1
|
Cao HL, Wei W, Meng YJ, Deng RH, Li XJ, Deng W, Liu YS, Tang Z, Du XD, Greenshaw AJ, Li ML, Li T, Guo WJ. Interactions between overweight/obesity and alcohol dependence impact human brain white matter microstructure: evidence from DTI. Eur Arch Psychiatry Clin Neurosci 2025; 275:439-449. [PMID: 38403735 DOI: 10.1007/s00406-024-01760-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 01/13/2024] [Indexed: 02/27/2024]
Abstract
There is inconsistent evidence for an association of obesity with white matter microstructural alterations. Such inconsistent findings may be related to the cumulative effects of obesity and alcohol dependence. This study aimed to investigate the possible interactions between alcohol dependence and overweight/obesity on white matter microstructure in the human brain. A total of 60 inpatients with alcohol dependence during early abstinence (44 normal weight and 16 overweight/obese) and 65 controls (42 normal weight and 23 overweight/obese) were included. The diffusion tensor imaging (DTI) measures [fractional anisotropy (FA) and radial diffusivity (RD)] of the white matter microstructure were compared between groups. We observed significant interactive effects between alcohol dependence and overweight/obesity on DTI measures in several tracts. The DTI measures were not significantly different between the overweight/obese and normal-weight groups (although widespread trends of increased FA and decreased RD were observed) among controls. However, among the alcohol-dependent patients, the overweight/obese group had widespread reductions in FA and widespread increases in RD, most of which significantly differed from the normal-weight group; among those with overweight/obesity, the alcohol-dependent group had widespread reductions in FA and widespread increases in RD, most of which were significantly different from the control group. This study found significant interactive effects between overweight/obesity and alcohol dependence on white matter microstructure, indicating that these two controllable factors may synergistically impact white matter microstructure and disrupt structural connectivity in the human brain.
Collapse
Affiliation(s)
- Hai-Ling Cao
- Mental Health Center, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China
| | - Wei Wei
- Department of Neurobiology, Affiliated Mental Health Center and Hangzhou Seventh People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310063, China
| | - Ya-Jing Meng
- Mental Health Center, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China
| | - Ren-Hao Deng
- Mental Health Center, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China
| | - Xiao-Jing Li
- Department of Neurobiology, Affiliated Mental Health Center and Hangzhou Seventh People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310063, China
| | - Wei Deng
- Department of Neurobiology, Affiliated Mental Health Center and Hangzhou Seventh People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310063, China
| | - Yan-Song Liu
- Department of Clinical Psychology, Suzhou Psychiatric Hospital, The Affiliated Guangji Hospital of Soochow University, Suzhou, Jiangsu, China
| | - Zhen Tang
- Department of Clinical Psychology, Suzhou Psychiatric Hospital, The Affiliated Guangji Hospital of Soochow University, Suzhou, Jiangsu, China
| | - Xiang-Dong Du
- Department of Clinical Psychology, Suzhou Psychiatric Hospital, The Affiliated Guangji Hospital of Soochow University, Suzhou, Jiangsu, China
| | | | - Ming-Li Li
- Mental Health Center, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China
| | - Tao Li
- Department of Neurobiology, Affiliated Mental Health Center and Hangzhou Seventh People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310063, China
| | - Wan-Jun Guo
- Mental Health Center, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
- Department of Neurobiology, Affiliated Mental Health Center and Hangzhou Seventh People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310063, China.
- Liangzhu Laboratory, MOE Frontier Science Center for Brain Science and Brain-Machine Integration, State Key Laboratory of Brain-Machine Intelligence, Zhejiang University, 1369 West Wenyi Road, Hangzhou, 311121, China.
| |
Collapse
|
2
|
Zennifer A, Chellappan DR, Chinnaswamy P, Subramanian A, Sundaramurthi D, Sethuraman S. Efficacy of 3D printed anatomically equivalent thermoplastic polyurethane guide conduits in promoting the regeneration of critical-sized peripheral nerve defects. Biofabrication 2024; 16:045015. [PMID: 38968935 DOI: 10.1088/1758-5090/ad5fbe] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 07/05/2024] [Indexed: 07/07/2024]
Abstract
Three-dimensional (3D) printing is an emerging tool for creating patient-specific tissue constructs analogous to the native tissue microarchitecture. In this study, anatomically equivalent 3D nerve conduits were developed using thermoplastic polyurethane (TPU) by combining reverse engineering and material extrusion (i.e. fused deposition modeling) technique. Printing parameters were optimized to fabricate nerve-equivalent TPU constructs. The TPU constructs printed with different infill densities supported the adhesion, proliferation, and gene expression of neuronal cells. Subcutaneous implantation of the TPU constructs for three months in rats showed neovascularization with negligible local tissue inflammatory reactions and was classified as a non-irritant biomaterial as per ISO 10993-6. To performin vivoefficacy studies, nerve conduits equivalent to rat's sciatic nerve were fabricated and bridged in a 10 mm sciatic nerve transection model. After four months of implantation, the sensorimotor function and histological assessments revealed that the 3D printed TPU conduits promoted the regeneration in critical-sized peripheral nerve defects equivalent to autografts. This study proved that TPU-based 3D printed nerve guidance conduits can be created to replicate the complicated features of natural nerves that can promote the regeneration of peripheral nerve defects and also show the potential to be extended to several other tissues for regenerative medicine applications.
Collapse
Affiliation(s)
- Allen Zennifer
- Tissue Engineering & Additive Manufacturing (TEAM) Lab, Centre for Nanotechnology & Advanced Biomaterials, ABCDE Innovation Centre, School of Chemical & Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu 613 401, India
| | - David Raj Chellappan
- Central Animal Facility, School of Chemical & Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu 613 401, India
| | - Prabu Chinnaswamy
- Department of Veterinary Pathology, Veterinary College and Research Institute, Orathanadu, Tamil Nadu 614 625, India
| | - Anuradha Subramanian
- Tissue Engineering & Additive Manufacturing (TEAM) Lab, Centre for Nanotechnology & Advanced Biomaterials, ABCDE Innovation Centre, School of Chemical & Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu 613 401, India
| | - Dhakshinamoorthy Sundaramurthi
- Tissue Engineering & Additive Manufacturing (TEAM) Lab, Centre for Nanotechnology & Advanced Biomaterials, ABCDE Innovation Centre, School of Chemical & Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu 613 401, India
| | - Swaminathan Sethuraman
- Tissue Engineering & Additive Manufacturing (TEAM) Lab, Centre for Nanotechnology & Advanced Biomaterials, ABCDE Innovation Centre, School of Chemical & Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu 613 401, India
| |
Collapse
|
3
|
Cobbs A, Alas G, Yadav R, Mayeux J, Eckmann MS, Provenzano DA, English AW, Washington A, Wang R. Water-circulating probes significantly modify lesion length and axon damage in cooled radiofrequency ablations when compared with similar-sized standard radiofrequency probes in rats. Reg Anesth Pain Med 2024; 49:448-454. [PMID: 37748801 PMCID: PMC11187385 DOI: 10.1136/rapm-2023-104554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 08/14/2023] [Indexed: 09/27/2023]
Abstract
INTRODUCTION Preclinical research demonstrated water-cooled radiofrequency (CRF) ablations have a significant impact on structural and functional changes compared to standard radiofrequency (SRF) ablations. Clinical procedures utilizing RF to treat chronic pain conditions also show sustained functional outcomes. We hypothesize that the design of the RF probes plays an important role in interventional procedure success, but it remains unclear which specific design features. METHODS RF ablations were performed in male Lewis rats (n=51) using multiple-sized probes for CRF (17 Ga/2 mm and 17Ga/4 mm) and SRF (22Ga/5 mm, 18Ga/10 mm and 16Ga/10 mm) to evaluate generator energy output, lesion length, axon damage by histology and nerve function analysis via electromyography. To exclude probe design variables beyond size and remain objective, we tested cooled probes with and without water circulation, which resulted in the CRF probe performing like an SRF probe. RESULTS Consistent with our previous findings in smaller probes, CRF large probes delivered more energy (p<0.01) and generated multiple zones of thermal damage in sciatic nerves. When the water-circulating feature was turned off, however, energy output (p<0.001) and lesion length (p<0.05) was significantly reduced. CRF probes with the water circulation also featured significantly more axonal disruption, than larger sized SRF probes (p<0.0001). CONCLUSIONS Overall, this data confirms that CRF's water-circulating technology has a greater impact on energy deposition, lesion length and axon damage compared with SRF ablations. Moreover, results suggest that the structural differences between RF modalities cannot be solely attributed to probe size, and it may shed light on its differences in clinical outcomes.
Collapse
Affiliation(s)
- Alyssa Cobbs
- Research and Development, Avanos Medical Inc, Alpharetta, Georgia, USA
| | - Guillermo Alas
- Research and Development, Avanos Medical Inc, Alpharetta, Georgia, USA
| | - Ruchi Yadav
- Research and Development, Avanos Medical Inc, Alpharetta, Georgia, USA
| | - Jacques Mayeux
- Research and Development, Avanos Medical Inc, Alpharetta, Georgia, USA
| | - Maxim S Eckmann
- Anesthesiology, Univ Texas Hlth Sci Ctr San Antonio, San Antonio, Texas, USA
| | | | | | | | - Ruoya Wang
- Research and Development, Avanos Medical Inc, Alpharetta, Georgia, USA
| |
Collapse
|
4
|
Tovbis D, Lee E, Koh RGL, Jeong R, Agur A, Yoo PB. Enhancing the selective electrical activation of human vagal nerve fibers: a comparative computational modeling study with validation in a rat sciatic model. J Neural Eng 2023; 20:066012. [PMID: 37963401 DOI: 10.1088/1741-2552/ad0c60] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 11/14/2023] [Indexed: 11/16/2023]
Abstract
Objective.Vagus nerve stimulation (VNS) is an emerging treatment option for a myriad of medical disorders, where the method of delivering electrical pulses can vary depending on the clinical indication. In this study, we investigated the relative effectiveness of electrically activating the cervical vagus nerve among three different approaches: nerve cuff electrode stimulation (NCES), transcutaneous electrical nerve stimulation (TENS), and enhanced TENS (eTENS). The objectives were to characterize factors that influenced nerve activation and to compare the nerve recruitment properties as a function of nerve fiber diameter.Methods.The Finite Element Model, based on data from the Visible Human Project, was implemented in COMSOL. The three simulation types were compared under a range of vertical and horizontal displacements relative to the location of the vagus nerve. Monopolar anodic stimulation was examined, along with latency and activation of different fiber sizes. Nerve activation was determined via the activating function and McIntyre-Richardson-Grill models, and activation thresholds were validated in anin-vivorodent model.Results.While NCES produced the lowest activation thresholds, eTENS generally performed superior to TENS under the range of conditions and fiber diameters, producing activation thresholds up to three times lower than TENS. eTENS also preserved its enhancement when surface electrodes were displaced away from the nerve. Anodic stimulation revealed an inhibitory region that removed eTENS benefits. eTENS also outperformed TENS by up to four times when targeting smaller diameter nerve fibers, scaling similar to a cuff electrode. In latency and activation of smaller diameter nerve fibers, eTENS results resembled those of NCES more than a TENS electrode. Activation threshold ratios were consistent inin-vivovalidation.Significance.Our findings expand upon previously identified mechanisms for eTENS and further demonstrate how eTENS emulates a nerve cuff electrode to achieve lower activation thresholds. This work further characterizes considerations required for VNS under the three stimulation methods.
Collapse
Affiliation(s)
- Daniel Tovbis
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
| | - Eugene Lee
- Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada
| | - Ryan G L Koh
- KITE Research Institute, Toronto Rehabilitation Institute, University Health Network, Toronto, Canada
| | - Rania Jeong
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
| | - Anne Agur
- Division of Anatomy, Department of Surgery, University of Toronto, Toronto, Canada
- Rehabilitation Sciences Institute, University of Toronto, Toronto, Canada
| | - Paul B Yoo
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
- Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada
| |
Collapse
|
5
|
Szaro P, Suresh R, Molokwu B, Sibala DR, Mendiratta D, Chu A, McGrath A. Magnetic resonance imaging for diagnosis of suspected neurogenic thoracic outlet syndrome-a systematic scoping review. Front Physiol 2023; 14:1198165. [PMID: 37920804 PMCID: PMC10619157 DOI: 10.3389/fphys.2023.1198165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 10/06/2023] [Indexed: 11/04/2023] Open
Abstract
Background: Neurogenic Thoracic Outlet Syndrome (nTOS) is a rare pathology caused by dynamic conditions or compression of neurovascular structures in the thoracic outlet region. nTOS can be difficult to diagnose due to nonspecific symptoms and magnetic resonance imaging (MRI) techniques are increasingly used to aid the diagnosis and surgical planning. This scoping systematic review explores how MRI is used for diagnosing nTOS and summarizes details of published MRI protocols. Methods: A systematic screening of PubMed, Cochrane, Web of Science, and CINAHL databases using PRISMA-IPD guidelines was conducted in September 2022 to include full-text English papers on MRI and nTOS. Inclusion criteria involved studies describing MRI protocols for the diagnosis of TOS, with a focus on the imaging sequences and protocols. Results: 6289 papers were screened to include 28 papers containing details of MRI protocols. The details of MRI protocols in the analyzed articles were incomplete in all studies. Most authors used 1.5T systems and included T1 and T2-weighted sequences. Most studies applied fat suppression, mainly with STIR. Positioning of the arm differed between studies, including neutral, hyperabducted and abducted and externally rotated positions. Conclusion: Our review highlights a prevalent lack of detailed MRI protocol documentation for brachial plexus. Authors primarily rely on conventional 1.5T systems, employing standard T1 and T2-weighted sequences. The adoption of novel MRI sequences is notably lacking, and fat suppression techniques predominantly adhere to older methods as STIR. There is a clear imperative for authors to provide more comprehensive reporting of the MRI protocols utilized in their studies, ultimately enhancing comparability and clinical applicability. Establishing clear protocol reporting guidelines is crucial to allow for comparison between studies.
Collapse
Affiliation(s)
- Pawel Szaro
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Musculoskeletal Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Rohan Suresh
- Department of Orthopaedics, Rutgers New Jersey Medical School, Newark, NJ, United States
| | - Brian Molokwu
- Department of Orthopaedics, Rutgers New Jersey Medical School, Newark, NJ, United States
| | - Dhiraj Raju Sibala
- Department of Orthopaedics, Rutgers New Jersey Medical School, Newark, NJ, United States
| | - Dhruv Mendiratta
- Department of Orthopaedics, Rutgers New Jersey Medical School, Newark, NJ, United States
| | - Alice Chu
- Department of Orthopaedics, Rutgers New Jersey Medical School, Newark, NJ, United States
| | - Aleksandra McGrath
- Department of Clinical Sciences, Umeå University, Umeå, Sweden
- Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden
| |
Collapse
|