1
|
Chen H, Fang Y, Gu J, Sun P, Yang L, Pan F, Wu H, Ye T. Dual-Layer Spectral Detector Computed Tomography Quantitative Parameters: A Potential Tool for Lymph Node Activity Determination in Lymphoma Patients. Diagnostics (Basel) 2024; 14:149. [PMID: 38248026 PMCID: PMC10814325 DOI: 10.3390/diagnostics14020149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 01/01/2024] [Accepted: 01/04/2024] [Indexed: 01/23/2024] Open
Abstract
Dual-energy CT has shown promising results in determining tumor characteristics and treatment effectiveness through spectral data by assessing normalized iodine concentration (nIC), normalized effective atomic number (nZeff), normalized electron density (nED), and extracellular volume (ECV). This study explores the value of quantitative parameters in contrast-enhanced dual-layer spectral detector CT (SDCT) as a potential tool for detecting lymph node activity in lymphoma patients. A retrospective analysis of 55 lymphoma patients with 289 lymph nodes, assessed through 18FDG-PET/CT and the Deauville five-point scale, revealed significantly higher values of nIC, nZeff, nED, and ECV in active lymph nodes compared to inactive ones (p < 0.001). Generalized linear mixed models showed statistically significant fixed-effect parameters for nIC, nZeff, and ECV (p < 0.05). The area under the receiver operating characteristic curve (AUROC) values of nIC, nZeff, and ECV reached 0.822, 0.845, and 0.811 for diagnosing lymph node activity. In conclusion, the use of g nIC, nZeff, and ECV as alternative imaging biomarkers to PET/CT for identifying lymph node activity in lymphoma holds potential as a reliable diagnostic tool that can guide treatment decisions.
Collapse
Affiliation(s)
- Hebing Chen
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue #1277, Wuhan 430022, China; (H.C.); (Y.F.); (J.G.); (L.Y.); (F.P.)
- Hubei Province Key Laboratory of Molecular Imaging, Jiefang Avenue #1277, Wuhan 430022, China
| | - Yuxiang Fang
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue #1277, Wuhan 430022, China; (H.C.); (Y.F.); (J.G.); (L.Y.); (F.P.)
- Hubei Province Key Laboratory of Molecular Imaging, Jiefang Avenue #1277, Wuhan 430022, China
| | - Jin Gu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue #1277, Wuhan 430022, China; (H.C.); (Y.F.); (J.G.); (L.Y.); (F.P.)
- Hubei Province Key Laboratory of Molecular Imaging, Jiefang Avenue #1277, Wuhan 430022, China
| | - Peng Sun
- Clinical & Technical Support, Philips Healthcare, Floor 7, Building 2, World Profit Center, Beijing 100000, China;
| | - Lian Yang
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue #1277, Wuhan 430022, China; (H.C.); (Y.F.); (J.G.); (L.Y.); (F.P.)
- Hubei Province Key Laboratory of Molecular Imaging, Jiefang Avenue #1277, Wuhan 430022, China
| | - Feng Pan
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue #1277, Wuhan 430022, China; (H.C.); (Y.F.); (J.G.); (L.Y.); (F.P.)
- Hubei Province Key Laboratory of Molecular Imaging, Jiefang Avenue #1277, Wuhan 430022, China
| | - Hongying Wu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue #1277, Wuhan 430022, China; (H.C.); (Y.F.); (J.G.); (L.Y.); (F.P.)
- Hubei Province Key Laboratory of Molecular Imaging, Jiefang Avenue #1277, Wuhan 430022, China
| | - Tianhe Ye
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue #1277, Wuhan 430022, China; (H.C.); (Y.F.); (J.G.); (L.Y.); (F.P.)
- Hubei Province Key Laboratory of Molecular Imaging, Jiefang Avenue #1277, Wuhan 430022, China
| |
Collapse
|
2
|
Grassi G, Laino ME, Kalra M, Cherchi MV, Nicola R, Mannelli L, Balestrieri A, Suri JS, Sala E, Saba L. Application of multi-spectral CT imaging in Crohn's disease: a systematic review. Acta Radiol 2023; 64:2347-2356. [PMID: 37138467 DOI: 10.1177/02841851231170849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
BACKGROUND No quantitative computed tomography (CT) biomarker is actually sufficiently accurate to assess Crohn's disease (CD) lesion activity, with adequate precision to guide clinical decisions. PURPOSE To assess the available literature on the use of iodine concentration (IC), from multi-spectral CT acquisition, as a quantitative parameter able to distinguish healthy from affected bowel and assess CD bowel activity and heterogeneity of activity along the involved segments. MATERIAL AND METHODS A literature search was conducted to identify original research studies published up to February 2022. The inclusion criteria were original research papers (>10 human participants), English language publications, focus on dual-energy CT (DECT) of CD with iodine quantification (IQ) as an outcome measure. The exclusion criteria were animal-only studies, languages other than English, review articles, case reports, correspondence, and study populations <10 patients. RESULTS Nine studies were included in this review; all of which showed a strong correlation between IC measurements and CD activity markers, such as CD activity index (CDAI), endoscopy findings and simple endoscopic score for Crohn's disease (SES-CD), and routine CT enterography (CTE) signs and histopathologic score. Statistically significant differences in IC were reported between affected bowel segments and healthy ones (higher P value was P < 0.001), normal segments and those with active inflammation (P < 0.0001) as well as between patients with active disease and those in remission (P < 0.001). CONCLUSION The mean normalized IC at DECTE could be a reliable tool in assisting radiologists in the diagnosis, classification and grading of CD activity.
Collapse
Affiliation(s)
- Giovanni Grassi
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), Cagliari, Italy
| | - Maria Elena Laino
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), Cagliari, Italy
- Artificial Intelligence Center, IRCSS Humanitas Research Hospital, Rozzano, Milano, Italy
| | - Mannudeep Kalra
- Department of Radiology, Massachusetts General Hospital and the Harvard Medical School, Boston, MA, USA
| | - Maria Valeria Cherchi
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), Cagliari, Italy
| | - Refky Nicola
- Department of Radiology, Roswell Park Cancer Institute, Jacobs School of Medicine and Biomedical Science, Buffalo, NY, USA
| | | | - Antonella Balestrieri
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), Cagliari, Italy
| | - Jasjit S Suri
- Diagnostic and Monitoring Division, AtheroPoint™, Roseville, CA, USA
- Knowledge Engineering Center, Global Biomedical Technologies, Inc., Roseville, CA, USA
- Department of Electrical and Computer Engineering, Idaho State University, Pocatello, ID, USA (Affl)
| | - Evis Sala
- Department of Radiology, University of Cambridge, Cambridge, UK
| | - Luca Saba
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), Cagliari, Italy
| |
Collapse
|
3
|
Liu S, Chen ZY. [Optimal Parameters for Virtual Mono-Energetic Imaging of Liver Solid Lesions]. Zhongguo Yi Xue Ke Xue Yuan Xue Bao 2023; 45:280-284. [PMID: 37157076 DOI: 10.3881/j.issn.1000-503x.15065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Objective To explore the optimal parameters for virtual mono-energetic imaging of liver solid lesions. Methods A retrospective analysis was performed on 60 patients undergoing contrast-enhanced spectral CT of the abdomen.The iodine concentration values of hepatic arterial phase images and the CT values of different mono-energetic images were measured.The correlation coefficient and coefficient of variation were calculated. Results The average correlation coefficients between iodine concentrations and CT values of hepatic solid lesion images at 40,45,50,55,60,65,and 70 keV were 0.996,0.995,0.993,0.989,0.978,0.970,and 0.961,respectively.The correlation coefficients at 40(P=0.007),45(P=0.022),50 keV (P=0.035)were higher than that at 55 keV,and the correlation coefficients at 40 keV(P=0.134) and 45 keV(P=0.368) had no significant differences from that at 50 keV.The coefficients of variation of the CT values at 40,45,and 50 keV were 0.146,0.154,and 0.163,respectively. Conclusion The energy of 40 keV is optimal for virtual mono-energetic imaging of liver solid lesions in the late arterial phase,which is helpful for the diagnosis of liver diseases.
Collapse
Affiliation(s)
- Shuang Liu
- Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China
| | - Zhi-Ye Chen
- Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China
| |
Collapse
|
4
|
Wang J, Zhang L, Cheng SM, Li B, Shen J. The evaluation of portal hypertension in cirrhotic patients with spectral computed tomography. Acta Radiol 2023; 64:918-925. [PMID: 35593049 DOI: 10.1177/02841851221101356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Iodine concentrations measured using dual-energy spectral CT (DESCT) have been recently proposed as providing good performance for examining tissues hemodynamics. PURPOSE To evaluate the diagnostic efficacy of DESCT-derived parameters in evaluating portal venous pressure in patients with liver cirrhosis. MATERIAL AND METHODS A total of 71 patients with liver cirrhosis who underwent percutaneous transhepatic portal vein puncture procedures were included in this study. All participants underwent DESCT and gastrointestinal endoscopy within one month before the operation. The direct portal venous pressure of each participant was measured preoperatively. RESULTS Stepwise multivariate linear regression analysis showed that the iodine concentrations in the portal vein and hepatic parenchyma during the portal venous phase and the platelet count were independently correlated with the direct portal venous pressure (P < 0.001, P < 0.001, and P = 0.030, respectively). Receiver operating characteristic analysis revealed that the normalized iodine concentration of the hepatic parenchyma had the best performance for identifying clinically significant portal hypertension (≥10 mmHg), esophageal varices, and high-risk esophageal varices (the area under the curve values were 0.951, 0.932, and 0.960, respectively). CONCLUSION The normalized iodine concentration of the hepatic parenchyma is a reliable parameter to non-invasively assess portal venous pressure in patients with liver cirrhosis.
Collapse
Affiliation(s)
- Jun Wang
- Department of Interventional Oncology, Renji Hospital, 71140Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Liang Zhang
- Department of Interventional Oncology, Renji Hospital, 71140Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Sai Ming Cheng
- Department of Radiology, Renji Hospital, 71140Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Bo Li
- Department of Radiology, Renji Hospital, 71140Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Jialin Shen
- Department of Interventional Oncology, Renji Hospital, 71140Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| |
Collapse
|
5
|
Muroga K, Minochi Y, Fukuzawa A. Improvement in arterial enhancement using diluted injection of contrast medium in CT angiography. Acta Radiol 2023; 64:489-495. [PMID: 35179050 DOI: 10.1177/02841851221077400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Arterial enhancement after contrast injection affects the quality of computed tomography angiography (CTA) images. PURPOSE To evaluate whether the dilution of contrast medium (CM) for CTA increases arterial enhancement after the adjustment of iodine concentration as per the patient's body weight (BW). MATERIAL AND METHODS We retrospectively studied 700 patients who underwent coronary CTA. The first 350 consecutive patients underwent standard CTA with a fixed iodine concentration, whereas the remaining 350 underwent CTA with a diluted CM injection. All patients were classified into three groups according to their BW (<55, 55-65, and 66-73 kg). The mean and proportion of contrast enhancements (CEs) in the ascending aorta of ≥350 Hounsfield units (HUs) (CE350) were compared between the standard CTA and diluted CM injection and among the BW groups. The associations between BW and CE were analyzed using linear regression. RESULTS Receiving diluted CM increased the mean CE in the <55-kg group (403.4 ± 55.4 HU vs. 382.8 ± 59.3 HU; P < 0.01) but not in the groups with heavier BW. The proportion of patients with CE350 increased with BW (<55 kg = 71%, 55-65 kg = 84%, and 66-73 kg = 91%) and increased after dilution (86%, 93%, and 96%, respectively). After CM dilution, the correlation between BW and CE among patients undergoing CTA decreased from 0.37 to 0.22 (P < 0.05). CONCLUSION CM dilution for CTA improves arterial enhancement.
Collapse
Affiliation(s)
- Koji Muroga
- Department of Diagnostic Radiology, 26869Nagano Red Cross Hospital, Nagano, Japan
| | - Yoshimi Minochi
- Department of Diagnostic Radiology, 26869Nagano Red Cross Hospital, Nagano, Japan
| | - Akira Fukuzawa
- Department of Diagnostic Radiology, 26869Nagano Red Cross Hospital, Nagano, Japan
| |
Collapse
|
6
|
Wang YL, Liu XL, Liao ZB, Lu XM, Chen LL, Lei Y, Zhang HW, Lin F. Dual-energy spectral detector computed tomography differential diagnosis of adrenal adenoma and pheochromocytoma: Changes in the energy level curve, a phenomenon caused by lipid components? Front Endocrinol (Lausanne) 2023; 13:998154. [PMID: 36686431 PMCID: PMC9854128 DOI: 10.3389/fendo.2022.998154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 12/07/2022] [Indexed: 01/07/2023] Open
Abstract
Background and objectives Pheochromocytoma and adrenal adenoma are common space-occupying lesions of the adrenal gland, and incorrect surgery may lead to adrenal crisis. We used a new method, dual-energy spectral detector computed tomography (SDCT), to differentiate between the two. Materials and methods We analysed the imaging images of patients with SDCT scans and pathologically confirmed adrenal adenomas (n=70) and pheochromocytomas (n=15). The 40, 70, and 100 KeV virtual monoenergetic images (VMIs) were reconstructed based on the SCDT arterial phase, and the correlation between the arterial/venous phase iodine concentration (AP-IC/VP-IC), the effective atomic number (Z-effect), the slope of the Hounsfield unit attenuation plot (VMI slope) and the pathological results was tested. The Shapiro-Wilk test was used to determine whether the above data conformed to a normal distribution. For parameters with P greater than 0.05, Student's t test was used, and the Mann-Whitney test was used for the remaining parameters. A ROC curve was drawn based on the results. Results Student's t test showed that the 40 KeV VMI and the VMI slope were both statistically significant (P<0.01). The Mann-Whitney U test showed that ID-A was statistically significant (P=0.004). ROC curve analysis showed that 40 keV VMI (AUC=0.818), AP-IC (AUC=0.736), difference (AUC=0.817) and VMI-Slope (0.817) could be used to differentiate adrenal adenoma from pheochromocytoma. Conclusion The effect of lipid components on SDCT parameters can be used to differentiate adrenal adenoma from pheochromocytoma.
Collapse
Affiliation(s)
- Yu-li Wang
- Department of Radiology, the First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People’s Hospital, Shenzhen, China
| | - Xiao-lei Liu
- Department of Radiology, the First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People’s Hospital, Shenzhen, China
| | - Ze-bing Liao
- Department of Radiology, the First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People’s Hospital, Shenzhen, China
| | - Xiao-mei Lu
- CT Clinical Science, Philips Healthcare, Shenyang, China
| | - Ling-lin Chen
- Department of Radiology, the First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People’s Hospital, Shenzhen, China
| | - Yi Lei
- Department of Radiology, the First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People’s Hospital, Shenzhen, China
| | - Han-wen Zhang
- Department of Radiology, the First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People’s Hospital, Shenzhen, China
| | - Fan Lin
- Department of Radiology, the First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People’s Hospital, Shenzhen, China
| |
Collapse
|
7
|
Wu W, Fang X, Li J, Zhang A, Zou Y, Zheng X. Application of dual-source computed tomography in the diagnosis of thyroid cancer and evaluation of biological behaviors. J Clin Ultrasound 2023; 51:195-202. [PMID: 36539919 DOI: 10.1002/jcu.23413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 11/23/2022] [Accepted: 12/03/2022] [Indexed: 06/17/2023]
Abstract
OBJECTIVE Thyroid cancer (TC) is an extremely prevailing malignant endocrine tumor. Therefore, effective diagnostic tools are necessary. This study explored the application value of dual-source computed tomography (DSCT) in TC diagnosis and biological behavior assessment. METHODS This study retrospectively selected 68 TC patients and another 74 benign patients with thyroid adenoma, nodular goiter, or adenomatous hyperplasia. All patients were confirmed by pathological examination and underwent DSCT examination. The iodine concentration (IC) obtained from plain computed tomography (CT) scanning and normalized iodine concentration (NIC) in the arterial phase and venous phase were recorded. The positive expression rates of estrogen receptor alpha (ERα), estrogen receptors beta (ERβ), and Ki67 in pathological tissues were determined by immunohistochemistry, and their correlation with IC in plain CT was assessed by Pearson correlation analysis, respectively. The diagnostic values of IC in plain CT and venous phase NIC in TC patients were evaluated using the receiver operating characteristic curve. RESULTS Malignant patients had lower IC in plain DSCT scanning, venous phase NIC, and ERβ, and higher ERα and Ki67 than benign patients. IC level in plain DSCT scanning was inversely-correlated with ERα and Ki-67 positive expression rates, but positively-related to ERβ to different degrees. For the diagnosis of TC patients, the AUC of IC level in plain DSCT was 0.771, with a cut-off value of 1.250 (97.06% sensitivity and 41.89% specificity), and the AUC of venous phase NIC was 0.738, with a cut-off value of 0.825 (100% sensitivity and 43.24% specificity). CONCLUSION The IC level obtained from DSCT scanning could assist in the differential diagnosis of malignant and benign thyroid nodules and evaluation of biological behaviors.
Collapse
Affiliation(s)
- Wenhui Wu
- Department of Radiology, Dongguan People's Hospital, Dongguan, China
| | - Xuewen Fang
- Department of Radiology, Dongguan People's Hospital, Dongguan, China
| | - Jianming Li
- Department of Radiology, Dongguan People's Hospital, Dongguan, China
| | - An Zhang
- Department of Radiology, Dongguan People's Hospital, Dongguan, China
| | - Yujian Zou
- Department of Radiology, Dongguan People's Hospital, Dongguan, China
| | - Xiaolin Zheng
- Department of Radiology, Kanghua Hospital, Dongguan, China
| |
Collapse
|
8
|
Kim J, Kim JY, Oh SW, Kim HG. Evaluating the Image Quality of Neck Structures Scanned on Chest CT with Low-Concentration-Iodine Contrast Media. Tomography 2022; 8:2854-63. [PMID: 36548531 DOI: 10.3390/tomography8060239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/21/2022] [Accepted: 11/24/2022] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND The purpose of this study was to investigate and compare the image quality of low-concentration-iodine (240 mgI/mL) contrast media (CM) and high-concentration-iodine (320 mgI/mL) CM according to the radiation dose. METHODS A total of 366 CT examinations were examined. Based on an assessment of quantitative and qualitative parameters by two radiologists, the quality was compared between Group A (low-concentration-iodine CM) and Group B (high-concentration-iodine CM) images of thyroid gland, sternocleidomastoid muscle (SCM), internal jugular vein (IJV), and common carotid artery (CCA). Another subgroup analysis compared Group a, (using ≤90 kVp in Group A), and Group b, (using ≥100 kVp in Group B) for finding the difference in image quality when the tube voltage is lowered. RESULTS Image quality did not differ between Groups A and B or between Groups a and b. The signal-to-noise ratio and contrast-to-noise ratio were significantly higher for Group B than Group A for the thyroid gland, IJV, and CCA. No statistical differences were found in the comparison of all structures between Groups a and b. CONCLUSION There was no significant difference in image quality based on CM concentration with variable radiation doses. Therefore, if an appropriate CT protocol is applied, clinically feasible neck CT images can be obtained even using low-concentration-iodine CM.
Collapse
|
9
|
Toshima F, Yoneda N, Terada K, Inoue D, Gabata T. DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study. Tomography 2022; 8:2698-2708. [PMID: 36412684 PMCID: PMC9680450 DOI: 10.3390/tomography8060225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/01/2022] [Accepted: 11/03/2022] [Indexed: 11/06/2022] Open
Abstract
Evaluating the similarity between two entities such as primary and suspected metastatic lesions using quantitative dual-energy computed tomography (DECT) numbers may be useful. However, the criteria for the similarity between two entities based on DECT numbers remain unclear. We therefore considered the possibility that a similarity in DECT numbers within the same organ could provide suitable standards. Thus, we assumed that the variation in DECT numbers within a single organ is sufficiently minimal to be considered clinically equivalent. Therefore, the purpose of this preliminary study is to investigate the differences in DECT numbers within upper abdominal organs. This retrospective study included 30 patients with data from hepatic protocol DECT scans. DECT numbers of the following parameters were collected: (a, b) 70 and 40 keV CT values, (c) slope, (d) effective Z, and (e, f) iodine and water concentration. The agreement of DECT numbers obtained from two regions of interest in the same organ (liver, spleen, and kidney) were assessed using Bland-Altman analysis. The diagnostic ability of each DECT parameter to distinguish between the same or different organs was also assessed using receiver operating characteristic analysis. The 95% limits of agreement within the same organ exhibited the narrowest value range on delayed phase (DP) CT [(c) -11.2-8.3%, (d) -2.0-1.5%, (e) -11.3-8.4%, and (f) -0.59-0.62%]. The diagnostic ability was notably high when using differences in DECT numbers on portal venous (PVP) and DP images (the area under the curve of DP: 0.987-0.999 in (c)-(f)). Using the variability in DECT numbers in the same organ as a criterion for defining similarity may be helpful in making a differential diagnosis by comparing the DECT numbers of two entities.
Collapse
|
10
|
Geng D, Chen X, Zhao XG, Xu XQ, Su GY, Zhou Y, Chen HB, Wu FY. Laryngeal and hypopharyngeal squamous cell carcinoma: association between quantitative parameters derived from dual-energy CT and histopathological prognostic factors. Acta Radiol 2022:2841851221095237. [PMID: 35502811 DOI: 10.1177/02841851221095237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Dual-energy computed tomography (DECT) can provide objective evaluation of laryngeal and hypopharyngeal squamous cell carcinoma (LHSCC). PURPOSE To investigate the relationship between quantitative parameters acquired from DECT and histopathological prognostic factors in LHSCC. MATERIAL AND METHODS A total of 65 patients with LHSCC who underwent arterial phase and venous phase DECT scans were retrospectively enrolled. Iodine concentration (IC) and normalized IC (NIC) of the tumor were calculated in both the arterial (ICA and NICA) and venous (ICV and NICV) phases, and compared among different pathological grades, T stages, and lymph node stages. Receiver operating characteristic (ROC) curves were generated to evaluate their diagnostic performance. RESULTS There were significantly differences on ICA and NICA among three pathological grades (ICA, P = 0.001; NICA, P = 0.002). For differentiating moderately and poorly differentiated from well-differentiated LHSCC using ICA and NICA, the areas under curve (AUCs) were 0.753 and 0.726, respectively. High T stage (T3/4) LHSCC showed significantly higher ICA (P = 0.012) and NICA (P = 0.005) than low T stage (T1/2) LHSCC. The AUCs of the ICA and NICA were 0.674 and 0.703, respectively, in discriminating high from low T stage LHSCC. Lymph node metastasis (LNM)-positive (N1/2/3) LHSCC showed significantly higher ICA (P = 0.008) and NICA (P = 0.003) than LNM-negative (N0) LHSCC. For discriminating the LNM-positive from the LNM-negative group using ICA and NICA, the AUCs were 0.697 and 0.744, respectively. CONCLUSION ICA and NICA might be helpful in assessing histopathological prognostic factors in patients with LHSCC.
Collapse
Affiliation(s)
- Di Geng
- Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Xi Chen
- Department of Otolaryngology, First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Xing-Guo Zhao
- Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Xiao-Quan Xu
- Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Guo-Yi Su
- Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Yan Zhou
- Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Hai-Bing Chen
- Department of Otolaryngology, First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Fei-Yun Wu
- Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| |
Collapse
|
11
|
Abstract
Background Using conventional computed tomography (CT), the accurate diagnosis of lymph
node (LN) metastasis of esophageal cancer is difficult. Purpose To examine dual-energy CT parameters to predict LN metastasis preoperatively
in patients with esophageal cancer. Material and Methods Twenty-six consecutive patients who underwent dual-energy CT before an
esophageal cancer surgery (19 patients with LN metastases) were analyzed.
The included LNs had a short-axis diameter of ≥4 mm and were confirmed to be
resected on postoperative CT. Their short-axis diameter, CT value, iodine
concentration (IC), and fat fraction were measured on early- and late-phase
contrast-enhanced dual-energy CT images and compared between pathologically
confirmed metastatic and non-metastatic LNs. Results In total, 51 LNs (34 metastatic and 17 non-metastatic) were included. In the
early phase, IC and fat fraction were significantly lower in the metastatic
than in the non-metastatic LNs (IC = 1.6 mg/mL vs. 2.2 mg/mL; fat
fraction = 20.3% vs. 32.5%; both P < 0.05). Furthermore,
in the late phase, IC and fat fraction were significantly lower in the
metastatic than in the non-metastatic LNs (IC = 2.0 mg/mL vs. 3.0 mg/mL; fat
fraction = 20.4% vs. 33.0%; both P < 0.05). Fat fraction
exhibited accuracies of 82.4% and 78.4% on early- and late-phase images,
respectively. Conversely, short-axis diameter and CT value on both early-
and late-phase images were not significantly different between the
metastatic and non-metastatic LNs (P > 0.05). Conclusion Using dual-energy CT images, IC and fat fraction are useful for diagnosing LN
metastasis in patients with esophageal cancer.
Collapse
Affiliation(s)
- Xuyang Sun
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| | - Tetsu Niwa
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| | - Soji Ozawa
- Department of Gastroenterological Surgery, Tokai University School of Medicine, Isehara, Japan
| | - Jun Endo
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| | - Jun Hashimoto
- Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan
| |
Collapse
|
12
|
Burdenski T, Bressem KK, Adams LC, Grauhan NF, Niehues SM. CT diagnostics of pulmonary embolism: Does iodine delivery rate still affect image quality in iterative reconstruction? Clin Hemorheol Microcirc 2021; 79:81-89. [PMID: 34487032 DOI: 10.3233/ch-219115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Computed tomographic (CT) imaging in suspected pulmonary artery embolism represents the standard procedure. Studies without iterative reconstruction proved beneficial using increased iodine delivery rate (IDR). This study compares image quality in pulmonary arteries on iteratively reconstructed CT images of patients with suspected pulmonary embolism using different IDR. MATERIAL AND METHODS 1065 patients were included in the study. Patients in group A (n = 493) received an iodine concentration of 40 g/100 ml (IDR 1.6 g/s) and patients in group B (n = 572) an iodine concentration of 35 g/100 ml (IDR 1.4 g/s) at a flow rate of 4 ml/s. A 80-detector spiral CT scanner with iterative reconstruction was used. We measured mean density values in truncus pulmonalis, both pulmonary arteries and segmental pulmonary arteries. Subjectively, the contrast of apical and basal pulmonary arteries was determined on a 4-point Likert scale. RESULTS Radiodensity was significantly higher in all measured pulmonary arteries using the increased IDR (p < 0.001). TP: 483.0 HU vs. 393.4 HU; APD: 452.1 HU vs. 372.1 HU; APS: 448.2 HU vs. 374.4 HU; ASP: 443.9 vs. 374.4 HU. Subjectively assessed contrast enhancement in apical (p = 0.077) and basal (p = 0.429) lung sections showed no significant differences. CONCLUSION Higher IDR improves objective image quality in all patients with significantly higher radiodensities by iterative reconstruction. Subjective contrast of apical and basal lung sections did not differ. The number of non-sufficient scans decreased with high IDR.
Collapse
Affiliation(s)
- Thomas Burdenski
- Institute for Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| | - Keno K Bressem
- Institute for Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany.,Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Lisa C Adams
- Institute for Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany.,Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Nils F Grauhan
- Institute for Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| | - Stefan M Niehues
- Institute for Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| |
Collapse
|
13
|
Machamba AAL, Priore SE, Macedo MDS, Franceschini SDCC. Ingestion of supplements and fortified food with iodine on the breast milk iodine concentration in deficiency areas: a systematic review. Afr Health Sci 2021; 21:1346-1354. [PMID: 35222600 PMCID: PMC8843278 DOI: 10.4314/ahs.v21i3.46] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Introduction The level of iodine in breast milk may be inadequate and compromise the health of this, both due to excess and lack, some population groups remain deficient because of the low consumption of iodate salt, because there is an increase in consumption of other sources of iodine, such as supplements and fortified foods. Objective To evaluate the effect of the consumption of fortified foods and nutritional supplements with iodine on maternal milk levels. Methodology Systematic review based on the Prism method, using the descriptors provided by DeCS. The reading, selection and analysis of the methodological quality of the articles was done by two researchers independently. Results From 346 abstracts, 6 were eligible. The median iodination range between the studies ranged from 75 to 600 µg in supplements and 150 and 225 µg in fortified foods with effect on increased iodine concentration of breastmilk (BMIC), achieving the adequacy of the median BMIC in 4 of the 6 studies. Conclusion Iodine ingestion through supplements or fortified foods results in improved iodine levels in breast milk.
Collapse
Affiliation(s)
- Almeida Abudo Leite Machamba
- Almeida A. L. Machamba: PhD Student in the Postgraduate Program in Nutrition Science, Department of Nutrition and Health, Federal University of Viçosa (UFV), Viçosa, Brazil
| | - Silvia Eloiza Priore
- Full PhD Professor in the the Postgraduate Program in Nutrition Science, Department of Nutrition and Health, Federal University of Viçosa (UFV), Viçosa, Brazil
| | - Mariana de Souza Macedo
- Post-Doctoral in the Postgraduate Program in Nutrition Science, Department of Nutrition and Health, Federal University of Viçosa (UFV), Viçosa, Brazil
| | - Sylvia do Carmo Castro Franceschini
- Full PhD Professor in the the Postgraduate Program in Nutrition Science, Department of Nutrition and Health and Pro-Rector of community affairs, Federal University of Viçosa (UFV), Viçosa, Brazil
| |
Collapse
|
14
|
Siro SS, Baumgartner J, Schoonen M, Ngounda J, Malan L, Symington EA, Smuts CM, Zandberg L. Characterization of Genetic Variants in the SLC5A5 Gene and Associations With Breast Milk Iodine Concentration in Lactating Women of African Descent: The NUPED Study. Front Nutr 2021; 8:692504. [PMID: 34368208 PMCID: PMC8342754 DOI: 10.3389/fnut.2021.692504] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 06/22/2021] [Indexed: 11/13/2022] Open
Abstract
Background: The sodium iodide symporter is responsible for the transfer of iodine into breast milk and is encoded for by the SLC5A5 gene. The role of genetic variants in the SLC5A5 gene locus in relation to the transfer of iodine from plasma into breast milk in healthy lactating individuals has, to our knowledge, not been explored. Objective: To identify and characterize possible genetic variants of the SLC5A5 gene in women of African descent living in urban South Africa, and to study associations with breast milk iodine concentrations (BMIC) in lactating women. Methods: This study is affiliated to the Nutrition during Pregnancy and Early Development (NuPED) cohort study (n = 250 enrolled pregnant women). In a randomly selected sub-sample of 32 women, the SLC5A5 gene was sequenced to identify known and novel variants. Of the identified variants, genotyping of selected variants was performed in all pregnant women who gave consent for genetic analyses (n = 246), to determine the frequency of the variants in the study sample. Urinary iodine concentration (UIC) in spot urine samples and BMIC were measured to determine iodine status. Associations of SLC5A5 genetic variants with BMIC were studied in lactating women (n = 55). Results: We identified 27 variants from sequencing of gene exomes and 10 variants were selected for further study. There was a significant difference in BMIC between the genotypes of the rs775249401 variant (P = 0.042), with the homozygous GG group having lower BMIC [86.8 (54.9-167.9) μg/L] compared to the (A) allele carriers rs775249401(AG+AA) [143.9 (122.4-169.3) μg/L] (P = 0.042). Of the rs775249401(GG), 49% had UIC <100 μg/L and 61% had BMIC <100 μg/L. On the other hand, 60% of the rs775249401(AG+AA) carriers had UIC <100 μg/L, and none had a BMIC <100 μg/L. Conclusion: Our results suggest that A-allele carriers of rs775249401(AG+AA) are likely to have higher iodine transfer into breast milk compared to the homozygous GG counterparts. Thus, genetic variations in the SLC5A5 gene may play an important role in the transfer of iodine from plasma into breast milk and may partially explain inter-individual variability in BMIC.
Collapse
Affiliation(s)
- Sicelosethu S. Siro
- Centre of Excellence for Nutrition, North-West University, Potchefstroom, South Africa
| | - Jeannine Baumgartner
- Centre of Excellence for Nutrition, North-West University, Potchefstroom, South Africa
- Human Nutrition Laboratory, Department of Health Sciences and Technology, Institute of Food, Nutrition and Health, ETH Zurich, Zurich, Switzerland
| | - Maryke Schoonen
- Centre of Excellence for Nutrition, North-West University, Potchefstroom, South Africa
| | - Jennifer Ngounda
- Department of Nutrition and Dietetics, University of the Free State, Bloemfontein, South Africa
| | - Linda Malan
- Centre of Excellence for Nutrition, North-West University, Potchefstroom, South Africa
| | - Elizabeth A. Symington
- Department of Life and Consumer Sciences, University of South Africa, Johannesburg, South Africa
| | - Cornelius M. Smuts
- Centre of Excellence for Nutrition, North-West University, Potchefstroom, South Africa
| | - Lizelle Zandberg
- Centre of Excellence for Nutrition, North-West University, Potchefstroom, South Africa
| |
Collapse
|
15
|
Meng QL, Xu H, Zong LX, Liu MQ, Chen ZY. [Reproducibility Analysis of Iodine Concentrations of Abdominal Parenchymal Organs Based on Spectral CT]. Zhongguo Yi Xue Ke Xue Yuan Xue Bao 2021; 43:57-62. [PMID: 33663664 DOI: 10.3881/j.issn.1000-503x.12548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Objective To investigate the intra-and inter-observer reproducibility of iodine concentrations of abdominal parenchymal organs based on spectral CT.Methods The water-free iodine images of the venous phase were retrospectively obtained from 50 patients with abdominal dynamic spectral CT scans.The iodine concentrations were measured in the left,right and caudate lobes of liver,spleen,pancreas and bilateral kidneys.Intraclass correlation coefficient(ICC)and Bland-Altman plot were employed to analyze the intra-and inter-observer reproducibility.Results The intra-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.938(0.894,0.965),0.932(0.884,0.961),0.939(0.895,0.965),0.947(0.909,0.970),0.912(0.851,0.949),0.946(0.906,0.969)and 0.907(0.842,0.946),which indicated good intra-observer reproducibility.The inter-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.947(0.909,0.970),0.927(0.875,0.958),0.943(0.902,0.968),0.956(0.924,0.975),0.934(0.887,0.962),0.927(0.875,0.958)and 0.892(0.818,0.937),which indicated good inter-observer reproducibility.Bland-Altman plots presented that more than 95% points of the intra-observer differences located within 95% CI of limits of agreement for the caudate lobe of liver,spleen,pancreas and bilateral kidneys,which was same as inter-observer differences of the caudate lobe of liver,spleen and right kidney.Conclusion The iodine concentration measurement based on the spectral CT presented good intra-and inter-observer reproducibility for the caudate lobe of liver and spleen.
Collapse
Affiliation(s)
- Qing Lin Meng
- Department of Radiology,Hainan Hospital of PLA General Hospital,Sanya,Hainan 572013,China
| | - Huan Xu
- Department of Radiology,Hainan Hospital of PLA General Hospital,Sanya,Hainan 572013,China
| | - Lin Xiong Zong
- Department of Radiology,Hainan Hospital of PLA General Hospital,Sanya,Hainan 572013,China
| | - Meng Qi Liu
- Department of Radiology,Hainan Hospital of PLA General Hospital,Sanya,Hainan 572013,China
- Department of Radiology,First Medical Center of PLA General Hospital,Beijing 100853,China
| | - Zhi Ye Chen
- Department of Radiology,Hainan Hospital of PLA General Hospital,Sanya,Hainan 572013,China
| |
Collapse
|
16
|
Meng QL, Zong LX, Liu MQ, Wang PH, Chen ZY. [Optimal Mono-energy in Mono-energetic Spectral Computed Tomography of Enhanced Renal Cortex in Cortical Phase Based on Iodine Concentration]. Zhongguo Yi Xue Ke Xue Yuan Xue Bao 2020; 42:776-780. [PMID: 33423725 DOI: 10.3881/j.issn.1000-503x.11915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Objective To identify the optimal mono-energetic enhanced spectral CT for renal cortex in cortical phase based on the iodine concentration. Methods Fifty patients with normal renal function received the abdominal enhanced spectral CT examination.The iodine concentration and CT values of the multiple mono-energetic spectral images were measured on renal cortex in cortical phase,and the correlation between the iodine concentration and the CT values and the coefficient of variation(CV)were analyzed. Results The correlation analysis demonstrated that the correlation coefficient was 0.994,0.994,0.993,0.987,0.976,0.960,and 0.938 between mono-energetic spectral CT images(40-100 keV with interval 10 keV,respectively)and iodine concentration(all P <0.001).The correlation coefficients of 40 keV,50 keV(P=0.007)and 60 keV(P=0.030)were significantly higher compared with that of 70 keV,and the correlation coefficients were not significantly among 40 keV,50 keV and 60 keV(P =0.590).The CV of renal cortex in cortical phase was 0.21,0.20,and 0.19 for 40 keV,50 keV,and 60 keV,respectively. Conclusion 60 keV is the optimal mono-energy for the enhanced spectral CT of the renal cortex in cortical phase.
Collapse
Affiliation(s)
- Qing Lin Meng
- Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China
| | - Lin Xiong Zong
- Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China
| | - Meng Qi Liu
- Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China
| | - Ping Huai Wang
- Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China
| | - Zhi Ye Chen
- Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China
| |
Collapse
|
17
|
Ayala-Domínguez L, Pérez-Cárdenas E, Avilés-Salas A, Medina LA, Lizano M, Brandan ME. Quantitative Imaging Parameters of Contrast-Enhanced Micro-Computed Tomography Correlate with Angiogenesis and Necrosis in a Subcutaneous C6 Glioma Model. Cancers (Basel) 2020; 12:E3417. [PMID: 33217988 PMCID: PMC7698719 DOI: 10.3390/cancers12113417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 11/16/2020] [Accepted: 11/16/2020] [Indexed: 12/04/2022] Open
Abstract
The aim of this work was to systematically obtain quantitative imaging parameters with static and dynamic contrast-enhanced (CE) X-ray imaging techniques and to evaluate their correlation with histological biomarkers of angiogenesis in a subcutaneous C6 glioma model. Enhancement (E), iodine concentration (CI), and relative blood volume (rBV) were quantified from single- and dual-energy (SE and DE, respectively) micro-computed tomography (micro-CT) images, while rBV and volume transfer constant (Ktrans) were quantified from dynamic contrast-enhanced (DCE) planar images. CI and rBV allowed a better discernment of tumor regions from muscle than E in SE and DE images, while no significant differences were found for rBV and Ktrans in DCE images. An agreement was found in rBV for muscle quantified with the different imaging protocols, and in CI and E quantified with SE and DE protocols. Significant strong correlations (Pearson r > 0.7, p < 0.05) were found between a set of imaging parameters in SE images and histological biomarkers: E and CI in tumor periphery were associated with microvessel density (MVD) and necrosis, E and CI in the complete tumor with MVD, and rBV in the tumor periphery with MVD. In conclusion, quantitative imaging parameters obtained in SE micro-CT images could be used to characterize angiogenesis and necrosis in the subcutaneous C6 glioma model.
Collapse
Affiliation(s)
- Lízbeth Ayala-Domínguez
- Programa de Doctorado en Ciencias Biomédicas, Instituto de Investigaciones Biomédicas, Universidad Nacional Autónoma de México, Ciudad de México 04510, Mexico;
- Unidad de Investigación Biomédica en Cáncer INCan/UNAM, Instituto Nacional de Cancerología, Ciudad de México 14080, Mexico;
| | - Enrique Pérez-Cárdenas
- Subdirección de Investigación Básica, Instituto Nacional de Cancerología, Ciudad de México 14080, Mexico;
| | - Alejandro Avilés-Salas
- Departamento de Patología, Instituto Nacional de Cancerología, Ciudad de México 14080, Mexico;
| | - Luis Alberto Medina
- Unidad de Investigación Biomédica en Cáncer INCan/UNAM, Instituto Nacional de Cancerología, Ciudad de México 14080, Mexico;
- Departamento de Física Experimental, Instituto de Física, Universidad Nacional Autónoma de México, Ciudad de México 04510, Mexico
| | - Marcela Lizano
- Unidad de Investigación Biomédica en Cáncer INCan/UNAM, Instituto Nacional de Cancerología, Ciudad de México 14080, Mexico;
- Departamento de Medicina Genómica y Toxicología Ambiental, Instituto de Investigaciones Biomédicas, Universidad Nacional Autónoma de México, Ciudad de México 04510, Mexico
| | - María-Ester Brandan
- Departamento de Física Experimental, Instituto de Física, Universidad Nacional Autónoma de México, Ciudad de México 04510, Mexico
| |
Collapse
|
18
|
Xu JJ, Taudorf M, Ulriksen PS, Achiam MP, Resch TA, Nielsen MB, Lönn LB, Hansen KL. Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review. Diagnostics (Basel) 2020; 10:diagnostics10100814. [PMID: 33066281 PMCID: PMC7602017 DOI: 10.3390/diagnostics10100814] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 10/04/2020] [Accepted: 10/07/2020] [Indexed: 12/15/2022] Open
Abstract
Dual-energy computed tomography (DECT) can estimate tissue vascularity and perfusion via iodine quantification. The aim of this systematic review was to outline current and emerging clinical applications of iodine quantification within the gastrointestinal tract using DECT. The search was conducted with three databases: EMBASE, Pubmed and The Cochrane Library. This identified 449 studies after duplicate removal. From a total of 570 selected studies, 30 studies were enrolled for the systematic review. The studies were categorized into four main topics: gastric tumors (12 studies), colorectal tumors (8 studies), Crohn’s disease (4 studies) and miscellaneous applications (6 studies). Findings included a significant difference in iodine concentration (IC) measurements in perigastric fat between T1–3 vs. T4 stage gastric cancer, poorly and well differentiated gastric and colorectal cancer, responders vs. non-responders following chemo- or chemoradiotherapy treatment among cancer patients, and a positive correlation between IC and Crohn’s disease activity. In conclusion, iodine quantification with DECT may be used preoperatively in cancer imaging as well as for monitoring treatment response. Future studies are warranted to evaluate the capabilities and limitations of DECT in splanchnic flow.
Collapse
Affiliation(s)
- Jack Junchi Xu
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Correspondence:
| | - Mikkel Taudorf
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Peter Sommer Ulriksen
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Michael Patrick Achiam
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Department of Vascular Surgery, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark
| | - Timothy Andrew Resch
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
- Department of Clinical Medicine, University of Copenhagen, 2100 Copenhagen, Denmark
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Lars Birger Lönn
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| | - Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.B.N.); (L.B.L.); (K.L.H.)
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (M.T.); (P.S.U.); (M.P.A.); (T.A.R.)
| |
Collapse
|
19
|
Su L, Xie CL, Sun Q, Gao JB. [Clinical value of quantitative parameters by spectral CT in parotid gland tumor]. Hua Xi Kou Qiang Yi Xue Za Zhi 2019; 37:631-635. [PMID: 31875442 DOI: 10.7518/hxkq.2019.06.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVE This study aimed to investigate the value of normalized iodine concentration (NIC), spectral attenuation curve slope (SACS), area under curve (AUC), and iodine concentration difference (ICD) generated from spectral CT in the assessment of parotid gland tumors. METHODS Ninety-two patients with pathologically confirmed parotid gland tumors underwent arterial phase- and venous phase-enhanced CT in spectral CT. The patients were divided into the pleomor-phic adenoma group (group A), Warthin tumor group (group B), basal cell tumor group (group C), and malignant tumor group (group D). The SACS, AUC, NIC, ICD were measured and analyzed. Statistical analyses were performed by one-way ANOVA, and statistical significance was set at P<0.05. RESULTS SACS(AP), AUC(AP), and NIC(AP) in group A were lower than those in other groups; SACS(VP) and AUC(VP) in group C were higher than those in other groups; NIC(AP) and NIC(VP) in group D were higher than those in other groups; and ICD in group B was a positive number. The difference in SACS(AP) and AUC(AP) in groups B and C, SACS(VP) and AUC(VP) in groups C and D, and ICD in groups A and C were not statistically significant. By contrast, the diffe-rence between the other groups was statistically significant (P<0.05). The difference in NIC(AP) between groups A and B and groups C and D and the difference in NIC(VP) between groups A and C, groups A and D, and groups B and C were statistically significant (P=0.005, 0.025, 0.002, 0.038, and 0.049, respectively). CONCLUSIONS Multi-quantitative parameters from spectral CT might be helpful in differentiating various types of parotid gland tumors.
Collapse
Affiliation(s)
- Lei Su
- Dept. of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Chen-Lu Xie
- Dept. of Stomatology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Qiang Sun
- Dept. of Stomatology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Jian-Bo Gao
- Dept. of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| |
Collapse
|
20
|
Abstract
Background/aim This study aimed to investigate the relationship between the iodine concentration (IC) of perigastric fat tissue as assessed by dual-energy computed tomography (DECT) and serosal invasion of gastric cancer. Materials and methods A total of 41 patients underwent preoperative staging evaluation for gastric cancer using DECT between July 2015 and March 2018. Patients were divided into 2 groups based on pathology results: serosal invasion (stage T4a) and intact serosa (stages T1–T3). Cutoff values, the diagnostic efficacy of IC in the perigastric fat tissue, and the perigastric fat tissue/tumor (P/T) ratio were determined. Results Among the 41 patients, 22 had stage T4a gastric cancer and 19 patients had gastric cancer with a stage lower than T4a. The mean IC of perigastric fat tissue and the P/T ratio were significantly higher in patients with serosal invasion than in those with intact serosa (P < 0.001). During the arterial phase, the area under the curve (AUC) was 0.915 and 0.854 for the IC of perigastric fat tissue and the P/T ratio, respectively. During the venous phase, the AUC was 0.890 and 0.876 for the IC of perigastric fat tissue and the P/T ratio, respectively. Conclusion The IC in the perigastric fat tissue seems to be a reliable indicator for serosal invasion of gastric cancer.
Collapse
Affiliation(s)
- Ali Küpeli
- Department of Radiology, Faculty of Medicine, Erzincan Binali Yıldırım University, Erzincan, Turkey
| | - Eser Bulut
- Department of Radiology, Trabzon Kanuni Training and Research Hospital, Trabzon, Turkey
| | - Ayşegül Cansu
- Department of Radiology, Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey
| | - Ali Güner
- Department of General Surgery, Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey
| | - Mehmet Soytürk
- Department of Radiology, Faculty of Medicine, Erzincan Binali Yıldırım University, Erzincan, Turkey
| | - Gürkan Danışan
- Department of Radiology, Muş State Hospital, Muş, Turkey
| |
Collapse
|
21
|
Sato K, Morohashi H, Tsushima F, Sakamoto Y, Miura T, Fujita H, Umemura K, Suzuki T, Tsuruta S, Kura R, Ono S, Aoki M, Hakamada K. Dual energy CT is useful for the prediction of mesenteric and lateral pelvic lymph node metastasis in rectal cancer. Mol Clin Oncol 2019; 10:625-630. [PMID: 31031979 DOI: 10.3892/mco.2019.1834] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Accepted: 03/20/2019] [Indexed: 12/12/2022] Open
Abstract
The aim of the present retrospective study was to investigate the predictability of dual-energy computed tomography (DECT) for pararectal lymph node (PRLN) metastasis and lateral pelvic lymph node (LPLN) metastasis in rectal cancer (RC). The present study involved 44 patients with RC who were examined by DECT and then underwent surgery between May 2015 and September 2017. LPLN dissection was performed in 24 patients. The normalized iodine concentration (nIC), the ratio of iodine concentration in the lymph node (LN) to that in the common iliac artery on DECT, of the largest PRLN and LPLN was calculated, and the association between LN metastasis and nIC was analyzed. The median nIC value for PRLNs was significantly lower in PRLN metastasis-positive cases compared with PRLN metastasis-negative cases in the arterial phase [0.18 vs. 0.25; P=0.01; cut-off, 0.24; area under the curve (AUC), 0.733] and portal phase (0.47 vs. 0.61; P=0.03; cut-off, 0.59; AUC, 0.701). A significant difference was not identified between the median maximum short axis diameter of PRLNs in PRLN metastasis-positive and metastasis-negative cases (7.6 vs. 6.4 mm; P=0.33). The nIC for LPLNs was not significantly different between LPLN metastasis-positive and metastasis-negative cases in the arterial phase (0.15 vs. 0.21; P=0.19); but was significantly lower in LPLN metastasis-positive cases compared with LPLN metastasis-negative cases in the portal phase (0.29 vs. 0.56; P=0.04; cut-off, 0.29; AUC, 0.877). The maximum short axis diameter of LPLNs was significantly larger in metastasis-positive cases compared with LPLN metastasis-negative cases (9.1 vs. 4.8 mm; P=0.03; cut-off, 7.0 mm; AUC, 0.912). In conclusion, the nIC was identified to be significantly lower in metastasis-positive cases, which may be useful for the prediction of PRLN and LPLN metastases. A combination of size-based diagnosis and DECT may increase the accuracy of preoperative diagnosis.
Collapse
Affiliation(s)
- Kentaro Sato
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Hajime Morohashi
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Fumiyasu Tsushima
- Department of Radiation and Oncology, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Yoshiyuki Sakamoto
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Takuya Miura
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Hiromasa Fujita
- Department of Radiation and Oncology, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Kotaro Umemura
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Takahiro Suzuki
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Satoru Tsuruta
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Ryoto Kura
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Shuichi Ono
- Department of Radiation and Oncology, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Masahiko Aoki
- Department of Radiation and Oncology, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| | - Kenichi Hakamada
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori 036-8562, Japan
| |
Collapse
|
22
|
Hwang YS, Cheung YC, Lin YY, Hsu HL, Tsai HY. Susceptibility of iodine concentration map of dual-energy contrast-enhanced digital mammography for quantitative and tumor enhancement assessment. Acta Radiol 2018; 59:893-901. [PMID: 29117707 DOI: 10.1177/0284185117740760] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Background Dual-energy (DE) contrast-enhanced digital mammography (DE-CEDM) provides additional information on tumor angiogenesis. Purpose To investigate the susceptibility of reconstructing color-coded iodine concentration maps on the basis of quantitative calibrations of the iodine concentration and contrast-to-noise ratio (CNR) in DE-CEDM applications. Material and Methods A custom-made phantom filled with iodine concentrations in the range of 0.1-10 mg/cm2 was used in calibrations. All DE images were acquired using the GE Senographe Essential system. From DE subtraction images, the image contrast and CNR were obtained, and the quantitative relationship between these two metrics and the iodine concentration at each phantom thickness was investigated. The quantitative CNR calibration curves were applied to reconstruct color-coded iodine maps on a pixel-by-pixel basis. Results Both the mean contrast and mean CNR increased linearly with the iodine concentration. The iodine concentration estimated from the iodine map reconstructed from quantitative CNR calibrations was highly consistent with the desired iodine concentration (R2 = 0.989), and smaller relative errors (in the range of 3.0-19.5%) were observed with iodine concentrations not less than 1 mg/cm2. Conclusion An iodine concentration map could be reconstructed based on the linear relationship between the CNR and iodine concentration. From the color-coded iodine concentration map, the contrast medium enhancement phenomenon could be further estimated quantitatively, and tumor enhancement patterns could be easily observed.
Collapse
Affiliation(s)
- Yi-Shuan Hwang
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Yun-Chung Cheung
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Yu-Ying Lin
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Hsiao-Lan Hsu
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Taoyuan, Taiwan
| | - Hui-Yu Tsai
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu, Taiwan
| |
Collapse
|
23
|
Chen X, Ren K, Liang P, Li J, Chen K, Gao J. Association between spectral computed tomography images and clinicopathological features in advanced gastric adenocarcinoma. Oncol Lett 2017; 14:6664-6670. [PMID: 29163693 PMCID: PMC5686525 DOI: 10.3892/ol.2017.7064] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 07/07/2017] [Indexed: 02/06/2023] Open
Abstract
To investigate the role of spectral computed tomography (CT)-generated iodine concentration (IC) in the evaluation of clinicopathological features of advanced gastric adenocarcinoma (AGC), 42 patients who underwent abdominal enhanced CT with spectral imaging mode were selected for the present study. The IC of the primary lesion in the arterial phase (ICAP) and portal venous phase (ICVP) was measured and the IC of the aorta was used for a normalized iodine concentration (nIC). Micro-vessel density (MVD) and lymphatic vessel density (LVD) were detected using immunohistochemical assays against cluster of differentiation 34 and D2-40, respectively. Other clinicopathological characteristics were also documented. The IC parameters were revealed to be significantly increased in the high-MVD group, particularly for the nICVP (P=0.002). Additionally, the nICAP revealed a significant difference (P=0.041) between the high- and low-LVD group. The nICAP and nICVP were increased in the poorly differentiated group compared with the moderately differentiated group (P=0.040 and P=0.011, respectively). The ICs and MVD demonstrated a statistically significant positive linear correlation. nICVP was able to be used to discriminate between the moderately and poorly differentiated carcinomas, with an area under the receiver operating characteristic curve of 0.759. However, IC demonstrated no correlation with serosal involvement, lymph node metastasis, LVD, and nodular or metastatic tumors. The results of the present study suggest that the nICVP value may serve as a non-invasive marker for the angiogenesis of, and the differentiations between, patients with AGC.
Collapse
Affiliation(s)
- Xiaohua Chen
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
| | - Ke Ren
- Department of Gastroenterological Surgery, Luohe Central Hospital, Luohe, Henan 462000, P.R. China
| | - Pan Liang
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
| | - Jiayin Li
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
| | - Kuisheng Chen
- Department of Pathology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
| | - Jianbo Gao
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
| |
Collapse
|
24
|
Papadakis AE, Damilakis J. Fast kVp-switching dual energy contrast-enhanced thorax and cardiac CT: A phantom study on the accuracy of iodine concentration and effective atomic number measurement. Med Phys 2017; 44:4724-4735. [PMID: 28658505 DOI: 10.1002/mp.12437] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Revised: 06/18/2017] [Accepted: 06/18/2017] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To assess the effect of vessel diameter and exposure parameters on the estimation accuracy of concentration and effective atomic number (Zeff ) of iodine (I) in contrast-enhanced thorax and cardiac dual-energy CT using a modern fast kVp-switching CT scanner. METHODS A standard semi-anthropomorphic cardiac CT phantom devised to simulate the human chest at three different body habitus i.e., medium-sized, large-sized, and obese, was scanned using a fast kVp-switching Revolution-GSI GE CT scanner. Five cylindrical, 10 mm diameter, vials were filled with solutions prepared by diluting I contrast at five concentrations (2.5, 5, 10, 15, and 20 mg I/ml). To simulate small vessels, pipette tips with a diameter ranging from 5 mm to 0.5 mm were employed. The vials and pipette tips were accommodated within the semi-anthropomorphic phantom. CT acquisitions were performed in the fast kVp-switching dual-energy mode at six different CTDIw values. Acquisitions were also performed at 80, 100, 120, and 140 kVp. Images were acquired at 64 × 0.625 mm beam collimation and reconstructed at 2.5 mm using all available reconstruction filter kernels. Virtual monochromatic spectral (VMS) images, iodine concentration (IMeas ), and Zeff maps were reconstructed. Hounsfield unit as a function of energy (HUkeV ) in VMS and single-kVp (HUkVp ), IMeas and Zeff were measured at each CTDIw . The effect of vessel diameter on IMeas and Zeff was investigated. Measured HUkeV and Zeff were compared to theoretically estimated values and IMeas were compared to nominal (INom ) values. RESULTS In 10 mm diameter vessels, HUkeV values were accurate to 18% for the medium-sized, 22% for the large-sized and 39% for the obese phantoms. IMeas was underestimated by up to 10% for the medium-sized, 26% for the large-sized and 33% for the obese phantom. IMeas error decreased with increasing CTDIw from ±0.799 mg/ml at 8.61 mGy to ±0.082 mg/ml at 32.01 mGy. The percentage difference between measured and theoretically estimated Zeff ranged from -3.9% to -14.5%. In pipette tip vessels, IMeas was found to depend on the kernel employed. At the standard kernel, IMeas , for INom = 20 mg/ml, was reduced with vessel diameter from 19.25 ± 0.39 mg/ml, at 10 mm, to 2.52 ± 0.31 mg/ml, at 1 mm. Linear regression between IMeas and INom resulted in IMeas /INom factors of 0.925 for 5 mm, 0.815 for 4 mm, 0.651 for 3 mm, 0.377 for 2 mm, and 0.129 for 1 mm vessel diameter. Measured Zeff values were underestimated when vessel diameter was decreased from 5 mm to 1 mm by 27% for the 20 mg I/ml and 21% for the 2.5 mg I/ml. CONCLUSIONS HUkeV , IMeas , and Zeff depend on several parameters such as body size, vessel size, exposure parameters, and reconstruction kernel. The limiting spatial resolution of the CT system results in considerable underestimation of HUkVp , IMeas , and Zeff in vessels smaller than 5 mm diameter. The underestimation of I uptake may be experimentally corrected, if the diameter of the investigated vessel is measured and the correction factors produced in this study are employed.
Collapse
Affiliation(s)
- Antonios E Papadakis
- Department of Medical Physics, University Hospital of Heraklion, P.O. Box 1352, Heraklion, Crete, 71110, Greece
| | - John Damilakis
- Department of Medical Physics, University of Crete, Medical School, P.O. Box 1352, Heraklion, Crete, 71110, Greece
| |
Collapse
|
25
|
Gao SY, Zhang XY, Wei W, Li XT, Li YL, Xu M, Sun YS, Zhang XP. Identification of benign and malignant thyroid nodules by in vivo iodine concentration measurement using single-source dual energy CT: A retrospective diagnostic accuracy study. Medicine (Baltimore) 2016; 95:e4816. [PMID: 27684811 PMCID: PMC5265904 DOI: 10.1097/md.0000000000004816] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
This study proposed to determine whether in vivo iodine concentration measurement by single-source dual energy (SSDE) CT can improve differentiation between benign and malignant thyroid nodules. In total, 53 patients presenting with thyroid nodules underwent SSDE CT scanning. Iodine concentrations were measured for each nodule and normal thyroid tissue using the GSI-viewer image analysis software. A total of 26 thyroid nodules were malignant in 26 patients and confirmed by surgery; 33 nodules from 27 patients were benign, with 10 confirmed by surgery and others after follow-up. Iodine concentrations with plain CT were significantly lower in malignant than benign nodules (0.47 ± 0.20 vs 1.17 ± 0.38 mg/mL, P = 0.00). Receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 0.93; with a cutoff of 0.67, iodine concentration showed 92.3% sensitivity and 88.5% specificity in diagnosing malignancy. Iodine concentration obtained by enhanced and plain CT were significantly higher in malignant than benign nodules (9.05 ± 3.35 vs 3.46 ± 2.24 mg/mL, P = 0.00). ROC curve analysis showed an AUC of 0.93; with a cutoff value of 3.37, iodine concentration displayed 78% sensitivity, 95% specificity in diagnosing malignancy. Combining unenhanced with enhanced iodine concentrations, the diagnostic equation was: Y = -8.641 × unenhanced iodine concentration + 0.663 × iodine concentration. ROC curve showed an AUC of 0.98 (95% CI, 0.94, 1.00). With Y ≥ -2 considered malignancy, diagnostic sensitivity and specificity were 96%, 96.3%, respectively. This study concluded that SSDE CT can detect the differences in iodine uptake and blood supply between benign and malignant thyroid lesions.
Collapse
Affiliation(s)
- Shun-Yu Gao
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology
| | - Xiao-Yan Zhang
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology
| | - Wei Wei
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Head and Neck Surgery, Peking University Cancer Hospital & Institute
| | - Xiao-Ting Li
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology
| | - Yan-Ling Li
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology
| | - Min Xu
- KLMI, Institute of Automation, Chinese Academy of Sciences, Beijing, China
| | - Ying-Shi Sun
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology
- Correspondence: Ying-Shi Sun, Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology, Peking University Cancer Hospital & Institute, Beijing, China (e-mail: )
| | - Xiao-Peng Zhang
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology
| |
Collapse
|
26
|
Henjum S, Kjellevold M, Ulak M, Chandyo RK, Shrestha PS, Frøyland L, Strydom EE, Dhansay MA, Strand TA. Iodine Concentration in Breastmilk and Urine among Lactating Women of Bhaktapur, Nepal. Nutrients 2016; 8:E255. [PMID: 27136582 DOI: 10.3390/nu8050255] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 04/15/2016] [Accepted: 04/21/2016] [Indexed: 11/24/2022] Open
Abstract
Adequate iodine concentration in breastmilk (BMIC) is essential for optimal neonatal thyroid hormone synthesis and neurological development in breastfed infants. For many decades, iodine deficiency has been a public health problem in Nepal. However, recently, excessive iodine intakes among Nepali infants have been reported. This study aimed to measure BMIC and urinary iodine concentration (UIC) among lactating women in a peri-urban area of Nepal. Iodine concentration was measured in spot urine (n = 485) and breastmilk samples (n = 291) of 500 randomly selected lactating women. The median (p25, p75) BMIC and median UIC were 250 (130, 370) µg/L and 230 (135–377) µg/L, respectively. Around 82% had BMIC > 100 µg/L, 61% had BMIC > 200 µg/L and 81% had UIC > 100 µg/L, 37% had >300 µg/L and 20% had >500 µg/L. In multiple linear regression models, time since birth (β 3.0, 95% CI (0.2, 5.0)) and UIC (β 1.0, 95% CI (0.1, 2.0)) were associated with BMIC, explaining 26% of the variance. A large proportion of the women had adequate BMIC and UIC; however, a subset had high iodine concentrations. These findings emphasize the importance of carefully monitoring iodine intake to minimize the risk of iodine excess and subsequently preventing transient iodine-induced hypothyroidism in breastfed infants.
Collapse
|
27
|
Abdul Razak HR, Shaffiq Said Rahmat SM, Md Saad WM. Effects of different tube potentials and iodine concentrations on image enhancement, contrast-to-noise ratio and noise in micro-CT images: a phantom study. Quant Imaging Med Surg 2013; 3:256-61. [PMID: 24273743 DOI: 10.3978/j.issn.2223-4292.2013.10.04] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2013] [Accepted: 10/29/2013] [Indexed: 01/04/2023]
Abstract
The study aimed to investigate the effects of different tube potentials and concentrations of iodinated contrast media (CM) on the image enhancement, contrast-to-noise ratio (CNR) and noise in micro-computed tomography (µCT) images. A phantom containing of five polyethylene tube was filled with 2 mL of deionized water and iodinated CM (Omnipaque 300 mgI/mL) at four different concentrations: 5, 10, 15, and 20 mol/L, respectively. The phantom was scanned with a µCT machine (SkyScan 1176) using various tube potentials: 40, 50, 60, 70, 80, and 90 kVp, a fixed tube current; 100 µA, and filtration of 0.2 mm aluminum (Al). The percentage difference of image enhancement, CNR and noise of all images, acquired at different kVps and concentrations, were calculated. The image enhancement, CNR and noise curves with respect to tube potential and concentration were plotted and analysed. The highest image enhancement was found at the lowest tube potential of 40 kVp. At this kVp setting, the percentage difference of image enhancement [Hounsfield Unit (HU) of 20 mol/L iodine concentration over HU of deionized water] was 43%. By increasing the tube potential, it resulted with the reduction of HU, where only 17.5% different were noticed for 90 kVp. Across all iodine concentrations (5-20 M), CNR peaked at 80 kVp and then these values showed a slight decreasing pattern, which might be due insufficient tube current compensation. The percentage difference of image noise obtained at 40 and 90 kVp was 72.4%. Lower tube potential setting results in higher image enhancement (HU) in conjunction with increasing concentration of iodinated CM. Overall, the tube potential increment will substantially improve CNR and reduce image noise.
Collapse
|