1
|
Lakis R, Sauvage FL, Pinault E, Marquet P, Saint-Marcoux F, El Balkhi S. Absolute Quantification of Human Serum Albumin Isoforms by Internal Calibration Based on a Top-Down LC-MS Approach. Anal Chem 2024; 96:746-755. [PMID: 38166371 DOI: 10.1021/acs.analchem.3c03933] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Well-characterized biomarkers using reliable quantitative methods are essential for the management of various pathologies such as diabetes, kidney, and liver diseases. Human serum albumin (HSA) isoforms are gaining interest as biomarkers of advanced liver pathologies. In view of the structural alterations observed for HSA, insights into its isoforms are required to establish them as reliable biomarkers. Therefore, a robust absolute quantification method seems necessary. In this study, we developed and validated a far more advanced top-down liquid chromatography-mass spectrometry (LC-MS) method for the absolute quantification of HSA isoforms, using myoglobin (Mb) as an internal standard for quantification and for mass recalibration. Two different quantification approaches were investigated based on peak integration from the deconvoluted spectrum and extracted ion chromatogram (XIC). The protein mixture human serum albumin/myoglobin eluted in well-shaped separated peaks. Mb allowed a systematic mass recalibration for every sample, resulting in extremely low mass deviations compared to conventional deconvolution-based methods. In total, eight HSA isoforms of interest were quantified. Specific-isoform calibration curves showing good linearity were obtained by using the deconvoluted peaks. Noticeably, the HSA ionization behavior appeared to be isoform-dependent, suggesting that the use of an enriched isoform solution as a calibration standard for absolute quantification studies of HSA isoforms is necessary. Good repeatability, reproducibility, and accuracy were observed, with better sensitivity for samples with low albumin concentrations compared to routine biochemical assays. With a relatively simple workflow, the application of this method for absolute quantification shows great potential, especially for HSA isoform studies in a clinical context, where a high-throughput method and sensitivity are needed.
Collapse
Affiliation(s)
- Roy Lakis
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
| | - François-Ludovic Sauvage
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
| | - Emilie Pinault
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
| | - Pierre Marquet
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
- Department of Pharmacology, Toxicology and Pharmacovigilance, CHU Limoges, Limoges 87000, France
| | - Franck Saint-Marcoux
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
- Department of Pharmacology, Toxicology and Pharmacovigilance, CHU Limoges, Limoges 87000, France
| | - Souleiman El Balkhi
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
- Department of Pharmacology, Toxicology and Pharmacovigilance, CHU Limoges, Limoges 87000, France
| |
Collapse
|
2
|
Shimomura T, Sekiguchi M, Honda R, Yamazaki M, Yokoyama M, Uchiyama S. Estimation of the Viscosity of an Antibody Solution from the Diffusion Interaction Parameter. Biol Pharm Bull 2022; 45:1300-1305. [DOI: 10.1248/bpb.b22-00263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
| | | | - Reisa Honda
- Department of Pharmaceutical Technology, Astellas Pharma Inc
| | - Miki Yamazaki
- Department of Pharmaceutical Technology, Astellas Pharma Inc
| | - Masami Yokoyama
- Department of Biotechnology, Graduate School of Engineering, Osaka University
| | - Susumu Uchiyama
- Department of Biotechnology, Graduate School of Engineering, Osaka University
| |
Collapse
|
3
|
Das TK, Chou DK, Jiskoot W, Arosio P. Nucleation in protein aggregation in biotherapeutic development: a look into the heart of the event. J Pharm Sci 2022; 111:951-959. [DOI: 10.1016/j.xphs.2022.01.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 01/24/2022] [Accepted: 01/24/2022] [Indexed: 12/26/2022]
|
4
|
Chen H, Lin Y, Long YT, Minteer SD, Ying YL. Nanopore-based measurement of the interaction of P450cam monooxygenase and putidaredoxin at the single-molecule level. Faraday Discuss 2021; 233:295-302. [PMID: 34889330 DOI: 10.1039/d1fd00042j] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Protein-protein interactions occur in a wide range of biological processes and are of great significance to life function. Characterization of transient protein-protein interactions remains a significant barrier to our understanding of cellular processes. Nanopores provide unique nanoscale environments that accommodate single molecules from the surrounding bulk solution. This method permits label-free sensing at the single-molecule level with extremely high sensitivity. Herein, the interaction between a single P450cam monooxygenase and its redox partner putidaredoxin (Pdx) was monitored via transient ionic current by using functionalized glass nanopores. Results show that the volume of P450cam determines the blockage current while the interactions between the P450cam and Pdx give a long blockage duration. Our glass nanopore sensor with adjustable diameter could be applied for real-time sensing of protein-protein interactions between individual proteins with a wide range of molecular weight.
Collapse
Affiliation(s)
- Hui Chen
- Department of Chemistry, University of Utah, USA.
| | - Yao Lin
- Department of Chemistry, University of Utah, USA. .,State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, China.
| | - Yi-Tao Long
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, China.
| | | | - Yi-Lun Ying
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, China. .,Chemistry and Biomedicine Innovation Center, Nanjing University, China
| |
Collapse
|
5
|
Pusara S, Yamin P, Wenzel W, Krstić M, Kozlowska M. A coarse-grained xDLVO model for colloidal protein-protein interactions. Phys Chem Chem Phys 2021; 23:12780-12794. [PMID: 34048523 DOI: 10.1039/d1cp01573g] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Colloidal protein-protein interactions (PPIs) of attractive and repulsive nature modulate the solubility of proteins, their aggregation, precipitation and crystallization. Such interactions are very important for many biotechnological processes, but are complex and hard to control, therefore, difficult to be understood in terms of measurements alone. In diluted protein solutions, PPIs can be estimated from the osmotic second virial coefficient, B22, which has been calculated using different methods and levels of theory. The most popular approach is based on the Derjaguin-Landau-Verwey-Overbeek (DLVO) theory and its extended versions, i.e. xDLVO. Despite much efforts, these models are not fully quantitative and must be fitted to experiments, which limits their predictive value. Here, we report an extended xDLVO-CG model, which extends existing models by a coarse-grained representation of proteins and the inclusion of an additional ion-protein dispersion interaction term. We demonstrate for four proteins, i.e. lysozyme (LYZ), subtilisin (Subs), bovine serum albumin (BSA) and immunoglobulin (IgG1), that semi-quantitative agreement with experimental values without the need to fit to experimental B22 values. While most likely not the final step in the nearly hundred years of research in PPIs, xDLVO-CG is a step towards predictive PPIs calculations that are transferable to different proteins.
Collapse
Affiliation(s)
- Srdjan Pusara
- Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
| | - Peyman Yamin
- Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
| | - Wolfgang Wenzel
- Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
| | - Marjan Krstić
- Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany. and Institute of Theoretical Solid State Physics, Karlsruhe Institute of Technology (KIT), Wolfgang-Gaede-Str. 1, 76131 Karlsruhe, Germany
| | - Mariana Kozlowska
- Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
| |
Collapse
|
6
|
Kaiser W, Schultz-Fademrecht T, Blech M, Buske J, Garidel P. Investigating photodegradation of antibodies governed by the light dosage. Int J Pharm 2021; 604:120723. [PMID: 34022254 DOI: 10.1016/j.ijpharm.2021.120723] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 05/16/2021] [Accepted: 05/17/2021] [Indexed: 12/22/2022]
Abstract
The present study investigated the photodegradation of three different monoclonal antibodies (mAb) by visible light. Several chromatographic techniques, such as size-exclusion and hydrophobic interaction chromatography as well as mass spectrometry were used to measure relative changes of various oxidation related monoclonal antibody species. The results show that visible light is indeed capable of inducing the formation of protein photo-oxidation products, such as acidic, basic, hydrophilic, and several other protein species with altered physicochemical properties. Although, the formation rate of degradants of these three protein species was dependent on the light source's intensity (I), their yield is clearly correlated to the applied light dosage (ld), which is defined as the product of light intensity I and irradiation time t (light dosage = I·t). Hence, our findings indicate that the degradation of monoclonal antibodies can be described according to the Bunsen-Roscoe reciprocity law. This correlation can be useful to assess the impact of photodegradation of biologics with regards to changes in light intensity and/or duration of light exposure of the protein, e.g. during the manufacturing of biologics.
Collapse
Affiliation(s)
- Wolfgang Kaiser
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, PDB, D-88397 Biberach an der Riss, Germany
| | | | - Michaela Blech
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, PDB, D-88397 Biberach an der Riss, Germany
| | - Julia Buske
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, PDB, D-88397 Biberach an der Riss, Germany
| | - Patrick Garidel
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, PDB, D-88397 Biberach an der Riss, Germany.
| |
Collapse
|
7
|
Dauer K, Kamm W, Wagner KG, Pfeiffer-Marek S. High-Throughput Screening for Colloidal Stability of Peptide Formulations Using Dynamic and Static Light Scattering. Mol Pharm 2021; 18:1939-1955. [PMID: 33789055 DOI: 10.1021/acs.molpharmaceut.0c01028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Selection of an appropriate formulation to stabilize therapeutic proteins against aggregation is one of the most challenging tasks in early-stage drug product development. The amount of aggregates is more difficult to quantify in the case of peptides due to their small molecular size. Here, we investigated the suitability of diffusion self-interaction parameters (kD) and osmotic second virial coefficients (B22) for high-throughput (HT) screening of peptide formulations regarding their aggregation risk. These parameters were compared to the effect of thermal stress on colloidal stability. The formulation matrix comprised six buffering systems at two selected pH values, four tonicity agents, and a common preservative. The results revealed that electrostatic interactions are the main driver to control colloidal stability. Preferred formulations consisted of acetate and succinate buffer at pH 4.5 combined with glycerol or mannitol and optional m-cresol. kD proved to be a suitable surrogate for B22 as an indicator of high colloidal stability in the case of peptides as was previously described for globular proteins and antibodies. Formulation assessment solely based on kD obtained by HT methods offers important insights into the optimization of colloidal stability during the early development of peptide-based liquid formulations and can be performed with a limited amount of peptide (∼360 mg).
Collapse
Affiliation(s)
- Katharina Dauer
- Department of Pharmaceutical Technology and Biopharmaceutics, Institute of Pharmacy, University of Bonn, Gerhard-Domagk-Str. 3, 53121 Bonn, Germany.,Pharmaceutical Development Platform, Tides Drug Product Pre-Development Sciences, Sanofi-Aventis Deutschland GmbH, Industriepark Höchst, 65926 Frankfurt am Main, Germany
| | - Walter Kamm
- Pharmaceutical Development Platform, Tides Drug Product Pre-Development Sciences, Sanofi-Aventis Deutschland GmbH, Industriepark Höchst, 65926 Frankfurt am Main, Germany
| | - Karl Gerhard Wagner
- Department of Pharmaceutical Technology and Biopharmaceutics, Institute of Pharmacy, University of Bonn, Gerhard-Domagk-Str. 3, 53121 Bonn, Germany
| | - Stefania Pfeiffer-Marek
- Pharmaceutical Development Platform, Tides Drug Product Pre-Development Sciences, Sanofi-Aventis Deutschland GmbH, Industriepark Höchst, 65926 Frankfurt am Main, Germany
| |
Collapse
|
8
|
Wu HH, Garidel P, Michaela B. HP-β-CD for the formulation of IgG and Ig-based biotherapeutics. Int J Pharm 2021; 601:120531. [PMID: 33775727 DOI: 10.1016/j.ijpharm.2021.120531] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 03/11/2021] [Accepted: 03/20/2021] [Indexed: 12/14/2022]
Abstract
The main challenge to develop HCF for IgG and Ig-based therapeutics is to achieve essential solubility, viscosity and stability of these molecules in order to maintain product quality and meet regulatory requirement during manufacturing, production, storage, shipment and administration processes. The commonly used and FDA approved excipients for IgG and Ig -based therapeutics may no longer fulfil the challenge of HCF development for these molecules to certain extent, especially for some complex Ig-based platforms. 2-Hydroxypropyl beta-cyclodextrin (HP-β-CD) is one of the promising excipients applied recently for HCF development of IgG and Ig-based therapeutics although it has been used for formulation of small synthesized chemical drugs for more than thirty years. This review describes essential aspects about application of HP-β-CD as excipient in pharmaceutical formulation, including physico-chemical properties of HP-β-CD, supply chain, regulatory, patent landscape, marketed drugs with HP-β-CD, analytics and analytical challenges, stability and control strategies, and safety concerns. It also provides an overview of different studies, and outcomes thereof, regarding formulation development for IgGs and Ig-based molecules in liquid and solid (lyophilized) dosage forms with HP-β-CD. The review specifically highlights the challenges for formulation manufacturing of IgG and Ig-based therapeutics with HP-β-CD and identifies areas for future work in pharmaceutical and formulation development.
Collapse
Affiliation(s)
- Helen Haixia Wu
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, Pharmaceutical Development Biologicals, Biberach an der Riss, Germany.
| | - Patrick Garidel
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, Pharmaceutical Development Biologicals, Biberach an der Riss, Germany
| | - Blech Michaela
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, Pharmaceutical Development Biologicals, Biberach an der Riss, Germany
| |
Collapse
|
9
|
Particle Detection and Characterization for Biopharmaceutical Applications: Current Principles of Established and Alternative Techniques. Pharmaceutics 2020; 12:pharmaceutics12111112. [PMID: 33228023 PMCID: PMC7699340 DOI: 10.3390/pharmaceutics12111112] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 11/09/2020] [Accepted: 11/10/2020] [Indexed: 12/30/2022] Open
Abstract
Detection and characterization of particles in the visible and subvisible size range is critical in many fields of industrial research. Commercial particle analysis systems have proliferated over the last decade. Despite that growth, most systems continue to be based on well-established principles, and only a handful of new approaches have emerged. Identifying the right particle-analysis approach remains a challenge in research and development. The choice depends on each individual application, the sample, and the information the operator needs to obtain. In biopharmaceutical applications, particle analysis decisions must take product safety, product quality, and regulatory requirements into account. Biopharmaceutical process samples and formulations are dynamic, polydisperse, and very susceptible to chemical and physical degradation: improperly handled product can degrade, becoming inactive or in specific cases immunogenic. This article reviews current methods for detecting, analyzing, and characterizing particles in the biopharmaceutical context. The first part of our article represents an overview about current particle detection and characterization principles, which are in part the base of the emerging techniques. It is very important to understand the measuring principle, in order to be adequately able to judge the outcome of the used assay. Typical principles used in all application fields, including particle–light interactions, the Coulter principle, suspended microchannel resonators, sedimentation processes, and further separation principles, are summarized to illustrate their potentials and limitations considering the investigated samples. In the second part, we describe potential technical approaches for biopharmaceutical particle analysis as some promising techniques, such as nanoparticle tracking analysis (NTA), micro flow imaging (MFI), tunable resistive pulse sensing (TRPS), flow cytometry, and the space- and time-resolved extinction profile (STEP®) technology.
Collapse
|
10
|
Haryadi BM, Hafner D, Amin I, Schubel R, Jordan R, Winter G, Engert J. Nonspherical Nanoparticle Shape Stability Is Affected by Complex Manufacturing Aspects: Its Implications for Drug Delivery and Targeting. Adv Healthc Mater 2019; 8:e1900352. [PMID: 31410996 DOI: 10.1002/adhm.201900352] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 07/05/2019] [Indexed: 02/04/2023]
Abstract
The shape of nanoparticles is known recently as an important design parameter influencing considerably the fate of nanoparticles with and in biological systems. Several manufacturing techniques to generate nonspherical nanoparticles as well as studies on in vitro and in vivo effects thereof have been described. However, nonspherical nanoparticle shape stability in physiological-related conditions and the impact of formulation parameters on nonspherical nanoparticle resistance still need to be investigated. To address these issues, different nanoparticle fabrication methods using biodegradable polymers are explored to produce nonspherical nanoparticles via the prevailing film-stretching method. In addition, systematic comparisons to other nanoparticle systems prepared by different manufacturing techniques and less biodegradable materials (but still commonly utilized for drug delivery and targeting) are conducted. The study evinces that the strong interplay from multiple nanoparticle properties (i.e., internal structure, Young's modulus, surface roughness, liquefaction temperature [glass transition (Tg ) or melting (Tm )], porosity, and surface hydrophobicity) is present. It is not possible to predict the nonsphericity longevity by merely one or two factor(s). The most influential features in preserving the nonsphericity of nanoparticles are existence of internal structure and low surface hydrophobicity (i.e., surface-free energy (SFE) > ≈55 mN m-1 , material-water interfacial tension <6 mN m-1 ), especially if the nanoparticles are soft (<1 GPa), rough (Rrms > 10 nm), porous (>1 m2 g-1 ), and in possession of low bulk liquefaction temperature (<100 °C). Interestingly, low surface hydrophobicity of nanoparticles can be obtained indirectly by the significant presence of residual stabilizers. Therefore, it is strongly suggested that nonsphericity of particle systems is highly dependent on surface chemistry but cannot be appraised separately from other factors. These results and reviews allot valuable guidelines for the design and manufacturing of nonspherical nanoparticles having adequate shape stability, thereby appropriate with their usage purposes. Furthermore, they can assist in understanding and explaining the possible mechanisms of nonspherical nanoparticles effectivity loss and distinctive material behavior at the nanoscale.
Collapse
Affiliation(s)
- Bernard Manuel Haryadi
- Pharmaceutical Technology and BiopharmaceuticsDepartment of PharmacyLudwig‐Maximilians‐Universität München Butenandtstraße 5 81377 Munich Germany
| | - Daniel Hafner
- Department of ChemistryDresden University of Technology Mommsenstraße 4 01069 Dresden Germany
| | - Ihsan Amin
- Department of ChemistryDresden University of Technology Mommsenstraße 4 01069 Dresden Germany
| | - Rene Schubel
- Department of ChemistryDresden University of Technology Mommsenstraße 4 01069 Dresden Germany
| | - Rainer Jordan
- Department of ChemistryDresden University of Technology Mommsenstraße 4 01069 Dresden Germany
| | - Gerhard Winter
- Pharmaceutical Technology and BiopharmaceuticsDepartment of PharmacyLudwig‐Maximilians‐Universität München Butenandtstraße 5 81377 Munich Germany
| | - Julia Engert
- Pharmaceutical Technology and BiopharmaceuticsDepartment of PharmacyLudwig‐Maximilians‐Universität München Butenandtstraße 5 81377 Munich Germany
| |
Collapse
|
11
|
Hedberg SHM, Brown LG, Meghdadi A, Williams DR. Improved adsorption reactions, kinetics and stability for model and therapeutic proteins immobilised on affinity resins. ADSORPTION 2019; 25:1177-1190. [PMID: 31435138 PMCID: PMC6683242 DOI: 10.1007/s10450-019-00106-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Revised: 04/26/2019] [Accepted: 04/29/2019] [Indexed: 11/29/2022]
Abstract
Protein adsorption on solid state media is important for the industrial affinity chromatography of biotherapeutics and for preparing materials for self-interaction chromatography where fundamental protein solution thermodynamic properties are measured. The adsorption of three model proteins (lysozyme, catalase and BSA) and two antibodies (a monoclonal and a polyclonal antibody) have been investigated on commercial affinity chromatography media with different surface functionalities (Formyl, Tresyl and Amino). Both the extent of protein immobilised (mg protein/ml media) and the reaction kinetics are reported for a range of reaction conditions, including pH, differing buffers as well as the presence of secondary reactants (glutaraldehyde, sodium cyanoborohydride, EDC and NHS). Compared to the reaction conditions recommended by manufacturers as well as those reported in previous published work, significant increases in the extent of protein immobilisation and reaction kinetics are reported here. The addition of glutaraldehyde or sodium cyanoborohydride was found to be especially effective even when not directly needed for the adsorption to happen. For mAb and pIgG, immobilisation levels of 50 and 31 mg of protein/ml of resin respectively were achieved, which are 100% or more than previously reported. Enhanced levels were achieved for lysozyme of 120 mg/ml with very rapid reaction kinetics (< 1 h) with sodium cyanoborohydride. It can be concluded that specific chromatography resins with Tresyl activated support offered enhanced levels of protein immobilisation due to their ability to react to form amine or thio-ether linkages with proteins. Additionally, glutaraldehyde can result in higher immobilisation levels whilst it can also accelerate immobilisation reaction kinetics. ![]()
Collapse
Affiliation(s)
- S. H. M. Hedberg
- Surfaces and Particle Engineering Laboratory, Department of Chemical Engineering, Imperial College London, London, UK
| | - L. G. Brown
- Surfaces and Particle Engineering Laboratory, Department of Chemical Engineering, Imperial College London, London, UK
| | - A. Meghdadi
- Surfaces and Particle Engineering Laboratory, Department of Chemical Engineering, Imperial College London, London, UK
- Present Address: Bioengineering Research Group, Department of Mechanical Engineering, University of Southampton, Southampton, England, UK
| | - D. R. Williams
- Surfaces and Particle Engineering Laboratory, Department of Chemical Engineering, Imperial College London, London, UK
| |
Collapse
|
12
|
Wang W, Ohtake S. Science and art of protein formulation development. Int J Pharm 2019; 568:118505. [PMID: 31306712 DOI: 10.1016/j.ijpharm.2019.118505] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2019] [Revised: 07/08/2019] [Accepted: 07/08/2019] [Indexed: 02/07/2023]
Abstract
Protein pharmaceuticals have become a significant class of marketed drug products and are expected to grow steadily over the next decade. Development of a commercial protein product is, however, a rather complex process. A critical step in this process is formulation development, enabling the final product configuration. A number of challenges still exist in the formulation development process. This review is intended to discuss these challenges, to illustrate the basic formulation development processes, and to compare the options and strategies in practical formulation development.
Collapse
Affiliation(s)
- Wei Wang
- Biological Development, Bayer USA, LLC, 800 Dwight Way, Berkeley, CA 94710, United States.
| | - Satoshi Ohtake
- Pharmaceutical Research and Development, Pfizer Biotherapeutics Pharmaceutical Sciences, Chesterfield, MO 63017, United States
| |
Collapse
|
13
|
Wang W, Roberts CJ. Protein aggregation – Mechanisms, detection, and control. Int J Pharm 2018; 550:251-268. [DOI: 10.1016/j.ijpharm.2018.08.043] [Citation(s) in RCA: 100] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 08/18/2018] [Accepted: 08/20/2018] [Indexed: 12/19/2022]
|
14
|
Blaffert J, Haeri HH, Blech M, Hinderberger D, Garidel P. Spectroscopic methods for assessing the molecular origins of macroscopic solution properties of highly concentrated liquid protein solutions. Anal Biochem 2018; 561-562:70-88. [PMID: 30243977 DOI: 10.1016/j.ab.2018.09.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Revised: 09/08/2018] [Accepted: 09/17/2018] [Indexed: 01/14/2023]
Abstract
In cases of subcutaneous injection of therapeutic monoclonal antibodies, high protein concentrations (>50 mg/ml) are often required. During the development of these high concentration liquid formulations (HCLF), challenges such as aggregation, gelation, opalescence, phase separation, and high solution viscosities are more prone compared to low concentrated protein formulations. These properties can impair manufacturing processes, as well as protein stability and shelf life. To avoid such unfavourable solution properties, a detailed understanding about the nature of these properties and their driving forces are required. However, the fundamental mechanisms that lead to macroscopic solution properties, as above mentioned, are complex and not fully understood, yet. Established analytical methods for assessing the colloidal stability, i.e. the ability of a native protein to remain dispersed in solution, are restricted to dilute conditions and provide parameters such as the second osmotic virial coefficient, B22, and the diffusion interaction coefficient, kD. These parameters are routinely applied for qualitative estimations and identifications of proteins with challenging solution behaviours, such as high viscosities and aggregation, although the assays are prepared for low protein concentration conditions, typically between 0.1 and 20 mg/ml ("ideal" solution conditions). Quantitative analysis of samples of high protein concentration is difficult and it is hard to obtain information about the driving forces of such solution properties and corresponding protein-protein self-interactions. An advantage of using specific spectroscopic methods is the potential of directly analysing highly concentrated protein solutions at different solution conditions. This allows for collecting/gaining valuable information about the fundamental mechanisms of solution properties of the high protein concentration regime. In addition, the derived parameters might be more predictive as compared to the parameters originating from assays which are optimized for the low protein concentration range. The provided information includes structural data, molecular dynamics at various timescales and protein-solvent interactions, which can be obtained at molecular resolution. Herein, we provide an overview about spectroscopic techniques for analysing the origins of macroscopic solution behaviours in general, with a specific focus on pharmaceutically relevant high protein concentration and formulation conditions.
Collapse
Affiliation(s)
- Jacob Blaffert
- Institute of Chemistry, Martin Luther University Halle-Wittenberg, Von-Danckelmann-Platz 4, 06120, Halle/Saale, Germany
| | - Haleh Hashemi Haeri
- Institute of Chemistry, Martin Luther University Halle-Wittenberg, Von-Danckelmann-Platz 4, 06120, Halle/Saale, Germany
| | - Michaela Blech
- Boehringer Ingelheim Pharma GmbH & Co. KG, Protein Science, Birkerndorfer Str. 65, 88397, Biberach/Riß, Germany
| | - Dariush Hinderberger
- Institute of Chemistry, Martin Luther University Halle-Wittenberg, Von-Danckelmann-Platz 4, 06120, Halle/Saale, Germany
| | - Patrick Garidel
- Institute of Chemistry, Martin Luther University Halle-Wittenberg, Von-Danckelmann-Platz 4, 06120, Halle/Saale, Germany; Boehringer Ingelheim Pharma GmbH & Co. KG, Protein Science, Birkerndorfer Str. 65, 88397, Biberach/Riß, Germany.
| |
Collapse
|
15
|
Manning MC, Liu J, Li T, Holcomb RE. Rational Design of Liquid Formulations of Proteins. THERAPEUTIC PROTEINS AND PEPTIDES 2018; 112:1-59. [DOI: 10.1016/bs.apcsb.2018.01.005] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
16
|
Zbacnik TJ, Holcomb RE, Katayama DS, Murphy BM, Payne RW, Coccaro RC, Evans GJ, Matsuura JE, Henry CS, Manning MC. Role of Buffers in Protein Formulations. J Pharm Sci 2016; 106:713-733. [PMID: 27894967 DOI: 10.1016/j.xphs.2016.11.014] [Citation(s) in RCA: 117] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Revised: 10/25/2016] [Accepted: 11/17/2016] [Indexed: 12/19/2022]
Abstract
Buffers comprise an integral component of protein formulations. Not only do they function to regulate shifts in pH, they also can stabilize proteins by a variety of mechanisms. The ability of buffers to stabilize therapeutic proteins whether in liquid formulations, frozen solutions, or the solid state is highlighted in this review. Addition of buffers can result in increased conformational stability of proteins, whether by ligand binding or by an excluded solute mechanism. In addition, they can alter the colloidal stability of proteins and modulate interfacial damage. Buffers can also lead to destabilization of proteins, and the stability of buffers themselves is presented. Furthermore, the potential safety and toxicity issues of buffers are discussed, with a special emphasis on the influence of buffers on the perceived pain upon injection. Finally, the interaction of buffers with other excipients is examined.
Collapse
Affiliation(s)
| | - Ryan E Holcomb
- LegacyBioDesign LLC, Johnstown, Colorado 80534; Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523
| | - Derrick S Katayama
- LegacyBioDesign LLC, Johnstown, Colorado 80534; Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523
| | - Brian M Murphy
- LegacyBioDesign LLC, Johnstown, Colorado 80534; Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523
| | - Robert W Payne
- LegacyBioDesign LLC, Johnstown, Colorado 80534; Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523
| | | | | | | | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523
| | - Mark Cornell Manning
- LegacyBioDesign LLC, Johnstown, Colorado 80534; Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523.
| |
Collapse
|
17
|
Gross J, Sayle S, Karow AR, Bakowsky U, Garidel P. Nanoparticle tracking analysis of particle size and concentration detection in suspensions of polymer and protein samples: Influence of experimental and data evaluation parameters. Eur J Pharm Biopharm 2016; 104:30-41. [PMID: 27108267 DOI: 10.1016/j.ejpb.2016.04.013] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2015] [Revised: 04/16/2016] [Accepted: 04/18/2016] [Indexed: 10/21/2022]
Abstract
Nanoparticle Tracking Analysis (NTA) is an emerging technique for detecting simultaneously sub-micron particle size distributions and particle concentrations of a sample. This study deals with the performance evaluation for the detection and characterisation of various particles by NTA. Our investigation focusses on the NTA measurement parameter set-ups, as will be shown in this study, are very crucial parameters to correctly analyse and interpret the data. In order to achieve this, we used (i) polystyrene standard particles as well as (ii) protein particles. We show the highly precise and reproducible detection of particle size and concentration in monodisperse polystyrene particle systems, under specified and constant parameter settings. On the other hand, our results exemplify potential risks and errors while setting inadequate parameters with regards to the results and thus interpretation thereof. In particular changes of the parameters, camera level (CL) and detection threshold (DT), led to significant changes in the determined particle concentration. We propose defined and specified "optimal" camera levels for monodisperse particle suspension characterisations in the size range of 20-1000nm. We illustrate that the results of polydisperse polystyrene standard particle solution measurements, highly depend on the used parameter settings, which are rarely published with the data. Changes in these settings led to the "appearance" or "disappearance" of particle populations ("peaks") for polydisperse systems. Thus, a correct evaluation of the particle size populations in the sample becomes very challenging. For the use of NTA in biopharmaceutical analysis, proteinaceous samples were investigated. We analysed protein particle suspensions and compared unstressed and stressed (formation of aggregates) protein samples similar to polystyrene particle analysis. We also studied these samples in two different measuring modes (general capture mode and live monitoring mode) that the commercially available analysis software is offering. Our results stated the live monitoring mode as more suitable for protein samples, as the results were more reproducible and less operator-depending. In conclusion, NTA is a potential technique and unique in quantitative evaluation of particle suspensions in the subvisible size range, especially for monodisperse suspensions. We strongly urge on not underestimating the influence of the measuring parameters on the obtained results, which should be presented with the data in order to better judge and interpret the NTA results.
Collapse
Affiliation(s)
- Julia Gross
- Philipps - University Marburg, Institute of Pharmaceutical Technology and Biopharmacy, D-35032 Marburg, Germany
| | - Sabrina Sayle
- Boehringer Ingelheim Pharma GmbH & Co. KG, Biopharmaceuticals, Protein Science, D-88397 Biberach an der Riss, Germany
| | - Anne R Karow
- Boehringer Ingelheim Pharma GmbH & Co. KG, Biopharmaceuticals, Protein Science, D-88397 Biberach an der Riss, Germany
| | - Udo Bakowsky
- Philipps - University Marburg, Institute of Pharmaceutical Technology and Biopharmacy, D-35032 Marburg, Germany
| | - Patrick Garidel
- Boehringer Ingelheim Pharma GmbH & Co. KG, Biopharmaceuticals, Protein Science, D-88397 Biberach an der Riss, Germany.
| |
Collapse
|
18
|
Quigley A, Williams DR. The second virial coefficient as a predictor of protein aggregation propensity: A self-interaction chromatography study. Eur J Pharm Biopharm 2015; 96:282-90. [PMID: 26259782 PMCID: PMC4644993 DOI: 10.1016/j.ejpb.2015.07.025] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 07/26/2015] [Accepted: 07/27/2015] [Indexed: 11/30/2022]
Abstract
The second osmotic virial coefficients (b2) of four proteins – lysozyme, recombinant human lactoferrin, concanavalin A and catalase were measured by self-interaction chromatography (SIC) in solutions of varying salt type, concentration and pH. Protein aggregate sizes based on the initial hydrodynamic radius of the protein solution species present were measured using dynamic light scattering, and the relationship between b2 and protein aggregate size was studied. A linear correlation was established between b2 values and protein aggregate hydrodynamic size for all proteins, and for almost all solution conditions. Aggregate sizes of <∼10 nm, indicative of non-aggregated protein systems, were consistently observed to have b2 values >0. The observed b2 trends as a function of solution conditions were very much protein dependent, with notable trends including the existence of attractive interactions (negative b2 values) at low ionic strengths for catalase and concanavalin A, and the highly positive b2 values observed for lactoferrin over a wide range of solution conditions, reflecting lactoferrin’s innately high stability. It is concluded that the quantification of protein–protein interactions using SIC based b2 data is a potentially valuable screening tool for predicting protein aggregation propensity.
Collapse
Affiliation(s)
- A Quigley
- Surfaces and Particle Engineering Laboratory, Department of Chemical Engineering, Imperial College London, London SW7 2BY, UK
| | - D R Williams
- Surfaces and Particle Engineering Laboratory, Department of Chemical Engineering, Imperial College London, London SW7 2BY, UK.
| |
Collapse
|
19
|
Garidel P, Blume A, Wagner M. Prediction of colloidal stability of high concentration protein formulations. Pharm Dev Technol 2014; 20:367-74. [DOI: 10.3109/10837450.2013.871032] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
20
|
Blanco MA, Sahin E, Robinson AS, Roberts CJ. Coarse-grained model for colloidal protein interactions, B(22), and protein cluster formation. J Phys Chem B 2013; 117:16013-28. [PMID: 24289039 DOI: 10.1021/jp409300j] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Reversible protein cluster formation is an important initial step in the processes of native and non-native protein aggregation, but involves relatively long time and length scales for detailed atomistic simulations and extensive mapping of free energy landscapes. A coarse-grained (CG) model is presented to semiquantitatively characterize the thermodynamics and key configurations involved in the landscape for protein oligomerization, as well as experimental measures of interactions such as the osmotic second virial coefficient (B22). Based on earlier work (Grüenberger et al., J. Phys. Chem. B 2013, 117, 763), this CG model treats proteins as rigid bodies composed of one bead per amino acid, with each amino acid having specific parameters for its size, hydrophobicity, and charge. The net interactions are a combination of steric repulsions, short-range attractions, and screened long-range charge-charge interactions. Model parametrization was done by fitting simulation results against experimental value of B22 as a function of solution ionic strength for α-chymotrypsinogen A and γD-Crystallin (gD-Crys). The CG model is applied to characterize the pairwise interactions and dimerization of gD-Crys and the dependence on temperature, protein concentration, and ionic strength. The results illustrate that at experimentally relevant conditions where stable dimers do not form, the entropic contributions are predominant in the free-energy of protein cluster formation and colloidal protein interactions, arguing against interpretations that treat B22 primarily from energetic considerations alone. Additionally, the results suggest that electrostatic interactions help to modulate the population of the different stable configurations for protein nearest-neighbor pairs, while short-range attractions determine the relative orientations of proteins within these configurations. Finally, simulation results are combined with Principal Component Analysis to identify those amino-acids/surface patches that form interprotein contacts at conditions that favor dimerization of gD-Crys. The resulting regions agree with previously found aggregation-prone sites, as well as suggesting new ones that may be important.
Collapse
Affiliation(s)
- Marco A Blanco
- Department of Chemical and Biomolecular Engineering and Center for Molecular and Engineering Thermodynamics, University of Delaware , Newark, Delaware 19176, United States
| | | | | | | |
Collapse
|
21
|
|
22
|
Saito S, Hasegawa J, Kobayashi N, Tomitsuka T, Uchiyama S, Fukui K. Effects of ionic strength and sugars on the aggregation propensity of monoclonal antibodies: influence of colloidal and conformational stabilities. Pharm Res 2013; 30:1263-80. [PMID: 23319172 DOI: 10.1007/s11095-012-0965-4] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2012] [Accepted: 12/13/2012] [Indexed: 10/27/2022]
Abstract
PURPOSE To develop a general strategy for optimizing monoclonal antibody (MAb) formulations. METHODS Colloidal stabilities of four representative MAbs solutions were assessed based on the second virial coefficient (B 2) at 20°C and 40°C, and net charges at different NaCl concentrations, and/or in the presence of sugars. Conformational stabilities were evaluated from the unfolding temperatures. The aggregation propensities were determined at 40°C and after freeze-thawing. The electrostatic potential of antibody surfaces was simulated for the development of rational formulations. RESULTS Similar B 2 values were obtained at 20°C and 40°C, implying little dependence on temperature. B 2 correlated quantitatively with aggregation propensities at 40°C. The net charge partly correlated with colloidal stability. Salts stabilized or destabilized MAbs, depending on repulsive or attractive interactions. Sugars improved the aggregation propensity under freeze-thaw stress through improved conformational stability. Uneven and even distributions of potential surfaces were attributed to attractive and strong repulsive electrostatic interactions. CONCLUSIONS Assessment of colloidal stability at the lowest ionic strength is particularly effective for the development of formulations. If necessary, salts are added to enhance the colloidal stability. Sugars further improved aggregation propensities by enhancing conformational stability. These behaviors are rationally predictable according to the surface potentials of MAbs.
Collapse
Affiliation(s)
- Shuntaro Saito
- Analytical & Quality Evaluation Research Laboratories, Daiichi Sankyo Co., Ltd., 1-12-1, Shinomiya, Hiratsuka-shi, Kanagawa, 254-0014, Japan
| | | | | | | | | | | |
Collapse
|
23
|
Wagner M, Reiche K, Blume A, Garidel P. The electrokinetic potential of therapeutic proteins and its modulation: Impact on protein stability. Colloids Surf A Physicochem Eng Asp 2012. [DOI: 10.1016/j.colsurfa.2012.09.024] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
24
|
James S, McManus JJ. Thermal and Solution Stability of Lysozyme in the Presence of Sucrose, Glucose, and Trehalose. J Phys Chem B 2012; 116:10182-8. [DOI: 10.1021/jp303898g] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Susan James
- Department of Chemistry, National University of Ireland Maynooth, Maynooth, Co. Kildare, Ireland
| | - Jennifer J. McManus
- Department of Chemistry, National University of Ireland Maynooth, Maynooth, Co. Kildare, Ireland
| |
Collapse
|
25
|
Printz M, Kalonia DS, Friess W. Individual Second Virial Coefficient Determination of Monomer and Oligomers in Heat-Stressed Protein Samples Using Size-Exclusion Chromatography-Light Scattering. J Pharm Sci 2012; 101:363-72. [DOI: 10.1002/jps.22749] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2010] [Revised: 08/03/2011] [Accepted: 08/12/2011] [Indexed: 11/11/2022]
|
26
|
Behavior of Monoclonal Antibodies: Relation Between the Second Virial Coefficient (B 2) at Low Concentrations and Aggregation Propensity and Viscosity at High Concentrations. Pharm Res 2011; 29:397-410. [DOI: 10.1007/s11095-011-0563-x] [Citation(s) in RCA: 96] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2011] [Accepted: 08/03/2011] [Indexed: 10/17/2022]
|