1
|
Alzyoud K, Al-Murshedi S, England A. Effective dose and image quality for different patient sizes during AP upper abdominal radiography: A phantom study. Appl Radiat Isot 2023; 202:111060. [PMID: 37806283 DOI: 10.1016/j.apradiso.2023.111060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 09/17/2023] [Accepted: 09/28/2023] [Indexed: 10/10/2023]
Abstract
INTRODUCTION Undertaking medical imaging examinations on obese patients can present practical challenges. Choosing optimal imaging protocols can be difficult, especially when promoting the ALARA principle. The aim of this study was to assess the effects of increasing body part thickness on image quality (IQ) and effective dose (ED) during upper abdominal radiography. A secondary aim was to determine the optimum exposure settings for larger sized patients. METHODS Underweight, standard, overweight and obese abdomen sizes were simulated using an anthropomorphic upper abdomen phantom, without and with additional fat layers (6, 10 and 16 cm). Phantoms were imaged using a variety of tube potentials (70-110 kVp), automatic exposure control (AEC) and a source-to-image distance of 120 cm. IQ was assessed visually using a relative visual grading analysis (VGA) method. Radiation dose was evaluated by calculating the ED using the Monte Carlo PCXMC 2.0 computer program. RESULTS IQ values showed a statistical reduction (p = 0.006) with increasing phantom size across all examined tube potentials. The highest IQ scores (3.3, 2.8, 2.5 and 2.2, respectively) were obtained at 70/75 kVp for all phantom thicknesses. As tube potential increased the IQ was also shown to decrease. ED showed a statistically significant increase (p < 0.001) with increasing phantom thicknesses. CONCLUSION Higher EDs were evident when applying lower tube potentials. Using an AEC with high tube potentials (105/110 kVp) can lead to a considerable decrease in ED with acceptable IQ when undertaking upper abdomen radiography on patients with large body part thicknesses. IMPLICATION FOR PRACTICE Applying higher values of tube potentials for patients who have a thicker abdomen can lead to decreased ED.
Collapse
Affiliation(s)
- Kholoud Alzyoud
- Department of Medical Imaging, Faculty of Applied Health Science, The Hashemite University, P.O. Box 330127, Zarqa, 13133, Jordan.
| | - Sadeq Al-Murshedi
- AL-Zahraa University for Women, College of Health and Medical Technology, Karbala, Iraq
| | | |
Collapse
|
2
|
Neira-Castro S, Guiu-Souto J, Pardo-Montero J. Dosimetry in positron emission tomography. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00026-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
3
|
Neira S, Guiu-Souto J, Pais P, Rodríguez Martínez de Llano S, Fernández C, Pubul V, Ruibal Á, Pombar M, Gago-Arias A, Pardo-Montero J. Quantification of internal dosimetry in PET patients II: Individualized Monte Carlo-based dosimetry for [18F]fluorocholine PET. Med Phys 2021; 48:5448-5458. [PMID: 34260065 PMCID: PMC9291792 DOI: 10.1002/mp.15090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 06/04/2021] [Accepted: 06/28/2021] [Indexed: 12/03/2022] Open
Abstract
Purpose To obtain individualized internal doses with a Monte Carlo (MC) method in patients undergoing diagnostic [18F]FCH‐PET studies and to compare such doses with the MIRD method calculations. Methods A patient cohort of 17 males were imaged after intravenous administration of a mean [18F]FCH activity of 244.3 MBq. The resulting PET/CT images were processed in order to generate individualized input source and geometry files for dose computation with the MC tool GATE. The resulting dose estimates were studied and compared to the MIRD method with two different computational phantoms. Mass correction of the S‐factors was applied when possible. Potential sources of uncertainty were closely examined: the effect of partial body images, urinary bladder emptying, and biokinetic modeling. Results Large differences in doses between our methodology and the MIRD method were found, generally in the range ±25%, and up to ±120% for some cases. The mass scaling showed improvements, especially for non‐walled and high‐uptake tissues. Simulations of the urinary bladder emptying showed negligible effects on doses to other organs, with the exception of the prostate. Dosimetry based on partial PET/CT images (excluding the legs) resulted in an overestimation of mean doses to bone, skin, and remaining tissues, and minor differences in other organs/tissues. Estimated uncertainties associated with the biokinetics of FCH introduce variations of cumulated activities in the range of ±10% in the high‐uptake organs. Conclusions The MC methodology allows for a higher degree of dosimetry individualization than the MIRD methodology, which in some cases leads to important differences in dose values. Dosimetry of FCH‐PET based on a single partial PET study seems viable due to the particular biokinetics of FCH, even though some correction factors may need to be applied to estimate mean skin/bone doses.
Collapse
Affiliation(s)
- Sara Neira
- Group of Medical Physics and Biomathematics, Instituto de Investigación Sanitaria de Santiago, Santiago de Compostela, Spain
| | - Jacobo Guiu-Souto
- Department of Medical Physics, Centro Oncolóxico de Galicia, A Coruña, Spain
| | - Paulino Pais
- Department of Nuclear Medicine, Centro Oncolóxico de Galicia, A Coruña, Spain
| | | | - Carlos Fernández
- Department of Medical Physics, Centro Oncolóxico de Galicia, A Coruña, Spain
| | - Virginia Pubul
- Department of Nuclear Medicine, Complexo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, Spain
| | - Álvaro Ruibal
- Department of Nuclear Medicine, Complexo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, Spain.,Group of Molecular Imaging and Oncology, Instituto de Investigación Sanitaria de Santiago, Santiago de Compostela, Spain.,Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Universidade de Santiago de Compostela, Santiago de Compostela, Spain.,Fundación Tejerina, Madrid, Spain
| | - Miguel Pombar
- Group of Molecular Imaging and Oncology, Instituto de Investigación Sanitaria de Santiago, Santiago de Compostela, Spain.,Department of Medical Physics, Complexo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, Spain
| | - Araceli Gago-Arias
- Group of Medical Physics and Biomathematics, Instituto de Investigación Sanitaria de Santiago, Santiago de Compostela, Spain.,Department of Medical Physics, Complexo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, Spain.,Institute of Physics, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Juan Pardo-Montero
- Group of Medical Physics and Biomathematics, Instituto de Investigación Sanitaria de Santiago, Santiago de Compostela, Spain.,Department of Medical Physics, Complexo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|
4
|
Alzyoud K, Hogg P, Snaith B, Flintham K, England A. Impact of body part thickness on AP pelvis radiographic image quality and effective dose. Radiography (Lond) 2018; 25:e11-e17. [PMID: 30599841 DOI: 10.1016/j.radi.2018.09.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 09/04/2018] [Accepted: 09/06/2018] [Indexed: 10/28/2022]
Abstract
INTRODUCTION Within medical imaging variations in patient size can generate challenges, especially when selecting appropriate acquisition parameters. This experiment sought to evaluate the impact of increasing body part thickness on image quality (IQ) and effective dose (E) and identify optimum exposure parameters. METHODS An anthropomorphic pelvis phantom was imaged with additional layers (1-15 cm) of animal fat as a proxy for increasing body thickness. Acquisitions used the automatic exposure control (AEC), 100 cm source to image distance (SID) and a range of tube potentials (70-110 kVp). IQ was evaluated physically and perceptually. E was estimated using PCXMC software. RESULTS For all tube potentials, signal to noise ratio (SNR) and contrast to noise ratio (CNR) deceased as body part thickness increased. 70 kVp produced the highest SNR (46.6-22.6); CNR (42.8-17.6). Visual grading showed that the highest IQ scores were achieved using 70 and 75 kVp. As thickness increases, E increased exponentially (r = 0.96; p < 0.001). Correlations were found between visual and physical IQ (SNR r = 0.97, p < 0.001; CNR r = 0.98, p < 0.001). CONCLUSION To achieve an optimal IQ across the range of thicknesses, lower kVp settings were most effective. This is at variance with professional practice as there is a tendency for radiographers to increase kVp as thickness increases. Dose reductions were experienced at higher kVp settings and are a valid method for optimisation when imaging larger patients.
Collapse
Affiliation(s)
- K Alzyoud
- School of Health Sciences, University of Salford, Salford M6 6PU, United Kingdom; Faculty of Allied Health Sciences, Hashemite University, Zarqa, Jordan.
| | - P Hogg
- School of Health Sciences, University of Salford, Salford M6 6PU, United Kingdom.
| | - B Snaith
- The Mid Yorkshire Hospitals NHS Trust, Wakefield WF1 4DG, United Kingdom; University of Bradford, Bradford BD7 1DP, United Kingdom.
| | - K Flintham
- The Mid Yorkshire Hospitals NHS Trust, Wakefield WF1 4DG, United Kingdom.
| | - A England
- School of Health Sciences, University of Salford, Salford M6 6PU, United Kingdom.
| |
Collapse
|
5
|
Belinato W, Silva RM, Perini AP, Neves LP, Santos CJ, Souza DN, Santos WS. Monte Carlo dosimetric evaluation in PET exams for patients with different BMI and heights. Radiat Phys Chem Oxf Engl 1993 2018. [DOI: 10.1016/j.radphyschem.2018.05.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
6
|
Wayson MB, Bolch WE. Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient external anatomy. Phys Med Biol 2018; 63:085007. [PMID: 29546846 DOI: 10.1088/1361-6560/aab72f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Internal radiation dose estimates for diagnostic nuclear medicine procedures are typically calculated for a reference individual. Resultantly, there is uncertainty when determining the organ doses to patients who are not at 50th percentile on either height or weight. This study aims to better personalize internal radiation dose estimates for individual patients by modifying the dose estimates calculated for reference individuals based on easily obtainable morphometric characteristics of the patient. Phantoms of different sitting heights and waist circumferences were constructed based on computational reference phantoms for the newborn, 10 year-old, and adult. Monoenergetic photons and electrons were then simulated separately at 15 energies. Photon and electron specific absorbed fractions (SAFs) were computed for the newly constructed non-reference phantoms and compared to SAFs previously generated for the age-matched reference phantoms. Differences in SAFs were correlated to changes in sitting height and waist circumference to develop scaling factors that could be applied to reference SAFs as morphometry corrections. A further set of arbitrary non-reference phantoms were then constructed and used in validation studies for the SAF scaling factors. Both photon and electron dose scaling methods were found to increase average accuracy when sitting height was used as the scaling parameter (~11%). Photon waist circumference-based scaling factors showed modest increases in average accuracy (~7%) for underweight individuals, but not for overweight individuals. Electron waist circumference-based scaling factors did not show increases in average accuracy. When sitting height and waist circumference scaling factors were combined, modest average gains in accuracy were observed for photons (~6%), but not for electrons. Both photon and electron absorbed doses are more reliably scaled using scaling factors computed in this study. They can be effectively scaled using sitting height alone as patient-specific morphometric parameter.
Collapse
Affiliation(s)
- Michael B Wayson
- Present address: Medical Physics and Radiation Safety, Baylor Scott and White Health, 3500 Gaston Avenue, Dallas, TX 75246, United States of America
| | | |
Collapse
|
7
|
Wayson MB, Bolch WE. Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient internal anatomy. Phys Med Biol 2018; 63:085006. [PMID: 29546844 DOI: 10.1088/1361-6560/aab730] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Various computational tools are currently available that facilitate patient organ dosimetry in diagnostic nuclear medicine, yet they are typically restricted to reporting organ doses to ICRP-defined reference phantoms. The present study, while remaining computational phantom based, provides straightforward tools to adjust reference phantom organ dose for both internal photon and electron sources. A wide variety of monoenergetic specific absorbed fractions were computed using radiation transport simulations for tissue spheres of varying size and separation distance. Scaling methods were then constructed for both photon and electron self-dose and cross-dose, with data validation provided from patient-specific voxel phantom simulations, as well as via comparison to the scaling methodology given in MIRD Pamphlet No. 11. Photon and electron self-dose was found to be dependent on both radiation energy and sphere size. Photon cross-dose was found to be mostly independent of sphere size. Electron cross-dose was found to be dependent on sphere size when the spheres were in close proximity, owing to differences in electron range. The validation studies showed that this dataset was more effective than the MIRD 11 method at predicting patient-specific photon doses for at both high and low energies, but gave similar results at photon energies between 100 keV and 1 MeV. The MIRD 11 method for electron self-dose scaling was accurate for lower energies but began to break down at higher energies. The photon cross-dose scaling methodology developed in this study showed gains in accuracy of up to 9% for actual patient studies, and the electron cross-dose scaling methodology showed gains in accuracy up to 9% as well when only the bremsstrahlung component of the cross-dose was scaled. These dose scaling methods are readily available for incorporation into internal dosimetry software for diagnostic phantom-based organ dosimetry.
Collapse
Affiliation(s)
- Michael B Wayson
- Present address: Medical Physics and Radiation Safety, Baylor Scott and White Health, 3500 Gaston Avenue Dallas, TX 75246, United States of America
| | | |
Collapse
|
8
|
Xie T, Kuster N, Zaidi H. Computational hybrid anthropometric paediatric phantom library for internal radiation dosimetry. Phys Med Biol 2017; 62:3263-3283. [DOI: 10.1088/1361-6560/aa63d0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
9
|
López-Vilanova N, Pavía J, Duch MA, Catafau A, Ros D, Bullich S. Impact of Region-of-Interest Delineation Methods, Reconstruction Algorithms, and Intra- and Inter-Operator Variability on Internal Dosimetry Estimates Using PET. Mol Imaging Biol 2016; 19:305-314. [PMID: 27632424 DOI: 10.1007/s11307-016-1003-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE Human dosimetry studies play a central role in radioligand development for positron emission tomography (PET). Drawing regions of interest (ROIs) on the PET images is used to measure the dose in each organ. In the study aspects related to ROI delineation methods were evaluated for two radioligands of different biodistribution (intestinal vs urinary). PROCEDURES PET images were simulated from a human voxel-based phantom. Several ROI delineation methods were tested: antero-posterior projections (AP), 3D sub-samples of the organs (S), and a 3D volume covering the whole-organ (W). Inter- and intra-operator variability ROI drawing was evaluated by using human data. RESULTS The effective dose estimates using S and W methods were comparable to the true values. AP methods overestimated (49 %) the dose for the radioligand with intestinal biodistribution. Moreover, the AP method showed the highest inter-operator variability: 11 ± 1 %. CONCLUSIONS The sub-sampled organ method showed the best balance between quantitative accuracy and inter- and intra-operator variability.
Collapse
Affiliation(s)
- N López-Vilanova
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona, Spain. .,Institut de Tècniques Energètiques (INTE), Universitat Politècnica de Catalunya (UPC), Barcelona, Spain.
| | - J Pavía
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona, Spain.,Nuclear Medicine Department, Hospital Clínic i Provincial de Barcelona, Barcelona, Spain.,Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - M A Duch
- Institut de Tècniques Energètiques (INTE), Universitat Politècnica de Catalunya (UPC), Barcelona, Spain
| | - A Catafau
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain.,Barcelona Imaging Group (BIG), Barcelona, Spain
| | - D Ros
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona, Spain.,Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain.,Unitat de Biofísica i Bioenginyeria, Universitat de Barcelona, Barcelona, Spain
| | - S Bullich
- Molecular Imaging Centre (CRC-CIM), Barcelona Biomedical Research Park, Barcelona, Spain
| |
Collapse
|
10
|
Quinn B, Dauer Z, Pandit-Taskar N, Schoder H, Dauer LT. Radiation dosimetry of 18F-FDG PET/CT: incorporating exam-specific parameters in dose estimates. BMC Med Imaging 2016; 16:41. [PMID: 27317478 PMCID: PMC4912712 DOI: 10.1186/s12880-016-0143-y] [Citation(s) in RCA: 96] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Accepted: 06/02/2016] [Indexed: 11/26/2022] Open
Abstract
Background Whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) is the standard of care in oncologic diagnosis and staging, and patient radiation dose must be well understood to balance exam benefits with the risk from radiation exposure. Although reference PET/CT patient doses are available, the potential for widely varying total dose prompts evaluation of clinic-specific patient dose. The aims of this study were to use exam-specific information to characterize the radiation dosimetry of PET/CT exams that used two different CT techniques for adult oncology patients and evaluate the practicality of employing an exam-specific approach to dose estimation. Methods Whole body PET/CT scans from two sets of consecutive adult patients were retrospectively reviewed. One set received a PET scan with a standard registration CT and the other a PET scan with a diagnostic quality CT. PET dose was calculated by modifying the standard reference phantoms in OLINDA/EXM 1.1 with patient-specific organ mass. CT dose was calculated using patient-specific data in ImPACT. International Commission on Radiological Protection publication 103 tissue weighting coefficients were used for effective dose. Results One hundred eighty three adult scans were evaluated (95 men, 88 women). The mean patient-specific effective dose from a mean injected 18F-FDG activity of 450 ± 32 MBq was 9.0 ± 1.6 mSv. For all standard PET/CT patients, mean effective mAs was 39 ± 11 mAs, mean CT effective dose was 5.0 ± 1.0 mSv and mean total effective dose was 14 ± 1.3 mSv. For all diagnostic PET/CT patients, mean effective mAs was 120 ± 51 mAs, mean CT effective dose was 15.4 ± 5.0 mSv and mean total effective dose was 24.4 ± 4.3 mSv. The five organs receiving the highest organ equivalent doses in all exams were bladder, heart, brain, liver and lungs. Conclusions Patient-specific parameters optimize the patient dosimetry utilized in the medical justification of whole body PET/CT referrals and optimization of PET and CT acquisition parameters. Incorporating patient-specific data into dose estimates is a worthwhile effort for characterizing patient dose, and the specific dosimetric information assists in the justification of risk and optimization of PET/CT.
Collapse
Affiliation(s)
- Brian Quinn
- Department of Medical Physics, Box 84, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
| | - Zak Dauer
- Department of Medical Physics, Box 84, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Neeta Pandit-Taskar
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, USA
| | - Heiko Schoder
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, USA
| | - Lawrence T Dauer
- Department of Medical Physics, Box 84, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.,Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, USA
| |
Collapse
|
11
|
Liu D, Khong PL, Gao Y, Mahmood U, Quinn B, St Germain J, Xu XG, Dauer LT. Radiation Dosimetry of Whole-Body Dual-Tracer 18F-FDG and 11C-Acetate PET/CT for Hepatocellular Carcinoma. J Nucl Med 2016; 57:907-12. [PMID: 26823568 PMCID: PMC5556938 DOI: 10.2967/jnumed.115.165944] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2015] [Accepted: 01/04/2016] [Indexed: 12/26/2022] Open
Abstract
UNLABELLED Combined whole-body dual-tracer ((18)F-FDG and (11)C-acetate) PET/CT is increasingly used for staging hepatocellular carcinoma, with only limited studies investigating the radiation dosimetry data of these scans. The aim of the study was to characterize the radiation dosimetry of combined whole-body dual-tracer PET/CT protocols. METHODS Consecutive adult patients with hepatocellular carcinoma who underwent whole-body dual-tracer PET/CT scans were retrospectively reviewed with institutional review board approval. OLINDA/EXM 1.1 was used to estimate patient-specific internal dose exposure in each organ. Biokinetic models for (18)F-FDG and (11)C-acetate as provided by ICRP (International Commission on Radiological Protection) publication 106 were used. Standard reference phantoms were modified to more closely represent patient-specific organ mass. With patient-specific parameters, organ equivalent doses from each CT series were estimated using VirtualDose. Dosimetry capabilities for tube current modulation protocols were applied by integrating with the latest anatomic realistic models. Effective dose was calculated using ICRP publication 103 tissue-weighting coefficients for adult male and female, respectively. RESULTS Fourteen scans were evaluated (12 men, 2 women; mean age ± SD, 60 ± 19.48 y). The patient-specific effective dose from (18)F-FDG and (11)C-acetate was 6.08 ± 1.49 and 1.56 ± 0.47 mSv, respectively, for male patients and 6.62 ± 1.38 and 1.79 ± 0.12 mSV, respectively, for female patients. The patient-specific effective dose of the CT component, which comprised 2 noncontrast whole-body scans, to male and female patients was 21.20 ± 8.94 and 14.79 ± 3.35 mSv, respectively. Thus, the total effective doses of the combined whole-body dual-tracer PET/CT studies for male and female patients were 28.84 ± 10.18 and 23.19 ± 4.61 mSv, respectively. CONCLUSION Patient-specific parameters allow for more accurate estimation of organ equivalent doses. Considering the substantial radiation dose incurred, judicious medical justification is required with every whole-body dual-tracer PET/CT referral. Although radiation risks may have less impact for the population with cancer because of their reduced life expectancy, the information is of interest and relevant for both justification, to evaluate risk/benefit, and protocol optimization.
Collapse
Affiliation(s)
- Dan Liu
- Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Pek-Lan Khong
- Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Yiming Gao
- Department of Mechanical, Aerospace, and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, New York
| | - Usman Mahmood
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York; and
| | - Brian Quinn
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York; and
| | - Jean St Germain
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York; and
| | - X George Xu
- Department of Mechanical, Aerospace, and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, New York
| | - Lawrence T Dauer
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York; and Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York
| |
Collapse
|
12
|
Andersson M, Mattsson S. Dose management in conventional nuclear medicine imaging and PET. Clin Transl Imaging 2015. [DOI: 10.1007/s40336-015-0150-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
13
|
Xie T, Bolch WE, Lee C, Zaidi H. Pediatric radiation dosimetry for positron-emitting radionuclides using anthropomorphic phantoms. Med Phys 2014; 40:102502. [PMID: 24089923 DOI: 10.1118/1.4819939] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Positron emission tomography (PET) plays an important role in the diagnosis, staging, treatment, and surveillance of clinically localized diseases. Combined PET/CT imaging exhibits significantly higher sensitivity, specificity, and accuracy than conventional imaging when it comes to detecting malignant tumors in children. However, the radiation dose from positron-emitting radionuclide to the pediatric population is a matter of concern since children are at a particularly high risk when exposed to ionizing radiation. METHODS The authors evaluate the absorbed fractions and specific absorbed fractions (SAFs) of monoenergy photons/electrons as well as S-values of 9 positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124) in 48 source regions for 10 anthropomorphic pediatric hybrid models, including the reference newborn, 1-, 5-, 10-, and 15-yr-old male and female models, using the Monte Carlo N-Particle eXtended general purpose Monte Carlo transport code. RESULTS The self-absorbed SAFs and S-values for most organs were inversely related to the age and body weight, whereas the cross-dose terms presented less correlation with body weight. For most source/target organ pairs, Rb-82 and Y-86 produce the highest self-absorbed and cross-absorbed S-values, respectively, while Cu-64 produces the lowest S-values because of the low-energy and high-frequency of electron emissions. Most of the total self-absorbed S-values are contributed from nonpenetrating particles (electrons and positrons), which have a linear relationship with body weight. The dependence of self-absorbed S-values of the two annihilation photons varies to the reciprocal of 0.76 power of the mass, whereas the self-absorbed S-values of positrons vary according to the reciprocal mass. CONCLUSIONS The produced S-values for common positron-emitting radionuclides can be exploited for the assessment of radiation dose delivered to the pediatric population from various PET radiotracers used in clinical and research settings. The mass scaling method for positron-emitters can be used to derive patient-specific S-values from data of reference phantoms.
Collapse
Affiliation(s)
- Tianwu Xie
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
| | | | | | | |
Collapse
|
14
|
Ikuta I, Sodickson A, Wasser EJ, Warden GI, Gerbaudo VH, Khorasani R. Exposing exposure: enhancing patient safety through automated data mining of nuclear medicine reports for quality assurance and organ dose monitoring. Radiology 2012; 264:406-13. [PMID: 22627599 DOI: 10.1148/radiol.12111823] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
PURPOSE To develop and validate an open-source informatics toolkit capable of creating a radiation exposure data repository from existing nuclear medicine report archives and to demonstrate potential applications of such data for quality assurance and longitudinal patient-specific radiation dose monitoring. MATERIALS AND METHODS This study was institutional review board approved and HIPAA compliant. Informed consent was waived. An open-source toolkit designed to automate the extraction of data on radiopharmaceuticals and administered activities from nuclear medicine reports was developed. After iterative code training, manual validation was performed on 2359 nuclear medicine reports randomly selected from September 17, 1985, to February 28, 2011. Recall (sensitivity) and precision (positive predictive value) were calculated with 95% binomial confidence intervals. From the resultant institutional data repository, examples of usage in quality assurance efforts and patient-specific longitudinal radiation dose monitoring obtained by calculating organ doses from the administered activity and radiopharmaceutical of each examination were provided. RESULTS Validation statistics yielded a combined recall of 97.6% ± 0.7 (95% confidence interval) and precision of 98.7% ± 0.5. Histograms of administered activity for fluorine 18 fluorodeoxyglucose and iodine 131 sodium iodide were generated. An organ dose heatmap which displays a sample patient's dose accumulation from multiple nuclear medicine examinations was created. CONCLUSION Large-scale repositories of radiation exposure data can be extracted from institutional nuclear medicine report archives with high recall and precision. Such repositories enable new approaches in radiation exposure patient safety initiatives and patient-specific radiation dose monitoring.
Collapse
Affiliation(s)
- Ichiro Ikuta
- Department of Radiology, Harvard Medical School, Boston, MA 02115, USA
| | | | | | | | | | | |
Collapse
|
15
|
Ding A, Mille MM, Liu T, Caracappa PF, Xu XG. Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose. Phys Med Biol 2012; 57:2441-59. [PMID: 22481470 DOI: 10.1088/0031-9155/57/9/2441] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newly developed phantoms representing overweight and obese patients. These phantoms were derived from the previously developed RPI-adult male and female computational phantoms. The result was a set of ten phantoms (five males, five females) with body mass indexes ranging from 23.5 (normal body weight) to 46.4 kg m(-2) (morbidly obese). The phantoms were modeled using triangular mesh geometry and include specified amounts of the subcutaneous adipose tissue and visceral adipose tissue. The mesh-based phantoms were then voxelized and defined in the Monte Carlo N-Particle Extended code to calculate organ doses from CT imaging. Chest-abdomen-pelvis scanning protocols for a GE LightSpeed 16 scanner operating at 120 and 140 kVp were considered. It was found that for the same scanner operating parameters, radiation doses to organs deep in the abdomen (e.g., colon) can be up to 59% smaller for obese individuals compared to those of normal body weight. This effect was found to be less significant for shallow organs. On the other hand, increasing the tube potential from 120 to 140 kVp for the same obese individual resulted in increased organ doses by as much as 56% for organs within the scan field (e.g., stomach) and 62% for those out of the scan field (e.g., thyroid), respectively. As higher tube currents are often used for larger patients to maintain image quality, it was of interest to quantify the associated effective dose. It was found from this study that when the mAs was doubled for the obese level-I, obese level-II and morbidly-obese phantoms, the effective dose relative to that of the normal weight phantom increased by 57%, 42% and 23%, respectively. This set of new obese phantoms can be used in the future to study the optimization of image quality and radiation dose for patients of different weight classifications. Our ultimate goal is to compile all the data derived from these phantoms into a comprehensive dosimetry database defined in the VirtualDose software.
Collapse
Affiliation(s)
- Aiping Ding
- Nuclear Engineering and Engineering Physics Program, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | | | | | | | | |
Collapse
|
16
|
Dosimetric evaluation of nanotargeted (188)Re-liposome with the MIRDOSE3 and OLINDA/EXM programs. Ann Nucl Med 2012; 26:419-25. [PMID: 22450826 DOI: 10.1007/s12149-012-0593-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2011] [Accepted: 03/07/2012] [Indexed: 12/12/2022]
Abstract
OBJECTIVE The OLINDA/EXM computer code was created as a replacement for the widely used MIRDOSE3 code for radiation dosimetry in nuclear medicine. A dosimetric analysis with these codes was performed to evaluate nanoliposomes as carriers of radionuclides ((188)Re-liposomes) in colon carcinoma-bearing mice. METHODS Pharmacokinetic data for (188)Re-N, N-bis (2-mercaptoethyl)-N',N'-diethylethylenediamine ((188)Re-BMEDA) and (188)Re-liposome were obtained for estimation of absorbed doses in normal organs. Radiation dose estimates for normal tissues were calculated using the MIRDOSE3 and OLINDA/EXM programs for a colon carcinoma solid tumor mouse model. RESULTS Mean absorbed doses derived from(188)Re-BMEDA and (188)Re-liposome in normal tissues were generally similar as calculated by MIRDOSE3 and OLINDA/EXM programs. One notable exception to this was red marrow, wherein MIRDOSE3 resulted in higher absorbed doses than OLINDA/EXM (1.53- and 1.60-fold for (188)Re-BMEDA and (188)Re-liposome, respectively). CONCLUSIONS MIRDOSE3 and OLINDA have very similar residence times and organ doses. Bone marrow doses were estimated by designating cortical bone rather than bone marrow as a source organ. The bone marrow doses calculated by MIRDOSE3 are higher than those by OLINDA. If the bone marrow is designated as a source organ, the doses estimated by MIRDOSE3 and OLINDA programs will be very similar.
Collapse
|
17
|
Stabin MG, Emmons MA, Segars WP, Fernald MJ. Realistic reference adult and paediatric phantom series for internal and external dosimetry. RADIATION PROTECTION DOSIMETRY 2012; 149:56-59. [PMID: 22128359 PMCID: PMC3303490 DOI: 10.1093/rpd/ncr383] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2011] [Revised: 08/27/2011] [Accepted: 08/29/2011] [Indexed: 05/31/2023]
Abstract
A new generation of realistic, image-based anthropomorphic phantoms has been developed based on the reference masses and organ definitions given in the International Commission on Radiological Protection Publication 89. Specific absorbed fractions for internal radiation sources have been calculated for photon and electron sources for many body organs. Values are similar to those from the previous generation of 'stylized' (mathematical equation-based) models, but some differences are seen, particularly at low particle or photon energies, due to the more realistic organ geometries, with organs generally being closer together, and with some touching and overlapping. Extension of this work, to use these phantoms in Monte Carlo radiation transport simulation codes with external radiation sources, is an important area of investigation that should be undertaken.
Collapse
Affiliation(s)
- M G Stabin
- Vanderbilt University, Nashville, TN, USA.
| | | | | | | |
Collapse
|
18
|
Wierts R, de Pont CD, Brans B, Mottaghy FM, Kemerink GJ. Dosimetry in molecular nuclear therapy. Methods 2011; 55:196-202. [DOI: 10.1016/j.ymeth.2011.09.016] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2011] [Revised: 09/11/2011] [Accepted: 09/13/2011] [Indexed: 01/06/2023] Open
|
19
|
Cassola VF, Milian FM, Kramer R, de Oliveira Lira CAB, Khoury HJ. Standing adult human phantoms based on 10th, 50th and 90th mass and height percentiles of male and female Caucasian populations. Phys Med Biol 2011; 56:3749-72. [PMID: 21628776 DOI: 10.1088/0031-9155/56/13/002] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Computational anthropomorphic human phantoms are useful tools developed for the calculation of absorbed or equivalent dose to radiosensitive organs and tissues of the human body. The problem is, however, that, strictly speaking, the results can be applied only to a person who has the same anatomy as the phantom, while for a person with different body mass and/or standing height the data could be wrong. In order to improve this situation for many areas in radiological protection, this study developed 18 anthropometric standing adult human phantoms, nine models per gender, as a function of the 10th, 50th and 90th mass and height percentiles of Caucasian populations. The anthropometric target parameters for body mass, standing height and other body measures were extracted from PeopleSize, a well-known software package used in the area of ergonomics. The phantoms were developed based on the assumption of a constant body-mass index for a given mass percentile and for different heights. For a given height, increase or decrease of body mass was considered to reflect mainly the change of subcutaneous adipose tissue mass, i.e. that organ masses were not changed. Organ mass scaling as a function of height was based on information extracted from autopsy data. The methods used here were compared with those used in other studies, anatomically as well as dosimetrically. For external exposure, the results show that equivalent dose decreases with increasing body mass for organs and tissues located below the subcutaneous adipose tissue layer, such as liver, colon, stomach, etc, while for organs located at the surface, such as breasts, testes and skin, the equivalent dose increases or remains constant with increasing body mass due to weak attenuation and more scatter radiation caused by the increasing adipose tissue mass. Changes of standing height have little influence on the equivalent dose to organs and tissues from external exposure. Specific absorbed fractions (SAFs) have also been calculated with the 18 anthropometric phantoms. The results show that SAFs decrease with increasing height and increase with increasing body mass. The calculated data suggest that changes of the body mass may have a significant effect on equivalent doses, primarily for external exposure to organs and tissue located below the adipose tissue layer, while for superficial organs, for changes of height and for internal exposures the effects on equivalent dose are small to moderate.
Collapse
Affiliation(s)
- V F Cassola
- Department of Nuclear Energy, Federal University of Pernambuco, Avenida Professor Luiz Freire, 1000, CEP 50740-540, Recife, PE, Brazil
| | | | | | | | | |
Collapse
|
20
|
Abstract
This review provides a practical overview of the excess cancer risks related to radiation from medical imaging. Primary care physicians should have a basic understanding of these risks. Because of recent attention to this issue, patients are more likely to express concerns over radiation risk. In addition, physicians can play a role in reducing radiation risk to their patients by considering these risks when making imaging referrals. This review provides a brief overview of the evidence pertaining to low-level radiation and excess cancer risks and addresses the radiation doses and risks from common medical imaging studies. Specific subsets of patients may be at greater risk from radiation exposure, and radiation risk should be considered carefully in these patients. Recent technical innovations have contributed to lowering the radiation dose from computed tomography, and the referring physician should be aware of these innovations in making imaging referrals.
Collapse
Affiliation(s)
- Eugene C Lin
- Department of Radiology, Virginia Mason Medical Center, 1100 Ninth Ave, Seattle, WA 98111, USA.
| |
Collapse
|