1
|
Le JV, Mendes JK, Sideris K, Bieging E, Carter S, Stehlik J, DiBella EVR, Adluru G. Free-Breathing Ungated Radial Simultaneous Multi-Slice Cardiac T1 Mapping. J Magn Reson Imaging 2025; 61:2587-2600. [PMID: 39661447 PMCID: PMC12063770 DOI: 10.1002/jmri.29676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 11/25/2024] [Accepted: 11/26/2024] [Indexed: 12/13/2024] Open
Abstract
BACKGROUND Modified Look-Locker imaging (MOLLI) T1 mapping sequences are acquired during breath-holding and require ECG gating with consistent R-R intervals, which is problematic for patients with atrial fibrillation (AF). Consequently, there is a need for a free-breathing and ungated framework for cardiac T1 mapping. PURPOSE To develop and evaluate a free-breathing ungated radial simultaneous multi-slice (SMS) cardiac T1 mapping (FURST) framework. STUDY TYPE Retrospective, nonconsecutive cohort study. POPULATION Twenty-four datasets from 17 canine and 7 human subjects (4 males, 51 ± 22 years; 3 females, 56 ± 19 years). Canines were from studies involving AF induction and ablation treatment. The human population included separate subjects with suspected microvascular disease, acute coronary syndrome with persistent AF, and transthyretin amyloidosis with persistent AF. The remaining human subjects were healthy volunteers. FIELD STRENGTH/SEQUENCE Pre- and post-contrast T1 mapping with the free-breathing and ungated SMS inversion recovery sequence with gradient echo readout and with conventional MOLLI sequences at 1.5 T and 3.0 T. ASSESSMENT MOLLI and FURST were acquired in all subjects, and American Heart Association (AHA) segmentation was used for segment-wise analysis. Pre-contrast T1, post-contrast T1, and ECV were analyzed using correlation and Bland-Altman plots in 13 canines and 7 human subjects. T1 difference box plots for repeated acquisitions in four canine subjects were used to assess reproducibility. The PIQUE image quality metric was used to evaluate the perceptual quality of T1 maps. STATISTICAL TESTS Paired t-tests were used for all comparisons between FURST and MOLLI, with P < 0.05 indicating statistical significance. RESULTS There were no significant differences between FURST and MOLLI pre-contrast T1 reproducibility ( 25 ± 18 and 19 ± 16 msec , P = 0.19 ), FURST and MOLLI ECV ( 29 % ± 11 % and 28 % ± 11 % , P = 0.05 ), or FURST and MOLLI PIQUE scores ( 52 ± 8 and 53 ± 10 , P = 0.18 ). The ECV mean difference was 0.48 with 95 % CI : 6.0 × 10 - 4 , 0.96 . CONCLUSIONS FURST had similar quality pre-contrast T1, post-contrast T1, and ECV maps and similar reproducibility compared to MOLLI. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY: 1.
Collapse
Affiliation(s)
- Johnathan V. Le
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging SciencesUniversity of UtahSalt Lake CityUtahUSA
- Department of Biomedical EngineeringUniversity of UtahSalt Lake CityUtahUSA
| | - Jason K. Mendes
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging SciencesUniversity of UtahSalt Lake CityUtahUSA
| | | | - Erik Bieging
- Department of CardiologyUniversity of UtahSalt Lake CityUtahUSA
| | - Spencer Carter
- Department of CardiologyUniversity of UtahSalt Lake CityUtahUSA
| | - Josef Stehlik
- Department of CardiologyUniversity of UtahSalt Lake CityUtahUSA
| | - Edward V. R. DiBella
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging SciencesUniversity of UtahSalt Lake CityUtahUSA
- Department of Biomedical EngineeringUniversity of UtahSalt Lake CityUtahUSA
| | - Ganesh Adluru
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging SciencesUniversity of UtahSalt Lake CityUtahUSA
- Department of Biomedical EngineeringUniversity of UtahSalt Lake CityUtahUSA
| |
Collapse
|
2
|
Lee W, Han PK, Marin T, Mounime IB, Vafay Eslahi S, Djebra Y, Chi D, Bijari FJ, Normandin MD, El Fakhri G, Ma C. Free-breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model. Magn Reson Med 2025; 93:536-549. [PMID: 39402014 PMCID: PMC11606777 DOI: 10.1002/mrm.30284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 07/27/2024] [Accepted: 08/20/2024] [Indexed: 10/23/2024]
Abstract
PURPOSE To develop a new method for free-breathing 3D extracellular volume (ECV) mapping of the whole heart at 3 T. METHODS A free-breathing 3D cardiac ECV mapping method was developed at 3 T. T1 mapping was performed before and after contrast agent injection using a free-breathing electrocardiogram-gated inversion recovery sequence with spoiled gradient echo readout. A linear tangent space alignment model-based method was used to reconstruct high-frame-rate dynamic images from (k,t)-space data sparsely sampled along a random stack-of-stars trajectory. Joint T1 and transmit B1 estimation were performed voxel-by-voxel for pre- and post-contrast T1 mapping. To account for the time-varying T1 after contrast agent injection, a linearly time-varying T1 model was introduced for post-contrast T1 mapping. ECV maps were generated by aligning pre- and post-contrast T1 maps through affine transformation. RESULTS The feasibility of the proposed method was demonstrated using in vivo studies with six healthy volunteers at 3 T. We obtained 3D ECV maps at a spatial resolution of 1.9 × 1.9 × 4.5 mm3 and a FOV of 308 × 308 × 144 mm3, with a scan time of 10.1 ± 1.4 and 10.6 ± 1.6 min before and after contrast agent injection, respectively. The ECV maps and the pre- and post-contrast T1 maps obtained by the proposed method were in good agreement with the 2D MOLLI method both qualitatively and quantitatively. CONCLUSION The proposed method allows for free-breathing 3D ECV mapping of the whole heart within a practically feasible imaging time. The estimated ECV values from the proposed method were comparable to those from the existing method.
Collapse
Affiliation(s)
- Wonil Lee
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| | - Paul Kyu Han
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| | - Thibault Marin
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| | - Ismaël B.G. Mounime
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
- LTCI, Télécom Paris, Institut Polytechnique de Paris, France
| | - Samira Vafay Eslahi
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Yanis Djebra
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| | - Didi Chi
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| | - Felicitas J. Bijari
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| | - Marc D. Normandin
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| | - Georges El Fakhri
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| | - Chao Ma
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, USA
| |
Collapse
|
3
|
Emu Y, Chen Y, Chen Z, Gao J, Yuan J, Lu H, Jin H, Hu C. Simultaneous multislice cardiac multimapping based on locally low-rank and sparsity constraints. J Cardiovasc Magn Reson 2024; 26:101125. [PMID: 39547314 DOI: 10.1016/j.jocmr.2024.101125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Revised: 09/29/2024] [Accepted: 11/07/2024] [Indexed: 11/17/2024] Open
Abstract
BACKGROUND Although quantitative myocardial T1 and T2 mappings are clinically used to evaluate myocardial diseases, their application needs a minimum of six breath-holds to cover three short-axis slices. The purpose of this work is to simultaneously quantify multislice myocardial T1 and T2 across three short-axis slices in one breath-hold by combining simultaneous multislice (SMS) with multimapping. METHODS An SMS-Multimapping sequence with multiband radiofrequency (RF) excitations and Cartesian fast low-angle shot readouts was developed for data acquisition. When 3 slices are simultaneously acquired, the acceleration rate is around 12-fold, causing a highly ill-conditioned reconstruction problem. To mitigate image artifacts and noise caused by the ill-conditioning, a reconstruction algorithm based on locally low-rank and sparsity (LLRS) constraints was developed. Validation was performed in phantoms and in vivo imaging, with 20 healthy subjects and 4 patients, regarding regional mean, precision, and scan-rescan reproducibility. RESULTS The phantom imaging shows that SMS-Multimapping with locally low-rank (LLRS) accurately reconstructed multislice T1 and T2 maps despite a six-fold acceleration of scan time. Healthy subject imaging shows that the proposed LLRS algorithm substantially improved image quality relative to split slice-generalized autocalibrating partially parallel acquisition. Compared with modified look-locker inversion recovery (MOLLI), SMS-Multimapping exhibited higher T1 mean (1118 ± 43 ms vs 1190 ± 49 ms, P < 0.01), lower precision (67 ± 17 ms vs 90 ± 17 ms, P < 0.01), and acceptable scan-rescan reproducibility measured by 2 scans 10-min apart (bias = 1.4 ms for MOLLI and 9.0 ms for SMS-Multimapping). Compared with balanced steady-state free precession (bSSFP) T2 mapping, SMS-Multimapping exhibited similar T2 mean (43.5 ± 3.3 ms vs 43.0 ± 3.5 ms, P = 0.64), similar precision (4.9 ± 2.1 ms vs 5.1 ± 1.0 ms, P = 0.93), and acceptable scan-rescan reproducibility (bias = 0.13 ms for bSSFP T2 mapping and 0.55 ms for SMS-Multimapping). In patients, SMS-Multimapping clearly showed the abnormality in a similar fashion as the reference methods despite using only one breath-hold. CONCLUSION SMS-Multimapping with the proposed LLRS reconstruction can measure multislice T1 and T2 maps in one breath-hold with good accuracy, reasonable precision, and acceptable reproducibility, achieving a six-fold reduction of scan time and an improvement of patient comfort.
Collapse
Affiliation(s)
- Yixin Emu
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yinyin Chen
- Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Medical Imaging Institute, Shanghai, China
| | - Zhuo Chen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Juan Gao
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jianmin Yuan
- Central Research Institute, UIH Group, Shanghai, China
| | - Hongfei Lu
- Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Medical Imaging Institute, Shanghai, China
| | - Hang Jin
- Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Medical Imaging Institute, Shanghai, China
| | - Chenxi Hu
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
4
|
Rashid I, Lima da Cruz G, Seiberlich N, Hamilton JI. Cardiac MR Fingerprinting: Overview, Technical Developments, and Applications. J Magn Reson Imaging 2024; 60:1753-1773. [PMID: 38153855 PMCID: PMC11211246 DOI: 10.1002/jmri.29206] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/13/2023] [Accepted: 12/14/2023] [Indexed: 12/30/2023] Open
Abstract
Cardiovascular magnetic resonance (CMR) is an established imaging modality with proven utility in assessing cardiovascular diseases. The ability of CMR to characterize myocardial tissue using T1- and T2-weighted imaging, parametric mapping, and late gadolinium enhancement has allowed for the non-invasive identification of specific pathologies not previously possible with modalities like echocardiography. However, CMR examinations are lengthy and technically complex, requiring multiple pulse sequences and different anatomical planes to comprehensively assess myocardial structure, function, and tissue composition. To increase the overall impact of this modality, there is a need to simplify and shorten CMR exams to improve access and efficiency, while also providing reproducible quantitative measurements. Multiparametric MRI techniques that measure multiple tissue properties offer one potential solution to this problem. This review provides an in-depth look at one such multiparametric approach, cardiac magnetic resonance fingerprinting (MRF). The article is structured as follows. First, a brief review of single-parametric and (non-Fingerprinting) multiparametric CMR mapping techniques is presented. Second, a general overview of cardiac MRF is provided covering pulse sequence implementation, dictionary generation, fast k-space sampling methods, and pattern recognition. Third, recent technical advances in cardiac MRF are covered spanning a variety of topics, including simultaneous multislice and 3D sampling, motion correction algorithms, cine MRF, synthetic multicontrast imaging, extensions to measure additional clinically important tissue properties (proton density fat fraction, T2*, and T1ρ), and deep learning methods for image reconstruction and parameter estimation. The last section will discuss potential clinical applications, concluding with a perspective on how multiparametric techniques like MRF may enable streamlined CMR protocols. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Imran Rashid
- Department of Radiology, University of Michigan, Ann Arbor, MI, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Gastao Lima da Cruz
- School of Medicine, Case Western Reserve University, Cleveland, OH, USA
- Harrington Heart and Vascular Institute, University Hospitals, Cleveland, OH, USA
| | - Nicole Seiberlich
- School of Medicine, Case Western Reserve University, Cleveland, OH, USA
- Harrington Heart and Vascular Institute, University Hospitals, Cleveland, OH, USA
| | - Jesse I. Hamilton
- School of Medicine, Case Western Reserve University, Cleveland, OH, USA
- Harrington Heart and Vascular Institute, University Hospitals, Cleveland, OH, USA
| |
Collapse
|
5
|
Cao T, Hu Z, Mao X, Chen Z, Kwan AC, Xie Y, Berman DS, Li D, Christodoulou AG. Alternating low-rank tensor reconstruction for improved multiparametric mapping with cardiovascular MR Multitasking. Magn Reson Med 2024; 92:1421-1439. [PMID: 38726884 PMCID: PMC11262969 DOI: 10.1002/mrm.30131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 03/20/2024] [Accepted: 04/08/2024] [Indexed: 05/15/2024]
Abstract
PURPOSE To develop a novel low-rank tensor reconstruction approach leveraging the complete acquired data set to improve precision and repeatability of multiparametric mapping within the cardiovascular MR Multitasking framework. METHODS A novel approach that alternated between estimation of temporal components and spatial components using the entire data set acquired (i.e., including navigator data and imaging data) was developed to improve reconstruction. The precision and repeatability of the proposed approach were evaluated on numerical simulations, 10 healthy subjects, and 10 cardiomyopathy patients at multiple scan times for 2D myocardial T1/T2 mapping with MR Multitasking and were compared with those of the previous navigator-derived fixed-basis approach. RESULTS In numerical simulations, the proposed approach outperformed the previous fixed-basis approach with lower T1 and T2 error against the ground truth at all scan times studied and showed better motion fidelity. In human subjects, the proposed approach showed no significantly different sharpness or T1/T2 measurement and significantly improved T1 precision by 20%-25%, T2 precision by 10%-15%, T1 repeatability by about 30%, and T2 repeatability by 25%-35% at 90-s and 50-s scan times The proposed approach at the 50-s scan time also showed comparable results with that of the previous fixed-basis approach at the 90-s scan time. CONCLUSION The proposed approach improved precision and repeatability for quantitative imaging with MR Multitasking while maintaining comparable motion fidelity, T1/T2 measurement, and septum sharpness and had the potential for further reducing scan time from 90 s to 50 s.
Collapse
Affiliation(s)
- Tianle Cao
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| | - Zheyuan Hu
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| | - Xianglun Mao
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Zihao Chen
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| | - Alan C. Kwan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Departments of Imaging and Cardiology, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Yibin Xie
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Daniel S. Berman
- Departments of Imaging and Cardiology, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Debiao Li
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| | - Anthony G. Christodoulou
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| |
Collapse
|
6
|
Hua A, Velasco C, Munoz C, Milotta G, Fotaki A, Bosio F, Granlund I, Sularz A, Chiribiri A, Kunze KP, Botnar R, Prieto C, Ismail TF. Evaluation of myocarditis with a free-breathing three-dimensional isotropic whole-heart joint T1 and T2 mapping sequence. J Cardiovasc Magn Reson 2024; 26:101100. [PMID: 39306195 PMCID: PMC11638600 DOI: 10.1016/j.jocmr.2024.101100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 09/11/2024] [Accepted: 09/13/2024] [Indexed: 11/30/2024] Open
Abstract
BACKGROUND The diagnosis of myocarditis by cardiovascular magnetic resonance (CMR) requires the use of T2 and T1 weighted imaging, ideally incorporating parametric mapping. Current two-dimensional (2D) mapping sequences are acquired sequentially and involve multiple breath-holds resulting in prolonged scan times and anisotropic image resolution. We developed an isotropic free-breathing three-dimensional (3D) whole-heart sequence that allows simultaneous T1 and T2 mapping and validated it in patients with suspected myocarditis. METHODS Eighteen healthy volunteers and 28 patients with suspected myocarditis underwent conventional 2D T1 and T2 mapping with whole-heart coverage and 3D joint T1/T2 mapping on a 1.5T scanner. Acquisition time, image quality, and diagnostic performance were compared. Qualitative analysis was performed using a 4-point Likert scale. Bland-Altman plots were used to assess the quantitative agreement between 2D and 3D sequences. RESULTS The 3D T1/T2 sequence was acquired in 8 min 26 s under free breathing, whereas 2D T1 and T2 sequences were acquired with breath-holds in 11 min 44 s (p = 0.0001). All 2D images were diagnostic. For 3D images, 89% (25/28) of T1 and 96% (27/28) of T2 images were diagnostic with no significant difference in the proportion of diagnostic images for the 3D and 2D T1 (p = 0.2482) and T2 maps (p = 1.0000). Systematic bias in T1 was noted with biases of 102, 115, and 152 ms for basal-apical segments, with a larger bias for higher T1 values. Good agreement between T2 values for 3D and 2D techniques was found (bias of 1.8, 3.9, and 3.6 ms for basal-apical segments). The sensitivity and specificity of the 3D sequence for diagnosing acute myocarditis were 74% (95% confidence interval [CI] 49%-91%) and 83% (36%-100%), respectively, with a c-statistic (95% CI) of 0.85 (0.79-0.91) and no statistically significant difference between the 2D and 3D sequences for the detection of acute myocarditis for T1 (p = 0.2207) or T2 (p = 1.0000). CONCLUSION Free-breathing whole-heart 3D joint T1/T2 mapping was comparable to 2D mapping sequences with respect to diagnostic performance, but with the added advantages of free breathing and shorter scan times. Further work is required to address the bias noted at high T1 values, but this did not significantly impact diagnostic accuracy.
Collapse
Affiliation(s)
- Alina Hua
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; Cardiology Department, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Carlos Velasco
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Camila Munoz
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Giorgia Milotta
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Anastasia Fotaki
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Filippo Bosio
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Inka Granlund
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Agata Sularz
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Amedeo Chiribiri
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Karl P Kunze
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; MR Research Collaborations, Siemens Healthcare Limited, Camberley, United Kingdom
| | - Rene Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Institute of Advanced Study, Munich, Germany; Technical University of Munich, Munich, Germany
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile
| | - Tevfik F Ismail
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; Cardiology Department, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom.
| |
Collapse
|
7
|
Guan X, Yang HJ, Zhang X, Wang N, Han H, Tang R, Hu Z, Youssef K, Vora K, Krishnam MS, Christodoulou AG, Li D, Sharif B, Dharmakumar R. Non-electrocardiogram-gated, free-breathing, off-resonance reduced, high-resolution, whole-heart myocardial T 2 * mapping at 3 T within 5 min. Magn Reson Med 2024; 91:1936-1950. [PMID: 38174593 DOI: 10.1002/mrm.29968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 11/21/2023] [Accepted: 11/26/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE Widely used conventional 2D T2 * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T2 * technique that enables rapid whole-heart coverage was developed and validated. METHODS A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T2 * imaging. This approach was tested in healthy human volunteers and in swine before and after intravenous administration of ferumoxytol. RESULTS Spatial-resolution matched T2 * images were acquired with 2-3-fold reduction in scan time using the proposed T2 * mapping approach relative to conventional T2 * mapping. Compared with the conventional approach, T2 * images acquired with the proposed method demonstrated reduced off-resonance and flow artifacts, leading to higher image quality and lower coefficient of variation in T2 *-weighted images of the myocardium of swine and humans. Mean myocardial T2 * values determined using the proposed and conventional approaches were highly correlated and showed minimal bias. CONCLUSION The proposed non-ECG-gated, free-breathing, 3D T2 * imaging approach can be performed within 5 min or less. It can overcome critical image artifacts from undesirable cardiac and respiratory motion and bulk off-resonance shifts at the heart-lung interface. The proposed approach is expected to facilitate faster and improved cardiac T2 * mapping in those with limited breath-holding capacity or arrhythmias.
Collapse
Affiliation(s)
- Xingmin Guan
- Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Hsin-Jung Yang
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Xinheng Zhang
- Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA
| | - Nan Wang
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Hui Han
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Richard Tang
- Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Zhehao Hu
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Khalid Youssef
- Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Keyur Vora
- Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Mayil S Krishnam
- Department of Radiology, Stanford University, Palo Alto, California, USA
| | - Anthony G Christodoulou
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
| | - Debiao Li
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA
| | - Behzad Sharif
- Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Rohan Dharmakumar
- Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA
| |
Collapse
|
8
|
Zhang Y, Ye Z, Xia C, Tan Y, Zhang M, Lv X, Tang J, Li Z. Clinical Applications and Recent Updates of Simultaneous Multi-slice Technique in Accelerated MRI. Acad Radiol 2024; 31:1976-1988. [PMID: 38220568 DOI: 10.1016/j.acra.2023.12.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 01/16/2024]
Abstract
Simultaneous multi-slice (SMS) is a magnetic resonance imaging (MRI) acceleration technique that utilizes multi-band radio-frequency pulses to simultaneously excite and encode multiple slices. Currently, SMS has been widely studied and applied in the MRI examination to reduce acquisition time, which can significantly improve the examination efficiency and patient throughput. Moreover, SMS technique can improve spatial resolution, which is of great value in disease diagnosis, treatment response monitoring, and prognosis prediction. This review will briefly introduce the technical principles of SMS, and summarize its current clinical applications. More importantly, we will discuss the recent technical progress and future research direction of SMS, hoping to highlight the clinical value and scientific potential of this technique.
Collapse
Affiliation(s)
- Yiteng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zheng Ye
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Chunchao Xia
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Yuqi Tan
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Meng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Xinyang Lv
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Jing Tang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
9
|
Christodoulou AG, Cruz G, Arami A, Weingärtner S, Artico J, Peters D, Seiberlich N. The future of cardiovascular magnetic resonance: All-in-one vs. real-time (Part 1). J Cardiovasc Magn Reson 2024; 26:100997. [PMID: 38237900 PMCID: PMC11211239 DOI: 10.1016/j.jocmr.2024.100997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 01/10/2024] [Indexed: 02/26/2024] Open
Abstract
Cardiovascular magnetic resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR. To this end, the vision of each is described, along with techniques which have been devised and tested along the pathway of clinical implementation. The pros and cons of the different methods are presented, and the remaining open needs of each are detailed. Part 1 will tackle the "all-in-one" approaches, and Part 2 the "real-time" approaches along with an overall summary of these emerging methods.
Collapse
Affiliation(s)
- Anthony G Christodoulou
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, USA; Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Gastao Cruz
- Michigan Institute for Imaging Technology and Translation, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | - Ayda Arami
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands; Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | | | - Dana Peters
- Radiology & Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Nicole Seiberlich
- Michigan Institute for Imaging Technology and Translation, Department of Radiology, University of Michigan, Ann Arbor, MI, USA.
| |
Collapse
|
10
|
Sheagren CD, Cao T, Patel JH, Chen Z, Lee HL, Wang N, Christodoulou AG, Wright GA. Motion-compensated T 1 mapping in cardiovascular magnetic resonance imaging: a technical review. Front Cardiovasc Med 2023; 10:1160183. [PMID: 37790594 PMCID: PMC10542904 DOI: 10.3389/fcvm.2023.1160183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 08/22/2023] [Indexed: 10/05/2023] Open
Abstract
T 1 mapping is becoming a staple magnetic resonance imaging method for diagnosing myocardial diseases such as ischemic cardiomyopathy, hypertrophic cardiomyopathy, myocarditis, and more. Clinically, most T 1 mapping sequences acquire a single slice at a single cardiac phase across a 10 to 15-heartbeat breath-hold, with one to three slices acquired in total. This leaves opportunities for improving patient comfort and information density by acquiring data across multiple cardiac phases in free-running acquisitions and across multiple respiratory phases in free-breathing acquisitions. Scanning in the presence of cardiac and respiratory motion requires more complex motion characterization and compensation. Most clinical mapping sequences use 2D single-slice acquisitions; however newer techniques allow for motion-compensated reconstructions in three dimensions and beyond. To further address confounding factors and improve measurement accuracy, T 1 maps can be acquired jointly with other quantitative parameters such as T 2 , T 2 ∗ , fat fraction, and more. These multiparametric acquisitions allow for constrained reconstruction approaches that isolate contributions to T 1 from other motion and relaxation mechanisms. In this review, we examine the state of the literature in motion-corrected and motion-resolved T 1 mapping, with potential future directions for further technical development and clinical translation.
Collapse
Affiliation(s)
- Calder D. Sheagren
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Tianle Cao
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States
- Department of Bioengineering, University of California, Los Angeles, CA, United States
| | - Jaykumar H. Patel
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Zihao Chen
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States
- Department of Bioengineering, University of California, Los Angeles, CA, United States
| | - Hsu-Lei Lee
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States
| | - Nan Wang
- Department of Radiology, Stanford University, Stanford, CA, United States
| | - Anthony G. Christodoulou
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States
- Department of Bioengineering, University of California, Los Angeles, CA, United States
| | - Graham A. Wright
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| |
Collapse
|
11
|
Fotaki A, Velasco C, Prieto C, Botnar RM. Quantitative MRI in cardiometabolic disease: From conventional cardiac and liver tissue mapping techniques to multi-parametric approaches. Front Cardiovasc Med 2023; 9:991383. [PMID: 36756640 PMCID: PMC9899858 DOI: 10.3389/fcvm.2022.991383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 12/29/2022] [Indexed: 01/24/2023] Open
Abstract
Cardiometabolic disease refers to the spectrum of chronic conditions that include diabetes, hypertension, atheromatosis, non-alcoholic fatty liver disease, and their long-term impact on cardiovascular health. Histological studies have confirmed several modifications at the tissue level in cardiometabolic disease. Recently, quantitative MR methods have enabled non-invasive myocardial and liver tissue characterization. MR relaxation mapping techniques such as T1, T1ρ, T2 and T2* provide a pixel-by-pixel representation of the corresponding tissue specific relaxation times, which have been shown to correlate with fibrosis, altered tissue perfusion, oedema and iron levels. Proton density fat fraction mapping approaches allow measurement of lipid tissue in the organ of interest. Several studies have demonstrated their utility as early diagnostic biomarkers and their potential to bear prognostic implications. Conventionally, the quantification of these parameters by MRI relies on the acquisition of sequential scans, encoding and mapping only one parameter per scan. However, this methodology is time inefficient and suffers from the confounding effects of the relaxation parameters in each single map, limiting wider clinical and research applications. To address these limitations, several novel approaches have been proposed that encode multiple tissue parameters simultaneously, providing co-registered multiparametric information of the tissues of interest. This review aims to describe the multi-faceted myocardial and hepatic tissue alterations in cardiometabolic disease and to motivate the application of relaxometry and proton-density cardiac and liver tissue mapping techniques. Current approaches in myocardial and liver tissue characterization as well as latest technical developments in multiparametric quantitative MRI are included. Limitations and challenges of these novel approaches, and recommendations to facilitate clinical validation are also discussed.
Collapse
Affiliation(s)
- Anastasia Fotaki
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom,*Correspondence: Anastasia Fotaki,
| | - Carlos Velasco
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom,School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile,Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile,Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile
| | - René M. Botnar
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom,School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile,Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile,Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile
| |
Collapse
|
12
|
Weberling LD, Lossnitzer D, Frey N, André F. Coronary Computed Tomography vs. Cardiac Magnetic Resonance Imaging in the Evaluation of Coronary Artery Disease. Diagnostics (Basel) 2022; 13:diagnostics13010125. [PMID: 36611417 PMCID: PMC9818886 DOI: 10.3390/diagnostics13010125] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 12/23/2022] [Accepted: 12/28/2022] [Indexed: 01/04/2023] Open
Abstract
Coronary artery disease (CAD) represents a widespread burden to both individual and public health, steadily rising across the globe. The current guidelines recommend non-invasive anatomical or functional testing prior to invasive procedures. Both coronary computed tomography angiography (cCTA) and stress cardiac magnetic resonance imaging (CMR) are appropriate imaging modalities, which are increasingly used in these patients. Both exhibit excellent safety profiles and high diagnostic accuracy. In the last decade, cCTA image quality has improved, radiation exposure has decreased and functional information such as CT-derived fractional flow reserve or perfusion can complement anatomic evaluation. CMR has become more robust and faster, and advances have been made in functional assessment and tissue characterization allowing for earlier and better risk stratification. This review compares both imaging modalities regarding their strengths and weaknesses in the assessment of CAD and aims to give physicians rationales to select the most appropriate modality for individual patients.
Collapse
Affiliation(s)
- Lukas D. Weberling
- Department of Cardiology, Angiology and Pneumology, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Heidelberg/Mannheim, 69120 Heidelberg, Germany
- Correspondence: ; Tel.: +49-6221-8676
| | - Dirk Lossnitzer
- Department of Cardiology, Angiology and Pneumology, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany
| | - Norbert Frey
- Department of Cardiology, Angiology and Pneumology, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Heidelberg/Mannheim, 69120 Heidelberg, Germany
| | - Florian André
- Department of Cardiology, Angiology and Pneumology, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Heidelberg/Mannheim, 69120 Heidelberg, Germany
| |
Collapse
|
13
|
Hufnagel S, Metzner S, Kerkering KM, Aigner CS, Kofler A, Schulz-Menger J, Schaeffter T, Kolbitsch C. 3D model-based super-resolution motion-corrected cardiac T1 mapping. Phys Med Biol 2022; 67. [PMID: 36265478 DOI: 10.1088/1361-6560/ac9c40] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 10/20/2022] [Indexed: 12/13/2022]
Abstract
Objective. To provide 3D high-resolution cardiac T1 maps using model-based super-resolution reconstruction (SRR).Approach. Due to signal-to-noise ratio limitations and the motion of the heart during imaging, often 2D T1 maps with only low through-plane resolution (i.e. slice thickness of 6-8 mm) can be obtained. Here, a model-based SRR approach is presented, which combines multiple stacks of 2D acquisitions with 6-8 mm slice thickness and generates 3D high-resolution T1 maps with a slice thickness of 1.5-2 mm. Every stack was acquired in a different breath hold (BH) and any misalignment between BH was corrected retrospectively. The novelty of the proposed approach is the BH correction and the application of model-based SRR on cardiac T1 Mapping. The proposed approach was evaluated in numerical simulations and phantom experiments and demonstrated in four healthy subjects.Main results. Alignment of BH states was essential for SRR even in healthy volunteers. In simulations, respiratory motion could be estimated with an RMS error of 0.18 ± 0.28 mm. SRR improved the visualization of small structures. High accuracy and precision (average standard deviation of 69.62 ms) of the T1 values was ensured by SRR while the detectability of small structures increased by 40%.Significance. The proposed SRR approach provided T1 maps with high in-plane and high through-plane resolution (1.3 × 1.3 × 1.5-2 mm3). The approach led to improvements in the visualization of small structures and precise T1 values.
Collapse
Affiliation(s)
- Simone Hufnagel
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Selma Metzner
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | | | | | - Andreas Kofler
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Jeanette Schulz-Menger
- Charité Medical Faculty University Medicine, Berlin, Germany.,Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center (ECRC), Charité Humboldt University Berlin, DZHK partner site Berlin, Berlin, Germany.,Department of Cardiology and Nephrology, HELIOS Klinikum Berlin Buch, Berlin, Germany
| | - Tobias Schaeffter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.,School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Department of Biomedical Engineering, Technical University of Berlin, Berlin, Germany
| | - Christoph Kolbitsch
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| |
Collapse
|
14
|
Eyre K, Lindsay K, Razzaq S, Chetrit M, Friedrich M. Simultaneous multi-parametric acquisition and reconstruction techniques in cardiac magnetic resonance imaging: Basic concepts and status of clinical development. Front Cardiovasc Med 2022; 9:953823. [PMID: 36277755 PMCID: PMC9582154 DOI: 10.3389/fcvm.2022.953823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 09/22/2022] [Indexed: 11/13/2022] Open
Abstract
Simultaneous multi-parametric acquisition and reconstruction techniques (SMART) are gaining attention for their potential to overcome some of cardiovascular magnetic resonance imaging's (CMR) clinical limitations. The major advantages of SMART lie within their ability to simultaneously capture multiple "features" such as cardiac motion, respiratory motion, T1/T2 relaxation. This review aims to summarize the overarching theory of SMART, describing key concepts that many of these techniques share to produce co-registered, high quality CMR images in less time and with less requirements for specialized personnel. Further, this review provides an overview of the recent developments in the field of SMART by describing how they work, the parameters they can acquire, their status of clinical testing and validation, and by providing examples for how their use can improve the current state of clinical CMR workflows. Many of the SMART are in early phases of development and testing, thus larger scale, controlled trials are needed to evaluate their use in clinical setting and with different cardiac pathologies.
Collapse
Affiliation(s)
- Katerina Eyre
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada,*Correspondence: Katerina Eyre,
| | - Katherine Lindsay
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Saad Razzaq
- Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Michael Chetrit
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Matthias Friedrich
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| |
Collapse
|
15
|
Cao T, Wang N, Kwan AC, Lee HL, Mao X, Xie Y, Nguyen KL, Colbert CM, Han F, Han P, Han H, Christodoulou AG, Li D. Free-breathing, non-ECG, simultaneous myocardial T 1 , T 2 , T 2 *, and fat-fraction mapping with motion-resolved cardiovascular MR multitasking. Magn Reson Med 2022; 88:1748-1763. [PMID: 35713184 PMCID: PMC9339519 DOI: 10.1002/mrm.29351] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 04/18/2022] [Accepted: 05/17/2022] [Indexed: 01/11/2023]
Abstract
PURPOSE To develop a free-breathing, non-electrocardiogram technique for simultaneous myocardial T1 , T2 , T2 *, and fat-fraction (FF) mapping in a single scan. METHODS The MR Multitasking framework is adapted to quantify T1 , T2 , T2 *, and FF simultaneously. A variable TR scheme is developed to preserve temporal resolution and imaging efficiency. The underlying high-dimensional image is modeled as a low-rank tensor, which allows accelerated acquisition and efficient reconstruction. The accuracy and/or repeatability of the technique were evaluated on static and motion phantoms, 12 healthy volunteers, and 3 patients by comparing to the reference techniques. RESULTS In static and motion phantoms, T1 /T2 /T2 */FF measurements showed substantial consistency (R > 0.98) and excellent agreement (intraclass correlation coefficient > 0.93) with reference measurements. In human subjects, the proposed technique yielded repeatable T1 , T2 , T2 *, and FF measurements that agreed with those from references. CONCLUSIONS The proposed free-breathing, non-electrocardiogram, motion-resolved Multitasking technique allows simultaneous quantification of myocardial T1 , T2 , T2 *, and FF in a single 2.5-min scan.
Collapse
Affiliation(s)
- Tianle Cao
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| | - Nan Wang
- Radiology Department, Stanford University, Stanford, California, USA
| | - Alan C. Kwan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Imaging and Cardiology, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Hsu-Lei Lee
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Xianglun Mao
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Yibin Xie
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Kim-Lien Nguyen
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
- David Geffen School of Medicine and VA Greater Los Angeles Healthcare System, Los Angeles, California, USA
| | - Caroline M. Colbert
- David Geffen School of Medicine and VA Greater Los Angeles Healthcare System, Los Angeles, California, USA
- Physics and Biology in Medicine, University of California, Los Angeles, Los Angeles, California, USA
| | - Fei Han
- Siemens Medical Solutions USA, Inc., Los Angeles, California, USA
| | - Pei Han
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| | - Hui Han
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| | - Anthony G. Christodoulou
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| | - Debiao Li
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA
| |
Collapse
|
16
|
Velasco C, Fletcher TJ, Botnar RM, Prieto C. Artificial intelligence in cardiac magnetic resonance fingerprinting. Front Cardiovasc Med 2022; 9:1009131. [PMID: 36204566 PMCID: PMC9530662 DOI: 10.3389/fcvm.2022.1009131] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 08/30/2022] [Indexed: 11/13/2022] Open
Abstract
Magnetic resonance fingerprinting (MRF) is a fast MRI-based technique that allows for multiparametric quantitative characterization of the tissues of interest in a single acquisition. In particular, it has gained attention in the field of cardiac imaging due to its ability to provide simultaneous and co-registered myocardial T1 and T2 mapping in a single breath-held cardiac MRF scan, in addition to other parameters. Initial results in small healthy subject groups and clinical studies have demonstrated the feasibility and potential of MRF imaging. Ongoing research is being conducted to improve the accuracy, efficiency, and robustness of cardiac MRF. However, these improvements usually increase the complexity of image reconstruction and dictionary generation and introduce the need for sequence optimization. Each of these steps increase the computational demand and processing time of MRF. The latest advances in artificial intelligence (AI), including progress in deep learning and the development of neural networks for MRI, now present an opportunity to efficiently address these issues. Artificial intelligence can be used to optimize candidate sequences and reduce the memory demand and computational time required for reconstruction and post-processing. Recently, proposed machine learning-based approaches have been shown to reduce dictionary generation and reconstruction times by several orders of magnitude. Such applications of AI should help to remove these bottlenecks and speed up cardiac MRF, improving its practical utility and allowing for its potential inclusion in clinical routine. This review aims to summarize the latest developments in artificial intelligence applied to cardiac MRF. Particularly, we focus on the application of machine learning at different steps of the MRF process, such as sequence optimization, dictionary generation and image reconstruction.
Collapse
Affiliation(s)
- Carlos Velasco
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- *Correspondence: Carlos Velasco
| | - Thomas J. Fletcher
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - René M. Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile
| |
Collapse
|
17
|
Jarkman C, Carlhäll CJ, Henningsson M. Clinical evaluation of the Multimapping technique for simultaneous myocardial T1 and T2 mapping. Front Cardiovasc Med 2022; 9:960403. [PMID: 36148079 PMCID: PMC9485633 DOI: 10.3389/fcvm.2022.960403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 08/05/2022] [Indexed: 11/16/2022] Open
Abstract
The Multimapping technique was recently proposed for simultaneous myocardial T1 and T2 mapping. In this study, we evaluate its correlation with clinical reference mapping techniques in patients with a range of cardiovascular diseases (CVDs) and compare image quality and inter- and intra-observer repeatability. Multimapping consists of an ECG-triggered, 2D single-shot bSSFP readout with inversion recovery and T2 preparation modules, acquired across 10 cardiac cycles. The sequence was implemented at 1.5T and compared to clinical reference mapping techniques, modified Look-Locker inversion recovery (MOLLI) and T2 prepared bSSFP with four echo times (T2bSSFP), and compared in 47 patients with CVD (of which 44 were analyzed). In diseased myocardial segments (defined as the presence of late gadolinium enhancement), there was a high correlation between Multimapping and MOLLI for native myocardium T1 (r2 = 0.73), ECV (r2 = 0.91), and blood T1 (r2 = 0.88), and Multimapping and T2bSSFP for native myocardial T2 (r2 = 0.80). In healthy myocardial segments, a bias for native T1 (Multimapping = 1,116 ± 21 ms, MOLLI = 1,002 ± 21, P < 0.001), post-contrast T1 (Multimapping = 479 ± 31 ms, MOLLI = 426 ± 27 ms, 0.001), ECV (Multimapping = 21.5 ± 1.9%, MOLLI = 23.7 ± 2.3%, P = 0.001), and native T2 (Multimapping = 48.0 ± 3.0 ms, T2bSSFP = 53.9 ± 3.5 ms, P < 0.001) was observed. The image quality for Multimapping was scored as higher for all mapping techniques (native T1, post-contrast T1, ECV, and T2bSSFP) compared to the clinical reference techniques. The inter- and intra-observer agreements were excellent (intraclass correlation coefficient, ICC > 0.9) for most measurements, except for inter-observer repeatability of Multimapping native T1 (ICC = 0.87), post-contrast T1 (ICC = 0.73), and T2bSSFP native T2 (ICC = 0.88). Multimapping shows high correlations with clinical reference mapping techniques for T1, T2, and ECV in a diverse cohort of patients with different cardiovascular diseases. Multimapping enables simultaneous T1 and T2 mapping and can be performed in a short breath-hold, with image quality superior to that of the clinical reference techniques.
Collapse
Affiliation(s)
- Charlotta Jarkman
- Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring Sciences (HMV), Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Markus Henningsson
- Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring Sciences (HMV), Linköping University, Linköping, Sweden
- *Correspondence: Markus Henningsson
| |
Collapse
|