 0.94-0.99 for the large phantom, respectively). The lowest detectability was found at 40 keV irrespective of the radiation dose and phantom size (AUC range, 0.78-0.99). A more pronounced reduction in detectability was apparent at 40-50 keV as compared with 65-75 keV when radiation dose was decreased. At equal radiation dose, detection as a function of VMI energy differed stronger for the large size as compared with the medium-sized phantom (12% vs 6%). CONCLUSIONS Detectability of hypoattenuating and hyperattenuating liver lesions differed between VMI energies for different phantom sizes and radiation doses. Virtual monoenergetic images at 65 and 70 keV yielded highest detectability independent of phantom size and radiation dose.
Collapse
Affiliation(s)
- Damien Racine
- From the Institute of Radiation Physics, University Hospital Lausanne (CHUV), University of Lausanne, Lausanne, Switzerland (D.R., A.V., V.V.); Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (V.M., T.F., H.A., A.E.); and Department of Radiology, Kantonsspital Baden, Baden, Switzerland (A.E.)
| | | | | | | | | | | | | |
Collapse
|
3
|
Nehra AK, Dane B, Yeh BM, Fletcher JG, Leng S, Mileto A. Dual-Energy, Spectral and Photon Counting Computed Tomography for Evaluation of the Gastrointestinal Tract. Radiol Clin North Am 2023; 61:1031-1049. [PMID: 37758355 DOI: 10.1016/j.rcl.2023.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
The use of dual-energy computed tomography (CT) allows for reconstruction of energy- and material-specific image series. The combination of low-energy monochromatic images, iodine maps, and virtual unenhanced images can improve lesion detection and disease characterization in the gastrointestinal tract in comparison with single-energy CT.
Collapse
Affiliation(s)
- Avinash K Nehra
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA.
| | - Bari Dane
- Department of Radiology, New York University Langone Medical Center, 550 First Avenue, New York, NY 10016, USA
| | - Benjamin M Yeh
- Department of Radiology and Biomedical Imaging, University of California, 505 Parnassus Avenue, San Francisco, CA 94143, USA
| | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| | - Achille Mileto
- Department of Radiology, Virginia Mason Medical Center, 1100 9th Avenue, Seattle, WA 98101, USA
| |
Collapse
|
4
|
Li S, Yuan L, Lu T, Yang X, Ren W, Wang L, Zhao J, Deng J, Liu X, Xue C, Sun Q, Zhang W, Zhou J. Deep learning imaging reconstruction of reduced-dose 40 keV virtual monoenergetic imaging for early detection of colorectal cancer liver metastases. Eur J Radiol 2023; 168:111128. [PMID: 37816301 DOI: 10.1016/j.ejrad.2023.111128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 08/07/2023] [Accepted: 09/28/2023] [Indexed: 10/12/2023]
Abstract
OBJECTIVE To explore whether reduced-dose (RD) gemstone spectral imaging (GSI) and deep learning image reconstruction (DLIR) of 40 keV virtual monoenergetic image (VMI) enhanced the early detection and diagnosis of colorectal cancer liver metastases (CRLM). METHODS Thirty-five participants with pathologically confirmed colorectal cancer were prospectively enrolled from March to August 2022 after routine care abdominal computed tomography (CT). GSI mode was used for contrast-enhanced CT, and two portal venous phase CT images were obtained [standard-dose (SD) CT dose index (CTDIvol) = 15.51 mGy, RD CTDIvol = 7.95 mGy]. The 40 keV-VMI were reconstructed via filtered back projection (FBP) and iterative reconstruction (ASIR-V 60 %, AV60) of both SD and RD images. RD medium-strength deep learning image reconstruction (DLIR-M) and RD high-strength deep learning image reconstruction (DLIR-H) were used to reconstruct the 40 keV-VMI. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the liver and the lesions were objectively evaluated. The overall image quality, lesion conspicuity, and diagnostic confidence were subjectively evaluated, to compare the differences in evaluation results among the different images. RESULTS All 35 participants (mean age: 59.51 ± 11.01 years; 14 females) underwent SD and RD GSI portal venous-phase CT scans. The dose-length product of the RD GSI scan was reduced by 49-53 % lower than that of the SD GSI scan (420.22 ± 31.95) vs (817.58 ± 60.56). A total of 219 lesions were identified, including 55 benign lesions and 164 metastases, with an average size of 7.37 ± 4.14 mm. SD-FBP detected 207 lesions, SD-AV60 detected 201 lesions, and DLIR-M and DLIR-H detected 199 and 190 lesions, respectively. For lesions ≤ 5 mm, there was no statistical difference between SD-FBP vs DLIR-M (χ2McNemar = 1.00, P = 0.32) and SD-AV60 vs DLIR-M (χ2McNemar = 0.33, P = 0.56) in the detection rate. The CNR, SNR, and noise of DLIR-M and DLIR-H 40 keV-VMI images were better than those of SD-FBP images (P < 0.01) but did not differ significantly from those of SD-AV60 images (P > 0.05). When the lesions ≤ 5 mm, there were statistical differences in the overall diagnostic sensitivity of lesions compared with SD-FBP, SD-AV60, DLIR-M and DLIR-H (P<0.01). There were no statistical differences in the sensitivity of lesions diagnosis between SD-FBP, SD-AV60 and DLIR-M (both P>0.05). However, the DLIR-M subjective image quality and lesion diagnostic confidence were higher for SD-FBP (both P < 0.01). CONCLUSION Reduced dose DLIR-M of 40 keV-VMI can be used for routine follow-up care of colorectal cancer patients, to optimize evaluations and ensure CT image quality. Meanwhile, the detection rate and diagnostic sensitivity and specificity of small lesions, early liver metastases is not obviously reduced.
Collapse
Affiliation(s)
- Shenglin Li
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China.
| | - Long Yuan
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China.
| | - Ting Lu
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China.
| | - Xinmei Yang
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China.
| | - Wei Ren
- CT Imaging Research Center, GE Healthcare China, Beijing, 100176, China.
| | - Luotong Wang
- CT Imaging Research Center, GE Healthcare China, Beijing, 100176, China.
| | - Jun Zhao
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China.
| | - Juan Deng
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China.
| | - Xianwang Liu
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China.
| | - Caiqiang Xue
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China.
| | - Qiu Sun
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China.
| | - Wenjuan Zhang
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China.
| | - Junlin Zhou
- Department of Radiology, Lanzhou University Second Hospital, Cuiyingmen No.82, Chengguan District, Lanzhou, 730030, China; Second clinical school, Lanzhou University, Lanzhou, China; Key Laboratory of Medical Imaging of Gansu Province, Lanzhou, China; Gansu International Scientific and Technological Cooperation Base of Medical Imaging Artificial Intelligence, Lanzhou, China.
| |
Collapse
|
5
|
Borges AP, Antunes C, Caseiro-Alves F. Spectral CT: Current Liver Applications. Diagnostics (Basel) 2023; 13:diagnostics13101673. [PMID: 37238163 DOI: 10.3390/diagnostics13101673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 05/02/2023] [Accepted: 05/04/2023] [Indexed: 05/28/2023] Open
Abstract
Using two different energy levels, dual-energy computed tomography (DECT) allows for material differentiation, improves image quality and iodine conspicuity, and allows researchers the opportunity to determine iodine contrast and radiation dose reduction. Several commercialized platforms with different acquisition techniques are constantly being improved. Furthermore, DECT clinical applications and advantages are continually being reported in a wide range of diseases. We aimed to review the current applications of and challenges in using DECT in the treatment of liver diseases. The greater contrast provided by low-energy reconstructed images and the capability of iodine quantification have been mostly valuable for lesion detection and characterization, accurate staging, treatment response assessment, and thrombi characterization. Material decomposition techniques allow for the non-invasive quantification of fat/iron deposition and fibrosis. Reduced image quality with larger body sizes, cross-vendor and scanner variability, and long reconstruction time are among the limitations of DECT. Promising techniques for improving image quality with lower radiation dose include the deep learning imaging reconstruction method and novel spectral photon-counting computed tomography.
Collapse
Affiliation(s)
- Ana P Borges
- Medical Imaging Department, Coimbra University Hospitals, 3004-561 Coimbra, Portugal
- Faculty of Medicine, University of Coimbra, 3004-504 Coimbra, Portugal
- Academic and Clinical Centre of Coimbra, 3000-370 Coimbra, Portugal
| | - Célia Antunes
- Medical Imaging Department, Coimbra University Hospitals, 3004-561 Coimbra, Portugal
- Academic and Clinical Centre of Coimbra, 3000-370 Coimbra, Portugal
| | - Filipe Caseiro-Alves
- Medical Imaging Department, Coimbra University Hospitals, 3004-561 Coimbra, Portugal
- Faculty of Medicine, University of Coimbra, 3004-504 Coimbra, Portugal
- Academic and Clinical Centre of Coimbra, 3000-370 Coimbra, Portugal
| |
Collapse
|
6
|
Narita K, Nakamura Y, Higaki T, Kondo S, Honda Y, Kawashita I, Mitani H, Fukumoto W, Tani C, Chosa K, Tatsugami F, Awai K. Iodine maps derived from sparse-view kV-switching dual-energy CT equipped with a deep learning reconstruction for diagnosis of hepatocellular carcinoma. Sci Rep 2023; 13:3603. [PMID: 36869102 PMCID: PMC9984536 DOI: 10.1038/s41598-023-30460-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Accepted: 02/23/2023] [Indexed: 03/05/2023] Open
Abstract
Deep learning-based spectral CT imaging (DL-SCTI) is a novel type of fast kilovolt-switching dual-energy CT equipped with a cascaded deep-learning reconstruction which completes the views missing in the sinogram space and improves the image quality in the image space because it uses deep convolutional neural networks trained on fully sampled dual-energy data acquired via dual kV rotations. We investigated the clinical utility of iodine maps generated from DL-SCTI scans for assessing hepatocellular carcinoma (HCC). In the clinical study, dynamic DL-SCTI scans (tube voltage 135 and 80 kV) were acquired in 52 patients with hypervascular HCCs whose vascularity was confirmed by CT during hepatic arteriography. Virtual monochromatic 70 keV images served as the reference images. Iodine maps were reconstructed using three-material decomposition (fat, healthy liver tissue, iodine). A radiologist calculated the contrast-to-noise ratio (CNR) during the hepatic arterial phase (CNRa) and the equilibrium phase (CNRe). In the phantom study, DL-SCTI scans (tube voltage 135 and 80 kV) were acquired to assess the accuracy of iodine maps; the iodine concentration was known. The CNRa was significantly higher on the iodine maps than on 70 keV images (p < 0.01). The CNRe was significantly higher on 70 keV images than on iodine maps (p < 0.01). The estimated iodine concentration derived from DL-SCTI scans in the phantom study was highly correlated with the known iodine concentration. It was underestimated in small-diameter modules and in large-diameter modules with an iodine concentration of less than 2.0 mgI/ml. Iodine maps generated from DL-SCTI scans can improve the CNR for HCCs during hepatic arterial phase but not during equilibrium phase in comparison with virtual monochromatic 70 keV images. Also, when the lesion is small or the iodine concentration is low, iodine quantification may result in underestimation.
Collapse
Affiliation(s)
- Keigo Narita
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Yuko Nakamura
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan.
| | - Toru Higaki
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
- Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima, Hiroshima, 739-8527, Japan
| | - Shota Kondo
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Yukiko Honda
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Ikuo Kawashita
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Hidenori Mitani
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Wataru Fukumoto
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Chihiro Tani
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Keigo Chosa
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Fuminari Tatsugami
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Kazuo Awai
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| |
Collapse
|
7
|
An introduction to photon-counting detector CT (PCD CT) for radiologists. Jpn J Radiol 2023; 41:266-282. [PMID: 36255601 PMCID: PMC9974724 DOI: 10.1007/s11604-022-01350-6] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 10/01/2022] [Indexed: 10/24/2022]
Abstract
The basic performance of photon-counting detector computed tomography (PCD CT) is superior to conventional CT (energy-integrating detector CT: EID CT) because its spatial- and contrast resolution of soft tissues is higher, and artifacts are reduced. Because the X-ray photon energy separation is better with PCD CT than conventional EID-based dual-energy CT, it has the potential to improve virtual monochromatic- and virtual non-contrast images, material decomposition including quantification of the iodine distribution, and K-edge imaging. Therefore, its clinical applicability may be increased. Although the image quality of PCD CT scans is superior to that of EID CT currently, further improvement may be possible. The introduction of iterative image reconstruction and reconstruction with deep convolutional neural networks will be useful.
Collapse
|
8
|
Liang H, Zhou Y, Zheng Q, Yan G, Liao H, Du S, Zhang X, Lv F, Zhang Z, Li YM. Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma. Insights Imaging 2022; 13:153. [PMID: 36153376 PMCID: PMC9509509 DOI: 10.1186/s13244-022-01297-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 09/05/2022] [Indexed: 11/10/2022] Open
Abstract
Objectives To evaluate the value of monoenergetic images (MEI [+]) and iodine maps in dual-source dual-energy computed tomography (DECT) for assessing pancreatic ductal adenocarcinoma (PDAC), including the visually isoattenuating PDAC. Materials and methods This retrospective study included 75 PDAC patients, who underwent contrast-enhanced DECT examinations. Conventional polyenergetic image (PEI) and 40–80 keV MEI (+) (10-keV increments) were reconstructed. The tumor contrast, contrast-to-noise ratio (CNR) of the tumor and peripancreatic vessels, the signal-to-noise ratio (SNR) of the pancreas and tumor, and the tumor diameters were quantified. On iodine maps, the normalized iodine concentration (NIC) in the tumor and parenchyma was compared. For subjective analysis, two radiologists independently evaluated images on a 5-point scale. Results All the quantitative parameters were maximized at 40-keV MEI (+) and decreased gradually with increasing energy. The tumor contrast, SNR of pancreas and CNRs in 40–60 keV MEI (+) were significantly higher than those in PEI (p < 0.05). For visually isoattenuating PDAC, 40–50 keV MEI (+) provided significantly higher tumor CNR compared to PEI (p < 0.05). The reproducibility in tumor measurements was highest in 40-keV MEI (+) between the two radiologists. The tumor and parenchyma NIC were 1.28 ± 0.65 and 3.38 ± 0.72 mg/mL, respectively (p < 0.001). 40–50 keV MEI (+) provided the highest subjective scores, compared to PEI (p < 0.001). Conclusions Low-keV MEI (+) of DECT substantially improves the subjective and objective image quality and consistency of tumor measurements in patients with PDAC. Combining the low-keV MEI (+) and iodine maps may yield diagnostically adequate tumor conspicuity in visually isoattenuating PDAC.
Collapse
|
9
|
Hepatobiliary Dual-Energy Computed Tomography. Radiol Clin North Am 2022; 60:731-743. [DOI: 10.1016/j.rcl.2022.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
10
|
Lennartz S, Hokamp NG, Kambadakone A. Dual-Energy CT of the Abdomen: Radiology In Training. Radiology 2022; 305:19-27. [PMID: 35727149 DOI: 10.1148/radiol.212914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A 61-year-old man with an esophageal cancer diagnosis underwent staging dual-energy CT of the chest and abdomen in the portal venous phase after contrast media administration. Aside from the primary tumor and suspicious local lymph nodes, CT revealed hypoattenuating ambiguous liver lesions, an incidental right adrenal nodule, and a right renal lesion with soft-tissue attenuation. In addition, advanced atherosclerosis of the abdominal aorta and its major branches was noted. This article provides a case-based review of dual-energy CT technologies and their applications in the abdomen. The clinical utility of virtual monoenergetic images, virtual unenhanced images, and iodine maps is discussed.
Collapse
Affiliation(s)
- Simon Lennartz
- From the Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Strasse 62, 50937 Cologne, Germany (S.L., N.G.H.); and Department of Radiology, Division of Abdominal Imaging, Massachusetts General Hospital, Boston, Mass (A.K.)
| | - Nils Große Hokamp
- From the Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Strasse 62, 50937 Cologne, Germany (S.L., N.G.H.); and Department of Radiology, Division of Abdominal Imaging, Massachusetts General Hospital, Boston, Mass (A.K.)
| | - Avinash Kambadakone
- From the Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Strasse 62, 50937 Cologne, Germany (S.L., N.G.H.); and Department of Radiology, Division of Abdominal Imaging, Massachusetts General Hospital, Boston, Mass (A.K.)
| |
Collapse
|
11
|
Bongers MN, Walter S, Fritz J, Bier G, Horger M, Artzner C. Interindividual Comparison of Frequency-Selective Nonlinear Blending to Conventional CT for Detection of Focal Liver Lesions Using MRI as the Reference Standard. AJR Am J Roentgenol 2022; 218:1021-1029. [PMID: 35018796 DOI: 10.2214/ajr.21.26922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND. Diagnosing liver lesions is challenging. CT is used for primary diagnosis, but its contrast resolution is limited. Investigating methods to improve detection of liver lesions is important. OBJECTIVE. The purpose of this study was to evaluate the effect of frequency-selective nonlinear blending on the detectability of liver lesions on CT. METHODS. A retrospective search yielded 109 patients with 356 malignant and benign liver lesions (191 principally diagnosed, 165 incidental findings) who underwent contrast-enhanced CT (CECT) in the portal venous phase and liver MRI between January 2012 and December 2017. Nonlinear blending was applied to CECT examinations, and three blinded readers independently rated the quality (5-point Likert scale) of randomly presented images. Focal lesions (n = 356) were evaluated for lesion identification and categorization to assess sensitivity. For 191 lesions (primary diagnosis), two readers evaluated CECT and nonlinear blending CT to compare lesion size and the accuracy of subjective measurements. A fourth reader performed ROI measurements for calculation of contrast-to-noise ratio (CNR), and a fifth reader reviewed MRI as the standard of reference. Statistics included interobserver agreement, quantitative comparisons of CNR, lesion size, and subjective image analyses of image quality and sensitivity for detecting liver lesions. RESULTS. Three readers rated the image quality of nonlinear blending CT (rating, 4; 10th-90th percentiles, 4-5) higher than that of CECT (rating, 2; 10th-90th percentiles, 1-3) (p < .001). CECT had good interreader agreement (interclass correlation coefficient [ICC], 0.81; 95% CI, 0.76-0.85), as did nonlinear blending CT (ICC, 0.75; 95% CI, 0.69-0.79). The median CNR of liver lesions increased with nonlinear blending (CECT, 4.18 [10th-90th percentiles, 1.67-9.06]; nonlinear blending CT, 12.49 [10th-90th percentiles, 6.18-23.39]; p < .001). Bland-Altman analysis of lesion size showed a reduction in underestimation from 2.5 (SD, 9.2) mm (95% CI, 1.2-3.9 mm) with CECT to 0.1 (SD, 3.9) mm (95% CI, -0.68 to 0.46 mm) for nonlinear blending CT (concordance correlation coefficient, 0.99). Sensitivity for detecting liver lesions increased to 86% for nonlinear blending CT. The sensitivity of CECT was 76%. CONCLUSION. Frequency-selective nonlinear blending in CECT increases image quality and CNR, increases the precision of size measurement, and increases sensitivity for detecting liver lesions. CLINICAL IMPACT. Use of nonlinear blending CT improves liver lesion detection and increases the accuracy of lesion size measurement, which is important when local ablation or liver transplant is being considered.
Collapse
Affiliation(s)
- Malte N Bongers
- Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Hoppe-Seyler-Str 3, Tübingen 72076, Germany
| | - Sven Walter
- Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Hoppe-Seyler-Str 3, Tübingen 72076, Germany
- Department of Radiology, NYU Grossman School of Medicine, New York, NY
| | - Jan Fritz
- Department of Radiology, NYU Grossman School of Medicine, New York, NY
| | - Georg Bier
- Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Hoppe-Seyler-Str 3, Tübingen 72076, Germany
| | - Marius Horger
- Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Hoppe-Seyler-Str 3, Tübingen 72076, Germany
| | - Christoph Artzner
- Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Hoppe-Seyler-Str 3, Tübingen 72076, Germany
| |
Collapse
|
12
|
Narappulan N, Arunachalam VK, Alavandar E, Selvaraja S, Renganathan R, Cherian M. Evaluation of Hypervascular Focal Liver Lesions Utilizing Virtual Monoenergetic Images from Third-Generation Dual-Source Dual-Energy Computed Tomography. JOURNAL OF GASTROINTESTINAL AND ABDOMINAL RADIOLOGY 2022. [DOI: 10.1055/s-0042-1742677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Abstract
Objectives The purpose of our study was to evaluate the virtual monochromatic imaging in detecting hypervascular focal liver lesions in the late arterial phase with third-generation dual-source dual-energy computed tomography and to assess its image quality.
Materials and Methods In our study, 80 patients were included. Contrast-enhanced images in the late arterial phase (in the dual-energy mode) were acquired and were post-processed in Syngo, via workstation, using Monoenergetic + software. Five sets of images, one polychromatic energy image (corresponding to 120 kVp single-energy image) and four virtual monoenergetic image (VMI) sets at 40, 50, 60, and 70 keV levels, were generated. All these images were analyzed both objectively and subjectively. The attenuation values were measured, and the contrast-to-noise ratio (CNR) of liver and tumor were measured and compared objectively in each dataset. Image noise, image contrast, and diagnostic confidence for liver lesion detection were analyzed subjectively using a five-point scale system. Statistical analysis was performed using Kolmogorov–Smirnov, analysis of variance, and Kruskal–Wallis tests.
Results Among the VMI, maximum image noise was observed in the 40 keV image, with a gradual reduction in the image noise being noted with an increase in the VMI energy. The CNR of the hepatic parenchyma and the tumor gradually increased with a reduction in VMI energy from 70 to 40 keV. On subjective analysis, image contrast and image noise were observed to be more in low VMI datasets. In lesion detection, diagnostic confidence with an excellent confidence level was observed with a decrease in VMI energy.
Conclusion VMI datasets of 40 to 70 keV from third-generation dual-source DECT provide superior diagnostic accuracy for detecting hypervascular liver lesions. Considering the image noise and lesion detection rate among the VMI datasets, 60 keV VMI is the most helpful dataset for increased liver lesion detection with good image quality.
Collapse
Affiliation(s)
- Niyas Narappulan
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India
| | | | | | - Swathigha Selvaraja
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India
| | - Rupa Renganathan
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India
| | - Mathew Cherian
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India
| |
Collapse
|
13
|
Euler A, Zadory M, Breiding PS, Sartoretti T, Ghafoor S, Froehlich JM, Donati OF. Realistic Kidney Tissue Surrogates for Multienergy Computed Tomography-Feasibility and Estimation of Energy-Dependent Attenuation Thresholds for Renal Lesion Enhancement in Low-kV and Virtual Monoenergetic Imaging. Invest Radiol 2021; 56:791-798. [PMID: 33899757 DOI: 10.1097/rli.0000000000000790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE The aims of this study were to assess if kidney tissue surrogates (KTSs) are superior to distilled water-iodine solutions in the emulation of energy-dependent computed tomography (CT) attenuation characteristics of renal parenchyma and to estimate attenuation thresholds for definite lesion enhancement for low-kV single-energy and low-keV dual-energy virtual monoenergetic imaging. METHODS A water-filled phantom (diameter, 30 cm) with multiple vials was imaged on a dual-source dual-energy CT (DS-DE) and a single-source split-filter dual-energy CT (SF-DE), both in single-energy mode at 80, 100, 120, 140 kVp and in dual-energy mode at 80/Sn150, 90/Sn150, and 100/Sn150 kVp for DS-DE and AuSn120 kVp for SF-DE. Single-energy images, linear-blended dual-energy images, and virtual monoenergetic imaging at energy levels from 40 to 190 keV were reconstructed. First, attenuation characteristics of KTS in solid and liquid consistencies were compared. Second, solid KTSs were developed to match the CT attenuation of unenhanced renal parenchyma at 120 kVp as retrospectively measured in 100 patients. Third, CT attenuation of KTS-iodine and water-iodine solutions at 8 different iodine concentrations (0-10 mg I/mL) were compared as a function of tube voltage and of keV level using multiple linear regression models. Energy-dependent attenuation thresholds for definite lesion enhancement were calculated. RESULTS Unenhanced renal parenchyma at 120 kVp measured on average 30 HU on both scanners in the patient cohort. Solid KTS with a water content of 80% emulated the attenuation of unenhanced renal parenchyma (30 HU) more accurately compared with water-iodine solutions (0 HU). Attenuation difference between KTS-iodine and water-iodine solutions converged with increasing iodine concentration and decreasing x-ray energy due to beam-hardening effects. A slight attenuation difference of approximately 2 HU was found between the 2 CT scanners. Attenuation thresholds for definite lesion enhancement were dependent on tube voltage and keV level and ranged from 16.6 to 33.2 HU and 3.2 to 68.3 HU for single-energy and dual-energy CT scan modes for DS-DE and from 16.1 to 34.3 HU and 3.3 to 92.2 HU for SF-DE. CONCLUSIONS Kidney tissue surrogates more accurately emulate the energy-dependent CT attenuation characteristics of renal parenchyma for multienergy CT compared with conventional water-iodine approaches. Energy-dependent thresholds for definite lesion enhancement could facilitate lesion characterization when imaging at different energies than the traditional 120 kVp.
Collapse
Affiliation(s)
- André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich
| | | | - Philipe Sebastian Breiding
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich
| | | | - Soleen Ghafoor
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich
| | | | - Olivio Fabrizio Donati
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich
| |
Collapse
|
14
|
Voss BA, Khandelwal A, Wells ML, Inoue A, Venkatesh SK, Lee YS, Johnson MP, Fletcher JG. Impact of dual-energy 50-keV virtual monoenergetic images on radiologist confidence in detection of key imaging findings of small hepatocellular carcinomas using multiphase liver CT. Acta Radiol 2021; 63:1443-1452. [PMID: 34723681 DOI: 10.1177/02841851211052993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Dual-energy virtual monoenergetic images can increase iodine signal, potentially increasing the conspicuity of hepatic masses. PURPOSE To determine if dual-energy 50-keV virtual monoenergetic images improve visualization of key imaging findings or diagnostic confidence for small (≤2 cm) hepatocellular carcinomas (HCC) at multiphase, contrast-enhanced liver computed tomography (CT). MATERIAL AND METHODS Patients with chronic liver disease underwent multiphase dual-energy CT imaging for HCC, with late arterial and delayed phase dual-energy 50-keV images reconstructed. Two non-reader subspecialized gastrointestinal (GI) radiologists established the reference standard, determining the location and diagnosis of all hepatic lesions using predetermined criteria. Three GI radiologists interpreted mixed kV CT images without or with dual-energy 50-keV images. Radiologists identified potential HCCs and rated their confidence (0-100 scales) in imaging findings of arterial enhancement, enhancing capsule, tumor washout, and LI-RADS 5 (2018) category. RESULTS In total, 45 patients (14 women; mean age = 59.5 ± 10.9 years) with chronic liver disease were included. Of them, 19 patients had 25 HCCs ≤2 cm (mean size = 1.5 ± 0.4 cm). There were 17 LI-RADS 3 and 4 lesions and 19 benign lesions. Reader confidence in imaging findings of arterial enhancement, enhancing capsule, and non-peripheral washout significantly increased with dual-energy images (P ≤ 0.022). Overall confidence in HCC diagnosis increased significantly with dual-energy 50-keV images (52.4 vs. 68.8; P = 0.001). Dual-energy images demonstrated a slight but significant decrease in overall image quality. CONCLUSION Radiologist confidence in key imaging features of small HCCs and confidence in imaging diagnosis increases with use of dual-energy 50-keV images at multiphase, contrast-enhanced liver CT.
Collapse
Affiliation(s)
| | | | | | - Akitoshi Inoue
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Yong S Lee
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Matthew P Johnson
- Biomedical Statistics and Informatics, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
15
|
Spectral CT Hybrid Images in the Diagnostic Evaluation of Hypervascular Abdominal Tumors-Potential Advantages in Clinical Routine. Diagnostics (Basel) 2021; 11:diagnostics11091539. [PMID: 34573880 PMCID: PMC8471266 DOI: 10.3390/diagnostics11091539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/18/2021] [Accepted: 08/23/2021] [Indexed: 12/04/2022] Open
Abstract
Background: This study aimed to investigate the use of spectral computed tomography (SCT) hybrid images combining virtual monoenergetic images (VMIs) and iodine maps (IMs) as a potentially efficient search series for routine clinical imaging in patients with hypervascular abdominal tumors. Methods: A total of 69 patients with hypervascular abdominal tumors including neuroendocrine neoplasms (NENs, n = 48), renal cell carcinoma (RCC, n = 10), and primary hepatocellular carcinoma (HCC, n = 11) were analyzed retrospectively. Two radiological readers (blinded to clinical data) read three CT image sets (1st a reference set with 70 keV; 2nd a 50:50 hybrid 140 keV/40 keV set; 3rd a 50:50 hybrid 140 keV/IM set). They assessed images subjectively by rating several parameters including image contrast, visibility of suspicious lesions, and diagnostic confidence on five-point Likert scales. In addition, reading time was estimated. Results: Median subjective Likert scores were highest for the 1st set, except for image contrast, for which the 2nd set was rated highest. Scores for diagnostic confidence, artifacts, noise, and visibility of suspicious lesions or small structures were significantly higher for the 1st set than for the 2nd or 3rd set (p < 0.001). Regarding image contrast, the 2nd set was rated significantly higher than the 3rd set (p < 0.001), while the median did not differ significantly compared with the 1st set. Agreement between the two readers was high for all sets. Estimated potential reading time was the same for hybrid and reference sets. Conclusions: Hybrid images have the potential to efficiently exploit the additional information provided by SCT in patients with hypervascular abdominal tumors. However, the use of rigid weighting did not significantly improve diagnostic performance in this study.
Collapse
|
16
|
Lennartz S, Parakh A, Cao J, Zopfs D, Große Hokamp N, Kambadakone A. Inter-scan and inter-scanner variation of quantitative dual-energy CT: evaluation with three different scanner types. Eur Radiol 2021; 31:4438-4451. [PMID: 33443600 DOI: 10.1007/s00330-020-07611-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 11/23/2020] [Accepted: 12/04/2020] [Indexed: 03/24/2023]
Abstract
OBJECTIVES To investigate inter-scan and inter-scanner variation of iodine concentration (IC) and attenuation in virtual monoenergetic images at 65 keV (HU65keV) in patients with repeated abdominal examinations on dual-source (dsDECT), rapid kV switching (rsDECT), and dual-layer detector DECT (dlDECT). METHODS We retrospectively included 131 patients who underwent two abdominal DECT examinations on the same scanner (dsDECT: n = 46, rsDECT: n = 45, dlDECT: n = 40). IC and HU65keV were measured by placing regions of interest in the liver, spleen, kidneys, aorta, portal vein, and inferior vena cava. Overall IC and HU65keV for each scanner, their inter-scan differences and proportional variation were calculated and compared between scanner types. RESULTS The three scanner-specific cohorts showed similar weight, body diameter, age, sex, and contrast media injection parameters as well as inter-scan differences hereof (p range: 0.23-0.99). Absolute inter-scan differences of HU65keV and IC were comparable between scanners (p range: 0.08-1.0). Overall inter-scan variation was significantly higher in IC than HU65keV (p < 0.05). For the liver, rsDECT showed significantly lower inter-scan variation of IC compared to dsDECT/dlDECT (p = 0.005/0.01), while for the spleen, this difference was only significant compared to dsDECT (p = 0.015). Normalizing IC of the liver to the portal vein and of the spleen to the aorta did not significantly reduce inter-scan variation (p = 0.97 and 0.50). CONCLUSIONS Iodine measurements across different DECT scanners show inter-scan variation which is higher compared to variation of attenuation values. Inter-scanner differences in longitudinal variation and overall iodine concentration depend on the scanner pairs and organs assessed and should be acknowledged in clinical and scientific DECT applications. KEY POINTS • All scanner types showed comparable inter-scan variation of attenuation, while for iodine, the rapid kV switching DECT showed lower variability in the liver and spleen. • Iodine concentration showed higher inter-scan variation than attenuation measurements; normalization to vessels did not significantly improve inter-scan reproducibility of iodine concentration in parenchymal organs. • Differences between the three scanner types regarding overall iodine concentration and attenuation obtained from both timepoints were within the range of average intra-patient, inter-scan differences for most assessed organs and vessels.
Collapse
Affiliation(s)
- Simon Lennartz
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA
- Institute for Diagnostic and Interventional Radiology, University Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Anushri Parakh
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA
| | - Jinjin Cao
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA
| | - David Zopfs
- Institute for Diagnostic and Interventional Radiology, University Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Nils Große Hokamp
- Institute for Diagnostic and Interventional Radiology, University Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114, USA.
| |
Collapse
|
17
|
Nakamura Y, Higaki T, Honda Y, Tatsugami F, Tani C, Fukumoto W, Narita K, Kondo S, Akagi M, Awai K. Advanced CT techniques for assessing hepatocellular carcinoma. Radiol Med 2021; 126:925-935. [PMID: 33954894 DOI: 10.1007/s11547-021-01366-4] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 04/26/2021] [Indexed: 02/07/2023]
Abstract
Hepatocellular carcinoma (HCC) is the sixth-most common cancer in the world, and hepatic dynamic CT studies are routinely performed for its evaluation. Ongoing studies are examining advanced imaging techniques that may yield better findings than are obtained with conventional hepatic dynamic CT scanning. Dual-energy CT-, perfusion CT-, and artificial intelligence-based methods can be used for the precise characterization of liver tumors, the quantification of treatment responses, and for predicting the overall survival rate of patients. In this review, the advantages and disadvantages of conventional hepatic dynamic CT imaging are reviewed and the general principles of dual-energy- and perfusion CT, and the clinical applications and limitations of these technologies are discussed with respect to HCC. Finally, we address the utility of artificial intelligence-based methods for diagnosing HCC.
Collapse
Affiliation(s)
- Yuko Nakamura
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan.
| | - Toru Higaki
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Yukiko Honda
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Fuminari Tatsugami
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Chihiro Tani
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Wataru Fukumoto
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Keigo Narita
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Shota Kondo
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Motonori Akagi
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Kazuo Awai
- Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| |
Collapse
|
18
|
Hamid S, Nasir MU, So A, Andrews G, Nicolaou S, Qamar SR. Clinical Applications of Dual-Energy CT. Korean J Radiol 2021; 22:970-982. [PMID: 33856133 PMCID: PMC8154785 DOI: 10.3348/kjr.2020.0996] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 11/16/2020] [Accepted: 11/22/2020] [Indexed: 01/05/2023] Open
Abstract
Dual-energy CT (DECT) provides insights into the material properties of tissues and can differentiate between tissues with similar attenuation on conventional single-energy imaging. In the conventional CT scanner, differences in the X-ray attenuation between adjacent structures are dependent on the atomic number of the materials involved, whereas in DECT, the difference in the attenuation is dependent on both the atomic number and electron density. The basic principle of DECT is to obtain two datasets with different X-ray energy levels from the same anatomic region and material decomposition based on attenuation differences at different energy levels. In this article, we discuss the clinical applications of DECT and its potential robust improvements in performance and postprocessing capabilities.
Collapse
Affiliation(s)
- Saira Hamid
- Department of Radiology, University of British Columbia Hospital, University of British Columbia, Vancouver, Canada.
| | - Muhammad Umer Nasir
- Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, Vancouver, Canada
| | - Aaron So
- Department of Medical Biophyics, Schulich School of Medicine and Dentistry Western University London, Ontario, Canada
| | - Gordon Andrews
- Department of Radiology, University of British Columbia Hospital, University of British Columbia, Vancouver, Canada
| | - Savvas Nicolaou
- Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, Vancouver, Canada
| | - Sadia Raheez Qamar
- Department of Medical Imaging, Sunnybrook Hospital, University of Toronto, Toronto, Canada
| |
Collapse
|
19
|
Abstract
Dual-energy CT (DECT) overcomes several limitations of conventional single-energy CT (SECT) for the evaluation of gastrointestinal diseases. This article provides an overview of practical aspects of the DECT technology and acquisition protocols, reviews existing clinical applications, discusses current challenges, and describes future directions, with a focus on gastrointestinal imaging. A head-to-head comparison of technical specifications among DECT scanner implementations is provided. Energy- and material-specific DECT image reconstructions enable retrospective (i.e., after examination acquisition) image quality adjustments that are not possible using SECT. Such adjustments may, for example, correct insufficient contrast bolus or metal artifacts, thereby potentially avoiding patient recalls. A combination of low-energy monochromatic images, iodine maps, and virtual unenhanced images can be included in protocols to improve lesion detection and disease characterization. Relevant literature is reviewed regarding use of DECT for evaluation of the liver, gallbladder, pancreas, and bowel. Challenges involving cost, workflow, body habitus, and variability in DECT measurements are considered. Artificial intelligence and machine-learning image reconstruction algorithms, PACS integration, photon-counting hardware, and novel contrast agents are expected to expand the multienergy capability of DECT and further augment its value.
Collapse
|
20
|
Thiravit S, Brunnquell C, Cai LM, Flemon M, Mileto A. Use of dual-energy CT for renal mass assessment. Eur Radiol 2020; 31:3721-3733. [PMID: 33210200 DOI: 10.1007/s00330-020-07426-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 08/11/2020] [Accepted: 10/14/2020] [Indexed: 12/22/2022]
Abstract
Although dual-energy CT (DECT) may prove useful in a variety of abdominal imaging tasks, renal mass evaluation represents the area where this technology can be most impactful in abdominal imaging compared to routinely performed contrast-enhanced-only single-energy CT exams. DECT post-processing techniques, such as creation of virtual unenhanced and iodine density images, can help in the characterization of incidentally discovered renal masses that would otherwise remain indeterminate based on post-contrast imaging only. The purpose of this article is to review the use of DECT for renal mass assessment, including its benefits and existing limitations. KEY POINTS: • If DECT is selected as the scanning mode for most common abdominal protocols, many incidentally found renal masses can be fully triaged within the same exam. • Virtual unenhanced and iodine density DECT images can provide additional information when renal masses are discovered in the post-contrast-only setting. • For renal mass evaluation, virtual unenhanced and iodine density DECT images should be interpreted side-by-side to troubleshoot pitfalls that can potentially lead to erroneous interpretation.
Collapse
Affiliation(s)
- Shanigarn Thiravit
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA.,Division of Diagnostic Radiology, Department of Radiology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Christina Brunnquell
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Larry M Cai
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Mena Flemon
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
| | - Achille Mileto
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA.
| |
Collapse
|
21
|
Dual-energy CT in diffuse liver disease: is there a role? Abdom Radiol (NY) 2020; 45:3413-3424. [PMID: 32772121 DOI: 10.1007/s00261-020-02702-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 07/19/2020] [Accepted: 07/30/2020] [Indexed: 12/12/2022]
Abstract
Dual-energy CT (DECT) can be defined as the use of two different energy levels to identify and quantify material composition. Since its inception, DECT has benefited from remarkable improvements in hardware and clinical applications. DECT enables accurate identification and quantification of multiple materials, including fat, iron, and iodine. As a consequence, multiple studies have investigated the potential role of DECT in the assessment of diffuse liver diseases. While this role is evolving, this article aims to review the most relevant literature on use of DECT for assessment of diffuse liver diseases. Moreover, the basic concepts on DECT techniques, types of image reconstruction, and DECT-dedicated software will be described, focusing on the areas that are most relevant for the evaluation of diffuse liver diseases. Also, we will review the evidence of added value of DECT in detection and assessment of hepatocellular carcinoma which is a known risk in patients with diffuse liver disease.
Collapse
|
22
|
Xu JJ, Taudorf M, Ulriksen PS, Achiam MP, Resch TA, Nielsen MB, Lönn LB, Hansen KL. Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review. Diagnostics (Basel) 2020; 10:diagnostics10100814. [PMID: 33066281 PMCID: PMC7602017 DOI: 10.3390/diagnostics10100814] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 10/04/2020] [Accepted: 10/07/2020] [Indexed: 12/15/2022] Open
Abstract
Dual-energy computed tomography (DECT) can estimate tissue vascularity and perfusion via iodine quantification. The aim of this systematic review was to outline current and emerging clinical applications of iodine quantification within the gastrointestinal tract using DECT. The search was conducted with three databases: EMBASE, Pubmed and The Cochrane Library. This identified 449 studies after duplicate removal. From a total of 570 selected studies, 30 studies were enrolled for the systematic review. The studies were categorized into four main topics: gastric tumors (12 studies), colorectal tumors (8 studies), Crohn’s disease (4 studies) and miscellaneous applications (6 studies). Findings included a significant difference in iodine concentration (IC) measurements in perigastric fat between T1–3 vs. T4 stage gastric cancer, poorly and well differentiated gastric and colorectal cancer, responders vs. non-responders following chemo- or chemoradiotherapy treatment among cancer patients, and a positive correlation between IC and Crohn’s disease activity. In conclusion, iodine quantification with DECT may be used preoperatively in cancer imaging as well as for monitoring treatment response. Future studies are warranted to evaluate the capabilities and limitations of DECT in splanchnic flow.
Collapse
Affiliation(s)
- Jack Junchi Xu
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Correspondence:
| | - Mikkel Taudorf
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Peter Sommer Ulriksen
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Michael Patrick Achiam
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Department of Vascular Surgery, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark
| | - Timothy Andrew Resch
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Department of Clinical Medicine, University of Copenhagen, 2100 Copenhagen, Denmark
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Lars Birger Lönn
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| |
Collapse
|
23
|
Noda Y, Goshima S, Kaga T, Ando T, Miyoshi T, Kawai N, Kawada H, Tanahashi Y, Matsuo M. Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT. Clin Radiol 2020; 75:320.e17-320.e23. [DOI: 10.1016/j.crad.2019.11.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 11/20/2019] [Indexed: 11/17/2022]
|
24
|
Albrecht MH, Vogl TJ, Martin SS, Nance JW, Duguay TM, Wichmann JL, De Cecco CN, Varga-Szemes A, van Assen M, Tesche C, Schoepf UJ. Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT. Radiology 2019; 293:260-271. [DOI: 10.1148/radiol.2019182297] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
25
|
Kang HJ, Lee JM, Lee SM, Yang HK, Kim RH, Nam JG, Karnawat A, Han JK. Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom. BMC Med Imaging 2019; 19:76. [PMID: 31462212 PMCID: PMC6714289 DOI: 10.1186/s12880-019-0367-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 08/05/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Dual-layer spectral detector CT (SDCT) may provide several theoretical advantages over pre-existing DECT approaches in terms of adjustment-free sampling number and dose modulation, beam hardening correction, and production spectral images by post-processing. In addition, by adopting noise reduction algorithm, high contrast resolution was expected even in low keV level. We surmised that this improvement would be beneficial to obese people. Therefore, our aim of study is to compare image quality of virtual monochromatic spectral images (VMI) and polychromatic images reconstructed from SDCT with different body size and radiation dose using anthropomorphic liver phantom. METHODS One small and one large size of body phantoms, each containing eight (four high- and four low-contrast) simulated focal liver lesions (FLLs) were scanned by SDCT (at 120 kVp) using different Dose Right Indexes (DRIs). VMI were reconstructed from spectral base images from 40 keV to 200 keV. Hybrid iterative reconstruction (iDose4) was used for polychromatic image reconstruction. Image noise and contrast to noise ratio (CNR) were compared. Five radiologists independently rated lesion conspicuity, diagnostic acceptability and subjective noise level in every image sets, and determined optimal keV level in VMI. RESULTS Compare with conventional polychromatic images, VMI showed superior CNR at low keV level regardless of phantom size at every examined DRIs (Ps < 0.05). As body size increased, VMI had more gradual CNR decrease and noise increase than conventional polychromatic images. For low contrast FLLs in large phantom, lesion conspicuities at low radiation dose levels (DRI 16 and 19) were significantly increased in VMI (Ps < 0.05). Subjective image noise and diagnostic acceptabilities were significantly improved at VMI in both phantom size. CONCLUSIONS VMI of dual-layer spectral detector CT with noise reduction algorithm provides improved CNR, noise reduction, and better subjective image quality in imaging of obese simulated liver phantom compared with polychromatic images. This may hold promise for improving detection of liver lesions and improved imaging of obese patients.
Collapse
Affiliation(s)
- Hyo-Jin Kang
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
- Department of Radiology, Seoul National University College of Medicine, 101 Daehangno, Jongno-gu, Seoul, 03080 South Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
- Department of Radiology, Seoul National University College of Medicine, 101 Daehangno, Jongno-gu, Seoul, 03080 South Korea
- Institute of Radiation Medicine, Seoul National University College Medical Research Center, Seoul, 03080 South Korea
| | - Sang Min Lee
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang, 14068 South Korea
| | - Hyun Kyung Yang
- Department of Medical imaging, Toronto General hospital, Toronto, Canada
| | - Ri Hyeon Kim
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
| | - Ju Gang Nam
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
| | - Aruna Karnawat
- Department of Radiology, Nizam’s Institute of Medical Sciences, Hyderabad, 500082 India
| | - Joon Koo Han
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
- Department of Radiology, Seoul National University College of Medicine, 101 Daehangno, Jongno-gu, Seoul, 03080 South Korea
- Institute of Radiation Medicine, Seoul National University College Medical Research Center, Seoul, 03080 South Korea
| |
Collapse
|
26
|
Euler A, Solomon J, FitzGerald PF, Samei E, Nelson RC. Can Realistic Liver Tissue Surrogates Accurately Quantify the Impact of Reduced-kV Imaging on Attenuation and Contrast of Parenchyma and Lesions? Acad Radiol 2019; 26:640-650. [PMID: 30269958 DOI: 10.1016/j.acra.2018.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 07/28/2018] [Accepted: 08/08/2018] [Indexed: 10/28/2022]
Abstract
RATIONALE AND OBJECTIVES To assess if a liquid tissue surrogate for the liver (LTSL) can emulate contrast-enhanced liver parenchyma and lesions and quantify the impact of reduced-kV imaging as a function of lesion contrast, phase of enhancement, and phantom size. MATERIALS AND METHODS First, CT attenuation of LTSL- and water-iodine solutions were measured as a function of iodine concentration and tube potential. For each solution, the iodine concentration was determined to emulate liver parenchyma at 120 kV. CT attenuation for both solutions was predicted for different tube potentials and compared to published patient data. Second, liver parenchyma in late arterial phase (LA: +92 HU at 120 kV) and portal venous phase (PV: +112 HU at 120 kV) was emulated using LTSL-iodine and a two-size phantom. Fourteen setups of hyper- and hypoattenuating lesions (lesion-to-parenchyma contrast (CLP) = -50 to +50HU) were created. Each combination of CLP, phase, and size was imaged at 80, 100, 120, and 140 kV at constant radiation dose. CT attenuation, CLP, and lesion-to-parenchyma contrast-to-noise ratio (CNRLP) were assessed and compared to a theoretical model. RESULTS LTSL-iodine more accurately emulated the CT attenuation of liver parenchyma across different tube potentials compared to water-iodine solutions. The theoretical model was confirmed by the empirical measurements using LTSL-iodine solutions: attenuation, CLP, and CNRLP increased when the tube potential decreased (p < 0.001). This trend was independent of lesion contrast, phase, and size. The absolute improvement in CLP and CNRLP, however, was inversely related to the magnitude of CLP at 140kV. CONCLUSION LTSL accurately emulated the energy-dependent CT attenuation characteristics of contrast-enhanced liver parenchyma and lesions. The relative improvement in CLP and CNRLP by applying reduced-kV imaging was independent of lesion contrast, phase, and size while the absolute improvement decreased for low-contrast lesions.
Collapse
|
27
|
D'Angelo T, Cicero G, Mazziotti S, Ascenti G, Albrecht MH, Martin SS, Othman AE, Vogl TJ, Wichmann JL. Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications. Br J Radiol 2019; 92:20180546. [PMID: 30919651 DOI: 10.1259/bjr.20180546] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Dual energy CT (DECT) has evolved into a commonly applied imaging technique in clinical routine due to its unique post-processing opportunities for improved evaluation of all body areas. Reconstruction of virtual monoenergetic imaging (VMI) series has shown beneficial effects for both non-contrast and contrast-enhanced DECT due to the flexibility to calculate low-keV VMI reconstructions to increase contrast and iodine attenuation, or to compute high-keV VMI reconstructions to reduce beam-hardening artefacts. The goal of this review article is to explain the technical background of VMI and noise-optimized VMI+ algorithms and to give an overview of useful clinical applications of the VMI technique in DECT of various body regions.
Collapse
Affiliation(s)
- Tommaso D'Angelo
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy.,2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Giuseppe Cicero
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Silvio Mazziotti
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Giorgio Ascenti
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Moritz H Albrecht
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Simon S Martin
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Ahmed E Othman
- 3 Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen , Tübingen , Germany
| | - Thomas J Vogl
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Julian L Wichmann
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| |
Collapse
|
28
|
Virtual monoenergetic dual-energy CT for evaluation of hepatic and splenic lacerations. Emerg Radiol 2019; 26:419-425. [PMID: 30963313 DOI: 10.1007/s10140-019-01687-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2019] [Accepted: 03/21/2019] [Indexed: 12/13/2022]
Abstract
PURPOSE To evaluate the utility of virtual monoenergetic imaging in assessing hepatic and splenic lacerations and to determine the optimal energy level to maximize injury contrast-to-noise ratio. METHODS We retrospectively examined 49 contrast-enhanced abdominal CT studies performed on a dual-source dual-energy CT (DECT) scanner with reported liver and/or splenic lacerations. All studies included portal venous phase imaging acquired simultaneously at low (80 or 100 kVp) and high (140 kVp with tin filtration) energy levels. Conventional 120 kVp-equivalent images were generated for routine review by blending the low and high energy acquisitions. Virtual monoenergetic reconstructions were retrospectively generated in 10 keV increments from 40 to 90 keV. Liver or splenic laceration attenuation, background parenchymal attenuation, and noise were measured on each set of monoenergetic and conventional images. Injury-to-parenchyma contrast and contrast-to-noise ratios (CNR) were calculated. Differences between CNR of monoenergetic series and conventional images were assessed with a paired t test. RESULTS Liver laceration was identified in 28 patients, and splenic laceration in 22 patients. Background noise was lower at higher monoenergetic levels, with the lowest noise seen at 90 keV, less than that of conventional images (stddev 8.0 for 90 keV and 8.5 for conventional based on noise of uninjured liver/spleen parenchyma, p < 0.001). For both liver and splenic lacerations, injury-to-parenchyma contrast was greater at lower monoenergetic levels, with maximum at 40 keV. Contrast at 40-70 keV was significantly greater than that of conventional images (p < 0.001). Injury-to parenchyma CNR was also greater at 40-70 keV than that of conventional images and with statistical significance. CNR was highest at 40 keV for both liver (6.5 for 40 keV and 5.4 for conventional, p < 0.001) and splenic lacerations (7.5 vs. 5.8, p < 0.001). CONCLUSIONS DECT virtual monoenergetic imaging at low keV improves injury-to-parenchyma CNR of hepatic and splenic lacerations compared with traditional polyenergetic reconstructions. Specially, the optimal energy level for assessing both was 40 keV.
Collapse
|
29
|
Böning G, Feldhaus F, Adelt S, Kahn J, Fehrenbach U, Streitparth F. Clinical routine use of virtual monochromatic datasets based on spectral CT in patients with hypervascularized abdominal tumors - evaluation of effectiveness and efficiency. Acta Radiol 2019; 60:425-432. [PMID: 29950111 DOI: 10.1177/0284185118786077] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
BACKGROUND Virtual monochromatic images (VMI) generated using spectral computed tomography (CT) are promising recently available tools to improve diagnostic performance in oncologic patients. PURPOSE To investigate if virtual monochromatic datasets are suitable for clinical routine use in patients with hypervascularized abdominal tumors. MATERIAL AND METHODS A total of 41 patients with hypervascularized hepatocellular carcinoma (HCC), renal cell carcinoma (RCC), or neuroendocrine tumors (NET) were enrolled in the study; 451 CT series were analyzed. In an intra-individual study design, virtual monochromatic datasets of the arterial phase of each scan were computed. Image quality was assessed objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) and subjectively by using five-point Likert-scales. The volume CT dose index (CTDIvol) was taken from each radiation dose report. The increase in reading time was estimated from the increase in the number of images. RESULTS Intra-individual comparison of the spectral mode in the arterial phase with the portal venous phase revealed no significant increase in the applied dose. SNR, CNRtumor-to-liver , and CNRtumor-to-muscle were significantly increased by lowering virtual monochromatic energy. Subjective image quality scores revealed an increase of contrast in low energy datasets, resulting in significantly higher diagnostic confidence, but an increased image noise at low energies. While diagnostic confidence improved, taking all datasets into account resulted in a significantly longer estimated reading time. CONCLUSION In clinical practice, the use of low energy VMI improved diagnostic confidence without a significant increase in dose. The main disadvantage is a decrease in efficiency due to longer reading times.
Collapse
Affiliation(s)
- Georg Böning
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Felix Feldhaus
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Sebastian Adelt
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Johannes Kahn
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Uli Fehrenbach
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Florian Streitparth
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
30
|
Optimal window settings in single-source dual-energy computed tomography of the abdomen. Eur J Radiol 2018; 109:204-209. [DOI: 10.1016/j.ejrad.2018.10.012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 10/11/2018] [Accepted: 10/15/2018] [Indexed: 01/09/2023]
|
31
|
Lee SK, Jung JY, Jee WH, Lee JJ, Park SH. Combining non-contrast and dual-energy CT improves diagnosis of early gout. Eur Radiol 2018; 29:1267-1275. [PMID: 30225600 DOI: 10.1007/s00330-018-5716-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Revised: 07/17/2018] [Accepted: 08/14/2018] [Indexed: 12/27/2022]
Abstract
OBJECTIVES To determine the incremental value of non-contrast CT (NCCT) on dual-energy CT (DECT) in symptomatic first metatarsophalangeal (MTP) joints in early gout. METHODS One hundred and fifteen painful joints were consecutively enrolled and gout was diagnosed based on the 2015 EULAR/ACR criteria and/or arthrocentesis. Two readers independently evaluated DECT alone and combined NCCT and DECT (NCCT+DECT) based on four semiquantitative scales. Sensitivities and specificities were compared using McNemar's test. AUC was compared. RESULTS Of the 115 joints, 72 were defined as an early gout group and 43 as a gout-negative group after exclusion. The sensitivity and specificity for the early gout group on DECT alone were as followed: reader 1 - 52.8% and 100.0% and reader 2 - 51.4% and 100.0%. NCCT+DECT results were as follows: reader 1 - 79.2% and 93.0% and reader 2 - 79.2% and 95.3%. AUC was significantly higher in NCCT+DECT compared to that in DECT alone for the early gout group (0.888 vs. 0.774 for reader 1, p = 0.0004; 0.896 vs. 0.816 for reader 2, p = 0.0142). The false-negative cases on DECT occurred more frequently with the first-onset gout, and tended to be affected by a longer duration of symptoms in the post-hoc analysis. CONCLUSION The combined analysis of NCCT and DECT improves diagnostic capabilities in symptomatic early gout involving the first MTP joint. KEY POINTS • MSU crystal depositions in early gout may be seen on non-contrast CT, while still being undetectable by DECT. • Combining non-contrast CT and DECT improves detection of early gout. • False negatives of DECT are more common than previously reported in cases of first-onset gout.
Collapse
Affiliation(s)
- Seul Ki Lee
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
- Department of Radiology, Dongguk University Ilsan Hospital, Gyenggi-do, 10326, Republic of Korea
| | - Joon-Yong Jung
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.
| | - Won-Hee Jee
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Jennifer Jooha Lee
- Division of Rheumatology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Sung-Hwan Park
- Division of Rheumatology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| |
Collapse
|
32
|
Vernuccio F, Meyer M, Mileto A, Marin D. Use of Dual-Energy Computed Tomography for Evaluation of Genitourinary Diseases. Urol Clin North Am 2018; 45:297-310. [PMID: 30031456 DOI: 10.1016/j.ucl.2018.03.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Since its clinical inception a decade ago, dual-energy computed tomography has expanded the array of computed tomography imaging tools available to the practicing abdominal radiologist. Of note, diagnostic solutions for imaging-based evaluation of genitourinary diseases, foremost kidney calculi and renal tumors characterization, represent the apogee applications of dual-energy computed tomography in abdominal imaging. This article reviews clinical applications of dual-energy computed tomography for the assessment of genitourinary diseases.
Collapse
Affiliation(s)
- Federica Vernuccio
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA; Section of Radiology -Di.Bi.Med., University Hospital "Paolo Giaccone", University of Palermo, Via del Vespro 129, 90127, Palermo, Italy
| | - Mathias Meyer
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA
| | - Achille Mileto
- Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 Northeast Pacific Street, Seattle, WA 98195, USA
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA.
| |
Collapse
|
33
|
Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study. Abdom Radiol (NY) 2018; 43:1404-1412. [PMID: 28983661 DOI: 10.1007/s00261-017-1327-9] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE Single-energy low tube potential (SE-LTP) and dual-energy virtual monoenergetic (DE-VM) CT images both increase the conspicuity of hepatic lesions by increasing iodine signal. Our purpose was to compare the conspicuity of proven liver lesions, artifacts, and radiologist preferences in dose-matched SE-LTP and DE-VM images. METHODS Thirty-one patients with 72 proven liver lesions (21 benign, 51 malignant) underwent full-dose contrast-enhanced dual-energy CT (DECT). Half-dose images were obtained using single tube reconstruction of the dual-source SE-LTP projection data (80 or 100 kV), and by inserting noise into dual-energy projection data, with DE-VM images reconstructed from 40 to 70 keV. Three blinded gastrointestinal radiologists evaluated half-dose SE-LTP and DE-VM images, ranking and grading liver lesion conspicuity and diagnostic confidence (4-point scale) on a per-lesion basis. Image quality (noise, artifacts, sharpness) was evaluated, and overall image preference was ranked on per-patient basis. Lesion-to-liver contrast-to-noise ratio (CNR) was compared between techniques. RESULTS Mean lesion size was 1.5 ± 1.2 cm. Across the readers, the mean conspicuity ratings for 40, 45, and 50 keV half-dose DE-VM images were superior compared to other half-dose image sets (p < 0.0001). Per-lesion diagnostic confidence was similar between half-dose SE-LTP compared to half-dose DE-VM images (p ≥ 0.05; 1.19 vs. 1.24-1.32). However, SE-LTP images had less noise and artifacts and were sharper compared to DE-VM images less than 70 keV (p < 0.05). On a per-patient basis, radiologists preferred SE-LTP images the most and preferred 40-50 keV the least (p < 0.0001). Lesion CNR was also higher in SE-LTP images than DE-VM images (p < 0.01). CONCLUSION For the same applied dose level, liver lesions were more conspicuous using DE-VM compared to SE-LTP; however, SE-LTP images were preferred more than any single DE-VM energy level, likely due to lower noise and artifacts.
Collapse
|
34
|
De Cecco CN, Caruso D, Schoepf UJ, De Santis D, Muscogiuri G, Albrecht MH, Meinel FG, Wichmann JL, Burchett PF, Varga-Szemes A, Sheafor DH, Hardie AD. A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions. Eur Radiol 2018; 28:3393-3404. [PMID: 29460075 DOI: 10.1007/s00330-018-5313-6] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2017] [Revised: 12/05/2017] [Accepted: 01/03/2018] [Indexed: 01/24/2023]
Abstract
OBJECTIVES To assess the image quality and diagnostic accuracy of a noise-optimized virtual monoenergetic imaging (VMI+) algorithm compared with standard virtual monoenergetic imaging (VMI) and linearly-blended (M_0.6) reconstructions for the detection of hypervascular liver lesions in dual-energy CT (DECT). METHODS Thirty patients who underwent clinical liver MRI were prospectively enrolled. Within 60 days of MRI, arterial phase DECT images were acquired on a third-generation dual-source CT and reconstructed with M_0.6, VMI and VMI+ algorithms from 40 to 100 keV in 5-keV intervals. Liver parenchyma and lesion contrast-to-noise-ratios (CNR) were calculated. Two radiologists assessed image quality. Lesion sensitivity, specificity and area under the receiver operating characteristic curves (AUCs) were calculated for the three algorithms with MRI as the reference standard. RESULTS VMI+ datasets from 40 to 60 keV provided the highest liver parenchyma and lesion CNR (p ≤0.021); 50 keV VMI+ provided the highest subjective image quality (4.40±0.54), significantly higher compared to VMI and M_0.6 (all p <0.001), and the best diagnostic accuracy in < 1-cm diameter lesions (AUC=0.833 vs. 0.777 and 0.749, respectively; p ≤0.003). CONCLUSIONS 50-keV VMI+ provides superior image quality and diagnostic accuracy for the detection of hypervascular liver lesions with a diameter < 1cm compared to VMI or M_0.6 reconstructions. KEY POINTS • Low-keV VMI+ are characterized by higher contrast resulting from maximum iodine attenuation. • VMI+ provides superior image quality compared with VMI or M_0.6. • 50-keV_VMI+ provides higher accuracy for the detection of hypervascular liver lesions < 1cm.
Collapse
Affiliation(s)
- Carlo N De Cecco
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Damiano Caruso
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Radiological Sciences, Oncological and Pathological Sciences University of Rome "Sapienza", Latina, Italy
| | - U Joseph Schoepf
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.
| | - Domenico De Santis
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Radiological Sciences, Oncological and Pathological Sciences University of Rome "Sapienza", Latina, Italy
| | - Giuseppe Muscogiuri
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Clinical and Molecular Medicine, University of Rome "Sapienza", Rome, Italy
| | - Moritz H Albrecht
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Felix G Meinel
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany
| | - Julian L Wichmann
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Philip F Burchett
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Akos Varga-Szemes
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Douglas H Sheafor
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Andrew D Hardie
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| |
Collapse
|
35
|
Toia GV, Kim S, Dighe MK, Mileto A. Dual-Energy Computed Tomography in Body Imaging. Semin Roentgenol 2018; 53:132-146. [PMID: 29861005 DOI: 10.1053/j.ro.2018.02.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Giuseppe V Toia
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Sooah Kim
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Manjiri K Dighe
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Achille Mileto
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195.
| |
Collapse
|
36
|
Multi-detector CT: Liver protocol and recent developments. Eur J Radiol 2017; 97:101-109. [PMID: 29153359 DOI: 10.1016/j.ejrad.2017.10.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2017] [Revised: 10/18/2017] [Accepted: 10/26/2017] [Indexed: 02/07/2023]
Abstract
Multi-detector computed tomography is today the workhorse in the evaluation of the vast majority of patients with known or suspected liver disease. Reasons for that include widespread availability, robustness and repeatability of the technique, time-efficient image acquisitions of large body volumes, high temporal and spatial resolution as well as multiple post-processing capabilities. However, as the technique employs ionizing radiation and intravenous iodine-based contrast media, the associated potential risks have to be taken into account. In this review article, liver protocols in clinical practice are discussed with emphasis on optimisation strategies. Furthermore, recent developments such as perfusion CT and dual-energy CT and their applications are presented.
Collapse
|
37
|
Selection of optimal tube potential settings for dual-energy CT virtual mono-energetic imaging of iodine in the abdomen. Abdom Radiol (NY) 2017; 42:2289-2296. [PMID: 28365785 DOI: 10.1007/s00261-017-1122-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE To determine the appropriate tube potential settings for dual-source, dual-energy data acquisition across a range of phantom sizes, and to determine the optimal photon energies for virtual mono-energetic imaging. METHODS Water phantoms (15-50-cm wide) containing an iodine test object were scanned on a third-generation dual-source CT scanner using all available tube potential pairs. Virtual mono-energetic images at 40, 50, 60, and 70 keV were produced using Mono-energetic Plus. To determine the practical operating parameters for the evaluated CT system, data exclusions were made based on water CT number accuracy, artifacts, and using a noise constraint. Image quality metrics were measured and compared. RESULTS Excluded tube potential pairs were identified; these were generally at low tube potentials for the low-energy beam and low photon energies. For non-excluded conditions, the highest CNR was obtained using the 70/150Sn setting in phantoms ≤35 cm at 40 keV. CONCLUSIONS 70/150Sn provided optimal iodine CNR below 40 cm lateral phantom width at 40 keV, while 90/150Sn allowed acceptable image quality in phantoms >40-cm wide at or above 60 keV.
Collapse
|
38
|
Okamura T, Yamada Y, Yamada M, Yamazaki A, Shiraga N, Jinzaki M. Image quality of virtual monochromatic images obtained using 320-detector row CT: A phantom study evaluating the effects of iterative reconstruction and body size. Eur J Radiol 2017; 95:212-221. [PMID: 28987670 DOI: 10.1016/j.ejrad.2017.08.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2017] [Revised: 07/09/2017] [Accepted: 08/15/2017] [Indexed: 12/21/2022]
Abstract
OBJECTIVES To compare the image quality between virtual monochromatic spectral (VMS) images obtained using 320-row detector CT and polychromatic 120-kVp images reconstructed with or without iterative reconstruction using various phantom sizes. MATERIALS AND METHODS Torso phantoms simulating three patient sizes and containing four syringes filled with water or different contrast media (5, 10, 15mgI/mL15mgI/ml) were used. The phantoms were scanned using dual-energy (80/135-kVp) and single-energy (120-kVp) protocols at different settings (20mGy, 12mGy, and 6mGy). VMS images were generated at 1-keV intervals (range, 35-135keV). Both the VMS images and the single-energy 120-kVp images were reconstructed using filtered back projection (FBP) and adaptive iterative dose reduction 3D (AIDR-3D). The signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were assessed. RESULTS Using FBP reconstruction, the SNR and CNR of the VMS images were lower than or similar to those of the 120-kVp images for most dose settings. Using AIDR-3D reconstruction, however, the 70-keV VMS images had higher SNRs and CNRs than the 120-kVp images at most settings. CONCLUSIONS The image quality of VMS images with FBP reconstruction tended to be lower than that of the 120-kVp images. With the use of AIDR-3D, however, approximately 70-keV VMS images had a higher image quality than the 120-kVp images.
Collapse
Affiliation(s)
- Teppei Okamura
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Yoshitake Yamada
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Minoru Yamada
- Research Park, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Akihisa Yamazaki
- Department of Radiological Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Nobuyuki Shiraga
- Department of Radiology, Toho University Medical Center Omori Hospital, 6-11-1 Omori-nishi, Ota-ku, Tokyo, 143-8541, Japan.
| | - Masahiro Jinzaki
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| |
Collapse
|
39
|
Parakh A, Baliyan V, Sahani DV. Dual-Energy CT in Focal and Diffuse Liver Disease. CURRENT RADIOLOGY REPORTS 2017. [DOI: 10.1007/s40134-017-0226-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
40
|
Kim JE, Kim HO, Bae K, Cho JM, Choi HC, Choi DS. Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters. Eur J Radiol 2017. [PMID: 28624012 DOI: 10.1016/j.ejrad.2017.05.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
PURPOSE To investigate the use of dual source dual-energy CT (DECT) quantitative parameters compared with the use of conventional CT for differentiating small (≤3cm) intrahepatic mass-forming cholangiocarcinoma (IMCC) from small liver abscess (LA) during the portal venous phase (PVP). MATERIAL AND METHODS In this institutional review board-approved, retrospective study, 64 patients with IMCCs and 52 patients with LAs who were imaged in PVP using dual-energy mode were included retrospectively. A radiologist drew circular regions of interest in the lesion on the virtual monochromatic images (VMI), color-coded iodine overlay images, and linear blending images with a linear blending ratio of 0.3 to obtain CT value, its standard deviation, slope (k) of spectral curve and normalized iodine concentration (NIC). Two radiologists assessed lesion type on the basis of qualitative CT imaging features. RESULTS CT values on VMI at 50-130keV (20keV-interval), k, and NIC values were significantly higher in IMCCs than in LAs (p<0.0001). The best single parameter for differentiating IMCC from LA was CT value at 90keV, with sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 89.1%, 86.5%, 87.9%, 89.1%, and 86.5%, respectively. The best combination of parameters was CT value at 90keV, k, and NIC, with values of 87.5%, 84.6%, 83.6%, 87.5%, and 84.6%, respectively. Compared with CT value at linear blending images, CT value at 90keV showed greater sensitivity (89.1% vs 60.9%, p<0.0001) and similar specificity (86.5% vs 84.6%, p=1.0000), and combined CT value at 90keV, k, and NIC showed greater sensitivity (87.5% vs 60.9%, p<0.0001) and similar specificity (84.6% vs 84.6%, p=1.0000). Compared with qualitative analysis, CT value at 90keV showed greater sensitivity (89.1% vs 65.6%, p=0.0059) and specificity (86.5% vs 69.2%, p=0.0352), and combined CT value at 90keV, k, and NIC showed greater sensitivity (87.5% vs 65.6%, p=0.0094) and similar specificity (84.6% vs 69.2%, p >0.05). CONCLUSION Quantitative analysis of dual source dual-energy CT quantitative parameters showed greater accuracy than quantitative and qualitative analyses of conventional CT for differentiating small IMCCs from small LAs on single PVP scan.
Collapse
Affiliation(s)
- Ji Eun Kim
- Department of Radiology, Gyeongsang National University School of Medicine, 79 Gangnam-ro, Jinju 52727, Republic of Korea.
| | - Hyun Ok Kim
- Department of Internal Medicine, Gyeongsang National University School of Medicine, 79 Gangnam-ro, Jinju 52727, Republic of Korea.
| | - Kyungsoo Bae
- Department of Radiology, Gyeongsang National University School of Medicine, 79 Gangnam-ro, Jinju 52727, Republic of Korea.
| | - Jae Min Cho
- Department of Radiology, Gyeongsang National University School of Medicine, 79 Gangnam-ro, Jinju 52727, Republic of Korea.
| | - Ho Cheol Choi
- Department of Radiology, Gyeongsang National University School of Medicine, 79 Gangnam-ro, Jinju 52727, Republic of Korea.
| | - Dae Seob Choi
- Department of Radiology, Gyeongsang National University School of Medicine, 79 Gangnam-ro, Jinju 52727, Republic of Korea.
| |
Collapse
|
41
|
Impact of low-energy CT imaging on selection of positive oral contrast media concentration. Abdom Radiol (NY) 2017; 42:1298-1309. [PMID: 27933477 DOI: 10.1007/s00261-016-0993-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
OBJECTIVES To determine to what extent low-energy CT imaging affects attenuation of gastrointestinal tract (GIT) opacified with positive oral contrast media (OCM). Second, to establish optimal OCM concentrations for low-energy diagnostic CT exams. METHODS One hundred patients (38 men and 62 women; age 62 ± 11 years; BMI 26 ± 5) with positive OCM-enhanced 120-kVp single-energy CT (SECT), and follow-up 100-kVp acquisitions (group A; n = 50), or 40-70-keV reconstructions from rapid kV switching-single-source dual-energy CT (ssDECT) (group B; n = 50) were included. Luminal attenuation from different GIT segments was compared between exams. Standard dose of three OCM and diluted solutions (75%, 50%, and 25% concentrations) were introduced serially in a gastrointestinal phantom and scanned using SECT (120, 100, and 80 kVp) and DECT (80/140 kVp) acquisitions on a ssDECT scanner. Luminal attenuation was obtained on SECT and DECT images (40-70 keV), and compared to 120-kVp scans with standard OCM concentrations. RESULTS Luminal attenuation was higher on 100-kVp (328 HU) and on 40-60-keV images (410-924 HU) in comparison to 120-kVp scans (298 HU) in groups A and B (p < 0.05). Phantom: There was an inverse correlation between luminal attenuation and X-ray energy, increasing up to 527 HU on low-kVp and 999 HU on low-keV images (p < 0.05). 25% and 50% diluted OCM solutions provided similar or higher attenuation than 120 kVp, at low kVp and keV, respectively. CONCLUSIONS Low-energy CT imaging increases the attenuation of GIT opacified with positive OCM, permitting reduction of 25%-75% OCM concentration.
Collapse
|
42
|
Dual-energy CT workflow: multi-institutional consensus on standardization of abdominopelvic MDCT protocols. Abdom Radiol (NY) 2017; 42:676-687. [PMID: 27888303 DOI: 10.1007/s00261-016-0966-6] [Citation(s) in RCA: 61] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
PURPOSE To standardize workflow for dual-energy computed tomography (DECT) involving common abdominopelvic exam protocols. MATERIALS AND METHODS 9 institutions (4 rsDECT, 1 dsDECT, 4 both) with 32 participants [average # years (range) in practice and DECT experience, 12.3 (1-35) and 4.6 (1-14), respectively] filled out a single survey (n = 9). A five-point agreement scale (0, 1, 2, 3, 4-contra-, not, mildly, moderately, strongly indicated, respectively) and utilization scale (0-not performing and shouldn't; 1-performing but not clinically useful; 2-performing but not sure if clinically useful; 3-not performing it but would like to; 4-performing and clinically useful) were used. Consensus was considered with a score of ≥2.5. Survey results were discussed over three separate live webinar sessions. RESULTS 5/9 (56%) institutions exclude large patients from DECT. 2 (40%) use weight, 2 (40%) use transverse dimension, and 1 (20%) uses both. 7/9 (78%) use 50 keV for low and 70 keV for medium monochromatic reconstructed images. DECT is indicated for dual liver [agreement score (AS) 3.78; utilization score (US) 3.22] and dual pancreas in the arterial phase (AS 3.78; US 3.11), mesenteric ischemia/gastrointestinal bleeding in both the arterial and venous phases (AS 2.89; US 2.79), RCC exams in the arterial phase (AS 3.33; US 2.78), and CT urography in the nephrographic phase (AS 3.11; US 2.89). DECT for renal stone and certain single-phase exams is indicated (AS 3.00). CONCLUSIONS DECT is indicated during the arterial phase for multiphasic abdominal exams, nephrographic phase for CTU, and for certain single-phase and renal stone exams.
Collapse
|
43
|
Uhrig M, Simons D, Bonekamp D, Schlemmer HP. Improved detection of melanoma metastases by iodine maps from dual energy CT. Eur J Radiol 2017; 90:27-33. [PMID: 28583644 DOI: 10.1016/j.ejrad.2017.02.024] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 12/29/2016] [Accepted: 02/15/2017] [Indexed: 01/01/2023]
Abstract
OBJECTIVE Metastatic disease in melanoma has an unpredictable nature with deposits in rare locations such as musculature. Dual energy CT (DECT) provides high contrast-visualization of enhancement by using spectral properties of iodine. Purpose of this study was to evaluate whether iodine maps from DECT improve lesion detection in staging examinations of melanoma patients. METHODS This retrospective study was approved by IRB and written informed consent was obtained from all patients. 75 contrast-enhanced DECT scans (thorax and abdomen) from 75 melanoma patients (n=69 stage IV; n=6 stage III) were analysed. For each patient, conventional CT and iodine maps were reviewed independently by two radiologists. The number of lesions detected by reviewing the iodine maps following conventional CT was recorded. Unweighted Cohens Kappa coefficient (κ) was used for concordance analysis, Wilcoxon test for comparing lesion detection rates. RESULTS In 26 patients, at least one reader found additional lesions on iodine maps (inter-reader agreement 89%, κ=0.74 (0.742-0.747)). Compared to grey-scale images, mean detection rate for metastases improved from 86% (range 82-90) to 94% (90-99%) (p≤0.01), for muscle metastases from 8% (8-8%) to 99% (98-100%) (p≤0.06). Findings included 2 pulmonary emboli. CONCLUSION Iodine maps from DECT improve detection of metastases, especially muscle metastases, and relevant findings in staging examinations of melanoma patients.
Collapse
Affiliation(s)
- Monika Uhrig
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany.
| | - David Simons
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| | - David Bonekamp
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| | - Heinz-Peter Schlemmer
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| |
Collapse
|
44
|
Abstract
Reignited by innovations in scanner engineering and software design, dual-energy computed tomography (CT) has come back into the clinical radiology arena in the last decade. Possibilities for noninvasive in vivo characterization of genitourinary disease, especially for renal stones and renal masses, have become the pinnacle offerings of dual-energy CT for body imaging in clinical practice. This article renders a state-of-the-art review on clinical applications of dual-energy CT in genitourinary imaging.
Collapse
Affiliation(s)
- Achille Mileto
- Department of Radiology, University of Washington School of Medicine, Box 357115, 1959 Northeast Pacific Street, Seattle, WA 98195, USA
| | - Daniele Marin
- Department of Radiology, Duke University Medical Center, Box 3808 Erwin Road, Durham, NC 27710, USA.
| |
Collapse
|
45
|
Use of a Noise Optimized Monoenergetic Algorithm for Patient-Size Independent Selection of an Optimal Energy Level During Dual-Energy CT of the Pancreas. J Comput Assist Tomogr 2017; 41:39-47. [PMID: 27560021 DOI: 10.1097/rct.0000000000000492] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To investigate the impact of a second-generation noise-optimized monoenergetic algorithm on selection of the optimal energy level, image quality, and effect of patient body habitus for dual-energy multidetector computed tomography of the pancreas. MATERIALS AND METHODS Fifty-nine patients (38 men, 21 women) underwent dual-energy multidetector computed tomography (80/Sn140 kV) in the pancreatic parenchymal phase. Image data sets, at energy levels ranging from 40 to 80 keV (in 5-keV increments), were reconstructed using first-generation and second-generation noise-optimized monoenergetic algorithm. Noise, pancreatic contrast-to-noise ratio (CNRpancreas), and CNR with a noise constraint (CNRNC) were calculated and compared among the different reconstructed data sets. Qualitative assessment of image quality was performed by 3 readers. RESULTS For all energy levels below 70 keV, noise was significantly lower (P ≤ 0.05) and CNRpancreas significantly higher (P < 0.001), with the second-generation monoenergetic algorithm. Furthermore, the second-generation algorithm was less susceptible to variability related to patient body habitus in the selection of the optimal energy level. The maximal CNRpancreas occurred at 40 keV in 98% (58 of 59) of patients with the second-generation monoenergetic algorithm. However, the CNRNC and readers' image quality scores showed that, even with a second-generation monoenergetic algorithm, higher reconstructed energy levels (60-65 keV) represented the optimal energy level. CONCLUSIONS Second-generation noise-optimized monoenergetic algorithm can improve the image quality of lower-energy monoenergetic images of the pancreas, while decreasing the variability related to patient body habitus in selection of the optimal energy level.
Collapse
|
46
|
Can dual-energy computed tomography improve visualization of hypoenhancing liver lesions in portal venous phase? Assessment of advanced image-based virtual monoenergetic images. Clin Imaging 2017; 41:118-124. [DOI: 10.1016/j.clinimag.2016.10.015] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2016] [Revised: 09/28/2016] [Accepted: 10/17/2016] [Indexed: 11/18/2022]
|
47
|
Michalak G, Grimes J, Fletcher J, Halaweish A, Yu L, Leng S, McCollough C. Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging. Med Phys 2016; 43:513. [PMID: 26745944 DOI: 10.1118/1.4939128] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
PURPOSE The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. METHODS Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kV beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. RESULTS Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. CONCLUSIONS The authors' report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.
Collapse
Affiliation(s)
- Gregory Michalak
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905
| | - Joshua Grimes
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905
| | - Joel Fletcher
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905
| | | | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905
| | | |
Collapse
|
48
|
|
49
|
Adoption of Splenic Enhancement to Time and Trigger the Late Hepatic Arterial Phase During MDCT of the Liver: Proof of Concept and Clinical Feasibility. AJR Am J Roentgenol 2016; 207:310-20. [DOI: 10.2214/ajr.15.15808] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
50
|
Effect of a Noise-Optimized Second-Generation Monoenergetic Algorithm on Image Noise and Conspicuity of Hypervascular Liver Tumors: An In Vitro and In Vivo Study. AJR Am J Roentgenol 2016; 206:1222-32. [PMID: 27058192 DOI: 10.2214/ajr.15.15512] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study is to investigate whether the reduction in noise using a second-generation monoenergetic algorithm can improve the conspicuity of hypervascular liver tumors on dual-energy CT (DECT) images of the liver. MATERIALS AND METHODS An anthropomorphic liver phantom in three body sizes and iodine-containing inserts simulating hypervascular lesions was imaged with DECT and single-energy CT at various energy levels (80-140 kV). In addition, a retrospective clinical study was performed in 31 patients with 66 hypervascular liver tumors who underwent DECT during the late hepatic arterial phase. Datasets at energy levels ranging from 40 to 80 keV were reconstructed using first- and second-generation monoenergetic algorithms. Noise, tumor-to-liver contrast-to-noise ratio (CNR), and CNR with a noise constraint (CNRNC) set with a maximum noise increase of 50% were calculated and compared among the different reconstructed datasets. RESULTS The maximum CNR for the second-generation monoenergetic algorithm, which was attained at 40 keV in both phantom and clinical datasets, was statistically significantly higher than the maximum CNR for the first-generation monoenergetic algorithm (p < 0.001) or single-energy CT acquisitions across a wide range of kilovoltage values. With the second-generation monoenergetic algorithm, the optimal CNRNC occurred at 55 keV, corresponding to lower energy levels compared with first-generation algorithm (predominantly at 70 keV). Patient body size did not substantially affect the selection of the optimal energy level to attain maximal CNR and CNRNC using the second-generation monoenergetic algorithm. CONCLUSION A noise-optimized second-generation monoenergetic algorithm significantly improves the conspicuity of hypervascular liver tumors.
Collapse
|