1
|
Exploring the Landscape of Intracranial Aneurysms in South America: A Comprehensive Narrative Review Intracranial Aneurysms in South America. World Neurosurg 2024; 185:3-25. [PMID: 38286319 DOI: 10.1016/j.wneu.2024.01.108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 01/19/2024] [Indexed: 01/31/2024]
Abstract
Exploring the landscape of intracranial aneurysms in South America unravels a complex interplay of epidemiological factors, clinical manifestations, and therapeutic challenges. The study methodically conducts a comprehensive literature review spanning the years 2003 to 2023, focusing on English-language articles obtained from diverse databases to elucidate the multifaceted nature of intracranial aneurysms in the region. Results and discussions categorize outcomes into positive domains, emphasizing successful treatments, favorable recoveries, and high survival rates, while also shedding light on negative aspects such as residual aneurysms and complications. The research illuminates significant gaps in pathological typing of intracranial aneurysms and exposes challenges in healthcare accessibility, notably the disparities in neurosurgical resources. Management challenges, including constrained infrastructure access, a neurosurgeon shortage, and gender disparities, are underscored. Transitioning to future prospects, the study advocates for strategic interventions, proposing expanded neurosurgical training, multidisciplinary approaches, improved funding, enhanced access to care, and fostering international collaborations. The study concludes by emphasizing the pivotal role of collaborative efforts, intensified training programs, and global partnerships in propelling intracranial aneurysm management forward in South America, ultimately contributing to enhanced patient outcomes across the region.
Collapse
|
2
|
Comparison of pipeline embolization device and tubridge flow diverter for posterior circulation aneurysms: A multicentre propensity score matched study. Heliyon 2024; 10:e27410. [PMID: 38510002 PMCID: PMC10950592 DOI: 10.1016/j.heliyon.2024.e27410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 02/26/2024] [Accepted: 02/28/2024] [Indexed: 03/22/2024] Open
Abstract
Rationale and objectives The off-label use of flow diverters (FDs) has broadened to include treating aneurysms in posterior circulation (PC). A novel flow diverter, the Tubridge flow diverter (TFD), has been created in China specifically for treating PC aneurysms. However, studies comparing between pipeline embolization device (PED) and TFD are rare. Thus, our study aimed to explore the effectiveness of PED and TFD in the treatment of PC aneurysms using a propensity score matched cohort design. Methods Retrospective data collection was conducted on patients who underwent treatment with either PED or TFD over the period from 2015 through 2020. Propensity score matching (PSM) was employed to calibrate for patient age; history of ischemic stroke; aneurysm size; morphology; location and neck; number of FDs; parent vessel diameter; and the employment of assisted coiling and balloon techniques. Data on previously ruptured aneurysms was not included in the analysis. A comparison was conducted between the two devices to assess perioperative complications, aneurysm occlusion rates, and functional outcomes. Results A total of 252 PC aneurysms were treated in 248 patients. Clinical and imaging follow-ups were lost in 26 and 47 patients, respectively. Major perioperative complications occurred in 7.5% of the cases, with favorable clinical outcomes in 91.0% and complete occlusion in 79.1%. Eighty-two (32.5%) aneurysms were treated with TFD, while 170 (67.5%) aneurysms were treated with PED. PSM was used to account for these significant variations, producing 82 matched pairs of unruptured aneurysms treated with PED or TFD. In terms of functional and angiographic outcomes, no significant differences were found between PED and TFD (functional outcome, p = 0.594 and angiographic outcome, p = 0.415). However, more perioperative major complications were found in patients treated with TFD (p = 0.005) compared with those receiving PED. Conclusion The comparative study of PED and TFD in the treatment of PC aneurysms resulted in positive clinical results and sustained occlusion rates, with acceptable perioperative complications. However, higher quality studies are needed to enhance our understanding of the use of FDs for treating of PC aneurysms.
Collapse
|
3
|
Flow diversion for basilar quadrifurcation aneurysms. J Neurointerv Surg 2024; 16:372-378. [PMID: 37253595 DOI: 10.1136/jnis-2022-019238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 05/01/2023] [Indexed: 06/01/2023]
Abstract
BACKGROUND Flow-diverting devices (FDDs), such as the Pipeline Embolization Device, have been gaining traction for treating challenging posterior circulation aneurysms. Few previous studies have focused on using FDDs to treat aneurysms of the basilar quadrifurcation. METHODS We retrospectively reviewed the use of FDDs to treat patients with basilar quadrifurcation aneurysms. Patients were assessed for aneurysm type, previous aneurysm treatment, technical success, periprocedural complications, and long-term aneurysm occlusion. RESULTS 34 patients were assessed; aneurysms of the basilar apex (n=23) or superior cerebellar artery (SCA) (n=7), or both (n=1), and posterior cerebral artery (PCA) (n=3). The mean (SD) largest aneurysm dimension was 8.7 (6.1) mm (range 1.9-30.8 mm). 14 aneurysms were previously surgically clipped or endovascularly coiled. All aneurysms had a saccular morphology. Complete or near-complete occlusion was achieved in 30 of 34 patients (88%) at final angiographic follow-up, a mean (SD) of 6.6 (5.4) months (range 0-19 months) postoperatively. No patient experienced postoperative symptomatic occlusions of the SCA or PCA; 4 patients developed asymptomatic posterior communicating artery occlusions; 28 patients (82%) experienced no complications; whereas 3 (9%) experienced major complications and 3 (9%) experienced minor complications; and 1 patient died as a result of subarachnoid hemorrhage. CONCLUSION Flow diversion may be a safe and effective option to treat basilar quadrifurcation aneurysms. Previously treated basilar quadrifurcation aneurysms with recurrence or residual lesion may benefit from additional treatment with an FDD. Further prospective studies should be directed toward validating these findings.
Collapse
|
4
|
A vertebrobasilar junction aneurysm successfully treated with a combination of surgical clipping and flow diverter placement based on the results of computational fluid dynamics analysis: illustrative case. JOURNAL OF NEUROSURGERY. CASE LESSONS 2024; 7:CASE23736. [PMID: 38437674 PMCID: PMC10916842 DOI: 10.3171/case23736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 01/29/2024] [Indexed: 03/06/2024]
Abstract
BACKGROUND The treatment of vertebrobasilar junction (VBJ) aneurysms is challenging. Although flow diverters (FDs) are a possible treatment option, geometrical conditions hinder intervention. VBJ aneurysms possess dual inflow vessels from the bilateral vertebral arteries (VAs), one of which is ideally occluded prior to FD treatment. However, it remains unclear which VA should be occluded. OBSERVATIONS A 75-year-old male with a growing VBJ complex aneurysm exhibiting invagination toward the brainstem and causing perifocal edema required intervention. Preoperative computational fluid dynamics (CFD) analysis demonstrated that left VA occlusion would result in more stagnant flow and less impingement of flow than right VA occlusion. According to the simulated strategy, surgical clipping of the left VA just proximal to the aneurysm was performed, followed by FD placement from the basilar artery trunk to the right VA. The patient demonstrated tolerance of the VA occlusion, and follow-up computed tomography angiography at 18 months after FD treatment confirmed the disappearance of the aneurysm. LESSONS Preoperative flow dynamics simulations using CFD analysis can reveal an optimal treatment strategy involving a hybrid surgery that combines FD placement and direct surgical occlusion for a VBJ complex aneurysm.
Collapse
|
5
|
Outcomes Associated With Intracranial Aneurysm Treatments Reported as Safe, Effective, or Durable: A Systematic Review and Meta-Analysis. JAMA Netw Open 2023; 6:e2331798. [PMID: 37656458 PMCID: PMC10474558 DOI: 10.1001/jamanetworkopen.2023.31798] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 07/25/2023] [Indexed: 09/02/2023] Open
Abstract
Importance Testing new medical devices or procedures in terms of safety, effectiveness, and durability should follow the strictest methodological rigor before implementation. Objectives To review and analyze studies investigating devices and procedures used in intracranial aneurysm (IA) treatment for methods and completeness of reporting and to compare the results of studies with positive, uncertain, and negative conclusions. Data Sources Embase, MEDLINE, Web of Science, and The Cochrane Central Register of Clinical Trials were searched for studies on IA treatment published between January 1, 1995, and the October 1, 2022. Grey literature was retrieved from Google Scholar. Study Selection All studies making any kind of claims of safety, effectiveness, or durability in the field of IA treatment were included. Data Extraction and Synthesis Using a predefined data dictionary and analysis plan, variables ranging from patient and aneurysm characteristics to the results of treatment were extracted, as were details pertaining to study methods and completeness of reporting. Extraction was performed by 10 independent reviewers. A blinded academic neuro-linguist without involvement in IA research evaluated the conclusion of each study as either positive, uncertain, or negative. The study followed Preferring Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Main Outcomes and Measures The incidence of domain-specific outcomes between studies with positive, uncertain, or negative conclusions regarding safety, effectiveness, or durability were compared. The number of studies that provided a definition of safety, effectiveness, or durability and the incidence of incomplete reporting of domain-specific outcomes were evaluated. Results Overall, 12 954 studies were screened, and 1356 studies were included, comprising a total of 410 993 treated patients. There was no difference in the proportion of patients with poor outcome or in-hospital mortality between studies claiming a technique was safe, uncertain, or not safe. Similarly, there was no difference in the proportion of IAs completely occluded at last follow-up between studies claiming a technique was effective, uncertain, or noneffective. Less than 2% of studies provided any definition of safety, effectiveness, or durability, and only 1 of the 1356 studies provided a threshold under which the technique would be considered unsafe. Incomplete reporting was found in 546 reports (40%). Conclusions and Relevance In this systematic review and meta-analysis of IA treatment literature, studies claiming safety, effectiveness, or durability of IA treatment had methodological flaws and incomplete reporting of relevant outcomes supporting these claims.
Collapse
|
6
|
Surpass embolization of intracranial aneurysms: Perspective from a 2-year longitudinal follow-up study across high volume comprehensive stroke centers. Interv Neuroradiol 2023:15910199231188760. [PMID: 37464776 DOI: 10.1177/15910199231188760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/20/2023] Open
Abstract
BACKGROUND Surpass Streamline (SS; Stryker©) is an over-the-wire first-generation flow diverter (FD). There is a scarcity of data on real-world outcomes and complications of this FD. METHODS A retrospective review of consecutive cases between January 2019 and July 2021 at two high-volume comprehensive stroke centers, involving SS was conducted. RESULTS Fifty-five patients harbored 69 treated aneurysms, of which 96% were in the internal carotid petrous to terminus segments and 88% were <10 mm in size, and 12% measuring 10-24 mm. Raymond Roy Grade 1 occlusion was noted in 55 aneurysms (79.7%) at 1 year. Median follow-up duration was 26 months (mean = 26.06). Major complications were seen in eight patients (14.5%; 95% CI 6.5-26.7) and mortality attributable to SS stenting complications occurred in two (4.3%) patients. Four (7.2%) had ophthalmologic thromboembolic complications and two had (3.6%) ischemic complications. Procedural complications occurred in 10 patients (18.18%; 95% CI 9.1-30.9). Technical complications during procedure (n = 3, 5.3%) were: "confirmed" distal middle cerebral artery (MCA) guidewire perforation; "suspected" distal MCA guidewire perforation causing post-procedural subarachnoid hemorrhage and internal carotid artery dissection causing ischemic stroke. Seizures were seen in 5 (9.09%) and carotid-cavernous fistula in 1 (1.8%). Multivariate regression analysis showed technical challenges significantly predicted occurrence of major complications (p = 0.001; R2 = 0.39, F(13,43) = 2.15, p = 0.029). Univariate analysis showed technical challenges significantly predicted ophthalmological complications (R2 = 0.06, F(1,55) = 4.04, p = 0.049) and major complications (R2 = 0.21, F(1,55) = 15.11, p = 0.0002). CONCLUSION Large-scale future registry should focus on national data regarding SS safety, technical challenges, and procedural complications. We present one of the longest follow-ups for SS in literature.
Collapse
|
7
|
Utility of flow diverters in treatment of acutely ruptured uncoilable aneurysms of the posterior circulation of the brain. Jpn J Radiol 2023:10.1007/s11604-023-01409-y. [PMID: 36920731 DOI: 10.1007/s11604-023-01409-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 02/27/2023] [Indexed: 03/16/2023]
Abstract
PURPOSE Aim of this study is to evaluate safety and efficacy of flow diverters (FDs) in treatment of acutely ruptured posterior circulation aneurysms MATERIALS AND METHODS: Databases of three participating institutions were retrospectively scanned for patients in whom FD placement was attempted for treatment of acutely ruptured vertebrobasilar aneurysms. An interval of 14 days or fewer between the latest ictus and treatment was used as inclusion criterion. Patients with dolichoectasia of vertebrobasilar arteries were excluded. If necessary, adjunctive techniques including coiling or stenting were utilized. Clinical outcomes were graded using mWFNS (modified World Federation of Neurosurgical Societies Scale) and mRS (modified Rankin Scale). Aneurysmal occlusion was defined as Raymond-Roy Class 1. Spearman's (ρ) test was used to assess the correlation between variables. Univariate and multivariate logistic regression were used to assess outcomes. RESULTS 31 patients (25 women, mean age: 52.7 ± 15.2) harboring 32 aneurysms (16 non-saccular, mean size: 11.4 ± 7 mm) were included. Mean number of FDs used was 1.22 ± 0.42. In six cases, adjunctive coiling and in five cases, apposing stent placement were used. Overall mortality rate and procedure-related mortality rates were 22.5% (7/31) and 9.6% (3/31), respectively. At a mean imaging follow-up of 17.2 ± 12.6 months, total occlusion was achieved in 22 aneurysms (91.6%). Univariate analysis showed that mortality was positively correlated with vasospasm (ρ = 0.600, p < 0.05), higher mWFNS Scale (ρ = 0.685, p < 0.05), higher modified Fischer Score (ρ = 0.609, p < 0.05), higher mRS (ρ = 0.594, p < 0.05) on admission and negatively correlated with saccular morphology (ρ = -0.529, p < 0.05). Multivariate logistic regression identified mWFNS on admission as a significant predictor. (OR: 7.148, 95% CI 1.777-28.758, p: 0.01). Adjunctive coiling positively correlated with aneurysm occlusion. (ρ = 0.522, p < 0.05). CONCLUSION The procedure-related morbidity and mortality is not negligible. However, the risks and efficacy associated with FDs are acceptable, especially when adjunctive coiling is possible, given the lack of treatment alternatives.
Collapse
|
8
|
Triple therapy versus dual-antiplatelet therapy for dolichoectatic vertebrobasilar fusiform aneurysms treated with flow diverters. J Neurointerv Surg 2022:jnis-2022-019151. [DOI: 10.1136/jnis-2022-019151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 08/04/2022] [Indexed: 11/03/2022]
Abstract
BackgroundDolichoectatic vertebrobasilar fusiform aneurysms (DVBFAs) have poor natural history when left untreated and high morbimortality when treated with microsurgery. Flow diversion (FD) with dual-antiplatelet therapy (DAPT) is feasible but carries high risk of perforator occlusion and progression of brainstem compression. Elaborate antithrombotic strategies are needed to preserve perforator patency while vessel remodeling occurs. We compared triple therapy (TT (DAPT plus oral anticoagulation)) and DAPT alone in patients with DVBFAs treated with FD.MethodsRetrospective comparison of DAPT and TT in patients with DVBFAs treated with FD at eight US centers.ResultsThe groups (DAPT=13, TT=14) were similar in age, sex, clinical presentation, baseline disability, and aneurysm characteristics. Radial access use was significantly higher in the TT group (71.4% vs 15.3%; P=0.006). Median number of flow diverters and adjunctive coiling use were non-different between groups. Acute ischemic stroke rate during the oral anticoagulation period was lower in the TT group than the DAPT group (7.1% vs 30.8%; P=0.167). Modified Rankin Scale score decline was significantly lower in the TT group (7.1% vs 69.2%; P=0.001). Overall rates of hemorrhagic complications (TT, 28.6% vs DAPT, 7.7%; P=0.162) and complete occlusion (TT, 25% vs DAPT, 54.4%; P=0.213) were non-different between the groups. Rate of moderate-to-severe disability at last follow-up was significantly lower in the TT group (21.4% vs 76.9%; P=0.007).ConclusionsPatients with DVBFAs treated with FD in the TT group had fewer ischemic strokes, less symptom progression, and overall better outcomes at last follow-up than similar patients in the DAPT group.
Collapse
|
9
|
Use of flow diverter device in basilar artery for aneurysm treatment: Case series and literature review. Front Neurol 2022; 13:990308. [PMID: 36062016 PMCID: PMC9428249 DOI: 10.3389/fneur.2022.990308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Accepted: 07/26/2022] [Indexed: 11/17/2022] Open
Abstract
Background Flow diverters (FDs) for the treatment of basilar artery (BA) aneurysms remain controversial. In this study, we report our initial experience of flow diversion for treatment of this pathology. Methods Consecutive patients with an aneurysm of the BA that was treated by implantation of the FD were included in our retrospective study. Procedural complications, aneurysm occlusion, and a functional outcome were evaluated. FD placement in BA for aneurysm treatment reported in the literature was also reviewed and summarized. Results Sixteen patients with 16 BA aneurysms were treated by FD implantation with (n = 8) or without (n = 8) adjunctive coiling. The Tubridge was used in 13 (81.3%) and Pipeline in 3 (18.8%) procedures. Average aneurysm size was 15.7 mm. Four aneurysms were located at the basilar apex, six at the basilar trunk, and six at the vertebrobasilar junction. Three patients experienced procedural complications (18.8%), including two ischemic strokes and one hydrocephalus, with resultant mortality in one case (6.3%). Median follow-up was 7.7 months and available for 15 aneurysms. Complete/near-complete occlusion was seen in 13 (86.7%) aneurysms. Conclusion In our initial experience, flow diversion is feasible and safe in the treatment of BA aneurysms with promising occlusion rates at mid-term follow-up. Larger cohort studies are required to validate these results.
Collapse
|
10
|
Endovascular Treatment of Large or Giant Basilar Artery Aneurysms Using the Pipeline Embolization Device: Complications and Outcomes. Front Neurol 2022; 13:843839. [PMID: 35309591 PMCID: PMC8924535 DOI: 10.3389/fneur.2022.843839] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 02/08/2022] [Indexed: 01/11/2023] Open
Abstract
Background This study aimed to investigate clinical and angiographic outcomes of Pipeline embolization device (PED) treatment of large or giant basilar artery (BA) aneurysms and examine associated factors. Methods Clinical and angiographic data of 29 patients (18 men, 11 women) with large or giant BA aneurysms were retrospectively examined. Mean age was 44.1 ± 21.2 years (range, 30–68). Mean aneurysm size was 22.2 ± 8.3 mm (range, 12.0–40.1). Results Mean angiographic follow-up was 18.3 ± 3.4 months (range, 4.5–60). The rate of adequate aneurysmal occlusion (O'Kelly–Marotta grade C–D) was 87%. The overall complication rate was 44.8%; most complications (84.6%) occurred in the periprocedural period. Univariable comparison of patients who did and did not develop complications showed significant differences in aneurysm size (p < 0.01), intra-aneurysmal thrombus (p = 0.03), and mean number of PEDs used (p = 0.02). Aneurysm size (odds ratio, 1.4; p = 0.04) was an independent risk factor for periprocedural complications in multivariable analysis. Mean clinical follow-up was 23.5 ± 3.2 months (range, 0.1–65). Nine patients (31%) had a poor clinical outcome (modified Rankin scale score ≥3) at last follow-up, including 7 patients who died. Univariable comparisons between patients with favorable and unfavorable clinical outcomes showed that aneurysm size (p = 0.009) and intra-aneurysmal thrombus (p = 0.04) significantly differed between the groups. Multivariable analysis showed that aneurysm size (odds ratio, 1.1; p = 0.04) was an independent risk factor for poor clinical outcome. Conclusion PED treatment of large or giant BA aneurysms is effective and can achieve a satisfactory long-term occlusion rate. However, the treatment complications are not negligible. Aneurysm size is the strongest predictor of perioperative complications and poor clinical outcome.
Collapse
|
11
|
Comprehensive review of the recent advances in devices for endovascular treatment of complex brain aneurysms. Br J Radiol 2022; 95:20210538. [PMID: 34609898 PMCID: PMC8722252 DOI: 10.1259/bjr.20210538] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
The International Subarachnoid Aneurysm Trial (ISAT) showed superiority for endovascular treatment of ruptured aneurysms and technology has since moved on rapidly. Many approaches and technology now exist for the endovascular management of ruptured and unruptured intracranial aneurysms, which reflects their varied nature - there is no one-size-fits-all technique. We aim to provide an overview of the various classes of device and the major developments over the past decade. Coiling is the oldest of the technology and continues to demonstrate high levels of occlusion and acceptable risks, making it the default treatment choice, particularly in the acutely ruptured aneurysm setting. Advances on coiling include the use of adjuncts such as balloons, stents and fully retrievable temporary neck-bridging devices, which have facilitated the treatment of more complex aneurysms. Flow divertors have also revolutionised complex aneurysm treatment with small added risk in acute aneurysm treatment and seek to remodel the aneurysm-vessel interface without accessing the aneurysm sac. The latest development and most promising avenue appears to be intrasaccular flow disrupting devices like WEB, Contour and Neqstent that provide excellent opportunities to treat wide neck complex aneurysm with minimal mortality and morbidity and good occlusion rates and may in future replace a significant number of stent-assisted coiling too.
Collapse
|
12
|
Flow Diversion of Posterior Circulation Aneurysms: Systematic Review of Disaggregated Individual Patient Data. AJNR Am J Neuroradiol 2021; 42:1827-1833. [PMID: 34385140 DOI: 10.3174/ajnr.a7220] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 04/29/2021] [Indexed: 12/30/2022]
Abstract
BACKGROUND Experience with endoluminal flow diversion for the treatment of posterior circulation aneurysms is limited. PURPOSE We sought to investigate factors associated with the safety and efficacy of this treatment by collecting disaggregated patient-level data from the literature. DATA SOURCES PubMed, EMBASE, and Ovid were searched up through 2019 for articles reporting flow diversion of posterior circulation aneurysms. STUDY SELECTION Eighty-four studies reported disaggregated data for 301 separate posterior circulation aneurysms. DATA ANALYSIS Patient, aneurysm, and treatment factors were collected for each patient. Outcomes included the occurrence of major complications, angiographic occlusion, and functional outcomes based on the mRS. DATA SYNTHESIS Significant differences in aneurysm and treatment characteristics were seen among different locations. Major complications occurred in 22%, angiographic occlusion was reported in 65% (11.3 months of mean follow-up), and good functional outcomes (mRS 0-2) were achieved in 67% (13.3 months of mean follow-up). Multivariate analysis identified age, number of flow diverters used, size, and prior treatment to be associated with outcome measures. Meta-analysis combining the current study with prior large nondisaggregated series of posterior circulation aneurysms treated with flow diversion found a pooled incidence of 20% (n = 712 patients) major complications and 75% (n = 581 patients) angiographic occlusions. LIMITATIONS This study design is susceptible to publication bias. Use of antiplatelet therapy was not uniformly reported. CONCLUSIONS Endoluminal flow diversion is an important tool in the treatment of posterior circulation aneurysms. Patient age, aneurysm size, prior treatment, and the number of flow diverters used are important factors associated with complications and outcomes.
Collapse
|
13
|
Efficacy and safety of flow diverters in posterior circulation aneurysms and comparison with their efficacy in anterior circulation aneurysms: A systematic review and meta-analysis. Interv Neuroradiol 2021; 27:609-621. [PMID: 33752478 PMCID: PMC8493351 DOI: 10.1177/15910199211003017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 01/21/2021] [Accepted: 02/10/2021] [Indexed: 11/16/2022] Open
Abstract
PURPOSE We aimed to assess the efficacy and safety of flow-diverter stents (FDs) in the management of posterior circulation cerebral aneurysms and compare FD efficacy between anterior and posterior circulation aneurysms. METHODS We searched the PubMed, Scopus, Cochrane, and Web of Science databases for relevant studies through March 2020. Studies assessing FDs for posterior circulation aneurysms that included ≥20 treated aneurysms were included. Moreover, the studies compared FD efficacy between anterior and posterior circulation aneurysms were included. Data regarding angiographic aneurysmal occlusion, procedural complications, mortality, and morbidity were extracted and pooled in a random-effects meta-analysis model. RESULTS Fourteen studies with a total of 659 patients and 676 posterior circulation aneurysms were included. The pooled rate of aneurysmal occlusion at long-term angiographic follow-up was 78% [95% confidence interval (CI), 71-85]. The pooled rates of intraparenchymal hemorrhage, ischemia, and procedure-related mortality and neurological morbidity were 2%, 8%, 7%, and 6%, respectively. Complete occlusion occurred in 82.4% of the posterior circulation aneurysm subgroup and 77.5% of the anterior circulation aneurysm subgroup. The difference was not significant (relative risk 1.01; 95% CI, 0.86-1.19; p = 0.91). Regression analysis showed that elderly patients and females had higher morbidity. CONCLUSION Posterior circulation aneurysms can be effectively treated with FDs with comparable occlusion rates to those in anterior circulation aneurysms. However, periprocedural complications are not negligible.
Collapse
|
14
|
Double Barrel Stent-supported Supranominal Flow Diverter Expansion for Treatment of Symptomatic Basilar Trunk Aneurysm : Technical Note. Clin Neuroradiol 2021; 32:863-867. [PMID: 34498095 DOI: 10.1007/s00062-021-01088-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 08/12/2021] [Indexed: 10/20/2022]
|
15
|
Intracranial aneurysms managed by parent artery reconstruction using Tubridge: Study protocol for a prospective, multicenter, post-market clinical trial. Interv Neuroradiol 2020; 27:490-496. [PMID: 33236687 DOI: 10.1177/1591019920976233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND As a new endovascular reconstruction technique, flow diverter (FD) shows excellent efficacy and safety for treatment of intracranial aneurysms. In a previous multicenter, randomized, controlled, pre-market study, Tubridge FD showed remarkably higher complete occlusion rate compared with traditional stent-assisted coiling. However, a nonsignificant higher complication rate in the Tubridge group was noted. Considering the learning curve, the safety, and long-term outcomes of Tubridge FD should be verified in new prospective, real world, multicenter, post-market trials. METHODS This study is a prospective, multicenter, single-arm, post-market clinical trial that evaluates the safety and efficacy of Tubridge in the treatment of patients with intracranial aneurysms by reconstructing parent artery. We expect 200 participants who meet the inclusion and exclusion criteria to be included. Clinical information and angiographic results (Raymond-Roy grading scale, RRGS) will be recorded objectively. The primary endpoint will be the complete occlusion rate of the target aneurysm (RRGS 1) at 12-month follow-up. Secondary endpoints will include the adequate occlusion rate (RRGS 1 & 2) and the rate of major in-stent stenosis (>50%) at 12-month follow-up, technique success rate, changes of modified Rankin Scale before and after the procedure, the rate of aneurysm related disability, neurological mortality, and all-cause mortality within follow-up period. DISCUSSION This post-market, prospective trial may offer more information on the safety and long-term outcomes of Tubridge FD. When the study is complete, the results may provide us a new strategy for the treatment of intracranial aneurysms.Trial registration: WHO-Chinese Clinical Trial Registry: ChiCTR2000032282.
Collapse
|
16
|
Overview of Different Flow Diverters and Flow Dynamics. Neurosurgery 2020; 86:S21-S34. [PMID: 31838536 DOI: 10.1093/neuros/nyz323] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Accepted: 04/30/2019] [Indexed: 12/16/2022] Open
Abstract
Over the past decade, flow diverter technology for endocranial aneurysms has seen rapid evolution, with the development of new devices quickly outpacing the clinical evidence base. However, flow diversion has not yet been directly compared to surgical aneurysm clipping or other endovascular procedures. The oldest and most well-studied device is the Pipeline Embolization Device (PED; Medtronic), recently transitioned to the Pipeline Flex (Medtronic), which still has sparse data regarding outcomes. To date, other flow diverting devices have not been shown to outperform the PED, although information comes primarily from retrospective studies with short follow-up, which are not always comparable. Because of this lack of high-quality outcome data, no reliable recommendations can be made for choosing among flow diversion devices yet. Moreover, the decision to proceed with flow diversion should be individualized to each patient. In this work, we wish to provide a comprehensive overview of the technical specifications of all flow diverter devices currently available, accompanied by a succinct description of the evidence base surrounding each device.
Collapse
|
17
|
Expanding the Indications for Flow Diversion: Treatment of Posterior Circulation Aneurysms. Neurosurgery 2020; 86:S76-S84. [PMID: 31838535 DOI: 10.1093/neuros/nyz344] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Accepted: 07/02/2019] [Indexed: 11/14/2022] Open
Abstract
Posterior circulation aneurysms are often associated with a higher risk of rupture and compressive symptoms compared to their anterior circulation counterpart. Due to high morbidity and mortality associated with microsurgical treatment of those aneurysms, endovascular therapy gained ascendance as the preferred method of treatment. Flow diversion has emerged as a promising treatment option for posterior circulation aneurysms with a higher occlusion rate compared to other endovascular techniques and a lower complication rate compared to microsurgery. While treatment of saccular and dissecting aneurysms is often associated with comparatively good outcomes, fusiform and dolichoectatic aneurysms should be carefully selected prior to treatment to avoid devastating thromboembolic complications. Occlusion of covered posterior circulation branches showed no correlation with ischemic complications, and appropriate antiplatelet regimen and switching Clopidogrel nonresponders to different antiplatelet agents were associated with lower complication rates following flow diversion of posterior circulation aneurysms.
Collapse
|
18
|
Pipeline Embolization in Patients with Posterior Circulation Subarachnoid Hemorrhages: Is Takotsubo Cardiomyopathy a Limiting Factor? World Neurosurg 2020; 143:e523-e528. [DOI: 10.1016/j.wneu.2020.08.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 07/31/2020] [Accepted: 08/01/2020] [Indexed: 12/17/2022]
|
19
|
Review of current intracranial aneurysm flow diversion technology and clinical use. J Neurointerv Surg 2020; 13:54-62. [PMID: 32978269 DOI: 10.1136/neurintsurg-2020-015877] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 09/04/2020] [Accepted: 09/10/2020] [Indexed: 02/07/2023]
Abstract
Endovascular treatment of intracranial aneurysms (IAs) has evolved considerably over the past decades. The technological advances have been driven by the experience that coils fail to completely exclude all IAs from the blood circulation, the need to treat the diseased parent vessel segment leading to the aneurysm formation, and expansion of endovascular therapy to treat more complex IAs. Stents were initially developed to support the placement of coils inside wide neck aneurysms. However, early work on stent-like tubular braided structure led to a more sophisticated construct that then later was coined as a flow diverter (FD) and found its way into clinical application. Although FDs were initially used to treat wide-neck large and giant internal carotid artery aneurysms only amenable to surgical trap with or without a bypass or endovascular vessel sacrifice, its use in other types of IAs and cerebrovascular pathology promptly followed. Lately, we have witnessed an explosion in the application of FDs and subsequently their modifications leading to their ubiquitous use in endovascular therapy. In this review we aim to compile the available FD technology, evaluate the devices' peculiarities from the authors' perspective, and analyze the current literature to support initial and expanded indications, recognizing that this may be outdated soon.
Collapse
|
20
|
Derivo embolization device in the treatment of unruptured intracranial aneurysms: a prospective multicenter study. J Neurointerv Surg 2020; 13:541-546. [PMID: 32900908 PMCID: PMC8142444 DOI: 10.1136/neurintsurg-2020-016303] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 07/24/2020] [Accepted: 07/26/2020] [Indexed: 11/24/2022]
Abstract
Background Flow diverters (FD) are used regularly for the endovascular treatment of unruptured intracranial aneurysms. We aimed to assess the safety and effectiveness of the Derivo embolization device (DED) with respect to long-term clinical and angiographic outcomes. Methods A prospective multicenter trial was conducted at 12 centers. Patients presenting with modified Rankin Score (mRS) of 0–1, treated for unruptured intracranial aneurysms with DED were eligible. Primary endpoint was the mRS assessed at 18 months with major morbidity defined as mRS 3–5. Satisfactory angiographic occlusion was defined as 3+4 on the Kamran scale. Results Between July 2014 and February 2018, 119 patients were enrolled. Twenty-three patients were excluded. Ninety-six patients, 71 (74%) female, mean age 54±12.0 years, were included in the analysis. Mean aneurysm size was 14.2±16.9 mm. The mean number of devices implanted per patient was 1.2 (range 1–3). Clinical follow-up at 18 months was available in 90 (94%) patients, resulting in a mean follow-up period of 14.8±5.2 months. At last available follow-up of 96 enrolled patients, 91 (95%) remained mRS 0–1. The major morbidity rate (mRS 3–5) was 3.1% (3/96), major stroke rate was 4.2% (4/96), and mortality was 0%. Follow-up angiographies were available in 89 (93%) patients at a median of 12.4±5.84 months with a core laboratory adjudicated satisfactory aneurysm occlusion in 89% (79/89). Conclusion Our results suggest that DED is a safe and effective treatment for unruptured aneurysms with high rates of satisfactory occlusion and comparably low rates of permanent neurological morbidity and mortality. Trial registration DRKS00006103
Collapse
|
21
|
Advances in endovascular aneurysm management: flow modulation techniques with braided mesh devices. Stroke Vasc Neurol 2020; 5:1-13. [PMID: 32411402 PMCID: PMC7213520 DOI: 10.1136/svn-2020-000347] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Accepted: 02/28/2020] [Indexed: 02/07/2023] Open
Abstract
Flow diverters and flow disruption technology, alongside nuanced endovascular techniques, have ushered in a new era of treating cerebral aneurysms. Here, we provide an overview of the latest flow modulation devices and highlight their clinical applications and outcomes.
Collapse
|
22
|
Multimodal management of giant cerebral aneurysms: review of literature and case presentation. Stroke Vasc Neurol 2020; 5:22-28. [PMID: 32411404 PMCID: PMC7213518 DOI: 10.1136/svn-2019-000304] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 02/18/2020] [Accepted: 02/27/2020] [Indexed: 12/27/2022] Open
Abstract
The pathophysiology of giant cerebral aneurysms renders them difficult to treat. Advances in technology have attempted to address any shortcomings associated with open surgery or endovascular therapies. Since the introduction of the flow diversion technique, the endovascular approach with flow diversion has become the first-line modality chosen to treat giant aneurysms. A subset of these giant aneurysms may persistent despite any treatment modality. Perhaps the best option for these recurrent and/or persistent giant aneurysms is to employ a multimodal approach-both surgical and endovascular-rather than any single technique to provide a curative result with favourable patient outcomes. This paper provides a review of the histopathology and treatment options for giant cerebral aneurysms. Additionally, an illustrative case is presented to highlight the unique challenges of a curative solution for giant cerebral aneurysms that persist despite initial treatment.
Collapse
|
23
|
The Evolution of Flow-Diverting Stents for Cerebral Aneurysms; Historical Review, Modern Application, Complications, and Future Direction. J Korean Neurosurg Soc 2020; 63:137-152. [PMID: 32120455 PMCID: PMC7054118 DOI: 10.3340/jkns.2020.0034] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Accepted: 02/19/2020] [Indexed: 12/12/2022] Open
Abstract
In spite of the developing endovascular era, large (15–25 mm) and giant (>25 mm) wide-neck cerebral aneurysms remained technically challenging. Intracranial flow-diverting stents (FDS) were developed to address these challenges by targeting aneurysm hemodynamics to promote aneurysm occlusion. In 2011, the first FDS approved for use in the United States market. Shortly thereafter, the Pipeline of Uncoilable or Failed Aneurysms (PUFS) study was published demonstrating high efficacy and a similar complication profile to other intracranial stents. The initial FDA instructions for use (IFU) limited its use to patients 22 years old or older with wide-necked large or giant aneurysms of the internal carotid artery (ICA) from the petrous segment to superior hypophyseal artery/ophthalmic segment. Expanded IFU was tested in the Prospective Study on Embolization of Intracranial Aneurysms with PipelineTM Embolization Device (PREMIER) trial. With further post-approval clinical data, the United States FDA expanded the IFU to include patients with small or medium, wide-necked saccular or fusiform aneurysms from the petrous ICA to the ICA terminus. However, IFU is more restrictive in South Korea than in United States. Several systematic reviews and meta-analyses have sought to evaluate the overall efficacy of FDS for the treatment of cerebral aneurysms and consistently identify FDS as an effective technique for the treatment of aneurysms broadly with complication rates similar to other traditional techniques. A growing body of literature has demonstrated high efficacy of FDS for small aneurysms; distal artery aneurysms; non-saccular aneurysms posterior circulation aneurysms and complication rates similar to traditional techniques. In the short interval since the Pipeline Embolization Device was first introduced, FDS has been firmly entrenched as a powerful tool in the endovascular armamentarium. As new FDS are developed, established FDS are refined, and delivery systems are improved the uses for FDS will only expand further. Researchers continue to work to optimize the mechanical characteristics of the FDS themselves, aiming to optimize deploy ability and efficacy. With expanded use for small to medium aneurysms and posterior circulation aneurysms, FDS technology is firmly entrenched as a powerful tool to treat challenging aneurysms, both primarily and as an adjunct to coil embolization. With the aforementioned advances, the ease of FDS deployment will improve and complication rates will be further minimized. This will only further establish FDS deployment as a key strategy in the treatment of cerebral aneurysms.
Collapse
|
24
|
First clinical experience with the new Surpass Evolve flow diverter: technical and clinical considerations. J Neurointerv Surg 2020; 12:974-980. [DOI: 10.1136/neurintsurg-2019-015734] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 01/21/2020] [Accepted: 01/27/2020] [Indexed: 11/04/2022]
Abstract
ObjectiveTo describe the results in patients treated with the Surpass Evolve (SE) device, the new generation of Surpass flow diverters.MethodsTwenty-five consecutive patients (20 women, average age 58 years), with anterior or posterior circulation aneurysms treated with SEs in two early-user centers, were included. Device properties and related technical properties, imaging and clinical follow-up data, and intraprocedural, early (<30 days) and delayed (>30 days) neurological complications, further divided into minor (silent/non-permanent) and major (permanent) complications, were recorded and analyzed.ResultsTwenty-nine SEs were successfully implanted in all subjects to treat 26 aneurysms using an 0.027" microcatheter with an average of 1.2 stents per patient. No intraprocedural thromboembolic or hemorrhagic complications were seen. At clinical follow-up, 24/25 (96%) patients had a modified Rankin Score of 0–2. Mortality was 0%. Imaging follow-up, available in 22/25 (88%) patients (median follow-up time 4 months), showed a complete aneurysm occlusion in 13/23 (57%) imaged lesions. Minor, transitory neurological deficits were recorded in 5/25 (20%) patients. One (4%) major complication was seen in one patient (4%) with a left-sided hemispheric stroke on postprocedural day 4 due to an acute stent thrombosis.ConclusionsPreliminary experience in patients demonstrates a good performance of the SE. This newly designed implant maintains the engineering characteristics of Surpass flow diverters, including precise placement due to its lower foreshortening and a high mesh density, yet can be deployed through a significantly lower-profile delivery system.
Collapse
|
25
|
Endovascular Treatment of Posterior Cerebral Artery Aneurysms With Flow Diversion: Case Series and Systematic Review. Neurosurgery 2019. [PMID: 29528441 DOI: 10.1093/neuros/nyx561] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Flow diversion of posterior cerebral artery (PCA) aneurysms has not been widely reported, possibly owing to concerns regarding parent vessel size and branch vessel coverage. OBJECTIVE To examine the safety and effectiveness of PCA aneurysm flow diverter treatment. METHODS Retrospective review of PCA aneurysms treated with the Pipeline Embolization Device (PED; Medtronic Inc, Dublin, Ireland) at 3 neurovascular centers, including periprocedural complications and clinical and angiographic outcomes. Systematic review of the literature identified published reports of PCA aneurysms treated with flow diversion. Rates of aneurysm occlusion and complications were calculated, and outcomes of saccular and fusiform aneurysm treatments were compared. RESULTS Ten PCA aneurysms in 9 patients were treated with the PED. There were 2 intraprocedural thromboembolic events (20%), including 1 symptomatic infarction and 1 delayed PED thrombosis. Eight of 10 patients returned to or improved from their baseline functional status. Complete aneurysm occlusion with parent vessel preservation was achieved in 75% (6/8) of cases at mean follow-up of 16.7 mo. Eleven of 12 (92%) major branch vessels covered by a PED remained patent. Including the present study, systematic review of 15 studies found a complete aneurysm occlusion rate of 88% (30/34) and complication rate of 26% (10/38), including 5 symptomatic ischemic strokes (13%; 5/38). Fusiform aneurysms more frequently completely occluded compared with saccular aneurysms (100% vs 70%; P = .03) but were associated with a higher complication rate (43% vs 9%; P = .06). CONCLUSION The safety and effectiveness profile of flow diverter treatment of PCA aneurysms may be acceptable in select cases.
Collapse
|
26
|
Flow diversion treatment for acutely ruptured aneurysms. J Neurointerv Surg 2019; 12:283-288. [DOI: 10.1136/neurintsurg-2019-015077] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2019] [Revised: 08/04/2019] [Accepted: 08/07/2019] [Indexed: 11/04/2022]
Abstract
Background and purposeFlow diverters are sometimes used in the setting of acutely ruptured aneurysms. However, thromboembolic and hemorrhagic complications are feared and evidence regarding safety is limited. Therefore, in this multicenter study we evaluated complications, clinical, and angiographic outcomes of patients treated with a flow diverter for acutely ruptured aneurysms.MethodsWe conducted a retrospective observational study of 44 consecutive patients who underwent flow diverter treatment within 15 days after rupture of an intracranial aneurysm at six centers. The primary end point was good clinical outcome, defined as modified Rankin Scale score (mRS) 0–2. Secondary endpoints were procedure-related complications and complete aneurysm occlusion at follow-up.ResultsAt follow-up (median 3.4 months) 20 patients (45%) had a good clinical outcome. In 20 patients (45%), 25 procedure-related complications occurred. These resulted in permanent neurologic deficits in 12 patients (27%). In 5 patients (11%) aneurysm re-rupture occurred. Eight patients died resulting in an all-cause mortality rate of 18%. Procedure-related complications were associated with a poor clinical outcome (mRS 3–6; OR 5.1(95% CI 1.0 to 24.9), p=0.04). Large aneurysms were prone to re-rupture with rebleed rates of 60% (3/5) vs 5% (2/39) (p=0.01) for aneurysms with a size ≥20 mm and <20 mm, respectively. Follow-up angiography in 29 patients (median 9.7 months) showed complete aneurysm occlusion in 27 (93%).ConclusionFlow diverter treatment of ruptured intracranial aneurysms was associated with high rates of procedure-related complications including aneurysm re-ruptures. Complications were associated with poor clinical outcome. In patients with available angiographic follow-up, a high occlusion rate was observed.
Collapse
|
27
|
Single-center experience with six-month follow-up of FRED Jr® flow diverters for intracranial aneurysms in small arteries. Acta Radiol 2019; 60:917-924. [PMID: 30354188 DOI: 10.1177/0284185118805266] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
28
|
On Flow Diversion: The Changing Landscape of Intracerebral Aneurysm Management. AJNR Am J Neuroradiol 2019; 40:591-600. [PMID: 30894358 DOI: 10.3174/ajnr.a6006] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 01/25/2019] [Indexed: 12/15/2022]
Abstract
Uptake of flow-diverting technology is rapidly outpacing the availability of clinical evidence. Most current usage is off-label, and the endovascular community is nearer the beginning than the end of the learning curve, given the number of devices in development. A comprehensive overview of technical specifications alongside key outcome data is essential both for clinical decision-making and to direct further investigations. Most-studied has been the Pipeline Embolization Device, which has undergone a transition to the Pipeline Flex for which outcome data are sparse or heterogeneous. Alternative endoluminal devices do not appear to be outperforming the Pipeline Embolization Device to date, though prospective studies and long-term data mostly are lacking, and between-study comparisons must be treated with caution. Nominal technical specifications may be unrelated to in situ performance, emphasizing the importance of correct radiologic sizing and device placement. Devices designed specifically for bifurcation aneurysms also lack long-term outcome data or have only recently become available for clinical use. There are no major studies directly comparing a flow-diverting device with standard coiling or microsurgical clipping. Data on flow-diverting stents are too limited in terms of long-term outcomes to reliably inform clinical decision-making. The best available evidence supports using a single endoluminal device for most indications. Recommendations on the suitability and choice of a device for bifurcation or ruptured aneurysms or for anatomically complex lesions cannot be made on the basis of current evidence. The appropriateness of flow-diverting treatment must be decided on a case-by-case basis, considering experience and the relative risks against standard approaches or observation.
Collapse
|
29
|
Treatment of posterior inferior cerebellar artery aneurysms using flow-diverter stents: A single-center experience. Interv Neuroradiol 2019; 25:407-413. [PMID: 30803331 DOI: 10.1177/1591019918824003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
INTRODUCTION The effectiveness and reliability of flow-diverter stents, which are commonly used in aneurysms of the anterior circulation, have been demonstrated previously. However, the use of these devices is associated with higher rates of perforator and branch ischemia following the treatment of aneurysms of the posterior circulation. METHODS This work involved a single-center; retrospective study reviewing eight patients who had aneurysms related to the posterior inferior cerebellar artery (PICA) and who were treated with flow-diverter stents from September 2013 to May 2017. RESULTS The mean aneurysm diameter was 7.6 mm (range, 5 to 11 mm). The types of aneurysm included five aneurysms that were saccular, two that were fusiform, and one that was dissecting. All saccular aneurysms in the neck involved the PICA origin, and one dissecting aneurysm was localized in the proximal part of the PICA. Procedural success was 100% (8/8), and there were no ischemic complications. One patient with subarachnoid hemorrhage died because of rebleeding (modified Rankin Scale (mRS), 6). Other than this patient all of the patients' mRS scores were zero at discharge and at the clinical follow-up period (mean, 2.5 years). All of the aneurysms were completely occluded according to the latest angiographic controls (mean follow-up period of 19.5 months). CONCLUSIONS Treatment of PICA aneurysms with flow-diverter stents showed positive results with a high rate of technical success and low complication and mortality rates. The use of flow-diverter stents in the treatment of PICA aneurysms should be considered a safe and effective endovascular treatment option.
Collapse
|
30
|
Endovascular Metal Devices for the Treatment of Cerebrovascular Diseases. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1805452. [PMID: 30589125 DOI: 10.1002/adma.201805452] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 09/20/2018] [Indexed: 06/09/2023]
Abstract
Cerebrovascular disease involves various medical disorders that obstruct brain blood vessels or deteriorate cerebral circulation, resulting in ischemic or hemorrhagic stroke. Nowadays, platinum coils with or without biological modification have become routine embolization devices to reduce the risk of cerebral aneurysm bleeding. Additionally, many intracranial stents, flow diverters, and stent retrievers have been invented with uniquely designed structures. To accelerate the translation of these devices into clinical usage, an in-depth understanding of the mechanical and material performance of these metal-based devices is critical. However, considering the more distal location and tortuous anatomic characteristics of cerebral arteries, present devices still risk failing to arrive at target lesions. Consequently, more flexible endovascular devices and novel designs are under urgent demand to overcome the deficiencies of existing devices. Herein, the pros and cons of the current structural designs are discussed when these devices are applied to the treatment of diseases ranging broadly from hemorrhages to ischemic strokes, in order to encourage further development of such kind of devices and investigation of their use in the clinic. Moreover, novel biodegradable materials and drug elution techniques, and the design, safety, and efficacy of personalized devices for further clinical applications in cerebral vasculature are discussed.
Collapse
|
31
|
Preliminary experience with the use of low profile visualized intraluminal support device in basilar artery for aneurysm treatment. J Neurointerv Surg 2018; 11:405-410. [PMID: 30415230 DOI: 10.1136/neurintsurg-2018-014393] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 10/09/2018] [Accepted: 10/16/2018] [Indexed: 11/04/2022]
Abstract
BACKGROUND The low profile visualized intraluminal support (LVIS) device is being increasingly used for the treatment of intracranial aneurysms. Its application in the basilar artery (BA) has not yet been reported. OBJECTIVE To evaluate the safety and early efficacy of the LVIS device for the treatment of BA aneurysms. METHODS A prospectively maintained database was retrospectively reviewed for all patients with BA aneurysms treated by LVIS stents at our institution. Angiographic results were evaluated using the modified Raymond-Roy classification (mRRC). RESULTS 23 patients (mean age 52.8 years) with a BA aneurysm that was treated by LVIS stent implantation, with (n=21) or without (n=2) adjunctive coiling, were included in our study. 7 aneurysms were treated in the setting of subarachnoid hemorrhage (SAH). 10 aneurysms were located at the basilar tip, 10 at the basilar trunk, and 3 at the superior cerebellar artery. Procedure related complications developed in three patients (13%), including two perforator infarction and one worsening mass effect. Complications resulted in permanent morbidity (4%) in one case. One fatality was related to severe poor grade SAH. At a mean follow-up of 6.9 months, 13 of the 20 patients were mRRC I closure, 3 were mRRC II closure with an improvement from class IIIa, 3 were observed to be recanalized from class IIIa to IIIb, and 1 with stenting only was still patent similar to the immediate angiography. CONCLUSION The LVIS stent represents a feasible and safe option for endovascular embolization of BA aneurysms. Although recanalization may occur after LVIS treatment, the mid term complete occlusion rate was acceptable.
Collapse
|
32
|
Intermediate catheter placement distal to the cerebral aneurysm during flow diversion embolization with the Surpass device. J Neurointerv Surg 2018; 10:e35. [DOI: 10.1136/neurintsurg-2017-013662] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 03/05/2018] [Accepted: 03/06/2018] [Indexed: 11/04/2022]
Abstract
PurposeWe present the preliminary angiographic and clinical results of the combined utilization of an AXS Catalyst 5 (Cat5) distal access catheter and a Surpass flow diverter (SFD) for the endovascular treatment of intracranial aneurysms.Materials and methodsInterventional neuroradiology case records were evaluated retrospectively to identify patients treated with an SFD in combination with Cat5. Demographic data, technical success, location of the catheter tip, aneurysm occlusion rate, and procedure-related morbidity and mortality were noted.ResultsThe analysis yielded 24 patients with 25 aneurysms with a mean age of 52.3±19.7 years. The mean aneurysm diameter was 15.7±8.8 mm. Twenty-one were anterior circulation (seven supraclinoid, one middle cerebral, one anterior choroidal and 12 petrocavernous) and four were posterior circulation (three basilar tip, one posterior inferior cerebellar) aneurysms. Only two of these aneurysms were re-treatments for recurrences. For SFD deployment, the distal tip of Cat5 was placed intradurally and at, or distal to, M1 segment in 88% and 48% of patients, respectively. Aneurysms were bypassed with Cat5 in 80% of the procedures. In one patient, flow diversion was abandoned totally due to arterial tortuosity. With the exclusion of this patient, the technical success rate was 91.7%. There was no permanent procedure-related morbidity or mortality. Of the 22 aneurysms treated successfully with the Surpass device, 20 had imaging follow-up at 6.3±3.8 months and 95% were totally occluded.ConclusionThe Cat5 catheter, which was manufactured for the navigation of large-bore stent-like devices, is a useful adjunct to the Surpass device and allowed us to deploy the device safely.
Collapse
|