1
|
Oncu A, Sisko E, Demirel A, Celikten B. The evaluation of the accuracy of a wireless electronic apex locator in primary molar teeth. BMC Oral Health 2024; 24:1580. [PMID: 39741258 DOI: 10.1186/s12903-024-05387-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Accepted: 12/24/2024] [Indexed: 01/02/2025] Open
Abstract
BACKGROUND The working length determination is necessary before root canal shaping, chemical cleaning, disinfection, and obturation in pulpectomy of primary dentition. This study aimed to evaluate the accuracy of Wirele-X and compare it with DentaPort ZX and Woodpex III in primary molar teeth. METHODS The in vitro study was performed by using 30 extracted primary mandibular molar teeth. In distal roots, the actual working length was determined by taking forward a #10 K-type canal file under a dental operating microscope with 10x magnification. Each tooth and lip clip were embedded in alginate before determining the working lengths using electronic apex locators. The average of three electronic working lengths was calculated for each sample, and the actual working length was subtracted from the electronic working length. RESULTS There were no significant differences in the accuracy rate of DentaPort ZX, Wirele-X, and Woodpex III in the determination of the working length set at ± 0.5 mm and ± 1 mm, respectively (P > 0.05). CONCLUSIONS This study reported that DentaPort ZX, Wirele-X, and Woodpex III can be safely used in the pulpectomy of primary molars. Wirele-X can provide an advantage in working length determination in children because of its wireless feature.
Collapse
Affiliation(s)
- Aysenur Oncu
- Faculty of Dentistry, Department of Endodontics, Lokman Hekim University, Çankaya/Ankara, Turkey.
| | - Ecem Sisko
- Faculty of Dentistry, Department of Endodontics, Ankara University, Ankara, Turkey
| | - Akif Demirel
- Faculty of Dentistry, Department of Pediatric Dentistry, Ankara University, Ankara, Turkey
| | - Berkan Celikten
- Faculty of Dentistry, Department of Endodontics, Ankara University, Ankara, Turkey
| |
Collapse
|
2
|
Monteiro Czornobay LF, de Oliveira Rocha A, Leite CC, Menezes Dos Anjos L, Ribeiro JS, Pacheco de Castro Henriques BA, Cardoso M, Machado R, da Silveira Teixeira C, da Fonseca Roberti Garcia L. A Global Overview on Electronic Apex Locator Use From 1968 to 2023: A Bibliometric Analysis. J Endod 2024; 50:925-933. [PMID: 38614449 DOI: 10.1016/j.joen.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 04/01/2024] [Accepted: 04/02/2024] [Indexed: 04/15/2024]
Abstract
INTRODUCTION This bibliometric review analyzed the research trends and main characteristics of articles related to Electronic Apex Locators (EALs). METHODS The search was conducted in November 2023 on the Web of Science Core Collection. Narrative and systematic reviews, observational and intervention studies, laboratory, and clinical studies were included. Two researchers selected the articles and extracted the number of citations, year of publication, journal, study design, theme, country, continent, institutions, author, and keywords. Collaborative networks were generated using the VOSviewer software. The relationship between data were determined by Spearman's correlation. RESULTS The search resulted in 374 articles, of which 294 were included. Most cited article had 175 citations. The most prevalent journal was the Journal of Endodontics (n = 84). The predominant study design was the laboratory-based (n = 223). The predominant theme was the EALs accuracy (n = 175). Piasecki L was the author with the highest number of articles (n = 11). Only 8.16% of the studies were conducted in deciduous teeth. The country with the most studies was Brazil (n = 46). Asia (n = 107) was the continent with the highest number of publications. There was a weak positive correlation between the number of citations and impact factor (rho = .294), and a strong negative correlation between citations and year of publication (rho = -.710). CONCLUSIONS The majority of articles were laboratory-based studies conducted on permanent teeth, focusing on the accuracy of EALs. Future studies should prioritize research on deciduous teeth, systematic reviews, and, notably, clinical trials.
Collapse
Affiliation(s)
| | - Aurélio de Oliveira Rocha
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Christiane Cabral Leite
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Lucas Menezes Dos Anjos
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Juliana Silva Ribeiro
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | | | - Mariane Cardoso
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Ricardo Machado
- Department of Restorative Sciences, College of Dentistry, University of Oklahoma, Oklahoma City, Oklahoma
| | | | | |
Collapse
|
3
|
Cardoso IV, Silveira MPC, Vitali FC, Piasecki L, da Fonseca Roberti Garcia L, Bortoluzzi EA, Teixeira CS. Evaluation of changes in root canal length and accuracy of the electronic apex locator during different stages of endodontic treatment and retreatment. Odontology 2024; 112:537-545. [PMID: 37644294 DOI: 10.1007/s10266-023-00846-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 08/07/2023] [Indexed: 08/31/2023]
Abstract
This study evaluated changes in the root canal length (RCL) and the accuracy of the electronic apex locator (EAL) during the different stages of endodontic treatment and retreatment. Fifty-six mesial root canals of mandibular molars were selected. The actual root canal length (AL) of the canals was obtained by inserting a size 15 hand file up to the apical foramen, under magnification. The electronic lengths were obtained at the "APEX" mark of Root ZX II, using an alginate model. Both measurements were performed at three different stages of the initial root canal treatment-unflared, flared, and concluded-and at two stages of retreatment, after achieving patency and repreparation. Data were statistically analyzed and the significance level established was 5%. All stages produced a significant reduction in the AL (p < 0.05). The greatest variation was observed between the unflared-flared stages (0.2 mm) and between concluded-patency stages (0.09 mm), with no difference between them (p > 0.05). The accuracy of Root ZX II was negatively affected after achieving patency, presenting statistically significant difference compared to the other stages (p < 0.05). A significant reduction in the RCL was observed along the different stages of endodontic treatment and retreatment. The EAL was accurate to measure the root canals in most stages, except after achieving patency for endodontic retreatment. Determining and monitoring the RCL is an essential step towards a favorable prognosis, since it reduced along the different stages evaluated. Root ZX II was not accurate for endodontic retreatment.
Collapse
Affiliation(s)
- Ihan Vitor Cardoso
- Department of Dentistry-Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Campus João David Ferreira Lima, Trindade, Florianópolis, SC, Brazil
| | - Matheus Pompeo Caldas Silveira
- Department of Dentistry-Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Campus João David Ferreira Lima, Trindade, Florianópolis, SC, Brazil
| | - Filipe Colombo Vitali
- Department of Dentistry-Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Campus João David Ferreira Lima, Trindade, Florianópolis, SC, Brazil
| | - Lucila Piasecki
- Department of Periodontics and Endodontics, University at Buffalo, New York, NY, USA
| | - Lucas da Fonseca Roberti Garcia
- Department of Dentistry-Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Campus João David Ferreira Lima, Trindade, Florianópolis, SC, Brazil
| | - Eduardo Antunes Bortoluzzi
- Department of Diagnosis and Oral Health, School of Dentistry, University of Louisville, Louisville, KY, USA
| | - Cleonice Silveira Teixeira
- Department of Dentistry-Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Campus João David Ferreira Lima, Trindade, Florianópolis, SC, Brazil.
| |
Collapse
|
4
|
De-Deus G, Cozer V, Souza EM, Silva EJNL, Belladonna FG, Simões-Carvalho M, Versiani MA. Clinical accuracy and precision of 3 multi-frequency electronic apex locators assessed through micro-CT imaging. J Endod 2023; 49:487-495. [PMID: 36848949 DOI: 10.1016/j.joen.2023.02.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 02/19/2023] [Indexed: 02/27/2023]
Abstract
INTRODUCTION This study aimed to compare the in vivo accuracy and precision of 3 electronic apex locators (EALs) in determining the position of the major foramen using micro-computed tomographic (micro-CT) technology. METHODS After access preparation of 23 necrotic or vital teeth from 5 patients, canals were negotiated and hand files were used to determine the position of the foramen with 3 EALs: Propex Pixi, Woodpex III and Root ZX II. After fixing the silicon stop to the file, teeth were extracted and scanned in a micro-CT device with and without the instrument inserted into the canal. Datasets were co-registered, and the accuracy and precision of the EALs were determined at a tolerance level of ± 0.5 mm by measuring the distance from the tip of the instruments to a tangential line crossing the margins of the foramen. Statistical comparisons were performed using Friedman with post hoc Related Samples Sign and Spearman tests (α = 5%). RESULTS A significant difference was detected comparing the accuracy of Root ZX II (100%), Woodpex III (86.96%) and Propex Pixi (52.17%) (P < .05). There was a lack of significance in the relationship between the pulp status and the accuracy of tested EALs (P > .05). Propex Pixi was significantly less precise than Root ZX II (P < .05), while no difference was found between Woodpex III to either Root ZX II or Propex Pixi (P > .05). CONCLUSIONS EALs presented similar precision, but Woodpex III and Root ZX II showed better accuracy to determine the position of the apical foramen than Propex Pixi.
Collapse
Affiliation(s)
- Gustavo De-Deus
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Viviany Cozer
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Erick Miranda Souza
- Department of Dentistry II, Federal University of Maranhão, São Luís, Maranhão
| | - Emmanuel João Nogueira Leal Silva
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil; Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | | | - Marco Simões-Carvalho
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Marco Aurélio Versiani
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil; Dental Specialty Center, Brazilian Military Police, Minas Gerais, Brazil
| |
Collapse
|
5
|
De-Deus G, Cozer V, Souza EM, Silva EJNL, Wigler R, Belladonna FG, Simões-Carvalho M, Versiani MA. Micro-CT study of the in vivo accuracy of a wireless electronic apex locator. J Endod 2022; 48:1152-1160. [PMID: 35780927 DOI: 10.1016/j.joen.2022.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 06/02/2022] [Accepted: 06/06/2022] [Indexed: 11/16/2022]
Abstract
INTRODUCTION This study aimed to compare the in vivo accuracy of Wirele-X and RootZX II electronic apex locators (EALs) in determining the position of the major foramen using micro-CT as analytical tool. METHODS Eleven vital teeth from 5 patients planned for extraction were used. After conventional access cavity preparation, root canals were flared and negotiated up to the apical third with sizes 08 and 10 K-files followed by irrigation with 2.5% NaOCl. K-type files were used to determine the working length of the selected canals using Root ZX II and Wirele-X apex locators until their numeric displays read '0.0'. After fixing the silicon stop to the file, teeth were extracted and imaged in a micro-CT device using a double-scan protocol. Image stacks, with and without the file in the root canal, were then co-registered and the measurement error calculated as the absolute difference between the tip of the file and the major foramen. Positive and negative values were recorded when the file tip was detected beyond or short the major foramen, respectively. Accuracy was determined on stable measurements within ± 0.5 mm when the file tip did not extend beyond the major foramen. The Chi-square test was applied to compare the ability of the EALs to detect the position of the major foramen, while T test for dependent variables was used to verify differences in the two measurements obtained in each tooth. Significance level was set at 5%. RESULTS Within a tolerance level of ± 0.5 mm, no significant differences were observed between the tested EALs regarding the absolute distance values (p=0.82) or in their ability to detect the position of the major foramen (Χ2=0.2588; p=0.6109). The accuracy of the Root ZX II and the Wirele-X apex locators within ± 0.5 mm were 81.8% and 90.9%, respectively. CONCLUSIONS Root ZX II and Wirele-X performed similarly regarding the in vivo detection of the major foramen. Using strict criteria, the accuracy of the Root ZX II and the Wirele-X apex locators were 81.8% and 90.9%, respectively.
Collapse
Affiliation(s)
- Gustavo De-Deus
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.
| | - Viviany Cozer
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Erick Miranda Souza
- Department of Dentistry II, Federal University of Maranhão, São Luís, Maranhão
| | - Emmanuel João Nogueira Leal Silva
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil; Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - Ronald Wigler
- Department of Endodontology, Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel
| | | | - Marco Simões-Carvalho
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Marco Aurélio Versiani
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil; Dental Specialty Center, Brazilian Military Police, Minas Gerais, Brazil
| |
Collapse
|