1
|
Pragmatic accuracy of an in-house loop-mediated isothermal amplification (LAMP) for diagnosis of pulmonary tuberculosis in a Thai community hospital. PLoS One 2020; 15:e0236496. [PMID: 32702008 PMCID: PMC7377475 DOI: 10.1371/journal.pone.0236496] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 07/07/2020] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND To improve the quality of diagnosing pulmonary tuberculosis (TB), WHO recommends the use of rapid molecular testing as an alternative to conventional microscopic methods. Loop-mediated isothermal amplification assay (LAMP test) is a practical and cost-effective nucleic amplification technique. We evaluated the pragmatic accuracy of an in-house LAMP assay for the diagnosis of TB in a remote health care setting where an advanced rapid molecular test is not available. METHODS A prospective diagnostic accuracy study was conducted. Patients with clinical symptoms suggestive of TB were consecutively enrolled from April to August 2016. Sputum samples were collected from each patient and were sent for microscopic examination (both acid-fast stain and fluorescence stain), in-house LAMP test, and TB culture. RESULTS One hundred and seven patients with TB symptoms were used in the final analysis. This included 50 (46.7%) culture-positive TB patients and 57 (53.3%) culture-negative patients. The overall sensitivity of the in-house LAMP based on culture positivity was 88.8% (95/107) with a 95%CI of 81.2-94.1. The sensitivity was 90.9% (40/44) with a 95%CI of 78.3-97.5 for smear-positive, culture-positive patients, and was 16.7% (1/6) with a 95%CI of 0.4-64.1 for smear-negative, culture-positive patients. The overall sensitivity of the in-house LAMP test compared to smear microscopy methods were not significantly different (p = 0.375). The specificity of the in-house LAMP based on non-TB patients (smear-negative, culture-negative) was 94.7% (54/57) with a 95%CI of 85.4-98.9. CONCLUSIONS The diagnostic accuracy of the in-house LAMP test in a community hospital was comparable to other previous reports in terms of specificity. The sensitivity of the in-house assay could be improved with better sputum processing and DNA extraction method.
Collapse
|
2
|
Thapa J, Maharjan B, Malla M, Fukushima Y, Poudel A, Pandey BD, Hyashida K, Gordon SV, Nakajima C, Suzuki Y. Direct detection of Mycobacterium tuberculosis in clinical samples by a dry methyl green loop-mediated isothermal amplification (LAMP) method. Tuberculosis (Edinb) 2019; 117:1-6. [PMID: 31378262 DOI: 10.1016/j.tube.2019.05.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 05/09/2019] [Accepted: 05/19/2019] [Indexed: 11/19/2022]
Abstract
The purpose of this study was to develop a simple visual methyl green (MeG) based dry loop-mediated isothermal amplification (LAMP) method for early detection of Mycobacterium tuberculosis (MTB) from clinical samples. We identified MeG as an indicator of a positive LAMP reaction, where a positive reaction gave a blue-green color while a negative reaction was colorless. The MeG MTB-LAMP system was further simplified by drying all reagents for ease of use, and was then validated for its ability to diagnose TB directly using Nepalese clinical samples. We evaluated the dry MeG MTB-LAMP with 69 new TB suspected samples from patients that did not have a confirmed history of TB treatment and found the sensitivity in culture positive samples as 92.8% (13/14) and specificity in culture negative samples as 96.3% (53/55). Our LAMP system has the potential to be a point of care test for early diagnosis of active TB in developing countries.
Collapse
Affiliation(s)
- Jeewan Thapa
- Department of Medical Laboratory Sciences, Faculty of Health Sciences, Hokkaido University, Kita-12 Nishi-5, Kita-ku, Sapporo, Hokkaido, 060-0812, Japan.
| | - Bhagwan Maharjan
- Division of Bioresources, Hokkaido University Research Center for Zoonosis Control, Kita 20 Nishi 10, Kita-ku, Sapporo, Hokkaido, 001-0020, Japan; German Nepal Tuberculosis Project, Kalimati, Kathmandu, Nepal; Healthy Nepal, Balkhu, Kathmandu, Nepal
| | - Meena Malla
- Shi-Gan International College of Science and Technology, Kathmandu, Nepal
| | - Yukari Fukushima
- Division of Bioresources, Hokkaido University Research Center for Zoonosis Control, Kita 20 Nishi 10, Kita-ku, Sapporo, Hokkaido, 001-0020, Japan
| | - Ajay Poudel
- Department of Microbiology, Chitwan Medical College Teaching Hospital, Chitwan, Nepal
| | | | - Kyoko Hyashida
- Division of Collaboration and Education, Hokkaido University Research Center for Zoonosis Control, Kita 20 Nishi 10, Kita-ku, Sapporo, Hokkaido, 001-0020, Japan
| | - Stephen V Gordon
- UCD School of Veterinary Medicine, University College Dublin, Dublin, D04 W6F6, Ireland; The Global Station for Zoonosis Control, Hokkaido University Global Institution for Collaborative Research and Education, Kita 20 Nishi 10, Kita-ku, Sapporo, Japan
| | - Chie Nakajima
- Division of Bioresources, Hokkaido University Research Center for Zoonosis Control, Kita 20 Nishi 10, Kita-ku, Sapporo, Hokkaido, 001-0020, Japan; The Global Station for Zoonosis Control, Hokkaido University Global Institution for Collaborative Research and Education, Kita 20 Nishi 10, Kita-ku, Sapporo, Japan
| | - Yasuhiko Suzuki
- Division of Bioresources, Hokkaido University Research Center for Zoonosis Control, Kita 20 Nishi 10, Kita-ku, Sapporo, Hokkaido, 001-0020, Japan; The Global Station for Zoonosis Control, Hokkaido University Global Institution for Collaborative Research and Education, Kita 20 Nishi 10, Kita-ku, Sapporo, Japan.
| |
Collapse
|
3
|
Sethi S, Dhaliwal L, Dey P, Kaur H, Yadav R, Sethi S. Loop-mediated isothermal amplification assay for detection of Mycobacterium tuberculosis complex in infertile women. Indian J Med Microbiol 2017; 34:322-7. [PMID: 27514954 DOI: 10.4103/0255-0857.188323] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
BACKGROUND Female genital tuberculosis (FGTB) has a profound impact on the reproductive health of patients including infertility. Conventional diagnostic techniques have low sensitivity and specificity as well as long turnaround time. There is a need of developing newer, rapid and practically adaptable technique, especially in low-income countries. OBJECTIVE To standardize and evaluate loop-mediated isothermal amplification (LAMP) technique for diagnosis of FGTB. METHODS A total of 300 endometrial biopsy samples from infertile females were subjected to Ziehl-Neelsen (ZN) staining, Lowenstein-Jensen culture, automated culture (BACTEC mycobacterial growth indicator tube), histopathological examination (HPE), nucleic acid amplification by polymerase chain reaction (PCR) and LAMP technique. Composite gold standard (either smear/culture/HPE/PCR positive) was considered for calculation of outcome parameters. RESULTS The observed sensitivities of ZN smear, culture, HPE, PCR and LAMP were 2.94%, 10.29%, 8.82%, 95.59% and 66.18%, respectively. Overall concordance between PCR and LAMP was 63%, which shows a good agreement. CONCLUSION This study is the first to evaluate LAMP in the diagnosis of FGTB and found it to be a rapid and convenient technique, especially in low resource endemic settings.
Collapse
Affiliation(s)
- S Sethi
- Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - L Dhaliwal
- Department of Obstetrics and Gynaecology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - P Dey
- Department of Cytology and Gynaecological Pathology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - H Kaur
- Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - R Yadav
- Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - S Sethi
- Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| |
Collapse
|
4
|
Diagnostic test accuracy of loop-mediated isothermal amplification assay for Mycobacterium tuberculosis: systematic review and meta-analysis. Sci Rep 2016; 6:39090. [PMID: 27958360 PMCID: PMC5153623 DOI: 10.1038/srep39090] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2016] [Accepted: 11/17/2016] [Indexed: 11/08/2022] Open
Abstract
Diagnostic test accuracy of the loop-mediated isothermal amplification (LAMP) assay for culture proven tuberculosis is unclear. We searched electronic databases for both cohort and case-control studies that provided data to calculate sensitivity and specificity. The index test was any LAMP assay including both commercialized kits and in-house assays. Culture-proven M. tuberculosis was considered a positive reference test. We included 26 studies on 9330 sputum samples and one study on 315 extra-pulmonary specimens. For sputum samples, 26 studies yielded the summary estimates of sensitivity of 89.6% (95% CI 85.6–92.6%), specificity of 94.0% (95% CI 91.0–96.1%), and a diagnostic odds ratio of 145 (95% CI 93–226). Nine studies focusing on Loopamp MTBC yielded the summary estimates of sensitivity of 80.9% (95% CI 76.0–85.1%) and specificity of 96.5% (95% CI 94.7–97.7%). Loopamp MTBC had higher sensitivity and lower specificity for smear-positive sputa compared to smear-negative sputa. In-house assays showed higher sensitivity and lower specificity compared to Loopamp MTBC. LAMP promises to be a useful test for the diagnosis of TB, however there is still need to improve the assay to make it simpler, cheaper and more efficient to make it competitive against other PCR methods already available.
Collapse
|
5
|
Yan L, Xiao H, Zhang Q. Systematic review: Comparison of Xpert MTB/RIF, LAMP and SAT methods for the diagnosis of pulmonary tuberculosis. Tuberculosis (Edinb) 2015; 96:75-86. [PMID: 26786658 DOI: 10.1016/j.tube.2015.11.005] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Revised: 09/29/2015] [Accepted: 11/17/2015] [Indexed: 11/17/2022]
Abstract
Technological advances in nucleic acid amplification have led to breakthroughs in the early detection of PTB compared to traditional sputum smear tests. The sensitivity and specificity of loop-mediated isothermal amplification (LAMP), simultaneous amplification testing (SAT), and Xpert MTB/RIF for the diagnosis of pulmonary tuberculosis were evaluated. A critical review of previous studies of LAMP, SAT, and Xpert MTB/RIF for the diagnosis of pulmonary tuberculosis that used laboratory culturing as the reference method was carried out together with a meta-analysis. In 25 previous studies, the pooled sensitivity and specificity of the diagnosis of tuberculosis were 93% and 94% for LAMP, 96% and 88% for SAT, and 89% and 98% for Xpert MTB/RIF. The I(2) values for the pooled data were >80%, indicating significant heterogeneity. In the smear-positive subgroup analysis of LAMP, the sensitivity increased from 93% to 98% (I(2) = 2.6%), and specificity was 68% (I(2) = 38.4%). In the HIV-infected subgroup analysis of Xpert MTB/RIF, the pooled sensitivity and specificity were 79% (I(2) = 72.9%) and 99% (I(2) = 64.4%). In the HIV-negative subgroup analysis for Xpert MTB/RIF, the pooled sensitivity and specificity were 72% (I(2) = 49.6%) and 99% (I(2) = 64.5%). LAMP, SAT and Xpert MTB/RIF had comparably high levels of sensitivity and specificity for the diagnosis of tuberculosis. The diagnostic sensitivity and specificity of three methods were similar, with LAMP being highly sensitive for the diagnosis of smear-positive PTB. The cost effectiveness of LAMP and SAT make them particularly suitable tests for diagnosing PTB in developing countries.
Collapse
Affiliation(s)
- Liping Yan
- Tuberculosis Clinic and Research Center, Shanghai Pulmonary Hospital, Tongji University School of Medicine, No. 507, Zhengmin Road, Shanghai 200433, China
| | - Heping Xiao
- Tuberculosis Clinic and Research Center, Shanghai Pulmonary Hospital, Tongji University School of Medicine, No. 507, Zhengmin Road, Shanghai 200433, China
| | - Qing Zhang
- Tuberculosis Clinic and Research Center, Shanghai Pulmonary Hospital, Tongji University School of Medicine, No. 507, Zhengmin Road, Shanghai 200433, China.
| |
Collapse
|
6
|
Li Y, Shi L, Pan A, Cao W, Chen X, Meng H, Yan H, Miyoshi SI, Ye L. Evaluation of real-time loop-mediated isothermal amplification (RealAmp) for rapid detection of Mycobacterium tuberculosis from sputum samples. J Microbiol Methods 2014; 104:55-8. [PMID: 24968954 DOI: 10.1016/j.mimet.2014.06.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2014] [Revised: 06/12/2014] [Accepted: 06/13/2014] [Indexed: 11/29/2022]
Abstract
Tuberculosis (TB) caused by Mycobacterium tuberculosis (MTB) leads to serious health problems as a chronic respiratory infectious disease. Here we established a real-time fluorescence loop-mediated isothermal amplification assay (RealAmp) using a portable ESE Quant tube scanner as a convenient rapid detection method for MTB. The method efficacy from sputum samples was further investigated, and the reaction time was only 20min with the detection limit low to 10(2)CFU/ml concentration of MTB. We assessed a total of 1067 samples by the RealAmp assay, comparing the results with smear microscopy and conventional culture methods. To examine whether the failure to detect TB by culturing is due to low sensitivity or true absence, we examined the culture negative samples by commercial real time PCR MTB detection kit, and the results were compared with RealAmp. The data showed that RealAmp assay had a higher positive rate than that of sputum smear and culture methods. RealAmp had a sensitivity of 96.70% and a specificity of 91.55% when compared with culture. In addition, its sensitivity and specificity were 95.29% and 86.88% respectively compared with examination of smear samples using light microscopy. The sensitivity of RealAmp in comparison to real time PCR was 98.25% and specificity was 99.11% in validation of culture negative samples. The present study revealed the newly established RealAmp assay as a convenient, efficient, sensitive and specific method that could be an alternative for rapid detection of MTB and a tool to validate culture and smear negative samples. Furthermore, the portability of the ESE Quant tube scanner also contributed to the promising application for grassroots and field detection of MTB.
Collapse
Affiliation(s)
- Yiming Li
- College of Light Industry and Food Sciences, South China University of Technology, 510640 Guangzhou, PR China
| | - Lei Shi
- College of Light Industry and Food Sciences, South China University of Technology, 510640 Guangzhou, PR China
| | - Anqi Pan
- College of Light Industry and Food Sciences, South China University of Technology, 510640 Guangzhou, PR China
| | - Weiwei Cao
- Guangzhou DE AOU Biotechnology Technology Co., Ltd., Innovation Building, Science Road, Guangzhou Science City, 510663 Guangzhou, PR China
| | - Xun Chen
- Guangzhou DE AOU Biotechnology Technology Co., Ltd., Innovation Building, Science Road, Guangzhou Science City, 510663 Guangzhou, PR China
| | - Hecheng Meng
- College of Light Industry and Food Sciences, South China University of Technology, 510640 Guangzhou, PR China
| | - He Yan
- College of Light Industry and Food Sciences, South China University of Technology, 510640 Guangzhou, PR China
| | - Shin-ichi Miyoshi
- Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama 700-8530, Japan
| | - Lei Ye
- College of Light Industry and Food Sciences, South China University of Technology, 510640 Guangzhou, PR China.
| |
Collapse
|
7
|
Yuan LY, Li Y, Wang M, Ke ZQ, Xu WZ. Rapid and effective diagnosis of pulmonary tuberculosis with novel and sensitive loop-mediated isothermal amplification (LAMP) assay in clinical samples: A meta-analysis. J Infect Chemother 2014; 20:86-92. [DOI: 10.1016/j.jiac.2013.07.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2013] [Revised: 06/24/2013] [Accepted: 07/25/2013] [Indexed: 11/29/2022]
|
8
|
Loop-mediated isothermal amplification for rapid and reliable diagnosis of tuberculous meningitis. J Clin Microbiol 2011; 49:1861-5. [PMID: 21411583 DOI: 10.1128/jcm.00824-10] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Diagnosis of tuberculous meningitis (TBM) is often difficult. A reliable, simple, and rapid diagnostic test that can be performed in any standard laboratory could be helpful in TBM diagnosis. In this study, a loop-mediated isothermal amplification assay (LAMP) was evaluated to rapidly detect and diagnose TBM infection and was compared to the performance of nested PCR. Six specific primers were used to recognize the IS6110 genomic sequence from Mycobacterium tuberculosis, which included one forward outer primer, one reverse outer primer, two respective inner primers, and two loop primers. The optimum reaction temperature and time were 63°C and 60 min, respectively. Nested PCR was performed targeting the IS6110 region from M. tuberculosis using a commercial kit. The LAMP method yielded a sensitivity of 88.23% and a specificity of 80%, compared to the nested-PCR assay, which yielded a sensitivity of 52.9% and a specificity of 90% for TBM diagnosis. Comparative experiments showed that the LAMP assay is a rapid, sensitive, and specific method to detect TBM infection and that it is superior to the nested-PCR assay. LAMP is very simple, and it can be performed in any laboratory and in rural settings.
Collapse
|
9
|
Geojith G, Dhanasekaran S, Chandran SP, Kenneth J. Efficacy of loop mediated isothermal amplification (LAMP) assay for the laboratory identification of Mycobacterium tuberculosis isolates in a resource limited setting. J Microbiol Methods 2010; 84:71-3. [PMID: 21047534 DOI: 10.1016/j.mimet.2010.10.015] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2010] [Revised: 10/05/2010] [Accepted: 10/21/2010] [Indexed: 10/18/2022]
Abstract
Current methods of TB diagnosis are time consuming and less suited for developing countries. The LAMP (loop mediated isothermal amplification) is a rapid method more suitable for diagnosis in resource limited settings and has been proposed as a viable test requiring further evaluation for use as a laboratory method as well. We evaluated two LAMP assays, using culture lysates of clinical sputum samples (from Southern India) and compared it to a proprietary multiplex PCR reverse-hybridization line probe assay ('GenoType MTBC' from HAIN Lifescience GmbH, Germany). The LAMP procedure was modified to suit the local conditions. The Mycobacterium tuberculosis specific LAMP assay ('MTB LAMP') showed sensitivity and specificity, of 44.7% and 94.4% respectively in a 60 min format, 85.7% and 93.9% respectively in a 90 min format and 91.7%, and 90.9% respectively in a 120 min format. The Mycobacteria universal LAMP assay ('Muniv LAMP') showed a sensitivity of 99.1%. The LAMP was shown to be a rapid and accessible assay for the laboratory identification of M. tuberculosis isolates. Initial denaturation of template was shown to be essential for amplification in unpurified/dilute samples and longer incubation was shown to increase the sensitivity. The need for modification of protocols to yield better efficacy in this scenario needs to be addressed in subsequent studies.
Collapse
Affiliation(s)
- G Geojith
- Infectious disease unit, St. John's Research Institute, Bangalore, India
| | | | | | | |
Collapse
|