1
|
Transcranial alternating current stimulation combined with sound stimulation improves cognitive function in patients with Alzheimer's disease: Study protocol for a randomized controlled trial. Front Aging Neurosci 2023; 14:1068175. [PMID: 36698862 PMCID: PMC9869764 DOI: 10.3389/fnagi.2022.1068175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 12/14/2022] [Indexed: 01/12/2023] Open
Abstract
Background The number of patients with Alzheimer's disease (AD) worldwide is increasing yearly, but the existing treatment methods have poor efficacy. Transcranial alternating current stimulation (tACS) is a new treatment for AD, but the offline effect of tACS is insufficient. To prolong the offline effect, we designed to combine tACS with sound stimulation to maintain the long-term post-effect. Materials and methods To explore the safety and effectiveness of tACS combined with sound stimulation and its impact on the cognition of AD patients. This trial will recruit 87 patients with mild to moderate AD. All patients were randomly divided into three groups. The change in Alzheimer's Disease Assessment Scale-Cognitive (ADAS-Cog) scores from the day before treatment to the end of treatment and 3 months after treatment was used as the main evaluation index. We will also explore the changes in the brain structural network, functional network, and metabolic network of AD patients in each group after treatment. Discussion We hope to conclude that tACS combined with sound stimulation is safe and tolerable in 87 patients with mild to moderate AD under three standardized treatment regimens. Compared with tACS alone or sound alone, the combination group had a significant long-term effect on cognitive improvement. To screen out a better treatment plan for AD patients. tACS combined with sound stimulation is a previously unexplored, non-invasive joint intervention to improve patients' cognitive status. This study may also identify the potential mechanism of tACS combined with sound stimulation in treating mild to moderate AD patients. Clinical Trial Registration Clinicaltrials.gov, NCT05251649. Registered on February 22, 2022.
Collapse
|
2
|
Adjunctive transcranial alternating current stimulation for patients with major depressive disorder: A systematic review and meta-analysis. Front Psychiatry 2023; 14:1154354. [PMID: 37032914 PMCID: PMC10073427 DOI: 10.3389/fpsyt.2023.1154354] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 03/06/2023] [Indexed: 04/11/2023] Open
Abstract
Objective We performed a meta-analysis of randomized, double-blind, controlled trials (RCTs) to systematically investigate the therapeutic effects and tolerability of transcranial alternating current stimulation (tACS) for the treatment of patients with major depressive disorder (MDD). Methods Electronic search of PubMed, PsycINFO, EMBASE, Chinese National Knowledge Infrastructure, Wanfang database, and the Cochrane Library up to 1 April 2022. Double-blind RCTs examining the efficacy and safety of tACS for patients with MDD were included. The primary outcome was the improvement of depressive symptoms following a course of tACS treatment. Data were analyzed using Review Manager Version 5.3 (Cochrane IMS, Oxford, UK). Study quality was assessed using the Cochrane risk of bias and Jadad scale. Publication bias was assessed using a funnel plot and the Egger test. Results We identified 883 articles, of which 4 RCTs with 5 active treatment arms covering 224 participants with MDD on active tACS (n = 117) and sham tACS (n = 107) were eligible for inclusion. Meta-analysis of depressive symptoms at post-tACS found an advantage of active tACS over sham tACS (n = 212, standard mean difference (SMD) = -1.14, 95% confidence interval (CI): -2.23, -0.06; I 2 = 90%, P = 0.04). The significant superiority of active tACS over sham tACS in improving depressive symptoms remained in a sensitivity analysis. Active tACS was significantly superior to sham tACS regarding depressive symptoms at the 4 week follow-up (SMD = -1.07, 95% CI: -2.05, -0.08; I 2 = 88%, P = 0.03) and study-defined remission [risk ratio (RR) = 2.07, 95% CI: 1.36, 3.14, I 2 = 9%, P = 0.0006]. The discontinuation rate due to any reason was similar between the two groups (P > 0.05). All included studies were rated as high quality (Jadad score ≥ 3), with funnel plots of primary outcome not suggestive of publication bias. Conclusion tACS appeared to be modestly effective and safe for improving depressive symptoms in patients with MDD, although further studies are warranted.
Collapse
|
3
|
Amplitude modulating frequency overrides carrier frequency in tACS-induced phosphene percept. Hum Brain Mapp 2022; 44:914-926. [PMID: 36250439 PMCID: PMC9875935 DOI: 10.1002/hbm.26111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 09/24/2022] [Accepted: 10/03/2022] [Indexed: 01/28/2023] Open
Abstract
The amplitude modulated (AM) neural oscillation is an essential feature of neural dynamics to coordinate distant brain areas. The AM transcranial alternating current stimulation (tACS) has recently been adopted to examine various cognitive functions, but its neural mechanism remains unclear. The current study utilized the phosphene phenomenon to investigate whether, in an AM-tACS, the AM frequency could modulate or even override the carrier frequency in phosphene percept. We measured the phosphene threshold and the perceived flash rate/pattern from 12 human subjects (four females, aged from 20-44 years old) under tACS that paired carrier waves (10, 14, 18, 22 Hz) with different envelope conditions (0, 2, 4 Hz) over the mid-occipital and left facial areas. We also examined the phosphene source by adopting a high-density stimulation montage. Our results revealed that (1) phosphene threshold was higher for AM-tACS than sinusoidal tACS and demonstrated different carrier frequency functions in two stimulation montages. (2) AM-tACS slowed down the phosphene flashing and abolished the relation between the carrier frequency and flash percept in sinusoidal tACS. This effect was independent of the intensity change of the stimulation. (3) Left facial stimulation elicited phosphene in the upper-left visual field, while occipital stimulation elicited equally distributed phosphene. (4) The near-eye electrodermal activity (EDA) measured under the threshold-level occipital tACS was greater than the lowest power sufficient to elicit retinal phosphene. Our results show that AM frequency may override the carrier frequency and determine the perceived flashing frequency of AM-tACS-induced phosphene.
Collapse
|
4
|
Phosphene Attributes Depend on Frequency and Intensity of Retinal tACS. Physiol Res 2022. [DOI: 10.33549/physiolres.934887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Phosphene is the experience of light without natural visual stimulation. It can be induced by electrical stimulation of the retina, optic nerve or cortex. Induction of phosphenes can be potentially used in assistive devices for the blind. Analysis of phosphene might be beneficial for practical reasons such as adjustment of transcranial alternating current stimulation (tACS) frequency and intensity to eliminate phosphene perception (e.g., tACS studies using verum tACS group and sham group) or, on the contrary, to maximize perception of phosphenes in order to be more able to study their dynamics. In this study, subjective reports of 50 healthy subjects exposed to different intensities of retinal tACS at 4 different frequencies (6, 10, 20 and 40 Hz) were analyzed. The effectiveness of different tACS frequencies in inducing phosphenes was at least 92 %. Subject reported 41 different phosphene types; the most common were light flashes and light circles. Changing the intensity of stimulation often induced a change in phosphene attributes. Up to nine phosphene attributes changed when the tACS intensity was changed. Significant positive correlation was observed between number of a different phosphene types and tACS frequency. Based on these findings, it can be concluded that tACS is effective in eliciting phosphenes whose type and attributes change depending on the frequency and intensity of tACS. The presented results open new questions for future research.
Collapse
|
5
|
Local and Distributed fMRI Changes Induced by 40 Hz Gamma tACS of the Bilateral Dorsolateral Prefrontal Cortex: A Pilot Study. Neural Plast 2022; 2022:6197505. [PMID: 35880231 PMCID: PMC9308536 DOI: 10.1155/2022/6197505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 05/06/2022] [Accepted: 06/21/2022] [Indexed: 11/18/2022] Open
Abstract
Over the past few years, the possibility of modulating fast brain oscillatory activity in the gamma (γ) band through transcranial alternating current stimulation (tACS) has been discussed in the context of both cognitive enhancement and therapeutic scenarios. However, the effects of tACS targeting regions outside the motor cortex, as well as its spatial specificity, are still unclear. Here, we present a concurrent tACS-fMRI block design study to characterize the impact of 40 Hz tACS applied over the left and right dorsolateral prefrontal cortex (DLPFC) in healthy subjects. Results suggest an increase in blood oxygenation level-dependent (BOLD) activity in the targeted bilateral DLPFCs, as well as in surrounding brain areas affected by stimulation according to biophysical modeling, i.e., the premotor cortex and anterior cingulate cortex (ACC). However, off-target effects were also observed, primarily involving the visual cortices, with further effects on the supplementary motor areas (SMA), left subgenual cingulate, and right superior temporal gyrus. The specificity of 40 Hz tACS over bilateral DLPFC and the possibility for network-level effects should be considered in future studies, especially in the context of recently promoted gamma-induction therapeutic protocols for neurodegenerative disorders.
Collapse
|
6
|
Benchmarking the Effects of Transcranial Temporal Interference Stimulation (tTIS) in Humans. Cortex 2022; 154:299-310. [DOI: 10.1016/j.cortex.2022.05.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 03/07/2022] [Accepted: 05/23/2022] [Indexed: 11/03/2022]
|
7
|
Optimizing the Montage for Cerebellar Transcranial Alternating Current Stimulation (tACS): a Combined Computational and Experimental Study. J Neural Eng 2022; 19. [PMID: 35421852 DOI: 10.1088/1741-2552/ac676f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 04/13/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE The application of cerebellar transcranial alternating current stimulation (tACS) is limited by the absence of commonly agreed montages and also the presence of unpleasant side effects. We aimed to find the most effective cerebellar tACS montage with minimum side effects (skin sensations and phosphenes). APPROACH We first simulated cerebellar tACS with five montages (return electrode on forehead, buccinator, jaw, and neck positions, additionally focal montage with high-definition ring electrodes) to compare induced cerebellar current, then stimulated healthy participants and evaluated side effects for different montages and varying stimulation frequencies. MAIN RESULTS The simulation revealed a descending order of current density in the cerebellum from forehead to buccinator, jaw, neck and ring montage respectively. Montages inducing higher current intensity in the eyeballs during the simulation resulted in stronger and broader phosphenes during tACS sessions. Strong co-stimulation of the brainstem was observed for the neck. Skin sensations did not differ between montages or frequencies. We propose the jaw montage as an optimal choice for maximizing cerebellar stimulation while minimizing unwanted side effects. SIGNIFICANCE These findings contribute to adopting a standard cerebellar tACS protocol. The combination of computational modelling and experimental data offers improved experimental control, safety, effectiveness, and reproducibility to all brain stimulation practices.
Collapse
|
8
|
A checklist for assessing the methodological quality of concurrent tES-fMRI studies (ContES checklist): a consensus study and statement. Nat Protoc 2022; 17:596-617. [PMID: 35121855 PMCID: PMC7612687 DOI: 10.1038/s41596-021-00664-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Accepted: 11/12/2021] [Indexed: 11/09/2022]
Abstract
Low-intensity transcranial electrical stimulation (tES), including alternating or direct current stimulation, applies weak electrical stimulation to modulate the activity of brain circuits. Integration of tES with concurrent functional MRI (fMRI) allows for the mapping of neural activity during neuromodulation, supporting causal studies of both brain function and tES effects. Methodological aspects of tES-fMRI studies underpin the results, and reporting them in appropriate detail is required for reproducibility and interpretability. Despite the growing number of published reports, there are no consensus-based checklists for disclosing methodological details of concurrent tES-fMRI studies. The objective of this work was to develop a consensus-based checklist of reporting standards for concurrent tES-fMRI studies to support methodological rigor, transparency and reproducibility (ContES checklist). A two-phase Delphi consensus process was conducted by a steering committee (SC) of 13 members and 49 expert panelists through the International Network of the tES-fMRI Consortium. The process began with a circulation of a preliminary checklist of essential items and additional recommendations, developed by the SC on the basis of a systematic review of 57 concurrent tES-fMRI studies. Contributors were then invited to suggest revisions or additions to the initial checklist. After the revision phase, contributors rated the importance of the 17 essential items and 42 additional recommendations in the final checklist. The state of methodological transparency within the 57 reviewed concurrent tES-fMRI studies was then assessed by using the checklist. Experts refined the checklist through the revision and rating phases, leading to a checklist with three categories of essential items and additional recommendations: (i) technological factors, (ii) safety and noise tests and (iii) methodological factors. The level of reporting of checklist items varied among the 57 concurrent tES-fMRI papers, ranging from 24% to 76%. On average, 53% of checklist items were reported in a given article. In conclusion, use of the ContES checklist is expected to enhance the methodological reporting quality of future concurrent tES-fMRI studies and increase methodological transparency and reproducibility.
Collapse
|
9
|
Amplitude modulated transcranial alternating current stimulation (AM-TACS) efficacy evaluation via phosphene induction. Sci Rep 2021; 11:22245. [PMID: 34782626 PMCID: PMC8593032 DOI: 10.1038/s41598-021-01482-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Accepted: 10/18/2021] [Indexed: 12/01/2022] Open
Abstract
Amplitude modulated transcranial alternating current stimulation (AM-tACS) is a novel method of electrostimulation which enables the recording of electrophysiological signals during stimulation, thanks to an easier removable stimulation artefact compared to classical electrostimulation methods. To gauge the neuromodulatory potential of AM-tACS, we tested its capacity to induce phosphenes as an indicator of stimulation efficacy. AM-tACS was applied via a two-electrode setup, attached on FpZ and below the right eye. AM-tACS waveforms comprised of different carrier (50 Hz, 200 Hz, 1000 Hz) and modulation frequencies (8 Hz, 16 Hz, 28 Hz) were administered with at maximum 2 mA peak-to-peak stimulation strength. TACS conditions in the same frequencies were used as a benchmark for phosphene induction. AM-tACS conditions using a 50 Hz carrier frequency were able to induce phosphenes, but with no difference in phosphene thresholds between modulation frequencies. AM-tACS using a 200 Hz or 1000 Hz carrier frequency did not induce phosphenes. TACS conditions induced phosphenes in line with previous studies. Stimulation effects of AM-tACS conditions were independent of amplitude modulation and instead relied solely on the carrier frequency. A possible explanation may be that AM-tACS needs higher stimulation intensities for its amplitude modulation to have a neuromodulatory effect.
Collapse
|
10
|
Evaluating Current Density Modeling of Non-Invasive Eye and Brain Electrical Stimulation Using Phosphene Thresholds. IEEE Trans Neural Syst Rehabil Eng 2021; 29:2133-2141. [PMID: 34648453 PMCID: PMC8594910 DOI: 10.1109/tnsre.2021.3120148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Because current flow cannot be measured directly in the intact retina or brain, current density distribution models were developed to estimate it during magnetic or electrical stimulation. A paradigm is now needed to evaluate if current flow modeling can be related to physiologically meaningful signs of true current distribution in the human brain. We used phosphene threshold measurements (PTs) as surrogate markers of current-flow to determine if PTs, evoked by transcranial alternating current stimulation (tACS), can be matched with current density estimates generated by head model-based computer simulations. Healthy, male subjects (n=15) were subjected to three-staged PT measurements comparing six unilateral and one bilateral stimulation electrode montages according to the 10/20 system: Fp2-Suborbital right (So), Fp2-right shoulder (rS), Fp2-Cz, Fp2- O2, So-rS, Cz-F8 and F7-F8. The stimulation frequency was set at 16 Hz. Subjects were asked to report the appearance and localization of phosphenes in their visual field for every montage. Current density models were built using multi-modal imaging data of a standard brain, meshed with isotropic conductivities of different tissues of the head using the SimBio and SCIRun software packages. We observed that lower PTs were associated with higher simulated current levels in the unilateral montages of the model head, and shorter electrode distances to the eye had lower PTs. The lowest mean PT and the lowest variability were found in the F7-F8 montage (95±33 μA). Our results confirm the hypothesis that phosphenes are primarily of retinal origin, and they provide the first in vivo evidence that computer models of current flow using head models are a valid tool to estimate real current flow in the human eye and brain.
Collapse
|
11
|
Synaptic Effect of Aδ-Fibers by Pulse-Train Electrical Stimulation. Front Neurosci 2021; 15:643448. [PMID: 33981196 PMCID: PMC8107290 DOI: 10.3389/fnins.2021.643448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 03/29/2021] [Indexed: 11/17/2022] Open
Abstract
Electrical stimulation of specific small fibers (Aδ- and C-fibers) is used in basic studies on nociception and neuropathic pain and to diagnose neuropathies. For selective stimulation of small fibers, the optimal stimulation waveform parameters are an important aspect together with the study of electrode design. However, determining an optimal stimulation condition is challenging, as it requires the characterization of the response of the small fibers to electrical stimulation. The perception thresholds are generally characterized using single-pulse stimulation based on the strength-duration curve. However, this does not account for the temporal effects of the different waveforms used in practical applications. In this study, we designed an experiment to characterize the effects of multiple pulse stimulation and proposed a computational model that considers electrostimulation of fibers and synaptic effects in a multiscale model. The measurements of perception thresholds showed that the pulse dependency of the threshold was an exponential decay with a maximum reduction of 55%. In addition, the frequency dependence of the threshold showed a U-shaped response with a reduction of 25% at 30 Hz. Moreover, the computational model explained the synaptic effects, which were also confirmed by evoked potential recordings. This study further characterized the activation of small fibers and clarified the synaptic effects, demonstrating the importance of waveform selection.
Collapse
|
12
|
Addiction history moderates the effect of prefrontal 10-Hz transcranial alternating current stimulation on habitual action selection. J Neurophysiol 2021; 125:768-780. [PMID: 33356905 PMCID: PMC7988748 DOI: 10.1152/jn.00180.2020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 11/29/2020] [Accepted: 12/12/2020] [Indexed: 02/07/2023] Open
Abstract
Individuals with substance use disorders (SUDs) transition more quickly from goal-directed to habitual action-selection, but the neural mechanisms underlying this phenomenon remain unclear. Data from animal models suggest that drugs of abuse can modify the neurocircuits that regulate action-selection, enhancing circuits that drive inflexible, habit-based stimulus-response (S-R) action-selection and weakening circuits that drive flexible, goal-directed actions. Here, we tested the effect of bilateral 10-Hz transcranial alternating current stimulation (10Ηz-tACs) of the dorsolateral prefrontal cortex on action-selection in men and women with a SUD history and an age- and sex-matched control group. We tested the hypothesis that true 10Ηz-tACS versus active sham stimulation would reduce perseverative errors after changed response contingencies for well-learned S-R associations, reflecting reduced habit-based action-selection, specifically in the SUD group. We found that 10 Hz-tACS increased perseverative errors in the control group, but in the SUD group, 10 Hz-tACS effects on perseverative errors depended on substance abuse duration: a longer addiction history was associated with a greater reduction of perseverative errors. These results suggest that 10Ηz-tACs altered circuit level dynamics regulating behavioral flexibility, and provide a foundation for future studies to test stimulation site, frequency, and timing specificity. Moreover, these data suggest that chronic substance abuse is associated with altered circuit dynamics that are ameliorated by 10Ηz-tACs. Determining the generalizability of these effects and their duration merits investigation as a direction for novel therapeutic interventions. These findings are timely based on growing interest in transcranial stimulation methods for treating SUDs.NEW & NOTEWORTHY Treating the executive dysfunction associated with addiction is hampered by redundancies in pharmacological regulation of different behavioral control circuits. Thus, nonpharmacological interventions hold promise for addiction treatment. Here, we show that, among people with an addiction history, 10-Hz transcranial alternating current stimulation (10Hz-tACS) of the dorsolateral prefrontal cortex can reduce habitual actions. The fact that 10Hz-tACS can regulate behavioral flexibility suggests its possible utility in reducing harmful habitual actions.
Collapse
|
13
|
Transcranial alternating current stimulation (tACS): from basic mechanisms towards first applications in psychiatry. Eur Arch Psychiatry Clin Neurosci 2021; 271:135-156. [PMID: 33211157 PMCID: PMC7867505 DOI: 10.1007/s00406-020-01209-9] [Citation(s) in RCA: 90] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 10/27/2020] [Indexed: 12/11/2022]
Abstract
Transcranial alternating current stimulation (tACS) is a unique form of non-invasive brain stimulation. Sinusoidal alternating electric currents are delivered to the scalp to affect mostly cortical neurons. tACS is supposed to modulate brain function and, in turn, cognitive processes by entraining brain oscillations and inducing long-term synaptic plasticity. Therefore, tACS has been investigated in cognitive neuroscience, but only recently, it has been also introduced in psychiatric clinical trials. This review describes current concepts and first findings of applying tACS as a potential therapeutic tool in the field of psychiatry. The current understanding of its mechanisms of action is explained, bridging cellular neuronal activity and the brain network mechanism. Revisiting the relevance of altered brain oscillations found in six major psychiatric disorders, putative targets for the management of mental disorders using tACS are discussed. A systematic literature search on PubMed was conducted to report findings of the clinical studies applying tACS in patients with psychiatric conditions. In conclusion, the initial results may support the feasibility of tACS in clinical psychiatric populations without serious adverse events. Moreover, these results showed the ability of tACS to reset disturbed brain oscillations, and thus to improve behavioural outcomes. In addition to its potential therapeutic role, the reactivity of the brain circuits to tACS could serve as a possible tool to determine the diagnosis, classification or prognosis of psychiatric disorders. Future double-blind randomised controlled trials are necessary to answer currently unresolved questions. They may aim to detect response predictors and control for various confounding factors.
Collapse
|
14
|
The effects of a single-session cathodal transcranial pulsed current stimulation on corticospinal excitability: A randomized sham-controlled double-blinded study. Eur J Neurosci 2020; 52:4908-4922. [PMID: 33128480 DOI: 10.1111/ejn.14916] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 06/16/2020] [Accepted: 07/11/2020] [Indexed: 12/17/2022]
Abstract
Transcranial pulsed current stimulation (tPCS) of the human motor cortex has received much attention in recent years. Although the effect of anodal tPCS with different frequencies has been investigated, the effect of cathodal tPCS (c-tPCS) has not been explored yet. Therefore, the aim of the present study was to investigate the effect of c-tPCS at 4 and 75 Hz frequencies on corticospinal excitability (CSE) and motor performance. In a randomized sham-controlled crossover design, fifteen healthy participants attended three experimental sessions and received either c-tPCS at 75 Hz, 4 Hz or sham with 1.5 mA for 15 min. Transcranial magnetic stimulation and grooved pegboard test were performed before, immediately after and 30 min after the completion of stimulation at rest. The findings indicate that c-tPCS at both 4 and 75 Hz significantly increased CSE compared to sham. Both c-tPCS at 75 and 4 Hz showed a significant increase in intracortical facilitation compared to sham, whereas the effect on short-interval intracortical inhibition was not significant. The c-tPCS at 4 Hz but not 75 Hz induced modulation of intracortical facilitation correlated with the CSE. Motor performance did not show any significant changes. These results suggest that, compared with sham stimulation, c-tPCS at both 4 and 75 Hz induces an increase in CSE.
Collapse
|
15
|
θ-γ Cross-Frequency Transcranial Alternating Current Stimulation over the Trough Impairs Cognitive Control. eNeuro 2020; 7:ENEURO.0126-20.2020. [PMID: 32764077 PMCID: PMC7540931 DOI: 10.1523/eneuro.0126-20.2020] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Revised: 07/15/2020] [Accepted: 07/15/2020] [Indexed: 01/16/2023] Open
Abstract
Cognitive control is a mental process, which underlies adaptive goal-directed decisions. Previous studies have linked cognitive control to electrophysiological fluctuations in the θ band and θ-γ cross-frequency coupling (CFC) arising from the cingulate and frontal cortices. However, to date, the behavioral consequences of different forms of θ-γ CFC remain elusive. Here, we studied the behavioral effects of the θ-γ CFC via transcranial alternating current stimulation (tACS) designed to stimulate the frontal and cingulate cortices in humans. Using a double-blind, randomized, repeated measures study design, 24 healthy participants were subjected to three active and one control CFC-tACS conditions. In the active conditions, 80-Hz γ tACS was coupled to 4-Hz θ tACS. Specifically, in two of the active conditions, short γ bursts were coupled to the delivered θ cycle to coincide with either its peaks or troughs. In the third active condition, the phase of a θ cycle modulated the amplitude of the γ oscillation. In the fourth, control protocol, 80-Hz tACS was continuously superimposed over the 4-Hz tACS, therefore lacking any phase specificity in the CFC. During the 20 min of stimulation, the participants performed a Go/NoGo monetary reward-based and punishment-based instrumental learning task. A Bayesian hierarchical logistic regression analysis revealed that relative to the control, the peak-coupled tACS had no effects on the behavioral performance, whereas the trough-coupled tACS and, to a lesser extent, amplitude-modulated tACS reduced performance in conflicting trials. Our results suggest that cognitive control depends on the phase specificity of the θ-γ CFC.
Collapse
|
16
|
Transcranial Alternating Current Stimulation of the Primary Motor Cortex after Skill Acquisition Improves Motor Memory Retention in Humans: A Double-Blinded Sham-Controlled Study. Cereb Cortex Commun 2020; 1:tgaa047. [PMID: 34296115 PMCID: PMC8152838 DOI: 10.1093/texcom/tgaa047] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 07/24/2020] [Accepted: 07/24/2020] [Indexed: 12/19/2022] Open
Abstract
Consolidation leading to retention of motor memory following motor practice involves activity-dependent plastic processes in the corticospinal system. To investigate whether beta-band transcranial alternating current stimulation (tACS) applied immediately following skill acquisition can enhance ongoing consolidation processes and thereby motor skill retention 20 adults participated in a randomized, double-blinded, sham-controlled study. Participants received tACS at peak beta-band corticomuscular coherence (CMC) frequency or sham tACS for 10 min following practice of a visuomotor ankle dorsiflexion task. Performance was measured as the average percentage time on target. Electroencephalograhy (EMG) was measured at Cz and EMG from the right tibialis anterior muscle. CMC and intramuscular coherence (IMC) were estimated during 2-min tonic dorsiflexion. Motor skill retention was tested 1 and 7 days after motor practice. From the end of motor practice to the retention tests, motor performance improved more in the tACS group compared with the sham tACS group after 1 (P = 0.05) and 7 days (P < 0.001). At both retention tests, beta-band IMC increased in the tACS group compared with post-tACS. Beta-band CMC increased in the tACS group at retention day 1 compared with post-tACS. Changes in CMC but not IMC were correlated with performance 1 and 7 days following practice. This study shows that tACS applied at beta-band CMC frequency improves consolidation following visuomotor practice and increases beta-band CMC and IMC. We propose that oscillatory beta activity in the corticospinal system may facilitate consolidation of the motor skill.
Collapse
|
17
|
Abstract
AbstractSustained attention is defined as the ability to maintain attention over longer periods of time, which typically declines with time on task (i.e., the vigilance decrement). Previous studies have suggested an important role for the dorsomedial prefrontal cortex (mPFC) in sustained attention. In two experiments, we aimed to enhance sustained attention by applying transcranial electrical current stimulation over the mPFC during a sustained attention task. In the first experiment, we applied transcranial direct current stimulation (tDCS) in a between-subject design (n = 97): participants received either anodal, cathodal, or sham stimulation. Contrary to our prediction, we found no effect of stimulation on the vigilance decrement. In the second experiment, participants received theta and alpha transcranial alternating current stimulation (tACS) in two separate sessions (n = 47, within-subject design). Here, we found a frequency-dependent effect on the vigilance decrement, such that contrary to our expectation, participants’ performance over time became worse after theta compared with alpha stimulation. However, this result needs to be interpreted with caution given that this effect could be driven by differential side effects between the two stimulation frequencies. To conclude, across two studies, we were not able to reduce the vigilant decrement using tDCS or theta tACS.
Collapse
|
18
|
Detecting cortical circuits resonant to high-frequency oscillations in the human primary motor cortex: a TMS-tACS study. Sci Rep 2020; 10:7695. [PMID: 32376946 PMCID: PMC7203184 DOI: 10.1038/s41598-020-64717-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Accepted: 04/17/2020] [Indexed: 11/19/2022] Open
Abstract
Corticospinal volleys evoked by transcranial magnetic stimulation (TMS) over the primary motor cortex (M1) consist of high-frequency bursts (≈667 and ≈333 Hz). However, intracortical circuits producing such corticospinal high-frequency bursts are unknown. We here investigated whether neurons activated by single TMS pulses over M1 are resonant to high-frequency oscillations, using a combined transcranial alternating current stimulation (tACS)-TMS approach. We applied 667, 333 Hz or sham-tACS and, concurrently, we delivered six single-pulse TMS protocols using monophasic or biphasic pulses, different stimulation intensities, muscular states, types and orientations of coils. We recorded motor evoked potentials (MEPs) before, during and after tACS. 333 Hz tACS facilitated MEPs evoked by biphasic TMS through a figure-of-eight coil at active motor threshold (AMT), and by monophasic TMS with anterior-to-posterior-induced current in the brain. 333 Hz tACS also facilitated MEPs evoked by monophasic TMS through a circular coil at AMT, an effect that weakly persisted after the stimulation. 667 Hz tACS had no effects. 333 Hz, but not 667 Hz, tACS may have reinforced the synchronization of specific neurons to high-frequency oscillations enhancing this activity, and facilitating MEPs. Our findings suggest that different bursting modes of corticospinal neurons are produced by separate circuits with different oscillatory properties.
Collapse
|
19
|
Feasibility of Interferential and Pulsed Transcranial Electrical Stimulation for Neuromodulation at the Human Scale. Neuromodulation 2020; 24:843-853. [PMID: 32147953 DOI: 10.1111/ner.13137] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/06/2020] [Accepted: 02/13/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVES Transcranial electrical stimulation (tES) is a promising tool for modulating neural activity, but tES has poor penetrability and spatiotemporal resolution compared to invasive techniques like deep brain stimulation (DBS). Interferential strategies for alternating-current stimulation (IF-tACS) and pulsed/intersectional strategies for transcranial direct-current stimulation (IS-tDCS) address some of the limitations of tES, but the comparative advantages and disadvantages of these new techniques is not well understood. This study's objective was to evaluate the suprathreshold and subthreshold membrane dynamics of neurons in response to IF-tACS and IS-tDCS. MATERIALS AND METHODS We analyzed the biophysics of IF-tACS and IS-tDCS using a bioelectric field model of tES. Neural responses were quantified for suprathreshold generation of action potentials in axons and for subthreshold modulation of membrane dynamics in spiking pyramidal neurons. RESULTS IF-tACS and IS-tDCS could not directly activate axons at or below 10 mA, but within this current range, these fields were able to modulate, albeit indirectly, spiking activity in the neuron model. IF-tACS facilitated phase synchronization similar to tACS, and IS-tDCS enhanced and suppressed spiking activity similar to tDCS; however, in either case, the modulatory effects of these fields were less potent than their standard counterparts at a matched field intensity. Moreover, neither IF-tACS nor IS-tDCS improved the spatial selectivity of their parent strategies. CONCLUSIONS Enhancing the spatiotemporal precision and penetrability of tES with interferential and intersectional strategies is possible at the human scale. However, IF-tACS or IS-tDCS will likely require spatial multiplexing with multiple simultaneous sources to counteract their reduced potency, compared to standard techniques, to maintain stimulation currents at tolerable levels.
Collapse
|
20
|
Abstract
Transcranial electric stimulation (tES) protocols strictly need to keep the safety of stimulations and to avoid the unpleasant feelings of stimulated subjects. Following that, the aim of the paper was to find out both the perception and the pain thresholds of different tES modalities. The perception thresholds and the pain thresholds at AF7 and AF8 electrodes with transcranial direct and alternating current stimulation (tDCS and tACS) were performed. Average perception and pain thresholds did not differ significantly inter-individually but intra-individually. With gradually increasing intensity the analysis of thresholds showed that 1) an average participant perceived as first 20 Hz and 40 Hz tACS, then 10 Hz tACS and cathodal tDCS and then anodal tDCS, and 2) the pain was felt first for anodal tDCS, then for 6, 10 and 20 Hz tACS, then for cathodal tDCS and finally for 40 Hz tACS. Besides that, intensity-dependent regularities in feelings of different tES modalities were found. Perception thresholds for 2 types of tDCS (anodal and cathodal) and 4 types of tACS (6-40 Hz) are arranged in sequence of gradually increased values (threshold current): anodal tDCS - cathodal tDCS - 6 - 10 - 20 - 40 Hz tACS. whereas pain thresholds are arranged with decreased threshold values.
Collapse
|
21
|
Abstract
Noninvasive transcranial electric stimulation is increasingly being used as an advantageous therapy alternative that may activate deep tissues while avoiding drug side-effects. However, not only is there limited evidence for activation of deep tissues by transcranial electric stimulation, its evoked human sensation is understudied and often dismissed as a placebo or secondary effect. By systematically characterizing the human sensation evoked by transcranial alternating-current stimulation, we observed not only stimulus frequency and electrode position dependencies specific for auditory and visual sensation but also a broader presence of somatic sensation ranging from touch and vibration to pain and pressure. We found generally monotonic input-output functions at suprathreshold levels, and often multiple types of sensation occurring simultaneously in response to the same electric stimulation. We further used a recording circuit embedded in a cochlear implant to directly and objectively measure the amount of transcranial electric stimulation reaching the auditory nerve, a deep intercranial target located in the densest bone of the skull. We found an optimal configuration using an ear canal electrode and low-frequency (<300 Hz) sinusoids that delivered maximally ~1% of the transcranial current to the auditory nerve, which was sufficient to produce sound sensation even in deafened ears. Our results suggest that frequency resonance due to neuronal intrinsic electric properties need to be explored for targeted deep brain stimulation and novel brain-computer interfaces.
Collapse
|
22
|
Efficiently searching through large tACS parameter spaces using closed-loop Bayesian optimization. Brain Stimul 2019; 12:1484-1489. [PMID: 31289013 PMCID: PMC6879005 DOI: 10.1016/j.brs.2019.07.003] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 06/26/2019] [Accepted: 07/01/2019] [Indexed: 11/25/2022] Open
Abstract
Background Selecting optimal stimulation parameters from numerous possibilities is a major obstacle for assessing the efficacy of non-invasive brain stimulation. Objective We demonstrate that Bayesian optimization can rapidly search through large parameter spaces and identify subject-level stimulation parameters in real-time. Methods To validate the method, Bayesian optimization was employed using participants’ binary judgements about the intensity of phosphenes elicited through tACS. Results We demonstrate the efficiency of Bayesian optimization in identifying parameters that maximize phosphene intensity in a short timeframe (5 min for >190 possibilities). Our results replicate frequency-dependent effects across three montages and show phase-dependent effects of phosphene perception. Computational modelling explains that these phase effects result from constructive/destructive interference of the current reaching the retinas. Simulation analyses demonstrate the method's versatility for complex response functions, even when accounting for noisy observations. Conclusion Alongside subjective ratings, this method can be used to optimize tACS parameters based on behavioral and neural measures and has the potential to be used for tailoring stimulation protocols to individuals.
Collapse
|
23
|
Transcranial alternating current stimulation entrains single-neuron activity in the primate brain. Proc Natl Acad Sci U S A 2019; 116:5747-5755. [PMID: 30833389 DOI: 10.1073/pnas.1815958116] [Citation(s) in RCA: 143] [Impact Index Per Article: 28.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Spike timing is thought to play a critical role in neural computation and communication. Methods for adjusting spike timing are therefore of great interest to researchers and clinicians alike. Transcranial electrical stimulation (tES) is a noninvasive technique that uses weak electric fields to manipulate brain activity. Early results have suggested that this technique can improve subjects' behavioral performance on a wide range of tasks and ameliorate some clinical conditions. Nevertheless, considerable skepticism remains about its efficacy, especially because the electric fields reaching the brain during tES are small, whereas the likelihood of indirect effects is large. Our understanding of its effects in humans is largely based on extrapolations from simple model systems and indirect measures of neural activity. As a result, fundamental questions remain about whether and how tES can influence neuronal activity in the human brain. Here, we demonstrate that tES, as typically applied to humans, affects the firing patterns of individual neurons in alert nonhuman primates, which are the best available animal model for the human brain. Specifically, tES consistently influences the timing, but not the rate, of spiking activity within the targeted brain region. Such effects are frequency- and location-specific and can reach deep brain structures; control experiments show that they cannot be explained by sensory stimulation or other indirect influences. These data thus provide a strong mechanistic rationale for the use of tES in humans and will help guide the development of future tES applications.
Collapse
|
24
|
Probing the Link Between Perception and Oscillations: Lessons from Transcranial Alternating Current Stimulation. Neuroscientist 2019; 26:57-73. [PMID: 30730265 PMCID: PMC7003153 DOI: 10.1177/1073858419828646] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Brain oscillations are regarded as important for perception as they open and close time windows for neural spiking to enable the effective communication within and across brain regions. In the past, studies on perception primarily relied on the use of electrophysiological techniques for probing a correlative link between brain oscillations and perception. The emergence of noninvasive brain stimulation techniques such as transcranial alternating current stimulation (tACS) provides the possibility to study the causal contribution of specific oscillatory frequencies to perception. Here, we review the studies on visual, auditory, and somatosensory perception that employed tACS to probe the causality of brain oscillations for perception. The current literature is consistent with a causal role of alpha and gamma oscillations in parieto-occipital regions for visual perception and theta and gamma oscillations in auditory cortices for auditory perception. In addition, the sensory gating by alpha oscillations applies not only to the visual but also to the somatosensory domain. We conclude that albeit more refined perceptual paradigms and individualized stimulation practices remain to be systematically adopted, tACS is a promising tool for establishing a causal link between neural oscillations and perception.
Collapse
|
25
|
Methods to Compare Predicted and Observed Phosphene Experience in tACS Subjects. Neural Plast 2018; 2018:8525706. [PMID: 30627150 PMCID: PMC6304915 DOI: 10.1155/2018/8525706] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 08/22/2018] [Accepted: 09/17/2018] [Indexed: 01/18/2023] Open
Abstract
Background Phosphene generation is an objective physical measure of potential transcranial alternating current stimulation (tACS) biological side effects. Interpretations from phosphene analysis can serve as a first step in understanding underlying mechanisms of tACS in healthy human subjects and assist validation of computational models. Objective/Hypothesis This preliminary study introduces and tests methods to analyze predicted phosphene occurrence using computational head models constructed from tACS recipients against verbal testimonies of phosphene sensations. Predicted current densities in the eyes and the occipital lobe were also verified against previously published threshold values for phosphenes. Methods Six healthy subjects underwent 10 Hz tACS while being imaged in an MRI scanner. Two different electrode montages, T7-T8 and Fpz-Oz, were used. Subject ratings of phosphene experience were collected during tACS and compared against current density distributions predicted in eye and occipital lobe regions of interest (ROIs) determined for each subject. Calculated median current densities in each ROI were compared to minimum thresholds for phosphene generation. Main Results All subjects reported phosphenes, and predicted median current densities in ROIs exceeded minimum thresholds for phosphenes found in the literature. Higher current densities in the eyes were consistently associated with decreased phosphene generation for the Fpz-Oz montage. There was an overall positive association between phosphene perceptions and current densities in the occipital lobe. Conclusions These methods may have promise for predicting phosphene generation using data collected during in-scanner tACS sessions and may enable better understanding of phosphene origin. Additional empirical data in a larger cohort is required to fully test the robustness of the proposed methods. Future studies should include additional montages that could dissociate retinal and occipital stimulation.
Collapse
|
26
|
Using high-amplitude and focused transcranial alternating current stimulation to entrain physiological tremor. Sci Rep 2018; 8:4927. [PMID: 29563594 PMCID: PMC5862845 DOI: 10.1038/s41598-018-23290-w] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Accepted: 03/08/2018] [Indexed: 01/09/2023] Open
Abstract
Transcranial alternating current stimulation (tACS) is a noninvasive neuromodulation method that can entrain physiological tremor in healthy volunteers. We conducted two experiments to investigate the effectiveness of high-amplitude and focused tACS montages at entraining physiological tremor. Experiment 1 used saline-soaked sponge electrodes with an extra-cephalic return electrode and compared the effects of a motor (MC) and prefrontal cortex (PFC) electrode location. Average peak-amplitude was 1.925 mA. Experiment 2 used gel-filled cup-electrodes in a 4 × 1 focused montage and compared the effects of MC and occipital cortex (OC) tACS. Average peak-amplitude was 4.45 mA. Experiment 1 showed that unfocused MC and PFC tACS both produced phosphenes and significant phase entrainment. Experiment 2 showed that focused MC and OC tACS produced no phosphenes but only focused MC tACS caused significant phase entrainment. At the group level, tACS did not have a significant effect on tremor amplitude. However, with focused tACS there was a significant correlation between phase entrainment and tremor amplitude modulation: subjects with higher phase entrainment showed more tremor amplitude modulation. We conclude that: (1) focused montages allow for high-amplitude tACS without phosphenes and (2) high amplitude focused tACS can entrain physiological tremor.
Collapse
|
27
|
Targeting alpha-band oscillations in a cortical model with amplitude-modulated high-frequency transcranial electric stimulation. Neuroimage 2018; 173:3-12. [PMID: 29427848 DOI: 10.1016/j.neuroimage.2018.02.005] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Revised: 01/11/2018] [Accepted: 02/03/2018] [Indexed: 12/28/2022] Open
Abstract
Non-invasive brain stimulation to target specific network activity patterns, e.g. transcranial alternating current stimulation (tACS), has become an essential tool to understand the causal role of neuronal oscillations in cognition and behavior. However, conventional sinusoidal tACS limits the ability to record neuronal activity during stimulation and lacks spatial focality. One particularly promising new tACS stimulation paradigm uses amplitude-modulated (AM) high-frequency waveforms (AM-tACS) with a slow signal envelope that may overcome the limitations. Moreover. AM-tACS using high-frequency carrier signals is more tolerable than conventional tACS, e.g. in terms of skin irritation and occurrence of phosphenes, when applied at the same current intensities (e.g. 1-2 mA). Yet, the fundamental mechanism of neuronal target-engagement by AM-tACS waveforms has remained unknown. We used a computational model of cortex to investigate how AM-tACS modulates endogenous oscillations and compared the target engagement mechanism to the case of conventional (unmodulated) low-frequency tACS. Analysis of stimulation amplitude and frequency indicated that cortical oscillations were phase-locked to the envelope of the AM stimulation signal, which thus exhibits the same target engagement mechanism as conventional (unmodulated) low frequency tACS. However, in the computational model substantially higher current intensities were needed for AM-tACS than for low-frequency (unmodulated) tACS waveforms to achieve pronounced phase synchronization. Our analysis of the carrier frequency suggests that there might be a trade-off between the use of high-frequency carriers and the stimulation amplitude required for successful entrainment. Together, our computational simulations support the use of slow-envelope high frequency carrier AM waveforms as a tool for noninvasive modulation of brain oscillations. More empirical data will be needed to identify the optimal stimulation parameters and to evaluate tolerability and safety of both, AM- and conventional tACS.
Collapse
|
28
|
Transcranial Alternating Current Stimulation Modulates Risky Decision Making in a Frequency-Controlled Experiment. eNeuro 2017; 4:eN-NWR-0136-17. [PMID: 29379865 PMCID: PMC5779115 DOI: 10.1523/eneuro.0136-17.2017] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Revised: 09/19/2017] [Accepted: 10/09/2017] [Indexed: 11/29/2022] Open
Abstract
In this study, we investigated the effect of transcranial alternating current stimulation (tACS) on voluntary risky decision making and executive control in humans. Stimulation was delivered online at 5 Hz (θ), 10 Hz (α), 20 Hz (β), and 40 Hz (γ) on the left and right frontal area while participants performed a modified risky decision-making task. This task allowed participants to voluntarily select between risky and certain decisions associated with potential gains or losses, while simultaneously measuring the cognitive control component (voluntary switching) of decision making. The purpose of this experimental design was to test whether voluntary risky decision making and executive control can be modulated with tACS in a frequency-specific manner. Our results revealed a robust effect of a 20-Hz stimulation over the left prefrontal area that significantly increased voluntary risky decision making, which may suggest a possible link between risky decision making and reward processing, underlined by β-oscillatory activity.
Collapse
|
29
|
Low intensity transcranial electric stimulation: Safety, ethical, legal regulatory and application guidelines. Clin Neurophysiol 2017; 128:1774-1809. [PMID: 28709880 PMCID: PMC5985830 DOI: 10.1016/j.clinph.2017.06.001] [Citation(s) in RCA: 627] [Impact Index Per Article: 89.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 05/29/2017] [Accepted: 06/06/2017] [Indexed: 12/11/2022]
Abstract
Low intensity transcranial electrical stimulation (TES) in humans, encompassing transcranial direct current (tDCS), transcutaneous spinal Direct Current Stimulation (tsDCS), transcranial alternating current (tACS), and transcranial random noise (tRNS) stimulation or their combinations, appears to be safe. No serious adverse events (SAEs) have been reported so far in over 18,000 sessions administered to healthy subjects, neurological and psychiatric patients, as summarized here. Moderate adverse events (AEs), as defined by the necessity to intervene, are rare, and include skin burns with tDCS due to suboptimal electrode-skin contact. Very rarely mania or hypomania was induced in patients with depression (11 documented cases), yet a causal relationship is difficult to prove because of the low incidence rate and limited numbers of subjects in controlled trials. Mild AEs (MAEs) include headache and fatigue following stimulation as well as prickling and burning sensations occurring during tDCS at peak-to-baseline intensities of 1-2mA and during tACS at higher peak-to-peak intensities above 2mA. The prevalence of published AEs is different in studies specifically assessing AEs vs. those not assessing them, being higher in the former. AEs are frequently reported by individuals receiving placebo stimulation. The profile of AEs in terms of frequency, magnitude and type is comparable in healthy and clinical populations, and this is also the case for more vulnerable populations, such as children, elderly persons, or pregnant women. Combined interventions (e.g., co-application of drugs, electrophysiological measurements, neuroimaging) were not associated with further safety issues. Safety is established for low-intensity 'conventional' TES defined as <4mA, up to 60min duration per day. Animal studies and modeling evidence indicate that brain injury could occur at predicted current densities in the brain of 6.3-13A/m2 that are over an order of magnitude above those produced by tDCS in humans. Using AC stimulation fewer AEs were reported compared to DC. In specific paradigms with amplitudes of up to 10mA, frequencies in the kHz range appear to be safe. In this paper we provide structured interviews and recommend their use in future controlled studies, in particular when trying to extend the parameters applied. We also discuss recent regulatory issues, reporting practices and ethical issues. These recommendations achieved consensus in a meeting, which took place in Göttingen, Germany, on September 6-7, 2016 and were refined thereafter by email correspondence.
Collapse
|
30
|
Frequency-Unspecific Effects of θ-tACS Related to a Visuospatial Working Memory Task. Front Hum Neurosci 2017; 11:367. [PMID: 28747881 PMCID: PMC5506205 DOI: 10.3389/fnhum.2017.00367] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Accepted: 06/28/2017] [Indexed: 02/02/2023] Open
Abstract
Working memory (WM) is crucial for intelligent cognitive functioning, and synchronization phenomena in the fronto-parietal network have been suggested as an underlying neural mechanism. In an attempt to provide causal evidence for this assumption, we applied transcranial alternating current stimulation (tACS) at theta frequency over fronto-parietal sites during a visuospatial match-to-sample (MtS) task. Depending on the stimulation protocol, i.e., in-phase, anti-phase or sham, we anticipated a differential impact of tACS on behavioral WM performance as well as on the EEG (electroencephalography) during resting state before and after stimulation. We hypothesized that in-phase tACS of the fronto-parietal theta network (stimulation frequency: 5 Hz; intensity: 1 mA peak-to-peak) would result in performance enhancement, whereas anti-phase tACS would cause performance impairment. Eighteen participants (nine female) received in-phase, anti-phase, and sham stimulation in balanced order. While being stimulated, subjects performed the MtS task, which varied in executive demand (two levels: low and high). EEG analysis of power peaks within the delta (0.5–4 Hz), theta (4–8 Hz), alpha (8–12 Hz), and beta (12–30 Hz) frequency bands was carried out. No significant differences were observed between in-phase and anti-phase stimulation regarding both behavioral and EEG measurements. Yet, with regard to the alpha frequency band, we observed a statistically significant drop of peak power from pre to post in the sham condition, whereas alpha power remained on a similar level in the actively stimulated conditions. Our results indicate a frequency-unspecific modulation of neuronal oscillations by tACS. However, the closer participants’ individual theta peak frequencies were to the stimulation frequency of 5 Hz after anti-phase tACS, the faster they responded in the MtS task. This effect did not reach statistical significance during in-phase tACS and was not present during sham. A lack of statistically significant behavioral results in the MtS task and frequency-unspecific effects on the electrophysiological level question the effectiveness of tACS in modulating cortical oscillations in a frequency-specific manner.
Collapse
|
31
|
Transcranial Random Noise Stimulation of Visual Cortex: Stochastic Resonance Enhances Central Mechanisms of Perception. J Neurosci 2017; 36:5289-98. [PMID: 27170126 DOI: 10.1523/jneurosci.4519-15.2016] [Citation(s) in RCA: 104] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 03/26/2016] [Indexed: 11/21/2022] Open
Abstract
UNLABELLED Random noise enhances the detectability of weak signals in nonlinear systems, a phenomenon known as stochastic resonance (SR). Though counterintuitive at first, SR has been demonstrated in a variety of naturally occurring processes, including human perception, where it has been shown that adding noise directly to weak visual, tactile, or auditory stimuli enhances detection performance. These results indicate that random noise can push subthreshold receptor potentials across the transfer threshold, causing action potentials in an otherwise silent afference. Despite the wealth of evidence demonstrating SR for noise added to a stimulus, relatively few studies have explored whether or not noise added directly to cortical networks enhances sensory detection. Here we administered transcranial random noise stimulation (tRNS; 100-640 Hz zero-mean Gaussian white noise) to the occipital region of human participants. For increasing tRNS intensities (ranging from 0 to 1.5 mA), the detection accuracy of a visual stimuli changed according to an inverted-U-shaped function, typical of the SR phenomenon. When the optimal level of noise was added to visual cortex, detection performance improved significantly relative to a zero noise condition (9.7 ± 4.6%) and to a similar extent as optimal noise added to the visual stimuli (11.2 ± 4.7%). Our results demonstrate that adding noise to cortical networks can improve human behavior and that tRNS is an appropriate tool to exploit this mechanism. SIGNIFICANCE STATEMENT Our findings suggest that neural processing at the network level exhibits nonlinear system properties that are sensitive to the stochastic resonance phenomenon and highlight the usefulness of tRNS as a tool to modulate human behavior. Since tRNS can be applied to all cortical areas, exploiting the SR phenomenon is not restricted to the perceptual domain, but can be used for other functions that depend on nonlinear neural dynamics (e.g., decision making, task switching, response inhibition, and many other processes). This will open new avenues for using tRNS to investigate brain function and enhance the behavior of healthy individuals or patients.
Collapse
|
32
|
Abstract
Transcranial alternating current stimulation (tACS) is a promising tool for noninvasive investigation of brain oscillations. TACS employs frequency-specific stimulation of the human brain through current applied to the scalp with surface electrodes. Most current knowledge of the technique is based on behavioral studies; thus, combining the method with brain imaging holds potential to better understand the mechanisms of tACS. Because of electrical and susceptibility artifacts, combining tACS with brain imaging can be challenging, however, one brain imaging technique that is well suited to be applied simultaneously with tACS is functional magnetic resonance imaging (fMRI). In our lab, we have successfully combined tACS with simultaneous fMRI measurements to show that tACS effects are state, current, and frequency dependent, and that modulation of brain activity is not limited to the area directly below the electrodes. This article describes a safe and reliable setup for applying tACS simultaneously with visual task fMRI studies, which can lend to understanding oscillatory brain function as well as the effects of tACS on the brain.
Collapse
|
33
|
Enhancement of multitasking performance and neural oscillations by transcranial alternating current stimulation. PLoS One 2017; 12:e0178579. [PMID: 28562642 PMCID: PMC5451121 DOI: 10.1371/journal.pone.0178579] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 05/15/2017] [Indexed: 01/10/2023] Open
Abstract
Multitasking is associated with the generation of stimulus-locked theta (4–7 Hz) oscillations arising from prefrontal cortex (PFC). Transcranial alternating current stimulation (tACS) is a non-invasive brain stimulation technique that influences endogenous brain oscillations. Here, we investigate whether applying alternating current stimulation within the theta frequency band would affect multitasking performance, and explore tACS effects on neurophysiological measures. Brief runs of bilateral PFC theta-tACS were applied while participants were engaged in a multitasking paradigm accompanied by electroencephalography (EEG) data collection. Unlike an active control group, a tACS stimulation group showed enhancement of multitasking performance after a 90-minute session (F1,35 = 6.63, p = 0.01, ηp2 = 0.16; effect size = 0.96), coupled with significant modulation of posterior beta (13–30 Hz) activities (F1,32 = 7.66, p = 0.009, ηp2 = 0.19; effect size = 0.96). Across participant regression analyses indicated that those participants with greater increases in frontal theta, alpha and beta oscillations exhibited greater multitasking performance improvements. These results indicate frontal theta-tACS generates benefits on multitasking performance accompanied by widespread neuronal oscillatory changes, and suggests that future tACS studies with extended treatments are worth exploring as promising tools for cognitive enhancement.
Collapse
|
34
|
Driving Human Motor Cortical Oscillations Leads to Behaviorally Relevant Changes in Local GABA A Inhibition: A tACS-TMS Study. J Neurosci 2017; 37:4481-4492. [PMID: 28348136 PMCID: PMC5413186 DOI: 10.1523/jneurosci.0098-17.2017] [Citation(s) in RCA: 80] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Revised: 03/02/2017] [Accepted: 03/08/2017] [Indexed: 12/23/2022] Open
Abstract
Beta and gamma oscillations are the dominant oscillatory activity in the human motor cortex (M1). However, their physiological basis and precise functional significance remain poorly understood. Here, we used transcranial magnetic stimulation (TMS) to examine the physiological basis and behavioral relevance of driving beta and gamma oscillatory activity in the human M1 using transcranial alternating current stimulation (tACS). tACS was applied using a sham-controlled crossover design at individualized intensity for 20 min and TMS was performed at rest (before, during, and after tACS) and during movement preparation (before and after tACS). We demonstrated that driving gamma frequency oscillations using tACS led to a significant, duration-dependent decrease in local resting-state GABAA inhibition, as quantified by short interval intracortical inhibition. The magnitude of this effect was positively correlated with the magnitude of GABAA decrease during movement preparation, when gamma activity in motor circuitry is known to increase. In addition, gamma tACS-induced change in GABAA inhibition was closely related to performance in a motor learning task such that subjects who demonstrated a greater increase in GABAA inhibition also showed faster short-term learning. The findings presented here contribute to our understanding of the neurophysiological basis of motor rhythms and suggest that tACS may have similar physiological effects to endogenously driven local oscillatory activity. Moreover, the ability to modulate local interneuronal circuits by tACS in a behaviorally relevant manner provides a basis for tACS as a putative therapeutic intervention.SIGNIFICANCE STATEMENT Gamma oscillations have a vital role in motor control. Using a combined tACS-TMS approach, we demonstrate that driving gamma frequency oscillations modulates GABAA inhibition in the human motor cortex. Moreover, there is a clear relationship between the change in magnitude of GABAA inhibition induced by tACS and the magnitude of GABAA inhibition observed during task-related synchronization of oscillations in inhibitory interneuronal circuits, supporting the hypothesis that tACS engages endogenous oscillatory circuits. We also show that an individual's physiological response to tACS is closely related to their ability to learn a motor task. These findings contribute to our understanding of the neurophysiological basis of motor rhythms and their behavioral relevance and offer the possibility of developing tACS as a therapeutic tool.
Collapse
|
35
|
Guiding transcranial brain stimulation by EEG/MEG to interact with ongoing brain activity and associated functions: A position paper. Clin Neurophysiol 2017; 128:843-857. [PMID: 28233641 DOI: 10.1016/j.clinph.2017.01.003] [Citation(s) in RCA: 157] [Impact Index Per Article: 22.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 12/10/2016] [Accepted: 01/08/2017] [Indexed: 01/31/2023]
Abstract
Non-invasive transcranial brain stimulation (NTBS) techniques have a wide range of applications but also suffer from a number of limitations mainly related to poor specificity of intervention and variable effect size. These limitations motivated recent efforts to focus on the temporal dimension of NTBS with respect to the ongoing brain activity. Temporal patterns of ongoing neuronal activity, in particular brain oscillations and their fluctuations, can be traced with electro- or magnetoencephalography (EEG/MEG), to guide the timing as well as the stimulation settings of NTBS. These novel, online and offline EEG/MEG-guided NTBS-approaches are tailored to specifically interact with the underlying brain activity. Online EEG/MEG has been used to guide the timing of NTBS (i.e., when to stimulate): by taking into account instantaneous phase or power of oscillatory brain activity, NTBS can be aligned to fluctuations in excitability states. Moreover, offline EEG/MEG recordings prior to interventions can inform researchers and clinicians how to stimulate: by frequency-tuning NTBS to the oscillation of interest, intrinsic brain oscillations can be up- or down-regulated. In this paper, we provide an overview of existing approaches and ideas of EEG/MEG-guided interventions, and their promises and caveats. We point out potential future lines of research to address challenges.
Collapse
|
36
|
5 kHz Transcranial Alternating Current Stimulation: Lack of Cortical Excitability Changes When Grouped in a Theta Burst Pattern. Front Hum Neurosci 2017; 10:683. [PMID: 28119589 PMCID: PMC5222864 DOI: 10.3389/fnhum.2016.00683] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2016] [Accepted: 12/21/2016] [Indexed: 11/15/2022] Open
Abstract
Background: Suprathreshold transcranial single pulse electrical stimulation (tES) is painful and not applicable in a repetitive mode to induce plastic after-effects. Objective: In order to circumvent this pain problem, we applied here a 5 kHz transcranial alternating current stimulation (tACS) theta burst protocol with a field intensity of up to 10 mA to the primary motor cortex (M1). Furthermore, we were interested in finding out whether electrical theta burst stimulation (eTBS) is able to induce lasting after-effects on cortical plasticity. Methods: Three different eTBS protocols were applied at 5 mA in a sham controlled, double blinded cross-over design on the M1 region of seventeen healthy subjects during the first part of the study. The second study part consists of three different eTBS protocols ranging from 5 mA to 10 mA and 1 ms to 5 ms sinusoidal bursts, applied to the M1 region of 14 healthy subjects. Results: We were able to apply all eTBS protocols in a safe manner, with only six subjects reporting mild side effects related to the stimulation. However, no eTBS protocol induced lasting effects on muscle- evoked potential (MEP) amplitudes when compared to sham stimulation. Significant inhibition of MEP amplitude was only seen in the lower intensity protocols as compared to baseline. Conclusion: eTBS is a safe method to apply high frequency tACS with up to 10 mA intensity. Future studies need to explore the parameter space to a larger extent in order to assure efficacy.
Collapse
|
37
|
Adverse events of tDCS and tACS: A review. Clin Neurophysiol Pract 2016; 2:19-25. [PMID: 30214966 PMCID: PMC6123849 DOI: 10.1016/j.cnp.2016.12.003] [Citation(s) in RCA: 167] [Impact Index Per Article: 20.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Revised: 12/02/2016] [Accepted: 12/05/2016] [Indexed: 01/25/2023] Open
Abstract
Transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS) have been applied to many research issues because these stimulation techniques can modulate neural activity in the human brain painlessly and non-invasively with weak electrical currents. However, there are no formal safety guidelines for the selection of stimulus parameters in either tDCS or tACS. As a means of gathering the information that is needed to produce safety guidelines, in this article, we summarize the adverse events of tDCS and tACS. In both stimulation techniques, most adverse effects are mild and disappear soon after stimulation. Nevertheless, several papers have reported that, in tDCS, some adverse events persist even after stimulation. The persistent events consist of skin lesions similar to burns, which can arise even in healthy subjects, and mania or hypomania in patients with depression. Recently, one paper reported a pediatric patient presenting with seizure after tDCS, although the causal relationship between stimulation and seizure is not clear. As this seizure is the only serious adverse events yet reported in connection with tDCS, tDCS is considered safe. In tACS, meanwhile, no persistent adverse events have been reported, but considerably fewer reports are available on the safety of tACS than on the safety of tDCS. Therefore, to establish the safety of tDCS and tACS, we need to scan the literature continuously for information on the adverse events of both stimulation techniques. Further safety investigations are also required.
Collapse
|
38
|
Phase and Frequency-Dependent Effects of Transcranial Alternating Current Stimulation on Motor Cortical Excitability. PLoS One 2016; 11:e0162521. [PMID: 27607431 PMCID: PMC5015848 DOI: 10.1371/journal.pone.0162521] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Accepted: 08/24/2016] [Indexed: 01/01/2023] Open
Abstract
Transcranial alternating current stimulation (tACS) can entrain ongoing brain oscillations and modulate the motor system in a frequency-dependent manner. Recent animal studies have demonstrated that the phase of a sinusoidal current also has an important role in modulation of neuronal activity. However, the phase effects of tACS on the human motor system are largely unknown. Here, we systematically investigated the effects of tACS phase and frequency on the primary motor cortex (M1) by using motor evoked potentials (MEPs) with transcranial magnetic stimulation (TMS). First, we compared the phase effects (90°, 180°, 270° or 360°) of 10 and 20 Hz tACS on MEPs. The 20 Hz tACS significantly increased M1 excitability compared with the 10 Hz tACS at 90° phase only. Second, we studied the 90° phase effect on MEPs at different tACS frequencies (5, 10, 20 or 40 Hz). The 20 vs. 10 Hz difference was again observed, but the 90° phase in 5 and 40 Hz tACS did not influence M1 excitability. Third, the 90° phase effects of 10 and 20 Hz tACS were compared with sham stimulation. The 90° phase of 20 Hz tACS enhanced MEP amplitudes compared with sham stimulation, but there was no significant effect of 10 Hz tACS. Taken together, we assume that the differential 90° phase effects on 20 Hz and 10 Hz tACS can be attributed to the neural synchronization modulated by tACS. Our results further underline that phase and frequency are the important factors in the effects of tACS on M1 excitability.
Collapse
|
39
|
Tolerability of Repeated Application of Transcranial Electrical Stimulation with Limited Outputs to Healthy Subjects. Brain Stimul 2016; 9:740-754. [PMID: 27372844 DOI: 10.1016/j.brs.2016.05.008] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Revised: 05/20/2016] [Accepted: 05/22/2016] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND The safety and tolerability of limited output transcranial electrical stimulation (tES) in clinical populations support a non-significant risk designation. The tolerability of long-term use in a healthy population had remained untested. OBJECTIVE We tested the tolerability and compliance of two tES waveforms, transcranial direct current stimulation (tDCS) and modulated high frequency transcranial pulsed current stimulation (MHF-tPCS) compared to sham-tDCS, applied to healthy subjects for three to five days (17-20 minutes per day) per week for up to six weeks in a communal setting. MHF-tPCS consisted of asymmetric high-frequency pulses (7-11 kHz) having a peak amplitude of 10-20 mA peak, adjusted by subject, resulting in an average current of 5-7 mA. METHOD A total of 100 treatment blind healthy subjects were randomly assigned to one of three treatment groups: tDCS (n = 33), MHF-tPCS (n = 30), or sham-tDCS (n = 37). In order to test the role of waveform, electrode type and montage were fixed across tES and sham-tDCS arms: high-capacity self-adhering electrodes on the right lateral forehead and back of the neck. We conducted 1905 sessions (636 sham-tDCS, 623 tDCS, and 646 MHF-tPCS sessions) on study volunteers over a period of six weeks. RESULTS Common adverse events were primarily restricted to influences upon the skin and included skin tingling, itching, and mild burning sensations. The incidence of these events in the active tES treatment arms (MHF-tPCS, tDCS) was equivalent or significantly lower than their incidence in the sham-tDCS treatment arm. Other adverse events had a rarity (<5% incidence) that could not be significantly distinguished across the treatment groups. Some subjects were withdrawn from the study due to atypical headache (sham-tDCS n = 2, tDCS n = 2, and MHF-tPCS n = 3), atypical discomfort (sham-tDCS n = 0, tDCS n = 1, and MHF-tPCS n = 1), or atypical skin irritation (sham-tDCS n = 2, tDCS n = 8, and MHF-tPCS n = 1). The rate of compliance, elected sessions completed, for the MHF-tPCS group was significantly greater than the sham-tDCS group's compliance (p = 0.007). There were no serious adverse events in any treatment condition. CONCLUSION We conclude that repeated application of limited output tES across extended periods, limited to the hardware, electrodes, and protocols tested here, is well tolerated in healthy subjects, as previously observed in clinical populations.
Collapse
|
40
|
Beta Band Transcranial Alternating (tACS) and Direct Current Stimulation (tDCS) Applied After Initial Learning Facilitate Retrieval of a Motor Sequence. Front Behav Neurosci 2016; 10:4. [PMID: 26834593 PMCID: PMC4722123 DOI: 10.3389/fnbeh.2016.00004] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Accepted: 01/04/2016] [Indexed: 11/15/2022] Open
Abstract
The primary motor cortex (M1) contributes to the acquisition and early consolidation of a motor sequence. Although the relevance of M1 excitability for motor learning has been supported, the significance of M1 oscillations remains an open issue. This study aims at investigating to what extent retrieval of a newly learned motor sequence can be differentially affected by motor-cortical transcranial alternating (tACS) and direct current stimulation (tDCS). Alpha (10 Hz), beta (20 Hz) or sham tACS was applied in 36 right-handers. Anodal or cathodal tDCS was applied in 30 right-handers. Participants learned an eight-digit serial reaction time task (SRTT; sequential vs. random) with the right hand. Stimulation was applied to the left M1 after SRTT acquisition at rest for 10 min. Reaction times were analyzed at baseline, end of acquisition, retrieval immediately after stimulation and reacquisition after eight further sequence repetitions. Reaction times during retrieval were significantly faster following 20 Hz tACS as compared to 10 Hz and sham tACS indicating a facilitation of early consolidation. tDCS yielded faster reaction times, too, independent of polarity. No significant differences between 20 Hz tACS and tDCS effects on retrieval were found suggesting that 20 Hz effects might be associated with altered motor-cortical excitability. Based on the behavioral modulation yielded by tACS and tDCS one might speculate that altered motor-cortical beta oscillations support early motor consolidation possibly associated with neuroplastic reorganization.
Collapse
|
41
|
Abstract
Abstract. Low-intensity transcranial electrical stimulation (tES) techniques are a group of noninvasive brain stimulation approaches, where currents are applied with intensities ranging between 0.4 and 2 mA through the human scalp. The most frequently used tES methods are transcranial direct current (tDCS), alternating current (tACS), and random noise stimulation (tRNS). These methods have been shown to induce changes in cortical excitability and activity during and after the stimulation in a reversible manner. It was observed that while anodal and cathodal tDCS acts on the membrane potentials by depolarizing or hyperpolarizing them, tACS probably modifies cortical oscillations. tRNS, that is a special form of tACS, might act through affecting the signal-to-noise ratio in the brain. Currently, an exponentially increasing number of studies have been published regarding the effects of tES on physiological processes and cognition. The aim of this review is to summarize the basic aspects of tES methods.
Collapse
|
42
|
A technical guide to tDCS, and related non-invasive brain stimulation tools. Clin Neurophysiol 2015; 127:1031-1048. [PMID: 26652115 DOI: 10.1016/j.clinph.2015.11.012] [Citation(s) in RCA: 786] [Impact Index Per Article: 87.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Revised: 11/14/2015] [Accepted: 11/17/2015] [Indexed: 01/29/2023]
Abstract
Transcranial electrical stimulation (tES), including transcranial direct and alternating current stimulation (tDCS, tACS) are non-invasive brain stimulation techniques increasingly used for modulation of central nervous system excitability in humans. Here we address methodological issues required for tES application. This review covers technical aspects of tES, as well as applications like exploration of brain physiology, modelling approaches, tES in cognitive neurosciences, and interventional approaches. It aims to help the reader to appropriately design and conduct studies involving these brain stimulation techniques, understand limitations and avoid shortcomings, which might hamper the scientific rigor and potential applications in the clinical domain.
Collapse
|
43
|
From amusic to musical?--Improving pitch memory in congenital amusia with transcranial alternating current stimulation. Behav Brain Res 2015; 294:141-8. [PMID: 26254878 DOI: 10.1016/j.bbr.2015.08.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Revised: 07/29/2015] [Accepted: 08/03/2015] [Indexed: 11/29/2022]
Abstract
Brain imaging studies highlighted structural differences in congenital amusia, a life-long perceptual disorder that is associated with pitch perception and pitch memory deficits. A functional anomaly characterized by decreased low gamma oscillations (30-40 Hz range) in the right dorsolateral prefrontal cortex (DLPFC) during pitch memory has been revealed recently. Thus, the present study investigates whether applying transcranial alternating current stimulation (tACS) at 35 Hz to the right DLPFC would improve pitch memory. Nine amusics took part in two tACS sessions (either 35 Hz or 90 Hz) and completed a pitch and visual memory task before and during stimulation. 35 Hz stimulation facilitated pitch memory significantly. No modulation effects were found with 90 Hz stimulation or on the visual task. While amusics showed a selective impairment of pitch memory before stimulation, the performance during 35 Hz stimulation was not significantly different to healthy controls anymore. Taken together, the study shows that modulating the right DLPFC with 35 Hz tACS in congenital amusia selectively improves pitch memory performance supporting the hypothesis that decreased gamma oscillations within the DLPFC are causally involved in disturbed pitch memory and highlight the potential use of tACS to interact with cognitive processes.
Collapse
|
44
|
Anodal Transcranial Pulsed Current Stimulation: The Effects of Pulse Duration on Corticospinal Excitability. PLoS One 2015; 10:e0131779. [PMID: 26177541 PMCID: PMC4503737 DOI: 10.1371/journal.pone.0131779] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2015] [Accepted: 06/05/2015] [Indexed: 11/19/2022] Open
Abstract
The aim is to investigate the effects of pulse duration (PD) on the modulatory effects of transcranial pulsed current (tPCS) on corticospinal excitability (CSE). CSE of the dominant primary motor cortex (M1) of right first dorsal interosseous muscle was assessed by motor evoked potentials, before, immediately, 10, 20 and 30 minutes after application of five experimental conditions: 1) anodal transcranial direct current stimulation (a-tDCS), 2) a-tPCS with 125 ms pulse duartion (a-tPCSPD = 125), 3) a-tPCS with 250 ms pulse duration (a-tPCSPD = 250), 4) a-tPCS with 500 ms pulse duration (a-tPCSPD = 500) and 5) sham a-tPCS. The total charges were kept constant in all experimental conditions except sham condition. Post-hoc comparisons indicated that a-tPCSPD = 500 produced larger CSE compared to a-tPCSPD = 125 (P<0.0001), a-tPCSPD = 250 (P = 0.009) and a-tDCS (P = 0.008). Also, there was no significant difference between a-tPCSPD = 250 and a-tDCS on CSE changes (P>0.05). All conditions except a-tPCSPD = 125 showed a significant difference to the sham group (P<0.006). All participants tolerated the applied currents. It could be concluded that a-tPCS with a PD of 500ms induces largest CSE changes, however further studies are required to identify optimal values.
Collapse
|
45
|
Functional role of frontal alpha oscillations in creativity. Cortex 2015; 67:74-82. [PMID: 25913062 DOI: 10.1016/j.cortex.2015.03.012] [Citation(s) in RCA: 87] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2014] [Revised: 01/29/2015] [Accepted: 03/19/2015] [Indexed: 02/02/2023]
Abstract
Creativity, the ability to produce innovative ideas, is a key higher-order cognitive function that is poorly understood. At the level of macroscopic cortical network dynamics, recent electroencephalography (EEG) data suggests that cortical oscillations in the alpha frequency band (8-12 Hz) are correlated with creative thinking. However, whether alpha oscillations play a functional role in creativity has remained unknown. Here we show that creativity is increased by enhancing alpha power using 10 Hz transcranial alternating current stimulation (10 Hz-tACS) of the frontal cortex. In a study of 20 healthy participants with a randomized, balanced cross-over design, we found a significant improvement of 7.4% in the Creativity Index measured by the Torrance Test of Creative Thinking (TTCT), a comprehensive and most frequently used assay of creative potential and strengths. In a second similar study with 20 subjects, 40 Hz-tACS was used instead of 10 Hz-tACS to rule out a general "electrical stimulation" effect. No significant change in the Creativity Index was found for such frontal 40 Hz stimulation. Our results suggest that alpha activity in frontal brain areas is selectively involved in creativity; this enhancement represents the first demonstration of specific neuronal dynamics that drive creativity and can be modulated by non-invasive brain stimulation. Our findings agree with the model that alpha recruitment increases with internal processing demands and is involved in inhibitory top-down control, which is an important requirement for creative ideation.
Collapse
|
46
|
The impact of electrical stimulation techniques on behavior. WILEY INTERDISCIPLINARY REVIEWS. COGNITIVE SCIENCE 2014; 5:649-659. [PMID: 26308871 DOI: 10.1002/wcs.1319] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 07/23/2014] [Accepted: 08/10/2014] [Indexed: 12/22/2022]
Abstract
UNLABELLED Low-intensity transcranial electrical stimulation (tES) methods are a group of noninvasive brain stimulation techniques, whereby currents are applied with intensities typically ranging between 1 and 2 mA, through the human scalp. These techniques have been shown to induce changes in cortical excitability and activity during and after the stimulation in a reversible manner. They include transcranial direct current simulation (tDCS), transcranial alternating current simulation (tACS), and transcranial random noise stimulation (tRNS). Currently, an increasing number of studies have been published regarding the effects of tES on cognitive performance and behavior. Processes of learning and increases in cognitive performance are accompanied by changes in cortical plasticity. tES can impact upon these processes and is able to affect task execution. Many studies have been based on the accepted idea that by increasing cortical excitability (e.g., by applying anodal tDCS) or coherence of oscillatory activity (e.g., by applying tACS) an increase in performance should be detected; however, a number of studies now suggest that the basic knowledge of the mechanisms of action is insufficient to predict the outcome of applied stimulation on the execution of a cognitive or behavioral task, and so far no standard paradigms for increasing cortical plasticity changes during learning or cognitive tasks have been established. The aim of this review is to summarize recent findings with regard to the effects of tES on behavior concentrating on the motor and visual areas. WIREs Cogn Sci 2014, 5:649-659. doi: 10.1002/wcs.1319 For further resources related to this article, please visit the WIREs website. CONFLICT OF INTEREST The authors have declared no conflicts of interest for this article.
Collapse
|
47
|
Abstract
Transcranial alternating current stimulation (tACS) seems likely to open a new era of the field of noninvasive electrical stimulation of the human brain by directly interfering with cortical rhythms. It is expected to synchronize (by one single resonance frequency) or desynchronize (e.g., by the application of several frequencies) cortical oscillations. If applied long enough it may cause neuroplastic effects. In the theta range it may improve cognition when applied in phase. Alpha rhythms could improve motor performance, whereas beta intrusion may deteriorate them. TACS with both alpha and beta frequencies has a high likelihood to induce retinal phosphenes. Gamma intrusion can possibly interfere with attention. Stimulation in the “ripple” range induces intensity dependent inhibition or excitation in the motor cortex (M1) most likely by entrainment of neuronal networks, whereas stimulation in the low kHz range induces excitation by neuronal membrane interference. TACS in the 200 kHz range may have a potential in oncology.
Collapse
|