1
|
Liu Y, Mu X, Wang Y, Xu Z, Song Y. The Role of 4D Flow MRI-derived Wall Shear Stress in Aortic Disease: A Comprehensive Review. Rev Cardiovasc Med 2025; 26:26735. [PMID: 40160589 PMCID: PMC11951489 DOI: 10.31083/rcm26735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2024] [Revised: 12/16/2024] [Accepted: 12/20/2024] [Indexed: 04/02/2025] Open
Abstract
Aortic diseases, such as aortic dissection and aortic rupture, often lead to catastrophic complications, significantly increasing morbidity and mortality. Population-based screening for early detection in asymptomatic individuals is not feasible due to high costs and practical challenges. However, recent advancements in four dimensions (4D) Flow magnetic resonance imaging (MRI) offer a comprehensive tool for evaluating hemodynamic changes within the aortic lumen. This technology allows for the quantification and visualization of flow patterns and the calculation of advanced hemodynamic parameters, such as wall shear stress (WSS). WSS is crucial in the development, risk stratification, and surgical outcomes of aortic diseases and their complications, enabling noninvasive and quantitative screening of high-risk populations. This review explores the current status and limitations of 4D flow MRI-derived WSS imaging for aortic disease.
Collapse
Affiliation(s)
- Ying Liu
- Department of Radiology, Central Hospital of Dalian University of Technology, 116033 Dalian, Liaoning, China
- Department of Graduate School, Dalian Medical University, 116044 Dalian, Liaoning, China
| | - Xiaolin Mu
- Department of Radiology, Central Hospital of Dalian University of Technology, 116033 Dalian, Liaoning, China
| | - Yixin Wang
- Department of Radiology, Central Hospital of Dalian University of Technology, 116033 Dalian, Liaoning, China
| | - Zhe Xu
- Department of Radiology, Central Hospital of Dalian University of Technology, 116033 Dalian, Liaoning, China
| | - Yang Song
- Department of Radiology, Central Hospital of Dalian University of Technology, 116033 Dalian, Liaoning, China
| |
Collapse
|
2
|
Liu MY, Wang M, Liu J, Sun AQ, He CS, Cong X, Kong W, Li W. Hemodynamic disturbance and mTORC1 activation: Unveiling the biomechanical pathogenesis of thoracic aortic aneurysms in Marfan syndrome. J Pharm Anal 2025; 15:101120. [PMID: 39989903 PMCID: PMC11847113 DOI: 10.1016/j.jpha.2024.101120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 09/19/2024] [Accepted: 10/10/2024] [Indexed: 02/25/2025] Open
Abstract
Thoracic aortic aneurysm (TAA) significantly endangers the lives of individuals with Marfan syndrome (MFS), yet the intricacies of their biomechanical origins remain elusive. Our investigation delves into the pivotal role of hemodynamic disturbance in the pathogenesis of TAA, with a particular emphasis on the mechanistic contributions of the mammalian target of rapamycin (mTOR) signaling cascade. We uncovered that activation of the mTOR complex 1 (mTORC1) within smooth muscle cells, instigated by the oscillatory wall shear stress (OSS) that stems from disturbed flow (DF), is a catalyst for TAA progression. This revelation was corroborated through both an MFS mouse model (Fbn1 +/C1039G) and clinical MFS specimens. Crucially, our research demonstrates a direct linkage between the activation of the mTORC1 pathway and the intensity in OSS. Therapeutic administration of rapamycin suppresses mTORC1 activity, leading to the attenuation of aberrant SMC behavior, reduced inflammatory infiltration, and restoration of extracellular matrix integrity-collectively decelerating TAA advancement in our mouse model. These insights posit the mTORC1 axis as a strategic target for intervention, offering a novel approach to manage TAAs in MFS and potentially pave insights for current treatment paradigms.
Collapse
Affiliation(s)
- Ming-Yuan Liu
- Department of Vascular Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing Center of Vascular Surgery, Beijing, 100050, China
- Department of Vascular Surgery, Peking University People's Hospital, Beijing, 100044, China
| | - Meili Wang
- Department of Physiology and Pathophysiology, School of Basic Medical Sciences, Capital Medical University, Beijing, 100069, China
| | - Junjun Liu
- Department of Vascular Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - An-Qiang Sun
- School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Chang-Shun He
- Department of Vascular Surgery, Peking University People's Hospital, Beijing, 100044, China
| | - Xin Cong
- Department of Physiology and Pathophysiology, School of Basic Medical Sciences, Peking University, Beijing, 100191, China
- The Key Laboratory of Molecular Cardiovascular Science, Ministry of Education, Beijing, 100191, China
| | - Wei Kong
- Department of Physiology and Pathophysiology, School of Basic Medical Sciences, Peking University, Beijing, 100191, China
- The Key Laboratory of Molecular Cardiovascular Science, Ministry of Education, Beijing, 100191, China
| | - Wei Li
- Department of Vascular Surgery, Peking University People's Hospital, Beijing, 100044, China
- The Key Laboratory of Molecular Cardiovascular Science, Ministry of Education, Beijing, 100191, China
| |
Collapse
|
3
|
Grafton-Clarke C, Ramachenderam L, Matthews G, Broncano J, Garg P. How can Four-Dimensional Magnetic Resonance Imaging Improve the Diagnosis of Heart Disease? Br J Hosp Med (Lond) 2024; 85:1-18. [PMID: 39618231 DOI: 10.12968/hmed.2024.0382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2024]
Abstract
This review describes the evolution and enhanced diagnostic capabilities introduced by four-dimensional (4D) flow cardiac magnetic resonance (CMR) in cardiovascular imaging. It charts the historical advancements from echocardiography through to two-dimensional phase-contrast magnetic resonance imaging (2D-PC MRI), culminating in the adoption of 4D flow MRI. This technique affords exhaustive, time-resolved, three-dimensional visualisations of intracardiac and vascular blood flow, refining the accuracy of cardiovascular assessments over traditional methods, especially in complex anatomical settings. The review elaborates on the capacity of 4D flow MRI to offer unparalleled insights into flow dynamics, vessel wall interactions, and cardiac function, thereby enhancing disease detection, risk stratification, and therapeutic evaluations. It accentuates the impact of 4D flow MRI on modern cardiological practices, highlighting its pivotal role in advancing diagnostics and patient management in the context of diverse cardiovascular pathologies.
Collapse
Affiliation(s)
- Ciaran Grafton-Clarke
- Norwich Medical School, University of East Anglia, Norwich, UK
- Norfolk and Norwich University Hospitals, Norwich, UK
| | | | - Gareth Matthews
- Norwich Medical School, University of East Anglia, Norwich, UK
- Norfolk and Norwich University Hospitals, Norwich, UK
| | | | - Pankaj Garg
- Norwich Medical School, University of East Anglia, Norwich, UK
- Norfolk and Norwich University Hospitals, Norwich, UK
| |
Collapse
|
4
|
Karam R, Elged BA, Elmetwally O, El-Etreby S, Elmansy M, Elhawary M. Porto-mesenteric four-dimensional flow MRI: a novel non-invasive technique for assessment of gastro-oesophageal varices. Insights Imaging 2024; 15:231. [PMID: 39331303 PMCID: PMC11436693 DOI: 10.1186/s13244-024-01805-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 09/01/2024] [Indexed: 09/28/2024] Open
Abstract
OBJECTIVES To assess the role of 4D flow MRI in the assessment of gastro-oesophageal varices and in the prediction of high-risk varices in patients with chronic liver disease. METHODS Thirty-eight patients diagnosed with either oesophageal or gastric varices were included in this single-centre prospective study. 4D flow MRI was used to calculate peak flow, average flow and peak velocity at the portal vein confluence (PV1) and hilum (PV2), splenic vein hilum (SV1) and confluence (SV2), and superior mesenteric vein (SMV). PV and SV fractional flow changes were also measured. RESULTS ROC analysis revealed that both PV2 average flow and PV fractional average flow change had 100% sensitivity to predict high-risk patients with the PV fractional peak flow change having the widest area under the curve (AUC) and the highest specificity (92.3%). SV1 average flow, SV2 average flow, SV2 peak flow, and SV2 peak velocity increased significantly in patients with oesophageal compared to gastric varices included (p = 0.022, < 0.001, < 0.001 and 0.001, respectively). CONCLUSION Based on certain porto-mesenteric blood flow, velocity, and fractional flow change parameters, 4D flow MRI showed excellent performance in identifying high-risk patients and giving an idea about the grade and location of varices. CRITICAL RELEVANCE STATEMENT Variceal bleeding is a major consequence of unidentified risky upper GI varices. Thus, by identifying and locating high-risk varices early, either oesophageal or gastric, using a non-invasive method like MRI, adverse events might be avoided. KEY POINTS 4D flow MRI can be used as a potential alternative for endoscopy to predict patients with high-risk varices. Based on portal vein fractional flow change, splenic flow and velocity, 4D MRI can predict and locate high-risk varices. Earlier identification of high-risk varices can allow for interventions to prevent adverse events.
Collapse
Affiliation(s)
- Rasha Karam
- Department of Radiology, Mansoura University, Mansoura, Egypt.
| | - Basma A Elged
- Department of Radiology, Mansoura University, Mansoura, Egypt
| | - Omar Elmetwally
- Department of Internal Medicine, Hepatology and Gastroenterology Unit, Mansoura University, Mansoura, Egypt
| | - Shahira El-Etreby
- Department of Internal Medicine, Hepatology and Gastroenterology Unit, Mansoura University, Mansoura, Egypt
| | - Mostafa Elmansy
- Department of Radiology, Mansoura University, Mansoura, Egypt
| | | |
Collapse
|
5
|
Aalbregt E, Indrakusuma R, Jalalzadeh H, Planken RN, van Schuppen J, Meijboom L, Balm R, Nederveen AJ, Yeung KK, van Ooij P. Four-Dimensional Flow MRI-Derived Hemodynamics in Abdominal Aortic Aneurysms: Reproducibility and Associations With Diameter, Intraluminal Thrombus Volume, and Vorticity. J Magn Reson Imaging 2024; 60:878-888. [PMID: 38006298 DOI: 10.1002/jmri.29138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 11/02/2023] [Accepted: 11/02/2023] [Indexed: 11/27/2023] Open
Abstract
BACKGROUND Maximum diameter measurements are used to assess the rupture risk of abdominal aortic aneurysms (AAAs); however, these are not precise enough to predict all ruptures. Four-dimensional (4D) flow MRI-derived parameters provide additional information by visualizing hemodynamics in AAAs but merit further investigation before they are clinically applicable. PURPOSE To assess the reproducibility of 4D flow MRI-derived hemodynamics, to investigate possible correlations with lumen and maximum diameter, and to explore potential relationships with vorticity and aneurysm growth. STUDY TYPE Prospective single-arm study. POPULATION A total of 22 (71.5 ± 6.1 years, 20 male) asymptomatic AAA patients with a maximum diameter of at least 30 mm. FIELD STRENGTH/SEQUENCE A 3.0 T/Free-breathing 4D flow MRI phase-contrast acquisition with retrospective ECG-gating. ASSESSMENT Patients underwent two consecutive 4D flow MRI scans 1-week apart. Aortic volumes were segmented from time-averaged phase contrast magnetic resonance angiographies. Reproducibility was assessed by voxelwise analysis after registration. Mean flow velocity, mean wall shear stress (WSS), mean lumen diameter, and qualitative vorticity scores were assessed. In addition, Dixon MRI and retrospective surveillance data were used to study maximum diameter (including thrombus), intraluminal thrombus volume (ILT), and growth rate. STATISTICAL TESTS For reproducibility assessment, Bland-Altman analyses, Pearson correlation, Spearman's correlation, and orthogonal regression were conducted. Potential correlations between hemodynamics and vorticity scores were assessed using linear regression. P < 0.05 was considered statistically significant. RESULTS Test-retest median Pearson correlation coefficients for flow velocity and WSS were 0.85 (IQR = 0.08) m/sec and 0.82 (IQR = 0.10) Pa, respectively. Mean WSS significantly correlated with mean flow velocity (R = 0.75) and inversely correlated with mean lumen diameter (R = -0.73). No significant associations were found between 4D flow MRI-derived hemodynamic parameters and maximum diameter (flow velocity: P = 0.98, WSS: P = 0.22). DATA CONCLUSION A 4D flow MRI is robust for assessing the hemodynamics within AAAs. No correlations were found between hemodynamic parameters and maximum diameter, ILT volume and growth rate. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Eva Aalbregt
- Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Reza Indrakusuma
- Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Hamid Jalalzadeh
- Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - R Nils Planken
- Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
| | - Joost van Schuppen
- Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
| | - Lilian Meijboom
- Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
| | - Ron Balm
- Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Aart J Nederveen
- Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Kak Khee Yeung
- Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Pim van Ooij
- Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| |
Collapse
|
6
|
Paloschi V, Pauli J, Winski G, Wu Z, Li Z, Botti L, Meucci S, Conti P, Rogowitz F, Glukha N, Hummel N, Busch A, Chernogubova E, Jin H, Sachs N, Eckstein H, Dueck A, Boon RA, Bausch AR, Maegdefessel L. Utilization of an Artery-on-a-Chip to Unravel Novel Regulators and Therapeutic Targets in Vascular Diseases. Adv Healthc Mater 2024; 13:e2302907. [PMID: 37797407 PMCID: PMC11468405 DOI: 10.1002/adhm.202302907] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/18/2023] [Indexed: 10/07/2023]
Abstract
In this study, organ-on-chip technology is used to develop an in vitro model of medium-to-large size arteries, the artery-on-a-chip (AoC), with the objective to recapitulate the structure of the arterial wall and the relevant hemodynamic forces affecting luminal cells. AoCs exposed either to in vivo-like shear stress values or kept in static conditions are assessed to generate a panel of novel genes modulated by shear stress. Considering the crucial role played by shear stress alterations in carotid arteries affected by atherosclerosis (CAD) and abdominal aortic aneurysms (AAA) disease development/progression, a patient cohort of hemodynamically relevant specimens is utilized, consisting of diseased and non-diseased (internal control) vessel regions from the same patient. Genes activated by shear stress follow the same expression pattern in non-diseased segments of human vessels. Single cell RNA sequencing (scRNA-seq) enables to discriminate the unique cell subpopulations between non-diseased and diseased vessel portions, revealing an enrichment of flow activated genes in structural cells originating from non-diseased specimens. Furthermore, the AoC served as a platform for drug-testing. It reproduced the effects of a therapeutic agent (lenvatinib) previously used in preclinical AAA studies, therefore extending the understanding of its therapeutic effect through a multicellular structure.
Collapse
Affiliation(s)
- Valentina Paloschi
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
- German Center for Cardiovascular Research DZHKPartner Site Munich Heart Alliance80336BerlinGermany
| | - Jessica Pauli
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
- German Center for Cardiovascular Research DZHKPartner Site Munich Heart Alliance80336BerlinGermany
| | - Greg Winski
- Department of Medicine, Cardiovascular UnitKarolinska Institute171 77StockholmSweden
| | - Zhiyuan Wu
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
- Department of Vascular SurgeryBeijing HospitalNational Center of GerontologyInstitute of Geriatric MedicineChinese Academy of Medical ScienceBeijing10073P. R. China
| | - Zhaolong Li
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
| | - Lorenzo Botti
- Department of Engineering and Applied SciencesUniversity of BergamoBergamo24129Italy
| | - Sandro Meucci
- Micronit MicrotechnologiesEnschede15 7521The Netherlands
| | - Pierangelo Conti
- Department of Engineering and Applied SciencesUniversity of BergamoBergamo24129Italy
| | | | - Nadiya Glukha
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
| | - Nora Hummel
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
| | - Albert Busch
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
- Division of Vascular and Endovascular SurgeryDepartment for VisceralThoracic and Vascular SurgeryMedical Faculty Carl Gustav Carus and University HospitalTechnical University Dresden01069DresdenGermany
| | | | - Hong Jin
- Department of Medicine, Cardiovascular UnitKarolinska Institute171 77StockholmSweden
| | - Nadja Sachs
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
| | - Hans‐Henning Eckstein
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
| | - Anne Dueck
- German Center for Cardiovascular Research DZHKPartner Site Munich Heart Alliance80336BerlinGermany
- Institute of Pharmacology and ToxicologyTechnical University of Munich80333MunichGermany
| | - Reinier A. Boon
- Department of PhysiologyAmsterdam Cardiovascular Sciences (ACS)Amsterdam UMCVU University Medical CenterAmsterdam1081 HVThe Netherlands
- Institute of Cardiovascular RegenerationCenter of Molecular MedicineGoethe‐University60323FrankfurtGermany
- German Center for Cardiovascular Research DZHKPartner Site Frankfurt Rhine‐Main10785BerlinGermany
| | - Andreas R. Bausch
- Department of Cellular BiophysicsTechnical University of Munich80333MunichGermany
| | - Lars Maegdefessel
- Department for Vascular and Endovascular SurgeryTechnical University of Munich80333MunichGermany
- German Center for Cardiovascular Research DZHKPartner Site Munich Heart Alliance80336BerlinGermany
- Department of Medicine, Cardiovascular UnitKarolinska Institute171 77StockholmSweden
| |
Collapse
|
7
|
Aalbregt E, Rijken L, Nederveen A, van Ooij P, Yeung KK, Jongkind V. Quantitative Magnetic Resonance Imaging to Assess Progression and Rupture Risk of Aortic Aneurysms: A Scoping Review. J Endovasc Ther 2023:15266028231204830. [PMID: 37853734 DOI: 10.1177/15266028231204830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
PURPOSE In current practice, the diameter of an aortic aneurysm is utilized to estimate the rupture risk and decide upon timing of elective repair, although it is known to be imprecise and not patient-specific. Quantitative magnetic resonance imaging (MRI) enables the visualization of several biomarkers that provide information about processes within the aneurysm and may therefore facilitate patient-specific risk stratification. We performed a scoping review of the literature on quantitative MRI techniques to assess aortic aneurysm progression and rupture risk, summarized these findings, and identified knowledge gaps. METHODS Literature concerning primary research was of interest and the medical databases PubMed, Scopus, Embase, and Cochrane were systematically searched. This study used the PRISMA protocol extension for scoping reviews. Articles published between January 2010 and February 2023 involving animals and/or humans were included. Data were extracted by 2 authors using a predefined charting method. RESULTS A total of 1641 articles were identified, of which 21 were included in the scoping review. Quantitative MRI-derived biomarkers were categorized into hemodynamic (8 studies), wall (5 studies) and molecular biomarkers (8 studies). Fifteen studies included patients and/or healthy human subjects. Animal models were investigated in the other 6 studies. A cross-sectional study design was the most common, whereas 5 animal studies had a longitudinal component and 2 studies including patients had a prospective design. A promising hemodynamic biomarker is wall shear stress (WSS), which is estimated based on 4D-flow MRI. Molecular biomarkers enable the assessment of inflammatory and wall deterioration processes. The ADAMTS4-specific molecular magnetic resonance (MR) probe showed potential to predict abdominal aortic aneurysm (AAA) formation and rupture in a murine model. Wall biomarkers assessed using dynamic contrast-enhanced (DCE) MRI showed great potential for assessing AAA progression independent of the maximum diameter. CONCLUSION This scoping review provides an overview of quantitative MRI techniques studied and the biomarkers derived from them to assess aortic aneurysm progression and rupture risk. Longitudinal studies are needed to validate the causal relationships between the identified biomarkers and aneurysm growth, rupture, or repair. In the future, quantitative MRI could play an important role in the personalized risk assessment of aortic aneurysm rupture. CLINICAL IMPACT The currently used maximum aneurysm diameter fails to accurately assess the multifactorial pathology of an aortic aneurysm and precisely predicts rupture in a patient-specific manner. Quantitative magnetic resonance imaging (MRI) enables the detection of various quantitative parameters involved in aneurysm progression and subsequent rupture. This scoping review provides an overview of the studied quantitative MRI techniques, the biomarkers derived from them, and recommendations for future research needed for the implementation of these biomarkers. Ultimately, quantitative MRI could facilitate personalized risk assessment for patients with aortic aneurysms, thereby reducing untimely repairs and improving rupture prevention.
Collapse
Affiliation(s)
- Eva Aalbregt
- Department of Surgery, Amsterdam UMC location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Department of Radiology and Nuclear Medicine, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Lotte Rijken
- Department of Surgery, Amsterdam UMC location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Aart Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Kak Khee Yeung
- Department of Surgery, Amsterdam UMC location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Vincent Jongkind
- Department of Surgery, Amsterdam UMC location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
- Amsterdam UMC, location AMC, Amsterdam, The Netherlands
| |
Collapse
|
8
|
Hyodo R, Takehara Y, Mizuno T, Ichikawa K, Horiguchi R, Kawakatsu S, Mizuno T, Ebata T, Naganawa S, Jin N, Ichiba Y. Four-dimensional Flow MRI Assessment of Portal Hemodynamics and Hepatic Regeneration after Portal Vein Embolization. Radiology 2023; 308:e230709. [PMID: 37750777 DOI: 10.1148/radiol.230709] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Background Percutaneous transhepatic portal vein (PV) embolization (PVE) is a standard preoperative procedure for advanced biliary cancer when the future liver remnant (FLR) is insufficient, yet the effect of this procedure on portal hemodynamics is still unclear. Purpose To assess whether four-dimensional (4D) MRI flowmetry can be used to estimate FLR volume and to identify the optimal time for this measurement. Materials and Methods This prospective single-center study enrolled consecutive adult patients with biliary cancer who underwent percutaneous transhepatic PVE for the right liver between June 2020 and November 2022. Portal hemodynamics were assessed using 4D flow MRI before PVE and within 1 day (0-day group) or 3-4 days (3-day group) after PVE. FLR volume was measured using CT before PVE and after PVE but before surgery. Blood flow changes were analyzed with the Wilcoxon signed rank test, and correlations with Spearman rank correlation. Results The 0-day group included 24 participants (median age, 72 years [IQR, 69-77 years]; 17 male participants), and the 3-day group included 13 participants (median age, 71 years [IQR, 68-78 years]; eight male participants). Both groups showed increased left PV (LPV) flow rate after PVE (0-day group: from median 3.72 mL/sec [IQR, 2.83-4.55 mL/sec] to 9.48 mL/sec [IQR, 8.12-10.7 mL/sec], P < .001; 3-day group: from median 3.65 mL/sec [IQR, 2.14-3.79 mL/sec] to 8.16 mL/sec [IQR, 6.82-8.98 mL/sec], P < .001). LPV flow change correlated with FLR volume change relative to the number of days from PVE to presurgery CT only in the 3-day group (ρ = 0.62, P = .02; 0-day group, P = .11). The output of the regression equation for estimating presurgery FLR volume correlated with CT-measured volume (ρ = 0.78; P = .002). Conclusion Four-dimensional flow MRI demonstrated increased blood flow in residual portal branches 3-4 days after PVE, offering insights for estimating presurgery FLR volume. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Roldán-Alzate and Oechtering in this issue.
Collapse
Affiliation(s)
- Ryota Hyodo
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Yasuo Takehara
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Takashi Mizuno
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Kazushige Ichikawa
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Ryota Horiguchi
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Shoji Kawakatsu
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Takashi Mizuno
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Tomoki Ebata
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Shinji Naganawa
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Ning Jin
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| | - Yoshito Ichiba
- From the Department of Radiology (R. Hyodo, Y.T., S.N.), Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging (Y.T.), and Department of Surgery (S.K., T.M.[2], T.E.), Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan (T.M.[1], K.I.); Department of Radiology, Yokkaichi Municipal Hospital, Yokkaichi, Japan (R. Horiguchi); Siemens Medical Solutions USA, Malvern, Pa (J.N.); and Siemens Healthcare, Tokyo, Japan (Y.I.)
| |
Collapse
|
9
|
Ding J, Du Y, Zhao R, Yang Q, Zhu L, Tong Y, Wen C, Wang M. Detection of Abnormal Wall Shear Stress and Oscillatory Shear Index via Ultrasound Vector Flow Imaging as Possible Indicators for Arteriovenous Fistula Stenosis in Hemodialysis. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1830-1836. [PMID: 37270353 DOI: 10.1016/j.ultrasmedbio.2023.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 04/19/2023] [Accepted: 04/21/2023] [Indexed: 06/05/2023]
Abstract
OBJECTIVE The arteriovenous fistula (AVF) is an essential vascular access for hemodialysis patients. AVF stenosis may occur at sites with abnormal wall shear stress (WSS) and oscillatory shear index (OSI), which are caused by the complex flow in the AVF. At present, an effective method for rapid determination of the WSS and OSI of the AVF is lacking. The objective of this study was to apply an ultrasound-based method for determination of the WSS and OSI to explore the risk sites of the AVF. METHODS In this study, the ultrasound vector flow imaging technique V Flow was applied to measure the WSS and OSI at four different regions of the AVF to detect and analyze the risk sites: (i) anastomosis region, (ii) curved region, (iii) proximal vein and (iv) distal vein. Twenty-one patients were included in this study. The relative residence time was calculated based on the measured WSS and OSI. RESULTS The curved region had the lowest WSS; the anastomosis region had a significantly higher OSI (p < 0.05) compared with the venous regions, and the curved region had a significantly higher RRT (p < 0.05) compared with the proximal vein region. CONCLUSION V Flow is a feasible tool for studying WSS variations in AVF. The possible risk site in the AVF may be located in the anastomosis and curved regions, where the latter could present a higher risk for AVF stenosis.
Collapse
Affiliation(s)
- Jiaxiang Ding
- Peking University International Hospital, Beijing, China.
| | - Yigang Du
- Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Rui Zhao
- Peking University International Hospital, Beijing, China
| | - Qinghua Yang
- Peking University International Hospital, Beijing, China
| | - Lei Zhu
- Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Yisha Tong
- Department of Vascular Surgery, Austin Hospital, University of Melbourne, Melbourne, Australia
| | - Chaoyang Wen
- Peking University International Hospital, Beijing, China
| | - Mei Wang
- Peking University International Hospital, Beijing, China
| |
Collapse
|
10
|
Hanna L, Gibbs RGJ. Risk Prediction for Abdominal Aortic Aneurysms: One Size Does Not Fit All. Is it Time to go with the Flow of Hotspots? Eur J Vasc Endovasc Surg 2023; 65:612-613. [PMID: 36682401 DOI: 10.1016/j.ejvs.2023.01.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/21/2022] [Accepted: 01/12/2023] [Indexed: 01/21/2023]
Affiliation(s)
- Lydia Hanna
- Department of Surgery and Cancer, Imperial College London, London, UK; Imperial Vascular Unit, Imperial Healthcare NHS Trust, London, UK.
| | - Richard G J Gibbs
- Department of Surgery and Cancer, Imperial College London, London, UK; Imperial Vascular Unit, Imperial Healthcare NHS Trust, London, UK
| |
Collapse
|
11
|
Horiguchi R, Takehara Y, Sugiyama M, Hyodo R, Komada T, Matsushima M, Naganawa S, Mizuno T, Sakurai Y, Sugimoto M, Banno H, Komori K, Itatani K. Postendovascular Aneurysmal Repair Increase in Local Energy Loss for Fusiform Abdominal Aortic Aneurysm: Assessments With 4D flow MRI. J Magn Reson Imaging 2023; 57:1199-1211. [PMID: 35861188 DOI: 10.1002/jmri.28359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 07/05/2022] [Accepted: 07/05/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Although endovascular aneurysmal repair (EVAR) is a preferred treatment for abdominal aortic aneurysm (AAA) owing to its low invasiveness, its impact on the local hemodynamics has not been fully assessed. PURPOSE To elucidate how EVAR affects the local hemodynamics in terms of energy loss (EL). STUDY TYPE Prospective single-arm study. FIELD STRENGTH/SEQUENCE A 3.0 T/4D flow MRI using a phase-contrast three-dimensional cine-gradient-echo sequence. POPULATION A total of 13 consecutive patients (median [interquartile range] age: 77.0 [73.0, 78.8] years, 11 male) scheduled for EVAR as an initial treatment for fusiform AAA. ASSESSMENT 4D flow MRI covering the abdominal aorta and bilateral common iliac arteries and the corresponding stent-graft (SG) lumen was performed before and after EVAR. Plasma brain natriuretic peptide (BNP) was measured within 1 week before and 1 month after EVAR. The hemodynamic data, including mean velocity and the local EL, were compared pre-/post-EVAR. EL was correlated with AAA neck angle and with BNP. Patients were subdivided into deformed (N = 5) and undeformed SG subgroups (N = 8) and pre-/post-EVAR BNP compared in each. STATISTICS Parametric or nonparametric methods. Spearman's rank correlation coefficients (r). The interobserver/intraobserver variabilities with Bland-Altman plots. A P value < 0.05 is considered significant. RESULTS The mean velocity (cm/sec) at the AAA was five times greater after EVAR: 4.79 ± 0.32 vs. 0.91 ± 0.02. The total EL (mW) increased by 1.7 times after EVAR: 0.487 (0.420, 0.706) vs. 0.292 (0.192, 0.420). The total EL was proportional to the AAA neck angle pre-EVAR (r = 0.691) and post-EVAR (r = 0.718). BNP (pg/mL) was proportional to the total EL post-EVAR (r = 0.773). In the deformed SG group, EL (0.349 [0.261, 0.416]) increased 2.4-fold to 0.848 (0.597, 1.13), and the BNP 90.3 (53.6, 105) to 100 (67.2, 123) post-EVAR. CONCLUSION The local EL showed a 1.7-fold increase after EVAR. The larger increase in the EL in the deformed SG group might be a potential concern for frail patients. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Ryota Horiguchi
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Yasuo Takehara
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.,Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Masataka Sugiyama
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Ryota Hyodo
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Tomohiro Komada
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Masaya Matsushima
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Shinji Naganawa
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Takashi Mizuno
- Department of Medical Technology, Nagoya University Hospital, Nagoya, Aichi, Japan
| | - Yasuo Sakurai
- Department of Medical Technology, Nagoya University Hospital, Nagoya, Aichi, Japan
| | - Masayuki Sugimoto
- Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Hiroshi Banno
- Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Kimihiro Komori
- Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Keiichi Itatani
- Department of Cardiovascular Surgery, Osaka City University, Osaka, Japan
| |
Collapse
|
12
|
Fu M, Peng F, Niu H, He X, Chen S, Zhang M, Xia J, Wang Y, Xu B, Liu A, Li R. Inflow Angle Impacts Morphology, Hemodynamics, and Inflammation of Side-wall Intracranial Aneurysms. J Magn Reson Imaging 2023; 57:113-123. [PMID: 35652452 DOI: 10.1002/jmri.28234] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 05/06/2022] [Accepted: 05/06/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Aneurysm inflow angle has been shown to be associated with hemodynamic changes by computational fluid dynamics. However, these studies were based on single aneurysm model and were limited to side-wall aneurysms. PURPOSE To investigate the association between inflow angle and morphology, hemodynamic, and inflammation of intracranial side-wall and bifurcation aneurysms. STUDY TYPE Prospective. POPULATION A total of 62 patients (aged 58.34 ± 12.39, 44 female) with 59 unruptured side-wall aneurysms and 17 unruptured bifurcation aneurysms were included. FIELD STRENGTH/SEQUENCE A 3.0 T; 3D fast field echo sequence (TOF-MRA); free-breathing, 3D radio-frequency-spoiled, multi-shot turbo field echo sequence (4D-flow MRI); 3D black-blood T1-weighted volumetric turbo spin echo acquisition sequence (T1 -VISTA) ASSESSMENT: Two neuroradiologists assessed the inflow angle and size for intracranial aneurysms in 3D space with TOF-MRA images. The average and maximum inflow velocity (Vavg-IA , Vmax-IA ), blood flow (Flowavg-IA , Flowmax-IA ), and average wall shear stress (WSSavg-IA ) for aneurysms were assessed from 4D-flow MRI in regions of interest drawn by two neuroradiologists. The aneurysmal wall enhancement (AWE) grades between precontrast and postcontrast T1 -VISTA images were evaluated by three neuroradiologists. STATISTICAL TESTS Kruskal-Wallis H test, χ2 test, Pearson's correlation coefficient, scatter plots and regression lines, multivariate logistic regression analysis (partial correlation r) were performed. A P < 0.05 was considered statistically significant. RESULTS The WSSavg-IA (0.52 ± 0.34 vs. 0.27 ± 0.22) and AWE grades (1.38 ± 1.04 vs. 2.02 ± 0.68) between the two inflow angle subgroups of side-wall aneurysms were significantly different. The aneurysm size (rs = 0.31), WSSavg-IA (rs = -0.45), and AWE grades (rs = 0.45) were significantly correlated with inflow angle in side-wall aneurysms. While in bifurcation aneurysms, there were no significant associations between inflow angle and size (P = 0.901), Vavg-IA (P = 0.699), Vmax-IA (P = 0.482), Flowavg-IA (P = 0.550), Flowmax-IA (P = 0.689), WSSavg-IA (P = 0.573), and AWE grades (P = 0.872). DATA CONCLUSION A larger aneurysm size, a lower WSS and a higher AWE grade were correlated with a larger inflow angle in side-wall aneurysms. EVIDENCE LEVEL 3 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Mingzhu Fu
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Fei Peng
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
| | - Hao Niu
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
| | - Xiaoxin He
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
| | - Shuo Chen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Miaoqi Zhang
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Jiaxiang Xia
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
| | | | - Boya Xu
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
| | - Aihua Liu
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
| | - Rui Li
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China
| |
Collapse
|
13
|
Hyodo R, Takehara Y, Naganawa S. 4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications. Radiol Med 2022; 127:1181-1198. [PMID: 36123520 PMCID: PMC9587937 DOI: 10.1007/s11547-022-01553-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 08/29/2022] [Indexed: 02/07/2023]
Abstract
Thus far, ultrasound, CT, and 2D cine phase-contrast MRI has been adopted to evaluate blood flow and vascular morphology in the portal venous system; however, all these techniques have some shortcomings, such as limited field of view and difficulty in accurately evaluating blood flow. A new imaging technique, namely 3D cine phase-contrast (4D Flow) MRI, can acquire blood flow data of the entire abdomen at once and in a time-resolved manner, allowing visual, quantitative, and comprehensive assessment of blood flow in the portal venous system. In addition, a retrospective blood flow analysis, i.e., "retrospective flowmetry," is possible. Although the development of 4D Flow MRI for the portal system has been delayed compared to that for the arterial system owing to the lower flow velocity of the portal venous system and the presence of respiratory artifacts, several useful reports have recently been published as the technology has advanced. In the first part of this narrative review article, technical considerations of image acquisition and analysis methods of 4D Flow MRI for the portal venous system and the validations of their results are described. In the second part, the current clinical application of 4D Flow MRI for the portal venous system is reviewed.
Collapse
Affiliation(s)
- Ryota Hyodo
- Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan.
| | - Yasuo Takehara
- Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
- Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Shinji Naganawa
- Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| |
Collapse
|
14
|
Oechtering TH, Roberts GS, Panagiotopoulos N, Wieben O, Roldán-Alzate A, Reeder SB. Abdominal applications of quantitative 4D flow MRI. Abdom Radiol (NY) 2022; 47:3229-3250. [PMID: 34837521 PMCID: PMC9135957 DOI: 10.1007/s00261-021-03352-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 11/11/2021] [Accepted: 11/12/2021] [Indexed: 01/18/2023]
Abstract
4D flow MRI is a quantitative MRI technique that allows the comprehensive assessment of time-resolved hemodynamics and vascular anatomy over a 3-dimensional imaging volume. It effectively combines several advantages of invasive and non-invasive imaging modalities like ultrasound, angiography, and computed tomography in a single MRI acquisition and provides an unprecedented characterization of velocity fields acquired non-invasively in vivo. Functional and morphological imaging of the abdominal vasculature is especially challenging due to its complex and variable anatomy with a wide range of vessel calibers and flow velocities and the need for large volumetric coverage. Despite these challenges, 4D flow MRI is a promising diagnostic and prognostic tool as many pathologies in the abdomen are associated with changes of either hemodynamics or morphology of arteries, veins, or the portal venous system. In this review article, we will discuss technical aspects of the implementation of abdominal 4D flow MRI ranging from patient preparation and acquisition protocol over post-processing and quality control to final data analysis. In recent years, the range of applications for 4D flow in the abdomen has increased profoundly. Therefore, we will review potential clinical applications and address their clinical importance, relevant quantitative and qualitative parameters, and unmet challenges.
Collapse
Affiliation(s)
- Thekla H. Oechtering
- University of Wisconsin, Department of Radiology, Madison, WI, United States,Universität zu Lübeck, Department of Radiology, Luebeck, Germany
| | - Grant S. Roberts
- University of Wisconsin, Department of Medical Physics, Madison, WI, United States
| | - Nikolaos Panagiotopoulos
- University of Wisconsin, Department of Radiology, Madison, WI, United States,Universität zu Lübeck, Department of Radiology, Luebeck, Germany
| | - Oliver Wieben
- University of Wisconsin, Department of Radiology, Madison, WI, United States,University of Wisconsin, Department of Medical Physics, Madison, WI, United States
| | - Alejandro Roldán-Alzate
- University of Wisconsin, Department of Radiology, Madison, WI, United States,University of Wisconsin, Department of Mechanical Engineering, Madison, WI, United States,University of Wisconsin, Department of Biomedical Engineering, Madison, WI, United States
| | - Scott B. Reeder
- University of Wisconsin, Department of Radiology, Madison, WI, United States,University of Wisconsin, Department of Medical Physics, Madison, WI, United States,University of Wisconsin, Department of Mechanical Engineering, Madison, WI, United States,University of Wisconsin, Department of Biomedical Engineering, Madison, WI, United States,University of Wisconsin, Department of Emergency Medicine, Madison, WI, United States
| |
Collapse
|
15
|
Fu M, Peng F, Zhang M, Chen S, Niu H, He X, Xu B, Liu A, Li R. Aneurysmal wall enhancement and hemodynamics: pixel-level correlation between spatial distribution. Quant Imaging Med Surg 2022; 12:3692-3704. [PMID: 35782262 PMCID: PMC9246729 DOI: 10.21037/qims-21-1203] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Accepted: 03/29/2022] [Indexed: 03/22/2024]
Abstract
BACKGROUND Inflammation and hemodynamics are interrelated risk factors for intracranial aneurysm rupture. This study aimed to identify the relationship between these risk factors from an individual-patient perspective using biomarkers of aneurysm wall enhancement (AWE) derived from high-resolution magnetic resonance imaging (HR-MRI) and hemodynamic parameters by four-dimensional flow MRI (4D-flow MRI). METHODS A total of 29 patients with 29 unruptured intracranial aneurysms larger than 4 mm were included in this prospective cross-sectional study. A total of 24 aneurysms had AWE and 5 did not have AWE. A three-dimensional (3D) vessel model of each individual aneurysm was generated with 3D time-of-flight magnetic resonance angiography (3D TOF-MRA). Quantification of AWE was sampled with HR-MRI. Time-averaged wall shear stress (WSS) and oscillatory shear index (OSI) were calculated from the 4D-flow MRI. The correlation between spatial distribution of AWE and hemodynamic parameters measured at pixel-level was evaluated for each aneurysm. RESULTS In aneurysms with AWE, the spatial distribution of WSS was negatively correlated with AWE in 100% (24/24) of aneurysms, though 2 had an absolute value of the correlation coefficient <0.1. The OSI was positively correlated with AWE in 91.7% (22/24) of aneurysms; the other 2 aneurysms showed a negative correlation with AWE. In aneurysms with no AWE, there was no correlation between WSS (100%, 5/5), OSI (80%, 4/5), and wall inflammation. CONCLUSIONS The spatial distribution of WSS was negatively correlated with AWE in aneurysms with AWE, and OSI was positively correlated with AWE in most aneurysms with AWE. While aneurysms that did not contain AWE showed no correlation between hemodynamics and wall inflammation.
Collapse
Affiliation(s)
- Mingzhu Fu
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Fei Peng
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
- China National Clinical Research Center for Neurological Diseases, Beijing, China
| | - Miaoqi Zhang
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Shuo Chen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Hao Niu
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
- China National Clinical Research Center for Neurological Diseases, Beijing, China
| | - Xiaoxin He
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
- China National Clinical Research Center for Neurological Diseases, Beijing, China
| | - Boya Xu
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
- China National Clinical Research Center for Neurological Diseases, Beijing, China
| | - Aihua Liu
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Beijing, China
- China National Clinical Research Center for Neurological Diseases, Beijing, China
| | - Rui Li
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| |
Collapse
|
16
|
Trenti C, Ziegler M, Bjarnegård N, Ebbers T, Lindenberger M, Dyverfeldt P. Wall shear stress and relative residence time as potential risk factors for abdominal aortic aneurysms in males: a 4D flow cardiovascular magnetic resonance case-control study. J Cardiovasc Magn Reson 2022; 24:18. [PMID: 35303893 PMCID: PMC8932193 DOI: 10.1186/s12968-022-00848-2] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 02/17/2022] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Abdominal aortic aneurysms (AAA) can lead to catastrophic events such as dissection or rupture, and are an expression of general aortic disease. Low wall shear stress (WSS), high oscillatory shear index (OSI), and high relative residence time (RRT) have been correlated against increased uptake of inflammatory markers in the vessel wall and may improve risk stratification of AAA. We sought to obtain a comprehensive view of WSS, OSI, and RRT in the whole aorta for patients with AAA and age-matched elderly controls and young normal controls. METHODS 4D Flow cardiovascular magnetic resonance images of the whole aorta were acquired in 18 AAA patients (70.8 ± 3.4 years), 22 age-matched controls (71.4 ± 3.4 years), and 23 young subjects (23.3 ± 3.1 years), all males. Three-dimensional segmentations of the whole aorta were created for all timeframes using a semi-automatic approach. The aorta was divided into five segments: ascending aorta, arch, descending aorta, suprarenal and infrarenal abdominal aorta. For each segment, average values of peak WSS, OSI, and RRT were computed. Student's t-tests were used to compare values between the three cohorts (AAA patients vs elderly controls, and elderly controls vs young controls) where the data were normally distributed, and the non-parametric Wilcoxon rank sum tests were used otherwise. RESULTS AAA patients had lower peak WSS in the descending aorta as well as in the abdominal aorta compared to elderly controls (p ≤ 0.001), similar OSI, but higher RRT in the descending and abdominal aorta (p ≤ 0.001). Elderly controls had lower peak WSS compared to young controls throughout the aorta (p < 0.001), higher OSI in all segments except for the infrarenal aorta (p < 0.001), and higher RRT throughout the aorta, except the infrarenal aorta (p < 0.001). CONCLUSIONS This study provides novel insights into WSS, OSI, and RRT in patients with AAA in relation to normal ageing, highlighting how AAA patients have markedly abnormal hemodynamic stresses not only in the infrarenal, but in the entire aorta. Moreover, we identified RRT as a marker for abnormal AAA hemodynamics. Further investigations are needed to explore if RRT or other measures of hemodynamics stresses best predict AAA growth and/or rupture.
Collapse
Affiliation(s)
- Chiara Trenti
- Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
| | - Magnus Ziegler
- Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Niclas Bjarnegård
- Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Marcus Lindenberger
- Department of Cardiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Petter Dyverfeldt
- Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
17
|
Takahashi K, Sekine T, Ando T, Ishii Y, Kumita S. Utility of 4D Flow MRI in Thoracic Aortic Diseases: A Literature Review of Clinical Applications and Current Evidence. Magn Reson Med Sci 2022; 21:327-339. [PMID: 34497166 PMCID: PMC9680552 DOI: 10.2463/mrms.rev.2021-0046] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 07/17/2021] [Indexed: 11/09/2022] Open
Abstract
Despite the recent technical developments, surgery on the thoracic aorta remains challenging and is associated with significant mortality and morbidity. Decisions about when and if to operate are based on a balance between surgical risk and the hazard of aortic rupture. These decisions are sometimes difficult in elective cases of thoracic aortic diseases, including aneurysms and dissections. Abnormal wall stress derived from flow alterations influences disease progression. Therefore, a better understanding of the complex hemodynamic environment inside the aortic lumen will facilitate patient-specific risk assessments of complications, which enable clinicians to provide timely prophylactic interventions. Time-resolved 3D phase-contrast (4D flow) MRI has many advantages for the in vivo assessment of flow dynamics. Recent developments in 4D flow imaging techniques has led to significant advances in our understanding of physiological flow dynamics in healthy subjects and patients with thoracic aortic diseases. In this clinically focused review of thoracic aortic diseases, we demonstrate the clinical advances acquired with 4D flow MRI from published studies. We provide a systematic overview of key evidences and considerations regarding normal thoracic aortas, thoracic aortic aneurysms, aortic dissections, and thoracic aortas with prosthetic graft replacement.
Collapse
Affiliation(s)
| | - Tetsuro Sekine
- Department of Radiology, Nippon Medical School Musashi Kosugi Hospital, Kawasaki, Kanagawa, Japan
| | - Takahiro Ando
- Department of Radiology, Nippon Medical School, Tokyo, Japan
| | - Yosuke Ishii
- Department of Cardiovascular Surgery, Nippon Medical School, Tokyo, Japan
| | | |
Collapse
|
18
|
Takehara Y. Clinical Application of 4D Flow MR Imaging for the Abdominal Aorta. Magn Reson Med Sci 2022; 21:354-364. [PMID: 35185062 PMCID: PMC9680546 DOI: 10.2463/mrms.rev.2021-0156] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Accepted: 01/05/2022] [Indexed: 07/30/2023] Open
Abstract
Blood vessels can be regarded as autonomous organs. The endothelial cells on the vessel surface serve as mechanosensors or mechanoreceptors for the flow velocity and turbulence of the blood flow in terms of wall shear stress (WSS), thereby monitoring changes in the flow velocity. Accordingly, the endothelial cells regulate the flow velocity by releasing numerous mediators. Such regulatory systems also trigger atherosclerosis, where the WSS decreases or fluctuates to maintain the flow velocity or local WSS. As occurrences of abdominal aortic aneurysms and aortic dissection are closely related to atherosclerosis, understanding the hemodynamics of the abdominal aorta is necessary to obtain useful information concerning the pathogenesis, diagnosis, and interventions. 4D flow MRI is beneficial for measuring the hemodynamics through comprehensive retrospective flowmetry of the entire spatio-temporal distributions of the flow vectors. This section focuses on abdominal aortic aneurysms and aortic dissection as representative examples of abdominal aortic diseases. Their hemodynamic characteristics and how hemodynamics is involved in their progression are described, and how 4D flow MRI can contribute to their assessment is also explained.
Collapse
Affiliation(s)
- Yasuo Takehara
- Departments of Fundamental Development for Low Invasive Diagnostic Imaging and Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| |
Collapse
|
19
|
Terada M, Takehara Y, Isoda H, Wakayama T, Nozaki A. Technical Background for 4D Flow MR Imaging. Magn Reson Med Sci 2022; 21:267-277. [PMID: 35153275 PMCID: PMC9680548 DOI: 10.2463/mrms.rev.2021-0104] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 11/20/2021] [Indexed: 10/27/2023] Open
Abstract
Recently, the hemodynamic assessments with 3D cine phase-contrast (PC) MRI (4D flow MRI) have attracted considerable attention from clinicians. Unlike 2D cine PC MRI, the technique allows for cardiac phase-resolved data acquisitions of flow velocity vectors within the entire FOV during a clinically viable period. Thus, the method has enabled retrospective flowmetry in the spatial and temporal axes, which are essential to derive hemodynamic parameters related to vascular homeostasis and those to the progression of the pathologies. Accelerations in imaging are critical for this technology to be clinically viable; however, a high SNR or velocity-to-noise ratio (VNR) is also vital for accurate flow measurements. In this chapter, the technologies enabling this difficult balance are discussed.
Collapse
Affiliation(s)
- Masaki Terada
- Department of Diagnostic Radiologic Technology, Iwata City Hospital, Iwata, Shizuoka, Japan
| | - Yasuo Takehara
- Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Haruo Isoda
- Department of Brain & Mind Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | | | - Atsushi Nozaki
- MR Applications and Workflow, GE Healthcare Japan, Tokyo, Japan
| |
Collapse
|
20
|
Isoda H, Fukuyama A. Quality Control for 4D Flow MR Imaging. Magn Reson Med Sci 2022; 21:278-292. [PMID: 35197395 PMCID: PMC9680545 DOI: 10.2463/mrms.rev.2021-0165] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 01/08/2022] [Indexed: 01/06/2023] Open
Abstract
In recent years, 4D flow MRI has become increasingly important in clinical applications for the blood vessels in the whole body, heart, and cerebrospinal fluid. 4D flow MRI has advantages over 2D cine phase-contrast (PC) MRI in that any targeted area of interest can be analyzed post-hoc, but there are some factors to be considered, such as ensuring measurement accuracy, a long imaging time and post-processing complexity, and interobserver variability.Due to the partial volume phenomenon caused by low spatial and temporal resolutions, the accuracy of flow measurement in 4D flow MRI is reduced. For spatial resolution, it is recommended to include at least four voxels in the vessel of interest, and if possible, six voxels. In large vessels such as the aorta, large voxels can be secured and SNR can be maintained, but in small cerebral vessels, SNR is reduced, resulting in reduced accuracy. A temporal resolution of less than 40 ms is recommended. The velocity-to-noise ratio (VNR) of low-velocity blood flow is low, resulting in poor measurement accuracy. The use of dual velocity encoding (VENC) or multi-VENC is recommended to avoid velocity wrap around and to increase VNR. In order to maintain sufficient spatio-temporal resolution, a longer imaging time is required, leading to potential patient movement during examination and a corresponding decrease in measurement accuracy.For the clinical application of new technologies, including various acceleration techniques, in vitro and in vivo accuracy verification based on existing accuracy-validated 2D cine PC MRI and 4D flow MRI, as well as accuracy verification on the conservation of mass' principle, should be performed, and intraobserver repeatability, interobserver reproducibility, and test-retest reproducibility should be checked.
Collapse
Affiliation(s)
- Haruo Isoda
- Brain and Mind Research Center, Nagoya University, Nagoya, Aichi, Japan
- Biomedical Imaging Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Atsushi Fukuyama
- Faculty of Health Sciences, Department of Radiological Sciences, Japan Healthcare University, Sapporo, Hokkaido, Japan
| |
Collapse
|
21
|
Ferdian E, Dubowitz DJ, Mauger CA, Wang A, Young AA. WSSNet: Aortic Wall Shear Stress Estimation Using Deep Learning on 4D Flow MRI. Front Cardiovasc Med 2022; 8:769927. [PMID: 35141290 PMCID: PMC8818720 DOI: 10.3389/fcvm.2021.769927] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 11/30/2021] [Indexed: 11/13/2022] Open
Abstract
Wall shear stress (WSS) is an important contributor to vessel wall remodeling and atherosclerosis. However, image-based WSS estimation from 4D Flow MRI underestimates true WSS values, and the accuracy is dependent on spatial resolution, which is limited in 4D Flow MRI. To address this, we present a deep learning algorithm (WSSNet) to estimate WSS trained on aortic computational fluid dynamics (CFD) simulations. The 3D CFD velocity and coordinate point clouds were resampled into a 2D template of 48 × 93 points at two inward distances (randomly varied from 0.3 to 2.0 mm) from the vessel surface (“velocity sheets”). The algorithm was trained on 37 patient-specific geometries and velocity sheets. Results from 6 validation and test cases showed high accuracy against CFD WSS (mean absolute error 0.55 ± 0.60 Pa, relative error 4.34 ± 4.14%, 0.92 ± 0.05 Pearson correlation) and noisy synthetic 4D Flow MRI at 2.4 mm resolution (mean absolute error 0.99 ± 0.91 Pa, relative error 7.13 ± 6.27%, and 0.79 ± 0.10 Pearson correlation). Furthermore, the method was applied on in vivo 4D Flow MRI cases, effectively estimating WSS from standard clinical images. Compared with the existing parabolic fitting method, WSSNet estimates showed 2–3 × higher values, closer to CFD, and a Pearson correlation of 0.68 ± 0.12. This approach, considering both geometric and velocity information from the image, is capable of estimating spatiotemporal WSS with varying image resolution, and is more accurate than existing methods while still preserving the correct WSS pattern distribution.
Collapse
Affiliation(s)
- Edward Ferdian
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
- *Correspondence: Edward Ferdian
| | - David J. Dubowitz
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
| | - Charlene A. Mauger
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
| | - Alan Wang
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Alistair A. Young
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
- Department of Biomedical Engineering, King's College London, London, United Kingdom
- Alistair A. Young
| |
Collapse
|
22
|
Nishimura T, Sueyoshi E, Koike H, Uetani M. Initial experience with intensity distribution analysis of hemodynamic parameters in the thoracic aorta using four-dimensional magnetic resonance imaging: A comparison between groups with different ejection fractions. Medicine (Baltimore) 2022; 101:e28563. [PMID: 35029224 PMCID: PMC8757938 DOI: 10.1097/md.0000000000028563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 12/21/2021] [Indexed: 11/26/2022] Open
Abstract
The purpose of this study was to investigate whether there were significant differences in the intensity distributions of thoracic aorta hemodynamic parameters between groups with different ejection fractions (EF) using four-dimensional flow magnetic resonance imaging and to investigate the relationships between each parameter.A total of 26 patients, 13 each with EF of >60% and <30%, underwent cardiac four-dimensional flow magnetic resonance imaging (EF >60%: mean age: 54 ± 11.6 years, EF <30%: mean age: 49.2 ± 17.2 years). The thoracic aorta was divided into the proximal and distal ascending aorta (AAo), aortic arch, and the proximal and distal descending aorta, and each section was further divided into the anterior wall, posterior wall, lesser curvature, and greater curvature. The intensity distributions of wall shear stress (WSS), energy loss (EL), and vorticity (Vort) (hemodynamic parameters) and the concordance rates between these distributions were analyzed.The concordance rate between the intensity distributions of EL and Vort was high. Only the intensity distributions of EL and Vort in the distal AAo differed significantly between the groups (P < .001). In the EF >60% group, these intensity distributions showed higher values in the greater curvature of the AAo, whereas in the EF <30% group higher values were seen in the lesser curvature of the AAo.Although there was no significant intergroup difference in the WSS intensity distribution, in the EF <30% group the WSS intensity distribution tended to exhibit higher values in the lesser curvature of the distal AAo, and the WSS intensity distribution values for the greater curvature tended to gradually increase from the arch to the proximal descending aorta.The only significant differences between the EF groups were found in the intensity distributions of EL and Vort in the distal AAo. This suggests that the distributions of atherosclerosis may be EF-dependent.
Collapse
|
23
|
Bappoo N, Syed MBJ, Khinsoe G, Kelsey LJ, Forsythe RO, Powell JT, Hoskins PR, McBride OMB, Norman PE, Jansen S, Newby DE, Doyle BJ. Low Shear Stress at Baseline Predicts Expansion and Aneurysm-Related Events in Patients With Abdominal Aortic Aneurysm. Circ Cardiovasc Imaging 2021; 14:1112-1121. [PMID: 34875845 DOI: 10.1161/circimaging.121.013160] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Low shear stress has been implicated in abdominal aortic aneurysm (AAA) expansion and clinical events. We tested the hypothesis that low shear stress in AAA at baseline is a marker of expansion rate and future aneurysm-related events. METHODS Patients were imaged with computed tomography angiography at baseline and followed up every 6 months >24 months with ultrasound measurements of maximum diameter. From baseline computed tomography angiography, we reconstructed 3-dimensional models for automated computational fluid dynamics simulations and computed luminal shear stress. The primary composite end point was aneurysm repair and/or rupture, and the secondary end point was aneurysm expansion rate. RESULTS We included 295 patients with median AAA diameter of 49 mm (interquartile range, 43-54 mm) and median follow-up of 914 (interquartile range, 670-1112) days. There were 114 (39%) aneurysm-related events, with 13 AAA ruptures and 98 repairs (one rupture was repaired). Patients with low shear stress (<0.4 Pa) experienced a higher number of aneurysm-related events (44%) compared with medium (0.4-0.6 Pa; 27%) and high (>0.6 Pa; 29%) shear stress groups (P=0.010). This association was independent of known risk factors (adjusted hazard ratio, 1.72 [95% CI, 1.08-2.73]; P=0.023). Low shear stress was also independently associated with AAA expansion rate (β=+0.28 mm/y [95% CI, 0.02-0.53]; P=0.037). CONCLUSIONS We show for the first time that low shear stress (<0.4 Pa) at baseline is associated with both AAA expansion and future aneurysm-related events. Aneurysms within the lowest tertile of shear stress, versus those with higher shear stress, were more likely to rupture or reach thresholds for elective repair. Larger prospective validation trials are needed to confirm these findings and translate them into clinical management.
Collapse
Affiliation(s)
- Nikhilesh Bappoo
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and the UWA Centre for Medical Research (N.B., G.K., L.J.K., P.E.N., B.J.D.), The University of Western Australia, Perth.,School of Engineering (N.B., G.K., L.J.K., B.K.D.), The University of Western Australia, Perth
| | - Maaz B J Syed
- Centre for Cardiovascular Science, Queens Medical Research Institute, University of Edinburgh, United Kingdom (M.B.J.S., R.O.F., P.R.H., O.M.B.M., D.E.N., B.J.D.)
| | - Georgia Khinsoe
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and the UWA Centre for Medical Research (N.B., G.K., L.J.K., P.E.N., B.J.D.), The University of Western Australia, Perth.,School of Engineering (N.B., G.K., L.J.K., B.K.D.), The University of Western Australia, Perth
| | - Lachlan J Kelsey
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and the UWA Centre for Medical Research (N.B., G.K., L.J.K., P.E.N., B.J.D.), The University of Western Australia, Perth.,School of Engineering (N.B., G.K., L.J.K., B.K.D.), The University of Western Australia, Perth
| | - Rachael O Forsythe
- Centre for Cardiovascular Science, Queens Medical Research Institute, University of Edinburgh, United Kingdom (M.B.J.S., R.O.F., P.R.H., O.M.B.M., D.E.N., B.J.D.)
| | - Janet T Powell
- Vascular Surgery Research Group, Imperial College London, London, United Kingdom (J.T.P.)
| | - Peter R Hoskins
- Centre for Cardiovascular Science, Queens Medical Research Institute, University of Edinburgh, United Kingdom (M.B.J.S., R.O.F., P.R.H., O.M.B.M., D.E.N., B.J.D.).,Biomedical Engineering, Dundee University, United Kingdom (P.R.H.)
| | - Olivia M B McBride
- Centre for Cardiovascular Science, Queens Medical Research Institute, University of Edinburgh, United Kingdom (M.B.J.S., R.O.F., P.R.H., O.M.B.M., D.E.N., B.J.D.)
| | - Paul E Norman
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and the UWA Centre for Medical Research (N.B., G.K., L.J.K., P.E.N., B.J.D.), The University of Western Australia, Perth.,Medical School (P.E.N., S.J.), The University of Western Australia, Perth
| | - Shirley Jansen
- Medical School (P.E.N., S.J.), The University of Western Australia, Perth.,Heart and Vascular Research Institute, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Perth, Australia (S.J.).,Department of Vascular and Endovascular Surgery, Sir Charles Gairdner Hospital, Perth, Australia (S.J.).,Curtin Medical School, Curtin University, Perth, Australia (S.J.)
| | - David E Newby
- Centre for Cardiovascular Science, Queens Medical Research Institute, University of Edinburgh, United Kingdom (M.B.J.S., R.O.F., P.R.H., O.M.B.M., D.E.N., B.J.D.)
| | - Barry J Doyle
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and the UWA Centre for Medical Research (N.B., G.K., L.J.K., P.E.N., B.J.D.), The University of Western Australia, Perth.,School of Engineering (N.B., G.K., L.J.K., B.K.D.), The University of Western Australia, Perth.,Centre for Cardiovascular Science, Queens Medical Research Institute, University of Edinburgh, United Kingdom (M.B.J.S., R.O.F., P.R.H., O.M.B.M., D.E.N., B.J.D.).,Australian Research Council Centre for Personalised Therapeutics Technologies (B.J.D.)
| |
Collapse
|