1
|
Use of Cardio-Pulmonary Ultrasound in the Neonatal Intensive Care Unit. CHILDREN 2023; 10:children10030462. [PMID: 36980020 PMCID: PMC10047372 DOI: 10.3390/children10030462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/11/2023] [Accepted: 02/22/2023] [Indexed: 03/03/2023]
Abstract
Cardiopulmonary ultrasound (CPUS), the combination of lung ultrasound (LUS) and targeted neonatal echocardiography (TnECHO)AA, may offer a more appropriate approach to the challenging neonatal cardiovascular and respiratory disorders. This paper reviews the possible use of CPUS in the neonatal intensive care unit (NICU).
Collapse
|
2
|
Cardiopulmonary Ultrasound Patterns of Transient Acute Respiratory Distress of the Newborn: A Retrospective Pilot Study. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10020289. [PMID: 36832418 PMCID: PMC9955778 DOI: 10.3390/children10020289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 01/20/2023] [Accepted: 01/28/2023] [Indexed: 02/05/2023]
Abstract
Acute transient respiratory distress in the first hours of life is usually defined as transient tachypnea of the newborn (TTN). TTN is a respiratory self-limiting disorder consequent to delayed lung fluid clearance at birth. While TTN is the most common etiology of respiratory distress near term, its pathogenesis and diagnostic criteria are not well-defined. Lung ultrasound and targeted neonatal echocardiography are increasingly being used to assess critically ill infants, although their combined use to improve diagnostic precision in neonatal intensive care units has not yet been described. This retrospective pilot analysis aimed to identify possible cardiopulmonary ultrasound (CPUS) patterns in term and late preterm infants suffering from transient respiratory distress and requiring non-invasive respiratory support. After retrospectively revising CPUS images, we found seven potential sonographic phenotypes of acute neonatal respiratory distress. Up to 50% of the patients presented with signs of increased pulmonary vascular resistance, suggesting that those patients may be diagnosed with mild forms of persistent pulmonary hypertension of the newborn. Approximately 80% of the infants with a history of meconium-stained amniotic fluid displayed irregular atelectasis, indicating that they may have suffered from mild meconium aspiration syndrome. CPUS evaluation may improve accuracy in the approach to the infants presenting with transient acute respiratory distress, supporting communication with the parents and carrying important epidemiological consequences.
Collapse
|
3
|
Chioma R, Amabili L, Ciarmoli E, Copetti R, Villani PG, Natile M, Vento G, Storti E, Pierro M. Lung UltraSound Targeted Recruitment (LUSTR): A Novel Protocol to Optimize Open Lung Ventilation in Critically Ill Neonates. CHILDREN (BASEL, SWITZERLAND) 2022; 9:children9071035. [PMID: 35884018 PMCID: PMC9317513 DOI: 10.3390/children9071035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 07/06/2022] [Accepted: 07/09/2022] [Indexed: 12/12/2022]
Abstract
This study investigated the effectiveness of an original Lung UltraSound Targeted Recruitment (LUSTR) protocol to improve the success of lung recruitment maneuvers (LRMs), which are performed as a rescue approach in critically ill neonates. All the LUSTR maneuvers, performed on infants with an oxygen saturation/fraction of inspired oxygen (S/F) ratio below 200, were included in this case−control study (LUSTR-group). The LUSTR-group was matched by the initial S/F ratio and underlying respiratory disease with a control group of lung recruitments performed following the standard oxygenation-guided procedure (Ox-group). The primary outcome was the improvement of the S/F ratio (Delta S/F) throughout the LRM. Secondary outcomes included the rate of air leaks. Each group was comprised of fourteen LRMs. As compared to the standard approach, the LUSTR protocol was associated with a higher success of the procedure in terms of Delta S/F (110 ± 47.3 vs. 64.1 ± 54.6, p = 0.02). This result remained significant after adjusting for confounding variables through multiple linear regressions. The incidence of pneumothorax was lower, although not reaching statistical significance, in the LUSTR-group (0 vs. 14.3%, p = 0.15). The LUSTR protocol may be a more effective and safer option than the oxygenation-based procedure to guide open lung ventilation in neonates, potentially improving ventilation and reducing the impact of ventilator-induced lung injury.
Collapse
Affiliation(s)
- Roberto Chioma
- Dipartimento Universitario Scienze della Vita e Sanità Pubblica, Unità Operativa Complessa di Neonatologia, Fondazione Policlinico Universitario A Gemelli Istituto di Ricovero e Cura a Carattere Scientifico, Università Cattolica del Sacro Cuore, 00168 Rome, Italy; (R.C.); (G.V.)
| | - Lorenzo Amabili
- Bernoulli Institute for Mathematics, Computer Science and Artificial Intelligence, University of Groningen, 9712 CP Groningen, The Netherlands;
| | - Elena Ciarmoli
- Department of Pediatrics, ASST Vimercate, Vimercate Hospital, 20871 Vimercate, Italy;
| | - Roberto Copetti
- Emergency Department, Latisana General Hospital, 33053 Udine, Italy;
| | - Pier Giorgio Villani
- Department of Critical Care, Maggiore Hospital, 26100 Cremona, Italy; (P.G.V.); (E.S.)
| | - Miria Natile
- Neonatal Intensive Care Unit, Azienda Sanitaria Romagna, Infermi Hospital Rimini, 47923 Rimini, Italy;
| | - Giovanni Vento
- Dipartimento Universitario Scienze della Vita e Sanità Pubblica, Unità Operativa Complessa di Neonatologia, Fondazione Policlinico Universitario A Gemelli Istituto di Ricovero e Cura a Carattere Scientifico, Università Cattolica del Sacro Cuore, 00168 Rome, Italy; (R.C.); (G.V.)
| | - Enrico Storti
- Department of Critical Care, Maggiore Hospital, 26100 Cremona, Italy; (P.G.V.); (E.S.)
| | - Maria Pierro
- Neonatal and Paediatric Intensive Care Unit, M. Bufalini Hospital, AUSL Romagna, 47521 Cesena, Italy
- Correspondence: ; Tel.: +39-0547352844
| |
Collapse
|
4
|
Bruno G, Chioma R, Storti E, De Luca G, Fantinato M, Antonazzo P, Pierro M. Targeted management of evolving and established chronic lung disease of prematurity assisted by cardiopulmonary ultrasound: A case report of four patients. Front Pediatr 2022; 10:1112313. [PMID: 36793502 PMCID: PMC9922992 DOI: 10.3389/fped.2022.1112313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 12/22/2022] [Indexed: 01/31/2023] Open
Abstract
Bronchopulmonary dysplasia (BPD) is one of the most common complications of premature birth. The current definition of BPD is based on the duration of oxygen therapy and/or respiratory support. Among the pitfalls of all the diagnostic definitions, the lack of a proper pathophysiologic classification makes it difficult to choose an appropriate drug strategy for BPD. In this case report, we describe the clinical course of four premature infants, admitted to the neonatal intensive care unit, for whom the use of lung and cardiac ultrasound was an integral part of the diagnostic and therapeutic process. We describe, for the first time to our knowledge, four different cardiopulmonary ultrasound patterns of evolving and established chronic lung disease of prematurity and the consequent therapeutic choices. This approach, if confirmed in prospective studies, may guide the personalized management of infants suffering from evolving and established BPD, optimizing the chances of success of the therapies and at the same time reducing the risk of exposure to inadequate and potentially harmful drugs.
Collapse
Affiliation(s)
- Guglielmo Bruno
- Neonatal and Paediatric Intensive Care Unit, M. Bufalini Hospital, AUSL Romagna, Cesena, Italy.,Paediatric Unit, Azienda Ospedaliero-Universitaria di Ferrara, Ferrara, Italy
| | - Roberto Chioma
- Dipartimento Universitario Scienze Della Vita e Sanità Pubblica, Unità Operativa Complessa di Neonatologia, Fondazione Policlinico Universitario A. Gemelli Istituto di Ricovero e Cura a Carattere Scientifico, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Enrico Storti
- Department of Critical Care, Maggiore Hospital, Cremona, Cremona, Italy
| | - Giovanni De Luca
- Pathologic Anatomy Oncohematology Department, M. Bufalini Hospital, AUSL Romagna, Cesena, Italy
| | - Margherita Fantinato
- Neonatal and Paediatric Intensive Care Unit, M. Bufalini Hospital, AUSL Romagna, Cesena, Italy
| | - Patrizio Antonazzo
- Unit of Obstetrics and Gynecology, Bufalini Hospital-AUSL Romagna, Cesena, Italy
| | - Maria Pierro
- Neonatal and Paediatric Intensive Care Unit, M. Bufalini Hospital, AUSL Romagna, Cesena, Italy
| |
Collapse
|
5
|
Wang J, Wei H, Chen H, Wan K, Mao R, Xiao P, Chang X. Application of ultrasonography in neonatal lung disease: An updated review. Front Pediatr 2022; 10:1020437. [PMID: 36389379 PMCID: PMC9640768 DOI: 10.3389/fped.2022.1020437] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 09/27/2022] [Indexed: 11/26/2022] Open
Abstract
Lung disease is often life-threatening for both preterm and term newborns. Therefore, an accurate and rapid diagnosis of lung diseases in newborns is crucial, as management strategies differ with different etiologies. To reduce the risk of radiation exposure derived from the conventionally used chest x-ray as well as computed tomography scans, lung ultrasonography (LUS) has been introduced in clinical practice to identify and differentiate neonatal lung diseases because of its radiation-free characteristic, convenience, high accuracy, and low cost. In recent years, it has been proved that LUS exhibits high sensitivity and specificity for identifying various neonatal lung diseases. Here, we offer an updated review of the applications of LUS in neonatal lung diseases based on the reports published in recent years (2017 to present).
Collapse
Affiliation(s)
- Jin Wang
- Department of Ultrasound Medicine, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| | - Hongjuan Wei
- Department of Neonatology, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| | - Hui Chen
- Department of Ultrasound Medicine, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| | - Ke Wan
- School of Medical Sciences, University of Sydney, Sydney, New South Wales, Australia
| | - Ruifeng Mao
- School of Life Sciences, Huaiyin Normal University, Huai'an, China
| | - Peng Xiao
- Department of Dermatology, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| | - Xin Chang
- Department of Ultrasound Medicine, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| |
Collapse
|