1
|
Kim I, Ahn SJ, Park M, Joo B, Kim J, Suh SH. Diagnostic Performance of Pointwise Encoding Time Reduction with Radial Acquisition Subtraction-based MR Angiography in the Follow-up of Intracranial Aneurysms after Clipping. Clin Neuroradiol 2024:10.1007/s00062-024-01399-y. [PMID: 38456913 DOI: 10.1007/s00062-024-01399-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 02/12/2024] [Indexed: 03/09/2024]
Abstract
PURPOSE While follow-up assessment of clipped aneurysms (CAs) using magnetic resonance angiography (MRA) can be challenging due to susceptibility artifacts, a novel MRA sequence pointwise encoding time reduction with radial acquisition (PETRA) subtraction-based MRA, has been developed to reduce these artifacts. The aim of the study was to validate the diagnostic performance of PETRA-MRA by comparing it with digital subtraction angiography (DSA) as a reference for follow-up of CAs using a 3T MR scanner. METHODS Patients with clipping who underwent both PETRA-MRA and DSA between September 2019 and December 2021 were retrospectively included. Two neuroradiologists independently reviewed with the reconstructed images of PETRA-MRA to assess the visibility of the arteries around the clips and aneurysm recurrence or remnants of CA using a 3-point scale. The diagnostic accuracy of PETRA-MRA was evaluated in comparison to DSA. RESULTS The study included 34 patients (28 females, mean age 59 ± 9.6 years) with 48 CAs. The PETRA-MRA allowed visualization of the parent vessels around the clips in 98% of cases, compared to 39% with time-of-flight (TOF) MRA (p < 0.0001). The DSA confirmed 14 (29.2%) residual or recurrent aneurysms. The PETRA-MRA demonstrated a high accuracy, specificity, positive predictive value, and negative predictive value of 99.2%, 100%, 100%, and 97.8%, respectively, while the sensitivity was 66.7%. CONCLUSION This retrospective study demonstrates that PETRA-MRA provides excellent visibility of adjacent vessels near clips and has a high diagnostic accuracy in detecting aneurysm remnants or recurrences in CAs. Further prospective studies are warranted to establish its utility as a reliable alternative for follow-up after clipping.
Collapse
Affiliation(s)
- Inyoung Kim
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Sung Jun Ahn
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Mina Park
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Bio Joo
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Junhyung Kim
- Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Sang Hyun Suh
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of).
| |
Collapse
|
2
|
Leng Y, Liu Y, Li S, Wang X, Deng W, Wang Y, Gong L. Feasibility of using 8 mL of iodinated contrast media in cerebral computed tomographic angiography with a dual-layer spectral detector. Quant Imaging Med Surg 2024; 14:514-526. [PMID: 38223031 PMCID: PMC10784050 DOI: 10.21037/qims-23-914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Accepted: 10/24/2023] [Indexed: 01/16/2024]
Abstract
Background Virtual monoenergetic images (VMIs) at a low energy level can improve image quality when the amount of iodinated contrast media (CM) is reduced. The purpose was to evaluate the feasibility of using an extremely low CM volume and injection rate in cerebral computed tomography angiography (CTA) on a dual-layer spectral detector computed tomography (CT). Methods Patients who were clinically suspected of intracranial aneurysm or cerebrovascular diseases were included in our study (from June to November 2022). In this prospective study, 80 patients were randomly enrolled into group A (8 mL of CM with a 1-mL/s flow rate) or group B (40 mL of CM with 4-mL/s flow rate). The VMIs at 40-70 keV in group A and polychromatic conventional images in the 2 groups were reconstructed. CT attenuation, image noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were evaluated via the t-test or Mann-Whitney test (2 groups), while analysis of variance or Kruskal-Wallis test (multiple groups). Subjective image quality was assessed on a 5-point scale. Results In group A, the subjective image quality score, CT attenuation, and CNR of the internal carotid artery (ICA) and middle cerebral artery (MCA) were the highest on VMIs at 40 keV. The image noise on VMIs at 40 keV was 5.08±0.84 Hounsfield units. The subjective image quality score, CT value of the ICA, MCA, and cerebral parenchyma on VMIs at 40 keV in group A were similar to those in group B (all P values >0.05). Compared to those in group B, the VMIs at 40 keV in group A demonstrated a significantly higher mean SNR and CNR of the ICA (mean SNR: 46.22±20.18 vs. 34.32±12.40, P=0.002; CNR: 55.47±13.43 vs. 46.18±12.30, P=0.002) and MCA [SNR: 13.66 (9.78, 20.29) vs. 9.99 (7.53, 14.00), P=0.003; CNR: 47.00±12.71 vs. 39.45±10.47, P=0.005]. Conclusions Cerebral CTA on VMIs at 40 keV with 8 mL of CM and a 1-mL/s injection rate can provide diagnostic image quality.
Collapse
Affiliation(s)
- Yinping Leng
- Department of Radiology, the Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Ying Liu
- Department of Radiology, the Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Shuhao Li
- Department of Radiology, the Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Xiwen Wang
- Department of Radiology, the Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Weiwei Deng
- Clinical and Technical Support, Philips Healthcare, Shanghai, China
| | - Yu Wang
- Clinical and Technical Support, Philips Healthcare, Shanghai, China
| | - Lianggeng Gong
- Department of Radiology, the Second Affiliated Hospital of Nanchang University, Nanchang, China
| |
Collapse
|
3
|
Kim JH, Ahn SJ, Park M, Kim YB, Joo B, Lee W, Suh SH. Follow-up imaging of clipped intracranial aneurysms with 3-T MRI: comparison between 3D time-of-flight MR angiography and pointwise encoding time reduction with radial acquisition subtraction-based MR angiography. J Neurosurg 2022; 136:1260-1265. [PMID: 34715654 DOI: 10.3171/2021.7.jns211197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Accepted: 07/01/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Metallic susceptibility artifact due to implanted clips is a major limitation of using 3D time-of-flight magnetic resonance angiography (TOF-MRA) for follow-up imaging of clipped aneurysms (CAs). The purpose of this study was to compare pointwise encoding time reduction with radial acquisition (PETRA) subtraction-based MRA with TOF-MRA in terms of imaging quality and visibility of clip-adjacent arteries for use in follow-up imaging of CAs. METHODS Sixty-two patients with 73 CAs were included retrospectively in this comparative study. All patients underwent PETRA-MRA after TOF-MRA performed simultaneously with 3-T MRI between September 2019 and March 2020. Two neuroradiologists independently compared images obtained with both MRA modalities to evaluate overall image quality using a 4-point scale and visibility of the parent artery and branching vessels near the clips using a 3-point scale. Subgroup analysis was performed according to the number of clips (less-clipped [1-2 clips] vs more-clipped [≥ 3 clips] aneurysms). The ability to detect aneurysm recurrence was also assessed. RESULTS Compared with TOF-MRA, PETRA-MRA showed acceptable image quality (score of 3.97 ± 0.18 for TOF-MRA vs 3.73 ± 0.53 for PETRA-MRA) and had greater visibility of the adjacent vessels near the CAs (score of 1.25 ± 0.59 for TOF-MRA vs 2.27 ± 0.75 for PETRA-MRA, p < 0.0001). PETRA-MRA had greater visibility of vessels adjacent to less-clipped aneurysms (score of 2.39 ± 0.75 for less-clipped aneurysms vs 2.09 ± 0.72 for more-clipped aneurysms, p = 0.014). Of 73 CAs, aneurysm recurrence in 4 cases was detected using PETRA-MRA. CONCLUSIONS This study demonstrated that PETRA-MRA is superior to TOF-MRA for visualizing adjacent vessels near clips and can be an advantageous alternative to TOF-MRA for follow-up imaging of CAs.
Collapse
Affiliation(s)
- Jae Ho Kim
- 1Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea; and
| | - Sung Jun Ahn
- 2Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Mina Park
- 2Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Yong Bae Kim
- 1Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea; and
| | - Bio Joo
- 2Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Woosung Lee
- 1Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea; and
| | - Sang Hyun Suh
- 2Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
4
|
Repeated Aneurysm Intervention. Adv Tech Stand Neurosurg 2022; 44:277-296. [PMID: 35107686 DOI: 10.1007/978-3-030-87649-4_16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Over the past 25 years the endovascular treatment of cerebral aneurysms has gained preference in some countries over the traditional surgical procedures. The review part of the article clearly demonstrates that the clinical results of both modalities are similar and the difference is seen only in technical effectivity. Surgical techniques fail far less frequently than the endovascular ones. Incompletely occluded or growing aneurysms after the endovascular approach expose the patient to the risk of rebleeding with all possible consequences. Markedly repeated procedures are much more common for endovascularly treated aneurysms, again with all the risks.In the authors institution over the past 20 years, a total of 2032 aneurysms were treated. In 1263 endovascularly managed aneurysms the regrowth or inclomplete initial occlusion necessitated 159 repeated propcedures (12.6%). In surgical group the total of 27 aneurysms needed retreatment (3.5%). The difference is statistically significant. In nine patients in endovascular group the rebleeding was the reason for repeated procedures. No rebleeding was seen in the surgical group.This fact, also shown in the review part of the article, is important in patients counseling. Given the similar clinical results of both modalities the patient should be advised on the necessity of repeated follow-ups and of possible technical failure and eventual repeated procedure which is more likely if endovascular procedure is chosen.
Collapse
|
5
|
Benomar A, Farzin B, Gevry G, Boisseau W, Roy D, Weill A, Iancu D, Guilbert F, Létourneau-Guillon L, Jacquin G, Chaalala C, Bojanowski MW, Labidi M, Fahed R, Volders D, Nguyen TN, Gentric JC, Magro E, Boulouis G, Forestier G, Hak JF, Ghostine JS, Kaderali Z, Shankar JJ, Kotowski M, Darsaut TE, Raymond J. Noninvasive Angiographic Results of Clipped or Coiled Intracranial Aneurysms: An Inter- and Intraobserver Reliability Study. AJNR Am J Neuroradiol 2021; 42:1615-1620. [PMID: 34326106 DOI: 10.3174/ajnr.a7236] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Accepted: 04/28/2021] [Indexed: 01/16/2023]
Abstract
BACKGROUND AND PURPOSE Noninvasive angiography is commonly used to assess the outcome of surgical or endovascular treatment of intracranial aneurysms in clinical series or randomized trials. We sought to assess whether a standardized 3-grade classification system could be reliably used to compare the CTA and MRA results of both treatments. MATERIALS AND METHODS An electronic portfolio composed of CTAs of 30 clipped and MRAs of 30 coiled aneurysms was independently evaluated by 24 raters of diverse experience and training backgrounds. Twenty raters performed a second evaluation 1 month later. Raters were asked which angiographic grade and management decision (retreatment; close or long-term follow-up) would be most appropriate for each case. Agreement was analyzed using the Krippendorff α (αK) statistic, and the relationship between angiographic grade and clinical management choice, using the Fisher exact and Cramer V tests. RESULTS Interrater agreement was substantial (αK = 0.63; 95% CI, 0.55-0.70); results were slightly better for MRA results of coiling (αK = 0.69; 95% CI, 0.56-0.76) than for CTA results of clipping (αK = 0.58; 95% CI, 0.44-0.69). Intrarater agreement was substantial to almost perfect. Interrater agreement regarding clinical management was moderate for both clipped (αK = 0.49; 95% CI, 0.32-0.61) and coiled subgroups (αK = 0.47; 95% CI, 0.34-0.54). The choice of clinical management was strongly associated with the size of the residuum (mean Cramer V = 0.77 [SD, 0.14]), but complete occlusions (grade 1) were followed more closely after coiling than after clipping (P = .01). CONCLUSIONS A standardized 3-grade scale was found to be a reliable and clinically meaningful tool to compare the results of clipping and coiling of aneurysms using CTA or MRA.
Collapse
Affiliation(s)
- A Benomar
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - B Farzin
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - G Gevry
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - W Boisseau
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - D Roy
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - A Weill
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - D Iancu
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - F Guilbert
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - L Létourneau-Guillon
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| | - G Jacquin
- Department of Medicine, Division of Neurology (G.J.)
| | - C Chaalala
- Division of Neurosurgery (C.C., M.W.B., M.L.), Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada
| | - M W Bojanowski
- Division of Neurosurgery (C.C., M.W.B., M.L.), Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada
| | - M Labidi
- Division of Neurosurgery (C.C., M.W.B., M.L.), Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada
| | - R Fahed
- Division ofNeurology (R.F.), The Ottawa Hospital Ottawa, Ontario, Canada
| | - D Volders
- Department of Diagnostic Radiology (D.V.), Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada
| | - T N Nguyen
- Departments of Neurology, Neurosurgery, and Radiology (T.N.N.), Boston Medical Center, Boston, Massachusetts
| | - J-C Gentric
- Departments of Interventional Neuroradiology (J.-C.G.)
| | - E Magro
- Neurosurgery (E.M.), Hôpital de la Cavale Blanche, Centre Hospitalier Régional et Universitaire de Brest, Brest, France
| | - G Boulouis
- Department of Neuroradiology (G.B.), Centre Hospitalier Régional et Universitaire de Tours, Tours, France
| | - G Forestier
- Department of Neuroradiology (G.F.), University Hospital of Limoges, Limoges, France
| | - J-F Hak
- Department of Medical Imaging (J.-F.H.), University Hospital Timone Assistance Publique - Hôpitaux de Marseille, Marseille, France
| | - J S Ghostine
- Department of Radiology (J.S.G.), Jean-Talon Hospital, Montreal, Quebec, Canada
| | | | - J J Shankar
- Department of Radiology (J.J.S.), Health Sciences Centre, Winnipeg, Manitoba, Canada
| | - M Kotowski
- Department of Neurosurgery (M.K.), Hôpital de la Providence, Neuchâtel, Switzerland
| | - T E Darsaut
- Department of Surgery (T.E.D.), Division of Neurosurgery,Walter C. Mackenzie Health Sciences Centre, University of Alberta Hospital, Edmonton, Alberta, Canada
| | - J Raymond
- From the Department of Radiology (A.B., B.F., G.G., W.B., D.R., A.W., D.I., F.G., L.L.-G., J.R.)
| |
Collapse
|
6
|
Noncontrast Magnetic Resonance Angiography in the Era of Nephrogenic Systemic Fibrosis and Gadolinium Deposition. J Comput Assist Tomogr 2021; 45:37-51. [PMID: 32976265 DOI: 10.1097/rct.0000000000001074] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
ABSTRACT Gadolinium-based contrast agents for clinical magnetic resonance imaging are overall safe. However, the discovery of nephrogenic systemic fibrosis in patients with severe renal impairment and gadolinium deposition in patients receiving contrast have generated developments in contrast-free imaging of the vasculature, that is, noncontrast magnetic resonance angiography. This article presents an update on noncontrast magnetic resonance angiography techniques, with comparison to other imaging alternatives. Potential benefits and challenges to implementation, and evidence to date for various clinical applications are discussed.
Collapse
|
7
|
Marbacher S, Kienzler JC, Mendelowitsch I, D'Alonzo D, Andereggen L, Diepers M, Remonda L, Fandino J. Comparison of Intra- and Postoperative 3-Dimensional Digital Subtraction Angiography in Evaluation of the Surgical Result After Intracranial Aneurysm Treatment. Neurosurgery 2021; 87:689-696. [PMID: 31748795 DOI: 10.1093/neuros/nyz487] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 08/20/2019] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Postoperative three-dimensional digital subtraction angiography (3D-DSA) is the gold standard in evaluating intracranial aneurysm (IA) remnants after clipping. Should intraoperative 3D-DSA image quality be equally good as postoperative 3D-DSA, it could supplant the latter as standard of care for follow-up of clipped IA. OBJECTIVE To directly compare the quality of assessment of clipped IA by intraoperative and postoperative 3D-DSA. METHODS From a prospective cohort of 221 consecutive patients who underwent craniotomy for IA treatment in a hybrid operating room, we retrospectively studied 26 patients who had both intraoperative and postoperative 3D-DSA imaging of their clipped aneurysm. Comparison of intraoperative and postoperative 3D-DSA images (blinded for review) included parameters that affected image quality and differences between the 2 periods. RESULTS In the 26 patients with 32 clipped IAs, the mean interval was 11 ± 7 mo between intraoperative and postoperative imaging 3D-DSA examinations. Reconstruction with multiple clips was used in 14 (44%) cases. Of 15 remnants, 9 (60%) were small (<2 mm). In comparing intraoperative and postoperative 3D-DSA, no discordance or discrepancy in assessment of the surgical result was noted for any clipped IA, and overall imaging quality was excellent for both modalities. Factors affecting minor differences in image quality were not identified. CONCLUSION Compared with postoperative 3D-DSA, intraoperative 3D-DSA images achieved equally high quality and effective, immediate interpretation of the surgical clipping result. With comparable imaging quality and no discordant findings, intraoperative 3D-DSA could replace postoperative 3D-DSA to become the standard of care in IA surgery.
Collapse
Affiliation(s)
- Serge Marbacher
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| | - Jenny C Kienzler
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| | | | - Donato D'Alonzo
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| | - Lukas Andereggen
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| | - Michael Diepers
- Division of Neuroradiology, Department of Radiology, Kantonsspital Aarau, Aarau, Switzerland
| | - Luca Remonda
- Division of Neuroradiology, Department of Radiology, Kantonsspital Aarau, Aarau, Switzerland
| | - Javier Fandino
- Department of Neurosurgery, Kantonsspital Aarau, Aarau, Switzerland
| |
Collapse
|
8
|
Songsaeng D, Sakarunchai I, Mongkolnaowarat S, Harmontree S, Pornpunyawut P, Suwanbundit A, Zhang S, Krings T. Detection and Measurement of Intracranial Aneurysm Compared between Magnetic Resonance Intracranial Black Blood Vessel Imaging and Gold Standard Cerebral Digital Subtraction Angiography. J Neurosci Rural Pract 2020; 11:545-551. [PMID: 33144789 PMCID: PMC7595774 DOI: 10.1055/s-0040-1714042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
Abstract
Background Magnetic resonance intracranial black blood vessel imaging (MR-IBBVI) is a new noninvasive method for evaluating intracranial vessel wall pathology. No previous studies have investigated the efficacy of MR-IBBVI to determine aneurysm size. We aimed to identify the precise diagnosis of MR-IBBVI for the detection and measurement of intracranial aneurysm compared with gold standard cerebral digital subtraction angiography (cDSA). Materials and Methods The retrospective study collected patients of precoiled or postcoiled intracranial aneurysm who were treated at our institute from January 2012 to June 2019 and who had MR-IBBVI, cDSA imaging, and/or three-dimensional time-of-flight sequence of magnetic resonance angiography. The sensitivity and specificity of aneurysm detection by MR-IBBVI and the accuracy of MR-IBBVI for measuring the aneurysm and vessel size were calculated. Results One hundred and twenty patients (61% female) with 132 aneurysms were included into this study. The mean aneurysm size was 5.3 mm (range: 2.2-22.6). Sensitivity and specificity of MR-IBBVI to detect a small aneurysm were 98.74 and 91.21%, respectively. No statistically significant results were observed between MR-IBBVI and DSA for aneurysm detection or any of the evaluated measurement parameters. Conclusion MR-IBBVI is an accurate and highly sensitive method to detect and evaluate the size of an intracranial aneurysm both before and after coiling.
Collapse
Affiliation(s)
- Dittapong Songsaeng
- Department of Radiology, Division of Diagnostic Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Ittichai Sakarunchai
- Department of Surgery, Division of Neurosurgery, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand
| | - Sakun Mongkolnaowarat
- Department of Radiology, Division of Diagnostic Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Sasithorn Harmontree
- Department of Radiology, Division of Diagnostic Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Prapaporn Pornpunyawut
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Anek Suwanbundit
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Shuo Zhang
- Philips Healthcare, Toa Payoh, Singapore
| | - Timo Krings
- Department of Medical Imaging, Division of Neuroradiology, Faculty of Medicine, University of Toronto, Canada
| |
Collapse
|
9
|
Ryu KH, Baek HJ, Moon JI, Choi BH, Park SE, Ha JY, Park H, Kim SS, Kim JS, Cho SB, Carl M. Usefulness of Noncontrast-Enhanced Silent Magnetic Resonance Angiography (MRA) for Treated Intracranial Aneurysm Follow-up in Comparison with Time-of-Flight MRA. Neurosurgery 2019; 87:220-228. [DOI: 10.1093/neuros/nyz421] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 07/29/2019] [Indexed: 11/14/2022] Open
Abstract
Abstract
BACKGROUND
Flow visualization in time-of-flight magnetic resonance angiography (TOF MRA) is limited for treated intracranial aneurysms owing to magnetic susceptibility and radiofrequency shielding.
OBJECTIVE
To assess the clinical usefulness of noncontrast-enhanced magnetic resonance angiography (MRA) using a silent scan (silent MRA) as a follow-up imaging modality in patients with treated intracranial aneurysms.
METHODS
A total of 119 patients with 126 treated aneurysms underwent silent MRA and TOF MRA during the same scan session. Two neuroradiologists independently assessed overall image quality and visualization of the treated site using a 5-point Likert scale to compare the 2 image sets. We used receiver operating characteristic (ROC) curve analysis to investigate the diagnostic performance of the 2 MRA methods in evaluating aneurysm occlusion. Interobserver reliability was also assessed using weighted kappa statistics.
RESULTS
The overall image quality scores of silent MRA and TOF MRA were 4.04 ± 0.22 and 4.64 ± 0.48, respectively (P < .001), and interobserver agreement was substantial (P < .001). For the treated site, the score of flow visualization on silent MRA was higher than that on TOF MRA, 3.94 ± 0.94 vs 2.59 ± 1.37 (P < .001), with substantial interobserver agreement (P < .001). ROC curve analysis showed that silent MRA was superior to TOF MRA in diagnostic performance (area under the curve [AUC] = 0.962; 95% CI: 0.931-0.982 vs AUC = 0.843; 95% CI: 0.792-0.886; P < .001).
CONCLUSION
Silent MRA can be useful to evaluate treated intracranial aneurysms during follow-up without radiation exposure and use of contrast material. It is characterized by higher diagnostic performance and superior visualization for the treated site.
Collapse
Affiliation(s)
- Kyeong Hwa Ryu
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
| | - Hye Jin Baek
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
- Department of Radiology, Gyeongsang National University School of Medicine, Jinju, Republic of Korea
| | - Jin Il Moon
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
| | - Bo Hwa Choi
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
- Department of Radiology, Gyeongsang National University School of Medicine, Jinju, Republic of Korea
| | - Sung Eun Park
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
| | - Ji Young Ha
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
| | - Hyun Park
- Department of Neurosurgery, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
- Department of Neurosurgery, Gyeongsang National University School of Medicine, Jinju, Republic of Korea
| | - Seung Soo Kim
- Department of Neurosurgery, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
| | - Jung-Soo Kim
- Department of Neurosurgery, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
| | - Soo Buem Cho
- Department of Radiology, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
| | - Michael Carl
- Applied Science Lab, GE Healthcare, San Diego, CA, United States
| |
Collapse
|
10
|
Dundar TT, Aralasmak A, Kitiş S, Yılmaz FT, Abdallah A. Comparison of Subtracted Computed Tomography from Computed Tomography Perfusion and Digital Subtraction Angiography in Residue Evaluation of Treated Intracranial Aneurysms. World Neurosurg 2019; 132:e746-e751. [PMID: 31415894 DOI: 10.1016/j.wneu.2019.08.028] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Revised: 08/04/2019] [Accepted: 08/05/2019] [Indexed: 12/01/2022]
Abstract
BACKGROUND Assessing clipped intracranial aneurysms for residues or incomplete occlusions is critical. Digital subtraction angiography (DSA) has been the gold standard for this. Previously, we presented subtracted computed tomography angiography (sub-CTA) from computed tomography perfusion as a more effective noninvasive technique for clipped aneurysms. The aim of this study was to compare effectiveness of sub-CTA with DSA in residue evaluation. METHODS A retrospective study of 17 patients with aneurysmal subarachnoid hemorrhage operated on at our institution between November 1, 2016, and December 31, 2018, was performed. Residue aneurysms were evaluated with both sub-CTA and DSA. Positive predictive value and negative predictive value were calculated. Correlation between techniques was determined by the McNemar test and κ value. RESULTS Sensitivity of sub-CTA in residue evaluation was low in aneurysms ≤3 mm (positive predictive value = 60%). DSA detected residue aneurysm in 29% (5/17) of patients, whereas sub-CTA detected residue aneurysm in 11% (2/17). Only 40% of aneurysms (2/5) were demonstrated by sub-CTA, all >3 mm; 60% (3/5) were missed, all ≤3 mm. CONCLUSIONS This is the first study comparing the effectiveness of sub-CTA from computed tomography perfusion with DSA in residue aneurysm evaluation. Our results were suggestive, but not conclusive. DSA is still the gold standard in residue evaluation. Sub-CTA from computed tomography perfusion can be a reliable method in evaluation of residual aneurysm >3 mm.
Collapse
Affiliation(s)
- Tolga Turan Dundar
- Department of Neurosurgery, Faculty of Medicine, Bezmi Alem University, İstanbul, Turkey.
| | - Ayse Aralasmak
- Department Radiology, Faculty of Medicine, Bezmi Alem University, İstanbul, Turkey
| | - Serkan Kitiş
- Department of Neurosurgery, Faculty of Medicine, Bezmi Alem University, İstanbul, Turkey
| | - Fatih Temel Yılmaz
- Department Radiology, Faculty of Medicine, Bezmi Alem University, İstanbul, Turkey
| | - Anas Abdallah
- Department of Neurosurgery, Faculty of Medicine, Bezmi Alem University, İstanbul, Turkey
| |
Collapse
|
11
|
Kuroda H, Toyota S, Kumagai T, Iwata T, Kobayashi M, Mori K, Taki T. Feasibility of Smart Metal Artifact Reduction Algorithm on Computed Tomography Angiography for Clipping of Recurrent Aneurysms After Coil Embolization. World Neurosurg 2019; 127:e1249-e1254. [PMID: 31026660 DOI: 10.1016/j.wneu.2019.04.133] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Revised: 04/14/2019] [Accepted: 04/15/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND The number of patients with a history of clipping of recurrent aneurysms after coil embolization has increased. The aim of this article was to report the feasibility of CT angiography using a commercial metal artifact reduction algorithm (Smart Metal Artifact Reduction [MAR]) for patients who underwent clipping of recurrent aneurysms after coil embolization. METHODS Six cases of clipping of recurrent aneurysms after coil embolization were examined with CT angiography using MAR between 2015 and 2018 at a single institution. Conventional CT angiography and three-dimensional digital subtraction angiography data were compared, and depiction of the status of treated aneurysms using MAR was estimated. RESULTS Conventional CT angiography was unable to depict the status of treated aneurysms in the patients with a history of clipping of recurrent aneurysms after coil embolization because of metal artifacts. With MAR, metal artifacts were greatly reduced, and the status of treated aneurysms was able to be depicted, although depiction was inferior to three-dimensional digital subtraction angiography. CONCLUSIONS For patients with a history of clipping of recurrent aneurysms after coil embolization, CT angiography using MAR is feasible, although further development of imaging techniques is needed.
Collapse
Affiliation(s)
- Hideki Kuroda
- Department of Neurosurgery, Kansai Rosai Hospital, Hyogo, Japan
| | - Shingo Toyota
- Department of Neurosurgery, Kansai Rosai Hospital, Hyogo, Japan.
| | - Tetsuya Kumagai
- Department of Neurosurgery, Kansai Rosai Hospital, Hyogo, Japan
| | - Takamitsu Iwata
- Department of Neurosurgery, Kansai Rosai Hospital, Hyogo, Japan
| | - Maki Kobayashi
- Department of Neurosurgery, Kansai Rosai Hospital, Hyogo, Japan
| | - Kanji Mori
- Department of Neurosurgery, Kansai Rosai Hospital, Hyogo, Japan
| | - Takuyu Taki
- Department of Neurosurgery, Kansai Rosai Hospital, Hyogo, Japan
| |
Collapse
|
12
|
Yun SY, Heo YJ, Jeong HW, Baek JW, Choo HJ, Shin GW, Kim ST, Jeong YG, Lee JY, Jung HS. Dual-energy CT angiography-derived virtual non-contrast images for follow-up of patients with surgically clipped aneurysms: a retrospective study. Neuroradiology 2019; 61:747-755. [DOI: 10.1007/s00234-019-02170-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 01/15/2019] [Indexed: 11/29/2022]
|
13
|
Mocanu I, Van Wettere M, Absil J, Bruneau M, Lubicz B, Sadeghi N. Value of dual-energy CT angiography in patients with treated intracranial aneurysms. Neuroradiology 2018; 60:1287-1295. [DOI: 10.1007/s00234-018-2090-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Accepted: 08/23/2018] [Indexed: 10/28/2022]
|
14
|
Sunwoo L, Park SW, Rhim JH, Kang Y, Chung YS, Son YJ, Kim SC. Metal Artifact Reduction for Orthopedic Implants: Brain CT Angiography in Patients with Intracranial Metallic Implants. J Korean Med Sci 2018; 33:e158. [PMID: 29780296 PMCID: PMC5955738 DOI: 10.3346/jkms.2018.33.e158] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2018] [Accepted: 03/26/2018] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND The purpose of this study was to qualitatively and quantitatively evaluate the effects of a metal artifact reduction for orthopedic implants (O-MAR) for brain computed tomographic angiography (CTA) in patients with aneurysm clips and coils. METHODS The study included 36 consecutive patients with 47 intracranial metallic implants (42 aneurysm clips, 5 coils) who underwent brain CTA. The computed tomographic images with and without the O-MAR were independently reviewed both quantitatively and qualitatively by two reviewers. For quantitative analysis, image noises near the metallic implants of non-O-MAR and O-MAR images were compared. For qualitative analysis, image quality improvement and the presence of new streak artifacts were assessed. RESULTS Image noise was significantly reduced near metallic implants (P < 0.01). Improvement of implant-induced streak artifacts was observed in eight objects (17.0%). However, streak artifacts were aggravated in 11 objects (23.4%), and adjacent vessel depiction was worsened in eight objects (17.0%). In addition, new O-MAR-related streak artifacts were observed in 32 objects (68.1%). New streak artifacts were more prevalent in cases with overlapping metallic implants on the same axial plane than in those without (P = 0.018). Qualitative assessment revealed that the overall image quality was not significantly improved in O-MAR images. CONCLUSION In conclusion, the use of the O-MAR in patients with metallic implants significantly reduces image noise. However, the degree of the streak artifacts and surrounding vessel depiction were not significantly improved on O-MAR images.
Collapse
Affiliation(s)
- Leonard Sunwoo
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Sun-Won Park
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
- Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Jung Hyo Rhim
- Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Yeonah Kang
- Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Young Seob Chung
- Department of Neurosurgery, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Young-Je Son
- Department of Neurosurgery, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Soo Chin Kim
- Department of Radiology, Seoul National University Hospital, Healthcare System Gangnam Center, Seoul, Korea
| |
Collapse
|
15
|
Hajdu SD, Daniel RT, Meuli RA, Zerlauth JB, Dunet V. Impact of model-based iterative reconstruction (MBIR) on image quality in cerebral CT angiography before and after intracranial aneurysm treatment. Eur J Radiol 2018; 102:109-114. [PMID: 29685523 DOI: 10.1016/j.ejrad.2018.03.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Revised: 03/04/2018] [Accepted: 03/05/2018] [Indexed: 12/25/2022]
Abstract
PURPOSE To subjectively and objectively assess the impact of model-based iterative reconstruction(MBIR) on image quality in cerebral computed tomography angiography compared to adaptive statistical iterative reconstruction (ASIR). METHODS 107 patients (mean age: 58 ± 14 years) were included prior to (n = 38) and after (n = 69) intracranial aneurysm treatment. Images were acquired using a routine protocol and reconstructed with MBIR and ASIR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios in the internal carotid and middle cerebral arteries were compared between MBIR and ASIR using the Wilcoxon signed-rank test. Additionally, two neuroradiologists subjectively assessed noise, artefacts, vessel sharpness and overall quality using a semi-quantitative assessment scale. RESULTS Objective assessment revealed that MBIR reduced noise (p < 0.0001) and additionally improved SNR (p < 0.0001) and CNR (p < 0.0001) compared to ASIR in untreated and treated patients. Subjective assessment revealed that in untreated patients, MBIR improved noise reduction, artefacts, vessel sharpness and overall quality relative to ASIR (p < 0.0001). In the treated groups, noise and vessel sharpness were improved (p < 0.0001) with no change in artefacts on images reconstructed with MBIR compared to ASIR. CONCLUSION MBIR significantly improves noise, SNR, CNR and vessel sharpness in untreated and treated patients with intracranial aneurysms. MBIR does not reduce artefacts generated by metallic devices following intracranial aneurysm treatment.
Collapse
Affiliation(s)
- Steven David Hajdu
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland.
| | - Roy Thomas Daniel
- Department of Neurosurgery, Lausanne University Hospital, Lausanne, Switzerland
| | - Reto Antoine Meuli
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Jean-Baptiste Zerlauth
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Vincent Dunet
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| |
Collapse
|
16
|
Winklhofer S, Hinzpeter R, Stocker D, Baltsavias G, Michels L, Burkhardt JK, Regli L, Valavanis A, Alkadhi H. Combining monoenergetic extrapolations from dual-energy CT with iterative reconstructions: reduction of coil and clip artifacts from intracranial aneurysm therapy. Neuroradiology 2018; 60:281-291. [DOI: 10.1007/s00234-018-1981-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Accepted: 01/10/2018] [Indexed: 10/18/2022]
|
17
|
Dunet V, Bernasconi M, Hajdu SD, Meuli RA, Daniel RT, Zerlauth JB. Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping. Neuroradiology 2017; 59:845-852. [DOI: 10.1007/s00234-017-1871-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 06/19/2017] [Indexed: 10/19/2022]
|
18
|
Lin A, Rawal S, Agid R, Mandell DM. Cerebrovascular Imaging: Which Test is Best? Neurosurgery 2017; 83:5-18. [DOI: 10.1093/neuros/nyx325] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Accepted: 05/12/2017] [Indexed: 11/12/2022] Open
Abstract
Abstract
Optimal diagnosis and characterization of cerebrovascular disease requires selection of the appropriate imaging exam for each clinical situation. In this review, we focus on intracranial arterial disease and discuss the techniques in current clinical use for imaging the blood vessel lumen and blood vessel wall, and for mapping cerebral hemodynamic impairment at the tissue level. We then discuss specific strategies for imaging intracranial aneurysms, arteriovenous malformations, dural arterial venous fistulas, and arterial steno-occlusive disease.
Collapse
Affiliation(s)
- Amy Lin
- Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital and the University of Toronto, Toronto, Ontario, Canada
| | - Sapna Rawal
- Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital and the University of Toronto, Toronto, Ontario, Canada
| | - Ronit Agid
- Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital and the University of Toronto, Toronto, Ontario, Canada
| | - Daniel M Mandell
- Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital and the University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
19
|
Abdulazim A, Rubbert C, Reichelt D, Mathys C, Turowski B, Steiger HJ, Hänggi D, Etminan N. Dual- versus Single-Energy CT-Angiography Imaging for Patients Undergoing Intracranial Aneurysm Repair. Cerebrovasc Dis 2017; 43:272-282. [PMID: 28319953 DOI: 10.1159/000464356] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2016] [Accepted: 02/20/2017] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The invasiveness and risk of thromboembolic complications of catheter angiography underline the need for alternative imaging modalities in patients following intracranial aneurysm (IA) repair. However, the overall image quality of existing noninvasive imaging modalities, such as single-energy CT angiography (SE-CTA), compromises its value in this respect. OBJECTIVE We prospectively investigated the value of a novel dual-energy CTA (DE-CTA) scanner and algorithm for assessing the degree of occlusion and parent vessel patency in patients following IA repair. METHODS A prospective cohort of 17 patients underwent DE-CTA imaging following surgical or endovascular IA repair. This dataset was matched with an identical historical cohort of 17 patients, who underwent IA repair and SE-CTA imaging. Beam-hardening artifacts, as a measure for objective imaging quality were analyzed based on the volume of a prolate ellipsoid, whereas subjective imaging quality at the IA site and corresponding parent vessels was rated by 2 independent neuroradiologists on a scale from 4 (excellent, no artifacts) to 1 (poor, severe artifacts). RESULTS Objective DE-CTA image quality was markedly higher, compared to SE-CTA in patients undergoing surgical (0.77 ± 0.23 vs. 10.91 ± 1.88 mL, respectively; p < 0.001) or endovascular (32.36 ± 10.62 vs. 107.63 ± 24.51 mL, respectively; p = 0.026) IA repair. Subjective image quality for DE-CTA was significantly improved compared to SE-CTA in the surgical group but not in the endovascular group. The calculated dose values for DE-CTA in our study remain markedly below the legally required radiation dose limits. CONCLUSION The imaging quality of DE-CTA, especially for patients undergoing surgical IA repair, is distinctly superior, compared to SE-CTA imaging. Therefore, DE-CTA may serve as a noninvasive alternative for assessing the IA occlusion rate and parent vessel patency.
Collapse
Affiliation(s)
- Amr Abdulazim
- Department of Neurosurgery, University Hospital Mannheim, University of Heidelberg, Mannheim, Germany
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Vali A, Abla AA, Lawton MT, Saloner D, Rayz VL. Computational Fluid Dynamics modeling of contrast transport in basilar aneurysms following flow-altering surgeries. J Biomech 2016; 50:195-201. [PMID: 27890537 DOI: 10.1016/j.jbiomech.2016.11.028] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Accepted: 11/05/2016] [Indexed: 10/20/2022]
Abstract
In vivo measurement of blood velocity fields and flow descriptors remains challenging due to image artifacts and limited resolution of current imaging methods; however, in vivo imaging data can be used to inform and validate patient-specific computational fluid dynamics (CFD) models. Image-based CFD can be particularly useful for planning surgical interventions in complicated cases such as fusiform aneurysms of the basilar artery, where it is crucial to alter pathological hemodynamics while preserving flow to the distal vasculature. In this study, patient-specific CFD modeling was conducted for two basilar aneurysm patients considered for surgical treatment. In addition to velocity fields, transport of contrast agent was simulated for the preoperative and postoperative conditions using two approaches. The transport of a virtual contrast passively following the flow streamlines was simulated to predict post-surgical flow regions prone to thrombus deposition. In addition, the transport of a mixture of blood with an iodine-based contrast agent was modeled to compare and verify the CFD results with X-ray angiograms. The CFD-predicted patterns of contrast flow were qualitatively compared to in vivo X-ray angiograms acquired before and after the intervention. The results suggest that the mixture modeling approach, accounting for the flow rates and properties of the contrast injection, is in better agreement with the X-ray angiography data. The virtual contrast modeling assessed the residence time based on flow patterns unaffected by the injection procedure, which makes the virtual contrast modeling approach better suited for prediction of thrombus deposition, which is not limited to the peri-procedural state.
Collapse
Affiliation(s)
- Alireza Vali
- Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Adib A Abla
- Department of Neurosurgery, University of Arkansas for Medical Science, AR, USA
| | - Michael T Lawton
- Department of Neurological Surgery, University of California, San Francisco, CA, USA
| | - David Saloner
- Department of Radiology and Biomedical Imaging University of California, San Francisco, CA, USA
| | - Vitaliy L Rayz
- Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, USA; Department of Mechanical Engineering, University of Wisconsin, Milwaukee, WI, USA.
| |
Collapse
|
21
|
Hage ZA, Alaraj A, Arnone GD, Charbel FT. Novel imaging approaches to cerebrovascular disease. Transl Res 2016; 175:54-75. [PMID: 27094991 DOI: 10.1016/j.trsl.2016.03.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 03/22/2016] [Accepted: 03/23/2016] [Indexed: 11/19/2022]
Abstract
Imaging techniques available to the physician treating neurovascular disease have substantially grown over the past several decades. New techniques as well as advances in imaging modalities continuously develop and provide an extensive array of modalities to diagnose, characterize, and understand neurovascular pathology. Modern noninvasive neurovascular imaging is generally based on computed tomography (CT), magnetic resonance (MR) imaging, or nuclear imaging and includes CT angiography, CT perfusion, xenon-enhanced CT, single-photon emission CT, positron emission tomography, magnetic resonance angiography, MR perfusion, functional magnetic resonance imaging with global and regional blood oxygen level dependent imaging, and magnetic resonance angiography with the use of the noninvasive optional vessel analysis software (River Forest, Ill). In addition to a brief overview of the technique, this review article discusses the clinical indications, advantages, and disadvantages of each of those modalities.
Collapse
Affiliation(s)
- Ziad A Hage
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, Ill, USA
| | - Ali Alaraj
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, Ill, USA
| | - Gregory D Arnone
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, Ill, USA
| | - Fady T Charbel
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, Ill, USA.
| |
Collapse
|
22
|
Janiga G, Daróczy L, Berg P, Thévenin D, Skalej M, Beuing O. An automatic CFD-based flow diverter optimization principle for patient-specific intracranial aneurysms. J Biomech 2015; 48:3846-52. [PMID: 26472308 DOI: 10.1016/j.jbiomech.2015.09.039] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2015] [Revised: 09/18/2015] [Accepted: 09/24/2015] [Indexed: 11/26/2022]
Abstract
The optimal treatment of intracranial aneurysms using flow diverting devices is a fundamental issue for neuroradiologists as well as neurosurgeons. Due to highly irregular manifold aneurysm shapes and locations, the choice of the stent and the patient-specific deployment strategy can be a very difficult decision. To support the therapy planning, a new method is introduced that combines a three-dimensional CFD-based optimization with a realistic deployment of a virtual flow diverting stent for a given aneurysm. To demonstrate the feasibility of this method, it was applied to a patient-specific intracranial giant aneurysm that was successfully treated using a commercial flow diverter. Eight treatment scenarios with different local compressions were considered in a fully automated simulation loop. The impact on the corresponding blood flow behavior was evaluated qualitatively as well as quantitatively, and the optimal configuration for this specific case was identified. The virtual deployment of an uncompressed flow diverter reduced the inflow into the aneurysm by 24.4% compared to the untreated case. Depending on the positioning of the local stent compression below the ostium, blood flow reduction could vary between 27.3% and 33.4%. Therefore, a broad range of potential treatment outcomes was identified, illustrating the variability of a given flow diverter deployment in general. This method represents a proof of concept to automatically identify the optimal treatment for a patient in a virtual study under certain assumptions. Hence, it contributes to the improvement of virtual stenting for intracranial aneurysms and can support physicians during therapy planning in the future.
Collapse
Affiliation(s)
- Gábor Janiga
- Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg "Otto von Guericke" Universitätsplatz, 2 D-39106 Magdeburg, Germany.
| | - László Daróczy
- Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg "Otto von Guericke" Universitätsplatz, 2 D-39106 Magdeburg, Germany
| | - Philipp Berg
- Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg "Otto von Guericke" Universitätsplatz, 2 D-39106 Magdeburg, Germany
| | - Dominique Thévenin
- Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg "Otto von Guericke" Universitätsplatz, 2 D-39106 Magdeburg, Germany
| | - Martin Skalej
- Institute for Neuroradiology, University of Magdeburg "Otto von Guericke", Germany
| | - Oliver Beuing
- Institute for Neuroradiology, University of Magdeburg "Otto von Guericke", Germany
| |
Collapse
|
23
|
Thompson BG, Brown RD, Amin-Hanjani S, Broderick JP, Cockroft KM, Connolly ES, Duckwiler GR, Harris CC, Howard VJ, Johnston SCC, Meyers PM, Molyneux A, Ogilvy CS, Ringer AJ, Torner J. Guidelines for the Management of Patients With Unruptured Intracranial Aneurysms: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association. Stroke 2015; 46:2368-400. [PMID: 26089327 DOI: 10.1161/str.0000000000000070] [Citation(s) in RCA: 599] [Impact Index Per Article: 66.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
PURPOSE The aim of this updated statement is to provide comprehensive and evidence-based recommendations for management of patients with unruptured intracranial aneurysms. METHODS Writing group members used systematic literature reviews from January 1977 up to June 2014. They also reviewed contemporary published evidence-based guidelines, personal files, and published expert opinion to summarize existing evidence, indicate gaps in current knowledge, and when appropriate, formulated recommendations using standard American Heart Association criteria. The guideline underwent extensive peer review, including review by the Stroke Council Leadership and Stroke Scientific Statement Oversight Committees, before consideration and approval by the American Heart Association Science Advisory and Coordinating Committee. RESULTS Evidence-based guidelines are presented for the care of patients presenting with unruptured intracranial aneurysms. The guidelines address presentation, natural history, epidemiology, risk factors, screening, diagnosis, imaging and outcomes from surgical and endovascular treatment.
Collapse
|
24
|
Budai C, Cirillo L, Patruno F, Dall'olio M, Princiotta C, Leonardi M. Flat panel angiography images in the post-operative follow-up of surgically clipped intracranial aneurysms. Neuroradiol J 2014; 27:203-6. [PMID: 24750710 DOI: 10.15274/nrj-2014-10022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Accepted: 02/01/2014] [Indexed: 11/12/2022] Open
Abstract
Cerebral aneurysms must be monitored for varying periods after surgical and/or endovascular treatment and the duration of follow-up will depend on the type of therapy and the immediate post-operative outcome. Surgical clipping for intracranial aneurysms is a valid treatment but the metal clips generate artefacts so that follow-up monitoring still relies on catheter angiography. This study reports our preliminary experience with volumetric angiography using a Philips Allura Xper FD biplane system in the post-operative monitoring of aneurysm residues or major vascular changes following the surgical clipping of intracranial aneurysms. Volumetric angiography yields not only volume-rendered (VR) images, but a volume CT can also be reconstructed at high spatial and contrast resolution from a single acquisition, significantly enhancing the technique's diagnostic power. Between August 2012 and April 2013, we studied 19 patients with a total of 26 aneurysms treated by surgical clipping alone or in combination with endovascular treatment. All patients underwent standard post-operative angiographic follow-up including a rotational volumetric acquisition. Follow-up monitoring disclosed eight aneurysm residues whose assessment was optimal after surgical clipping both in patients with one metal clip and in those with two or more clips. In addition, small residues (1.3 mm) could be monitored together with any change in the calibre or course of vessels located adjacent to the clips. In conclusion, flat panel volume CT is much more reliable than the old 3D acquisitions that yielded only VR images. This is particularly true in patients with small aneurysm residues or lesions with multiple metal clips.
Collapse
Affiliation(s)
- Caterina Budai
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy -
| | - Luigi Cirillo
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy - Department of Experimental, Diagnostic and Specialty Medicine (DIMES), University of Bologna; Bologna, Italy
| | - Francesco Patruno
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy
| | - Massimo Dall'olio
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy
| | - Ciro Princiotta
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy
| | - Marco Leonardi
- Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna; Bologna, Italy - Department of Experimental, Diagnostic and Specialty Medicine (DIMES), University of Bologna; Bologna, Italy
| |
Collapse
|
25
|
Assessment of long-term results of intracranial aneurysm clipping by means of computed tomography angiography. Neurol Neurochir Pol 2013; 47:18-26. [PMID: 23487290 DOI: 10.5114/ninp.2012.31549] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND AND PURPOSE The aim of this retrospective study was to assess the effectiveness of aneurysm clipping by computed tomography angiography (CTA) in a long-term follow-up. MATERIAL AND METHODS The CTA examination was performed in 119 patients who had 143 aneurysms clipped. The examinations were performed 3 to 11 years (mean 6 years) after clipping using a GE Lightspeed PRO16 scanner. RESULTS In all cases but one, good quality CTA images, suitable for evaluation of the arteries around the clip site, were obtained. Complete aneurysm closure without neck remnant or regrowth was confirmed in 137 (96%) aneurysms. In 4 (3%) cases, neck remnants were detected (2 on the anterior communicating artery [AComA] and 2 on the middle cerebral artery [MCA]). A total clip slippage from the aneurysm dome was revealed in 1 case. One case of aneurysm re-rupture was noted, 11 years after clipping. The rebleeding was caused by AComA aneurysm regrowth. Among these 6 patients with unsatisfactory clipping, 2 required further treatment and 4 remain under observation. Nineteen 'de novo' aneurysms in other locations were found in 14 (12%) patients. Summing up all of the pathological findings in the study group, there were 18 (15%) patients who needed further management including close surveillance or re-treatment. CONCLUSIONS Computed tomography angiography is a simple and reliable method of aneurysm clipping evaluation. The long- term follow-up CTA confirmed the permanent and complete obliteration of 96% of the aneurysms. The rate of unsatisfactory aneurysm closure was 4%, but only 1.4% needed re-treatment during a mean follow-up of 6 years. The annual risk of aneurysm re-rupture was 0.1%.
Collapse
|
26
|
Pereira VM, Bijlenga P, Marcos A, Schaller K, Lovblad KO. Diagnostic approach to cerebral aneurysms. Eur J Radiol 2012; 82:1623-32. [PMID: 23158462 DOI: 10.1016/j.ejrad.2012.10.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2012] [Accepted: 10/25/2012] [Indexed: 10/27/2022]
Abstract
Cerebral aneurysms are an important cause of morbidity and mortality due to their causal effect in non-traumatic subarachnoid hemorrhage. Neurosurgical progress in the 20th century helped to improve patient outcomes greatly. In recent years, techniques such as intravascular treatment by coiling and/or stenting have found an additional place in the management of the disease. With the development of less and less invasive surgical and endovascular techniques, there has also been a continuous development in imaging techniques that have led to our current situation where we dispose of CT and MR techniques that can help improve treatment planning greatly. CT is able to detect and together with its adjunct techniques CT angiography and CT perfusion, it can allow us to provide the physicians in charge with a detailed image of the aneurysm, the feeding vessels as well as the status of blood flow to the brain. Angiography has evolved by becoming the standard tool for guidance during decision making for whatever therapy is being envisioned be it endovascular procedures and or surgery and has even progressed more recently due to the development of so-called flat panel technology that now allows to acquire CT-like images during and directly after an intervention. Thus nowadays, the diagnostic and interventional techniques and procedures have become so much entwined as to be considered a whole.
Collapse
Affiliation(s)
- Vitor Mendes Pereira
- Division of Diagnostic and Interventional Neuroradiology, Geneva University Hospitals, Switzerland
| | | | | | | | | |
Collapse
|
27
|
Murai Y, Adachi K, Takagi R, Koketsu K, Matano F, Teramoto A. Intraoperative Matas test using microscope-integrated intraoperative indocyanine green videoangiography with temporary unilateral occlusion of the A1 segment of the anterior cerebral artery. World Neurosurg 2012; 76:477.e7-477.e10. [PMID: 22152581 DOI: 10.1016/j.wneu.2011.03.044] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2010] [Accepted: 03/30/2011] [Indexed: 11/28/2022]
Abstract
OBJECTIVE The aim of the present study was to assess a new technique of surgical microscope-based indocyanine green (ICG) videoangiography (VAG) to confirm the patency of the anterior communicating artery (AcomA) after clipping AcomA aneurysms. METHODS Aneurysmal clipping of five cases of unruptured, broad-neck AcomA aneurysm was performed using the Carl Zeiss Surgical Microscope OPMI Pentero INFRARED 800. RESULTS In all five patients, after clipping AcomA aneurysms, the patency of AcomA was confirmed using ICGVAG findings and temporary unilateral occlusion of the A1 segment of the anterior cerebral artery using temporary clips. Images were excellent and enabled a real-time surgical assessment because the structures of interest, including vessels, perforating arteries, or residual aneurysm neck, were visible to the surgeon's eye under the microscope in all five patients. CONCLUSIONS ICGVAG and temporary unilateral occlusion with clips provides a simple, reliable, real-time, and rapid intraoperative assessment of the patency of AcomA. This technique may help to improve the quality of neurosurgical procedures.
Collapse
Affiliation(s)
- Yasuo Murai
- Department of Neurosurgery, Nippon Medical School, Tokyo, Japan.
| | | | | | | | | | | |
Collapse
|
28
|
Killer M, McCoy MR, Vestal MC, Weitgasser L, Cruise GM. Use of CT angiography in comparison with other imaging techniques for the determination of embolus and remnant size in experimental aneurysms embolized with hydrogel filaments. AJNR Am J Neuroradiol 2011; 32:923-8. [PMID: 21511861 DOI: 10.3174/ajnr.a2554] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Beam-hardening artifacts in CTA can be greatly reduced by using metal-free coils for aneurysm embolization. We compared the embolic masses and remnants of experimental rabbit aneurysms coiled with hydrogel filaments by using DSA, CTA and histology. MATERIALS AND METHODS Embolization of 12 rabbit bifurcation aneurysms was performed with detachable hydrogel filaments. Six aneurysms were embolized as completely as possible, and 6 aneurysms were embolized incompletely to intentionally leave remnants. Three aneurysms in each group underwent follow-up at 4 and 13 weeks. DSA, MRA, and CTA were performed immediately before sacrifice. The harvested aneurysms were evaluated histologically. For each imaging technique, the areas of the embolic mass and remnant were determined by using image analysis. Results were compared by using paired t tests. RESULTS CTAs were suitable for quantification of the embolus and remnant areas because only small streaking artifacts were evident. The areas of the embolus were larger on CTA compared with DSA and histologic sections. The areas of the remnant were larger on CTA and MRA compared with DSA and histologic sections. Like DSA and MRA, CTA was suitable for determining whether aneurysm retreatment was necessary, provided that loops of hydrogel filaments were not present in the parent artery. CONCLUSIONS We demonstrated that CTA is a technique with potential for surveillance of aneurysms treated with hydrogel filaments. Additional work is required to determine the accuracy of the technique compared with currently accepted imaging modalities of DSA and MRA.
Collapse
Affiliation(s)
- M Killer
- Neuroscience Institute/Department of Neurology, Paracelsus Medical University, Christian Doppler Clinic, Salzburg, Austria.
| | | | | | | | | |
Collapse
|
29
|
Jiang L, He ZH, Zhang XD, Lin B, Yin XH, Sun XC. Value of noninvasive imaging in follow-up of intracranial aneurysm. ACTA NEUROCHIRURGICA. SUPPLEMENT 2011; 110:227-232. [PMID: 21125476 DOI: 10.1007/978-3-7091-0356-2_41] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Follow-up is necessary for treated and untreated aneurysms. The purpose of this study is to assess the results of treated aneurysms, the development of untreated aneurysms and the incidence of new aneurysms through short-term follow-up with noninvasive imaging, including CTA and MRA. More-than-once follow-up imaging with either CTA or MRA was performed in 73 patients, 65 of them suffering SAH. CTA was performed in 46 patients with clipped aneurysms, 9 patients with coiled aneurysms and 8 cases with untreated aneurysms. MRA was performed in ten patients with coiled aneurysms. CTA follow-up demonstrated that in 48 clipped aneurysms, 47 aneurysms completely disappeared; one aneurysm with neck remnant and one new aneurysm was found. No recurrence was found after microsurgical clipping. CTA follow-up provided limited information for ten coiled aneurysms because of poor quality images due to artifacts from coil. MRA follow-up of 12 coiled aneurysms showed there were no recanalization, recurrence or new aneurysm. In 20 untreated aneurysms, 19 stayed unchanged, and one aneurysm automatically disappeared. The newest generation of CTA and MRA can be used for following-up of intracranial aneurysms, and is more readily accepted by Chinese patients because of convenience, non-invasiveness and low price.
Collapse
Affiliation(s)
- Li Jiang
- Department of Neurosurgery, First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, P.R. China
| | | | | | | | | | | |
Collapse
|
30
|
Khan R, Wallace RC, Fiorella DJ. Magnetic resonance angiographic imaging follow-up of treated intracranial aneurysms. Top Magn Reson Imaging 2008; 19:231-239. [PMID: 19512855 DOI: 10.1097/rmr.0b013e3181a8df00] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Conventional catheter-based angiography, magnetic resonance imaging/angiography, and computed tomographic angiography are all techniques routinely practiced for the diagnosis of aneurysms. With regard to the evaluation of treated aneurysms, each of these imaging modalities has inherent advantages and disadvantages. This review was aimed to provide a better understanding of the optimal application and interpretation of the available imaging modalities for the assessment of treated cerebral aneurysms.
Collapse
Affiliation(s)
- Rihan Khan
- Department of Neuroradiology, Barrow Neurological Institute, St Joseph's Hospital and Medical Center, Phoenix, AZ, USA.
| | | | | |
Collapse
|