1
|
Engelke K, Chaudry O, Gast L, Eldib MAB, Wang L, Laredo JD, Schett G, Nagel AM. Magnetic resonance imaging techniques for the quantitative analysis of skeletal muscle: State of the art. J Orthop Translat 2023; 42:57-72. [PMID: 37654433 PMCID: PMC10465967 DOI: 10.1016/j.jot.2023.07.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 07/04/2023] [Accepted: 07/19/2023] [Indexed: 09/02/2023] Open
Abstract
Background Magnetic resonance imaging (MRI) is the dominant 3D imaging modality to quantify muscle properties in skeletal muscle disorders, in inherited and acquired muscle diseases, and in sarcopenia, in cachexia and frailty. Methods This review covers T1 weighted and Dixon sequences, introduces T2 mapping, diffusion tensor imaging (DTI) and non-proton MRI. Technical concepts, strengths, limitations and translational aspects of these techniques are discussed in detail. Examples of clinical applications are outlined. For comparison 31P-and 13C-MR Spectroscopy are also addressed. Results MRI technology provides a rich toolset to assess muscle deterioration. In addition to classical measures such as muscle atrophy using T1 weighted imaging and fat infiltration using Dixon sequences, parameters characterizing inflammation from T2 maps, tissue sodium using non-proton MRI techniques or concentration or fiber architecture using diffusion tensor imaging may be useful for an even earlier diagnosis of the impairment of muscle quality. Conclusion Quantitative MRI provides new options for muscle research and clinical applications. Current limitations that also impair its more widespread use in clinical trials are lack of standardization, ambiguity of image segmentation and analysis approaches, a multitude of outcome parameters without a clear strategy which ones to use and the lack of normal data.
Collapse
Affiliation(s)
- Klaus Engelke
- Department of Medicine III, Friedrich-Alexander University of Erlangen-Nürnberg, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
- Institute of Medical Physics (IMP), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Henkestr. 91, 91052, Erlangen, Germany
- Clario Inc, Germany
| | - Oliver Chaudry
- Department of Medicine III, Friedrich-Alexander University of Erlangen-Nürnberg, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
| | - Lena Gast
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | | | - Ling Wang
- Department of Radiology, Beijing Jishuitan Hospital, Beijing, China
| | - Jean-Denis Laredo
- Service d’Imagerie Médicale, Institut Mutualiste Montsouris & B3OA, UMR CNRS 7052, Inserm U1271 Université de Paris-Cité, Paris, France
| | - Georg Schett
- Department of Medicine III, Friedrich-Alexander University of Erlangen-Nürnberg, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
| | - Armin M. Nagel
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| |
Collapse
|
2
|
Xiang QS. Two-point water-fat imaging with partially-opposed-phase (POP) acquisition: An asymmetric Dixon method. Magn Reson Med 2006; 56:572-84. [PMID: 16894578 DOI: 10.1002/mrm.20984] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A novel two-point water-fat imaging method is introduced. In addition to the in-phase acquisition, water and fat magnetization vectors are sampled at partially-opposed-phase (POP) rather than exactly antiparallel as in the original Dixon method. This asymmetric sampling encodes more valuable phase information for identifying water and fat. From the magnitudes of the two complex images, a big and a small chemical component are first robustly obtained pixel by pixel and then used to form two possible error phasor candidates. The true error phasor is extracted from the two error phasor candidates through a simple procedure of regional iterative phasor extraction (RIPE). Finally, least-squares solutions of water and fat are obtained after the extracted error phasor is smoothed and removed from the complex images. For noise behavior, the effective number of signal averages NSA* is typically in the range of 1.87-1.96, very close to the maximum possible value of 2. Compared to earlier approaches, the proposed method is more efficient in data acquisition and straightforward in processing, and the final results are more robust. At both 1.5T and 0.3T, well separated and identified in vivo water and fat images covering a broad range of anatomical regions have been obtained, supporting the clinical utility of the method.
Collapse
Affiliation(s)
- Qing-San Xiang
- Department of Radiology, University of British Columbia, Vancouver, Canada.
| |
Collapse
|
3
|
Rybicki FJ, Chung T, Reid J, Jaramillo D, Mulkern RV, Ma J. Fast three-point dixon MR imaging using low-resolution images for phase correction: a comparison with chemical shift selective fat suppression for pediatric musculoskeletal imaging. AJR Am J Roentgenol 2001; 177:1019-23. [PMID: 11641161 DOI: 10.2214/ajr.177.5.1771019] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study is to describe and to implement a new fast three-point Dixon MR imaging sequence with online image reconstruction, and to compare this sequence with conventional chemical shift selective (CHESS) suppression of fat in pediatric musculoskeletal imaging. SUBJECTS AND METHODS A three-point Dixon technique using a fast spin-echo sequence with a new phase-correction algorithm providing online image reconstruction was implemented on a 1.5-T scanner. Twelve pediatric patients and young adults were imaged with both the new three-point Dixon and conventional CHESS sequences. Three radiologists un-aware of imaging parameters and clinical information independently scored the homogeneity of fat suppression and conspicuity of abnormality using a four-point system. An additional comparison between the two techniques was made using a phantom. RESULTS The three-point Dixon method showed superior fat suppression and lesion conspicuity (p < 0.001), particularly in the hands and feet, where CHESS is prone to inconsistent fat suppression. The phantom study showed no significant difference in the ratio of suppressed fat signal to background noise and more homogeneous fat suppression using the three-point Dixon method. CONCLUSION Compared with CHESS, the new fast three-point Dixon sequence with online image reconstruction provides superior fat suppression and lesion conspicuity and can be routinely used in pediatric musculoskeletal imaging.
Collapse
Affiliation(s)
- F J Rybicki
- Department of Radiology, Children's Hospital and Harvard Medical School, 330 Longwood Ave., Boston, MA 02115, USA
| | | | | | | | | | | |
Collapse
|