1
|
Takara Y, Yunaiyama D, Yasutomi M, Arai T, Nara K, Nakamura S, Saguchi T, Nakai M, Saito K. Development of bacteriostatic central venous port using photobiomodulation: a comparative in vitro study. Lasers Med Sci 2024; 39:259. [PMID: 39419958 PMCID: PMC11486815 DOI: 10.1007/s10103-024-04206-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 10/03/2024] [Indexed: 10/19/2024]
Abstract
Photobiomodulation (PBM) occurs when a cell is exposed to low energy intensities. A novel central venous port (CVP) with light-emitting diodes (LEDs) that emits red light with a wavelength of 680 nm via wireless energy transmission technology has been established. This comparative in vitro study examined whether PBM can reduce the growth of methicillin-resistant Staphylococcus aureus (MRSA), a common cause of central venous (CV) infections, in vitro. In this comparative in vitro study, the red light with a wavelength of 680 nm was used to irradiate an MRSA suspension in phosphate-buffered saline for 7.5, 15, 30, or 60 min in a 3.5 cm Petri dish with an area of 8.5 cm2. The total energy was 85 J at 7.5 min, 170 J at 15 min, 340 J at 30 min, and 680 J at 60 min. Six dishes for each time and 6 temperature-controlled samples were prepared. Each sample was incubated overnight at 37℃. The Shapiro-wilk test was used to determine whether the data were normally distributed. The numbers of colonies were counted and compared using one-factor ANOVA and Bonferroni's post-hoc test. The mean numbers of colonies in the control group were 60.3, where the numbers of colonies in the irradiated group were 51.4 at 7.5 min, 53.5 at 15 min, 44.6 at 30 min, 34.3 at 60 min. The mean number of colonies in the 60 min irradiated group differed significantly from that in the control, 7.5 min, and 15 min groups. The Bonferroni's post-hoc test showed significant difference in the number of colonies between control vs. 30 min control vs. 60 min, 7.5 min vs. 60 min, 15 min vs. 60 min. PBM with 680 nm LEDs on MRSA for 340 J at 30 min and 680 J at 60 min inhibited the growth of cell colonies. These findings support the use of photobiomodulation in Central venous port to prevent CV access port-Blood stream infection.
Collapse
Affiliation(s)
- Yuki Takara
- Department of Radiology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku, Tokyo, 160-0023, Japan.
| | - Daisuke Yunaiyama
- Department of Radiology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku, Tokyo, 160-0023, Japan
| | - Mika Yasutomi
- Department of Radiology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku, Tokyo, 160-0023, Japan
| | - Tsunenori Arai
- Faculty of Science and Technology, Keio University, Yokohama, Japan
- Department of Life-science, Furukawa Electric Co. Ltd, Tokyo, Japan
| | - Kazutaka Nara
- Department of Life-science, Furukawa Electric Co. Ltd, Tokyo, Japan
| | - Shigeki Nakamura
- Department of Microbiology, Tokyo Medical University, Tokyo, Japan
| | - Toru Saguchi
- Department of Radiology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku, Tokyo, 160-0023, Japan
| | - Motoki Nakai
- Department of Radiology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku, Tokyo, 160-0023, Japan
| | - Kazuhiro Saito
- Department of Radiology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku, Tokyo, 160-0023, Japan
| |
Collapse
|
2
|
Heng TH, Loh MHY, Chua YY, Tan BK, Tan BS. Infection of a venous port - beware of the Mycobacterium. J Radiol Case Rep 2022; 16:1-10. [PMID: 36324604 PMCID: PMC9584557 DOI: 10.3941/jrcr.v16i9.4587] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2025] Open
Abstract
An 84-year-old female with metastatic left breast cancer underwent a venous port insertion for chemotherapy. The port was inserted using standard techniques with image guidance under local anesthesia. She presented after 36 days with evidence of infection. A limited bedside ultrasound demonstrated free fluid surrounding the port. The port was subsequently removed the same day, at which time pus was expressed from the subcutaneous pocket. The culture from the pus grew Mycobacterium abscessus. She required removal of the port and wound debridement, wound dressings and a prolonged course of antibiotics. Mycobacterium abscessus is a group of rapidly growing, multidrug-resistant, non-tuberculous mycobacteria that are also relatively resistant to standard skin disinfectants. In recent years, this organism has been increasingly reported as the culprit in post-operative or post-procedural infections. Treatment is challenging due to multidrug resistance, and requires an extensive course of intravenous antimicrobial and macrolide-based combination therapy followed by oral antimicrobial therapy. Early treatment is essential as progression may result in disseminated infection. We discuss the peri-operative and post-operative care required in preventing and treating infection with this organism.
Collapse
Affiliation(s)
- Tseng Hui Heng
- Singapore General Hospital, Department of Vascular and Interventional Radiology, Singapore
| | - Marcus Hin Yeung Loh
- Singapore General Hospital, Department of Vascular and Interventional Radiology, Singapore
| | - Ying Ying Chua
- Singapore General Hospital, Department of Infectious Diseases, Singapore
| | - Bien Keem Tan
- Singapore General Hospital, Department of Plastic, Reconstruction & Aesthetic Surgery, Singapore
| | - Bien Soo Tan
- Singapore General Hospital, Department of Vascular and Interventional Radiology, Singapore
| |
Collapse
|
3
|
Augustin AM, Kertels O, Wiegering V, Thurner A, Kickuth R. Percutaneous implantation of peripherally inserted totally implantable venous access systems in the forearm in adolescent patients. Pediatr Radiol 2022; 52:1550-1558. [PMID: 35368211 PMCID: PMC9271099 DOI: 10.1007/s00247-022-05321-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 01/14/2022] [Accepted: 02/11/2022] [Indexed: 12/19/2022]
Abstract
BACKGROUND Children with different underlying malignant diseases require long-term central venous access. As for port systems in a pectoral position, peripherally implanted port systems in the forearm revealed high levels of technical and clinical success in adult cohorts. OBJECTIVE To investigate the technical and clinical outcomes of percutaneous central venous port implantation in the forearm in adolescents. MATERIALS AND METHODS Between April 2010 and August 2020, 32 children ages 9 to 17 years with underlying malignancy received 35 totally implantable venous access ports (TIVAPs) in the forearm. All venous port systems were peripherally inserted under ultrasound guidance. Correct catheter placement was controlled by fluoroscopy. As primary endpoints, the technical success, rate of complications and catheter maintenance were analyzed. Secondary endpoints were the side of implantation, vein of catheter access, laboratory results on the day of the procedure, procedural radiation exposure, amount of contrast agent and reasons for port device removal. RESULTS Percutaneous TIVAP placement under sonographic guidance was technically successful in 34 of 35 procedures (97.1%). Procedure-related complications did not occur. During the follow-up, 13,684 catheter days were analyzed, revealing 11 complications (0.8 per 1,000 catheter-duration days), Of these 11 complications, 7 were major and 10 occurred late. In seven cases, the port device had to be removed; removal-related complications did not occur. CONCLUSION Peripheral TIVAP placement in the forearms of children is a feasible, effective and safe technique with good midterm outcome. As results are comparable with standard access routes, this technique may be offered as an alternative when intermittent venous access is required.
Collapse
Affiliation(s)
- Anne Marie Augustin
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Strasse 6, DE 97080, Würzburg, Germany.
| | - Olivia Kertels
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Strasse 6, DE 97080 Würzburg, Germany
| | - Verena Wiegering
- Department of Pediatrics, University Hospital of Würzburg, Würzburg, Germany
| | - Annette Thurner
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Strasse 6, DE 97080 Würzburg, Germany
| | - Ralph Kickuth
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Strasse 6, DE 97080 Würzburg, Germany
| |
Collapse
|
4
|
Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure. JOURNAL OF HEALTHCARE ENGINEERING 2020; 2020:9180856. [PMID: 32676177 PMCID: PMC7346251 DOI: 10.1155/2020/9180856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 05/29/2020] [Accepted: 06/15/2020] [Indexed: 11/17/2022]
Abstract
Background A conventional centrally inserted central catheter (CICC) is frequently used to measure central venous pressure (CVP) to monitor the cardiocirculatory status of patients. The tip of the totally implanted port (TIP) is inserted at the same location in the superior vena cava as that of a CICC, and the TIP has been implanted in many patients with cancer. Measurements of CVP using CICC (CICCP) and TIP (TIPP) may be closely related. Material and Methods. Ten patients with TIPs in an intensive care unit were prospectively studied, and 121 records of 4536 paired CICCP and TIPP measurements were collected. A bench test in a static or dynamic setting was performed, and 598 paired measurements taken using CICC and TIP were recorded. Results The measurement of TIPP was highly correlated with that of CICCP in patients with cancer, especially those in a calm state. Patients with a calm state and ≥3 consecutive identical TIPP were recorded (≥30 seconds), and 90% of the mean difference between CICCP and TIPP was ≤2 mmHg. The pressure measurements recorded using CICC and TIP were identical in both the static and dynamic bench tests. Conclusions TIP may be an alternative to CICC for measuring CVP.
Collapse
|
5
|
Ariza‐Heredia EJ, Chemaly RF. Update on infection control practices in cancer hospitals. CA Cancer J Clin 2018; 68:340-355. [PMID: 29985544 PMCID: PMC7162018 DOI: 10.3322/caac.21462] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 04/12/2018] [Accepted: 05/09/2018] [Indexed: 12/21/2022] Open
Abstract
Therapies in oncology have evolved rapidly over the last years. At the same pace, supportive care for patients receiving cancer therapy has also evolved, allowing patients to safely receive the newest advances in treatment in both an inpatient and outpatient basis. The recognition of the role of infection control and prevention (ICP) in the outcomes of patients living with cancer has been such that it is now a requirement for hospitals and involves multidisciplinary groups. Some unique aspects of ICP for patients with cancer that have gained momentum over the past few decades include catheter-related infections, multidrug-resistant organisms, community-acquired viral infections, and the impact of the health care environment on the horizontal transmission of organisms. Furthermore, as the potential for infections to cross international borders has increased, alertness for outbreaks or new infections that occur outside the area have become constant. As the future approaches, ICP in immunocompromised hosts will continue to integrate emerging disciplines, such as antibiotic stewardship and the microbiome, and new techniques for environmental cleaning and for controlling the spread of infections, such as whole-genome sequencing. CA Cancer J Clin 2018;000:000-000. © 2018 American Cancer Society.
Collapse
Affiliation(s)
- Ella J. Ariza‐Heredia
- Associate Professor, Department of Infectious Diseases, Infection Control, and Employee HealthThe University of Texas MD Anderson Cancer CenterHoustonTX
| | - Roy F. Chemaly
- Professor, Department of Infectious Diseases, Infection Control, and Employee HealthThe University of Texas MD Anderson Cancer CenterHoustonTX
| |
Collapse
|
6
|
Role of Lock Therapy for Long-Term Catheter-Related Infections by Multidrug-Resistant Bacteria. Antimicrob Agents Chemother 2018; 62:AAC.00569-18. [PMID: 29987150 DOI: 10.1128/aac.00569-18] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2018] [Accepted: 06/29/2018] [Indexed: 11/20/2022] Open
Abstract
The management of long-term central venous catheter (LTCVC) infections by multidrug-resistant (MDR) bacteria in cancer patient is a challenge. The objectives of this study were to analyze outcomes in cancer patients with LTCVC-associated infection, identify risks for unfavorable outcomes, and determine the impact of MDR bacteria and antibiotic lock therapy (ALT) in managing such infections. We evaluated all LTCVC-associated infections treated between January 2009 and December 2016. Infections were reported in accordance with international guidelines for catheter-related infections. The outcome measures were 30-day mortality and treatment failure. We analyzed risk factors by Cox forward-stepwise regression. We identified 296 LTCVC-associated infections; 212 (71.6%) were classified as bloodstream infections (BSIs). The most common agent was Staphylococcus aureus Forty-six (21.7%) infections were due to MDR Gram-negative bacteria. ALT was used in 62 (29.2%) patients, with a 75.9% success rate. Risk factors identified for failure of the initial treatment were having a high sequential organ failure assessment (SOFA) score at diagnosis of infection and being in palliative care; introduction of ALT at the start of treatment was identified as a protective factor. Risk factors identified for 30-day mortality after LTCVC-associated infection were a high SOFA score at diagnosis, infection with MDR bacteria, and palliative care; introduction of ALT at the start of treatment, hematological malignancies, and adherence to an institutional protocol for the management of LTCVC-associated infection were identified as protective factors. Despite the high incidence of infection with MDR bacteria, ALT improves the outcome of LTCVC-associated infection in cancer patients.
Collapse
|
7
|
Wang TY, Lee KD, Chen PT, Chen MC, Chen YY, Huang CE, Kuan FC, Chen CC, Lu CH. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients. J Formos Med Assoc 2015; 114:1055-1060. [PMID: 26253646 DOI: 10.1016/j.jfma.2015.06.013] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Revised: 06/26/2015] [Accepted: 06/30/2015] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND/PURPOSE Cytotoxic chemotherapy via central venous access ports is an important part of the standard treatment for most cancers, but it is accompanied with the risk of infections. This study aimed to analyze the incidence and risk factors for central venous access port-related infection (CPI) among Chinese patients receiving cytotoxic chemotherapy. METHODS Between January 1, 2002 and December 31, 2005 a total of 1391 cancer patients with 1449 totally implantable central venous access ports were evaluated. The log-rank test and Cox proportional hazards model were used for the analyses of risk factors. RESULTS The overall CPI incidence rate was 0.21 per 1000 catheter-days. Hematological malignancies and head and neck cancer were associated with an increased risk of CPI (hazard ratio 4.00 and 4.11, respectively, both p < 0.001) and less infection-free catheter longevity (p < 0.001) compared with other cancer types. Chemotherapy in an adjuvant setting was associated with a lower risk of infection than for patients in a nonadjuvant setting (p < 0.001). The most common pathogens isolated from CPI were Pseudomonas aeruginosa and Candida. CONCLUSION Infection remains to be a challenging issue for totally implantable central venous ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings.
Collapse
Affiliation(s)
- Ting-Yao Wang
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC
| | - Kuan-Der Lee
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC
| | - Ping-Tsung Chen
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC
| | - Min-Chi Chen
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC
| | - Yi-Yang Chen
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC
| | - Cih-En Huang
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC
| | - Feng-Che Kuan
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC
| | - Chih-Cheng Chen
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC
| | - Chang Hsien Lu
- Division of Hematology Oncology, Department of Medicine, Chang Gung Memorial Hospital-Chiayi, Puzi City, Taiwan, ROC.
| |
Collapse
|