Liu C, Liu H, Li Y, Xiao Z, Wang Y, Guo H, Luo J. Establishing a 4D-CT lung function related volumetric dose model to reduce radiation pneumonia. Sci Rep 2024; 14:12589. [PMID: 38824238 PMCID: PMC11144207 DOI: 10.1038/s41598-024-63251-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Accepted: 05/27/2024] [Indexed: 06/03/2024] Open
Abstract
In order to study how to use pulmonary functional imaging obtained through 4D-CT fusion for radiotherapy planning, and transform traditional dose volume parameters into functional dose volume parameters, a functional dose volume parameter model that may reduce level 2 and above radiation pneumonia was obtained. 41 pulmonary tumor patients who underwent 4D-CT in our department from 2020 to 2023 were included. MIM Software (MIM 7.0.7; MIM Software Inc., Cleveland, OH, USA) was used to register adjacent phase CT images in the 4D-CT series. The three-dimensional displacement vector of CT pixels was obtained when changing from one respiratory state to another respiratory state, and this three-dimensional vector was quantitatively analyzed. Thus, a color schematic diagram reflecting the degree of changes in lung CT pixels during the breathing process, namely the distribution of ventilation function strength, is obtained. Finally, this diagram is fused with the localization CT image. Select areas with Jacobi > 1.2 as high lung function areas and outline them as fLung. Import the patient's DVH image again, fuse the lung ventilation image with the localization CT image, and obtain the volume of fLung different doses (V60, V55, V50, V45, V40, V35, V30, V25, V20, V15, V10, V5). Analyze the functional dose volume parameters related to the risk of level 2 and above radiation pneumonia using R language and create a predictive model. By using stepwise regression and optimal subset method to screen for independent variables V35, V30, V25, V20, V15, and V10, the prediction formula was obtained as follows: Risk = 0.23656-0.13784 * V35 + 0.37445 * V30-0.38317 * V25 + 0.21341 * V20-0.10209 * V15 + 0.03815 * V10. These six independent variables were analyzed using a column chart, and a calibration curve was drawn using the calibrate function. It was found that the Bias corrected line and the Apparent line were very close to the Ideal line, The consistency between the predicted value and the actual value is very good. By using the ROC function to plot the ROC curve and calculating the area under the curve: 0.8475, 95% CI 0.7237-0.9713, it can also be determined that the accuracy of the model is very high. In addition, we also used Lasso method and random forest method to filter out independent variables with different results, but the calibration curve drawn by the calibration function confirmed poor prediction performance. The function dose volume parameters V35, V30, V25, V20, V15, and V10 obtained through 4D-CT are key factors affecting radiation pneumonia. Establishing a predictive model can provide more accurate lung restriction basis for clinical radiotherapy planning.
Collapse
Affiliation(s)
- Chunmei Liu
- Department of Radiation Oncology, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang, 050000, Hebei, China
| | - Huizhi Liu
- Department of Radiation Oncology, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang, 050000, Hebei, China
| | - Yange Li
- Department of Radiation Oncology, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang, 050000, Hebei, China
| | - Zhiqing Xiao
- Department of Radiation Oncology, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang, 050000, Hebei, China
| | - Yanqiang Wang
- Department of Radiation Oncology, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang, 050000, Hebei, China
| | - Han Guo
- Department of Radiation Oncology, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang, 050000, Hebei, China
| | - Jianmin Luo
- Department of Hematology, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang, 050000, Hebei, China.
| |
Collapse
|
2
|
Zhou PX, Zhang SX. Functional lung imaging in thoracic tumor radiotherapy: Application and progress. Front Oncol 2022; 12:908345. [PMID: 36212454 PMCID: PMC9544588 DOI: 10.3389/fonc.2022.908345] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 08/17/2022] [Indexed: 12/12/2022] Open
Abstract
Radiotherapy plays an irreplaceable and unique role in treating thoracic tumors, but the occurrence of radiation-induced lung injury has limited the increase in tumor target doses and has influenced patients’ quality of life. However, the introduction of functional lung imaging has been incorporating functional lungs into radiotherapy planning. The design of the functional lung protection plan, while meeting the target dose requirements and dose limitations of the organs at risk (OARs), minimizes the radiation dose to the functional lung, thus reducing the occurrence of radiation-induced lung injury. In this manuscript, we mainly reviewed the lung ventilation or/and perfusion functional imaging modalities, application, and progress, as well as the results based on the functional lung protection planning in thoracic tumors. In addition, we also discussed the problems that should be explored and further studied in the practical application based on functional lung radiotherapy planning.
Collapse
Affiliation(s)
- Pi-Xiao Zhou
- Radiotherapy Center, Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou, China
- Department of Oncology, The First People's Hospital of Changde City, Changde, China
| | - Shu-Xu Zhang
- Radiotherapy Center, Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou, China
- *Correspondence: Shu-Xu Zhang,
| |
Collapse
|
3
|
Zhou PX, Wang RH, Yu H, Zhang Y, Zhang GQ, Zhang SX. Different functional lung-sparing strategies and radiotherapy techniques for patients with esophageal cancer. Front Oncol 2022; 12:898141. [PMID: 36091164 PMCID: PMC9459335 DOI: 10.3389/fonc.2022.898141] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 07/29/2022] [Indexed: 12/24/2022] Open
Abstract
BackgroundIntegration of 4D-CT ventilation function images into esophageal cancer radiation treatment planning aimed to assess dosimetric differences between different functional lung (FL) protection strategies and radiotherapy techniques.MethodsA total of 15 patients with esophageal cancer who had 4D-CT scans were included. Lung ventilation function images based on Jacobian values were obtained by deformation image registration and ventilation imaging algorithm. Several different plans were designed for each patient: clinical treatment planning (non-sparing planning), the same beam distribution to FL-sparing planning, three fixed-beams FL-sparing intensity-modulated radiation therapy (IMRT) planning (5F-IMRT, 7F-IMRT, 9F-IMRT), and two FL-sparing volumetric modulated arc therapy (VMAT) planning [1F-VMAT (1-Arc), 2F-VMAT (2-Arc)]. The dosimetric parameters of the planning target volume (PTV) and organs at risk (OARs) were compared and focused on dosimetric differences in FL.ResultsThe FL-sparing planning compared with the non-sparing planning significantly decreased the FL-Dmean, V5-30 and Lungs-Dmean, V10-30 (Vx: volume of receiving ≥X Gy), although it slightly compromised PTV conformability and increased Heart-V40 (P< 0.05). The 5F-IMRT had the lowest PTV-conformability index (CI) but had a lower Lungs and Heart irradiation dose compared with those of the 7F-IMRT and 9F-IMRT (P< 0.05). The 2F-VMAT had higher PTV-homogeneity index (HI) and reduced irradiation dose to FL, Lungs, and Heart compared to those of the 1F-VMAT planning (P< 0.05). The 2F-VMAT had higher PTV conformability and homogeneity and decreased FL-Dmean, V5-20 and Lungs-Dmean, V5-10 but correspondingly increased spinal cord-Dmean compared with those of the 5F-IMRT planning (P< 0.05).ConclusionIn this study, 4D-CT ventilation function image-based FL-sparing planning for esophageal cancer can effectively reduce the dose of the FL. The 2F-VMAT planning is better than the 5F-IMRT planning in reducing the dose of FL.
Collapse
|
4
|
Zhou PX, Zhang Y, Zhang QB, Zhang GQ, Yu H, Zhang SX. Functional Liver Imaging in Radiotherapy for Liver Cancer: A Systematic Review and Meta-Analysis. Front Oncol 2022; 12:898435. [PMID: 35785217 PMCID: PMC9247161 DOI: 10.3389/fonc.2022.898435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 05/19/2022] [Indexed: 11/13/2022] Open
Abstract
Backgrounds Functional liver imaging can identify functional liver distribution heterogeneity and integrate it into radiotherapy planning. The feasibility and clinical benefit of functional liver-sparing radiotherapy planning are currently unknown. Methods A comprehensive search of several primary databases was performed to identify studies that met the inclusion criteria. The primary objective of this study was to evaluate the dosimetric and clinical benefits of functional liver-sparing planning radiotherapy. Secondary objectives were to assess the ability of functional imaging to predict the risk of radiation-induced liver toxicity (RILT), and the dose-response relationship after radiotherapy. Results A total of 20 publications were enrolled in descriptive tables and meta-analysis. The meta-analysis found that mean functional liver dose (f-MLD) was reduced by 1.0 Gy [95%CI: (-0.13, 2.13)], standard mean differences (SMD) of functional liver volume receiving ≥20 Gy (fV20) decreased by 0.25 [95%CI: (-0.14, 0.65)] when planning was optimized to sparing functional liver (P >0.05). Seven clinical prospective studies reported functional liver-sparing planning-guided radiotherapy leads to a low incidence of RILD, and the single rate meta-analysis showed that the RILD (defined as CTP score increase ≥2) incidence was 0.04 [95%CI: (0.00, 0.11), P <0.05]. Four studies showed that functional liver imaging had a higher value to predict RILT than conventional anatomical CT. Four studies established dose-response relationships in functional liver imaging after radiotherapy. Conclusion Although functional imaging modalities and definitions are heterogeneous between studies, but incorporation into radiotherapy procedures for liver cancer patients may provide clinical benefits. Further validation in randomized clinical trials will be required in the future.
Collapse
Affiliation(s)
| | | | | | | | | | - Shu-Xu Zhang
- Radiotherapy Center, Affiliated Cancer Hospital and Institute of Guangzhou Medical University, Guangzhou, China
| |
Collapse
|
5
|
Sørensen M, Fode MM, Petersen JB, Holt MI, Høyer M. Effect of stereotactic body radiotherapy on regional metabolic liver function investigated in patients by dynamic [ 18F]FDGal PET/CT. Radiat Oncol 2021; 16:192. [PMID: 34598730 PMCID: PMC8485519 DOI: 10.1186/s13014-021-01909-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 09/09/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose Stereotactic body radiotherapy (SBRT) is increasingly used for treatment of liver tumors but the effect on metabolic liver function in surrounding tissue is largely unknown. Using 2-deoxy-2-[18F]fluoro-d-galactose ([18F]FDGal) positron emission tomography (PET)/computed tomography (CT), we aimed to determine a dose–response relationship between radiation dose and metabolic liver function as well as recovery. Procedures. One male subject with intrahepatic cholangiocarcinoma and five subjects (1 female, 4 male) with liver metastases from colorectal cancer (mCRC) underwent [18F]FDGal PET/CT before SBRT and after 1 and 3 months. The dose response was calculated using the data after 1 month and the relative recovery was evaluated after 3 months. All patients had normal liver function at time of inclusion. Results A linear dose–response relationship for the individual liver voxel dose was seen until approximately 30 Gy. By fitting a polynomial curve to data, a mean TD50 of 18 Gy was determined with a 95% CI from 12 to 26 Gy. After 3 months, a substantial recovery was observed except in tissue receiving more than 25 Gy. Conclusions [18F]FDGal PET/CT makes it possible to determine a dose–response relationship between radiation dose and metabolic liver function, here with a TD50 of 18 Gy (95% CI 12–26 Gy). Moreover, the method makes it possible to estimate metabolic recovery in liver tissue.
Collapse
Affiliation(s)
- Michael Sørensen
- Departement of Nuclear Medicine & PET, Aarhus University Hospital, Aarhus N, Denmark. .,Departement of Hepatology & Gastroenterology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, C116, 8200, Aarhus N, Denmark. .,Department of Internal Medicine, Viborg Regional Hospital, Viborg, Denmark.
| | - Mette Marie Fode
- Departement of Oncology, Aarhus University Hospital, Aarhus N, Denmark
| | | | - Marianne Ingerslev Holt
- Departement of Oncology, Aarhus University Hospital, Aarhus N, Denmark.,Department of Genetics, Vejle Hospital, Vejle, Denmark
| | - Morten Høyer
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus N, Denmark
| |
Collapse
|
6
|
Palma G, Monti S, Conson M, Pacelli R, Cella L. Normal tissue complication probability (NTCP) models for modern radiation therapy. Semin Oncol 2019; 46:210-218. [PMID: 31506196 DOI: 10.1053/j.seminoncol.2019.07.006] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 07/31/2019] [Indexed: 02/07/2023]
Abstract
Mathematical models of normal tissue complication probability (NTCP) able to robustly predict radiation-induced morbidities (RIM) play an essential role in the identification of a personalized optimal plan, and represent the key to maximizing the benefits of technological advances in radiation therapy (RT). Most modern RT techniques pose, however, new challenges in estimating the risk of RIM. The aim of this report is to schematically review NTCP models in the framework of advanced radiation therapy techniques. Issues relevant to hypofractionated stereotactic body RT and ion beam therapy are critically reviewed. Reirradiation scenarios for new or recurrent malignances and NTCP are also illustrated. A new phenomenological approach to predict RIM is suggested.
Collapse
Affiliation(s)
- Giuseppe Palma
- National Research Council, Institute of Biostructures and Bioimaging, Napoli, Italy
| | - Serena Monti
- National Research Council, Institute of Biostructures and Bioimaging, Napoli, Italy
| | - Manuel Conson
- Department of Advanced Biomedical Sciences, Federico II University School of Medicine, Naples, Italy
| | - Roberto Pacelli
- Department of Advanced Biomedical Sciences, Federico II University School of Medicine, Naples, Italy
| | - Laura Cella
- National Research Council, Institute of Biostructures and Bioimaging, Napoli, Italy.
| |
Collapse
|
7
|
Zhu T, Das S, Wong TZ. Integration of PET/MR Hybrid Imaging into Radiation Therapy Treatment. Magn Reson Imaging Clin N Am 2017; 25:377-430. [PMID: 28390536 DOI: 10.1016/j.mric.2017.01.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Hybrid PET/MR imaging is in early development for treatment planning. This article briefly reviews research and clinical applications of PET/MR imaging in radiation oncology. With improvements in workflow, more specific tracers, and fast and robust acquisition protocols, PET/MR imaging will play an increasingly important role in better target delineation for treatment planning and have clear advantages in the evaluation of tumor response and in a better understanding of tumor heterogeneity. With advances in treatment delivery and the potential of integrating PET/MR imaging with research on radiomics for radiation oncology, quantitative and physiologic information could lead to more precise and personalized RT.
Collapse
Affiliation(s)
- Tong Zhu
- Department of Radiation Oncology, University of North Carolina at Chapel Hill, 101 Manning Drive, Chapel Hill, NC 27599, USA
| | - Shiva Das
- Department of Radiation Oncology, University of North Carolina at Chapel Hill, 101 Manning Drive, Chapel Hill, NC 27599, USA
| | - Terence Z Wong
- Department of Radiology, University of North Carolina at Chapel Hill, 101 Manning Drive, Chapel Hill, NC 27599, USA.
| |
Collapse
|
8
|
Fode MM, Bak-Fredslund K, Petersen JB, Worm E, Sørensen M, Høyer M. A phase I study on stereotactic body radiotherapy of liver metastases based on functional treatment planning using positron emission tomography with 2-[ 18F]fluoro-2-deoxy-d-galactose. Acta Oncol 2017; 56:1614-1620. [PMID: 28849688 DOI: 10.1080/0284186x.2017.1366051] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND AND PURPOSE The galactose analog 2-[18F]fluoro-2-deoxy-d-galactose (FDGal) is used for quantification of regional hepatic metabolic capacity by functional positron emission tomography computerized tomography (PET/CT). In the present study, FDGal PET/CT was used for functional treatment planning (FTP) of stereotactic body radiotherapy (SBRT) of liver metastases with the aim of minimizing radiation dose to the best functioning liver tissue. MATERIAL AND METHODS Fourteen patients referred for SBRT had FDGal PET/CT performed before and one month after the treatment. The planning CT and the FDGal PET/CT images were deformable co-registered. RESULTS A reduction in the mean dose of approximately 2 Gy to the best functioning sub-volumes was obtained. One patient developed grade 2 acute morbidity and no patients experienced grade 3 or higher acute morbidities. The regional hepatic metabolic function post-treatment was linearly correlated to the regional radiation dose and for each 10-Gy increase in dose (γ10Gy), the metabolic function was reduced by 12%. A 50% reduction was seen at 22.9 Gy in 3 fractions (CI 95%: 16.7-30.4 Gy). CONCLUSION The clinical study demonstrates the feasibility for FTP in patients with liver metastases and it was possible to minimize the radiation dose to the best functioning liver tissue.
Collapse
Affiliation(s)
- Mette Marie Fode
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - Kirstine Bak-Fredslund
- Department of Nuclear Medicine & PET Centre, Aarhus University Hospital, Aarhus, Denmark
- Department of Hepatology & Gastroenterology, Aarhus University Hospital, Aarhus, Denmark
| | | | - Esben Worm
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | - Michael Sørensen
- Department of Nuclear Medicine & PET Centre, Aarhus University Hospital, Aarhus, Denmark
- Department of Hepatology & Gastroenterology, Aarhus University Hospital, Aarhus, Denmark
| | - Morten Høyer
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
9
|
Fode MM, Petersen JB, Sørensen M, Holt MI, Keiding S, Høyer M. 2-[18F]fluoro-2-deoxy-d-galactose positron emission tomography guided functional treatment planning of stereotactic body radiotherapy of liver tumours. Phys Imaging Radiat Oncol 2017. [DOI: 10.1016/j.phro.2017.02.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
10
|
Muren LP, Jornet N, Georg D, Garcia R, Thwaites DI. Improving radiotherapy through medical physics developments. Radiother Oncol 2015; 117:403-6. [DOI: 10.1016/j.radonc.2015.11.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Accepted: 11/19/2015] [Indexed: 01/21/2023]
|
11
|
Abstract
The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT.
Collapse
Affiliation(s)
- Maria A Schmidt
- Cancer Research UK Cancer Imaging Centre, Royal Marsden Hospital and the Institute of Cancer Research, Downs Road, Sutton, Surrey, SM2 5PT, UK
| | | |
Collapse
|
12
|
Jeraj R, Bradshaw T, Simončič U. Molecular Imaging to Plan Radiotherapy and Evaluate Its Efficacy. J Nucl Med 2015; 56:1752-65. [PMID: 26383148 DOI: 10.2967/jnumed.114.141424] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Accepted: 09/08/2015] [Indexed: 12/25/2022] Open
Abstract
Molecular imaging plays a central role in the management of radiation oncology patients. Specific uses of imaging, particularly to plan radiotherapy and assess its efficacy, require an additional level of reproducibility and image quality beyond what is required for diagnostic imaging. Specific requirements include proper patient preparation, adequate technologist training, careful imaging protocol design, reliable scanner technology, reproducible software algorithms, and reliable data analysis methods. As uncertainty in target definition is arguably the greatest challenge facing radiation oncology, the greatest impact that molecular imaging can have may be in the reduction of interobserver variability in target volume delineation and in providing greater conformity between target volume boundaries and true tumor boundaries. Several automatic and semiautomatic contouring methods based on molecular imaging are available but still need sufficient validation to be widely adopted. Biologically conformal radiotherapy (dose painting) based on molecular imaging-assessed tumor heterogeneity is being investigated, but many challenges remain to fully exploring its potential. Molecular imaging also plays increasingly important roles in both early (during treatment) and late (after treatment) response assessment as both a predictive and a prognostic tool. Because of potentially confounding effects of radiation-induced inflammation, treatment response assessment requires careful interpretation. Although molecular imaging is already strongly embedded in radiotherapy, the path to widespread and all-inclusive use is still long. The lack of solid clinical evidence is the main impediment to broader use. Recommendations for practicing physicians are still rather scarce. (18)F-FDG PET/CT remains the main molecular imaging modality in radiation oncology applications. Although other molecular imaging options (e.g., proliferation imaging) are becoming more common, their widespread use is limited by lack of tracer availability and inadequate reimbursement models. With the increasing presence of molecular imaging in radiation oncology, special emphasis should be placed on adequate training of radiation oncology personnel to understand the potential, and particularly the limitations, of quantitative molecular imaging applications. Similarly, radiologists and nuclear medicine specialists should be sensitized to the special need of the radiation oncologist in terms of quantification and reproducibility. Furthermore, strong collaboration between radiation oncology, nuclear medicine/radiology, and medical physics teams is necessary, as optimal and safe use of molecular imaging can be ensured only within appropriate interdisciplinary teams.
Collapse
Affiliation(s)
- Robert Jeraj
- School of Medicine and Public Health, University of Wisconsin, Madison, Wisconsin; and Faculty of Mathematics and Physics, University of Ljubljana, Ljubljana, Slovenia
| | - Tyler Bradshaw
- School of Medicine and Public Health, University of Wisconsin, Madison, Wisconsin; and
| | - Urban Simončič
- Faculty of Mathematics and Physics, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
13
|
Clark HD, Moiseenko VV, Rackley TP, Thomas SD, Wu JS, Reinsberg SA. Development of a method for functional aspect identification in parotid using dynamic contrast-enhanced magnetic resonance imaging and concurrent stimulation. Acta Oncol 2015; 54:1686-90. [PMID: 26252349 DOI: 10.3109/0284186x.2015.1067718] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Haley D Clark
- a Department of Physics and Astronomy , University of British Columbia , Vancouver, British Columbia , Canada
- b Department of Medical Physics , British Columbia Cancer Agency , Vancouver, British Columbia , Canada
| | - Vitali V Moiseenko
- c Department of Medicine and Applied Sciences , University of California , San Diego, La Jolla, California , USA
| | - Thomas P Rackley
- d Department of Radiation Oncology , British Columbia Cancer Agency , Vancouver, British Columbia , Canada
| | - Steven D Thomas
- b Department of Medical Physics , British Columbia Cancer Agency , Vancouver, British Columbia , Canada
| | - Jonn S Wu
- d Department of Radiation Oncology , British Columbia Cancer Agency , Vancouver, British Columbia , Canada
| | - Stefan A Reinsberg
- a Department of Physics and Astronomy , University of British Columbia , Vancouver, British Columbia , Canada
| |
Collapse
|
14
|
Farr KP, Møller DS, Khalil AA, Kramer S, Morsing A, Grau C. Loss of lung function after chemo-radiotherapy for NSCLC measured by perfusion SPECT/CT: Correlation with radiation dose and clinical morbidity. Acta Oncol 2015. [PMID: 26203930 DOI: 10.3109/0284186x.2015.1061695] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND The purpose of the study was to assess dose and time dependence of radiotherapy (RT)-induced changes in regional lung function measured with single photon emission computed tomography (SPECT) of the lung and relate these changes to the symptomatic endpoint of radiation pneumonitis (RP) in patients treated for non-small cell lung cancer (NSCLC). MATERIAL AND METHODS NSCLC patients scheduled to receive curative RT of minimum 60 Gy were included prospectively in the study. Lung perfusion SPECT/CT was performed before and three months after RT. Reconstructed SPECT/CT data were registered to treatment planning CT. Dose to the lung was segmented into regions corresponding to 0-5, 6-20, 21-40, 41-60 and > 60 Gy. Changes (%) in regional lung perfusion before and after RT were correlated with regional dose and symptomatic RP (CTC grade 2-5) outcome. RESULTS A total of 58 patients were included, of which 45 had three-month follow-up SPECT/CT scans. Analysis showed a statistically significant dose-dependent reduction in regional perfusion at three-month follow-up. The largest population composite perfusion loss was in 41-60 Gy (42.2%) and > 60 Gy (41.7%) dose bins. Lung regions receiving low dose of 0-5 Gy and 6-20 Gy had corresponding perfusion increase (-7.2% and -6.1%, respectively). Regional perfusion reduction was different in patients with and without RP with the largest difference in 21-40 Gy bin (p = 0.02), while for other bins the difference did not reach statistical significance. The risk of symptomatic RP was higher for the patients with perfusion reduction after RT (p = 0.02), with the relative risk estimate of 3.6 (95% CI 1.1-12). CONCLUSION Perfusion lung function changes in a dose-dependent manner after RT. The severity of radiation-induced lung symptoms is significantly correlated with SPECT perfusion changes. Perfusion reduction early after RT is associated with a high risk of later development of symptomatic RP.
Collapse
Affiliation(s)
- Katherina P Farr
- a Department of Oncology , Aarhus University Hospital , Aarhus C , Denmark
| | - Ditte S Møller
- b Department of Medical Physics , Aarhus University Hospital , Aarhus C , Denmark
| | - Azza A Khalil
- a Department of Oncology , Aarhus University Hospital , Aarhus C , Denmark
| | - Stine Kramer
- c Department of Nuclear Medicine and PET Centre , Aarhus University Hospital , Aarhus C , Denmark
| | - Anni Morsing
- c Department of Nuclear Medicine and PET Centre , Aarhus University Hospital , Aarhus C , Denmark
| | - Cai Grau
- a Department of Oncology , Aarhus University Hospital , Aarhus C , Denmark
| |
Collapse
|
15
|
Tahir BA, Swift AJ, Marshall H, Parra-Robles J, Hatton MQ, Hartley R, Kay R, Brightling CE, Vos W, Wild JM, Ireland RH. A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI. Phys Med Biol 2014; 59:7267-77. [PMID: 25383657 DOI: 10.1088/0031-9155/59/23/7267] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Hyperpolarized gas magnetic resonance imaging (MRI) generates highly detailed maps of lung ventilation and physiological function while CT provides corresponding anatomical and structural information. Fusion of such complementary images enables quantitative analysis of pulmonary structure-function. However, direct image registration of hyperpolarized gas MRI to CT is problematic, particularly in lungs whose boundaries are difficult to delineate due to ventilation heterogeneity. This study presents a novel indirect method of registering hyperpolarized gas MRI to CT utilizing (1)H-structural MR images that are acquired in the same breath-hold as the gas MRI. The feasibility of using this technique for regional quantification of ventilation of specific pulmonary structures is demonstrated for the lobes.The direct and indirect methods of hyperpolarized gas MRI to CT image registration were compared using lung images from 15 asthma patients. Both affine and diffeomorphic image transformations were implemented. Registration accuracy was evaluated using the target registration error (TRE) of anatomical landmarks identified on (1)H MRI and CT. The Wilcoxon signed-rank test was used to test statistical significance.For the affine transformation, the indirect method of image registration was significantly more accurate than the direct method (TRE = 14.7 ± 3.2 versus 19.6 ± 12.7 mm, p = 0.036). Using a deformable transformation, the indirect method was also more accurate than the direct method (TRE = 13.5 ± 3.3 versus 20.4 ± 12.8 mm, p = 0.006).Accurate image registration is critical for quantification of regional lung ventilation with hyperpolarized gas MRI within the anatomy delineated by CT. Automatic deformable image registration of hyperpolarized gas MRI to CT via same breath-hold (1)H MRI is more accurate than direct registration. Potential applications include improved multi-modality image fusion, functionally weighted radiotherapy planning, and quantification of lobar ventilation in obstructive airways disease.
Collapse
Affiliation(s)
- Bilal A Tahir
- Academic Unit of Clinical Oncology, University of Sheffield, UK. Academic Unit of Academic Radiology, University of Sheffield, UK
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
De Ruysscher D, Sharifi H, Defraene G, Kerns SL, Christiaens M, De Ruyck K, Peeters S, Vansteenkiste J, Jeraj R, Van Den Heuvel F, van Elmpt W. Quantification of radiation-induced lung damage with CT scans: the possible benefit for radiogenomics. Acta Oncol 2013; 52:1405-10. [PMID: 23957564 DOI: 10.3109/0284186x.2013.813074] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Radiation-induced lung damage (RILD) is an important problem. Although physical parameters such as the mean lung dose are used in clinical practice, they are not suited for individualised radiotherapy. Objective, quantitative measurements of RILD on a continuous instead of on an ordinal, semi-quantitative, semi-subjective scale, are needed. METHODS Hounsfield unit (HU) changes before versus three months post-radiotherapy were correlated per voxel with the radiotherapy dose in 95 lung cancer patients. Deformable registration was used to register pre- and post-CT scans and the density increase was quantified for various dose bins. The dose-response curve for increased HU was quantified using the slope of a linear regression (HU/Gy). The end-point for the toxicity analysis was dyspnoea ≥ grade 2. RESULTS Radiation dose was linearly correlated with the change in HU (mean R(2) = 0.74 ± 0.28). No differences in HU/Gy between groups treated with stereotactic radiotherapy, conventional radiotherapy alone, sequential or concurrent chemo- radiotherapy were observed. In the whole patient group, 33/95 (34.7%) had dyspnoea ≥ G2. Of the 48 patients with a HU/Gy below the median, 16 (33.3%) developed dyspnoea ≥ G2, while in the 47 patients with a HU/Gy above the median, 17 (36.1%) had dyspnoea ≥ G2 (not significant). Individual patients showed a nearly 21-fold difference in radiosensitivity, with HU/Gy ranging from 0 to 10 HU/Gy. CONCLUSIONS HU changes identify objectively the whole range of individual radiosensitivity on a continuous, quantitative scale. CT density changes may allow more robust and accurate radiogenomics studies.
Collapse
Affiliation(s)
- Dirk De Ruysscher
- Radiation Oncology, University Hospitals Leuven/KU Leuven , Leuven , Belgium
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Grau C, Høyer M, Alber M, Overgaard J, Lindegaard JC, Muren LP. Biology-guided adaptive radiotherapy (BiGART)--more than a vision? Acta Oncol 2013; 52:1243-7. [PMID: 23984809 DOI: 10.3109/0284186x.2013.829245] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- Cai Grau
- Department of Oncology, Aarhus University Hospital , Aarhus , Denmark
| | | | | | | | | | | |
Collapse
|
18
|
Mattonen SA, Palma DA, Haasbeek CJA, Senan S, Ward AD. Distinguishing radiation fibrosis from tumour recurrence after stereotactic ablative radiotherapy (SABR) for lung cancer: a quantitative analysis of CT density changes. Acta Oncol 2013; 52:910-8. [PMID: 23106174 DOI: 10.3109/0284186x.2012.731525] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND For patients treated with stereotactic ablative radiotherapy (SABR) for early-stage non-small cell lung cancer, benign computed tomography (CT) changes due to radiation-induced lung injury (RILI) can be difficult to differentiate from recurrence. We measured the utility of CT image feature analysis in differentiating RILI from recurrence, compared to Response Evaluation Criteria In Solid Tumours (RECIST). MATERIALS AND METHODS Twenty-two patients with 24 lesions treated with SABR were selected (11 with recurrence, 13 with substantial RILI). On each follow-up CT, consolidative changes and ground glass opacities (GGO) were contoured. For each lesion, contoured regions were analysed for mean and variation in Hounsfield units (HU), 3D volume, and RECIST size during follow-up. RESULTS One hundred and thirty-six CT scans were reviewed, with a median imaging follow-up of 26 months. The 3D volume and RECIST measures of consolidative changes could significantly distinguish recurrence from RILI, but not until 15 months post-SABR; mean volume at 15 months [all values ± 95% confidence interval (CI)] of 30.1 ± 19.3 cm(3) vs. 5.1 ± 3.6 cm(3) (p = 0.030) and mean RECIST size at 15 months of 4.34 ± 1.13 cm vs. 2.63 ± 0.84 cm (p = 0.028) respectively for recurrence vs. RILI. At nine months post-SABR, patients with recurrence had significantly higher-density consolidative changes (mean at nine months of -96.4 ± 32.7 HU vs. -143.2 ± 28.4 HU for RILI; p = 0.046). They also had increased variability of HU, an image texture metric, measured as the standard deviation (SD) of HU, in the GGO areas (SD at nine months of 210.6 ± 14.5 HU vs. 175.1 ± 18.7 HU for RILI; p = 0.0078). CONCLUSIONS Quantitative changes in mean HU and GGO textural analysis have the potential to distinguish RILI from recurrence as early as nine months post-SABR, compared to 15 months with RECIST and 3D volume. If validated, this approach could allow for earlier detection and salvage of recurrence, and result in fewer unnecessary investigations of benign RILI.
Collapse
Affiliation(s)
- Sarah A Mattonen
- Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada
| | | | | | | | | |
Collapse
|
19
|
Rosenberg L, Tepper J. Present and future innovations in radiation oncology. Surg Oncol Clin N Am 2013; 22:599-618. [PMID: 23622082 DOI: 10.1016/j.soc.2013.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The purpose of this article is to provide a review of innovations in radiation oncology that have been recently adopted as well as those that are likely to be adopted in the near future. Physics and engineering innovations, including image-guidance technologies and charged particle therapy, are discussed. Biologic innovations, including novel radiation sensitizers, functional imaging for use in treatment planning, and altered fractionation, are also discussed.
Collapse
Affiliation(s)
- Lewis Rosenberg
- Department of Radiation Oncology, University of North Carolina, Chapel Hill, NC 27514, USA.
| | | |
Collapse
|
20
|
Partridge M, Powell C, Koopman M, Humbert Vidan L, Newbold K. Technical note: 9-month repositioning accuracy for functional response assessment in head and neck chemoradiotherapy. Br J Radiol 2012; 85:1576-80. [PMID: 23175480 PMCID: PMC3611716 DOI: 10.1259/bjr/47081873] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2012] [Revised: 05/03/2012] [Accepted: 05/29/2012] [Indexed: 01/08/2023] Open
Abstract
The use of thermoplastic immobilisation masks in head and neck radiotherapy is now common practice. The accuracy of these systems has been widely studied, but always within the context and time frame of the radiation delivery-some 6-8 weeks. There is growing current interest in the use of functional imaging to assess the response to treatment, particularly in the head and neck. It is therefore of interest to determine the accuracy with which functional images can be registered to baseline CT over the extended periods of time used for functional response assessment: 3-6 months after radiotherapy. In this study, repeated contrast-enhanced diagnostic quality CT and mid-quality localisation CT from a positron emission tomography/CT scanner were available for five time points over a period of 9 months (before, during and up to 6 months after chemoradiotherapy) for a series of eight patients enrolled in a clinical pilot study. All images were acquired using thermoplastic immobilisation masks. The overall set-up accuracy obtained from this 9-month study of 5.5 ± 3.2 mm (1 standard deviation) and 1.9 ± 1.3° (1 standard deviation) is in agreement with published data acquired over 6-8 weeks. No statistically significant change in set-up error was seen with time. This work indicates that thermoplastic immobilisation masks can be used to accurately align multimodality functional image data for assessment of the response to treatment in head and neck patients over extended follow-up periods.
Collapse
Affiliation(s)
- M Partridge
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, Sutton, UK.
| | | | | | | | | |
Collapse
|
21
|
Collan J, Kapanen M, Mäkitie A, Nyman H, Joensuu H, Tenhunen M, Saarilahti K. Submandibular gland-sparing intensity modulated radiotherapy in the treatment of head and neck cancer: sites of locoregional relapse and survival. Acta Oncol 2012; 51:735-42. [PMID: 22150115 DOI: 10.3109/0284186x.2011.640348] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
BACKGROUND AND PURPOSE To evaluate the patterns of locoregional relapse and survival following submandibular gland (SMG)-sparing intensity modulated radiotherapy (IMRT). PATIENTS AND METHODS Eighty patients with laryngeal (n = 15), oropharyngeal (n = 50), hypopharyngeal (n = 11) or nasopharyngeal cancer (n = 4) were treated by submandibular gland-sparing IMRT for head and neck squamous cell cancer between July 2000 and December 2008. All patients were treated by bilateral IMRT. Thirty-nine (49%) received definitive radiotherapy (RT) and 41 (51%) postoperative RT. The contralateral parotid gland (PG) and SMG were included in the dose optimization planning program with intent to keep the mean doses for PG and SMG below 23 Gy and 28-30 Gy, respectively. The ipsilateral glands were also spared when considered feasible. RESULTS During a median follow-up time of 51 months (range, 24-117 months) nine local recurrent tumors were observed. Four of these nine patients were salvaged by surgery with no further recurrence. All local recurrences were located within the high-dose CTVs. None of the locally recurrent cancers were located at the vicinity of the spared PGs or SMGs. No recurrent tumors were observed in the contralateral neck. The Kaplan-Meier estimate for local control at five years following IMRT was 88% for the whole cohort and the corresponding figure for local control following salvage surgery was 94%. The estimates for five-year overall survival and disease-specific survival were 85% and 90%, respectively. CONCLUSION In selected head and neck cancer patients who are estimated to have a low risk of cancer recurrence at the nodal levels I-II and who are treated with SMG-sparing IMRT the risk of cancer recurrence at the vicinity of the spared salivary glands is low.
Collapse
Affiliation(s)
- Juhani Collan
- Department of Oncology, Helsinki University Central Hospital, Finland
| | | | | | | | | | | | | |
Collapse
|
22
|
Holgersson G, Hoye E, Bergqvist M, Ekman S, Nyman J, Helsing M, Friesland S, Holgersson M, Ekberg L, Blystad T, Ewers SB, Mörth C, Löden B, Henriksson R, Bergström S. Swedish Lung Cancer Radiation Study Group: predictive value of age at diagnosis for radiotherapy response in patients with non-small cell lung cancer. Acta Oncol 2012; 51:759-67. [PMID: 22793039 DOI: 10.3109/0284186x.2012.681064] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
INTRODUCTION The aim of the present study was to investigate the impact of age at diagnosis on prognosis in patients treated with curatively intended radiotherapy for NSCLC. MATERIAL AND METHODS This is a joint effort among all the Swedish Oncology Departments that includes all identified patients with a diagnosed non-small cell lung cancer that have been subjected to curatively intended irradiation (≥50 Gy) treated during 1990 to 2000. Included patients had a histopathological/cytological diagnosis date as well as a death date or a last follow-up date. The following variables were studied in relation to overall and disease-specific survival: age, gender, histopathology, time period, smoking status, stage and treatment. RESULTS The median overall survival of all 1146 included patients was 14.7 months, while the five-year overall survival rate was 9.5%. Younger patients (<55 years), presented with a more advanced clinical stage but had yet a significantly better overall survival compared with patients in the age groups 55-64 years (p = 0.035) and 65-74 years (p = 0.0097) in a multivariate Cox regression analysis. The overall survival of patients aged ≥75 years was comparable to those aged <55 years. CONCLUSION In this large retrospective study we describe that patients younger than 55 years treated with curatively intended radiotherapy for NSCLC have a better overall survival than patients aged 55-64 and 65-74 years and that younger patients seem to benefit more from the addition of surgery and/or chemotherapy to radiotherapy. Due to the exploratory nature of the study, these results should be confirmed in future prospective trials.
Collapse
|
23
|
Høyer M, Muren LP. Stereotactic body radiation therapy--a discipline with Nordic origin and profile. Acta Oncol 2012; 51:564-7. [PMID: 22574782 DOI: 10.3109/0284186x.2012.684869] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
24
|
Høyer M, Thor M, Thörnqvist S, Søndergaard J, Lassen-Ramshad Y, Paul Muren L. Advances in radiotherapy: from 2D to 4D. Cancer Imaging 2011; 11 Spec No A:S147-52. [PMID: 22185864 PMCID: PMC3266568 DOI: 10.1102/1470-7330.2011.9036] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Imaging techniques are increasingly integrated into modern radiotherapy (RT). Multimodal imaging is used to define the target for RT planning and imaging technology is also being integrated into linear accelerators, with the purpose to ensure delivery of radiation with high geometric accuracy. The integration of imaging in RT calls for a stronger collaboration between diagnostic radiologists and the professions involved in RT.
Collapse
Affiliation(s)
- Morten Høyer
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark.
| | | | | | | | | | | |
Collapse
|
25
|
Møller DS, Khalil AA, Knap MM, Muren LP, Hoffmann L. A planning study of radiotherapy dose escalation of PET-active tumour volumes in non-small cell lung cancer patients. Acta Oncol 2011; 50:883-8. [PMID: 21767188 DOI: 10.3109/0284186x.2011.581694] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
BACKGROUND Patients with non-small cell lung cancer (NSCLC) have poor prognosis partly because of high local failure rates. Escalating the dose to the tumour may decrease the local failure rates and thereby, improve overall survival, but the risk of complications will limit the possibility to dose-escalate a broad range of patients. Escalating only PET-active areas of the tumour may increase the potential for reaching high doses for a variety of tumour sizes and locations. MATERIAL AND METHODS Ten patients were randomly chosen for a dose escalation planning study. A planning target volume (PTV) was defined on the mid-ventilation scan of a four-dimensional computed tomography (4D-CT) scan and a boost planning target volume (PTV-boost) was defined based on a positron emission tomography computed tomography (PET-CT) scan. Treatment plans were created aiming to reach the highest achievable of 74 Gy, 78 Gy or 82 Gy in 2 Gy per fraction prescribed to the PTV-boost without compromising normal tissue constraints and with the PTV prescribed in all cases a biological equivalent dose in 2 Gy fractions of 66 Gy. RESULTS Nine of ten patients could be escalated to the highest dose level (82 Gy), while one patient was limited by the oesophagus dose constraint and could only reach 74 Gy. Four patients could be dose-escalated above 82 Gy without compromising normal tissue constraints. CONCLUSION Dose-escalating only the PET-active areas of lung tumours to doses of 82 Gy while respecting normal tissue constraints is feasible, also in a series of unselected patients including cases with relatively large tumours.
Collapse
Affiliation(s)
- Ditte Sloth Møller
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark.
| | | | | | | | | |
Collapse
|
26
|
Nyeng TB, Kallehauge JF, Høyer M, Petersen JBB, Poulsen PR, Muren LP. Clinical validation of a 4D-CT based method for lung ventilation measurement in phantoms and patients. Acta Oncol 2011; 50:897-907. [PMID: 21767190 DOI: 10.3109/0284186x.2011.577096] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Lung cancer patients referred to radiotherapy (RT) often present with regional lung function deficits, and it is therefore of interest to image their lung function prior to treatment. In this study a method was developed that uses a deformable image registration (DIR) between the peak-inhale and peak-exhale phases of a thoracic four-dimensional computed tomography (4D-CT) scan to extract ventilation information. The method calculates the displacement vector fields (DVFs) resulting from the DIR using the Jacobian map approach in order to extract information regarding regional lung volume change. MATERIAL AND METHODS The DVFs resulting from DIRs were analysed to compute the Jacobian determinant of vectors in the field, thus obtaining a map of the vector gradients of the entire registered CT image, i.e. voxel-wise local volume change. Geometric and quantitative validation was achieved using images of both phantoms and patients. In the phantom studies, translations and deformations of known size and direction were introduced to validate both the DIR algorithm and the method as a whole. Furthermore, five patients underwent 4D-CT for planning of stereotactic body RT (SBRT). The patients were immobilised in a stereotactic body frame (SBF) and for each patient, two thoracic 4D-CT scans were acquired, one scan with respiration restricted by an abdominal compression plate and the other under free breathing. RESULTS In the phantom studies deformation errors were found to be of the order of the expected precision of 3 mm, corresponding to the image slice distance, in lateral and vertical directions. For the longitudinal direction a more pronounced discrepancy was observed, with the algorithm predicting displacement lengths of less than half of the physically introduced deformation. Qualitatively the method performed as expected. In the patient study an inverse consistency test showed deviations of up to 5.8 mm, i.e. almost twice the image slice separation. Jacobian maps of the patient images indicated well-ventilated areas as anatomically expected. CONCLUSION The established method provides a means of using a (commercially available) DIR algorithm to obtain a quantitative measure of local lung volume change. With further phantom and patient validation studies, quantitative maps of specific ventilation should be possible to produce and use in a clinical setting.
Collapse
Affiliation(s)
- Tine B Nyeng
- Departments of Medical Physics and Oncology, Aarhus University Hospital/Aarhus University, Aarhus, Denmark
| | | | | | | | | | | |
Collapse
|
27
|
Ihalainen TM, Lönnroth NT, Peltonen JI, Uusi-Simola JK, Timonen MH, Kuusela LJ, Savolainen SE, Sipilä OE. MRI quality assurance using the ACR phantom in a multi-unit imaging center. Acta Oncol 2011; 50:966-72. [PMID: 21767198 DOI: 10.3109/0284186x.2011.582515] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Magnetic resonance imaging (MRI) instrumentation is vulnerable to technical and image quality problems, and quality assurance is essential. In the studied regional imaging center the long-term quality assurance has been based on MagNET phantom measurements. American College of Radiology (ACR) has an accreditation program including a standardized image quality measurement protocol and phantom. The ACR protocol includes recommended acceptance criteria for clinical sequences and thus provides possibility to assess the clinical relevance of quality assurance. The purpose of this study was to test the ACR MRI phantom in quality assurance of a multi-unit imaging center. MATERIAL AND METHODS The imaging center operates 11 MRI systems of three major manufacturers with field strengths of 3.0 T, 1.5 T and 1.0 T. Images of the ACR phantom were acquired using a head coil following the ACR scanning instructions. Both ACR T1- and T2-weighted sequences as well as T1- and T2-weighted brain sequences in clinical use at each site were acquired. Measurements were performed twice. The images were analyzed and the results were compared with the ACR acceptance levels. RESULTS The acquisition procedure with the ACR phantom was faster than with the MagNET phantoms. On the first and second measurement rounds 91% and 73% of the systems passed the ACR test. Measured slice thickness accuracies were not within the acceptance limits in site T2 sequences. Differences in the high contrast spatial resolution between the ACR and the site sequences were observed. In 3.0 T systems the image intensity uniformity was slightly lower than the ACR acceptance limit. CONCLUSION The ACR method was feasible in quality assurance of a multi-unit imaging center and the ACR protocol could replace the MagNET phantom tests. An automatic analysis of the images will further improve cost-effectiveness and objectiveness of the ACR protocol.
Collapse
|