1
|
Li Q, Sun Y, Zhao H, Zhang F, Guo Y, Chen X, Zhao G. Structure and properties of the acellular porcine cornea irradiated with 60Co-γ and electron beam and its histocompatibility. J Biomed Mater Res A 2024; 112:825-840. [PMID: 38158889 DOI: 10.1002/jbm.a.37663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 08/15/2023] [Accepted: 12/18/2023] [Indexed: 01/03/2024]
Abstract
Acellular porcine cornea (APC) has been used in corneal transplantation and treatment of the corneal diseases. Sterilization is a key step before the application of graft, and irradiation is one of the most commonly used methods. In this paper, APC was prepared by the physical freeze-thawing combined with biological enzymes, and the effects of the electron beam (E-beam) and cobalt 60 (60Co-γ) at the dose of 15 kGy on the physicochemical properties, structure, immunogenicity, and biocompatibility of the APC were investigated. After decellularization, the residual DNA was 20.86 ± 1.02 ng/mg, and the α-Gal clearance rate was more than 99%. Irradiation, especially the 60Co-γ, reduced the cornea's transmittance, elastic modulus, enzymatic hydrolysis rate, swelling ratio, and cross-linking degree. Meanwhile, the diameter and spacing of the collagen fibers increased. In the rat subcutaneous implantation, many inflammatory cells appeared in the unirradiated APC, while the irradiated had good histocompatibility, but the degradation was faster. The lamellar keratoplasty in rabbits indicated that compared to the E-beam, the 60Co-γ damaged the chemical bond of collagen to a larger extent, reduced the content of GAGs, and prolonged the complete epithelization of the grafts. The corneal edema was more serious within 1 month after the surgery. After 2 months, the thickness of the APC with the two irradiation methods tended to be stable, but that in the 60Co-γ group became thinner. The pathological results showed that the collagen structure was looser and the pores were larger, indicating the 60Co-γ had a more extensive effect on the APC than the E-beam at 15 kGy.
Collapse
Affiliation(s)
- Qing Li
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Yajun Sun
- Qingdao Chunghao Tissue Engineering Co., Ltd., Qingdao, Shandong, China
| | - Haibin Zhao
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Fan Zhang
- Qilu Hospital, Shandong University, Jinan, Shandong, China
| | - Yu Guo
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Xin Chen
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Guoqun Zhao
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| |
Collapse
|
2
|
Li Q, Sun Y, Zhao H, Gao Z, Zhai D. Structure and properties of the acellular porcine cornea irradiated with electron beam and its in-situ implantation. J Biomed Mater Res B Appl Biomater 2023; 111:2013-2024. [PMID: 37477184 DOI: 10.1002/jbm.b.35301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 05/15/2023] [Accepted: 07/07/2023] [Indexed: 07/22/2023]
Abstract
Different sterilization doses of the electron beam (E-beam) will change the properties of biomaterials and affect their clinical application. Acellular porcine cornea (APC) is a promising corneal substitute to alleviate the shortage of corneal resources. The residual DNA was significantly reduced to 18.50 ± 3.19 ng/mg, and the clearance rate of α-Gal was close to 100% after the treatment with freezing-thawing combined enzyme, indicating that the decellularization was effective. The effects of different E-beam doses at 0, 2, 8, 15, and 25 kGy on the APC were studied. With the increase in irradiation dose, the transmittance, tensile strength, and swelling ratio of APC gradually decreased, but the resistance to enzymatic degradation was stronger than that of non-irradiated APC, especially at 8 kGy. The structure of APC was denser after irradiation, but the dose of 25 kGy could cause partial collagen fiber fracture and increase the pore size. The cell viability of the APC irradiated by 15 and 25 kGy were greater than 80%. After the implantation in rabbit corneas, there was no obvious neovascularization and inflammation, but the dose of 25 kGy had a more destructive effect on the chemical bonds of collagen, which made the APC easier to be degraded. The thickness of APC in the 25 kGy group was thinner than that in the 15 kGy group 1 year after surgery, and the epithelium grew more slowly, so the E-beam dose of 15 kGy might be more suitable for the sterilization of APC.
Collapse
Affiliation(s)
- Qing Li
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Yajun Sun
- Research and Development Center, Qingdao Chunghao Tissue Engineering Co., Ltd., Qingdao, Shandong, China
| | - Haibin Zhao
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Zhiyong Gao
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| | - Dongjie Zhai
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China
| |
Collapse
|
3
|
Thirunavukarasu AJ, Han E, Nedumaran AM, Kurz AC, Shuman J, Yusoff NZBM, Liu YC, Foo V, Czarny B, Riau AK, Mehta JS. Electron beam-irradiated donor cornea for on-demand lenticule implantation to treat corneal diseases and refractive error. Acta Biomater 2023; 169:334-347. [PMID: 37532130 DOI: 10.1016/j.actbio.2023.07.053] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 07/07/2023] [Accepted: 07/26/2023] [Indexed: 08/04/2023]
Abstract
The cornea is the major contributor to the refractive power of the eye, and corneal diseases are a leading cause of reversible blindness. The main treatment for advanced corneal disease is keratoplasty: allograft transplantation of the cornea. Examples include lenticule implantation to treat corneal disorders (e.g. keratoconus) or correct refractive errors. These procedures are limited by the shelf-life of the corneal tissue, which must be discarded within 2-4 weeks. Electron-beam irradiation is an emerging sterilisation technique, which extends this shelf life to 2 years. Here, we produced lenticules from fresh and electron-beam (E-beam) irradiated corneas to establish a new source of tissue for lenticule implantation. In vitro, in vivo, and ex vivo experiments were conducted to compare fresh and E-beam-irradiated lenticules. Results were similar in terms of cutting accuracy, ultrastructure, optical transparency, ease of extraction and transplantation, resilience to mechanical handling, biocompatibility, and post-transplant wound healing process. Two main differences were noted. First, ∼59% reduction of glycosaminoglycans resulted in greater compression of E-beam-irradiated lenticules post-transplant, likely due to reduced corneal hydration-this appeared to affect keratometry after implantation. Cutting a thicker lenticule would be required to ameliorate the difference in refraction. Second, E-beam-sterilised lenticules exhibited lower Young's modulus which may indicate greater care with handling, although no damage or perforation was caused in our procedures. In summary, E-beam-irradiated corneas are a viable source of tissue for stromal lenticules, and may facilitate on-demand lenticule implantation to treat a wide range of corneal diseases. Our study suggested that its applications in human patients are warranted. STATEMENT OF SIGNIFICANCE: Corneal blindness affects over six million patients worldwide. For patients requiring corneal transplantation, current cadaver-based procedures are limited by the short shelf-life of donor tissue. Electron-beam (E-beam) sterilisation extends this shelf-life from weeks to years but there are few published studies of its use. We demonstrated that E-beam-irradiated corneas are a viable source of lenticules for implantation. We conducted in vitro, in vivo, and ex vivo comparisons of E-beam and fresh corneal lenticules. The only differences exhibited by E-beam-treated lenticules were reduced expression of glycosaminoglycans, resulting in greater tissue compression and lower refraction suggesting that a thicker cut is required to achieve the same optical and refractive outcome; and lower Young's modulus indicating extra care with handling.
Collapse
Affiliation(s)
- Arun J Thirunavukarasu
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; University of Cambridge School of Clinical Medicine, Cambridge, United Kingdom
| | - Evelina Han
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
| | - Anu Maashaa Nedumaran
- School of Materials Science and Engineering, Nanyang Technological University, Singapore
| | | | | | | | - Yu-Chi Liu
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore
| | - Valencia Foo
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; Singapore National Eye Centre, Singapore
| | - Bertrand Czarny
- School of Materials Science and Engineering, Nanyang Technological University, Singapore
| | - Andri K Riau
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; Ophthalmology and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore.
| | - Jodhbir S Mehta
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; School of Materials Science and Engineering, Nanyang Technological University, Singapore; Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore.
| |
Collapse
|