1
|
Callary SA, Sharma DK, Coffey SP, Sorial RM. Continued mid-term stability of a novel cementless femoral stem design: A radiostereometric analysis study. Clin Biomech (Bristol, Avon) 2025; 126:106560. [PMID: 40424903 DOI: 10.1016/j.clinbiomech.2025.106560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2024] [Revised: 05/06/2025] [Accepted: 05/14/2025] [Indexed: 05/29/2025]
Abstract
BACKGROUND Measuring early micromotion using radiostereometric analysis is the gold standard to evaluate new implant performance. The aim of this study was to assess the continued stability of a new cementless Paragon stem at 5 years. Secondary aims were to assess patient reported outcomes and compare the continued stability between 2 and 5 year to an existing gold standard, the Corail stem. METHODS This is a brief follow-up report of a radiostereometric analysis study. Of the original 46 patients in the 2 year study, four patients were lost to follow-up, three had died, five relocated interstate and seven withdrew from the study. We prospectively reviewed 27 primary total hip arthroplasty patients who underwent radiographic examinations at 5 years for beaded radiostereometric analysis measurements of stem translational and rotation migration. FINDINGS Median subsidence of the Paragon stem at 5 years was -0.428 mm (range - 0.107 to -1.092) and the median stem subsidence between 2 and 5 years was -0.010 mm (0.115 to -0.269). When compared to the historical Corail stem stability between two and six years, the Paragon stem demonstrated similar subsidence (p = 0.09); and significantly less medial translation (p = 0.0033), anterior translation (p < 0.0001), anterior tilt (p = 0.0004) and anteversion (p = 0.015) between 2 and 5 years. The mean Oxford Hip Score improved substantially within the first year and did not decrease between 2 (44.7, SD 5.9) and 5 years (44.0, SD 8). INTERPRETATION The Paragon stem showed continued stability up to 5 years follow-up which is encouraging for the further clinical use of this new design.
Collapse
Affiliation(s)
- Stuart A Callary
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.
| | - Deepti K Sharma
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.
| | - Simon P Coffey
- Department of Orthopaedics, Nepean Hospital, Penrith, New South Wales, Australia
| | - Rami M Sorial
- Department of Orthopaedics, Nepean Hospital, Penrith, New South Wales, Australia
| |
Collapse
|
2
|
Blum P, Neugebauer J, Keiler A, Putzer D, Watrinet J, Regenbogen S, Dammerer D. Mid-Term Migration Pattern of a Cemented Collared Anatomical Stem-A Retrospective Study Using EBRA-FCA. J Clin Med 2024; 13:5187. [PMID: 39274400 PMCID: PMC11396155 DOI: 10.3390/jcm13175187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 08/16/2024] [Accepted: 08/19/2024] [Indexed: 09/16/2024] Open
Abstract
Background: Aseptic loosening is one of the leading causes of stem revision. Einzel Bild Röntgen Analyse-Femoral Component Analysis allows for the detection of distal stem migration, which is used as a predictive factor for implant longevity. This study aims to demonstrate the migration behavior of a cemented collared anatomical stem. Methods: This study retrospectively examined all patients who received a cemented Lubinus SP II stem (Waldemar Link, Hamburg, Germany) between 2003 and 2019. We used the EBRA-FCA software (University of Innsbruck, Austria) to determine the migration patterns and thoroughly examined the patients' medical histories. In addition, the potential influence of femoral configuration and BMI on the migration behavior was assessed. Results: This study included 61 patients (48 females and 13 males) with a total of 61 stems that met our inclusion criteria. The mean age at surgery was 76 years (ranging from 30 to 93 years). According to EBRA-FCA migration analysis, a median subsidence of 0.7 mm was observed at 24 months and at the final follow-up (median 78 months). Distal stem migration was significantly higher at the 6-month time point in patients with Dorr type A femurs compared to Dorr type B femurs (p = 0.016). Body mass index (BMI) had no significant effect on stem migration. Conclusions: The measured subsidence of the Lubinus SP 2 stem using EBRA-FCA was below established thresholds, indicating excellent long-term outcomes. Although there was significantly increased subsidence in Dorr type A femurs during the initial 6 months, thereafter, no statistically significant difference was observed compared to Dorr type B femurs.
Collapse
Affiliation(s)
- Philipp Blum
- Department of Trauma Surgery, BG Trauma Center Murnau, 82418 Murnau, Germany
| | - Johannes Neugebauer
- Department of Orthopaedics and Traumatology, Krems University Hospital, 3500 Krems, Austria
- Karl Landsteiner Private University for Health Sciences, 3500 Krems, Austria
| | - Alexander Keiler
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | - David Putzer
- Department of Experimental Orthopaedics, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | - Julius Watrinet
- Department of Orthopaedic Sports Medicine, Technical University of Munich, 81675 Munich, Germany
| | - Stephan Regenbogen
- Department of Traumatology, BG Trauma Center Ludwigshafen, University of Heidelberg, 67071 Ludwigshafen, Germany
| | - Dietmar Dammerer
- Department of Orthopaedics and Traumatology, Krems University Hospital, 3500 Krems, Austria
- Karl Landsteiner Private University for Health Sciences, 3500 Krems, Austria
| |
Collapse
|
3
|
Migliorini F, Maffulli N, Pilone M, Velaj E, Hofmann UK, Bell A. Demographic characteristics influencing the stem subsidence in total hip arthroplasty: an imaging study. Arch Orthop Trauma Surg 2024; 144:887-894. [PMID: 37770626 PMCID: PMC10822810 DOI: 10.1007/s00402-023-05054-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 09/02/2023] [Indexed: 09/30/2023]
Abstract
INTRODUCTION The present study evaluated whether patient demographic characteristics influence the subsidence of the stem in total hip arthroplasty (THA). The following characteristics were evaluated: age, height, weight, and sex. The association between the time elapsed from the THA implantation and the amount of stem subsidence was also investigated. METHODS The records of patients who underwent THA in the period between 2016 and 2023 were accessed. All patients underwent two-staged bilateral THA using cementless DePuy collarless Corail (DePuy Synthes, Raynham, MA, USA) stems. The following parameters were measured and compared to assess stem subsidence: distance from the proximal femur at the stem bone interface and the medial apex of the regular triangle built within the trochanter minor (point A); distance from the medial apex of the regular triangle built within the trochanter minor and the distal portion of the femoral stem (point B). RESULTS Overall, 294 patients were included. 62% (182 of 294 patients) were women. 45% (134 of 296 THAs) were on the right side. The mean age was 64.9 ± 10.4 years. The mean BMI was 28.3 ± 5.1 kg/m2. The mean length of the follow-up was 14.4 ± 11.0 months. The mean subsidence in point A was 2.1 mm (P < 0.0001), and that in point B was 3.1 mm (P < 0.0001). There was evidence of a weak positive association between patient weight (P < 0.0001), age (P = 0.03), follow-up (P = 0.002) and the amount of stem subsidence. Patient height did not demonstrate any association with the amount of stem subsidence (P = 0.07). There was no difference in stem subsidence between women and men (P = 0.9). CONCLUSION Stem subsidence in THA using cementless DePuy collarless Corail implants is approximately 2.6 mm after 14.4 months. Greater patient weight, age, and longer time elapsed from THA implantation were associated with greater stem subsidence. Patient height and sex did not demonstrate any influence on the amount of stem subsidence. These results must be considered in light of the limitations of the present study.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany.
- Department of Orthopaedics and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of Paracelsus Medical University (PMU), 39100 Bolzano, Italy.
| | - Nicola Maffulli
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- School of Pharmacy and Bioengineering, Keele University School of Medicine, Thornburrow Drive, Stoke On Trent, England
- Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, Queen Mary University of London, 275 Bancroft Road, London, E1 4DG, England
| | - Marco Pilone
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Erlis Velaj
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany
| | - Ulf Krister Hofmann
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany
| | - Andreas Bell
- Department of Orthopedics, Eifelklinik St. Brigida, 52152, Simmerath, Germany
| |
Collapse
|
4
|
Jørgensen PB, Jakobsen SS, Vainorius D, Homilius M, Hansen TB, Stilling M. Less early subsidence of cemented Exeter short stems compared with cemented Exeter standard stems in Dorr type A femurs. Bone Jt Open 2023; 4:507-515. [PMID: 37407021 PMCID: PMC10322230 DOI: 10.1302/2633-1462.47.bjo-2023-0008.r1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/07/2023] Open
Abstract
Aims The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems. Methods In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up. Results At three months, subsidence of the short stem -0.87 mm (95% confidence interval (CI) -1.07 to -0.67) was lower compared to the standard stem -1.59 mm (95% CI -1.82 to -1.36; p < 0.001). Both stems continued a similar pattern of subsidence until five-year follow-up. At five-year follow-up, the short stem had subsided mean -1.67 mm (95% CI -1.98 to -1.36) compared to mean -2.67 mm (95% CI -3.03 to -2.32) for the standard stem (p < 0.001). Subsidence was not influenced by preoperative bone quality (osteopenia vs normal) or cement mantle thickness. Conclusion The standard Exeter stem had more early subsidence compared with the short Exeter stem in patients with Dorr type A femora, but thereafter a similar migration pattern of subsidence until minimum five years follow-up. Both the standard and the short Exeter stems subside. The standard stem subsides more compared to the short stem in Dorr type A femurs. Subsidence of the Exeter stems was not affected by cement mantle thickness.
Collapse
Affiliation(s)
- Peter B. Jørgensen
- AutoRSA Reseach Group Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Stig S. Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Dovydas Vainorius
- Department of Orthopaedics, Gødstrup Regional Hospital, Herning, Denmark
| | - Morten Homilius
- Department of Orthopaedics, Gødstrup Regional Hospital, Herning, Denmark
| | - Torben B. Hansen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
- Department of Orthopaedics, Gødstrup Regional Hospital, Herning, Denmark
| | - Maiken Stilling
- AutoRSA Reseach Group Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
5
|
Faraj S, de Windt TS, van Hooff ML, van Hellemondt GG, Spruit M. Custom-made acetabular revision arthroplasty for pelvic discontinuity: Can we handle the challenge? : a prospective cohort study. Bone Jt Open 2023; 4:53-61. [PMID: 36718581 PMCID: PMC10011926 DOI: 10.1302/2633-1462.42.bjo-2022-0159.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
AIMS The aim of this study was to assess the clinical and radiological results of patients who were revised using a custom-made triflange acetabular component (CTAC) for component loosening and pelvic discontinuity (PD) after previous total hip arthroplasty (THA). METHODS Data were extracted from a single centre prospective database of patients with PD who were treated with a CTAC. Patients were included if they had a follow-up of two years. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance and clinical relevance. RESULTS A total of 18 females with 22 CTACs who had a mean age of 73.5 years (SD 7.7) were included. A significant improvement was found in HOOS (p < 0.0001), mOHS (p < 0.0001), EQ-5D-3L utility (p = 0.003), EQ-5D-3L NRS (p = 0.013), VAS pain rest (p = 0.008), and VAS pain activity (p < 0.0001) between baseline and final follow-up. Minimal clinically important improvement in mOHS and the HOOS Physical Function Short Form (HOOS-PS) was observed in 16 patients (73%) and 14 patients (64%), respectively. Definite healing of the PD was observed in 19 hips (86%). Complications included six cases with broken screws (27%), four cases (18%) with bony fractures, and one case (4.5%) with sciatic nerve paresthesia. One patient with concurrent bilateral PD had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage. CONCLUSION CTAC in patients with THA acetabular loosening and PD can result in stable constructs and significant improvement in functioning and health-related quality of life at two years' follow-up. Further follow-up is necessary to determine the mid- to long-term outcome.Cite this article: Bone Jt Open 2023;4(2):53-61.
Collapse
Affiliation(s)
- Sayf Faraj
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, the Netherlands
| | - Tommy S de Windt
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, the Netherlands
| | - Miranda L van Hooff
- Department of Research, Sint Maartenskliniek, Nijmegen, the Netherlands.,Department of Orthopedic Surgery, Radboud University Medical Centre, Nijmegen, the Netherlands
| | | | - Maarten Spruit
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, the Netherlands
| |
Collapse
|
6
|
Vind TD, Jørgensen PB, Vainorius D, Jakobsen SS, Søballe K, Stilling M. Migration pattern of cemented Exeter short stem in Dorr type A femurs. A prospective radiostereometry study with 2-year follow-up. Arch Orthop Trauma Surg 2023; 143:1071-1080. [PMID: 35113240 DOI: 10.1007/s00402-021-04307-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 12/04/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION The Exeter short stem (ESS) is 25 mm shorter than the standard length v40 Exeter stem (Stryker) and intended for a narrow femoral diaphysis. The purpose of the study was to evaluate the migration pattern of the cemented ESS. MATERIAL AND METHOD In a prospective single-center cohort study, 23 patients (21 female) mean age 78 (range 70-89) with hip osteoarthritis and Dorr Type A femurs were included. Preoperative DXA was used to group patients into normal (> - 1) and low (< - 1) T-score. Components were the collarless polished double-tapered Exeter short stem type N°1 L125. Patients were followed for 2 years with model-based RSA (stem migration), regular hip radiographs (stem position and cementation quality), Oxford Hip Score (OHS) and VAS pain. RESULTS At 2-year follow-up, the stems subsided 1.48 mm (CI 95% 1.69; 1.26) and retroverted 0.45° (CI 95% 0.01; 0.88). From 12 to 24 months, stem subsidence was 0.18 mm (CI 95% 0.1; 0.25) (p = 0.001) and retroversion was - 0.04° (CI 95% - 0.27; 0.18) (p = 0.70). T-score and stem subsidence correlated (rho = 0.48; p = 0.025) and patients with normal T-score (n = 7) had 0.42 mm (CI 95% - 0.01; 0.85) less subsidence as compared to patients with low T-score (n = 15) (p = 0.054). Stems in varus position (n = 9) subsided 1.7 mm (CI 95% 1.35; 2.05) compared to 1.33 mm (CI 95% 1.05; 1.60) for stems in neutral position (n = 13) (p = 0.07). Postoperative cementation quality did not influence 2-year stem migration. OHS improved to 40.7 (CI 95% 36.8; 44.7) and VAS pain at rest and activity decreased to 5 mm and 10 mm, respectively (p < 0.001). CONCLUSION The 2-year migration pattern of the cemented ESS was similar to reports for the cemented standard length Exeter stem. Low preoperative T-score and varus stem-position showed a tendency for higher stem migration and should be studied as risk factors for failure in larger studies of cemented polished stems.
Collapse
Affiliation(s)
- Tobias Dahl Vind
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus, Denmark.
- Aarhus University, Aarhus, Denmark.
| | - Peter Bo Jørgensen
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus, Denmark
| | - Dovydas Vainorius
- Hospital Unit West, University Clinic for Hand, Hip and Knee Surgery, Lægårdvej 12, 7500, Holstebro, Denmark
| | - Stig Storgaard Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus, Denmark
| | - Kjeld Søballe
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus, Denmark
| |
Collapse
|
7
|
Sevaldsen K, Schnell Husby O, Lian ØB, Farran KM, Schnell Husby V. Is the French Paradox cementing philosophy superior to the standard cementing? A randomized controlled radiostereometric trial and comparative analysis. Bone Joint J 2022; 104-B:19-26. [PMID: 34969272 PMCID: PMC8779947 DOI: 10.1302/0301-620x.104b1.bjj-2021-0325.r2] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Aims Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. Methods In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis. Results Results from mixed model analyses revealed a lower mean retroversion for line-to-line (0.72° (95% confidence interval (CI) 0.38° to 1.07°; p < 0.001), but no significant differences in subsidence between the techniques (-0.15 mm (95% CI -0.53 to 0.227; p = 0.429) at 24 months. Radiolucent lines measuring < 2 mm wide were found in three and five arthroplasties cemented by the standard and line-to-line method, respectively. Conclusion The cemented Corail stem with a force-closed design seems to settle earlier and better with the line-to-line cementing method, although for subsidence the difference was not significant. However, the lower rate of migration into retroversion may reduce the wear and cement deformation, contributing to good long-term fixation and implant survival. Cite this article: Bone Joint J 2022;104-B(1):19–26.
Collapse
Affiliation(s)
- Kirsti Sevaldsen
- Department of Orthopaedic Surgery, Kristiansund Hospital, Kristiansund, Norway.,Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Trondheim, Norway
| | - Otto Schnell Husby
- Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Trondheim, Norway.,Clinic of Orthopaedics, Rheumatology and Dermatology, Department of Orthopaedic Surgery, St. Olav's University Hospital, Trondheim, Norway
| | - Øystein Bjerkestrand Lian
- Department of Orthopaedic Surgery, Kristiansund Hospital, Kristiansund, Norway.,Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Trondheim, Norway
| | | | - Vigdis Schnell Husby
- Clinic of Orthopaedics, Rheumatology and Dermatology, Department of Orthopaedic Surgery, St. Olav's University Hospital, Trondheim, Norway.,Department of Health Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Ålesund, Norway
| |
Collapse
|
8
|
Mjöberg B. Hip prosthetic loosening: A very personal review. World J Orthop 2021; 12:629-639. [PMID: 34631447 PMCID: PMC8472441 DOI: 10.5312/wjo.v12.i9.629] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 05/03/2021] [Accepted: 08/03/2021] [Indexed: 02/06/2023] Open
Abstract
Hip prosthetic loosening is often difficult to detect at an early stage, and there has been uncertainty for a long time as to when the loosening occurs and thus to the basic causes. By comparing different diagnostic methods, we found that loosening is best defined as prosthetic migration and measured by radiostereometric analysis. Convincing evidence indicates that poor interlock, poor bone quality, and resorption of a necrotic bone bed may initiate loosening during or shortly after surgery; this forms the basis of the theory of early loosening. Biomechanical factors do affect the subsequent progression of loosening, which may increase subclinically during a long period of time. Eventually, the loosening may be detected on standard radiographs and may be interpreted as late loosening but should to be interpreted as late detection of loosening. The theory of early loosening explains the rapid early migration, the development of periprosthetic osteolysis and granulomas, the causality between wear and loosening, and largely the epidemiology of clinical failure of hip prostheses. Aspects discussed are definition of loosening, the pattern of early migration, the choice of migration threshold, the current understanding of loosening, a less exothermic bone cement, cemented taper-slip stems, a new exciting computed tomography-based technique for simpler implant migration studies, and research suggestions.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopedics, Lund University, Lund SE-221 00, Sweden
| |
Collapse
|
9
|
Jain S, Mohrir G, Townsend O, Lamb JN, Palan J, Aderinto J, Pandit H. Reliability and validity of the Unified Classification System for postoperative periprosthetic femoral fractures around cemented polished taper-slip stems. Bone Joint J 2021; 103-B:1339-1344. [PMID: 34334039 DOI: 10.1302/0301-620x.103b8.bjj-2021-0021.r1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
AIMS This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. METHODS Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss' kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs. RESULTS Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement. CONCLUSION This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339-1344.
Collapse
Affiliation(s)
- Sameer Jain
- University of Leeds, Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital, Leeds, UK.,Chapel Allerton Hospital, Leeds, UK
| | | | - Oliver Townsend
- Southampton University Hospitals NHS Trust, Southampton, Southampton, UK
| | - Jonathan N Lamb
- University of Leeds, Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital, Leeds, UK.,Chapel Allerton Hospital, Leeds, UK
| | - Jeya Palan
- University of Leeds, Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital, Leeds, UK.,Chapel Allerton Hospital, Leeds, UK
| | | | - Hemant Pandit
- University of Leeds, Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital, Leeds, UK.,Chapel Allerton Hospital, Leeds, UK
| |
Collapse
|
10
|
The intraoperative use of a calliper predicts leg length and offset after total hip arthroplasty. Component subsidence influences the leg length. J Orthop Surg Res 2021; 16:424. [PMID: 34217347 PMCID: PMC8254249 DOI: 10.1186/s13018-021-02559-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 06/15/2021] [Indexed: 11/18/2022] Open
Abstract
Background The purpose of total hip arthroplasty (THA) post-surgery and proper physiotherapy is positive recovery for the patient. Consideration is given to hip replacement biomechanics by ensuring no discrepancies in limb length (LL) and a stable prosthesis. Therefore, the patient must have proper preoperative planning and communication and a clear understanding of what to expect. Methods A prospective series of 59 THA operated by a single surgeon via Hardinge approach was studied, using an intraoperative calliper (CAL) to predict the change of LL and offset. We compared the results of the intraoperative changes before and after THA implantation with the reference of these values on anteroposterior x-ray pelvis. The importance of leg length balance and a good offset restoration is questioned, and the effect of component subsidence on leg length is considered. Results The average preoperative leg length discrepancy was −6.0 mm, postoperatively +3.6 mm. There was a strong correlation between the CAL measurements and the values on the x-ray (LL, r=0.873, p<0.01; offset, r=0.542, p<0.01). Reliability is better for limb length than for offset. These results are comparable within the literature and the statistical results from other studies reviewed. In addition, we evaluate the importance of subsidence of the prosthesis components for long-term results. Conclusion The intraoperative use of CAL gives excellent results in predicting the final LL and offset after THA. Considering subsidence of prosthesis components, a target zone around +5 mm might be more suitable for leg length directly postoperatively. Moreover, surgeons must discuss the topic of leg length discrepancy (LLD) intensively with the patient pre-operatively. Level of evidence Level 4, prospective cohort study
Collapse
|
11
|
Jain S, Lamb J, Townsend O, Scott CEH, Kendrick B, Middleton R, Jones SA, Board T, West R, Pandit H. Risk factors influencing fracture characteristics in postoperative periprosthetic femoral fractures around cemented stems in total hip arthroplasty : a multicentre observational cohort study on 584 fractures. Bone Jt Open 2021; 2:466-475. [PMID: 34233455 PMCID: PMC8325979 DOI: 10.1302/2633-1462.27.bjo-2021-0027.r1] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Aims This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type. Results A total of 584 cases were included. Median age was 79.1 years (interquartile range 72.0 to 86.0), 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The most common AO/OTA type was spiral (352, 60.3%). Metaphyseal split fractures occurred only with PTS stems with an incidence of 10.1%. Male sex was associated with a five-fold reduction in odds of a type C fracture (OR 0.22 (95% CI 0.12 to 0.41); p < 0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51 (95% CI 3.72 to 24.34); p < 0.001) and wedge fracture (OR 3.72 (95% CI 1.16 to 11.95); p = 0.027) compared to PTS stems. Both UCS grade and AO/OTA type differed significantly (p < 0.001 and p = 0.001, respectively) between the revision and fixation groups but a similar proportion of B1 fractures underwent revision compared to fixation (45.3% vs 50.6%). Conclusion The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems have higher odds of bending type fractures (transverse and wedge) compared to PTS stems. There is considerable variation in practice when treating B1 fractures around cemented stems. Cite this article: Bone Jt Open 2021;2(7):466–475.
Collapse
Affiliation(s)
- Sameer Jain
- University of Leeds, Leeds, UK.,Chapel Allerton Hospital, Leeds, UK
| | - Jonathan Lamb
- University of Leeds, Leeds, UK.,Chapel Allerton Hospital, Leeds, UK
| | | | | | - Ben Kendrick
- Nuffield Orthopaedic Centre, Oxford University Hospitals, Oxford, UK
| | | | | | | | | | - Hemant Pandit
- Chapel Allerton Hospital, Leeds, UK.,University of Leeds, Leeds, UK
| |
Collapse
|
12
|
Baryeh K, Mendis J, Sochart DH. Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review. EFORT Open Rev 2021; 6:331-342. [PMID: 34150327 PMCID: PMC8183154 DOI: 10.1302/2058-5241.6.200086] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The literature was reviewed to establish the levels of stem subsidence for both double and triple-tapered implants in order to determine whether there were any differences in subsidence levels with regard to the methods of measurement, the magnitude and rate of subsidence and clinical outcomes. All studies reporting subsidence of polished taper-slip stems were identified. Patient demographics, implant design, radiological findings, details of surgical technique, methods of measurement and levels of subsidence were collected to investigate which factors were related to increased subsidence. Following application of inclusion and exclusion criteria, 28 papers of relevance were identified. The studies initially recruited 3090 hips with 2099 being available for radiological analysis at final follow-up. Patient age averaged 68 years (42–70), 60.4% were female and the average body mass index (BMI) was 27.4 kg/m2 (24.1–29.2). Mean subsidence at one, two, five and 10 years was 0.97 mm, 1.07 mm, 1.47 mm and 1.61 mm respectively. Although double-tapered stems subsided more than triple-tapered stems at all time points this was not statistically significant (p > 0.05), nor was the method of measurement used (p > 0.05). We report the levels of subsidence at which clinical outcomes and survivorship remain excellent, but based on the literature it was not possible to determine a threshold of subsidence beyond which failure was more likely. There were relatively few studies of triple-tapered stems, but given that there were no statistically significant differences, the levels presented in this review can be applied to both double and triple-tapered designs.
Cite this article: EFORT Open Rev 2021;6:331-342. DOI: 10.1302/2058-5241.6.200086
Collapse
Affiliation(s)
- Kwaku Baryeh
- The Academic Surgical Unit, South West London Elective Orthopaedic Centre, UK
| | | | - David H Sochart
- The Academic Surgical Unit, South West London Elective Orthopaedic Centre, UK
| |
Collapse
|
13
|
Steiner DK, Drivsholm NS, Buchardt STE, Laursen M. The influence of migration of the exeter V40 stem on patient reported outcome measures: a 2-year follow-up of 112 total hip arthroplasties using radiostereometric analysis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2021; 32:167-174. [PMID: 33763771 DOI: 10.1007/s00590-021-02937-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 03/10/2021] [Indexed: 11/28/2022]
Abstract
PURPOSE The cemented Exeter V40 stem is known to migrate distally. Several previous studies have reported on the extent of stem migration and its influence on clinical outcome. However, no studies have investigated the influence of stem migration on Patient Reported Outcome Measures (PROM). METHODS One hundred and twelve total hip arthroplasties (THA) were included in a 2-year follow-up using Radiostereometric Analysis (RSA). Patients were evaluated using the Oxford Hip Score (OHS) and EQ-5D-3L PROMs. The purpose of this study was to assess the influence of stem migration, measured by Maximum Total Point Motion (MTPM), on the 2-year postoperative score (OHS and EQ-5D). Furthermore, the influence of pre-operative PROM, age, gender, acetabular component and BMI was associated with the 2-year postoperative OHS and EQ-5D scores. RESULTS MTPM was a non-significant predictor of the 2-year postoperative OHS (regression coefficient (B) = - 2.38 (CI - 5.44; .69)) and of the 2-year postoperative EQ-5D (B = - .01 (CI - .04; .02)). The only significant predictor of the 2-year postoperative OHS and 2-year postoperative EQ-5D was gender (B = 8.71 (CI 3.52; 13.90)) and (B = .13 (CI .07; .18)), respectively. CONCLUSION Stem migration did not significantly influence PROMs at 2 years post-operatively. Using a patient-focused approach, our results seem to corroborate results reported by previous studies, showing that slow migration of the Exeter V40 stem does not seem to influence the clinical outcome.
Collapse
Affiliation(s)
- Daniel K Steiner
- Department of Orthopaedic Surgery, Aalborg University Hospital, Farsoe, Denmark. .,Department of Orthopaedic Surgery, School of Medicine, Aalborg University, Aalborg, Denmark.
| | - Nikolaj S Drivsholm
- Department of Orthopaedic Surgery, Aalborg University Hospital, Farsoe, Denmark
| | | | - Mogens Laursen
- Department of Orthopaedic Surgery, Aalborg University Hospital, Farsoe, Denmark
| |
Collapse
|
14
|
Richardson CG, Laende EK, Gross M, Dunbar MJ. Prospective clinical study using radiostereometric analysis (RSA) to evaluate fixation of a modular cemented polished femoral stem. Hip Int 2021; 31:191-195. [PMID: 31615281 DOI: 10.1177/1120700019881429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The long-term clinical success of cemented polished tapered femoral components has been demonstrated in prospective as well as registry studies. This stem design type has also been well studied with radiostereometric analysis (RSA) and provides a standard to evaluate alternative designs of polished tapered cemented femoral components. This prospective study evaluates the subsidence of a polished cemented stem with a modular neck design utilising RSA. METHODS 26 patients were prospectively enrolled in the study and 23 were available for RSA analysis at 2 years. RESULTS The average subsidence of the femoral implant was 1.1 mm (SD 0.4 mm) at 2 years post operation. There were no revisions in this group, specifically no failures of the modular stem-neck design as has been seen with other implants. CONCLUSIONS The RSA subsidence pattern at 2 years of this cemented femoral stem is similar to other successful designs with long-term follow-up. The implications over time of stem neck modularity for cemented polished tapered femoral components requires further evaluation.
Collapse
Affiliation(s)
- C Glen Richardson
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Elise K Laende
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.,School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Michael Gross
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Michael J Dunbar
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.,School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
15
|
Zampelis V, Flivik G. Custom-made 3D-printed cup-cage implants for complex acetabular revisions: evaluation of pre-planned versus achieved positioning and 1-year migration data in 10 patients. Acta Orthop 2021; 92:23-28. [PMID: 32928018 PMCID: PMC7919918 DOI: 10.1080/17453674.2020.1819729] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The use of custom-made 3D-printed titanium implants for the reconstruction of large acetabular defects has been successively introduced in the last decade. In an observational cohort study we evaluated the agreement between preoperatively planned and actually achieved cup-cage position as well as 1-year follow-up migration of the cup-cage component.Patients and methods - 10 patients with Paprosky III defects underwent revision surgery using a custom-made 3D-printed cup-cage. The position of the implant on postoperative CT scan was compared with the preoperative plan and the postoperative CT scan was compared with the 1-year follow-up CT scan.Results - There was a median deviation in postoperative position versus planned in inclination of 3.6° (IQR 1.0-5.4), in anteversion of -2.8° (IQR -7.5 to 1.2), and in rotation of -1.2° (IQR -3.3 to 0.0). The median deviation in position of the center of rotation (COR) was -0.5 mm (IQR 2.9 to 0.7) in the anteroposterior (AP) plane, -0.6 mm (IQR -1.8 to -0.1) in the mediolateral (ML) plane, and 1.1 mm (IQR -1.6 to 2.8) in the superoinferior (SI) plane. The migration between postoperative and 1-year follow-up caused a mean change in inclination of 0.04° (IQR -0.06 to 0.09), in anteversion of -0.13° (IQR -0.23 to -0.06), and in rotation of 0.05° (IQR -0.46 to 1.4). The migration of COR was -0.08 mm (IQR -0.18 to -0.04) in the AP plane, 0.14 mm (IQR -0.08 to 0.22) in the ML plane, and 0.06 mm (IQR -0.02 to 0.35) in the SI plane. There was no re-revision.Interpretation - The early results show good agreement between planned and achieved cup-cage position and small measured migration values of the cup-cage component at the 1-year follow-up.
Collapse
Affiliation(s)
- Vasileios Zampelis
- Department of Orthopedics, Skane University Hospital, Clinical Sciences, Lund University, Lund, Sweden,Correspondence:
| | - Gunnar Flivik
- Department of Orthopedics, Skane University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
16
|
Yoon JY, Park CW, Park YS, Yoo JJ, Kim HJ. Total Hip Arthroplasty for Secondary Coxarthrosis in Patients with Hereditary Multiple Exostoses: Minimum 5-Year Follow-up Results and Surgical Considerations. Clin Orthop Surg 2020; 12:435-441. [PMID: 33274019 PMCID: PMC7683187 DOI: 10.4055/cios20044] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 03/25/2020] [Indexed: 11/20/2022] Open
Abstract
Background Hereditary multiple exostoses (HME) is an autosomal dominant disorder. The lesion in the proximal femoral metaphysis can bring about hip dysplasia and subsequent degenerative arthritis. Due to its rare prevalence, there have been a few case reports of total hip arthroplasty (THA) for osteoarthritis secondary to HME. The aim of this study was to report mid- to long-term outcomes of THA in HME patients and discuss special considerations that should be taken into account during surgery. Methods We retrospectively evaluated the clinical and radiological results of THA for osteoarthritis secondary to HME in 11 hips of 9 patients after a minimum follow-up of 5 years (mean, 9.9 years). There were 3 men (3 hips) and 6 women (8 hips), with a mean age of 53.6 years (range, 46.8–58 years) at the index surgery in this study. Harris hip score (HHS) was used for clinical outcome assessment, and radiologically, implant stability, radiolucent lines, liner wear, and any sign of osteolysis or implant loosening were evaluated. Postoperative complications including infection, deep vein thrombosis, and dislocations were also investigated. Results Cemented stems and cementless cups with the conventional polyethylene liner were used in bilateral hips of a single patient. In the other cases, cementless implants were used with ceramic-on-ceramic bearings. The mean HHS improved from 34.8 preoperatively to 92.5 postoperatively. Polyethylene liner wear and osteolysis were observed in 1 patient with cemented stems. Radiolucent lines were observed in 2 different cases. However, the femoral stems remained stable. There were no surgery-related complications except heterotopic ossification during follow-up. Conclusions Despite the several surgical considerations, the mid- to long-term clinical and radiological outcomes of THA in HME patients were satisfactory. The abnormal, wide mediolateral diameter of the proximal metaphysis should be considered in selecting and inserting the stem with adequate anteversion. Leg length discrepancy was also common, so teleradiographs should be obtained before surgery. Intraoperative leg length evaluation might be difficult due to the morphologic changes in the proximal femur after mass excision and individual bone length differences.
Collapse
Affiliation(s)
- Jae Youn Yoon
- Department of Orthopedic Surgery, Dongguk University Ilsan Hospital, Goyang, Korea
| | - Chan-Woo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Youn-Soo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jeong Joon Yoo
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Hee Joong Kim
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
17
|
Miyamoto S, Iida S, Suzuki C, Kawarai Y, Nakatani T, Nakamura J, Orita S, Ohtori S. Postoperative migration of the anatomical and functional anteversion angle following total hip arthroplasty with a well-fixed cemented femoral component with line-to-line implantation. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2020; 30:1067-1074. [PMID: 32314066 DOI: 10.1007/s00590-020-02671-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Accepted: 04/07/2020] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Little is known about the association between well-fixed polished tapered cemented stems (PTCS) implanted by the line-to-line technique and changes of stem migration, or the change of functional anteversion of the femur after total hip arthroplasty (THA). MATERIALS AND METHODS This retrospective study included 422 two-stage bilateral primary THAs performed using PTCS implanted by the line-to-line technique. CT scans were made on both the target side (first postoperative CT) and on the contralateral side (second postoperative CT) 1 week postoperatively. The mean follow-up was 7.8 months. CT data for each scan were transferred to 3D template software (Zed hip, Lexi, Japan). The postoperative changes of anatomical stem anteversion (ASA), functional femoral anteversion (FFA), and stem subsidence were evaluated. RESULTS A total of 20 THAs with CT scans were available on 3D template software. The ASA and the FFA had migrated - 0.68° ± 0.62° and - 5.5° ± 9.7°, respectively, over the follow-up period. A significant positive correlation was observed between the change of subsidence and ASA (r2 = 0.34, p = 0.007), between the FFA on the second postoperative CT and ASA on the first postoperative CT (r2 = 0.26, p = 0.02) and between the FFA on the second postoperative CT and FFA on the first postoperative CT (r2 = 0.52, p = 0.0003). CONCLUSION This study indicates that the change in axial rotation of a PTCS implanted by the line-to-line technique was less than that reported by other studies and the preoperative external rotation contracture was substantially improved after THA.
Collapse
Affiliation(s)
- Shuichi Miyamoto
- Matsudo City General Hospital, 993-1 Sendabori, Matsudo, Chiba, 270-2296, Japan.
| | - Satoshi Iida
- Matsudo City General Hospital, 993-1 Sendabori, Matsudo, Chiba, 270-2296, Japan
| | - Chiho Suzuki
- Matsudo City General Hospital, 993-1 Sendabori, Matsudo, Chiba, 270-2296, Japan
| | - Yuya Kawarai
- Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Chiba, 260-8677, Japan
| | - Takushi Nakatani
- Matsudo City General Hospital, 993-1 Sendabori, Matsudo, Chiba, 270-2296, Japan
| | - Junichi Nakamura
- Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Chiba, 260-8677, Japan
| | - Sumihisa Orita
- Center for Advanced Joint Function and Reconstructive Spine Surgery Graduate School of Medicine, Chiba University, 1-8-1 Inohana Chuo-ku, Chiba, 260-8670, Japan
| | - Seiji Ohtori
- Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Chiba, 260-8677, Japan
| |
Collapse
|
18
|
Cassar-Gheiti AJ, McColgan R, Kelly M, Cassar-Gheiti TM, Kenny P, Murphy CG. Current concepts and outcomes in cemented femoral stem design and cementation techniques: the argument for a new classification system. EFORT Open Rev 2020; 5:241-252. [PMID: 32377392 PMCID: PMC7202038 DOI: 10.1302/2058-5241.5.190034] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
Cemented implant fixation design principles have evolved since the 1950s, and various femoral stem designs are currently in use to provide a stable construct between the implant-cement and cement-bone interfaces.Cemented stems have classically been classified into two broad categories: taper slip or force closed, and composite beams or shaped closed designs. While these simplifications are acceptable general categories, there are other important surgical details that need to be taken into consideration such as different broaching techniques, cementing techniques and mantle thickness.With the evolution of cemented implants, the introduction of newer implants which have hybrid properties, and the use of different broaching techniques, the classification of a very heterogenous group of implants into simple binary categories becomes increasingly difficult. A more comprehensive classification system would aid in comparison of results and better understanding of the implants' biomechanics.We review these differing stem designs, their respective cementing techniques and geometries. We then propose a simple four-part classification system and summarize the long-term outcomes and international registry data for each respective type of cemented prosthesis. Cite this article: EFORT Open Rev 2020;5:241-252. DOI: 10.1302/2058-5241.5.190034.
Collapse
Affiliation(s)
| | | | - Martin Kelly
- Connolly Hospital, Orthopaedic Department, Dublin, Ireland
| | | | - Paddy Kenny
- Cappagh National Orthopaedic Hospital, Dublin, Ireland
- Connolly Hospital, Orthopaedic Department, Dublin, Ireland
| | | |
Collapse
|
19
|
New Implant Introduction in Total Hip Arthroplasty Using Radiostereometric Analysis: A Cautionary Note. J Arthroplasty 2020; 35:643-646. [PMID: 31678017 DOI: 10.1016/j.arth.2019.10.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 09/22/2019] [Accepted: 10/03/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND It has been proposed that the introduction of new hip implant technology in orthopedic surgery be conducted in a more controlled manner in order to properly ensure patient safety and the likelihood of favorable outcomes. This stepwise introduction would first require a prospective randomized study in a small cohort of patients, using radiostereometric analysis (RSA). The aim of this study is to determine if the recent literature supports the use of RSA as an early screening tool to accurately predict the long-term outcomes of cementless femoral stems. METHODS A review of the recent published literature identified 11 studies that used RSA to predict the long-term stability of a cementless femoral component. These RSA predictive data were compared to the 10-year revision rate reported in the Australian Registry or in the published literature to determine its reliability. RESULTS RSA data did not universally predict long-term stem fixation. In 2 of the 11 cases (18%), the RSA study incorrectly predicted the ability of the cementless stem to reliably osseointegrate. Of the 9 stems considered stable in the RSA studies, the 10 year registry and literature data confirmed that 6 implants had a low revision rate and were well performing. One stem has not performed well clinically and has been listed as having a higher than anticipated rate of revision in the registry. Two stems do not have sufficient follow-up. Of the 2 stems RSA predicted to do poorly, 1 is well performing at 10 years, and 1 has a high revision rate at 8 years. CONCLUSION In the stepwise introduction of new hip implants, RSA should be best considered as an adjunct tool in deciding whether or not an implant should be evaluated in a larger multicenter clinical studies, rather than the sole criterion.
Collapse
|
20
|
Critchley O, Callary S, Mercer G, Campbell D, Wilson C. Long-term migration characteristics of the Corail hydroxyapatite-coated femoral stem: a 14-year radiostereometric analysis follow-up study. Arch Orthop Trauma Surg 2020; 140:121-127. [PMID: 31655879 DOI: 10.1007/s00402-019-03291-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2019] [Indexed: 01/24/2023]
Abstract
BACKGROUND The magnitude and pattern of acceptable long-term migration of cementless femoral stems are not well understood. The Corail hydroxyapatite-coated cementless stem is a clinically successful and commonly used femoral stem with a long-term migration pattern not previously described in the literature. The aim of this study was to assess the long-term migration of the Corail hydroxyapatite-coated cementless stem using radiostereometric analysis (RSA) at 14-year follow-up, thereby establishing a benchmark acceptable long-term migration pattern for hydroxyapatite-coated cementless prostheses. MATERIALS AND METHODS A prospective cohort of 29 patients (30 hips) undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration of the Corail cementless stem. A total of 13 patients (4 males, 9 females) with mean age 82 (range 68-92) underwent repeat RSA radiographs at minimum 10 years post-operation (mean 13.9 years, range 13.3-14.4). Subsidence of the stem was measured and compared to prior measurements taken at 6 months and 1, 2, and 6 years. RESULTS None of the 13 patients have been revised. The migration at 6 months, 1 year, 2 years, and 6 years has been previously recorded. At mean 14-year follow-up, the cohort mean subsidence of the cementless stem was 0.70 mm (range - 0.06 to 3.61 mm). For each stem followed up at 6 months and 14 years, the mean subsidence over this period was 0.05 mm (range - 0.14 to 0.57 mm). There is no significant difference in mean subsidence at 6 months and 14 years (p = 0.43). CONCLUSIONS The long-term pattern of the subsidence of the Corail femoral stem has not previously been described. Subsidence occurs within the first 6 months, after which there is persistent stabilisation of the implant to 14 years. This study provides a description of a long-term acceptable migration pattern to which new hydroxyapatite-coated cementless prostheses may be compared. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Owain Critchley
- Department of Orthopaedics and Trauma Surgery, Flinders University, Adelaide, SA, Australia.,Department of Orthopaedics and Trauma, Flinders Medical Centre, Flinders Drive, Bedford Park, Adelaide, SA, 5042, Australia
| | - Stuart Callary
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia.,Centre for Orthopaedic and Trauma Research, University of Adelaide, Adelaide, SA, Australia
| | - Graham Mercer
- Department of Orthopaedics, Repatriation General Hospital, Adelaide, SA, Australia
| | - David Campbell
- Wakefield Orthopaedic Clinic, 270 Wakefield Street, Adelaide, SA, Australia
| | - Christopher Wilson
- Department of Orthopaedics and Trauma Surgery, Flinders University, Adelaide, SA, Australia. .,Department of Orthopaedics and Trauma, Flinders Medical Centre, Flinders Drive, Bedford Park, Adelaide, SA, 5042, Australia.
| |
Collapse
|
21
|
Jørgensen PB, Lamm M, Søballe K, Stilling M. Equivalent hip stem fixation by Hi-Fatigue G and Palacos R + G bone cement: a randomized radiostereometric controlled trial of 52 patients with 2 years' follow-up. Acta Orthop 2019; 90:237-242. [PMID: 30931663 PMCID: PMC6534245 DOI: 10.1080/17453674.2019.1595390] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Long-term fixation of cemented femoral stems relies on several factors including cement adhesion and fatigue. Hi-Fatigue is a newer third-generation bone cement with low-viscosity properties at room temperature, good mechanical strength, and stable bone-cement interface in a laboratory testing environment. Palacos bone cement has excellent 10-year survival and is considered gold standard. We compared stem subsidence after fixation with Hi-Fatigue and Palacos bone cements using radiostereometry. Patients and methods - In a patient-blinded randomized controlled trial, 52 patients (30 women) at mean age 76 years (71-87) with osteoarthrosis and no osteoporosis received Hi-Fatigue G or Palacos R + G cement fixation of collarless, polished, double-tapered stems (CPT). Tantalum beads were inserted in the periprosthetic bone. Supine stereoradiographs were obtained postoperatively, 3 months, 6 months, 1 year, and 2 years after surgery. Oxford Hip Score (OHS) and VAS pain were recorded preoperatively and 1 and 2 years after surgery. Cement working times and properties were registered. Results - At 2 years, mean stem subsidence of 1.12 mm (95% CI 0.96-1.29) for Hi-Fatigue and 1.19 mm (CI 1.03-1.34) for Palacos was similar. Likewise, stem version was comparable between cement groups. Mean OHS and VAS pain were similar between cement groups. Cement working times were similar between cement groups, but the mean curing time was longer for Hi-Fatigue (13.7 min) than for Palacos (11.6 min). Interpretation - We found similar and generally low migration of CPT femoral stems inserted with Hi-Fatigue and Palacos bone cement until 2 years' follow-up, which indicates a good long-term survival of polished taper femoral stems inserted with both cement types.
Collapse
Affiliation(s)
- Peter B Jørgensen
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark,Correspondence:
| | - Martin Lamm
- Department of Orthopedic Surgery, Aarhus University Hospital;;
| | - Kjeld Søballe
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark
| | - Maiken Stilling
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark
| |
Collapse
|
22
|
Madörin K, Siepen W, Manzoni I, Stoffel KK, Ilchmann T, Clauss M. Five-year prospective subsidence analysis of 100 cemented polished straight stems: A concise clinical and radiological follow-up observation. Orthop Rev (Pavia) 2019; 11:7984. [PMID: 31210913 PMCID: PMC6551455 DOI: 10.4081/or.2019.7984] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2019] [Accepted: 05/02/2019] [Indexed: 12/31/2022] Open
Abstract
Early subsidence (>1.5mm) has been shown to be an indicator for later aseptic loosening of cemented hip stems. For the cemented twinSys® stem we published excellent short-term results at 2 years. Midterm data for this stem are available from national registers (NZL, NL), however in all of these sources, clinical and radiological results are missing. Aim of our study was to analyse mid-term survival and radiological changes around the cemented twinSys® stem with special emphasis on subsidence using EBRA-FCA. We conducted a prospective clinical and radiological 5- year follow-up study of 100 consecutive hybrid total hip arthroplasties (THA) using a polished, cemented collarless straight stem (twinSys®, Mathys AG® Bettlach, Switzerland) with a cementless monobloc pressfit cup (RM pressfit®, Mathys AG® Bettlach, Switzerland). Median age at surgery was 79 (69 to 93) years. No patient was lost to follow-up. Survival rates were calculated using the Kaplan-Meier method. Clinical (Harris Hip Score [HHS]) and radiological (cementing quality, alignment, osteolysis, debonding and cortical atrophy) outcomes and an in-depth subsidence analysis using EBRA-FCA were performed. 22 patients died in the course of follow-up unrelated to surgery, 21 stems had an incomplete radiological follow-up. 2 stems were revised, both due to an infection. The survival rate for the stem at 5 years was 98.0% (95% CI 95.3-100%). The survival rate of the stem for revision due to aseptic loosening at 5 years was 100%. The HHS improved from 53 (14-86) points preoperatively to 90 (49-100) points 5 years after surgery. Osteolysis was found in 2 stems without clinical symptoms. In 49 out of 55 patients with a complete radiological follow- up, the EBRA-FCA analysis was possible and showed an average subsidence of 0.66 (95% CI 0.46 to 0.86) mm 5 years after surgery. 10 patients showed a subsidence >1 mm, 5 of which bigger than 1.5 mm. Subsidence was independent from radiological changes and cementing quality. The cemented twinSys® stem showed excellent clinical and radiological mid-term results at five years' follow-up and seems to be a reliable implant.
Collapse
Affiliation(s)
- Kevin Madörin
- Department of Orthopedics and Trauma Surgery, Kantonsspital Baselland
| | - Wolf Siepen
- Department of Orthopedics and Trauma Surgery, Kantonsspital Baselland
| | - Isabella Manzoni
- Department of Orthopedics and Trauma Surgery, Kantonsspital Baselland
| | | | | | - Martin Clauss
- Department of Orthopedics and Trauma Surgery, Kantonsspital Baselland
| |
Collapse
|
23
|
Sesselmann S, Hong Y, Schlemmer F, Hussnaetter I, Mueller LA, Forst R, Tschunko F. Radiostereometric migration measurement of an uncemented Cerafit® femoral stem: 26 patients followed for 10 years. ACTA ACUST UNITED AC 2019; 63:657-663. [PMID: 28820728 DOI: 10.1515/bmt-2016-0251] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Accepted: 07/03/2017] [Indexed: 11/15/2022]
Abstract
Radiostereometric analysis (RSA) is the gold standard for evaluating micromotions of orthopaedic implants. The method is applied for identifying novel design weaknesses in endoprostheses. Current research frequently assesses relatively short time periods. Short-term RSA studies have been widely used for predicting the long-term stability of many hip prosthetic designs, but only a few studies have focused on uncemented hip implants, especially for extended periods. The purpose of this study was to analyse the migration pattern of the Cerafit® femoral stem within 10 years and to verify the predictive value of short-term RSA after 2 years for this uncemented femoral hip stem. Twenty-six patients were followed for 10 years. Ten years after implantation, a mean subsidence of 0.22 mm±0.56 mm, a mean internal rotation of 0.59°±1.67° and a mean maximum total point motion (MTPM) of 1.28 mm±0.54 mm were detected. The main migration took place in the first 6 weeks after surgery (subsidence of 0.36 mm±0.73 mm; internal rotation of 0.62°±1.49°, MTPM of 1.05 mm±0.68 mm). All the migration values measured were small. No late-onset migration was observed. This study suggests that the Cerafit® implants are stable after 10 years. Thus, RSA could be the best tool to assess long-term implant behaviour.
Collapse
Affiliation(s)
- Stefan Sesselmann
- Department of Orthopaedic Surgery, University of Erlangen-Nuremberg, Rathsberger Str. 57, 91054 Erlangen, Germany
| | - Yotung Hong
- Department of Orthopaedic Surgery, University of Erlangen-Nuremberg, Rathsberger Str. 57, 91054 Erlangen, Germany
| | - Frank Schlemmer
- Department of Orthopaedic Surgery, University of Erlangen-Nuremberg, Rathsberger Str. 57, 91054 Erlangen, Germany
| | - Isabell Hussnaetter
- Department of Orthopaedic Surgery, University of Erlangen-Nuremberg, Rathsberger Str. 57, 91054 Erlangen, Germany
| | - Lutz A Mueller
- Department of Orthopaedic Surgery, University of Erlangen-Nuremberg, Rathsberger Str. 57, 91054 Erlangen, Germany
| | - Raimund Forst
- Department of Orthopaedic Surgery, University of Erlangen-Nuremberg, Rathsberger Str. 57, 91054 Erlangen, Germany
| | - Franz Tschunko
- Department of Neuroradiology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany
| |
Collapse
|
24
|
Teeter MG, McCalden RW, Yuan X, MacDonald SJ, Naudie DD. Predictive accuracy of RSA migration thresholds for cemented total hip arthroplasty stem designs. Hip Int 2018; 28:363-368. [PMID: 29781291 DOI: 10.1177/1120700018762179] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Radiostereometric analysis (RSA) migration thresholds for cemented total hip stems have been established beyond which an unacceptably high risk of revision is likely to occur. These thresholds are subsidence >0.23 mm or >1.2 mm after 2 years. The purpose of this study was to retrospectively examine after long-term follow-up the predictive accuracy of the two thresholds. METHODS Data from two previous prospective RSA trials with 2 year follow-up for which minimum 10 year survivorship data was available were used. Thirty-six patients received a Spectron stem, 17 patients received an Exeter stem, and 17 patients received a CPCS stem. Subsidence after 2 years was compared to the migration thresholds, and long-term survivorship and clinical outcome scores were obtained. RESULTS At 2 years, the Spectron stem subsided 0.046 ± 0.160 mm, the Exeter stem subsided 1.218 ± 0.320 mm, and the CPCS stem subsided 0.681 ± 0.246 mm ( p < 0.0001). The Spectron stem passed both thresholds, the Exeter stem failed both thresholds, and the CPCS stem passed 1 and failed 1 threshold. At 10 years, survivorship exceeded 90% for all stems. CONCLUSION All stems demonstrated strong 10 year survivorship and equivalent clinical outcome scores, but this success would not have been equally predicted across RSA migration thresholds. Although RSA is a useful predictive tool, care should be taken in applying migration thresholds only to those stem designs they are indicated for, with the threshold of 1.2 mm of subsidence at 2 years being most broadly applicable.
Collapse
Affiliation(s)
- Matthew G Teeter
- 1 Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, ON, Canada.,4 Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - Richard W McCalden
- 1 Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, ON, Canada
| | - Xunhua Yuan
- 4 Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - Steven J MacDonald
- 1 Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, ON, Canada
| | - Douglas D Naudie
- 1 Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, ON, Canada.,2 Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| |
Collapse
|
25
|
Kim SM, Han SB, Rhyu KH, Yoo JJ, Oh KJ, Yoo JH, Lee KJ, Lim SJ. Periprosthetic femoral fracture as cause of early revision after short stem hip arthroplasty-a multicentric analysis. INTERNATIONAL ORTHOPAEDICS 2018; 42:2069-2076. [PMID: 29651610 DOI: 10.1007/s00264-018-3930-y] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Accepted: 04/03/2018] [Indexed: 12/13/2022]
Abstract
BACKGROUND The objective of this study was to analyze the prevalence and causes of early re-operation after hip replacement surgery using short bone-preserving stems in a large multicentre series. Specifically, we evaluated the clinical features of periprosthetic fractures occurring around short stems. METHODS A total of 897 patients (1089 hips) who underwent primary total hip arthroplasty or bipolar hemiarthroplasty from January 2011 to February 2015 using short bone-preserving femoral stems were recruited. Mean patient age was 57.4 years (range, 18-97 years), with a male ratio of 49.7% (541/1089). Re-operation for any reason within two years was used as an endpoint. The incidence and clinical characteristics of the periprosthetic femoral fractures were also recorded. Mean follow-up period was 5.1 years (range, 2-7.9 years). RESULTS Early re-operation for any reason was identified in 16 (1.5%) of 1089 hips. The main reason for re-operation was periprosthetic femoral fracture, which accounted for eight (50%) of the 16 re-operations. The overall incidence of periprosthetic femoral fracture at two years was 1.1% (12/1089). According to the Vancouver classification, two fractures were AG type and the other ten were B1 type. Advanced age, higher American Society of Anesthesiologist grade, femur morphology of Dorr type C, and the use of a calcar-loading stem increased the risk for periprosthetic femoral fracture. CONCLUSION Periprosthetic femoral fracture was the major reason for re-operation after hip replacement surgery using short bone-preserving stems accounting for 50% (8/16) of re-operations two years post-operatively, but did not seem to deteriorate survivorship of implanted prostheses.
Collapse
Affiliation(s)
- Sang-Min Kim
- Department of Orthopaedic Surgery, Korea University Guro Hospital, Korea University School of Medicine, Seoul, South Korea
| | - Seung-Beom Han
- Department of Orthopedic Surgery, College of Medicine, Anam Hospital, Korea University, Seoul, South Korea
| | - Kee Hyung Rhyu
- Department of Orthopedic Surgery, College of Medicine, Kyung Hee University Hospital at Gangdong, Kyung-Hee University, Seoul, South Korea
| | - Jeong Joon Yoo
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Kwang-Jun Oh
- Department of Orthopedic Surgery, Konkuk University Hospital, Konkuk University School of Medicine, Seoul, South Korea
| | - Je Hyun Yoo
- Department of Orthopedic Surgery, Hallym University Sacred Heart hospital, Anyang, South Korea
| | - Kyung-Jae Lee
- Department of Orthopedic Surgery, Dongsan Medical Center, Keimyung University School of Medicine, Daegu, South Korea
| | - Seung-Jae Lim
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, Seoul, 135-710, South Korea.
| |
Collapse
|
26
|
Sesselmann S, Hong Y, Schlemmer F, Wiendieck K, Söder S, Hussnaetter I, Müller LA, Forst R, Wierer T. Migration measurement of the cemented Lubinus SP II hip stem - a 10-year follow-up using radiostereometric analysis. ACTA ACUST UNITED AC 2017; 62:271-278. [PMID: 27416615 DOI: 10.1515/bmt-2015-0172] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2015] [Accepted: 06/20/2016] [Indexed: 12/22/2022]
Abstract
In a previous radiostereometric analysis (RSA) of the Lubinus SP II (Link, Hamburg, Germany), which is one of the most often used cemented hip stems worldwide, our research group detected a very small but statistically significant distal migration of -0.03±0.17 mm 2 years after surgery compared to the postoperative radiograph. Maximum subsidence occurred between 6 and 12 months. The implant appeared to have stabilized after 2 years. The mean value of maximum total point motion (MTPM) was 0.99±0.69 mm, which was detected 2 years after surgery. The purpose of this study was to analyze the migration pattern and to verify the predictive value of short-term RSA of the Lubinus SP II stem after 10 years. After a follow-up of 5 and 10 years, 38 and 27 out of 100 patients remained available for further assessment, respectively. No statistically significant implant translation or rotation was found along or about the axes of the global coordinate system 5 and 10 years after surgery with respect to the postoperative radiograph. Furthermore, the MTPM was stable in both follow-up periods. The results suggest that the Lubinus SP II hip stem is still stable 10 years after surgery, supporting that determining prognosis by short-term RSA follow-up of 2 years could be an appropriate tool for appraisal of implant behavior 10 years after surgery.
Collapse
|
27
|
Weber E, Olsson C, Kesteris U, Flivik G. Is a hollow centralizer necessary when using a polished, tapered, cemented femoral stem? Acta Orthop 2017; 88:377-382. [PMID: 28418269 PMCID: PMC5499327 DOI: 10.1080/17453674.2017.1315553] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - A tapered, polished and collarless stem is normally equipped with a hollow centralizer to prevent the stem from becoming end-bearing in the cement as the stem subsides. In a randomized clinical trial, we evaluated such a stem (MS-30), which was initially introduced with a solid centralizer but was later recommended to be fitted with a hollow centralizer. We hypothesized that while the stem would sink more, it would become rotationally stable and have less retroversion with a hollow centralizer than with a solid centralizer. Patients and methods - We randomized 60 patients with primary hip arthritis to receive either a hollow centralizer or a solid centralizer with the stem. The effect was evaluated over a 10-year follow-up period with repeated RSA examinations, conventional radiographs, and clinical follow-ups using the WOMAC and SF-12 questionnaires. Results - At 10-year follow-up, the group with hollow centralizers had subsided more than the group with solid centralizers (1.99 mm (hollow) as opposed to 0.57 mm (solid); p < 0.001). However, rotation was similar at 10-year follow-up (mean retroversion 1.34° (hollow) and 1.30° (solid)). Both groups showed excellent 10-year results, with similar clinical outcome, and none of the stems were radiographically loose or had been revised. Interpretation - As expected, there was more subsidence in the group with hollow centralizers, and with similar magnitude to that reported in earlier RSA studies on conceptually similar prostheses. Interestingly, there was no difference in the rotational behavior of the prostheses. This stem type appears to have a design that, regardless of the type of centralizer and the possibility of subsidence, withstands the rotational forces it is subjected to very well. This study does not support the need for a hollow centralizer for these types of stems.
Collapse
Affiliation(s)
- Erik Weber
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund;,Correspondence:
| | - Christer Olsson
- Department of Orthopedics, Blekinge County Hospital, Karlshamn, Sweden
| | - Uldis Kesteris
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund
| | - Gunnar Flivik
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund
| |
Collapse
|
28
|
Desy NM, Johnson JD, Sierra RJ. Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty. J Arthroplasty 2017; 32:494-498. [PMID: 27600303 DOI: 10.1016/j.arth.2016.07.051] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 07/22/2016] [Accepted: 07/26/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. METHODS Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. RESULTS The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. CONCLUSION The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired.
Collapse
Affiliation(s)
- Nicholas M Desy
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Joshua D Johnson
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
29
|
van der Voort P, Valstar ER, Kaptein BL, Fiocco M, van der Heide HJL, Nelissen RGHH. Comparison of femoral component migration between Refobacin bone cement R and Palacos R + G in cemented total hip arthroplasty: A randomised controlled roentgen stereophotogrammetric analysis and clinical study. Bone Joint J 2016; 98-B:1333-1341. [PMID: 27694586 DOI: 10.1302/0301-620x.98b10.37116] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2015] [Accepted: 05/12/2016] [Indexed: 11/05/2022]
Abstract
AIMS The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotogrammetric analysis (RSA). PATIENTS AND METHODS In this blinded, randomised, clinical RSA study, the migration of the Stanmore femoral component was compared between Refobacin bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties. The primary outcome measure was femoral component migration measured using RSA and secondary outcomes were Harris hip score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D) and Short Form 36 (SF-36). RESULTS Femoral component migration was comparable between Refobacin bone cement R and Palacos R + G during the two-year follow-up period with an estimated mean difference of 0.06 mm of subsidence (p = 0.56) and 0.08° of retroversion (p = 0.82). Five hips (three Refobacin bone cement R and two Palacos R + G) showed non-stabilising, continuous migration; the femoral cement mantle in these hips, was mean 0.7 mm thicker (p = 0.02) and there were more radiolucencies at the bone-cement interface (p = 0.004) in comparison to hips showing stabilising migration. Post-operative HHS was comparable throughout the follow-up period (p = 0.62). HOOS, EQ5D, and SF-36 scores were also comparable (p-values > 0.05) at the two-year follow-up point. CONCLUSION Refobacin bone cement R and Palacos R + G show comparable component migration and clinical outcome during the first two post-operative years. Hips showing continuous migration are at risk for early failure. However, this seems to be unrelated to cement type, but rather to cementing technique. Cite this article: Bone Joint J 2016;98-B:1333-41.
Collapse
Affiliation(s)
- P van der Voort
- Leiden University Medical Center, Albinusdreef 2, J11-R-70, Leiden, 2333 ZA, The Netherlands
| | - E R Valstar
- Leiden University Medical Center, Albinusdreef 2, J11-R-70, Leiden, 2333 ZA, The Netherlands
| | - B L Kaptein
- Leiden University Medical Center, Albinusdreef 2, J11-R-70, Leiden, 2333 ZA, The Netherlands
| | - M Fiocco
- Leiden University Medical Center, Albinusdreef 2, J11-R-70, Leiden, 2333 ZA, The Netherlands
| | - H J L van der Heide
- Leiden University Medical Center, Albinusdreef 2, J11-R-70, Leiden, 2333 ZA, The Netherlands
| | - R G H H Nelissen
- Leiden University Medical Center, Albinusdreef 2, J11-R-70, Leiden, 2333 ZA, The Netherlands
| |
Collapse
|
30
|
Meinardi JE, Valstar ER, Van Der Voort P, Kaptein BL, Fiocco M, Nelissen RGHH. Palacos compared to Palamed bone cement in total hip replacement: a randomized controlled trial. Acta Orthop 2016; 87:473-8. [PMID: 27329869 PMCID: PMC5016905 DOI: 10.1080/17453674.2016.1199146] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Stability and survival of cemented total hip prostheses is dependent on a multitude of factors, including the type of cement that is used. Bone cements vary in viscosity, from low to medium and high. There have been few clinical RSA studies comparing the performance of low- and high-viscosity bone cements. We compared the migration behavior of the Stanmore hip stem cemented using novel low-viscosity Palamed bone cement with that of the same stem cemented with conventional high-viscosity Palacos bone cement. Patients and methods - We performed a randomized controlled study involving 39 patients (40 hips) undergoing primary total hip replacement for primary or secondary osteoarthritis. 22 patients (22 hips) were randomized to Palacos and 17 patients (18 hips) were randomized to Palamed. Migration was determined by RSA. Results - None of these 40 hips had been revised at the 10-year follow-up mark. To our knowledge, the patients who died before they reached the 10-year endpoint still had the implant in situ. No statistically significant or clinically significant differences were found between the 2 groups for mean translations, rotations, and maximum total-point motion (MTPM). Interpretation - We found similar migration of the Stanmore stem in the high-viscosity Palacos cement group and the low-viscosity Palamed cement group. We therefore expect that the risk of aseptic loosening with the new Palamed cement would be comparable to that with the conventional Palacos cement. The choice of which type of bone cement to use is therefore up to the surgeon's preference.
Collapse
Affiliation(s)
- Joris E Meinardi
- Department of Orthopaedics, Leiden University Medical Center (LUMC), Leiden;,Correspondence:
| | - Edward R Valstar
- Department of Orthopaedics, Leiden University Medical Center (LUMC), Leiden;,Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Delft
| | - Paul Van Der Voort
- Department of Orthopaedics, Leiden University Medical Center (LUMC), Leiden
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center (LUMC), Leiden
| | - Marta Fiocco
- Department of Medical Statistics and Bioinformatics, Leiden University Medical Center (LUMC), Leiden;,Mathematical Institute, Leiden University, Leiden, the Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center (LUMC), Leiden
| |
Collapse
|
31
|
Siepen W, Zwicky L, Stoffel KK, Ilchmann T, Clauss M. Prospective two-year subsidence analysis of 100 cemented polished straight stems - a short-term clinical and radiological observation. BMC Musculoskelet Disord 2016; 17:395. [PMID: 27640188 PMCID: PMC5027091 DOI: 10.1186/s12891-016-1247-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2016] [Accepted: 09/09/2016] [Indexed: 01/14/2023] Open
Abstract
Background Cemented stems show good long-term results and the survival of new implants can be predicted by their early subsidence. With EBRA-FCA (Femoral Component Analysis using Einzel-Bild-Röntgen-Analyse) early subsidence as an early indicator for later aseptic loosening can be analysed. For the cemented TwinSys stem mid- and long-term data is only avalible from the New Zeeland Arthroplasty register, thus close monitoring of this implant system is still mandatory. Methods We conducted a 2 year follow up of 100 consecutive hybrid THA (Total hip arthroplasty) of a series of 285 primary THA operated between Jan 2009 und Oct 2010. These 100 received a polished, cemented collarless straight stem (twinSys®, Mathys AG® Bettlach, Switzerland) with an uncemented monobloc pressfit cup (RM pressfit®, Mathys AG® Bettlach, Switzerland). The other patients were treated with the uncemented version of this stem and the same cup. Clinical (Harris Hip Score) and radiological (ap and axial x-rays, cementing quality according to Barrack, alignment) outcomes besides an EBRA-FCA subsidence analysis were performed. Results Median age at operation was 78 (68 to 93) years. 5 patients died in the course of follow-up unrelated to surgery. The KM (Kaplan-Meier) survival at 2 years for the endpoint reoperation for any reason was 94.9 (95 % confidence interval 90.6–100 %). Survival for the endpoint aseptic loosening at 2 years was 100 %. The HHS (Harris Hip Score) improved from 56 (14–86) preoperatively to 95 (60–100) 2 years after the operation. Cementing results were judged 47 % Grade A, 45 % Grade B and 7 % Grade C. Osteolysis was found in 2 stems without clinical symptoms or correlation to subsidence or cementing quality. The EBRA-FCA analysis showed an average subsidence of -0.30 mm (95 % CI -0.5 mm to -0.1 mm). 11 patients showed a subsidence of more than 1 mm. In this group one patient showed a subsidence of 1.5 mm and one of 3.1 mm without further radiological changes. Conclusions The twinSys stem showed excellent clinical and radiologic short term results at 2 years follow-up and seems to be a reliable implant.
Collapse
Affiliation(s)
- Wolf Siepen
- Department for Orthopaedics and Trauma Surgery, Kantonsspital Baselland, CH-4410, Liestal, Switzerland.
| | - Lukas Zwicky
- Department for Orthopaedics and Trauma Surgery, Kantonsspital Baselland, CH-4410, Liestal, Switzerland
| | - Karl Kilian Stoffel
- Department for Orthopaedics and Trauma Surgery, Kantonsspital Baselland, CH-4410, Liestal, Switzerland
| | - Thomas Ilchmann
- LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | - Martin Clauss
- Department for Orthopaedics and Trauma Surgery, Kantonsspital Baselland, CH-4410, Liestal, Switzerland
| |
Collapse
|
32
|
Streit MR, Haeussler D, Bruckner T, Proctor T, Innmann MM, Merle C, Gotterbarm T, Weiss S. Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study. Clin Orthop Relat Res 2016; 474:1697-706. [PMID: 27130649 PMCID: PMC4887381 DOI: 10.1007/s11999-016-4857-5] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Accepted: 04/19/2016] [Indexed: 01/31/2023]
Abstract
BACKGROUND Excessive early migration of cemented stems and cups after THA has been associated with poor long-term survival and allows predictable evaluation of implant performance. However, there are few data regarding the relationship between early migration and aseptic loosening of cementless femoral components, and whether early migration might predict late failure has not been evaluated, to our knowledge. Einzel-Bild-Röntgen-Analyse-femoral component analysis (EBRA-FCA) is a validated technique to accurately measure axial femoral stem migration without the need for tantalum markers, can be performed retrospectively, and may be a suitable tool to identify poor performing implants before their widespread use. QUESTIONS/PURPOSES We asked: (1) Is axial migration within the first 24 months as assessed by EBRA-FCA greater among cementless stems that develop aseptic loosening than those that remain well fixed through the second decade; (2) what is the diagnostic performance of implant migration at 24 months postoperatively to predict later aseptic loosening of these components; and (3) how does long-term stem survivorship compare between groups with high and low early migration? METHODS We evaluated early axial stem migration in 158 cementless THAs using EBRA-FCA. The EBRA-FCA measurements were performed during the first week postoperatively (baseline measurement) and at regular followups of 3, 6, and 12 months postoperatively and annually thereafter. The mean duration of followup was 21 years (range, 18-24 years). The stems studied represented 45% (158 of 354) of the cementless THAs performed during that time, and cementless THAs represented 34% (354 of 1038) of the THA practice during that period. No patient enrolled in this study was lost to followup. Multivariate survivorship analysis using Cox's regression model was performed with an endpoint of aseptic loosening of the femoral component. Loosening was defined according to the criteria described by Engh et al. and assessed by two independent observers. Patients with a diagnosis of prosthetic joint infection were excluded. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic performance of axial stem migration 1, 2, 3, and 4 years postoperatively as a predictor of aseptic loosening. Survivorship of hips with high (≥ 2.7 mm) and low (< 2.7 mm) migration was compared using a competing-events analysis. RESULTS Femoral components that had aseptic loosening develop showed greater mean distal migration at 24 months postoperatively than did components that remained well fixed throughout the surveillance period (4.2 mm ± 3.1 mm vs 0.8 mm ± 0.9 mm; mean difference, 3.4 mm, 95% CI, 2.5-4.4; p ≤ 0.001). Distal migration at 24 months postoperatively was a strong risk factor for aseptic loosening (hazard ratio, 1.98; 95% CI, 1.51-2.57; p < 0.001). The associated overall diagnostic performance of 2-year distal migration for predicting aseptic loosening was good (area under the ROC curve, 0.86; 95% CI, 0.72-1.00; p < 0.001). Sensitivity of early migration measurement was high for the prediction of aseptic loosening during the first decade after surgery but decreased markedly thereafter. Stems with large amounts of early migration (≥ 2.7 mm) had lower 18-year survivorship than did stems with little early migration (29% [95% CI, 0%-62%] versus 95% [95% CI, 90%-100%] p < 0.001). CONCLUSIONS Early migration, as measured by EBRA-FCA at 2 years postoperatively, has good diagnostic capabilities for detection of uncemented femoral components at risk for aseptic loosening during the first and early second decades after surgery. However, there was no relationship between early migration patterns and aseptic loosening during the late second and third decades. EBRA-FCA can be used as a research tool to evaluate new cementless stems or in clinical practice to evaluate migration patterns in patients with painful femoral components. LEVEL OF EVIDENCE Level III, diagnostic study.
Collapse
Affiliation(s)
- Marcus R. Streit
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Daniel Haeussler
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Thomas Bruckner
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Tanja Proctor
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Moritz M. Innmann
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Christian Merle
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Tobias Gotterbarm
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany
| | - Stefan Weiss
- Clinic of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University of Heidelberg, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany ,Department of Joint Replacement Surgery, ARCUS Kliniken Pforzheim, Pforzheim, Germany
| |
Collapse
|
33
|
Malak TT, Broomfield JAJ, Palmer AJR, Hopewell S, Carr A, Brown C, Prieto-Alhambra D, Glyn-Jones S. Surrogate markers of long-term outcome in primary total hip arthroplasty: A systematic review. Bone Joint Res 2016; 5:206-14. [PMID: 27267795 PMCID: PMC4921042 DOI: 10.1302/2046-3758.56.2000568] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Accepted: 03/23/2016] [Indexed: 12/24/2022] Open
Abstract
Objectives High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing primary total hip arthroplasty (THA). Methods We conducted a systematic review of studies evaluating surrogate markers for predicting long-term outcome in primary THA. Long-term outcome was defined as revision rate of an implant at ten years according to National Institute of Health and Care Excellence guidelines. We conducted a search of Medline and Embase (OVID) databases. Separate search strategies were devised for the Cochrane database and Google Scholar. Each search was performed to include articles from the date of their inception to June 8, 2015. Results Our search strategy identified 1082 studies of which 115 studies were included for full article review. Following review, 17 articles were found that investigated surrogate markers of long-term outcome. These included one systematic review, one randomised control trial (RCT), one case control study and 13 case series. Validated surrogate markers included Radiostereometric Analysis (RSA) and Einzel-Bild-Röntgen-Analyse (EBRA), each measuring implant migration and wear. We identified five RSA studies (one systematic review and four case series) and four EBRA studies (one RCT and three case series). Patient Reported Outcome Measures (PROMs) at six months have been investigated but have not been validated against long-term outcomes. Conclusions This systematic review identified two validated surrogate markers of long-term primary THA outcome: RSA and EBRA, each measuring implant migration and wear. We recommend the consideration of RSA in the pre-market testing of new implants. EBRA can be used to investigate acetabular wear but not femoral migration. Further studies are needed to validate the use of PROMs for post-market surveillance. Cite this article: T. T. Malak, J. A. J. Broomfield, A. J. R. Palmer, S. Hopewell, A. Carr, C. Brown, D. Prieto-Alhambra, S. Glyn-Jones. Surrogate markers of long-term outcome in primary total hip arthroplasty: A systematic review. Bone Joint Res 2016;5:206–214. DOI: 10.1302/2046-3758.56.2000568.
Collapse
Affiliation(s)
- T T Malak
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - J A J Broomfield
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - A J R Palmer
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - S Hopewell
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - A Carr
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - C Brown
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - D Prieto-Alhambra
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| | - S Glyn-Jones
- Oxford NIHR Musculoskeletal Biomedical Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Lane, Oxford OX3 7LD, UK
| |
Collapse
|
34
|
Tsukanaka M, Röhrl SM, von Schewelov T, Nordsletten L. Identification of femoral head center of bipolar hemiarthroplasy in radiostereometric analysis with elementary geometrical shape models. J Biomech 2016; 49:469-73. [PMID: 26705109 DOI: 10.1016/j.jbiomech.2015.11.054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Revised: 11/20/2015] [Accepted: 11/22/2015] [Indexed: 11/28/2022]
Abstract
Elementary geometrical shape (EGS) models are useful in radiostereometric analysis (RSA) on hip stems because tantalum markers attached to the stems can be omitted. In order to create an EGS model of a femoral stem, the center of the femoral head has to be identified. The contour of the femoral head is recommended to be used. However, the contour of the femoral head cannot be detected exclusively by computer if it is combined with a bipolar head or a metal cup. We therefore hypothesized that the contour of the outer head of bipolar hemiarthroplasty can be included in the EGS model as well as the femoral head contour. We calculated the time required for the detection of the contour, the precision of analysis and the stem micromotion at 2 years using the two different methods in the same picture set and compared the results. The detection of the bipolar head contour was 10 times faster than that of the femoral head contour. The precision for subsidence was 0.16 mm in EGS RSA with the femoral head contour, and 0.15 mm with the bipolar head contour (p=0.68). The precisions were comparable and clinically acceptable. There was no significant difference between the results of the 2-year micromotion with the two different methods. We conclude that this new method is applicable to measure stem micromotion of hemi-arthroplasty with EGS RSA and the method facilitates the Radiostereometric analysis.
Collapse
Affiliation(s)
- Masako Tsukanaka
- Center for Implant and Radiostereometric Research Oslo, Oslo University Hospital, Ullevål, Oslo, Norway.
| | - Stephan M Röhrl
- Center for Implant and Radiostereometric Research Oslo, Oslo University Hospital, Ullevål, Oslo, Norway
| | - Thord von Schewelov
- Department of Orthopaedics and Clinical Sciences, Lund University, Skane University Hospital, Malmö, Sweden
| | - Lars Nordsletten
- Center for Implant and Radiostereometric Research Oslo, Oslo University Hospital, Ullevål, Oslo, Norway
| |
Collapse
|
35
|
Ka-Bon K, Jason FCH, Bobby NKW. The Polished MS-30 Stem with a Solid Centralizer: A Minimum 10-year Review of Radiological and Clinical Outcomes. JOURNAL OF ORTHOPAEDICS, TRAUMA AND REHABILITATION 2015. [DOI: 10.1016/j.jotr.2014.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
Background/Purpose MS-30 is a triple tapered cemented femoral stem. Before 2005, it was used together with a solid centralizer. We wanted to investigate its effect on the migration behaviour and survivorship of polished stem with a minimum of 10 years. Methods Twenty-seven hips in 26 patients were available for follow-up. The mean length of follow-up was 12.1 years. Clinical outcomes were documented with the Harris Hip Score. Radiographs were examined for evidence of aseptic loosening. Results The average Harris Hip Score was 74.8. No stem was revised for aseptic loosening. Two stems (7.4%) developed radiolucent lines of more than 2 mm width with osteolysis. The mean subsidence was 0.77 mm. The survival rate at the 10th postoperative year, with aseptic loosening as the end point, was 100%. Conclusion The polished MS-30 stem with a solid centralizer has a satisfactory long-term outcome. Its mean subsidence was less than that of other polished tapered stems reported in the literature.
Collapse
Affiliation(s)
- Kwok Ka-Bon
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong
| | - Fan Chi-Ho Jason
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong
| | - Ng Kin-Wan Bobby
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong
| |
Collapse
|
36
|
Clarke A, Pulikottil-Jacob R, Grove A, Freeman K, Mistry H, Tsertsvadze A, Connock M, Court R, Kandala NB, Costa M, Suri G, Metcalfe D, Crowther M, Morrow S, Johnson S, Sutcliffe P. Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): systematic review and economic evaluation. Health Technol Assess 2015; 19:1-668, vii-viii. [PMID: 25634033 DOI: 10.3310/hta19100] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Total hip replacement (THR) involves the replacement of a damaged hip joint with an artificial hip prosthesis. Resurfacing arthroplasty (RS) involves replacement of the joint surface of the femoral head with a metal surface covering. OBJECTIVES To undertake clinical effectiveness and cost-effectiveness analysis of different types of THR and RS for the treatment of pain and disability in people with end-stage arthritis of the hip, in particular to compare the clinical effectiveness and cost-effectiveness of (1) different types of primary THR and RS for people in whom both procedures are suitable and (2) different types of primary THR for people who are not suitable for hip RS. DATA SOURCES Electronic databases including MEDLINE, EMBASE, The Cochrane Library, Current Controlled Trials and UK Clinical Research Network (UKCRN) Portfolio Database were searched in December 2012, with searches limited to publications from 2008 and sample sizes of ≥ 100 participants. Reference lists and websites of manufacturers and professional organisations were also screened. REVIEW METHODS Systematic reviews of the literature were undertaken to appraise the clinical effectiveness and cost-effectiveness of different types of THR and RS for people with end-stage arthritis of the hip. Included randomised controlled trials (RCTs) and systematic reviews were data extracted and risk of bias and methodological quality were independently assessed by two reviewers using the Cochrane Collaboration risk of bias tool and the Assessment of Multiple Systematic Reviews (AMSTAR) tool. A Markov multistate model was developed for the economic evaluation of the technologies. Sensitivity analyses stratified by sex and controlled for age were carried out to assess the robustness of the results. RESULTS A total of 2469 records were screened of which 37 were included, representing 16 RCTs and eight systematic reviews. The mean post-THR Harris Hip Score measured at different follow-up times (from 6 months to 10 years) did not differ between THR groups, including between cross-linked polyethylene and traditional polyethylene cup liners (pooled mean difference 2.29, 95% confidence interval -0.88 to 5.45). Five systematic reviews reported evidence on different types of THR (cemented vs. cementless cup fixation and implant articulation materials) but these reviews were inconclusive. Eleven cost-effectiveness studies were included; four provided relevant cost and utility data for the model. Thirty registry studies were included, with no studies reporting better implant survival for RS than for all types of THR. For all analyses, mean costs for RS were higher than those for THR and mean quality-adjusted life-years (QALYs) were lower. The incremental cost-effectiveness ratio for RS was dominated by THR, that is, THR was cheaper and more effective than RS (for a lifetime horizon in the base-case analysis, the incremental cost of RS was £11,284 and the incremental QALYs were -0.0879). For all age and sex groups RS remained clearly dominated by THR. Cost-effectiveness acceptability curves showed that, for all patients, THR was almost 100% cost-effective at any willingness-to-pay level. There were age and sex differences in the populations with different types of THR and variations in revision rates (from 1.6% to 3.5% at 9 years). For the base-case analysis, for all age and sex groups and a lifetime horizon, mean costs for category E (cemented components with a polyethylene-on-ceramic articulation) were slightly lower and mean QALYs for category E were slightly higher than those for all other THR categories in both deterministic and probabilistic analyses. Hence, category E dominated the other four categories. Sensitivity analysis using an age- and sex-adjusted log-normal model demonstrated that, over a lifetime horizon and at a willingness-to-pay threshold of £20,000 per QALY, categories A and E were equally likely (50%) to be cost-effective. LIMITATIONS A large proportion of the included studies were inconclusive because of poor reporting, missing data, inconsistent results and/or great uncertainty in the treatment effect estimates. This warrants cautious interpretation of the findings. The evidence on complications was scarce, which may be because of the absence or rarity of these events or because of under-reporting. The poor reporting meant that it was not possible to explore contextual factors that might have influenced study results and also reduced the applicability of the findings to routine clinical practice in the UK. The scope of the review was limited to evidence published in English in 2008 or later, which could be interpreted as a weakness; however, systematic reviews would provide summary evidence for studies published before 2008. CONCLUSIONS Compared with THR, revision rates for RS were higher, mean costs for RS were higher and mean QALYs gained were lower; RS was dominated by THR. Similar results were obtained in the deterministic and probabilistic analyses and for all age and sex groups THR was almost 100% cost-effective at any willingness-to-pay level. Revision rates for all types of THR were low. Category A THR (cemented components with a polyethylene-on-metal articulation) was more cost-effective for older age groups. However, across all age-sex groups combined, the mean cost for category E THR (cemented components with a polyethylene-on-ceramic articulation) was slightly lower and the mean QALYs gained were slightly higher. Category E therefore dominated the other four categories. Certain types of THR appeared to confer some benefit, including larger femoral head sizes, use of a cemented cup, use of a cross-linked polyethylene cup liner and a ceramic-on-ceramic as opposed to a metal-on-polyethylene articulation. Further RCTs with long-term follow-up are needed. STUDY REGISTRATION This study is registered as PROSPERO CRD42013003924. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Aileen Clarke
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Amy Grove
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Karoline Freeman
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Hema Mistry
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Martin Connock
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Rachel Court
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Matthew Costa
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Gaurav Suri
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - David Metcalfe
- Warwick Orthopaedics, University Hospitals Coventry and Warwickshire, Coventry, UK
| | - Michael Crowther
- Department of Health Sciences, University of Leicester, Leicester, UK
| | - Sarah Morrow
- Oxford Medical School, University of Oxford, Oxford, UK
| | - Samantha Johnson
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Paul Sutcliffe
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| |
Collapse
|
37
|
Rajakulendran K, Strambi F, Ruggeri R, Field RE. A Cannulated Tri-Tapered Femoral Stem for Total Hip Arthroplasty: Clinical and Radiological Results at Ten Years. J Arthroplasty 2015; 30:1772-6. [PMID: 25956523 DOI: 10.1016/j.arth.2015.04.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Revised: 02/23/2015] [Accepted: 04/18/2015] [Indexed: 02/01/2023] Open
Abstract
We report the ten-year clinical and radiological outcomes of a novel cannulated, tri-tapered femoral stem, used in primary total hip arthroplasty (110 stems in 98 patients). At ten years, two Tri-taper stems had been revised for infection and dislocation. The mean Oxford Hip Score improved from 13.46 pre-operatively, to 37.04. Radiological analysis revealed radiolucent lines in 57 cases, but none exceeded 2 mm thickness. Stem subsidence was identified in 63 cases, with mean distal tip migration of 3.8 mm. Survivorship with revision for aseptic loosening as the end point was 100% at 10 years. Stem survival with revision for any cause was 98.2% (95% CI, 92.9% to 99.5%). The ten-year results of the Tri-taper stem are comparable to other polished, tapered femoral stems.
Collapse
Affiliation(s)
- Karthig Rajakulendran
- The Royal National Orthopaedic Hospital, Stanmore, Middlesex, United Kingdom; The Elective Orthopaedic Centre, Epsom, Surrey, United Kingdom
| | | | | | - Richard E Field
- The Elective Orthopaedic Centre, Epsom, Surrey, United Kingdom; St George's, University of London, Cranmer Terrace, London, United Kingdom
| |
Collapse
|
38
|
Budde S, Seehaus F, Schwarze M, Hurschler C, Floerkemeier T, Windhagen H, Noll Y, Ettinger M, Thorey F. Analysis of migration of the Nanos® short-stem hip implant within two years after surgery. INTERNATIONAL ORTHOPAEDICS 2015; 40:1607-1614. [PMID: 26404094 DOI: 10.1007/s00264-015-2999-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Accepted: 09/14/2015] [Indexed: 02/07/2023]
Abstract
PURPOSE Short-stem implants provide a bone-preserving alternative in total hip arthroplasty. However, some evidence exists that the smaller implant-bone contact surface may compromise primary stability and impair osseo-integration. The purpose of this study was to analyse the migration characteristics of the Nanos® short stem over two years by means of model-based roentgen stereophotogrammetric analysis (MBRSA). METHODS Eighteen patients aged 53.6 ± 7.2 years were included. After being treated with a Nanos implant, 14 patients were followed-up radiologically at three, six, 12 and 24 months by means of MBRSA. Early implant migration was calculated. Clinical data have been assessed in addition. RESULTS Highest translational migration was observed with a mean value of -0.22 ± 0.39 mm along the proximo-distal axis after three months and highest rotational migration with 0.8 ± 3.2° also around the y-axis after two years. The resulting total migration was 0.46 ± 0.31 mm, with the largest proportion occurring within three months after surgery (0.40 ± 0.34 mm). CONCLUSION The Nanos short-stem hip implant shows only a slight initial migration within three months after implantation, followed by secondary stabilisation. These results suggest both good primary stability and osseo-integration, suggesting a low risk of aseptic loosening.
Collapse
Affiliation(s)
- Stefan Budde
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
| | - Frank Seehaus
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Michael Schwarze
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Christof Hurschler
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Thilo Floerkemeier
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Henning Windhagen
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Yvonne Noll
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Max Ettinger
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
| | - Fritz Thorey
- Centre for Hip, Knee and Foot Surgery, Sports Traumatology, ATOS Hospital, Bismarckstr. 9-15, 69115, Heidelberg, Germany
| |
Collapse
|
39
|
Glennie RA, Giles JW, Johnson JA, Athwal GS, Faber KJ. An in vitro study comparing limited to full cementation of polyethylene glenoid components. J Orthop Surg Res 2015; 10:142. [PMID: 26383832 PMCID: PMC4573681 DOI: 10.1186/s13018-015-0268-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2015] [Accepted: 07/28/2015] [Indexed: 11/10/2022] Open
Abstract
Background Glenoid component survival is critical to good long-term outcomes in total shoulder arthroplasty. Optimizing the fixation environment is paramount. The purpose of this study was to compare two glenoid cementing techniques for fixation in total shoulder arthroplasty. Methods Sixteen cadaveric specimens were randomized to receive peg-only cementation (CPEG) or full back-side cementation (CBACK). Physiological cyclic loading was performed and implant displacement was recorded using an optical tracking system. The cement mantle was examined with micro-computed tomography before and after cyclic loading. Results Significantly greater implant displacement away from the inferior portion of the glenoid was observed in the peg cementation group when compared to the fully cemented group during the physiological loading. The displacement was greatest at the beginning of the loading protocol and persisted at a diminished rate during the remainder of the loading protocol. Micro-CT scanning demonstrated that the cement mantle remained intact in both groups and that three specimens in the CBACK group demonstrated microfracturing in one area only. Discussion Displacement of the CPEG implants away from the inferior subchondral bone may represent a suboptimal condition for long-term implant survival. Cement around the back of the implant is suggested to improve initial stability of all polyethylene glenoid implants. Clinical relevance Full cementation provides greater implant stability when compared to limited cementation techniques for insertion of glenoid implants. Loading characteristics are more favorable when cement is placed along the entire back of the implant contacting the subchondral bone.
Collapse
Affiliation(s)
- R Andrew Glennie
- Department of Orthopedics, Dalhousie University, Halifax, NS, Canada.
| | - Joshua W Giles
- Division of Orthopedics, Western University, 268 Grosvenor St, London, N6A 4L6, ON, Canada.
| | - James A Johnson
- Division of Orthopedics, Western University, 268 Grosvenor St, London, N6A 4L6, ON, Canada.
| | - George S Athwal
- Division of Orthopedics, Western University, 268 Grosvenor St, London, N6A 4L6, ON, Canada.
| | - Kenneth J Faber
- Division of Orthopedics, Western University, 268 Grosvenor St, London, N6A 4L6, ON, Canada.
| |
Collapse
|
40
|
Flatøy B, Röhrl SM, Rydinge J, Dahl J, Diep LM, Nordsletten L. Triple taper stem design shows promising fixation and bone remodelling characteristics: radiostereometric analysis in a randomised controlled trial. Bone Joint J 2015; 97-B:755-61. [PMID: 26033054 DOI: 10.1302/0301-620x.97b6.34736] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Cemented femoral stems with force closed fixation designs have shown good clinical results despite high early subsidence. A new triple-tapered stem in this category (C-stem AMT) was introduced in 2005. This study compares this new stem with an established stem of similar design (Exeter) in terms of migration (as measured using radiostereometric analysis), peri-prosthetic bone remodelling (measured using dual energy x-ray densitometry, DXA), Oxford Hip Score, and plain radiographs. A total of 70 patients (70 hips) with a mean age of 66 years (53 to 78) were followed for two years. Owing to missing data of miscellaneous reasons, the final analysis represents data from 51 (RSA) and 65 (DXA) patients. Both stems showed a typical pattern of migration: Subsidence and retroversion that primarily occurred during the first three months. C-stem AMT subsided less during the first three months (p = 0.01), before stabilising at a subsidence rate similar to the Exeter stem from years one to two. The rate of migration into retroversion was slightly higher for C-stem AMT during the second year (p = 0.03). Whilst there were slight differences in movement patterns between the stems, the C-stem AMT exhibits good early clinical outcomes and displays a pattern of migration and bone remodelling that predicts good clinical performance.
Collapse
Affiliation(s)
- B Flatøy
- Oslo University Hospital, P. O. Box 4950 Nydalen, N-0424 Oslo, Norway
| | - S M Röhrl
- Oslo University Hospital, P. O. Box 4950 Nydalen, N-0424 Oslo, Norway
| | - J Rydinge
- Oslo University Hospital, P. O. Box 4950 Nydalen, N-0424 Oslo, Norway
| | - J Dahl
- Oslo University Hospital, P. O. Box 4950 Nydalen, N-0424 Oslo, Norway
| | - L M Diep
- Oslo University Hospital, P. O. Box 4950 Nydalen, N-0424 Oslo, Norway
| | - L Nordsletten
- Oslo University Hospital, P. O. Box 4950 Nydalen, N-0424 Oslo, Norway
| |
Collapse
|
41
|
The predictive value of radiostereometric analysis for stem survival in total hip arthroplasty. A systematic review. Hip Int 2015; 24:215-22. [PMID: 24474413 DOI: 10.5301/hipint.5000102] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/08/2013] [Indexed: 02/04/2023]
Abstract
BACKGROUND The high precision of radiostereometric analysis (RSA) has enabled us to predict long-term implant survival with a small sample of patients followed for a relatively short period of time. The purpose of our systematic review was to validate the predictive value of two-year RSA results on long-term survival of different types of primary total hip arthroplasty stems. METHODS We systematically reviewed literature to determine the maximum total point motion (MTPM), distal migration and rotation of stem designs and correlated these values to survival rates for aseptic loosening of these specific stems in arthroplasty registries. RESULTS We included 32 studies describing migration of 15 different stem designs. The mean MTPM for straight polished cemented stems was 1.35 mm, for other cemented stems 0.83 mm and for other uncemented stems 1.50 mm. No data were available for the uncemented collared stem. Mean distal migration for straight polished cemented stems was 1.24 mm, for other cemented stems 0.26 mm, the uncemented collared stem 0.40 mm and for other uncemented stems 0.66 mm. Internal rotation was presented for 13 stems and all stems rotated into retroversion. All stems showed 10-year survival rates of >97% corrected for aseptic loosening. DISCUSSION Reporting RSA results in a universal way including interpretation of outliers could improve the predictive value of RSA, allowing this technique to be an important tool during the phased introduction of new implant designs. However, a quality assessment of the data by an experienced reviewer is essential.
Collapse
|
42
|
Weber E, Sundberg M, Flivik G. Design modifications of the uncemented Furlong hip stem result in minor early subsidence but do not affect further stability: a randomized controlled RSA study with 5-year follow-up. Acta Orthop 2014; 85:556-61. [PMID: 25175668 PMCID: PMC4259023 DOI: 10.3109/17453674.2014.958810] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Even small design modifications of uncemented hip stems may alter the postoperative 3-D migration pattern. The Furlong Active is an uncemented femoral stem which, in terms of design, is based on its precursor-the well-proven Furlong HAC-but has undergone several design changes. The collar has been removed on the Active stem along with the lateral fin; it is shorter and has more rounded edges in the proximal part. We compared the migration patterns of the uncemented Furlong HAC stem and the modified Furlong Active stem in a randomized, controlled trial over 5 years using radiostereometry (RSA). PATIENTS AND METHODS 50 patients with primary osteoarthritis were randomized to receive either the HAC stem or the Active stem. The patients underwent repeated RSA examinations (postoperatively, at 3 months, and after 1, 2, and 5 years) and conventional radiography, and they also filled out hip-specific questionnaires. RESULTS During the first 3 months, the collarless Active stem subsided to a greater extent than the collar-fitted HAC stem (0.99 mm vs. 0.31 mm, p=0.05). There were, however, no other differences in movement measured by RSA or in clinical outcome between the 2 stems. After 3 months, both stem types had stabilized and almost no further migration was seen. INTERPRETATION The Active stem showed no signs of unfavorable migration. Our results suggest that the osseointegration is not compromised by the new design features.
Collapse
Affiliation(s)
- Erik Weber
- Department of Orthopedics, Lund University and Skåne University Hospital, Lund, Sweden.
| | - Martin Sundberg
- Department of Orthopedics, Lund University and Skåne University Hospital, Lund, Sweden.
| | - Gunnar Flivik
- Department of Orthopedics, Lund University and Skåne University Hospital, Lund, Sweden.
| |
Collapse
|
43
|
Thien TM, Chatziagorou G, Garellick G, Furnes O, Havelin LI, Mäkelä K, Overgaard S, Pedersen A, Eskelinen A, Pulkkinen P, Kärrholm J. Periprosthetic femoral fracture within two years after total hip replacement: analysis of 437,629 operations in the nordic arthroplasty register association database. J Bone Joint Surg Am 2014; 96:e167. [PMID: 25274795 DOI: 10.2106/jbjs.m.00643] [Citation(s) in RCA: 190] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND We used the Nordic Arthroplasty Register Association database to evaluate whether age, sex, preoperative diagnosis, fixation, and implant design influence the risk of revision arthroplasty due to periprosthetic fracture within two years from operation of a primary total hip replacement. METHODS Included in the study were 325,730 cemented femoral stems and 111,899 uncemented femoral stems inserted from 1995 to 2009. Seven frequently used stems (two cemented stems [Exeter and Lubinus SP II] and five uncemented stems [Bi-Metric, Corail, CLS Spotorno, ABG I, and ABG II]) were specifically studied. RESULTS The incidence of revision at two years was low: 0.47% for uncemented stems and 0.07% for cemented stems. Uncemented stems were much more likely to have this complication (relative risk, 8.72 [95% confidence interval, 7.37 to 10.32]; p < 0.0005). Age had no consistent influence on the risk for revision of cemented stems, but revision in the uncemented group increased with increasing age. A cemented stem was associated with a higher risk in male patients compared with female patients (hazard ratio, 1.95 [95% confidence interval, 1.51 to 2.53]; p < 0.0005), whereas an uncemented stem was associated with a reduced risk in male patients compared with female patients (hazard ratio, 0.74 [95% confidence interval, 0.62 to 0.89]; p = 0.001). The risk for revision due to early periprosthetic fracture increased during the 2003 to 2009 period compared with the 1995 to 2002 period both before and after adjustment for demographic factors and fixation (relative risk, 1.44 [95% confidence interval, 1.18 to 1.69]; p < 0.0005). The hazard ratio for the Exeter stem was about five times higher than that for the Lubinus SP II stem (hazard ratio, 5.03 [95% confidence interval, 3.29 to 7.70]; p < 0.0005). Of the five uncemented stems, the ABG II stem showed an increased hazard ratio of 1.63 (95% confidence interval, 1.16 to 2.28) (p = 0.005), whereas the Corail stem showed a decreased hazard ratio of 0.47 (95% confidence interval, 0.34 to 0.65) (p < 0.0005) compared with the reference Bi-Metric design. CONCLUSIONS The shape and surface finish of the femoral stem and its fixation could be related to the increased risk of some prosthetic designs. Even if the incidence of early periprosthetic fracture in general is low and other reasons for revision must be considered, specific attention should be given to the choice of fixation and stem design in risk groups. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Truike M Thien
- Institute of Clinical Sciences, The Sahlgrenska Academy, University of Göteborg, Box 426, 40530 Göteborg, Sweden. E-mail address for T.M. Thien:
| | - Georgios Chatziagorou
- Institute of Clinical Sciences, The Sahlgrenska Academy, University of Göteborg, Box 426, 40530 Göteborg, Sweden. E-mail address for T.M. Thien:
| | - Göran Garellick
- Institute of Clinical Sciences, The Sahlgrenska Academy, University of Göteborg, Box 426, 40530 Göteborg, Sweden. E-mail address for T.M. Thien:
| | - Ove Furnes
- The Norwegian Arthroplasty Register, Department of Clinical Medicine, University of Bergen, Jonas Lies vei 65, 5021 Bergen, Norway. E-mail address for O. Furnes: . E-mail address for L.I. Havelin:
| | - Leif I Havelin
- The Norwegian Arthroplasty Register, Department of Clinical Medicine, University of Bergen, Jonas Lies vei 65, 5021 Bergen, Norway. E-mail address for O. Furnes: . E-mail address for L.I. Havelin:
| | - Keijo Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital, P.O. Box 52, 20521 Turku, Finland. E-mail address:
| | - Søren Overgaard
- Institute of Clinical Research, University of Southern Denmark, Sdr. Boulevard 29, 5000 Odense, Denmark. E-mail address:
| | - Alma Pedersen
- Department of Clinical Epidemiology, Aarhus University Hospital, Olof Palmes Alle 43-45, 8200 Aarhus, Denmark. E-mail address:
| | - Antti Eskelinen
- The Coxa Hospital for Joint Replacement, Box 652, 33101 Tampere, Finland. E-mail address:
| | - Pekka Pulkkinen
- Department of Public Health, University of Helsinki, Box 41, 00014 Helsinki, Finland. E-mail address:
| | - Johan Kärrholm
- Institute of Clinical Sciences, The Sahlgrenska Academy, University of Göteborg, Box 426, 40530 Göteborg, Sweden. E-mail address for T.M. Thien:
| |
Collapse
|
44
|
von Schewelov T, Carlsson A, Sanzén L, Besjakov J. Continuous distal migration and internal rotation of the C-stem prosthesis without any adverse clinical effects: an RSA study of 33 primary total hip arthroplasties followed for up to ten years. Bone Joint J 2014; 96-B:604-8. [PMID: 24788493 DOI: 10.1302/0301-620x.96b5.33580] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In 2005, we demonstrated that the polished triple-tapered C-stem at two years had migrated distally and rotated internally. From that series, 33 patients have now been followed radiologically, clinically and by radiostereometric analysis (RSA) for up to ten years. The distal migration within the cement mantle had continued and reached a mean of 2 mm (0.5 to 4.0) at ten years. Internal rotation, also within the cement mantle, was a mean 3.8° (external 1.6° to internal 6.6°) The cement mantle did not show any sign of migration or loosening in relation to the femoral bone. There were no clinical or radiological signs indicating that the migration or rotation within the cement mantle had had any adverse effects for the patients.
Collapse
Affiliation(s)
- T von Schewelov
- Skane University Hospital, Department of Orthopaedics, S-205 02 Malmö, Sweden
| | | | | | | |
Collapse
|
45
|
Nysted M, Foss OA, Klaksvik J, Benum P, Haugan K, Husby OS, Aamodt A. Small and similar amounts of micromotion in an anatomical stem and a customized cementless femoral stem in regular-shaped femurs. A 5-year follow-up randomized RSA study. Acta Orthop 2014; 85:152-8. [PMID: 24650024 PMCID: PMC3967257 DOI: 10.3109/17453674.2014.899846] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE High primary stability is important for long-term survival of uncemented femoral stems. Different stem designs are currently in use. The ABG-I is a well-documented anatomical stem with a press-fit design. The Unique stem is designed for a tight customized fit to the cortical bone of the upper femur. This implant was initially developed for patients with abnormal anatomy, but the concept can also be used in patients with normal femoral anatomy. We present 5-year radiostereometric analysis (RSA) results from a randomized study comparing the ABG-I anatomical stem with the Unique femoral stem. PATIENTS AND METHODS 100 hips with regular upper femur anatomy were randomized to either the ABG-I stem or the Unique femoral stem. RSA measurements were performed postoperatively and after 3, 6, 12, 24, and 60 months. RESULTS RSA measurements from 80 hips were available for analysis at the 5-year follow-up. Small amounts of movement were observed for both stems, with no statistically significant differences between the 2 types. INTERPRETATION No improvement in long-term stability was found from using a customized stem design. However, no patients with abnormal geometry of the upper femur were included in this study.
Collapse
Affiliation(s)
- Mona Nysted
- Orthopaedic Research Centre, Department of Orthopaedic Surgery, Trondheim University Hospital
| | - Olav A Foss
- Orthopaedic Research Centre, Department of Orthopaedic Surgery, Trondheim University Hospital,Department of Neuroscience, Norwegian University of Science and Technology, Trondheim
| | - Jomar Klaksvik
- Orthopaedic Research Centre, Department of Orthopaedic Surgery, Trondheim University Hospital
| | - Pål Benum
- Orthopaedic Research Centre, Department of Orthopaedic Surgery, Trondheim University Hospital,Department of Neuroscience, Norwegian University of Science and Technology, Trondheim
| | - Kristin Haugan
- Orthopaedic Research Centre, Department of Orthopaedic Surgery, Trondheim University Hospital
| | - Otto Schnell Husby
- Orthopaedic Research Centre, Department of Orthopaedic Surgery, Trondheim University Hospital
| | - Arild Aamodt
- Department of Neuroscience, Norwegian University of Science and Technology, Trondheim,Department of Orthopaedics, Lovisenberg Deaconal Hospital, Oslo, Norway.
| |
Collapse
|
46
|
Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up. INTERNATIONAL ORTHOPAEDICS 2013; 38:717-24. [PMID: 24352821 DOI: 10.1007/s00264-013-2186-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2013] [Accepted: 11/03/2013] [Indexed: 10/25/2022]
Abstract
PURPOSE The aim of this study was to determine outcomes of total hip replacement (THR) with the Lemania cemented femoral stem. METHODS A total of 78 THR patients were followed and compared to 17 "fit", healthy, elderly and 72 "frail" elderly subjects without THR, using clinical outcome measures and a portable, in-field gait analysis device at five and ten years follow-up. RESULTS Forty-one patients (53%), mean age 83.4 years, available at ten years follow-up, reported very good to excellent satisfaction. Mean Harris Hip and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were 81.2 and 10.5 points, respectively, with excellent radiological preservation of proximal femur bone stock. Spatial and temporal gait parameters were close to the fit group and better than the frail group. CONCLUSIONS Lemania THR demonstrated very good, stable clinical and radiological results at ten years in an older patient group, comparable to other cemented systems for primary THR. Gait analysis confirmed good walking performance in a real-life environment.
Collapse
|
47
|
Kärrholm J. Radiostereometric analysis of early implant migration - a valuable tool to ensure proper introduction of new implants. Acta Orthop 2012; 83:551-2. [PMID: 23126576 PMCID: PMC3555445 DOI: 10.3109/17453674.2012.745352] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
|
48
|
|