Miles JE, Mazdarani P. Effect of center of rotation of angulation-based levelling osteotomy on instantaneous center of rotation ex vivo. Vet Res Commun 2024; 48:1845-1851. [PMID: 38282014 PMCID: PMC11147888 DOI: 10.1007/s11259-024-10314-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 01/18/2024] [Indexed: 01/30/2024]
Abstract
Cranial cruciate ligament rupture is a common cause of femorotibial instability in dogs. Despite numerous techniques being described for achieving joint stabilization, no consensus exists on the optimal management strategy. This ex vivo study utilized the path of the instantaneous center of rotation (ICR) to compare normal, pathological and treated joints. Fluoroscopic recordings of seven limbs from a previous study of canine stifle joint stability following center of rotation of angulation-based levelling osteotomy (CBLO) with and without hamstring loading were analyzed using least-squares approximation of the ICR and estimation of percentage gliding (vs. rolling) to determine if alterations in ICR path and gliding caused by CCL transection and following meniscal release could be normalized by CBLO. In intact joints, the ICR path was located mid-condyle, but this shifted significantly proximally and caudally following CCL transection and medial meniscal release (p < 0.007, p < 0.04). Hamstring loading resulted in qualitative and some quantitative improvements in joint movement based on percentage gliding movement analysis. The ICR path after CBLO remained significantly different to the intact location with or without a hamstring load (p < 0.02, p < 0.04), potentially consistent with CBLO aims of mild residual instability. CBLO resulted in percentage gliding characteristics not significantly different to intact joints (p > 0.08). Qualitative improvements in ICR path and percentage gliding quantities and variability suggest that hamstring loading positively influences joint biomechanics and that further investigation of this role ex vivo and clinically is warranted.
Collapse
Affiliation(s)
- James Edward Miles
- Department of Veterinary Clinical Sciences, University of Copenhagen, Dyrlaegevej 16, Frederiksberg C, 1870, Denmark.
| | - Parisa Mazdarani
- Current address: College of Veterinary Medicine, University of Florida, 2015 SW 16th Ave, Gainesville, FL, 32608, USA
| |
Collapse
|
2
|
Bologna FA, Putame G, Audenino AL, Terzini M. Understanding the role of head size and neck length in micromotion generation at the taper junction in total hip arthroplasty. Sci Rep 2024; 14:6397. [PMID: 38493233 PMCID: PMC10944531 DOI: 10.1038/s41598-024-57017-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 03/13/2024] [Indexed: 03/18/2024] Open
Abstract
Modular hip implants allow intra-operative adjustments for patient-specific customization and targeted replacement of damaged elements without full implant extraction. However, challenges arise from relative micromotions between components, potentially leading to implant failure due to cytotoxic metal debris. In this study magnitude and directions of micromotions at the taper junction were estimated, aiming to understand the effect of variations in head size and neck length. Starting from a reference configuration adhering to the 12/14 taper standard, six additional implant configurations were generated by varying the head size and/or neck length. A musculoskeletal multibody model of a prothesized lower limb was developed to estimate hip contact force and location during a normal walking task. Following the implant assembly, the multibody-derived loads were imposed as boundary conditions in a finite element analysis to compute the taper junction micromotions as the relative slip between the contacting surfaces. Results highlighted the L-size head as the most critical configuration, indicating a 2.81 μm relative slip at the mid-stance phase. The proposed approach enables the investigation of geometric variations in implants under accurate load conditions, providing valuable insights for designing less risky prostheses and informing clinical decision-making processes.
Collapse
Affiliation(s)
- Federico A Bologna
- PolitoBIOMed Lab, Politecnico di Torino, 10129, Turin, Italy
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy
| | - Giovanni Putame
- PolitoBIOMed Lab, Politecnico di Torino, 10129, Turin, Italy
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy
| | - Alberto L Audenino
- PolitoBIOMed Lab, Politecnico di Torino, 10129, Turin, Italy
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy
| | - Mara Terzini
- PolitoBIOMed Lab, Politecnico di Torino, 10129, Turin, Italy.
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy.
| |
Collapse
|
3
|
Coskun Ö, Viskjer S. Evaluating the outcome after center of rotation of angulation (CORA)-based leveling osteotomy (CBLO) technique to repair unilateral cranial cruciate ligament deficiency using a pressure-sensitive walkway system. CANADIAN JOURNAL OF VETERINARY RESEARCH = REVUE CANADIENNE DE RECHERCHE VETERINAIRE 2023; 87:157-164. [PMID: 37020578 PMCID: PMC10069156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 08/25/2022] [Indexed: 04/07/2023]
Abstract
The objective of this study was to evaluate the mid-term outcome of center of rotation of angulation (CORA)-based leveling osteotomy (CBLO) in dogs with cranial cruciate ligament (CrCL) deficiency using a pressure-sensitive walkway system. Fifteen dogs with unilateral CrCL deficiency were treated with CBLO for an average of 50 wk (median 46 wk, range: 38 to 91) prior to the evaluation. The contralateral hind limb was confirmed free of any signs of pathology by clinical examination and lateral stifle radiography. A control group of 20 healthy dogs was included to establish reference values for comparison purposes. Spatiotemporal parameters and peak vertical force (PVF) were measured and symmetry index (SI) was calculated between the left and right pelvic limb and between thoracic and pelvic limbs, in both groups. The mean hind limb SI for the 15 CBLO-treated dogs and the 20 dogs in the control group was 1.02 ± 0.1 and 1.03 ± 0.07, respectively, the difference being not significant (P = 0.75). There was no significant difference in the thoracic limb/pelvic limb ratio between the 2 groups (P = 0.42). The dogs' recovery was objectively measured on a pressure-sensitive walkway and the CrCL-deficient dogs had returned to full functioning within 6 to 12 mo. Center of rotation of angulation-based leveling osteotomy provided normal function of the operated hind limb and should be considered as an option for treating canine CrCL deficiency.
Collapse
Affiliation(s)
- Ömer Coskun
- Evidensia Specialist Animal Hospital, Djursjukhusvägen 11, 73494 Strömsholm, Sweden
| | - Sivert Viskjer
- Evidensia Specialist Animal Hospital, Djursjukhusvägen 11, 73494 Strömsholm, Sweden
| |
Collapse
|
4
|
Multibody Computer Model of the Entire Equine Forelimb Simulates Forces Causing Catastrophic Fractures of the Carpus during a Traditional Race. Animals (Basel) 2022; 12:ani12060737. [PMID: 35327134 PMCID: PMC8944875 DOI: 10.3390/ani12060737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Revised: 03/01/2022] [Accepted: 03/11/2022] [Indexed: 11/29/2022] Open
Abstract
Simple Summary Palios are traditional horseraces held in the main square of few Italian cities. Due to peculiar features of such circuits, adapted to the square architecture and thus characterized by tight curves and unconventional footing surface, horses involved are at particular risk of accidents. Prevention of catastrophic musculoskeletal injuries is a significant issue and matter of debate during these events. In particular, the negotiation of the curves in the city circuits is a significative concern. An experiment was set up to build a model of entire forelimb at the point of failure in the context of a turn comparable to that in a Palio circuit. The model was informed by live data and the output compared to post-mortem findings obtained from a horse that sustained a catastrophic fracture of the carpus during this competition. The objective of this study is to determine the magnitude and distribution of internal forces generated across the carpus under which the catastrophic injury has occurred and describe related post-mortem findings. Abstract A catastrophic fracture of the radial carpal bone experienced by a racehorse during a Palio race was analyzed. Computational modelling of the carpal joint at the point of failure informed by live data was generated using a multibody code for dynamics simulation. The circuit design in a turn, the speed of the animal and the surface characteristics were considered in the model. A macroscopic examination of the cartilage, micro-CT and histology were performed on the radio-carpal joint of the limb that sustained the fracture. The model predicted the points of contact forces generated at the level of the radio-carpal joint where the fracture occurred. Articular surfaces of the distal radius, together with the proximal articular surface of small carpal bones, exhibited diffuse wear lines, erosions of the articular cartilage and subchondral bone exposure. Even though the data in this study originated from a single fracture and further work will be required to validate this approach, this study highlights the potential correlation between elevated impact forces generated at the level of contact surfaces of the carpal joint during a turn and cartilage breakdown in the absence of pre-existing pathology. Computer modelling resulted in a useful tool to inversely calculate internal forces generated during specific conditions that cannot be reproduced in-vivo because of ethical concerns.
Collapse
|
5
|
Mazdarani P, Pedram MS, Miles JE. Effect of center of angulation of rotation-based leveling osteotomy on ex vivo stifle joint stability following cranial cruciate ligament transection and medial meniscal release with and without a hamstring load. Vet Surg 2022; 51:940-951. [PMID: 35289413 PMCID: PMC9546295 DOI: 10.1111/vsu.13801] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 01/17/2022] [Accepted: 02/19/2022] [Indexed: 11/30/2022]
Abstract
Objective To evaluate the effect of center of rotation of angulation (CORA)‐based leveling osteotomy (CBLO) and hamstring load on stifle stability following cranial cruciate ligament transection (CCLx) and medial meniscal release (MMR). Study design Ex vivo experimental study. Sample population Cadaver hind limb preparations (n = 7). Methods After instrumentation, constant quadriceps and gastrocnemius loads with an optional hamstring load in a 3:1:0.6 ratio were applied, and stifles were extended from fully flexed using an electrical motor during fluoroscopic recording. The recording process was repeated after each of CCLx, MMR and CBLO and the extracted landmark coordinates were used for calculation of cranial tibial translation (CTT) and patellar ligament angle (PTA). Results Mean initial tibial plateau angle was 28.1°: post‐CBLO the mean was 9.7°. Cranial tibial translation developed from 50° and 75° with CCLx and MMR respectively (p < .04, < .02) without hamstring loading. Hamstring loading mitigated CTT due to CCLx and delayed CTT until 120° for MMR (P < .02) in this model. CBLO prevented CTT, except at 140° without hamstring loading (P = .01). Similar results were seen for PTA, but CBLO curves were parallel to and lower than intact values at all tested angles (P < .04), consistent with induced effective joint flexion. Conclusion CBLO to a target tibial plateau angle of 10° largely eliminated CTT induced by CCLx and MMR. Hamstring loads of 20% quadriceps load improved stifle stability in this model. Impact Stifle stability following CBLO appears to be multifactorial and depends on meniscal integrity, joint angle, and hamstring strength.
Collapse
Affiliation(s)
- Parisa Mazdarani
- Department of Veterinary Clinical Sciences, University of Copenhagen, Frederiksberg, Denmark
| | - Mir Sepehr Pedram
- Department of Surgery and Radiology, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
| | - James E Miles
- Department of Veterinary Clinical Sciences, University of Copenhagen, Frederiksberg, Denmark
| |
Collapse
|
6
|
Kinematics and kinetics comparison of ultra-congruent versus medial-pivot designs for total knee arthroplasty by multibody analysis. Sci Rep 2022; 12:3052. [PMID: 35197496 PMCID: PMC8866513 DOI: 10.1038/s41598-022-06909-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 02/08/2022] [Indexed: 12/18/2022] Open
Abstract
Nowadays, several configurations of total knee arthroplasty (TKA) implants are commercially available whose designs resulted from clinical and biomechanical considerations. Previous research activities led to the development of the so-called medial-pivot (MP) design. However, the actual benefits of the MP, with respect to other prosthesis designs, are still not well understood. The present work compares the impact of two insert geometries, namely the ultra-congruent (UC) and medial-pivot (MP), on the biomechanical behaviour of a bicondylar total knee endoprosthesis. For this purpose, a multibody model of a lower limb was created alternatively integrating the two implants having the insert geometry discretized. Joint dynamics and contact pressure distributions were evaluated by simulating a squat motion. Results showed a similar tibial internal rotation range of about 3.5°, but an early rotation occurs for the MP design. Furthermore, the discretization of the insert geometry allowed to efficiently derive the contact pressure distributions, directly within the multibody simulation framework, reporting peak pressure values of 33 MPa and 20 MPa for the UC and MP, respectively. Clinically, the presented findings confirm the possibility, through a MP design, to achieve a more natural joint kinematics, consequently improving the post-operative patient satisfaction and potentially reducing the occurrence of phenomena leading to the insert loosening.
Collapse
|
7
|
Terzini M, Aldieri A, Nurisso S, De Nisco G, Bignardi C. Finite Element Modeling Application in Forensic Practice: A Periprosthetic Femoral Fracture Case Study. Front Bioeng Biotechnol 2020; 8:619. [PMID: 32656199 PMCID: PMC7324477 DOI: 10.3389/fbioe.2020.00619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 05/20/2020] [Indexed: 11/13/2022] Open
Abstract
The incidence of periprosthetic fractures has rapidly increased in the last two decades and has been the cause of a large number of revision surgeries and permanent physical disability for many patients, as well as a significant socioeconomic burden for many nations. This research deals with a periprosthetic femur fracture real event, occurred following a total hip arthroplasty and treated with one of the most widespread internal fixation methods: the implant of a periprosthetic femur plate system. A Finite Element analysis was performed to investigate the implanted femur plate break after a short follow-up and to understand the plate break causes. Such events are currently object of forensic debate as more and more often hospitals, surgeons, and medical device manufacturers are denounced by patients to whom similar events occur. In this work, different load situations acting on the femur during daily and incidental activities were simulated, in order to validate the correct behavior of the plate, according to the intended use recommended by the manufacturer. The analysis demonstrates that the plate failure can occur in situations of unconventional loading such as that caused by stumbling and in presence of incomplete bone healing.
Collapse
Affiliation(s)
- Mara Terzini
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| | - Alessandra Aldieri
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| | - Stefania Nurisso
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| | - Giuseppe De Nisco
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| | - Cristina Bignardi
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| |
Collapse
|
8
|
Putame G, Pascoletti G, Terzini M, Zanetti EM, Audenino AL. Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs. Front Bioeng Biotechnol 2020; 8:557. [PMID: 32582675 PMCID: PMC7289914 DOI: 10.3389/fbioe.2020.00557] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Accepted: 05/07/2020] [Indexed: 11/13/2022] Open
Abstract
Intramedullary nails constitute a viable alternative to extramedullary fixation devices; their use is growing in recent years, especially with reference to self-locking nails. Different designs are available, and it is not trivial to foresee the respective in vivo performances and to provide clinical indications in relation to the type of bone and fracture. In this work a numerical methodology was set up and validated in order to compare the mechanical behavior of two new nailing device concepts with one already used in clinic. In detail, three different nails were studied: (1) the Marchetti-Vicenzi's nail (MV1), (2) a revised concept of this device (MV2), and (3) a new Terzini-Putame's nail (TP) concept. Firstly, the mechanical behavior of the MV1 device was assessed through experimental loading tests employing a 3D-printed component aimed at reproducing the bone geometry inside which the device is implanted. In the next step, the respective numerical model was created, based on a multibody approach including flexible parts, and this model was validated against the previously obtained experimental results. Finally, numerical models of the MV2 and TP concepts were implemented and compared with the MV1 nail, focusing the attention on the response of all devices to compression, tension, bending, and torsion. A stability index (SI) was defined to quantify the mechanical stability provided to the nail-bone assembly by the elastic self-locking mechanism for the various loading conditions. In addition, results in terms of nail-bone assembly stiffness, computed from force/moment vs. displacement/rotation curves, were presented and discussed. Findings revealed that numerical models were able to provide good estimates of load vs. displacement curves. The TP nail concept proved to be able to generate a significantly higher SI (27 N for MV1 vs. 380 N for TP) and a greater stiffening action (up to a stiffness difference for bending load that ranges from 370 Nmm/° for MV1 to 1,532 Nmm/° for TP) than the other two devices which showed similar performances. On the whole, a demonstration was given of information which can be obtained from numerical simulations of expandable fixation devices.
Collapse
Affiliation(s)
- Giovanni Putame
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
- PolitoMed Lab, Politecnico di Torino, Turin, Italy
| | | | - Mara Terzini
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
- PolitoMed Lab, Politecnico di Torino, Turin, Italy
| | | | - Alberto L. Audenino
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
- PolitoMed Lab, Politecnico di Torino, Turin, Italy
| |
Collapse
|
9
|
Xiong B, Zeng N, Li Y, Du M, Huang M, Shi W, Mao G, Yang Y. Determining the Online Measurable Input Variables in Human Joint Moment Intelligent Prediction Based on the Hill Muscle Model. SENSORS 2020; 20:s20041185. [PMID: 32098065 PMCID: PMC7070854 DOI: 10.3390/s20041185] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 02/19/2020] [Accepted: 02/19/2020] [Indexed: 01/06/2023]
Abstract
Introduction: Human joint moment is a critical parameter to rehabilitation assessment and human-robot interaction, which can be predicted using an artificial neural network (ANN) model. However, challenge remains as lack of an effective approach to determining the input variables for the ANN model in joint moment prediction, which determines the number of input sensors and the complexity of prediction. Methods: To address this research gap, this study develops a mathematical model based on the Hill muscle model to determining the online input variables of the ANN for the prediction of joint moments. In this method, the muscle activation, muscle-tendon moment velocity and length in the Hill muscle model and muscle-tendon moment arm are translated to the online measurable variables, i.e. muscle electromyography (EMG), joint angles and angular velocities of the muscle span. To test the predictive ability of these input variables, an ANN model is designed and trained to predict joint moments. The ANN model with the online measurable input variables is tested on the experimental data collected from ten healthy subjects running with the speeds of 2, 3, 4 and 5 m/s on a treadmill. The variance accounted for (VAF) between the predicted and inverse dynamics moment is used to evaluate the prediction accuracy. Results: The results suggested that the method can predict joint moments with a higher accuracy (mean VAF = 89.67±5.56 %) than those obtained by using other joint angles and angular velocities as inputs (mean VAF = 86.27±6.6%) evaluated by jack-knife cross-validation. Conclusions: The proposed method provides us with a powerful tool to predict joint moment based on online measurable variables, which establishes the theoretical basis for optimizing the input sensors and detection complexity of the prediction system. It may facilitate the research on exoskeleton robot control and real-time gait analysis in motor rehabilitation.
Collapse
Affiliation(s)
- Baoping Xiong
- College of Physics and Information Engineering, Fuzhou University, Fuzhou City 350116, Fujian Province, China; (B.X.); (M.H.); (W.S.)
- Department of Mathematics and Physics, Fujian University of Technology, Fuzhou City 350118, Fujian Province, China;
| | - Nianyin Zeng
- Department of Instrumental and Electrical Engineering, Xiamen University, Fujian 361005, China
- Correspondence: (N.Z.); (M.D.); (Y.Y.)
| | - Yurong Li
- Fujian Key Laboratory of Medical Instrumentation & Pharmaceutical Technology, Fuzhou University, Fuzhou City 350116, Fujian Province, China;
| | - Min Du
- College of Physics and Information Engineering, Fuzhou University, Fuzhou City 350116, Fujian Province, China; (B.X.); (M.H.); (W.S.)
- Fujian provincial key laboratory of eco-industrial green technology, Wuyi University, Wuyishan City 354300, Fujian Province, China
- Correspondence: (N.Z.); (M.D.); (Y.Y.)
| | - Meilan Huang
- College of Physics and Information Engineering, Fuzhou University, Fuzhou City 350116, Fujian Province, China; (B.X.); (M.H.); (W.S.)
| | - Wuxiang Shi
- College of Physics and Information Engineering, Fuzhou University, Fuzhou City 350116, Fujian Province, China; (B.X.); (M.H.); (W.S.)
| | - Guojun Mao
- Department of Mathematics and Physics, Fujian University of Technology, Fuzhou City 350118, Fujian Province, China;
| | - Yuan Yang
- Department of Physical Therapy and Human Movement Sciences, Northwestern University, Chicago, IL 60208, USA
- Correspondence: (N.Z.); (M.D.); (Y.Y.)
| |
Collapse
|
10
|
Pascoletti G, Catelani D, Conti P, Cianetti F, Zanetti EM. Multibody Models for the Analysis of a Fall From Height: Accident, Suicide, or Murder? Front Bioeng Biotechnol 2019; 7:419. [PMID: 31921822 PMCID: PMC6920173 DOI: 10.3389/fbioe.2019.00419] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Accepted: 11/29/2019] [Indexed: 11/13/2022] Open
Abstract
The final subject position is often the only evidence in the case of the fall of a human being from a given height. Foreseeing the body trajectory and the respective driving force may not be trivial due to the possibility of rotations and to an unknown initial position and momentum of the subject. This article illustrates how multibody models can be used for this aim, with specific reference to an actual case, where a worker fell into a stair well, prior to stair mounting, and he was found in an unexpected posture. The aim of the analysis was establishing if this worker was dead in that same place, if he had been pushed, and which was his initial position. A multibody model of the subject has been built ("numerical android"), given his stature and his known mass. Multiple simulations have been performed, following a design of experiments where various initial positions and velocity as well as pushing forces have been considered, while the objective function to be minimized was the deviation of the numerical android position from the actual worker position. At the end of the analysis, it was possible to point how a very limited set of conditions, all including the application of an external pushing force (or initial speed), could produce the given final posture with an error on the distance function equal to 0.39 m. The full analysis gives a demonstration of the potentiality of multibody models as a tool for the analysis of falls in forensic inquiries.
Collapse
Affiliation(s)
| | | | - Paolo Conti
- Department of Engineering, University of Perugia, Perugia, Italy
| | - Filippo Cianetti
- Department of Engineering, University of Perugia, Perugia, Italy
| | | |
Collapse
|