1
|
Blum P, Neugebauer J, Keiler A, Putzer D, Watrinet J, Regenbogen S, Dammerer D. Mid-Term Migration Pattern of a Cemented Collared Anatomical Stem-A Retrospective Study Using EBRA-FCA. J Clin Med 2024; 13:5187. [PMID: 39274400 PMCID: PMC11396155 DOI: 10.3390/jcm13175187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 08/16/2024] [Accepted: 08/19/2024] [Indexed: 09/16/2024] Open
Abstract
Background: Aseptic loosening is one of the leading causes of stem revision. Einzel Bild Röntgen Analyse-Femoral Component Analysis allows for the detection of distal stem migration, which is used as a predictive factor for implant longevity. This study aims to demonstrate the migration behavior of a cemented collared anatomical stem. Methods: This study retrospectively examined all patients who received a cemented Lubinus SP II stem (Waldemar Link, Hamburg, Germany) between 2003 and 2019. We used the EBRA-FCA software (University of Innsbruck, Austria) to determine the migration patterns and thoroughly examined the patients' medical histories. In addition, the potential influence of femoral configuration and BMI on the migration behavior was assessed. Results: This study included 61 patients (48 females and 13 males) with a total of 61 stems that met our inclusion criteria. The mean age at surgery was 76 years (ranging from 30 to 93 years). According to EBRA-FCA migration analysis, a median subsidence of 0.7 mm was observed at 24 months and at the final follow-up (median 78 months). Distal stem migration was significantly higher at the 6-month time point in patients with Dorr type A femurs compared to Dorr type B femurs (p = 0.016). Body mass index (BMI) had no significant effect on stem migration. Conclusions: The measured subsidence of the Lubinus SP 2 stem using EBRA-FCA was below established thresholds, indicating excellent long-term outcomes. Although there was significantly increased subsidence in Dorr type A femurs during the initial 6 months, thereafter, no statistically significant difference was observed compared to Dorr type B femurs.
Collapse
Affiliation(s)
- Philipp Blum
- Department of Trauma Surgery, BG Trauma Center Murnau, 82418 Murnau, Germany
| | - Johannes Neugebauer
- Department of Orthopaedics and Traumatology, Krems University Hospital, 3500 Krems, Austria
- Karl Landsteiner Private University for Health Sciences, 3500 Krems, Austria
| | - Alexander Keiler
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | - David Putzer
- Department of Experimental Orthopaedics, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | - Julius Watrinet
- Department of Orthopaedic Sports Medicine, Technical University of Munich, 81675 Munich, Germany
| | - Stephan Regenbogen
- Department of Traumatology, BG Trauma Center Ludwigshafen, University of Heidelberg, 67071 Ludwigshafen, Germany
| | - Dietmar Dammerer
- Department of Orthopaedics and Traumatology, Krems University Hospital, 3500 Krems, Austria
- Karl Landsteiner Private University for Health Sciences, 3500 Krems, Austria
| |
Collapse
|
2
|
Rele S, O'Bryan E, Holder C, Lewis PL, Di Bella C. Collared Cementless Femoral Components Reduce the Revision Rates in Primary Total Hip Arthroplasty Using the Direct Anterior Approach: An Australian Orthopaedic Association National Joint Replacement Registry Study. J Arthroplasty 2024; 39:S340-S346.e2. [PMID: 38735543 DOI: 10.1016/j.arth.2024.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 04/30/2024] [Accepted: 05/01/2024] [Indexed: 05/14/2024] Open
Abstract
BACKGROUND An increased risk of periprosthetic fracture and aseptic loosening is reported when the direct anterior approach (DAA) is used for total hip arthroplasty (THA), especially with cementless implants. We assessed the rate of revision comparing collared and collarless femoral stems when using the DAA for THA. METHODS We used data from the Australian Orthopaedic Association National Joint Replacement Registry for primary THA for osteoarthritis inserted with the DAA between January 2015 and December 2022. There were 48,567 THAs that used the DAA (26,690 collarless cementless, 10,161 collared cementless, and 11,716 cemented). Cumulative percent revision was calculated for all-cause revision, revision for periprosthetic femoral fractures, and aseptic femoral stem loosening. Cox proportional hazard ratios [HRs] were used to compare the revision of collared and collarless cementless stems. We also compared collared cementless stems and cemented stems. RESULTS A higher rate of all-cause revision within 3 months of surgery was observed with collarless compared to collared cementless implants (HR: 1.99 [95% confidence interval (CI), 1.56 to 2.54]; P < .001). Similarly, collarless cementless implants were associated with a greater rate of revision for fracture in the first 6 months (HR: 2.90 [95% CI, 1.89 to 4.45]; P < .001) and after 6 months (HR 10.04 [95% CI 1.38 to 73.21]; P = .02), as well as an increased rate of revision for aseptic loosening after 2 years (HR: 5.76 [95% CI, 1.81 to 18.28], P = .003). Collared cementless and cemented stems performed similarly. CONCLUSION Collared stems were associated with a reduced rate of all-cause revision for cementless THA performed via the DAA. The reduction in risk may be due to protection from periprosthetic femoral fracture and aseptic loosening.
Collapse
Affiliation(s)
- Siddharth Rele
- Department of Surgery, St Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia
| | - Edward O'Bryan
- Orthopaedic Department, Alfred Health, Melbourne, Victoria, Australia
| | - Carl Holder
- South Australian Health and Medical Research Institute (SAHMRI), Adelaide, South Australia, Australia
| | - Peter L Lewis
- Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), Adelaide, South Australia, Australia; University of Adelaide Medical School, Adelaide, South Australia, Australia
| | - Claudia Di Bella
- Department of Surgery, The University of Melbourne, Eastern Hill Campus, Fitzroy, Victoria, Australia; Department of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia; Victorian Bone and Joint Specialists, Fitzroy, Victoria, Australia
| |
Collapse
|
3
|
Ling CSY, Izmin A, Todo M, Merican AM, Chong DYR. Proximal cementation of a collarless polished tapered hip stem: biomechanical analysis using a validated finite element model. Med Biol Eng Comput 2024:10.1007/s11517-024-03152-6. [PMID: 38898201 DOI: 10.1007/s11517-024-03152-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Accepted: 06/08/2024] [Indexed: 06/21/2024]
Abstract
Total hip replacement (THR) with cemented stem is a common procedure for patients with hip osteoarthritis. When primary THR fails, removal of the cement is problematic and poses challenges during revision surgeries. The possibility of proximal partial cementing of the hip stem was explored to mitigate the problem. 3D finite element analysis was performed to investigate the feasibility of reduced cement length for effective implant fixation and load transmission. Three levels of cement reduction (40 mm, 80 mm, and 100 mm) in the femoral stem were evaluated. All models were assigned loadings of peak forces acting on the femur during walking and stair climbing. The experimental and predicted max/min principal bone strains were fitted into regression models and showed good correlations. FE results indicated stress increment in the femoral bone, stem, and cement due to cement reduction. A notable increase of bone stress was observed with large cement reduction of 80-100 mm, particularly in Gruen zones 3 and 5 during walking and Gruen zones 3 and 6 during stair climbing. The increase of cement stresses could be limited to 11% with a cement reduction of 40 mm. The findings suggested that a 40-mm cement reduction in hip stem fixation was desirable to avoid unwanted complications after cemented THR.
Collapse
Affiliation(s)
- Carol Sze Yee Ling
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Aiman Izmin
- Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka, Japan
| | - Mitsugu Todo
- Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka, Japan
- Research Institute for Applied Mechanics, Kyushu University, Fukuoka, Japan
| | - Azhar M Merican
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Desmond Y R Chong
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
- Engineering Cluster, Singapore Institute of Technology, 10 Dover Drive, Singapore, 138683, Singapore.
| |
Collapse
|
4
|
Angelomenos V, Mohaddes M, Kärrholm J, Malchau H, Shareghi B, Itayem R. A prospective randomized study of Refobacin Bone Cement R versus Palacos R + G. Bone Joint J 2024; 106-B:435-441. [PMID: 38688480 DOI: 10.1302/0301-620x.106b5.bjj-2023-0999.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
Aims Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures. Methods Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected. Results Median distal migration (y-axis) at two years for the Refobacin-Optivac system was -0.79 mm (-2.01 to -0.09), for the Refobacin-Optipac system was -0.75 mm (-2.16 to 0.20), and for the Palacos-Optivac system was -1.01 mm (-4.31 to -0.29). No statistically significant differences were found between the groups. Secondary outcomes did not differ statistically between the groups at the two-year follow-up. Conclusion At two years, we found no significant differences in distal migration or clinical outcomes between the three groups. Our data indicate that Refobacin Bone Cement R and Palacos R + G are comparable in terms of stable fixation and early clinical outcomes.
Collapse
Affiliation(s)
- Vasileios Angelomenos
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Hand Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maziar Mohaddes
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Johan Kärrholm
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Henrik Malchau
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Bita Shareghi
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Raed Itayem
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
5
|
Srikrishnaraj A, Lanting BA, Burton JP, Teeter MG. The Microbial Revolution in the World of Joint Replacement Surgery. JB JS Open Access 2024; 9:e23.00153. [PMID: 38638595 PMCID: PMC11023614 DOI: 10.2106/jbjs.oa.23.00153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/20/2024] Open
Abstract
Background The prevalence of revision surgery due to aseptic loosening and periprosthetic joint infection (PJI) following total hip and knee arthroplasty is growing. Strategies to prevent the need for revision surgery and its associated health-care costs and patient morbidity are needed. Therapies that modulate the gut microbiota to influence bone health and systemic inflammation are a novel area of research. Methods A literature review of preclinical and clinical peer-reviewed articles relating to the role of the gut microbiota in bone health and PJI was performed. Results There is evidence that the gut microbiota plays a role in maintaining bone mineral density, which can contribute to osseointegration, osteolysis, aseptic loosening, and periprosthetic fractures. Similarly, the gut microbiota influences gut permeability and the potential for bacterial translocation to the bloodstream, increasing susceptibility to PJI. Conclusions Emerging evidence supports the role of the gut microbiota in the development of complications such as aseptic loosening and PJI after total hip or knee arthroplasty. There is a potential for microbial therapies such as probiotics or fecal microbial transplantation to moderate the risk of developing these complications. However, further investigation is required. Clinical Relevance Modulation of the gut microbiota may influence patient outcomes following total joint arthroplasty.
Collapse
Affiliation(s)
- Arjuna Srikrishnaraj
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
| | - Brent A. Lanting
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
- Bone and Joint Institute, Western University, London, Ontario, Canada
| | - Jeremy P. Burton
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
- Bone and Joint Institute, Western University, London, Ontario, Canada
| | - Matthew G. Teeter
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
- Bone and Joint Institute, Western University, London, Ontario, Canada
| |
Collapse
|
6
|
Migliorini F, Maffulli N, Pilone M, Velaj E, Hofmann UK, Bell A. Demographic characteristics influencing the stem subsidence in total hip arthroplasty: an imaging study. Arch Orthop Trauma Surg 2024; 144:887-894. [PMID: 37770626 PMCID: PMC10822810 DOI: 10.1007/s00402-023-05054-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 09/02/2023] [Indexed: 09/30/2023]
Abstract
INTRODUCTION The present study evaluated whether patient demographic characteristics influence the subsidence of the stem in total hip arthroplasty (THA). The following characteristics were evaluated: age, height, weight, and sex. The association between the time elapsed from the THA implantation and the amount of stem subsidence was also investigated. METHODS The records of patients who underwent THA in the period between 2016 and 2023 were accessed. All patients underwent two-staged bilateral THA using cementless DePuy collarless Corail (DePuy Synthes, Raynham, MA, USA) stems. The following parameters were measured and compared to assess stem subsidence: distance from the proximal femur at the stem bone interface and the medial apex of the regular triangle built within the trochanter minor (point A); distance from the medial apex of the regular triangle built within the trochanter minor and the distal portion of the femoral stem (point B). RESULTS Overall, 294 patients were included. 62% (182 of 294 patients) were women. 45% (134 of 296 THAs) were on the right side. The mean age was 64.9 ± 10.4 years. The mean BMI was 28.3 ± 5.1 kg/m2. The mean length of the follow-up was 14.4 ± 11.0 months. The mean subsidence in point A was 2.1 mm (P < 0.0001), and that in point B was 3.1 mm (P < 0.0001). There was evidence of a weak positive association between patient weight (P < 0.0001), age (P = 0.03), follow-up (P = 0.002) and the amount of stem subsidence. Patient height did not demonstrate any association with the amount of stem subsidence (P = 0.07). There was no difference in stem subsidence between women and men (P = 0.9). CONCLUSION Stem subsidence in THA using cementless DePuy collarless Corail implants is approximately 2.6 mm after 14.4 months. Greater patient weight, age, and longer time elapsed from THA implantation were associated with greater stem subsidence. Patient height and sex did not demonstrate any influence on the amount of stem subsidence. These results must be considered in light of the limitations of the present study.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany.
- Department of Orthopaedics and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of Paracelsus Medical University (PMU), 39100 Bolzano, Italy.
| | - Nicola Maffulli
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- School of Pharmacy and Bioengineering, Keele University School of Medicine, Thornburrow Drive, Stoke On Trent, England
- Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, Queen Mary University of London, 275 Bancroft Road, London, E1 4DG, England
| | - Marco Pilone
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Erlis Velaj
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany
| | - Ulf Krister Hofmann
- Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Clinic Aachen, RWTH Aachen University Medical Centre, Pauwelsstraße 30, 52064, Aachen, Germany
| | - Andreas Bell
- Department of Orthopedics, Eifelklinik St. Brigida, 52152, Simmerath, Germany
| |
Collapse
|
7
|
Lübbeke A, Barea C, Zingg M, Lauper N, Hannouche D, Garavaglia G. Radiographic signs and hip pain 5 years after THA with a cemented stem predict future revision for aseptic loosening: a prospective cohort study. Acta Orthop 2024; 95:32-38. [PMID: 38284749 PMCID: PMC10823869 DOI: 10.2340/17453674.2023.26190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Accepted: 11/02/2023] [Indexed: 01/30/2024] Open
Abstract
BACKGROUND AND PURPOSE We aimed to evaluate the long-term predictive value of radiographic abnormality and/or hip pain assessed 5 years following primary total hip arthroplasty (THA) and the occurrence of revision for aseptic loosening between 5 and 25 years postoperatively. PATIENTS AND METHODS We included all primary THAs performed between 1996 and 2011 (same uncemented cup, polyethylene-ceramic bearing, 28 mm head, cemented stem) and prospectively enrolled in the institutional registry, for whom baseline and follow-up radiographs were available. At 5 years radiographically we assessed femoral osteolysis and/or stem migration. Pain was evaluated with the Harris Hip pain subscore. Kaplan-Meier survival and Cox regression analyses were performed. RESULTS 1,317 primary THAs were included. 25 THAs (2%) were revised for aseptic stem loosening. Any abnormal radiographic sign at 5 years was present in 191 THAs (14%). Occasional hip pain was reported by 20% and slight to severe pain by 12% of patients at 5 years. In patients < 60 years, 10 of the 12 later revised for aseptic stem loosening had abnormal radiographs at 5 years vs. 5 of the 13 later revised in those ≥ 60 years. Hazard ratios (HR) were 34 (95% confidence interval [CI] 7-155) in younger vs. 4 (CI 1-11) in the older group. HR for association of hip pain at 5 years with future revision was 3 (CI 1-5). CONCLUSION The presence of abnormal radiographic signs 5 years after THA was strongly associated with later revision for aseptic stem loosening, especially in patients < 60 years. The association between pain at 5 years and future revision was much weaker.
Collapse
Affiliation(s)
- Anne Lübbeke
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, University of Geneva, Faculty of Medicine, Geneva, Switzerland; Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK.
| | - Christophe Barea
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, University of Geneva, Faculty of Medicine, Geneva, Switzerland
| | - Matthieu Zingg
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, University of Geneva, Faculty of Medicine, Geneva, Switzerland
| | - Nicolas Lauper
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, University of Geneva, Faculty of Medicine, Geneva, Switzerland
| | - Didier Hannouche
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, University of Geneva, Faculty of Medicine, Geneva, Switzerland
| | | |
Collapse
|
8
|
Panez-Toro I, Heymann D, Gouin F, Amiaud J, Heymann MF, Córdova LA. Roles of inflammatory cell infiltrate in periprosthetic osteolysis. Front Immunol 2023; 14:1310262. [PMID: 38106424 PMCID: PMC10722268 DOI: 10.3389/fimmu.2023.1310262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/19/2023] Open
Abstract
Classically, particle-induced periprosthetic osteolysis at the implant-bone interface has explained the aseptic loosening of joint replacement. This response is preceded by triggering both the innate and acquired immune response with subsequent activation of osteoclasts, the bone-resorbing cells. Although particle-induced periprosthetic osteolysis has been considered a foreign body chronic inflammation mediated by myelomonocytic-derived cells, current reports describe wide heterogeneous inflammatory cells infiltrating the periprosthetic tissues. This review aims to discuss the role of those non-myelomonocytic cells in periprosthetic tissues exposed to wear particles by showing original data. Specifically, we discuss the role of T cells (CD3+, CD4+, and CD8+) and B cells (CD20+) coexisting with CD68+/TRAP- multinucleated giant cells associated with both polyethylene and metallic particles infiltrating retrieved periprosthetic membranes. This review contributes valuable insight to support the complex cell and molecular mechanisms behind the aseptic loosening theories of orthopedic implants.
Collapse
Affiliation(s)
- Isidora Panez-Toro
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Dominique Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
- The University of Sheffield, Dept of Oncology and Metabolism, Sheffield, United Kingdom
| | - François Gouin
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Jérôme Amiaud
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
| | - Marie-Françoise Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Luis A. Córdova
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile
- Oral and Maxillofacial Surgery, Clínica MEDS, Santiago, Chile
| |
Collapse
|
9
|
Puijk R, Puijk RH, Laende EK, Dunbar MJ, Plevier JWM, Nolte PA, Pijls BGCW. 6-month migration sufficient for evaluation of total knee replacements: a systematic review and meta-analysis. Acta Orthop 2023; 94:577-587. [PMID: 38038237 PMCID: PMC10690979 DOI: 10.2340/17453674.2023.24579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Accepted: 10/22/2023] [Indexed: 12/02/2023] Open
Abstract
BACKGROUND AND PURPOSE This updated meta-analysis evaluates the migration pattern of the tibial component of primary total knee replacements measured with radiostereometric analysis (RSA). We aimed to evaluate whether 6-month maximum total point motion (MTPM) values could be used instead of 1-year MTPM for RSA threshold testing and to present the pooled migration patterns for different implant designs that can be used as a benchmark. PATIENTS AND METHODS The search included all published RSA studies on migration patterns of tibial components until 2023. Study groups were classified according to their prosthesis brand, fixation, and insert (PFI). Sub-analyses were performed to compare the mean tibial component migration patterns of different implant variables, stratified according to fixation. RESULTS 96 studies (43 new studies), including 197 study groups and 4,706 knees, were included. Most migration occurred within the first 6 postoperative months (126 study groups: mean 0.58 mm, 95% confidence interval [CI] 0.50-0.65), followed by minimal migration between 6 and 12 months (197 study groups: mean 0.04 mm, CI 0.03-0.06), irrespective of the fixation method used. Distinct migration patterns were observed among the different fixation methods. No differences were found in migration patterns among cemented components in any of the sub-group analyses conducted. For uncemented implants, trabecular metal surfaced components seemed to migrate less than porous-coated or uncoated components Conclusion: Based on the small difference between MTPM values at 6 months and 1 year, MTPM at 6 months could be used instead of MTPM at 1 year for RSA threshold testing. The pooled migration patterns can be used as benchmark for evaluation of new implants by defining fixation-specific RSA thresholds when combined with implant survival.
Collapse
Affiliation(s)
- Raymond Puijk
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands.
| | - Rowan H Puijk
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - Elise K Laende
- Mechanical and Materials Engineering, Queen's University, Kingston, Ontario, Canada; Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Michael J Dunbar
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - José W M Plevier
- Walaeus Library, Leiden University Medical Center, Leiden, The Netherlands
| | - Peter A Nolte
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands; Department of Oral Cell Biology, Academic Centre for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Bart G C W Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
10
|
Oe K, Iida H, Hirata M, Kawamura H, Ueda N, Nakamura T, Okamoto N, Saito T. An atypical periprosthetic fracture in collarless, polished, tapered, cemented stems of total hip arthroplasty: A report of five SC-stem cases and literature review. J Orthop Sci 2023; 28:1422-1429. [PMID: 34045138 DOI: 10.1016/j.jos.2021.04.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 03/29/2021] [Accepted: 04/02/2021] [Indexed: 10/21/2022]
Affiliation(s)
- Kenichi Oe
- Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan.
| | - Hirokazu Iida
- Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Masayuki Hirata
- Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Hiroshi Kawamura
- Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Narumi Ueda
- Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Tomohisa Nakamura
- Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Naofumi Okamoto
- Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Takanori Saito
- Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| |
Collapse
|
11
|
Turgeon TR, Righolt CH, Burnell CD, Gascoyne TC, Hedden DR, Bohm ER. Comparison of two hydroxyapatite-coated femoral components: a randomized clinical trial using radiostereometric analysis. Bone Joint J 2023; 105-B:1045-1051. [PMID: 37782569 DOI: 10.1302/0301-620x.105b10.bjj-2023-0427.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Aims The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components. Methods Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020. Radiostereometric analysis examinations at six, 12, and 24 months were used to assess the migration of each implanted femoral component compared to a baseline assessment. Patient-reported outcome measures were also recorded for these same timepoints. Overall, 50 patients were enrolled (62% male (n = 31), with a mean age of 65.7 years (SD 7.3), and mean BMI of 30.2 kg/m2 (SD 5.2)). Results The two-year subsidence was similar for Avenir (-0.018 mm (95% confidence interval (CI) -0.053 to 0.018) and Corail (0.000 mm (95% CI -0.027 to 0.026; p = 0.428). Both anteversion/retroversion (Avenir 0.139° (95% CI -0.204 to 0.481°); Corail -0.196° (95% CI -0.445 to 0.053°; p = 0.110) and varus/valgus tilt (Avenir -0.024° (95% CI -0.077 to 0.028); Corail -0.049° (95% CI -0.098 to 0.000°; p = 0.473) were not statistically significantly different. After two years, patients reported similar improvements in EuroQol five-dimension five-level health questionnaire (Avenir 0.22 (SD 0.2); Corail 0.22 (SD 0.18); p = 0.965) and other outcomes scores. Patient satisfaction on a five-point Likert scale was also similar between both groups after two years (Avenir 1.38 (SD 0.88); Corail 1.33 (SD 0.57); p = 0.846). Conclusion The performance of both femoral components was similar in terms of stability and patient outcomes.
Collapse
Affiliation(s)
- Thomas R Turgeon
- Concordia Joint Replacement Group, Winnipeg, Canada
- Department of Surgery, University of Manitoba, Winnipeg, Canada
| | - Christiaan H Righolt
- Concordia Joint Replacement Group, Winnipeg, Canada
- Orthopaedic Innovation Centre, Winnipeg, Canada
| | - Colin D Burnell
- Concordia Joint Replacement Group, Winnipeg, Canada
- Department of Surgery, University of Manitoba, Winnipeg, Canada
| | | | - David R Hedden
- Concordia Joint Replacement Group, Winnipeg, Canada
- Department of Surgery, University of Manitoba, Winnipeg, Canada
| | - Eric R Bohm
- Concordia Joint Replacement Group, Winnipeg, Canada
- Department of Surgery, University of Manitoba, Winnipeg, Canada
| |
Collapse
|
12
|
Hennicke NS, Kluess D, Sander M. Influence of stem design parameters on periprosthetic femoral fractures examined by subject specific finite element analyses. Med Eng Phys 2023; 119:104032. [PMID: 37634909 DOI: 10.1016/j.medengphy.2023.104032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 07/12/2023] [Accepted: 07/24/2023] [Indexed: 08/29/2023]
Abstract
Due to the increasing number of periprosthetic femoral fractures (PFF), the optimisation of implant design gains importance. For the presented research a validated, subject specific finite element model of a human femur with an inlying total hip stem was used to compare the influence of different geometrical implant parameters on the development of PFF. The heterogeneous bone tissue was modelled on the basis of computed tomography scans. A ductile damage model with element deletion was applied to simulate bone fracture in a load case re-enacting a stumbling scenario. The results were compared in terms of fracture load, subsidence and fracture pattern to analyse the influence of friction at the implant-bone interface, implant size and stem length. The results showed that higher friction coefficients lead to an increase of fracture load. Also, the usage of an oversized implant has a negligible effect while an undersized implant reduces the fracture load by 48.9% for the investigated femur. Lastly, a higher fracture load was reached with an elongated stem, but the bending and change in fracture path indicate a more distal force transmission and subsequent stress shielding in the proximal femur.
Collapse
Affiliation(s)
- N S Hennicke
- Institute of Structural Mechanics, University of Rostock, Albert-Einstein-Str. 2, Rostock 18059, Germany.
| | - D Kluess
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - M Sander
- Institute of Structural Mechanics, University of Rostock, Albert-Einstein-Str. 2, Rostock 18059, Germany
| |
Collapse
|
13
|
Haugan K, Foss OA, Husby OS, Husby VS, Svenningsen S, Winther SB. Surgical approach had minor association with femoral stem migration in total hip arthroplasty: radiostereometric analysis of 61 patients after 5-year follow-up. Acta Orthop 2023; 94:410-415. [PMID: 37563924 PMCID: PMC10416221 DOI: 10.2340/17453674.2023.18264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 06/19/2023] [Indexed: 08/12/2023] Open
Abstract
BACKGROUND AND PURPOSE Total hip arthroplasty (THA) is usually performed using 1 of 3 surgical approaches: direct lateral (DLA), posterior (PA), or anterior (AA). AA is different from DLA and PA owing to limited intraoperative visibility of the femoral canal. This could affect stem positioning and therefore migration. We aimed to perform an exploratory radiostereometric analysis (RSA) study with 3 groups for surgical approach assessing stem migration up to 5 years postoperatively. PATIENTS AND METHODS 61 patients with unilateral osteoarthritis of the hip were included. 21 patients were allocated to the DLA, 20 to the PA, and 20 to the AA group. All patients received an uncemented, collarless, double-tapered, fully hydroxyapatite-coated Profemur Gladiator stem. Migration was measured with model-based RSA. Baseline RSA was on day 1 postoperatively. The follow-ups were at day 8, at 5 weeks, and at 3, 6, 12, 24, and 60 months after surgery. Generalized linear mixed models were used to analyze maximum total point motion (MTPM) migrations. RESULTS Group mean differences in MTPM were 0.4 mm (95% confidence interval [CI] -1.5 to 2.4) for DLA vs. PA, 1.1 mm (CI -1.0 to 3.3) for AA vs. DLA, and 1.6 mm (CI -0.8 to 3.9) for AA vs. PA, when adjusted for sex and age as covariates. 2 stems in the AA group had excessive early migration. For all stems the migrations occurred mainly within 5-week follow-up and then stabilized. CONCLUSION At 5-year follow-up, there were no statistically significant differences in stem migration associated with the 3 surgical approaches used in this study.
Collapse
Affiliation(s)
- Kristin Haugan
- Department of Orthopaedic Surgery, St Olavs Hospital HF, Trondheim.
| | - Olav A Foss
- Department of Orthopaedic Surgery, St Olavs Hospital HF, Trondheim; Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Trondheim
| | - Otto S Husby
- Department of Orthopaedic Surgery, St Olavs Hospital HF, Trondheim; Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Trondheim
| | - Vigdis S Husby
- Department of Orthopaedic Surgery, St Olavs Hospital HF, Trondheim; Department of Health Sciences Aalesund, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Aalesund
| | | | - Siri B Winther
- Department of Orthopaedic Surgery, St Olavs Hospital HF, Trondheim
| |
Collapse
|
14
|
Fontalis A, Kayani B, Vanhegan I, Tahmassebi J, Haddad IC, Giebaly DE, Rajput V, Hansjee S, Haddad FS. 2-Year Radiostereometric Analysis Evaluation of a Short, Proximally Coated, Triple-Taper Blade Femoral Stem Versus a Quadrangular-Taper Stem With Reinforced Proximal Body: A Randomized Controlled Trial. J Arthroplasty 2023:S0883-5403(23)00242-5. [PMID: 36931355 DOI: 10.1016/j.arth.2023.03.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 03/02/2023] [Accepted: 03/05/2023] [Indexed: 03/19/2023] Open
Abstract
BACKGROUND Cementless stem designs with proximal metaphyseal fixation aim to achieve better load distribution, reduce stress shielding, and improve primary stability. The purpose of this prospective, randomized controlled trial was to evaluate the 2-year migration and clinical outcomes of two cementless femoral stems. METHODS A total of 60 participants undergoing primary total hip arthroplasty for any cause were randomly allocated to receiving either a proximally coated, short blade stem or a quadrangular-taper stem with a reinforced proximal body. Radiostereometric Analysis (RSA) radiographs were performed post-operatively and at 6 weeks, 6 months, 1- and 2-years. The Harris Hip Score, Oxford Hip Score and the EuroQol five-dimension (EQ5D) were also collected. RESULTS At two years, the median subsidence of the short-blade stem was 0.097 millimeters (mm) [Interquartile range (IQR) -0.67 to 0.08)] versus 0.086 mm(IQR, -0.29 to 0.005, P=0.683); medial translation 0.023 mm (IQR 0.08 to 0.12) versus 0.029 mm(IQR -0.07 to 0.10, P=0.907); anterior translation 0.035 mm (IQR -0.23 to 0.33) versus 0.07 mm (IQR -0.13 to 0.08, P=0.268). At 24 months postoperatively, there were no stem revisions and Patient Reported Outcome Measures (PROMs) were comparable between groups. CONCLUSION Both cementless stems exhibited a predictable migration pattern and achieved initial stability. There was no difference in migration across the three Cartesian axes at any timepoint. Clinical outcomes and PROMs were also comparable. Biological fixation of both implants evidenced by the RSA and excellent PROMs are likely to translate to longer-term stability, which would need to be corroborated by longer-term outcome studies.
Collapse
Affiliation(s)
- Andreas Fontalis
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom; Division of Surgery and Interventional Science, University College London, Gower Street, London, WC1E 6BT, UK.
| | - Babar Kayani
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom
| | - Ivor Vanhegan
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom
| | - Jenni Tahmassebi
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom
| | - Isabella Catrina Haddad
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom
| | - Dia Eldean Giebaly
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom; Division of Surgery and Interventional Science, University College London, Gower Street, London, WC1E 6BT, UK
| | - Vishal Rajput
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom
| | - Shanil Hansjee
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom
| | - Fares S Haddad
- Department of Trauma and Orthopaedic Surgery, University College Hospital, London, United Kingdom; Division of Surgery and Interventional Science, University College London, Gower Street, London, WC1E 6BT, UK
| |
Collapse
|
15
|
Clarke SG, Logishetty K, Halewood C, Cobb JP. Low dose CT-based spatial analysis (CTSA) to measure implant migration after ceramic hip resurfacing arthroplasty (HRA): A phantom study. Proc Inst Mech Eng H 2023; 237:359-367. [PMID: 36772975 PMCID: PMC10052406 DOI: 10.1177/09544119231153905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
Implant migration is a predictor of arthroplasty survivorship. It is crucial to monitor the migration of novel hip prostheses within premarket clinical investigations. RSA is the gold standard method, but requires calibrated radiographs using specialised equipment. A commercial computed tomography micromotion analysis solution is a promising alternative but is not yet available for use with monobloc ceramic implants. This study aimed to develop and validate a CT-based spatial analysis (CTSA) method for use with ceramic implants. A phantom study was undertaken to assess accuracy and precision. A ceramic hip resurfacing arthroplasty (HRA) and 20 tantalum beads were implanted into a synthetic hip model and mounted onto a 6-degree of freedom motion stage. The hip was repeatedly scanned with a low dose CT protocol, with imposed micromovements. Data were interrogated using a semiautomated technique. The effective radiation dose for each scan was estimated to be 0.25 mSv. For the head implant, precision ranged between 0.11 and 0.28 mm for translations and 0.34°-0.42° for rotations. For the cup implant, precision ranged between 0.08 and 0.11 mm and 0.19° and 0.42°. For the head, accuracy ranged between 0.04 and 0.18 mm for translations and 0.28°-0.46° for rotations. For the cup, accuracy ranged between 0.04 and 0.08 mm and 0.17° and 0.43°. This in vitro study demonstrates that low dose CTSA of a ceramic HRA is similar in accuracy to RSA. CT is ubiquitous, and this method may be an alternative to RSA to measure prosthesis migration.
Collapse
Affiliation(s)
- Susannah G Clarke
- MSk Lab, Imperial College London, London, UK.,Embody Orthopaedic Limited, London
| | | | | | | |
Collapse
|
16
|
van der Voort P, van Delft D, Valstar ER, Kaptein BL, Fiocco M, Nelissen RGHH. Migration behaviour of 2 clinically excellent cementless stems with different design rationales: 5-year follow-up of a randomised RSA-study. Hip Int 2022; 32:747-758. [PMID: 33596116 PMCID: PMC9726743 DOI: 10.1177/1120700021995482] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Excellent long-term survival has been reported for both the Taperloc and the Mallory-Head cementless stems. However, little is known about the migration behaviour of these stems which have different design rationales. The purpose of this randomised clinical trial was to compare the migration and clinical outcomes of these stems during 5 years of follow-up. METHODS 42 consecutive hips in 38 patients scheduled to receive cementless THA were randomised to either a Taperloc or a Mallory-Head stem. Evaluation took place preoperatively and postoperatively on the second day, at 6, 12, 26, and 52 weeks, and annually thereafter. Primary outcome was stem migration measured using roentgen stereophotogrammetric analysis (RSA) and secondary outcomes were the Harris Hip Score (HHS) and 36-Item Short-Form Health Survey (SF-36). No patients were lost to follow-up; in 1 patient the THA was removed due to deep infection 3 months postoperatively. In 6 hips migration measurements were not possible due to insufficient marker configuration. RESULTS Throughout the follow-up period of 5 years, 3-dimensional migration was comparable between the Taperloc and the Mallory-Head stems (p-values > 0.05). However, at the 5-year follow-up point the retroversion of the Mallory-Head stem was 0.9° more than the Taperloc stem (p = 0.04). Initial subsidence and retroversion were respectively as large as 6.8 mm and 3.6° for the Taperloc stem and 5 mm and 3.6° for the Mallory-Head stem. After the first postoperative year, both implants had stabilised. The mean increment of HHS, as well as the SF-36 scores during the 5-year follow-up, were comparable between the 2 stems. CONCLUSIONS The excellent long-term survival of both designs was confirmed in this study showing comparable initial migration with subsequent stabilisation. However, the Taperloc design with a flat, wedged geometry showed better rotational stability.
Collapse
Affiliation(s)
- Paul van der Voort
- Department of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden, The Netherlands,Paul van der Voort, Department of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, P.O. Box 9600, Leiden, 2333 ZA, The Netherlands.
| | - Danny van Delft
- Department of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden, The Netherlands
| | - Edward R Valstar
- Department of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden, The Netherlands,Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology Delft, The Netherlands
| | - Bart L Kaptein
- Department of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden, The Netherlands
| | - Marta Fiocco
- Department of Medical Statistics and Bioinformatics, Leiden University Medical Center, Leiden, The Netherlands,Mathematical Institute, Leiden University, Leiden, The Netherlands
| | - Rob GHH Nelissen
- Department of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
17
|
Anil U, Singh V, Schwarzkopf R. Diagnosis and Detection of Subtle Aseptic Loosening in Total Hip Arthroplasty. J Arthroplasty 2022; 37:1494-1500. [PMID: 35189292 DOI: 10.1016/j.arth.2022.02.060] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/10/2022] [Accepted: 02/14/2022] [Indexed: 02/02/2023] Open
Abstract
Aseptic loosening is a common cause of revision total hip arthroplasty (rTHA), and with the rising number of primary THAs, revisions for aseptic loosening represent a significant burden for arthroplasty surgeons. Aseptic loosening remains a diagnostic and management challenge. Loosening can occur as a result of inadequate initial fixation, mechanical loss of fixation over time, or a biological loss of fixation over time. However, in most cases, etiology is multifactorial, involving all 3 factors. The diagnosis of aseptic loosening involves a careful history, focused clinical exam, and thorough evaluation of imaging using several diagnostic modalities. The careful evaluation of serial radiographs remains the cornerstone of diagnosis with additional input from advanced imaging modalities such as FDG-PET, DEXA, MRI, and several others, each offering unique advantages and disadvantages. In certain patients, history and physical exam might be the only initial obvious signs of loosening, and thus, unexplained continuous pain augmented by imaging findings serves as an indication for revision surgery.
Collapse
Affiliation(s)
- Utkarsh Anil
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| | - Vivek Singh
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| |
Collapse
|
18
|
Mjöberg B. Hip prosthetic loosening and periprosthetic osteolysis: A commentary. World J Orthop 2022; 13:574-577. [PMID: 35949708 PMCID: PMC9244959 DOI: 10.5312/wjo.v13.i6.574] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 06/02/2022] [Accepted: 06/14/2022] [Indexed: 02/06/2023] Open
Abstract
Prosthetic loosening and periprosthetic osteolysis have been debated for decades, both in terms of the timing and nature of the triggering events. The hypothesis of wear-particle-induced loosening states that wear particles cause a foreign-body response leading to periprosthetic osteolysis and ultimately to late prosthetic loosening, i.e., that the osteolysis precedes the loosening. The theory of early loosening, on the other hand, postulates that the loosening is already initiated during or shortly after surgery, i.e., that the osteolysis is secondary to the loosening. This commentary focuses on the causal relationship between prosthetic loosening and periprosthetic osteolysis.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopedics, Lund University, Lund SE-221 00, Sweden
| |
Collapse
|
19
|
ANGELOMENOS V, MOHADDES M, ITAYEM R, SHAREGHI B. Precision of low-dose CT-based micromotion analysis technique for the assessment of early acetabular cup migration compared with gold standard RSA: a prospective study of 30 patients up to 1 year. Acta Orthop 2022; 93:459-465. [PMID: 35478261 PMCID: PMC9047498 DOI: 10.2340/17453674.2022.2528] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Computed tomography micromotion analysis (CTMA) can be used to determine implant micro-movements using low-dose CT scans. By using CTMA, a non-invasive measurement of joint implant movement is enabled. We evaluated the precision of CTMA in measuring early cup migration. Standard marker-based radiostereometric analysis (RSA) was used as reference. We hypothesised that CTMA can be used as an alternative to RSA in assessing implant micromotions. PATIENTS AND METHODS We included 30 patients undergoing total hip arthroplasty (THA). Acetabular cup migration at 1 year was measured with RSA and CTMA. To determine the precision of both methods, 20 double examinations (postoperatively) with repositioning of the patients were performed. The precision was calculated from zero by assuming that there was no motion of the prosthesis between the 2 examinations. RESULTS The precision of RSA ranged from 0.06 to 0.15 mm for translations and 0.21° to 0.63° for rotations. Corresponding values for CTMA were 0.06 to 0.13 mm and 0.23° to 0.35°. A good level of agreement was found between the methods regarding cup migration and rotation at 1 year. INTERPRETATION The precision of CTMA in measuring acetabular cup migration and rotation is comparable to marker-based RSA. CTMA could possibly thus be used as an alternative method to detect early implant migration.
Collapse
Affiliation(s)
- Vasileios ANGELOMENOS
- Department of Orthopedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg,Department of Orthopedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maziar MOHADDES
- Department of Orthopedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg,Department of Orthopedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Raed ITAYEM
- Department of Orthopedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg,Department of Orthopedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Bita SHAREGHI
- Department of Orthopedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg,Department of Orthopedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
20
|
Hsu AHS, Yen CH, Kuo FC, Wu CT, Huang TW, Cheng JT, Lee MS. Zoledronic Acid Ameliorates the Bone Turnover Activity and Periprosthetic Bone Preservation in Cementless Total Hip Arthroplasty. Pharmaceuticals (Basel) 2022; 15:ph15040420. [PMID: 35455417 PMCID: PMC9030653 DOI: 10.3390/ph15040420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 03/22/2022] [Accepted: 03/28/2022] [Indexed: 02/04/2023] Open
Abstract
The administration of zoledronic acid (ZA) to patients who received cementless total hip arthroplasty (THA) has been reported to reduce bone turnover markers (BTMs) and increase bone mineral density (BMD). The effects of two-dose ZA versus placebo on cementless THA patients were analyzed in this five-year extension study. Alkaline phosphatase (ALP), osteocalcin (OC), procollagen 1 intact N-terminal propeptide (P1NP), serum calcium, renal function, radiological findings, and functional outcomes were compared in 49 patients, and the periprosthetic BMD of seven Gruen zones were compared in 19 patients. All the patients had normal renal function and calcium levels at their final follow-up. The mean ALP level in the ZA group was significantly lower at the fifth year, mean OC levels were significantly lower at the second and fifth year, and mean P1NP levels were significantly lower from 6 weeks to 5 years as compared with the control group. Fifth-year BMD levels were not found to be different between the ZA and control groups. The BMD Change Ratios in the ZA group were significantly increased in Gruen zone 6 at 1, 2, and 5 years. Our study results suggest that short-term ZA treatment with a subsequent 4-year drug holiday may inhibit serum BTMs and provide periprosthetic bone preservation at five years without adverse events.
Collapse
Affiliation(s)
- Allen Herng Shouh Hsu
- Department of Orthopedic Surgery, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung City 833, Taiwan; (A.H.S.H.); (F.-C.K.); (C.-T.W.)
| | - Chun-Hsien Yen
- Ministry of Health and Welfare Cishan Hospital, Kaohsiung City 842, Taiwan;
| | - Feng-Chih Kuo
- Department of Orthopedic Surgery, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung City 833, Taiwan; (A.H.S.H.); (F.-C.K.); (C.-T.W.)
| | - Cheng-Ta Wu
- Department of Orthopedic Surgery, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung City 833, Taiwan; (A.H.S.H.); (F.-C.K.); (C.-T.W.)
| | - Tsan-Wen Huang
- Department of Orthopedic Surgery, Chia-Yi Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Chiayi City 621, Taiwan;
| | - Juei-Tang Cheng
- Department of Medical Research, Chi-Mei Hospital, Tainan City 710, Taiwan
- Correspondence: (J.-T.C.); (M.S.L.); Tel.: +886-6-2517864 (J.-T.C.); +886-7-7317123 (M.S.L.)
| | - Mel S. Lee
- Department of Orthopedic Surgery, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung City 833, Taiwan; (A.H.S.H.); (F.-C.K.); (C.-T.W.)
- Correspondence: (J.-T.C.); (M.S.L.); Tel.: +886-6-2517864 (J.-T.C.); +886-7-7317123 (M.S.L.)
| |
Collapse
|
21
|
RILBY K, MOHADDES M, NAUCLÉR E, KÄRRHOLM J. Similar outcome with a new anteverted or a straight standard stem: a randomized study of 72 total hip arthroplasties evaluated with clinical variables, radiostereometry, and DXA up to 2 years. Acta Orthop 2022; 93:59-67. [PMID: 34678118 PMCID: PMC8815675 DOI: 10.1080/17453674.2021.1993606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Indexed: 01/31/2023] Open
Abstract
Background and purpose - The anatomical uncemented stem, SP-CL (Static Physiologicus - CementLess), designed to facilitate insertion and to avoid stress concentration at solitary contact points, has been on the market since 2014 but is not well documented. We studied its clinical performance, migration, and associated bone remodeling in a randomized controlled trial, with the Corail stem as control. Patients and methods - 79 patients (80 hips) were primarily recruited and 71 patients (72 hips, 36 SP-CL, 36 Corail) attended the last follow-up at 2 years. The Oxford Hip Score (OHS) was the primary outcome. In addition, we assessed stem migration, changes in bone mineral density, and development of radiolucencies by RSA, DXA, and conventional radiography. Results - At 2 years Oxford Hip Score was similar between the SP-CL and Corail stem. At 2 years the SP-CL stems showed a median distal migration of 0.23 mm (-0.1 to 5.2) and the Corail stems of 0.11 mm (-0.4 to 4.4). The SP-CL stems showed slightly more loss of bone mineral density in Gruen region 7 (p = 0.003). Interpretation - We found no difference in clinical results between the SP-CL and the well-documented Corail stem. The same stem stability was reached between 1 and 2 years postoperatively for both stems. As a next step we think that the SP-CL stem should be studied in a multi-center setting, before being accepted for general use.
Collapse
Affiliation(s)
- Karin RILBY
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg
| | - Maziar MOHADDES
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg,Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Emma NAUCLÉR
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Johan KÄRRHOLM
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg,Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
22
|
Kok RY, Koster LA, Kaptein BL, Fiocco M, Keizer SB. A model-based radiostereometric analysis (RSA) randomized control trial evaluating the stability of the cementless Taperloc hip stem: the TapHip study. Acta Orthop 2022; 93:212-221. [PMID: 34984483 PMCID: PMC8815382 DOI: 10.2340/17453674.2021.1127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 12/02/2021] [Indexed: 01/31/2023] Open
Abstract
Background and purpose - The Taperloc Complete hip is the successor of the Taperloc hip, aiming to increase range of motion and optimizing femoral fit with intermediate stem sizes. We evaluated whether these design changes affect fixation, and this RSA study compares 2-year migration. Patients and methods - In this prospective, multi-arm study, 100 patients were randomized to cementless total hip arthroplasty (THA) with Taperloc Complete full profile (TCFP), Taperloc Complete reduced distal (TCRD), Taperloc full profile (TFP), or Taperloc reduced distal (TRD). Migration was measured with model-based RSA postoperatively, and after 3, 12, and 24 months. Results - Results based on mixed-model analysis on 2-year postoperative RSA data from 74 patients showed similar subsidence (mm) in the first 3 months (mean [95% CI] TCFP 0.44 [0.20-0.69], TCRD 0.91 [0.40-1.42], TFP 0.71 [0.22-1.19], TRD 1.25 [0.58-1.91]) and stabilization afterwards. The TCFP showed statistically significantly less retroversion (°) at 2-year postoperatively compared with TFP and TCRD (mean [95% CI] TCFP: -0.13 [-0.64 to 0.38], TCRD: 0.84 [0.35-1.33], TFP: 0.56 [0.12-1.00], TRD: 0.37 [-0.35 to 1.09]). Interpretation - As expected in successful cementless THA, RSA shows stabilization after initial subsidence. Based on these results the Taperloc Complete stem is expected to have similar long-term fixation to the Taperloc stems. The reduced distal groups have larger, but statistically non-significant, initial migration compared with the TCFP group, which could be due to implantation in Dorr B, C femur types. It may be important to consider the femur shape for choosing a full profile or reduced distal stem to minimize migration.
Collapse
Affiliation(s)
- Ruben Y Kok
- Focuskliniek Orthopedie, Haaglanden Medical Center, the Hague; Department of Orthopaedics, Leiden University Medical Center, Leiden.
| | - Lennard A Koster
- Department of Orthopaedics, Leiden University Medical Center, Leiden.
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden.
| | - Marta Fiocco
- Department of Medical Statistics and Bioinformatics, Leiden University Medical Center, Leiden; Mathematical Institute, Leiden University, Leiden, The Netherlands.
| | - Stefan B Keizer
- Focuskliniek Orthopedie, Haaglanden Medical Center, the Hague.
| |
Collapse
|
23
|
Sevaldsen K, Schnell Husby O, Lian ØB, Farran KM, Schnell Husby V. Is the French Paradox cementing philosophy superior to the standard cementing? A randomized controlled radiostereometric trial and comparative analysis. Bone Joint J 2022; 104-B:19-26. [PMID: 34969272 PMCID: PMC8779947 DOI: 10.1302/0301-620x.104b1.bjj-2021-0325.r2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Aims Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. Methods In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis. Results Results from mixed model analyses revealed a lower mean retroversion for line-to-line (0.72° (95% confidence interval (CI) 0.38° to 1.07°; p < 0.001), but no significant differences in subsidence between the techniques (-0.15 mm (95% CI -0.53 to 0.227; p = 0.429) at 24 months. Radiolucent lines measuring < 2 mm wide were found in three and five arthroplasties cemented by the standard and line-to-line method, respectively. Conclusion The cemented Corail stem with a force-closed design seems to settle earlier and better with the line-to-line cementing method, although for subsidence the difference was not significant. However, the lower rate of migration into retroversion may reduce the wear and cement deformation, contributing to good long-term fixation and implant survival. Cite this article: Bone Joint J 2022;104-B(1):19–26.
Collapse
Affiliation(s)
- Kirsti Sevaldsen
- Department of Orthopaedic Surgery, Kristiansund Hospital, Kristiansund, Norway.,Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Trondheim, Norway
| | - Otto Schnell Husby
- Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Trondheim, Norway.,Clinic of Orthopaedics, Rheumatology and Dermatology, Department of Orthopaedic Surgery, St. Olav's University Hospital, Trondheim, Norway
| | - Øystein Bjerkestrand Lian
- Department of Orthopaedic Surgery, Kristiansund Hospital, Kristiansund, Norway.,Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Trondheim, Norway
| | | | - Vigdis Schnell Husby
- Clinic of Orthopaedics, Rheumatology and Dermatology, Department of Orthopaedic Surgery, St. Olav's University Hospital, Trondheim, Norway.,Department of Health Science, Faculty of Medicine and Health Science, Norwegian University of Science and Technology, Ålesund, Norway
| |
Collapse
|
24
|
Peng Z, Jia Y, Li J, Wang G. Diagnostic Performance of Single-Photon Emission Computed Tomography/Computed Tomography in Aseptic Loosening: A Systematic Review and Meta-Analysis. J Arthroplasty 2021; 36:4003-4012.e3. [PMID: 34275709 DOI: 10.1016/j.arth.2021.06.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 06/04/2021] [Accepted: 06/17/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The aim of this study is to evaluate the diagnostic value and clinical applicability of single-photon emission computed tomography/computed tomography (SPECT/CT) in aseptic loosening (AL) of prostheses by meta-analysis. METHOD Literature on the diagnostic value of SPECT/CT in AL of prostheses was obtained by computer and manual review. The quality of the included studies was evaluated according to the Quality Assessment Diagnostic Accuracy Studies 2. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and other indicators were calculated, and a forest map and summary receiver operating characteristic were drawn to calculate the area under the curve. Meta-regression analysis was performed to identify the sources of heterogeneity and corresponding subgroup analysis was performed. A Fagan plot, likelihood ratio point plot, and Deek's funnel plot were drawn and analyzed. RESULTS A total of 15 studies were included. The meta-analysis results showed that the pooled sensitivity and specificity of SPECT/CT for the diagnosis of aseptic prosthetic loosening were 0.94, 95% confidence interval [CI] (0.90-0.96) and 0.89, 95% CI (0.78-0.95), respectively while the pooled positive likelihood ratio and pooled negative likelihood ratio were 8.65, 95% CI (4.18-17.90) and 0.07, 95% CI (0.04-0.11), respectively. The pooled diagnostic odds ratio was 130.36, 95% CI (45.18-376.19), and the area under the curve was 0.97, 95% CI (0.95-0.98). CONCLUSION As a diagnostic method for AL, SPECT/CT has high diagnostic sensitivity and specificity as well as high diagnostic efficiency. It has good clinical application value and should be a primary choice in the diagnosis of AL after joint replacement.
Collapse
Affiliation(s)
- Zhan Peng
- Department of Orthopaedic Surgery, Affiliated Baoan Hospital of Shenzhen, Southern Medical University, Shenzhen, People's Republic of China; Clinical Teaching Department, the Second School of Clinical Medicine, Southern Medical University, Shenzhen, People's Republic of China
| | - Yukun Jia
- Department of Orthopaedic Surgery, Affiliated Baoan Hospital of Shenzhen, Southern Medical University, Shenzhen, People's Republic of China; Clinical Teaching Department, the Second School of Clinical Medicine, Southern Medical University, Shenzhen, People's Republic of China
| | - Jin Li
- Department of Orthopaedic Surgery, Affiliated Baoan Hospital of Shenzhen, Southern Medical University, Shenzhen, People's Republic of China; Clinical Teaching Department, the Second School of Clinical Medicine, Southern Medical University, Shenzhen, People's Republic of China
| | - Guangye Wang
- Department of Orthopaedic Surgery, Affiliated Baoan Hospital of Shenzhen, Southern Medical University, Shenzhen, People's Republic of China; Clinical Teaching Department, the Second School of Clinical Medicine, Southern Medical University, Shenzhen, People's Republic of China
| |
Collapse
|
25
|
Two-year fixation and ten-year clinical outcomes of total knee arthroplasty inserted with normal-curing bone cement and slow-curing bone cement: A randomized controlled trial in 54 patients. Knee 2021; 33:110-124. [PMID: 34619515 DOI: 10.1016/j.knee.2021.08.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 05/12/2021] [Accepted: 08/25/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND The normal-curing Refobacin® Bone Cement R (RR) and slow-curing Refobacin® Plus Bone Cement (RP) were introduced after discontinuation of the historically most used bone cement, Refobacin®-Palacos® R, in 2005. The aim of this study was to compare total knee arthroplasty component fixation with the two bone cements. METHODS 54 patients with primary knee osteoarthritis were randomized to either RR (N = 27) or RP (N = 27) bone cement and followed for two years with radiostereometric analysis of tibial and femoral component migration and dual-energy x-ray absorptiometry measured periprosthetic bone mineral density (BMD). Further, patients were followed up at ten years with clinical outcome scores (OKS and KOOS). RESULTS At two-years follow-up, tibial total translation was 0.31 mm (95% CI: 0.19 - 0.42) for the RP group and 0.56 mm (95% CI: 0.45 - 0.67) (p < 0.01) for the RR group. There was continuous tibial component migration from one to two years follow-up (MTPM > 0.2 mm) in 13/27 patients from the RR and in 12/26 patients from the RP group. There was no difference between groups in BMD baseline values or changes during follow-up, as well as no correlation between change in BMD and tibial component migration. At ten-years follow-up, the improvement in the clinical outcome scores was similar between groups. There were no prosthesis related complications during the 10-year follow-up. CONCLUSION At two years, tibial total translation was lower in the RP compared with the RR cement group, but BMD changes were similar. At ten years, no components were revised and clinical outcome scores were similar between groups.
Collapse
|
26
|
Dyreborg K, Sørensen MS, Flivik G, Solgaard S, Petersen MM. Preoperative BMD does not influence femoral stem subsidence of uncemented THA when the femoral T-score is > -2.5. Acta Orthop 2021; 92:538-543. [PMID: 33977827 PMCID: PMC8522811 DOI: 10.1080/17453674.2021.1920163] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - It is believed that in uncemented primary total hip arthroplasty (THA) the anchorage of the stem is dependent on the level of bone mineral density (BMD) of the femoral bone. This is one of the reasons for the widely accepted agreement that a cemented solution should be selected for people with osteoporosis or age > 75 years. We evaluated whether preoperative BMD of the femur bone is related to femoral stem migration in uncemented THA.Patients and methods - We enrolled 62 patients (mean age 64 years (range 49-74), 34 males) scheduled for an uncemented THA. Before surgery we undertook DEXA scans of the proximal femur including calculation of the T- and Z-scores for the femoral neck. Evaluation of stem migration by radiostereometric analysis (RSA) was performed with 24 months of follow-up. In 56 patients both preoperative DEXA data and RSA data were available with 24 months of follow-up.Results - None of the patients had a T-score below -2.5. We found no statistically significant relationship between preoperative BMD and femoral stem subsidence after 3 or 24 months. When comparing the average femoral stem subsidence between 2 groups with T-score > -1 and T-score ≤ -1, respectively, we found no statistically significant difference after either 3 or 24 months when measured with RSA.Interpretation - In a cohort of people ≤ 75 years of age and with local femur T-score > -2.5 we found no relationship between preoperative BMD and postoperative femoral stem subsidence of a cementless THA.
Collapse
Affiliation(s)
- Karen Dyreborg
- Department of Orthopaedic Surgery, Rigshospitalet, København, Denmark
- Department of Hip and Knee Surgery, Herlev-Gentofte Hospital, Hellerup, Denmark
| | | | - Gunnar Flivik
- Department of Orthopaedics, Skåne University Hospital, Lund, Sweden
| | - Søren Solgaard
- Department of Hip and Knee Surgery, Herlev-Gentofte Hospital, Hellerup, Denmark
| | | |
Collapse
|
27
|
Aro HT. Bone quality makes a difference. Acta Orthop 2021; 92:503-504. [PMID: 34180754 PMCID: PMC8522809 DOI: 10.1080/17453674.2021.1941632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Affiliation(s)
- Hannu T. Aro
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland,Hannu T. Aro Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| |
Collapse
|
28
|
Mjöberg B. Hip prosthetic loosening: A very personal review. World J Orthop 2021; 12:629-639. [PMID: 34631447 PMCID: PMC8472441 DOI: 10.5312/wjo.v12.i9.629] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 05/03/2021] [Accepted: 08/03/2021] [Indexed: 02/06/2023] Open
Abstract
Hip prosthetic loosening is often difficult to detect at an early stage, and there has been uncertainty for a long time as to when the loosening occurs and thus to the basic causes. By comparing different diagnostic methods, we found that loosening is best defined as prosthetic migration and measured by radiostereometric analysis. Convincing evidence indicates that poor interlock, poor bone quality, and resorption of a necrotic bone bed may initiate loosening during or shortly after surgery; this forms the basis of the theory of early loosening. Biomechanical factors do affect the subsequent progression of loosening, which may increase subclinically during a long period of time. Eventually, the loosening may be detected on standard radiographs and may be interpreted as late loosening but should to be interpreted as late detection of loosening. The theory of early loosening explains the rapid early migration, the development of periprosthetic osteolysis and granulomas, the causality between wear and loosening, and largely the epidemiology of clinical failure of hip prostheses. Aspects discussed are definition of loosening, the pattern of early migration, the choice of migration threshold, the current understanding of loosening, a less exothermic bone cement, cemented taper-slip stems, a new exciting computed tomography-based technique for simpler implant migration studies, and research suggestions.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopedics, Lund University, Lund SE-221 00, Sweden
| |
Collapse
|
29
|
Relationship between the Surface Roughness of Material and Bone Cement: An Increased "Polished" Stem May Result in the Excessive Taper-Slip. MATERIALS 2021; 14:ma14133702. [PMID: 34279273 PMCID: PMC8269856 DOI: 10.3390/ma14133702] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 06/23/2021] [Accepted: 06/30/2021] [Indexed: 11/17/2022]
Abstract
Although some reports suggest that taper-slip cemented stems may be associated with a higher periprosthetic femoral fractures rate than composite-beam cemented stems, few studies have focused on the biomaterial effect of the polished material on the stem–cement interface. The purpose of this study was to investigate the relationship between surface roughness of materials and bone cement. Four types of metal discs—cobalt-chromium-molybdenum alloy (CoCr), stainless steel alloy 316 (SUS), and two titanium alloys (Ti-6Al-4V and Ti-15Mo-5Zr-3Al)—were prepared. Five discs of each material were produced with varying degrees of surface roughness. In order to evaluate surface wettability, the contact angle was measured using the sessile drop method. A pin was made using two bone cements and the frictional coefficient was assessed with a pin-on-disc test. The contact angle of each metal increased with decreasing surface roughness and the surface wettability of metal decreased with higher degrees of polishing. With a surface roughness of Ra = 0.06 μm and moderate viscosity bone cement, the frictional coefficient was significantly lower in CoCr than in SUS (p = 0.0073). In CoCr, the low adhesion effect with low frictional coefficient may result in excessive taper-slip, especially with the use of moderate viscosity bone cement.
Collapse
|
30
|
Initial femoral stem position in cementless bipolar hemiarthroplasty for femoral neck fracture in elderly patients is associated with early implant subsidence: A radiographic analysis. Injury 2021; 52:1801-1806. [PMID: 34039470 DOI: 10.1016/j.injury.2021.05.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Revised: 04/14/2021] [Accepted: 05/06/2021] [Indexed: 02/08/2023]
Abstract
BACKGROUND Bipolar hemiarthroplasty is a well-established treatment for displaced femoral neck fracture in elderly patients. Implant subsidence is a potential complication with cementless femoral stems, and smaller canal fill ratio has been reported as a radiographic risk factor. We aimed to determine the risk factors for subsidence, particularly the initial implant position relative to the resected medial calcar of proximal femur. METHODS We retrospectively reviewed all cementless bipolar hemiarthroplasties performed using a single proximally hydroxyapatite-coated femoral stem in patients with a minimum radiographic follow-up of 12 weeks between January 2017 and December 2018. The amount of subsidence (significant subsidence defined as ≥ 5 mm), canal fill ratio, and implant position relative to the point of resected medial calcar (position A: medial and superior to calcar; position B: lateral and superior to calcar; position C: lateral and inferior to calcar) were measured and analyzed. RESULTS One-hundred eighty patients were identified (mean age: 80.9 years). Significant subsidence was observed in 52 patients (28.9%). On multivariate analysis, older age, lower canal fill ratio, implant position B, C, and less medial overhang of stem were independent risk factors for early implant subsidence. The risk ratio of position B and C to position A was 5.13 (95% confidence interval, 2.23-11.80). CONCLUSION In our analysis, older age and lower canal fill ratio were associated with increased risk of subsidence, whereas implant with position A and more medial overhang were less prone to subsidence with the tapered proximally hydroxyapatite-coated implant.
Collapse
|
31
|
de Waard S, Sierevelt IN, Jonker R, Hoornenborg D, van der Vis HM, Kerkhoffs GMMJ, Haverkamp D. The migration pattern and initial stability of the Optimys short stem in total hip arthroplasty: a prospective 2-year follow-up study of 33 patients with RSA. Hip Int 2021; 31:507-515. [PMID: 31971010 DOI: 10.1177/1120700020901844] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND PURPOSE The consensus that bone stock preservation and optimal restoration of offset and leg length is important in total hip arthroplasty is now widespread, especially for young and active patients. Short stems seem promising in this aspect, though implant stability is still of concern. This study looked at the migration pattern of the Optimys short stem through RSA analysis. PATIENTS AND METHODS 40 patients were included. RSA images were made directly postoperatively (within 5 days), at 6 weeks and at 3, 6, 12 and 24 months. Double examinations were made for precision measurement. HOOS and pain scores were obtained preoperatively and at 2 years. 4 patients were excluded due to protocol violation and 1 patient was excluded for RSA analysis with a CN number >110. 2 patients were lost to follow-up after 3 and 6 months (n = 1 lost, n = 1 deep infection, respectively). RESULTS Mean age was 60 years with a mean BMI of 27. RSA analysis of 34 patients showed a significant initial median proximodistal translation (subsidence) of 0.21 mm (IQR 0.64-0.06) and anteversion-retroversion rotation of 0.59° (IQR 0.01-1.34) at 6 weeks, after which the stem stabilises and showed no further significant movement. Median migration in other directions was small. 4 patients had an initial subsidence of >2 mm, all showed secondary stabilisation. HOOS outcomes were satisfactory, with the domain symptoms and pain showing a median score of 95/100 at 2 years. CONCLUSIONS After initial migration the Optimys achieves secondary stabilisation, suggesting low risk on long-term aseptic loosening. CLINICAL TRIALS REGISTRATION NL47055.048.13.
Collapse
Affiliation(s)
- Sheryl de Waard
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands.,Academic Medical Centre (AMC), Amsterdam, Netherlands
| | - Inger N Sierevelt
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Renee Jonker
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Daniel Hoornenborg
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Harm M van der Vis
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | | | - Daniël Haverkamp
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| |
Collapse
|
32
|
Weber E, Flivik C, Sundberg M, Flivik G. Migration pattern of a short uncemented stem with or without collar: a randomised RSA-study with 2 years follow-up. Hip Int 2021; 31:500-506. [PMID: 31793347 DOI: 10.1177/1120700019888471] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND There is an increasing interest in shorter, proximally loading, uncemented femoral stems. The aim of this study was to evaluate a new short stem type, its design based on a well-proven precursor, but with several new design features to facilitate easier insertion and possible preservation of proximal bone stock. It is available with or without a collar. METHODS The study includes 50 patients with primary osteoarthritis, mean age 59 (range 36-75) years, randomised to receive either the collar-fitted or the collarless stem. The patients underwent repeated radiostereometry (RSA) examinations (0, 0.5, 3, 12, 24 months), conventional radiography and filled out both hip-specific (HOOS) and general health (EQ-5D) questionnaires. RESULTS There was no statistically significant difference between the collared and collarless stems regarding migration and clinical outcome. Both stem types exhibit a similar pattern of initial subsidence (collared 0.63 mm vs. collarless 0.75 mm [p = 0.50]) and retroversion (collared 0.71° vs. collarless 0.97° [p = 0.36]) up to 3 months followed by stabilisation, in similarity with its precursors, suggesting good osseointegration. No stem has been revised or considered loose. CONCLUSIONS The new design features, including shortening the stem, do not compromise migration pattern or osseointegration, regardless collar or not.
Collapse
Affiliation(s)
- Erik Weber
- Department of Orthopaedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| | - Carl Flivik
- Department of Orthopaedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| | - Martin Sundberg
- Department of Orthopaedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| | - Gunnar Flivik
- Department of Orthopaedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
33
|
Baryeh K, Mendis J, Sochart DH. Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review. EFORT Open Rev 2021; 6:331-342. [PMID: 34150327 PMCID: PMC8183154 DOI: 10.1302/2058-5241.6.200086] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The literature was reviewed to establish the levels of stem subsidence for both double and triple-tapered implants in order to determine whether there were any differences in subsidence levels with regard to the methods of measurement, the magnitude and rate of subsidence and clinical outcomes. All studies reporting subsidence of polished taper-slip stems were identified. Patient demographics, implant design, radiological findings, details of surgical technique, methods of measurement and levels of subsidence were collected to investigate which factors were related to increased subsidence. Following application of inclusion and exclusion criteria, 28 papers of relevance were identified. The studies initially recruited 3090 hips with 2099 being available for radiological analysis at final follow-up. Patient age averaged 68 years (42–70), 60.4% were female and the average body mass index (BMI) was 27.4 kg/m2 (24.1–29.2). Mean subsidence at one, two, five and 10 years was 0.97 mm, 1.07 mm, 1.47 mm and 1.61 mm respectively. Although double-tapered stems subsided more than triple-tapered stems at all time points this was not statistically significant (p > 0.05), nor was the method of measurement used (p > 0.05). We report the levels of subsidence at which clinical outcomes and survivorship remain excellent, but based on the literature it was not possible to determine a threshold of subsidence beyond which failure was more likely. There were relatively few studies of triple-tapered stems, but given that there were no statistically significant differences, the levels presented in this review can be applied to both double and triple-tapered designs.
Cite this article: EFORT Open Rev 2021;6:331-342. DOI: 10.1302/2058-5241.6.200086
Collapse
Affiliation(s)
- Kwaku Baryeh
- The Academic Surgical Unit, South West London Elective Orthopaedic Centre, UK
| | | | - David H Sochart
- The Academic Surgical Unit, South West London Elective Orthopaedic Centre, UK
| |
Collapse
|
34
|
Emara AK, Ng M, Krebs VE, Bloomfield M, Molloy RM, Piuzzi NS. Femoral Stem Cementation in Hip Arthroplasty: The Know-How of a "Lost" Art. Curr Rev Musculoskelet Med 2021; 14:47-59. [PMID: 33453016 PMCID: PMC7930165 DOI: 10.1007/s12178-020-09681-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/17/2020] [Indexed: 01/16/2023]
Abstract
PURPOSE OF REVIEW To describe the (1) indications, (2) preoperative precautions, and (3) stepwise technical details of modern femoral stem cemented fixation. RECENT FINDINGS Femoral stem cementation provides excellent implant longevity with a low periprosthetic fracture rate among patients with compromised bone quality or aberrant anatomy. Unfamiliarity with the details of modern cementation techniques among trainees who may lack frequent exposure to cementing femoral stems may preclude them from offering this viable option to suitable patients in later stages of their careers. As such, maximizing benefit from cemented femoral stem fixation among suitable candidates is contingent upon the meticulous use of modern cementation techniques. In addition to proper patient selection, modern cementation techniques emphasize the use of (1) pulsatile lavage of the femoral canal, (2) utilization of epinephrine-soaked swabs, (3) vacuum cement mixing, (4) retrograde cement introduction, (5) cement pressurization, and (6) the use of stem centralizers. Furthermore, identifying and optimizing the preoperative status of at-risk patients with pre-existing cardiopulmonary compromise, in addition to intraoperative vigilance, are essential for mitigating the risk of developing bone cement implantation syndrome. Further research is required to assess the utility of cemented femoral stem fixation among younger patients.
Collapse
Affiliation(s)
- Ahmed K Emara
- Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Mitchell Ng
- Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Viktor E Krebs
- Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | | | - Robert M Molloy
- Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Nicolas S Piuzzi
- Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH, USA.
| |
Collapse
|
35
|
Coffey SP, Sorial RM, Sharma R, Field JR. Two-year migration characteristics of a novel cementless femoral stem: a radiostereometric analysis and clinical outcomes study. ANZ J Surg 2021; 91:398-403. [PMID: 33522681 DOI: 10.1111/ans.16616] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 01/05/2021] [Accepted: 01/06/2021] [Indexed: 12/19/2022]
Abstract
BACKGROUND Radiostereometric analysis (RSA) is an established high precision tool enabling us to detect early implant migration in total hip arthroplasty. The aim of this study is to present the RSA and clinical results of a new cementless hip stem and to compare those with established benchmarks. METHODS A total of 45 patients (46 hips) undergoing total hip arthroplasty were available for full radiographic and clinical assessment at 2 years post-operatively. Mean patient age was 69 (range 43-85) years and mean body mass index was 29 (range 21-38) kg/m2 . RSA was undertaken at day 1, 6 weeks, 6 months and 1 and 2 years post-operatively. Oxford hip score and EQ-5D-5L scores were recorded preoperatively and at the same other time points. Results were compared to published data of established implants. RESULTS At 2 years, mean subsidence and retroversion were 0.61 mm (standard deviation 0.7 mm, range -0.19 to 3.06 mm) and 0.44° (standard deviation 0.81°, range 0.98 to 3.29°), respectively. Stem migration occurred primarily in the first 6 weeks with no detectable subsidence or rotation at 6 months or 2 years. Mean Oxford hip score and EQ-5D-5L improved from 18.6 to 44.7, and 69 to 86, respectively. There was one cup-only revision and no revisions for stem loosening. CONCLUSION RSA serves as an accurate measure of femoral stem stability early in the post-operative period. Our data confirm that stability occurs as early as 6 weeks and is sustained at 2 years. The Paragon stem demonstrates stability parameters at 2 years that exceed other established benchmark implants.
Collapse
Affiliation(s)
- Simon P Coffey
- Department of Orthopaedics, Nepean Hospital, Penrith, New South Wales, Australia
| | - Rami M Sorial
- Department of Orthopaedics, Nepean Hospital, Penrith, New South Wales, Australia
| | - Rahul Sharma
- Department of Orthopaedics, Nepean Private Hospital, Penrith, New South Wales, Australia
| | - John R Field
- Department of Orthopaedic Surgery, Nepean Private Hospital, Penrith, New South Wales, Australia
| |
Collapse
|
36
|
Nazari-Farsani S, Vuopio M, Löyttyniemi E, Aro HT. Contributing factors to the initial femoral stem migration in cementless total hip arthroplasty of postmenopausal women. J Biomech 2021; 117:110262. [PMID: 33508723 DOI: 10.1016/j.jbiomech.2021.110262] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 01/01/2021] [Accepted: 01/10/2021] [Indexed: 02/06/2023]
Abstract
In cementless total hip arthroplasty (THA), femoral stems rely on the initial press-fit fixation against cortical bone to achieve osseointegration. Decreased bone mineral density (BMD) in postmenopausal women poses natural difficulties in achieving axial and rotational femoral stem stability. The present study examined contributing demographic, surgery-related and postoperative factors in determining the magnitude of early stem migration prior to osseointegration. A prospective cohort of 65 postmenopausal women with hip osteoarthritis (Dorr type A or B femur anatomy) underwent THA with implantation of an uncemented parallel-sided femoral component. Postoperative femoral stem translation and rotation were measured using model-based radiostereometric analysis. Based on analysis of covariance, which controlled for outliers and randomized antiresorptive treatment with denosumab or placebo, none of the analyzed demographics (including BMI) and surgery-related variables (including the stem-to-canal fil ratio) was associated with stem subsidence. Stem subsidence (mean 1.8 mm, 95% CI 1.2 to 2.4) occurred even in women with normal hip BMD. Total hip BMD and postoperative walking activity (measured three months after surgery) were significantly associated with stem rotation, and height acted as a confounding factor. The effect of walking activity on stem rotation was significant at 5 months (p = 0.0083) and at 11 months (p = 0.0117). This observation confirms the previous results of instrumented hip prostheses on torsional moments affecting stems during daily activities. High-resolution imaging modalities of local bone quality are needed to explore reasons for RSA-measurable stem subsidence even in women with normal hip BMD.
Collapse
Affiliation(s)
- Sanaz Nazari-Farsani
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Mia Vuopio
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Eliisa Löyttyniemi
- Unit of Biostatistics, Department of Clinical Medicine, University of Turku, Turku, Finland
| | - Hannu T Aro
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland.
| |
Collapse
|
37
|
Van Der Voort P, D Klein Nulent ML, Valstar ER, Kaptein BL, Fiocco M, G H H Nelissen R. Long-term migration of a cementless stem with different bioactive coatings. Data from a "prime" RSA study: lessons learned. Acta Orthop 2020; 91:660-668. [PMID: 33143507 PMCID: PMC8023916 DOI: 10.1080/17453674.2020.1840021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Little is known about the long-term migration pattern of cementless stems in total hip arthroplasty (THA). Furthermore, the role of bioactive coatings in fixation, and thus migration, remains uncertain. Hydroxyapatite (HA) is the most commonly used bioactive coating. However, delamination of the coating might induce loosening. Alternatively, fluorapatite (FA) has proved to be more thermostable than HA, thereby potentially increasing longevity. We assessed the long-term migration of cementless stems with different coatings using radiostereometric analysis (RSA), thereby establishing a reference for acceptable migration. Patients and methods - 61 THAs in 53 patients were randomized to receive either a HA, FA, or uncoated Mallory-Head Porous stem during the years 1992 to 1994. Primary outcome was stem migration measured using RSA and secondary outcome was the Harris Hip Score (HHS). Evaluation took place preoperatively and postoperatively on the second day, at 6, 12, 25 and 52 weeks, and annually thereafter. At the 25-year follow-up, 12 patients (17 THAs) had died and 1 patient (1 THA) was lost to follow-up. Due to the high number of missing second-day postoperative RSA radiographs, the 1-year postoperative RSA radiograph was used as baseline for the comparative analyses. Results - Mean follow-up was 17 years (SD 6.6). All stems showed initial rapid migration with median subsidence of 0.2 mm (-0.1 to 0.6) and median retroversion of 0.9° (-3.2 to 2) at 12 months, followed by stable migration reaching a plateau phase. No stem was revised, albeit 1 stem showed continuous subsidence up to 1.5 mm. Comparing the different coatings, we could not find a statistically significant difference in overall 25-year migration (p-values > 0.05). Median subsidence at 15-year follow-up was for HA -0.1 mm (-0.4 to 0.2), for FA 0 mm (-0.1 to 0.2), and for uncoated stems 0.2 mm (-0.1 to 0.5). Median internal rotation at 15-year follow-up was for HA not available, for FA 1.1° (-0.5 to 2.6), and for uncoated stems 0° (-0.5 to 0.4). HHS were also comparable (p-values > 0.05), with at 15-year follow-up for HA 85 points (41-99), for FA 76 points (61-90), and for uncoated stems 79 points (74-90). Interpretation - The long-term migration pattern of cementless stems using different bioactive coatings has not previously been described. No beneficial effect, or side effect at long-term follow-up of bioactive coatings, was found. The provided migration data can be used in future research to establish thresholds for acceptable migration patterns cementless stem designs.
Collapse
Affiliation(s)
- Paul Van Der Voort
- Department of Orthopaedics, Leiden University Medical Center, Leiden; ,Correspondence:
| | | | - Edward R Valstar
- Department of Orthopaedics, Leiden University Medical Center, Leiden; ,Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, University of Technology Delft, Delft;
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden;
| | - Marta Fiocco
- Department of Medical Statistics and Bioinformatics, Leiden University Medical Center, Leiden; ,Mathematical Institute, Leiden University, Leiden, The Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden; ,Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, University of Technology Delft, Delft;
| |
Collapse
|
38
|
Perelgut ME, Polus JS, Lanting BA, Teeter MG. The effect of femoral stem collar on implant migration and clinical outcomes following direct anterior approach total hip arthroplasty. Bone Joint J 2020; 102-B:1654-1661. [PMID: 33249909 DOI: 10.1302/0301-620x.102b12.bjj-2019-1428.r1] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
AIMS The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach. METHODS Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively. RESULTS Comparing the RSA between the day of surgery baseline exam to two weeks postoperatively, subsidence was significantly lower (mean difference 2.23 mm (SD 0.71), p = 0.023) with collared stems, though these patients had a greater CFR (p = 0.048). There was no difference (p = 0.426) in subsidence between stems from a two-week baseline through to one year postoperatively. There were no clinically relevant differences in PROMs; and there was no difference in the change in activity (p = 0.078) or the change in functional capacity (p = 0.664) between the collared stem group and the collarless stem group at any timepoint. CONCLUSION Presence of a collar on the femoral stem resulted in reduced subsidence during the first two postoperative weeks following primary THA using the DA approach. However, the clinical implications are unclear, and larger studies examining patient activity and outcomes are required. Cite this article: Bone Joint J 2020;102-B(12):1654-1661.
Collapse
Affiliation(s)
- Maxwell E Perelgut
- School of Biomedical Engineering, Western University, London, Ontario, Canada.,Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada
| | - Jennifer S Polus
- School of Biomedical Engineering, Western University, London, Ontario, Canada.,Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada
| | - Brent A Lanting
- Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
| | - Matthew G Teeter
- School of Biomedical Engineering, Western University, London, Ontario, Canada.,Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.,Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada.,Surgical Innovation Program, Lawson Health Research Institute, London, Ontario, Canada
| |
Collapse
|
39
|
[Early assessment of the risk of later implantloosening using Roentgen Sterophotogrammetric Analysis (RSA)]. DER ORTHOPADE 2020; 49:1042-1048. [PMID: 33108489 DOI: 10.1007/s00132-020-04027-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND Aseptic implant loosening is the most common cause of implant revisions in total hip and total knee arthroplasty. Roentgen Stereophotogrammetric Analysis (RSA) represents the current gold standard for the in-vivo assessment of implant fixation. PRESENT SITUATION Long-term clinical trials have shown that continuous implant migration within the first two postoperative years correlates strongly with a later aseptic loosening. Thus, the implant migration measured with RSA can be regarded as a reliable surrogate marker for later implant loosening. Over the past 40 years, RSA has been continuously further developed, and the model-based RSA approach has reduced the effort involved since markers attached to implant are no longer needed. PERSPECTIVES The RSA method is gaining importance in the certification process of new orthopaedic implants-for example, the Dutch Orthopedic Society has recommended phased-introduction and RSA studies for new hip implants. Furthermore, in the context of the new EU Medical Device Regulation (MDR), which took effect in May 2017, RSA gained relevance for investigating clinically unproven implants. Critics who associate MDR with hindering innovation can be countered in that the RSA method provides a predictive assessment of implant fixation after only two years of follow-up, which is significantly shorter than standard long-term clinical trials.
Collapse
|
40
|
Wilkinson JM. The use of bisphosphonates to meet orthopaedic challenges. Bone 2020; 137:115443. [PMID: 32445893 DOI: 10.1016/j.bone.2020.115443] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 05/14/2020] [Accepted: 05/19/2020] [Indexed: 11/17/2022]
Abstract
The anti-resorptive properties of bisphosphonates have been explored to manage several conditions that traditionally have required a surgical solution. In osteonecrosis, their use is predicated on the principle that bone collapse occurs during the revascularisation phase of the disease. If the associated resorptive activity were modulated, the resultant preserved joint architecture may improve clinical outcome and reduce the need for joint replacement. Pre-clinical and small-scale clinical studies have given non-conclusive support for this principle. Adequately powered clinical trials with relevant long-term endpoints are still required to firmly clarify the clinical efficacy of this treatment. Several clinical studies have shown that bisphosphonates can reduce periprosthetic bone loss and, in some situations, enhance implant fixation in the early period after joint replacement. This may be advantageous in settings where osseointegration is problematic. However, the ultimate goals of their use in joint replacement has been to reduce the incidence of late periprosthetic inflammatory osteolysis, the main cause of prosthesis failure. Population-based observational studies have associated bisphosphonate use with a lower incidence of revision surgery, supported by pre-clinical data. However, clinical trials have, to date, failed to demonstrate any efficacy for the human disease. The timing of bisphosphonate administration for secondary prevention after acute osteoporotic fracture has been subject to extensive investigation, with pre-clinical studies showing increased callus formation but decreased remodelling and no effect on the restoration of mechanical integrity of bone. Meta-analysis of clinical trial data indicates that early administration of bisphosphonate after acute fracture does not adversely affect fracture union, pain or functional outcomes. Finally, bisphosphonates have also been explored as a treatment for complex regional pain syndrome type-I. A recent meta-analysis has shown a beneficial effect on visual analogue scale pain scores, but an increase in mild adverse events.
Collapse
Affiliation(s)
- J Mark Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, United Kingdom.
| |
Collapse
|
41
|
Aro HT, Nazari-Farsani S. RSA of the Symax hip stem. Acta Orthop 2020; 91:497-499. [PMID: 32396420 PMCID: PMC8023896 DOI: 10.1080/17453674.2020.1763042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Affiliation(s)
- Hannu T Aro
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands,E-mail:
| | - Sanaz Nazari-Farsani
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
42
|
The Migration Pattern of a Cementless Hydroxyapatite-Coated Titanium Stem under Immediate Full Weight-Bearing-A Randomized Controlled Trial Using Model-Based RSA. J Clin Med 2020; 9:jcm9072077. [PMID: 32630629 PMCID: PMC7408977 DOI: 10.3390/jcm9072077] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 06/21/2020] [Accepted: 06/29/2020] [Indexed: 11/17/2022] Open
Abstract
(1) Background: High primary stability is important for the long-term survival of cementless femoral stems in total hip arthroplasty (THA). The objective of this study was to investigate the migration pattern of a hydroxyapatite-coated cementless hip stem developed for minimally invasive surgery using model-based radiostereometric analysis (RSA). (2) Methods: In this randomized controlled trial, 44 patients with an indication for cementless primary THA were randomly allocated to receive either the SL-PLUS MIA stem, developed for minimally invasive surgery, or the SL-PLUS stem (Smith & Nephew Orthopaedics, Baar, Switzerland) which served as a control group. Unlimited weight-bearing was permitted postoperatively in both groups. Model-based RSA was performed after six weeks and after 3, 6, 12 and 24 months postoperatively. (3) Results: Mean total stem subsidence at two-year follow-up was 0.40 mm (SD 0.66 mm) in the SL-PLUS group and 1.08 mm (SD 0.93 mm) in the SL-PLUS MIA group (p = 0.030). Stem subsidence occurred during the first six weeks after surgery, indicating initial settling of the stem under full weight-bearing. Both stem designs showed good osseointegration and high secondary stability with no further migration after initial settling. (4) Conclusions: Settling of a cementless straight femoral stem occurs during the first six weeks after surgery under full weight-bearing. Although initial stem migration was higher in the SL-PLUS MIA group, it had no influence on secondary stability. All implants showed good osseointegration and high secondary stability with no signs of implant loosening during this two-year follow-up period.
Collapse
|
43
|
Nazari-Farsani S, Vuopio ME, Aro HT. Bone Mineral Density and Cortical-Bone Thickness of the Distal Radius Predict Femoral Stem Subsidence in Postmenopausal Women. J Arthroplasty 2020; 35:1877-1884.e1. [PMID: 32205004 DOI: 10.1016/j.arth.2020.02.062] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Revised: 02/21/2020] [Accepted: 02/26/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The distal radius is an optional site for evaluation of bone quality in postmenopausal women before cementless total hip arthroplasty. We hypothesized that dual-energy X-ray absorptiometry (DXA) and pulse-echo ultrasonometry of the distal radius may help discriminate subjects at high risk of femoral stem subsidence. METHODS A prospective cohort of postmenopausal women with primary hip osteoarthritis underwent total hip arthroplasty with implantation of a parallel-sided femoral stem. Postoperative stem migration was measured using radiostereometric analysis. Preoperatively, subjects had multisite DXA measurement of bone mineral density (BMD) and pulse-echo ultrasonometry of the cortical-bone thickness. The diagnostic abilities of these methods to discriminate <2 mm and ≥2 mm femoral stem subsidence were tested. RESULTS The accuracy of the distal radius BMD and cortical-bone thickness of the distal radius were moderate (area under the curve, 0.737 and 0.726, respectively) in discriminating between <2 mm and ≥2 mm stem subsidence. Women with low cortical-bone thickness of the radius were more likely (odds ratio = 6.7; P = .002) to develop stem subsidence ≥2 mm. These subjects had lower total hip BMD (P = .007) and reduced thickness of the medial cortex of the proximal femur (P = .048) with lower middle (P < .001) and distal (P = .004) stem-to-canal fill ratios. CONCLUSION Femoral stem stability and resistance to subsidence are sensitive to adequate bone stock and unaltered anatomy. DXA and pulse-echo ultrasonometry of the distal radius may help discriminate postmenopausal women at high risk of stem subsidence.
Collapse
Affiliation(s)
- Sanaz Nazari-Farsani
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Mia E Vuopio
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Hannu T Aro
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| |
Collapse
|
44
|
Abstract
AIMS Short, bone-conserving femoral components are increasingly used in total hip arthroplasty (THA). They are expected to allow tissue-conserving implantation and to render future revision surgery more straightforward but the long-term data on such components is limited. One such component is the global tissue-sparing (GTS) stem. Following the model for stepwise introduction of new orthopaedic implants, we evaluated early implant fixation and clinical outcome of this novel short-stem THA and compared it to that of a component with established good long-term clinical outcome. METHODS In total, 50 consecutive patients ≤ 70 years old with end-stage symptomatic osteo-arthritis were randomized to receive THA with the GTS stem or the conventional Taperloc stem using the anterior supine intermuscular approach by two experienced hip surgeons in two hospitals in the Netherlands. Primary outcome was implant migration. Patients were followed using routine clinical examination, patient reported outcome using Harris Hip Score (HHS), Hip Disability And Osteoarthritis Outcome Score (HOOS), EuroQol five-dimension questionnaire (EQ5D), and Roentgen Stereophotogrammetric Analysis (RSA) at three, six, 12, and 24 months. This study evaluated the two-year follow-up results. RESULTS In addition to the initial migration pattern of distal migration (subsidence, Y-translation) and retroversion (Y-rotation) also exhibited by the Taperloc stem, the GTS stem showed an initial migration pattern of varization (X-translation combined with Z-rotation) and posterior translation (Z-translation). However, all components stabilized aside from one Taperloc stem which became loose secondary to malposition and was later revised. Clinical outcomes and complications were not statistically significantly different with the numbers available. CONCLUSION A substantially different and more extensive initial migration pattern was seen for the GTS stem compared to the Taperloc stem. Although implant stabilization was achieved, excellent long-term survival similar to that of the Taperloc stem should not be inferred. Especially in the absence of clinically proven relevant improvement, widespread usage should be postponed until long-term safety has been established. Cite this article: Bone Joint J 2020;102-B(6):699-708.
Collapse
Affiliation(s)
- Marc J Nieuwenhuijse
- Department of Orthopaedic Surgery, Haaglanden Medical Center, The Hague, the Netherlands
| | - Stephan B W Vehmeijer
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, the Netherlands
| | - Nina M C Mathijsen
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, the Netherlands
| | - Stefan B Keizer
- Department of Orthopaedic Surgery, Haaglanden Medical Center, The Hague, the Netherlands
| |
Collapse
|
45
|
Lindgren L, Jørgensen PB, Mørup RMS, Jensen M, Rømer L, Kaptein B, Stilling M. Similar patient positioning: A key factor in follow-up studies when using model-based radiostereometric analysis of the hip. Radiography (Lond) 2020; 26:e45-e51. [PMID: 32052775 DOI: 10.1016/j.radi.2019.10.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 08/30/2019] [Accepted: 10/22/2019] [Indexed: 01/28/2023]
Abstract
INTRODUCTION Despite protocols, patients are not positioned exactly alike at radiostereometric (RSA) follow-up examinations, and it is unknown how much variation is tolerable. We report precision for optimal and extreme position differences from a phantom hip-study, and clinical precision of hip-RSA. METHODS A femoral stem with 3 bead-towers was fixed in a saw bone with bone-markers (phantom), and series of RSA examinations within optimal (5 × 5 cm and 5°) and extreme (20 × 30 cm and 30°) phantom positions were obtained. Double-examination RSA of 12 patients with the same femoral stem type were analyzed. Both model-based (CAD) and marker-based (MM) analysis was used. Precision was reported as standard deviation of differences. RESULTS Precision for translations in the optimal and extreme phantom position were below 0.06 mm and 0.02 mm for MM analysis, and below 0.05 mm and 0.18 mm for CAD analysis, respectively. Precision for rotations in the optimal and extreme phantom rotation were below 0.18° and 0.26° for MM analysis, and below 0.34° and 0.52° for CAD analysis, respectively. Clinical precision was 0.29 mm and 0.44° for MM analysis, and 0.40 mm and 1.59° for CAD analysis. CONCLUSION Extreme differences in patient position during RSA examination negatively affects precision, and CAD model-analysis was more sensitive than MM analysis. Longitudinal translation and rotation about the long stem-axis are the effect parameters which are most affected by position and rotation changes, and also the best indicators of implant loosening. IMPLICATIONS FOR PRACTICE Based on our research, we recommend that similar patient positioning between follow-up RSA examinations is debated and prioritized.
Collapse
Affiliation(s)
- L Lindgren
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - P B Jørgensen
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - R M S Mørup
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - M Jensen
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - L Rømer
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - B Kaptein
- Biomechanics and Imaging Group (BIG), Leiden University Medical Center, P.O. Box 9600, 2300 RC, Leiden, the Netherlands.
| | - M Stilling
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| |
Collapse
|
46
|
Abstract
Prosthetic loosening has been debated for decades, both in terms of the timing and nature of the triggering events. Multiple radiostereometric studies of hip prostheses have now shown that early migration poses a risk of future clinical failure, but is this enough to explain late clinical loosening?To answer this question, the progression of loosening from initiation to radiographic detection is described; and the need for explanations other than early prosthetic loosening is analysed, such as stress-shielding, particle disease, and metal sensitivity.Much evidence indicates that prosthetic loosening has already been initiated during or shortly after the surgery, and that the subsequent progression of loosening is affected by biomechanical factors, fluid pressure fluctuations and inflammatory responses to necrotic cells and cell fragments, i.e. the concept of late loosening appears to be a misinterpretation of late-detected loosening.Clinical implications: atraumatic surgery and initial prosthetic stability are crucial in ensuring low risk of prosthetic loosening. Cite this article: EFORT Open Rev 2020;5:113-117. DOI: 10.1302/2058-5241.5.190014.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopaedics, Lund University, Lund, Sweden
- Bengt Mjöberg, Västra Vallgatan 29, SE-27135 Ystad, Sweden.
| |
Collapse
|
47
|
Kruijntjens DSMG, Koster L, Kaptein BL, Jutten LMC, Arts JJ, Ten Broeke RHM. Early stabilization of the uncemented Symax hip stem in a 2-year RSA study. Acta Orthop 2020; 91:159-164. [PMID: 31928120 PMCID: PMC7144261 DOI: 10.1080/17453674.2019.1709956] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The uncemented Symax hip stem has shown early proximal ingrowth as result of the BONIT-hydroxyapatite (HA) coating and the distal DOTIZE surface treatment. We evaluated 2-year postoperative radiostereometric analysis (RSA) migration of the Symax hip stem in THA patients. We also investigated the correlation between migration at 4 weeks and clinical outcomes after 2 years.Patients and methods - Patients in a 2-year clinical follow-up single-centre RSA randomized controlled trial were randomized to 2 different cup designs. All 45 patients received a Symax hip stem. RSA migration patterns of the Symax hip stem is presented here as a single cohort. RSA examinations were performed postoperatively, but before weight-bearing, and subsequently after 1, 3, 6, 12, and 24 months. Clinical outcomes and radiographic evaluations were assessed 3, 6, 12, and 24 months postoperatively.Results - During the first 4 weeks, the Symax hip stem subsided, rotated into retroversion, and translated posteriorly, after which the migration ceased and the prosthesis stabilized. All clinical outcomes improved from preoperatively to 2 years. There was no clinically or statistically significant correlation between subsidence and retroversion at 4 weeks and clinical outcomes after 2 years.Interpretation - RSA evaluation of the uncemented Symax hip stem confirms that the design principles and coating properties lead to early stabilization of the stem, as early as 4 weeks postoperatively. There was no correlation between subsidence and retroversion at 4 weeks and clinical outcomes after 2 years. Based on the predictive potential of the RSA technique, we anticipate excellent long-term survival of this hip stem.
Collapse
Affiliation(s)
- Dennis S M G Kruijntjens
- Department of Orthopaedic Surgery, Research School Caphri, Maastricht University Medical Centre, Maastricht; ,Correspondence:
| | - Lennard Koster
- Department of Orthopaedic Surgery, RSAcore, Leiden University Medical Centre, Leiden, the Netherlands
| | - Bart L Kaptein
- Department of Orthopaedic Surgery, RSAcore, Leiden University Medical Centre, Leiden, the Netherlands
| | - Liesbeth M C Jutten
- Department of Orthopaedic Surgery, Research School Caphri, Maastricht University Medical Centre, Maastricht;
| | - Jacobus J Arts
- Department of Orthopaedic Surgery, Research School Caphri, Maastricht University Medical Centre, Maastricht;
| | - René H M Ten Broeke
- Department of Orthopaedic Surgery, Research School Caphri, Maastricht University Medical Centre, Maastricht;
| |
Collapse
|
48
|
Critchley O, Callary S, Mercer G, Campbell D, Wilson C. Long-term migration characteristics of the Corail hydroxyapatite-coated femoral stem: a 14-year radiostereometric analysis follow-up study. Arch Orthop Trauma Surg 2020; 140:121-127. [PMID: 31655879 DOI: 10.1007/s00402-019-03291-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2019] [Indexed: 01/24/2023]
Abstract
BACKGROUND The magnitude and pattern of acceptable long-term migration of cementless femoral stems are not well understood. The Corail hydroxyapatite-coated cementless stem is a clinically successful and commonly used femoral stem with a long-term migration pattern not previously described in the literature. The aim of this study was to assess the long-term migration of the Corail hydroxyapatite-coated cementless stem using radiostereometric analysis (RSA) at 14-year follow-up, thereby establishing a benchmark acceptable long-term migration pattern for hydroxyapatite-coated cementless prostheses. MATERIALS AND METHODS A prospective cohort of 29 patients (30 hips) undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration of the Corail cementless stem. A total of 13 patients (4 males, 9 females) with mean age 82 (range 68-92) underwent repeat RSA radiographs at minimum 10 years post-operation (mean 13.9 years, range 13.3-14.4). Subsidence of the stem was measured and compared to prior measurements taken at 6 months and 1, 2, and 6 years. RESULTS None of the 13 patients have been revised. The migration at 6 months, 1 year, 2 years, and 6 years has been previously recorded. At mean 14-year follow-up, the cohort mean subsidence of the cementless stem was 0.70 mm (range - 0.06 to 3.61 mm). For each stem followed up at 6 months and 14 years, the mean subsidence over this period was 0.05 mm (range - 0.14 to 0.57 mm). There is no significant difference in mean subsidence at 6 months and 14 years (p = 0.43). CONCLUSIONS The long-term pattern of the subsidence of the Corail femoral stem has not previously been described. Subsidence occurs within the first 6 months, after which there is persistent stabilisation of the implant to 14 years. This study provides a description of a long-term acceptable migration pattern to which new hydroxyapatite-coated cementless prostheses may be compared. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Owain Critchley
- Department of Orthopaedics and Trauma Surgery, Flinders University, Adelaide, SA, Australia.,Department of Orthopaedics and Trauma, Flinders Medical Centre, Flinders Drive, Bedford Park, Adelaide, SA, 5042, Australia
| | - Stuart Callary
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia.,Centre for Orthopaedic and Trauma Research, University of Adelaide, Adelaide, SA, Australia
| | - Graham Mercer
- Department of Orthopaedics, Repatriation General Hospital, Adelaide, SA, Australia
| | - David Campbell
- Wakefield Orthopaedic Clinic, 270 Wakefield Street, Adelaide, SA, Australia
| | - Christopher Wilson
- Department of Orthopaedics and Trauma Surgery, Flinders University, Adelaide, SA, Australia. .,Department of Orthopaedics and Trauma, Flinders Medical Centre, Flinders Drive, Bedford Park, Adelaide, SA, 5042, Australia.
| |
Collapse
|
49
|
Aro HT, Nazari-Farsani S, Vuopio M, Löyttyniemi E, Mattila K. Effect of Denosumab on Femoral Periprosthetic BMD and Early Femoral Stem Subsidence in Postmenopausal Women Undergoing Cementless Total Hip Arthroplasty. JBMR Plus 2019; 3:e10217. [PMID: 31687650 PMCID: PMC6820573 DOI: 10.1002/jbm4.10217] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 06/21/2019] [Accepted: 06/25/2019] [Indexed: 12/11/2022] Open
Abstract
Antiresorptive denosumab is known to improve the quality and strength of cortical bone in the proximal femurs of osteoporotic women, but its efficacy in preventing periprosthetic bone loss and reducing femoral stem migration has not been studied in women undergoing cementless total hip arthroplasty. We conducted a single-center, randomized, double-blinded, placebo-controlled trial of 65 postmenopausal women with primary hip osteoarthritis and Dorr type A or B proximal femur anatomy. The patients randomly received subcutaneous injections of denosumab 60 mg or placebo once every 6 months for 12 months, starting 1 month before surgery. The primary endpoint was the change in bone mineral density (BMD) of the proximal femur (Gruen zone 7) at week 48, and the secondary endpoint was stem subsidence measured by radiostereometric analysis (RSA) at week 48. Exploratory endpoints included changes in BMDs of the contralateral hip, lumbar spine and distal radius, serum levels of bone turnover markers, walking speed, walking activity, patient-reported outcome measures, and radiographic assessment of stem osseointegration. The participants underwent vertebral-fracture assessment in an extension safety study at 3 years. Denosumab significantly decreased bone loss in the medial femoral neck (zone 7) and increased periprosthetic BMD in the greater trochanteric region (zone 1) and lesser trochanteric region (zone 6). Denosumab did not reduce temporary femoral stem migration. The migration occurred mainly during the settling period (0 to 12 weeks) after implantation of the prosthesis. All of the stems osseointegrated, as evaluated by RSA and radiographs. There were no intergroup differences in functional recovery. Discontinuation of denosumab did not lead to any adverse events. In conclusion, denosumab increased periprosthetic BMD in the clinically relevant regions of the proximal femur, but the treatment response was not associated with any reduction of initial stem migration. © 2019 The Authors. JBMR Plus published by Wiley Periodicals, Inc. on behalf of the American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Hannu T Aro
- Departments of Orthopaedic Surgery and Traumatology Turku University Hospital and University of Turku Turku Finland
| | - Sanaz Nazari-Farsani
- Departments of Orthopaedic Surgery and Traumatology Turku University Hospital and University of Turku Turku Finland
| | - Mia Vuopio
- Departments of Orthopaedic Surgery and Traumatology Turku University Hospital and University of Turku Turku Finland
| | - Eliisa Löyttyniemi
- Unit of Biostatistics, Department of Clinical Medicine University of Turku Turku Finland
| | - Kimmo Mattila
- Department of Diagnostic Imaging Turku University Hospital Turku Finland
| |
Collapse
|
50
|
Jørgensen PB, Lamm M, Søballe K, Stilling M. Equivalent hip stem fixation by Hi-Fatigue G and Palacos R + G bone cement: a randomized radiostereometric controlled trial of 52 patients with 2 years' follow-up. Acta Orthop 2019; 90:237-242. [PMID: 30931663 PMCID: PMC6534245 DOI: 10.1080/17453674.2019.1595390] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Long-term fixation of cemented femoral stems relies on several factors including cement adhesion and fatigue. Hi-Fatigue is a newer third-generation bone cement with low-viscosity properties at room temperature, good mechanical strength, and stable bone-cement interface in a laboratory testing environment. Palacos bone cement has excellent 10-year survival and is considered gold standard. We compared stem subsidence after fixation with Hi-Fatigue and Palacos bone cements using radiostereometry. Patients and methods - In a patient-blinded randomized controlled trial, 52 patients (30 women) at mean age 76 years (71-87) with osteoarthrosis and no osteoporosis received Hi-Fatigue G or Palacos R + G cement fixation of collarless, polished, double-tapered stems (CPT). Tantalum beads were inserted in the periprosthetic bone. Supine stereoradiographs were obtained postoperatively, 3 months, 6 months, 1 year, and 2 years after surgery. Oxford Hip Score (OHS) and VAS pain were recorded preoperatively and 1 and 2 years after surgery. Cement working times and properties were registered. Results - At 2 years, mean stem subsidence of 1.12 mm (95% CI 0.96-1.29) for Hi-Fatigue and 1.19 mm (CI 1.03-1.34) for Palacos was similar. Likewise, stem version was comparable between cement groups. Mean OHS and VAS pain were similar between cement groups. Cement working times were similar between cement groups, but the mean curing time was longer for Hi-Fatigue (13.7 min) than for Palacos (11.6 min). Interpretation - We found similar and generally low migration of CPT femoral stems inserted with Hi-Fatigue and Palacos bone cement until 2 years' follow-up, which indicates a good long-term survival of polished taper femoral stems inserted with both cement types.
Collapse
Affiliation(s)
- Peter B Jørgensen
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark,Correspondence:
| | - Martin Lamm
- Department of Orthopedic Surgery, Aarhus University Hospital;;
| | - Kjeld Søballe
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark
| | - Maiken Stilling
- Department of Orthopedic Surgery, Aarhus University Hospital;; ,Department of Clinical Medicine, Aarhus University, Denmark
| |
Collapse
|