1
|
Jung EM, Kaiser U, Herr W, Stroszczynski C, Jung F. Novel high-resolution contrast agent ultrasound techniques HiFR CEUS and SR CEUS in combination with shear wave elastography, fat assessment and viscosity of liver parenchymal changes and tumors. Clin Hemorheol Microcirc 2024; 86:263-273. [PMID: 38489171 DOI: 10.3233/ch-249103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2024]
Abstract
BACKGROUND The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS Of n = 70 (mean value 48,3 years±20,3 years, range 18-84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis.
Collapse
Affiliation(s)
- Ernst Michael Jung
- Interdisciplinary Ultrasound Department, Institute of Diagnostic Radiology, University Hospital Regensburg, Regensburg, Germany
| | - Ulrich Kaiser
- Clinic and Polyclinic for Internal Medicine III, University Hospital Regensburg, Regensburg, Germany
| | - Wolfgang Herr
- Clinic and Polyclinic for Internal Medicine III, University Hospital Regensburg, Regensburg, Germany
| | - Christian Stroszczynski
- Interdisciplinary Ultrasound Department, Institute of Diagnostic Radiology, University Hospital Regensburg, Regensburg, Germany
| | - Friedrich Jung
- Molecular Cell Biology, Institute of Biotechnology, Brandenburg University of Technology, Senftenberg, Germany
| |
Collapse
|
2
|
Schleder S, Jung EM, Schicho A, Schreyer AG, Habicher W, Grassinger J, Dollinger M. Efficacy and safety of ultrasound-guided core needle biopsies (US-CNBs) in cervical lymphadenopathy in patients with suspected head and neck cancer during the COVID-19 pandemic. Clin Hemorheol Microcirc 2023; 83:397-408. [PMID: 36683499 DOI: 10.3233/ch-221680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
BACKGROUND Cervical lymphadenopathy can be benign or malignant. Its accurate diagnosis is necessary to determine appropriate treatment. Ultrasound-guided core needle biopsies (US-CNBs) are frequently used as a percutaneous sampling approach. OBJECTIVES Our aim was to identify the efficacy and safety of US-CNBs in 125 patients with cervical lymphadenopathy and clinically suspected head and neck cancer during the COVID-19 pandemic with limited surgical resources. METHODS US-CNBs of pathological lymph nodes were performed in 146 lymph nodes on 125 patients. Biopsies were performed ultrasound-guided with a reusable gun core biopsy system and a 10-cm-long 16-G needle. Standard of reference for the histological findings were panendoscopy, clinical and sonographic follow-up, surgical biopsy or a repeat US-CNB. RESULTS Adequate material for histologic diagnosis was obtained in 111 patients (89%), of these 83 patients (75%) were diagnosed as malignant, whereas benign lymphadenopathy accounted for 28 patients (25%). Therefore, US-CNB was able to identify malignant or benign lymphadenopathy with an overall accuracy of 88% and 90%, respectively. CONCLUSIONS Percutaneous US-CNB is a safe and effective alternative to surgical biopsy in the management of cervical lymphadenopathy in patients with clinically suspected head and neck cancer in a setting with limited resources.
Collapse
Affiliation(s)
- Stephan Schleder
- Department of Diagnostic and Interventional Radiology, Merciful Brothers Hospital St. Elisabeth, Straubing, Germany
| | - Ernst-Michael Jung
- Department of Radiology, University Medical Center Regensburg, Regensburg, Germany
| | - Andreas Schicho
- Department of Radiology, University Medical Center Regensburg, Regensburg, Germany
| | - Andreas G Schreyer
- Department of Diagnostic and Interventional Radiology, University Hospital Brandenburg, Brandenburg Medical School Theodor Fontane, Neuruppin, Germany
| | - Werner Habicher
- Department of Othorhinolaryngology, Merciful Brothers Hospital St. Elisabeth, Straubing, Germany
| | - Jochen Grassinger
- Department of Hematology and Oncology, Merciful Brothers Hospital St. Elisabeth, Straubing, Germany
| | - Marco Dollinger
- Department of Radiology, University Medical Center Regensburg, Regensburg, Germany
| |
Collapse
|
3
|
Ren L, Zhao Y, Xiao J, Li M, Zhang Y, Zhu L, Luo Y. Contrast-enhanced ultrasound in evaluating the severity of acute kidney injury: An animal experimental study. Clin Hemorheol Microcirc 2023; 85:447-458. [PMID: 37718787 DOI: 10.3233/ch-231940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/19/2023]
Abstract
PURPOSE Early assessment of the severity of acute kidney injury (AKI) is critical to the prognosis of patients. Renal microcirculation hemodynamic changes and inflammatory response are the essential links of AKI induced by ischemia-reperfusion injury (IRI). This study aims to explore the value of contrast-enhanced ultrasound (CEUS) based on vascular cell adhesion molecule-1 (VCAM-1) targeted microbubbles (TM) in evaluating the renal microcirculation hemodynamics and inflammatory response of different severity of AKI. METHODS Eighteen male C57BL/6J mice were randomly divided into three groups (n = 6): sham operation (sham) group, mild IRI-AKI (m-AKI) group, and severe IRI-AKI (s-AKI) group. CEUS based on VCAM-1 TM was used to evaluate renal microcirculation perfusion and inflammatory response. Pearson's correlation was used to analyze the correlation between ultrasonic variables and pro-inflammatory factors. RESULTS Compared with the sham group, AUC in m-AKI and s-AKI groups was significantly decreased, and s-AKI group was lower than m-AKI group (P < 0.05). NID of m-AKI and s-AKI groups was significantly higher than that of the sham group, and s-AKI group was higher than that of m-AKI group (P < 0.05). There was a linear positive correlation between NID and VCAM-1 protein expression (r = 0.7384, P < 0.05). NID and AUC were correlated with TNF-α and IL-6 levels (P < 0.05). Compared with early AKI biomarkers, CEUS based on VCAM-1 TM has higher sensitivity in evaluating the severity of AKI. CONCLUSIONS CEUS based on VCAM-1 TM can evaluate renal microcirculation perfusion and inflammatory response in mild and severe AKI, which may provide helpful information for assessing the severity of AKI.
Collapse
Affiliation(s)
- Ling Ren
- The Second Medical College of Lanzhou University, Lanzhou, Gansu, China
- Department of Ultrasound, First Medical Center of Chinese PLA General Hospital, Beijing, China
- Department of Nephrology, First Medical Center of Chinese PLA General Hospital, Nephrology Institute of the Chinese People's Liberation Army, State Key Laboratory of Kidney Diseases, National Clinical Research Center for Kidney Diseases, Beijing Key Laboratory of Kidney Disease Research, Beijing, China
| | - Yuzhuo Zhao
- Department of Ultrasound, First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Jing Xiao
- Department of Ultrasound, First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Miao Li
- Department of Ultrasound, First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Ying Zhang
- Department of Ultrasound, First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Lianhua Zhu
- Department of Ultrasound, First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Yukun Luo
- The Second Medical College of Lanzhou University, Lanzhou, Gansu, China
- Department of Ultrasound, First Medical Center of Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
4
|
Liu N, Chen Y, Wang Y, Huang W, Zhan L, Du Z, Zhong Z, Wu Z, Shen Y, Deng X, Ni S, Tang L. A combination of ultrasound and contrast-enhanced ultrasound improves diagnostic accuracy for the differentiation of cervical tuberculous lymphadenitis from primary lymphoma. Clin Hemorheol Microcirc 2023; 85:261-275. [PMID: 37599529 DOI: 10.3233/ch-231876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/22/2023]
Abstract
OBJECTIVES To present a method combining ultrasound (US) and contrast-enhanced ultrasound (CEUS) features for differential diagnosis of cervical tuberculous lymphadenitis (CTL) and primary lymphoma. METHODS A total of 155 patients with CTL (n = 49) and lymphoma (n = 106) who underwent US and CEUS were retrospectively included. The features extracted from US and CEUS and the significant clinical data were created three models using the least absolute shrinkage and selection operator and logistic regression analysis. The diagnostic performance of the models was assessed using the area under the curve (AUC). RESULTS The combined model outperformed US model and CEUS model in distinguish CTL from lymphoma achieved favorable performances in training set and validation set with AUCs of 0.958 and 0.946 as well as high accuracies (91.7% and 87.2%), sensitivities (95.9% and 84.4%) and specificities (82.4% and 93.3%). Delong's test showed that among the three models, combined model was significantly different from the other two models in training set (p = 0.011 and 0.029, respectively) and validation set (p = 0.018 and 0.001, respectively). CONCLUSIONS A combination of US and CEUS achieved good diagnostic performance in differentiating lymphoma and CTL, which might aid in clinical decision-making.
Collapse
Affiliation(s)
- Naxiang Liu
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Yijie Chen
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Yaoqin Wang
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Weiqin Huang
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Lili Zhan
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Zhongshi Du
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Zhaoming Zhong
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Zhougui Wu
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Youhong Shen
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Xiaohong Deng
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Shixiong Ni
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| | - Lina Tang
- Department of Ultrasound, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
| |
Collapse
|
5
|
Wang T, Xu M, Xu C, Wu Y, Dong X. Comparison of microvascular flow imaging and contrast-enhanced ultrasound for blood flow analysis of cervical lymph node lesions. Clin Hemorheol Microcirc 2023; 85:249-259. [PMID: 37694358 DOI: 10.3233/ch-231860] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/12/2023]
Abstract
OBJECTIVE To compare the diagnostic value of microvascular flow imaging (MVFI) with that of contrast-enhanced ultrasound (CEUS) for the analysis of blood flow in benign and malignant cervical lymph nodes. MATERIAL AND METHODS As a prospective study, 95 cervical enlarged lymph nodes (43 benign and 52 malignant) were observed in 95 patients using conventional ultrasonography (including gray and Color Doppler Flow Imaging), CEUS, and MVFI. Two researchers evaluated vascular parameters of MVFI (vascular distribution, internal vascular features, vascular index) and CEUS (enhancement mode, enhancement type) and compared the diagnostic effects of MVFI and CEUS.All results were compared with pathological findings. RESULTS There were significant differences in the vascular distribution and internal vascular features of benign and malignant lymph nodes on MVFI (P < 0.05). The vascular distribution of benign lymph nodes was mainly of the central and avascular types, the internal blood vessels were mostly normal, the vascular distribution of malignant lymph nodes was mainly mixed, the internal vessels were mainly tortuous and displaced. The optimal cut-off value of the benign and malignant lymph node vascular index (VI) was 15.55%, and the area under the receiver operating characteristic curve (AUC) of the VI was 0.876. There were also significant differences in the enhancement mode and types of benign and malignant lymph nodes in CEUS (P < 0.05). The benign lymph nodes showed centrifugal perfusion, and the enhancement types were mostly type I and type II. Most malignant lymph nodes showed centripetal or mixed perfusion, and the enhancement types were usually type III and type IV. The accuracy, sensitivity, and specificity of CEUS in the diagnosis of lymph node lesions were 84.2%, 84.6% and 83.7%, respectively, and the AUC was 0.845. The accuracy, sensitivity, and specificity of MVFI in the diagnosis of lymph node lesions were 85.3%, 84.6%, and 86.0%, respectively, and the AUC was 0.886. CONCLUSION Both CEUS and MVFI are valuable in differentiating benign and malignant lesions of lymph nodes and have a similar diagnostic performance; however, MVFI is less invasive and simpler than CEUS. Therefore it is preferred for auxiliary examination of enlarged lymph nodes that are difficult to diagnose by conventional ultrasound.
Collapse
Affiliation(s)
- Tianqi Wang
- Department of Medical Ultrasound, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China
| | - Mingda Xu
- Department of Medical Ultrasound, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China
| | - Changyu Xu
- Department of Medical Ultrasound, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China
| | - Yuqing Wu
- Department of Medical Ultrasound, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China
| | - Xiaoqiu Dong
- Department of Medical Ultrasound, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China
| |
Collapse
|
6
|
Jung EM, Moran VO, Engel M, Krüger-Genge A, Stroszczynski C, Jung F. Modified contrast-enhanced ultrasonography with the new high-resolution examination technique of high frame rate contrast-enhanced ultrasound (HiFR-CEUS) for characterization of liver lesions: First results. Clin Hemorheol Microcirc 2023; 83:31-46. [PMID: 35466932 PMCID: PMC9986702 DOI: 10.3233/ch-221449] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIM To examine to what extent the high frame rate contrast-enhanced ultrasound (HiFR) diagnostic enables the conclusive diagnosis of liver changes with suspected malignancy. MATERIAL/METHODS Ultrasound examinations were performed by an experienced examiner using a multifrequency probe (SC6-1) on a high-end ultrasound system (Resona 7, Mindray) to clarify liver changes that were unclear on the B-scan. A bolus of 1-2.4 ml of the Sulphur hexafluoride ultrasound microbubbles contrast agent SonoVue™ (Bracco SpA, Italy) was administered with DICOM storage of CEUS examinations from the early arterial phase (5-15 s) to the late phase (5-6 min). Based on the image files stored in the PACS, an independent reading was performed regarding image quality and finding-related diagnostic significance (0 not informative/non-diagnostic to 5 excellent image quality/confident diagnosis possible). References were clinical follow-up, if possible, comparison to promptly performed computed tomography or magnetic resonance imaging, in some cases also to histopathology. RESULTS We examined 100 patients (42 women, 58 men, from 18 years to 90 years, mean 63±13 years) with different entities of focal and diffuse liver parenchymal changes, which could be detected in all cases with sufficient image quality with CEUS and with high image quality with HiFR-CEUS. Proportionally septate cysts were found in n = 19 cases, scars after hemihepatectomy with local reduced fat in n = 5 cases, scars after microwave ablation in n = 19 cases, hemangiomas in n = 9 cases, focal nodular hyperplasia in n = 8 cases, colorectal metastases in n = 15 cases, hepatocellular carcinoma (HCC) in n = 11 cases, Osler disease in n = 8 cases. The size of lesions ranged from 5 mm to 200 mm with a mean value of 33.1±27.8 mm. Conclusive diagnoses could be made by the experienced investigator in 97/100 cases with CEUS, confirmed by reference imaging, in parts by histopathology or follow-up. The image quality for HiFR CEUS was rated with a score of 3 to 5; 62 cases were assessed with an average of good (4 points), 27 cases with very good (5 points), and in 11 cases (3 points) still satisfactory despite aggravated acoustic conditions. The specificity of HIFR-CEUS was 97%, the sensitivity 97%, the positive predictive value 94%, the negative predictive value 99% and the accuracy 97%. CONCLUSION HIFR-CEUS has demonstrated has demonstrated an improved image quality resulting in a high diagnostic accuracy. In the hands of an experienced investigator, HiFR-CEUS allows the assessment of focal and diffuse unclear liver parenchymal changes on B-scan and dynamic assessment of microcirculation in solid and vascular changes.
Collapse
Affiliation(s)
- Ernst Michael Jung
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Valentina Ocaña Moran
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Martin Engel
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Anne Krüger-Genge
- Department of Healthcare, Biomaterials and Cosmeceuticals, Fraunhofer-Institute for Applied Polymer Research, Potsdam-Golm, Germany
| | - Christian Stroszczynski
- Institute of Diagnostic Radiology, Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
| | - Friedrich Jung
- Institute of Biotechnology, Molecular Cell Biology, Brandenburg University of Technology, Senftenberg, Germany
| |
Collapse
|
7
|
Huang X, Nie F, Zhu J, Liu L, Wang N. Application value of shear-wave elastography combined with monochrome superb microvascular imaging in renal allograft chronic rejection. Clin Hemorheol Microcirc 2022; 82:303-311. [PMID: 36057814 DOI: 10.3233/ch-221443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND Conventional ultrasound (US), which include gray scale US and Doppler US, is the first-line imaging modality for the evaluation of renal allograft; however, conventional US indicators have limitations. OBJECTIVE To explore the application value of shear-wave elastography (SWE) combined with monochrome superb microvascular imaging (mSMI) in renal allograft chronic rejection (CR). METHODS From November 2021 to February 2022 in the Lanzhou University Second Hospital, the US features of 54 patients with renal allograft were retrospectively analyzed. Patients were categorized into two groups: stable group(n = 44) and CR group(n = 10), with clinical diagnosis as reference standard. The vascular index (VI) on mSMI and parenchymal stiffness were measured in the middle cortex of all renal allografts and receiver operating characteristic (ROC) curves were drawn to evaluate the feasibility of differentiation. Statistically significant US features and biochemical indicators such as creatinine were scored, and the results of the scores were analyzed by ROC curve. RESULTS The VI on mSMI of the stable group (49.5±2.0) was significantly greater than that of the CR group (33.8±5.9) (P = 0.028). There was a statistically significant difference in parenchymal stiffness between stable group (16.2kPa±1.2) and CR group (33.9kPa±6.6) (P = 0.027). The sensitivity was 90% and specificity was 81.8% of the scores in the differentiation of stable group from CR group (cut-off value, 2; P = 0.000). CONCLUSION SWE combined with mSMI may help differentiate stable renal allograft from renal allograft CR and have the potential application value in the diagnosis of renal allograft CR.
Collapse
Affiliation(s)
- Xiao Huang
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Fang Nie
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Ju Zhu
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Luping Liu
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| | - Nan Wang
- Ultrasound Medical Center, Lanzhou University Second Hospital, Cuiyingmen, Chengguan District, Lanzhou, China.,Gansu Province Clinical Research Center for Ultrasonography, Lanzhou, China
| |
Collapse
|
8
|
Li JX, Li XL, Yu SY, Xu HX. Repeated ultrasound-guided percutaneous thermal ablation combined with systemic therapy achieves a stable condition in an end-stage patient with more than 10 liver metastases from breast cancer: The importance of sonazoid assisted contrast-enhanced ultrasound and fusion imaging. Clin Hemorheol Microcirc 2022; 82:85-93. [PMID: 35662111 DOI: 10.3233/ch-221413] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The liver is one of the most frequent metastatic sites of breast cancer with a relatively poor prognosis. Systemic chemotherapy is an effective treatment but the efficacy is different between the subtypes of breast cancer. Percutaneous thermal ablation is considered to be a minimally invasive and effective local treatment for breast cancer liver metastases (BCLM). This case report described a patient with BCLM who adopted a strategy of systemic chemotherapy and repeated ultrasound (US) -guided percutaneous thermal ablation procedures. The survival time already reached 8 years till now with the metastases well-controlled and acceptable life quality was achieved.
Collapse
Affiliation(s)
- Jia-Xin Li
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People's Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Xiao-Long Li
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People's Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Song-Yuan Yu
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People's Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Hui-Xiong Xu
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People's Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
- Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China
| |
Collapse
|