1
|
Sajal SSA, Islam DZ, Khandker SS, Solórzano-Ortiz E, Fardoun M, Ahmed MF, Jamiruddin MR, Azmuda N, Mehta M, Kumar S, Haque M, Adnan N. Strategies to Overcome Erroneous Outcomes in Reverse Transcription-Polymerase Chain Reaction (RT-PCR) Testing: Insights From the COVID-19 Pandemic. Cureus 2024; 16:e72954. [PMID: 39498425 PMCID: PMC11532724 DOI: 10.7759/cureus.72954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2024] [Accepted: 11/03/2024] [Indexed: 11/07/2024] Open
Abstract
The reverse transcription-polymerase chain reaction (RT-PCR) test to detect SARS-CoV-2, the virus causing COVID-19, has been regarded as the diagnostic gold standard. However, the excessive sensitivity of RT-PCR may cause false-positive outcomes from contamination. Again, its technical complexity increases the chances of false-negatives due to pre-analytical and analytical errors. This narrative review explores the elements contributing to inaccurate results during the COVID-19 pandemic and offers strategies to minimize these errors. False-positive results may occur due to specimen contamination, non-specific primer binding, residual viral RNA, and false-negatives, which may arise from improper sampling, timing, labeling, storage, low viral loads, mutations, and faulty test kits. Proposed mitigation strategies to enhance the accuracy of RT-PCR testing include comprehensive staff training in specimen collection, optimizing the timing of tests, analyzing multiple gene targets, incorporating clinical findings, workflow automation, and implementing stringent contamination control measures. Identifying and rectifying sources of error in RT-PCR diagnosis through quality control and standardized protocols is imperative for ensuring quality patient care and effective epidemic control.
Collapse
Affiliation(s)
- Sm Shafiul Alam Sajal
- Department of Biochemistry and Molecular Biology, Jahangirnagar University, Dhaka, BGD
| | | | - Shahad Saif Khandker
- Department of Microbiology, Gonoshasthaya Samaj Vittik Medical College, Dhaka, BGD
| | - Elizabeth Solórzano-Ortiz
- Department of Chemical, Biological, Biomedical and Biophysical Research, Mariano Gálvez University, Guatemala City, GTM
| | - Manal Fardoun
- Department of Pharmacology and Toxicology, Faculty of Medicine, American University of Beirut, Beirut, LBN
| | - Md Firoz Ahmed
- Department of Microbiology, Jahangirnagar University, Dhaka, BGD
| | - Mohd Raeed Jamiruddin
- Department of Pharmacy, Bangladesh Rural Advancement Committee (BRAC) University, Dhaka, BGD
| | - Nafisa Azmuda
- Department of Microbiology, Jahangirnagar University, Dhaka, BGD
| | - Miral Mehta
- Department of Pedodontics and Preventive Dentistry, Karnavati School of Dentistry, Karnavati University, Gandhinagar, IND
| | - Santosh Kumar
- Department of Periodontology and Implantology, Karnavati School of Dentistry, Karnavati University, Gandhinagar, IND
| | - Mainul Haque
- Department of Pharmacology and Therapeutics, National Defence University of Malaysia, Kuala Lumpur, MYS
| | - Nihad Adnan
- Department of Microbiology, Jahangirnagar University, Dhaka, BGD
| |
Collapse
|
2
|
Hu J, Hu J, Jin L, Hu D, Nicholls PK, Wang T, Ren Y, Hu D, Ma B. Use of high-resolution fluorescence in situ hybridization for fast and robust detection of SARS-CoV-2 RNAs. Sci Rep 2024; 14:20906. [PMID: 39245656 PMCID: PMC11381525 DOI: 10.1038/s41598-024-70980-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Accepted: 08/22/2024] [Indexed: 09/10/2024] Open
Abstract
Early, rapid, and accurate diagnostic tests play critical roles not only in the identification/management of individuals infected by SARS-CoV-2, but also in fast and effective public health surveillance, containment, and response. Our aim has been to develop a fast and robust fluorescence in situ hybridization (FISH) detection method for detecting SARS-CoV-2 RNAs by using an HEK 293 T cell culture model. At various times after being transfected with SARS-CoV-2 E and N plasmids, HEK 293 T cells were fixed and then hybridized with ATTO-labeled short DNA probes (about 20 nt). At 4 h, 12 h, and 24 h after transfection, SARS-CoV-2 E and N mRNAs were clearly revealed as solid granular staining inside HEK 293 T cells at all time points. Hybridization time was also reduced to 1 h for faster detection, and the test was completed within 3 h with excellent results. In addition, we have successfully detected 3 mRNAs (E mRNA, N mRNA, and ORF1a (-) RNA) simultaneously inside the buccal cells of COVID-19 patients. Our high-resolution RNA FISH might significantly increase the accuracy and efficiency of SARS-CoV-2 detection, while significantly reducing test time. The method can be conducted on smears containing cells (e.g., from nasopharyngeal, oropharyngeal, or buccal swabs) or smears without cells (e.g., from sputum, saliva, or drinking water/wastewater) for detecting various types of RNA viruses and even DNA viruses at different timepoints of infection.
Collapse
Affiliation(s)
- Jiapei Hu
- Tangshan Clinical Medical College, Hebei Medical University, Tangshan, Hebei, China
- Graduate School, Hebei Medical University, Shijiazhuang, Hebei, China
| | - Jiayi Hu
- Tangshan Clinical Medical College, Hebei Medical University, Tangshan, Hebei, China
- Graduate School, Hebei Medical University, Shijiazhuang, Hebei, China
| | - Li Jin
- Tangshan Clinical Medical College, Hebei Medical University, Tangshan, Hebei, China
- Graduate School, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
| | - Dakang Hu
- Department of Laboratory Medicine, Taizhou Municipal Hospital, Taizhou, Zhejiang, China
| | - Philip K Nicholls
- School of Medical, Molecular and Forensic Sciences, Murdoch University, 90 South Street, Murdoch, WA, 6149, Australia
| | - Tao Wang
- Telethon Kids Institute, Perth Children's Hospital, Nedlands, WA, Australia
- Medical School, University of Western Australia, Nedlands, WA, Australia
| | - Yonglin Ren
- School of Agricultural Science, Murdoch University, Murdoch, WA, Australia
| | - Dailun Hu
- Department of Pathogenic Biology, Hebei Medical University, 361 Zhongshan East Road, Shijiazhuang, 050017, Hebei, China.
| | - Bin Ma
- School of Medical, Molecular and Forensic Sciences, Murdoch University, 90 South Street, Murdoch, WA, 6149, Australia.
- Centre for Healthy Aging, Health Futures Institute, Murdoch University, Murdoch, WA, Australia.
| |
Collapse
|
3
|
Tripodi D, Dominici R, Sacco D, Pozzobon C, Spiti S, Falbo R, Brambilla P, Mascagni P, Leoni V. Antibody Response against SARS-CoV-2 after mRNA Vaccine in a Cohort of Hospital Healthy Workers Followed for 17 Months. Vaccines (Basel) 2024; 12:506. [PMID: 38793757 PMCID: PMC11125999 DOI: 10.3390/vaccines12050506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/01/2024] [Accepted: 05/02/2024] [Indexed: 05/26/2024] Open
Abstract
The assessment of antibody response to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is of critical importance to verify the protective efficacy of available vaccines. Hospital healthcare workers play an essential role in the care and treatment of patients and were particularly at risk of contracting the SARS-CoV-2 infection during the pandemic. The vaccination protocol introduced in our hospital protected the workers and contributed to the containment of the infection' s spread and transmission, although a reduction in vaccine efficacy against symptomatic and breakthrough infections in vaccinated individuals was observed over time. Here, we present the results of a longitudinal and prospective analysis of the anti-SARS-CoV-2 antibodies at multiple time points over a 17-month period to determine how circulating antibody levels change over time following natural infection and vaccination for SARS-CoV-2 before (T0-T4) and after the spread of the omicron variant (T5-T6), analyzing the antibody response of 232 healthy workers at the Pio XI hospital in Desio. A General Estimating Equation model indicated a significant association of the antibody response with time intervals and hospital area, independent of age and sex. Specifically, a similar pattern of antibody response was observed between the surgery and administrative departments, and a different pattern with higher peaks of average antibody response was observed in the emergency and medical departments. Furthermore, using a logistic model, we found no differences in contracting SARS-CoV-2 after the third dose based on the hospital department. Finally, analysis of antibody distribution following the spread of the omicron variant, subdividing the cohort of positive individuals into centiles, highlighted a cut-off of 550 BAU/mL and showed that subjects with antibodies below this are more susceptible to infection than those with a concentration above the established cut-off value.
Collapse
Affiliation(s)
- Domenico Tripodi
- Laboratory of Clinical Pathology and Toxicology, Hospital Pio XI of Desio, ASST-Brianza, 20832 Desio, Italy; (D.T.); (R.D.)
- Department of Medicine and Surgery, University of Milano-Bicocca, 20900 Monza, Italy
| | - Roberto Dominici
- Laboratory of Clinical Pathology and Toxicology, Hospital Pio XI of Desio, ASST-Brianza, 20832 Desio, Italy; (D.T.); (R.D.)
| | - Davide Sacco
- Department of Brain and Behavioural Sciences, Università degli Studi di Pavia, 27100 Pavia, Italy;
- Laboratory of Medical Genetics, Centro Diagnostico Italiano, 20100 Milan, Italy
| | - Claudia Pozzobon
- Laboratory of Clinical Pathology and Toxicology, Hospital Pio XI of Desio, ASST-Brianza, 20832 Desio, Italy; (D.T.); (R.D.)
| | - Simona Spiti
- Laboratory of Clinical Pathology and Toxicology, Hospital Pio XI of Desio, ASST-Brianza, 20832 Desio, Italy; (D.T.); (R.D.)
| | - Rosanna Falbo
- Laboratory of Clinical Pathology and Toxicology, Hospital Pio XI of Desio, ASST-Brianza, 20832 Desio, Italy; (D.T.); (R.D.)
| | - Paolo Brambilla
- Laboratory of Clinical Pathology and Toxicology, Hospital Pio XI of Desio, ASST-Brianza, 20832 Desio, Italy; (D.T.); (R.D.)
- Department of Medicine and Surgery, University of Milano-Bicocca, 20900 Monza, Italy
| | - Paolo Mascagni
- Clinical Unit of Occupational Health, Desio Hospital, ASST Brianza, 20832 Desio, Italy
| | - Valerio Leoni
- Laboratory of Clinical Pathology and Toxicology, Hospital Pio XI of Desio, ASST-Brianza, 20832 Desio, Italy; (D.T.); (R.D.)
- Department of Medicine and Surgery, University of Milano-Bicocca, 20900 Monza, Italy
| |
Collapse
|
4
|
Wang Z, Wei P. Shifting the paradigm in RNA virus detection: integrating nucleic acid testing and immunoassays through single-molecule digital ELISA. Front Immunol 2024; 14:1331981. [PMID: 38235132 PMCID: PMC10791976 DOI: 10.3389/fimmu.2023.1331981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 12/12/2023] [Indexed: 01/19/2024] Open
Abstract
In this review article, we explore the characteristics of RNA viruses and their potential threats to humanity. We also provide a brief overview of the primary contemporary techniques used for the early detection of such viruses. After thoroughly analyzing the strengths and limitations of these methods, we highlight the importance of integrating nucleic acid testing with immunological assays in RNA virus detection. Although notable methodological differences between nucleic acid testing and immune assays pose challenges, the emerging single-molecule immunoassay-digital ELISA may be applied to technically integrate these techniques. We emphasize that the greatest value of digital ELISA is its extensive compatibility, which creates numerous opportunities for real-time, large-scale testing of RNA viruses. Furthermore, we describe the possible developmental trends of digital ELISA in various aspects, such as reaction carriers, identification elements, signal amplification, and data reading, thus revealing the remarkable potential of single-molecule digital ELISA in future RNA virus detection.
Collapse
Affiliation(s)
| | - Pei Wei
- Department of Immunology, Zunyi Medical University, Zhuhai, China
| |
Collapse
|
5
|
Pantazopoulos I, Chalkias A, Miziou A, Spanos M, Gerovasileiou E, Rouka E, Gourgoulianis K. A Hypertonic Seawater Nasal Irrigation Solution Containing Algal and Herbal Natural Ingredients Reduces Viral Load and SARS-CoV-2 Detection Time in the Nasal Cavity. J Pers Med 2023; 13:1093. [PMID: 37511706 PMCID: PMC10381905 DOI: 10.3390/jpm13071093] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/26/2023] [Accepted: 06/30/2023] [Indexed: 07/30/2023] Open
Abstract
Nasal irrigation is thought to decrease the viral load present in the nasal cavity. Our aim was to assess the effect of a hypertonic seawater solution [with algal and herbal natural ingredients (Sinomarin®)] on the viral load of nasopharynx in patients hospitalized with severe COVID-19 pneumonia. We conducted a prospective, randomized, controlled trial from June 2022 to December 2022. We allocated 56 patients with COVID-19 pneumonia into two groups (28 in each group)-the hypertonic seawater group [nasal irrigations with a hypertonic seawater solution (Sinomarin®) every 4 h for 16 h per day, for two consecutive days] and the control group (no nasal irrigations). A second nasopharyngeal swab was collected 48 h after the baseline nasopharyngeal swab (8 h after the last wash in the hypertonic seawater group) to estimate the SARS-CoV-2 viral load as determined by cycle threshold (Ct) values. In the hypertonic seawater group, the mean Ct values significantly increased two days after the initial measurement [ΔCt 48-0 h = 3.86 ± 3.03 cycles, p < 0.001 (95%CI: 2.69 to 5.04)]. No significant differences in the Ct values were observed in the control group [ΔCt 48-0 h = -0.14 ± 4.29, p = 0.866 (95%CI: -1.80 to -1.52)]. At follow-up, 17 patients from the hypertonic seawater group had negative test results compared to only 9 patients from the control group (p = 0.03). Nasal irrigations with a hypertonic seawater solution containing algal and herbal natural ingredients significantly decreased nasopharyngeal viral load and the detection time of SARS-CoV-2 in the nasal cavity.
Collapse
Affiliation(s)
- Ioannis Pantazopoulos
- Department of Emergency Medicine, Faculty of Medicine, University of Thessaly, 41500 Larissa, Greece
- Department of Respiratory Medicine, Faculty of Medicine, University of Thessaly, 41500 Larissa, Greece
| | - Athanasios Chalkias
- Department of Anaesthesiology, Faculty of Medicine, University of Thessaly, 41500 Larissa, Greece
- Institute for Translational Medicine and Therapeutics, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104, USA
- Outcomes Research Consortium, Cleveland, OH 44195, USA
| | - Angeliki Miziou
- Department of Respiratory Medicine, Faculty of Medicine, University of Thessaly, 41500 Larissa, Greece
| | - Michalis Spanos
- Department of Emergency Medicine, Faculty of Medicine, University of Thessaly, 41500 Larissa, Greece
| | - Efrosyni Gerovasileiou
- Department of Respiratory Medicine, Faculty of Medicine, University of Thessaly, 41500 Larissa, Greece
| | - Erasmia Rouka
- Faculty of Nursing, University of Thessaly, 45550 Larissa, Greece
| | | |
Collapse
|
6
|
Yang W, Li D, Chen L, You S, Chen L. Hybridization-driven fluorometric platform based on metal-organic frameworks for the identification of the highly homologous viruses. Microchem J 2023; 187:108403. [PMID: 36643618 PMCID: PMC9824912 DOI: 10.1016/j.microc.2023.108403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 01/05/2023] [Accepted: 01/06/2023] [Indexed: 01/09/2023]
Abstract
A novel fluorometric strategy for the simultaneous identification of SARS-CoV-2 and SARS-CoV was successfully established based on a hybridization-induced signal on-off-on mechanism. Here, one part of the probe (P1) of SARS-CoV-2 (P = P1/P2) is partially related to SARS-CoV, while the other part (P2) is completely irrelevant to SARS-CoV. They as smart gatekeepers were anchored on NH2-MIL-88(Fe) (MOF@P1/P2) to turn off its catalytic performance. Only the specific SARS-CoV-2 genetic target can strongly restore the peroxidase-like activity of MOF@P1/P2. In the presence of o-phenylenediamine, SARS-CoV-2 can be efficiently detected with high sensitivity, accuracy, and reliability. This strategy demonstrated excellent analytical characteristics with a linear range (10-9 M ∼ 10-6 M) under the limit of detection of 0.11 nM not only in buffer but also in 10 % serum, which partly shows its practicability. Most importantly, with the help of the auxiliary test of MOF@P1 and MOF@P2, SARS-CoV-2 and SARS-CoV can be efficiently quantified and distinguished. This novel strategy has provided a breakthrough in the development of such identification. In the whole process, only a simple one-step experiment was involved. This circumvents the trouble of pretreatment experiments in traditional methods, including complex enzymatic mixtures, specialized experimental equipment, many primers optimization as well as reverse transcriptase. Additionally, this novel strategy is rapid, low-cost, and easy-to-use tools.
Collapse
|
7
|
Development and Evaluation of a Novel One-Step RT-qPCR Targeting the Vero Gene for the Identification of False-Positive Results Caused by Inactivated Virus Vaccine Contamination. Vaccines (Basel) 2023; 11:vaccines11020372. [PMID: 36851250 PMCID: PMC9959469 DOI: 10.3390/vaccines11020372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 02/01/2023] [Accepted: 02/04/2023] [Indexed: 02/10/2023] Open
Abstract
To identify false-positive SARS-CoV-2 test results caused by novel coronavirus inactivated vaccine contamination, a novel RT-qPCR targeting the ORF1ab and N genes of SARS-CoV-2 and Vero gene was developed. The amplification efficiency, precision, and lower limit of detection (LLOD) of the RT-qPCR assay were determined. A total of 346 clinical samples and 132 environmental samples were assessed, and the diagnostic performance was evaluated. The results showed that the amplification efficiency of the ORF1ab, N, and Vero genes was 95%, 97%, and 93%, respectively. The coefficients of variation of Ct values at a concentration of 3 × 104 copies/mL were lower than 5%. The LLOD for the ORF1ab, N, and Vero genes reached 8.0, 3.3, and 8.2 copies/reaction, respectively. For the 346 clinical samples, our RT-qPCR assay identified SARS-CoV-2-positive and SARS-CoV-2-negative samples with a sensitivity of 100.00% and a specificity of 99.30% and novel coronavirus inactivated vaccine-contaminated samples with a sensitivity of 100% and a specificity of 100%. For the environmental samples, our RT-qPCR assay identified novel coronavirus inactivated vaccine-contaminated samples with a sensitivity of 88.06% and a specificity of 95.38%. In conclusion, the RT-qPCR assay we established can be used to diagnose COVID-19 and, to a certain extent, false-positive results due to vaccine contamination.
Collapse
|
8
|
Wang Y, Li X, Wang Y, Tu Z, Xu J, Pan J, Zhou Q. Comparison of the performance of two real-time fluorescent quantitative PCR kits for the detection of SARS-CoV-2 nucleic acid: a study based on large real clinical samples. Virol J 2022; 19:191. [PMID: 36401275 PMCID: PMC9675236 DOI: 10.1186/s12985-022-01922-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 11/10/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The global pandemic of coronavirus disease 2019 (COVID-19) has led to the development of multiple detection kits by national manufacturers for severe acute respiratory syndrome coronavirus 2 viral nucleic acid testing. The purpose of this study is to evaluate the performance of different kits (i.e., Maccura kit and Sansure kit) in real clinical work using clinical samples, which will help with the optimization of the test kits. METHOD During the past three months (March-May 2022), 1399 pharyngeal swabs from suspected COVID-19 patients have been initially screened using the Maccura kit in Jilin, China, and the test results were verified using the Sansure kit. The cycle threshold (Ct) values generated by the two kits were compared at different viral load levels. Correlation and consistency of the Ct values were investigated using Spearman correlation, Deming regression, and Bland-Altman plots. The cut-off Ct values of the Maccura kit were recalculated by referencing the result of the Sansure kit as a standard. Furthermore, another 163 pharyngeal swabs from suspected COVID-19 patients were collected to verify the new cut-off values. RESULTS As a result of the Maccura kit testing, 1192 positive cases and 207 suspected COVID-19 cases were verified. After re-examination by the Sansure kit, 1118 positive cases were confirmed. The difference between the Ct values provided by the two kits was statistically significant, except for the N gene at high viral load. The Ct values obtained from the two kits presented a linear positive correlation. The Maccura kit used new cut-off Ct values of 35.00 (ORF1ab gene) and 35.07 (N gene). Based on that, the validation pass rate for the new cut-off Ct values was 91.41%. CONCLUSION Since the Maccura kit is found to have false positives in actual clinical work, recalculation of the cut-off values can reduce this occurrence. In order to improve the accuracy of the testing, laboratories should use two kits for COVID-19 testing, and the adjusting and optimizing of the kits for their situation are needed.
Collapse
Affiliation(s)
- Yiting Wang
- Department of Laboratory Medicine, First Hospital of Jilin University, 1 Xinmin Street, Changchun, 130021 China
| | - Xuewen Li
- Department of Laboratory Medicine, First Hospital of Jilin University, 1 Xinmin Street, Changchun, 130021 China
| | - Yifei Wang
- Department of Laboratory Medicine, First Hospital of Jilin University, 1 Xinmin Street, Changchun, 130021 China
| | - Zheyu Tu
- Department of Laboratory Medicine, First Hospital of Jilin University, 1 Xinmin Street, Changchun, 130021 China
| | - Jiancheng Xu
- Department of Laboratory Medicine, First Hospital of Jilin University, 1 Xinmin Street, Changchun, 130021 China
| | - Junqi Pan
- University of Melbourne, Grattan Street, Parkville, VIC 3010 Australia
| | - Qi Zhou
- Department of Pediatrics, First Hospital of Jilin University, 1 Xinmin Street, Changchun, 130021 China
| |
Collapse
|