1
|
Cook J, Umar M, Khalili F, Taebi A. Body Acoustics for the Non-Invasive Diagnosis of Medical Conditions. Bioengineering (Basel) 2022; 9:bioengineering9040149. [PMID: 35447708 PMCID: PMC9032059 DOI: 10.3390/bioengineering9040149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 03/27/2022] [Accepted: 03/30/2022] [Indexed: 11/16/2022] Open
Abstract
In the past few decades, many non-invasive monitoring methods have been developed based on body acoustics to investigate a wide range of medical conditions, including cardiovascular diseases, respiratory problems, nervous system disorders, and gastrointestinal tract diseases. Recent advances in sensing technologies and computational resources have given a further boost to the interest in the development of acoustic-based diagnostic solutions. In these methods, the acoustic signals are usually recorded by acoustic sensors, such as microphones and accelerometers, and are analyzed using various signal processing, machine learning, and computational methods. This paper reviews the advances in these areas to shed light on the state-of-the-art, evaluate the major challenges, and discuss future directions. This review suggests that rigorous data analysis and physiological understandings can eventually convert these acoustic-based research investigations into novel health monitoring and point-of-care solutions.
Collapse
Affiliation(s)
- Jadyn Cook
- Department of Agricultural and Biological Engineering, Mississippi State University, 130 Creelman Street, Starkville, MS 39762, USA;
| | - Muneebah Umar
- Department of Biological Sciences, Mississippi State University, 295 Lee Blvd, Starkville, MS 39762, USA;
| | - Fardin Khalili
- Department of Mechanical Engineering, Embry-Riddle Aeronautical University, 1 Aerospace Blvd, Daytona Beach, FL 32114, USA;
| | - Amirtahà Taebi
- Department of Agricultural and Biological Engineering, Mississippi State University, 130 Creelman Street, Starkville, MS 39762, USA;
- Correspondence: ; Tel.: +1-(662)-325-5987
| |
Collapse
|
2
|
Kelly NS, McCree D, Fresiello L, Brynedal Ignell N, Cookson AN, Najar A, Perkins IL, Fraser KH. Video-based valve motion combined with computational fluid dynamics gives stable and accurate simulations of blood flow in the Realheart total artificial heart. Artif Organs 2021; 46:57-70. [PMID: 34460941 DOI: 10.1111/aor.14056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 07/29/2021] [Accepted: 08/25/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Patients with end-stage, biventricular heart failure, and for whom heart transplantation is not an option, may be given a Total Artificial Heart (TAH). The Realheart® is a novel TAH which pumps blood by mimicking the native heart with translation of an atrioventricular plane. The aim of this work was to create a strategy for using Computational Fluid Dynamics (CFD) to simulate haemodynamics in the Realheart®, including motion of the atrioventricular plane and valves. METHODS The accuracies of four different computational methods for simulating fluid-structure interaction of the prosthetic valves were assessed by comparison of chamber pressures and flow rates with experimental measurements. The four strategies were: prescribed motion of valves opening and closing at the atrioventricular plane extrema; simulation of fluid-structure interaction of both valves; prescribed motion of the mitral valve with simulation of fluid-structure interaction of the aortic valve; motion of both valves prescribed from video analysis of experiments. RESULTS The most accurate strategy (error in ventricular pressure of 6%, error in flow rate of 5%) used video-prescribed motion. With the Realheart operating at 80 bpm, the power consumption was 1.03 W, maximum shear stress was 15 Pa, and washout of the ventricle chamber after 4 cycles was 87%. CONCLUSIONS This study, the first CFD analysis of this novel TAH, demonstrates that good agreement between computational and experimental data can be achieved. This method will therefore enable future optimisation of the geometry and motion of the Realheart®.
Collapse
Affiliation(s)
| | - Danny McCree
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Libera Fresiello
- Department of Cardiovascular Sciences, Katholieke Universiteit (KU) Leuven, Leuven, Belgium
| | | | - Andrew N Cookson
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Azad Najar
- Scandinavian Real Heart AB, Västerås, Sweden
| | | | | |
Collapse
|
3
|
Khalili F, Gamage PT, Taebi A, Johnson ME, Roberts RB, Mitchel J. Spectral Decomposition and Sound Source Localization of Highly Disturbed Flow through a Severe Arterial Stenosis. Bioengineering (Basel) 2021; 8:bioengineering8030034. [PMID: 33806695 PMCID: PMC8000318 DOI: 10.3390/bioengineering8030034] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 02/07/2021] [Accepted: 02/22/2021] [Indexed: 01/01/2023] Open
Abstract
For the early detection of atherosclerosis, it is imperative to explore the capabilities of new, effective noninvasive diagnosis techniques to significantly reduce the associated treatment costs and mortality rates. In this study, a multifaceted comprehensive approach involving advanced computational fluid dynamics combined with signal processing techniques was exploited to investigate the highly turbulent fluctuating flow through arterial stenosis. The focus was on localizing high-energy mechano-acoustic source potential to transmit to the epidermal surface. The flow analysis results showed the existence of turbulent pressure fluctuations inside the stenosis and in the post-stenotic region. After analyzing the turbulent kinetic energy and pressure fluctuations on the flow centerline and the vessel wall, the point of maximum excitation in the flow was observed around two diameters downstream of the stenosis within the fluctuating zone. It was also found that the concentration of pressure fluctuation closer to the wall was higher inside the stenosis compared to the post-stenotic region. Additionally, the visualization of the most energetic proper orthogonal decomposition (POD) mode and spectral decomposition of the flow indicated that the break frequencies ranged from 80 to 220 Hz and were correlated to the eddies generated within these regions.
Collapse
Affiliation(s)
- Fardin Khalili
- Department of Mechanical Engineering, Embry-Riddle Aeronautical University, 1 Aerospace Boulevard, Daytona Beach, FL 32114, USA
- Correspondence:
| | - Peshala T. Gamage
- Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, 2930 Science Cir., Melbourne, FL 32901, USA;
| | - Amirtahà Taebi
- Department of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616, USA;
| | - Mark E. Johnson
- Telecraft Engineering Inc., 1254 Mount Carmel Church Lane, Canton, GA 30114, USA; (M.E.J.); (R.B.R.)
| | - Randal B. Roberts
- Telecraft Engineering Inc., 1254 Mount Carmel Church Lane, Canton, GA 30114, USA; (M.E.J.); (R.B.R.)
| | - John Mitchel
- Infrasonix Inc., 1665 Lakes Parkway, Suite 102, Lawrenceville, GA 30043, USA;
| |
Collapse
|
4
|
Proper Orthogonal Decomposition Analysis of the Flow Downstream of a Dysfunctional Bileaflet Mechanical Aortic Valve. Cardiovasc Eng Technol 2021; 12:286-299. [PMID: 33469847 DOI: 10.1007/s13239-021-00519-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 01/02/2021] [Indexed: 12/14/2022]
Abstract
PURPOSE Aortic valve replacement remains the only viable solution for symptomatic patients with severe aortic valve stenosis. Despite their improved design and long history of successful operation, bileaflet mechanical heart valves are still associated with post-operative complications leading to valve dysfunction. Thus, the flow dynamics can be highly disturbed downstream of the dysfunctional valve. METHODS In this in vitro study, the flow dynamics downstream of healthy and dysfunctional bileaflet mechanical heart valves have been investigated using particle image velocimetry measurements. Proper orthogonal decomposition of the velocity field has been performed in order to explore the coherent flow features in the ascending aorta in the presence of a dysfunctional bileaflet mechanical heart valve. RESULTS The ability of proper orthogonal decomposition derived metrics to differentiate between heathy and dysfunctional cases is reported. Moreover, reduced-order modeling using proper orthogonal decomposition is thoroughly investigated not only for the velocity field but also for higher order flow characteristics such as time average wall shear stress, oscillatory shear index and viscous energy dissipation. CONCLUSION Considering these results, proper orthogonal decomposition can provide a rapid binary classifier to evaluate if the bileaflet mechanical valve deviates from its normal operating conditions. Moreover, the study shows that the size of the reduced-order model depends on which flow parameter is required to be reconstructed.
Collapse
|
5
|
The effect of fundamental curves on geometric orifice and coaptation areas of polymeric heart valves. J Mech Behav Biomed Mater 2020; 112:104039. [DOI: 10.1016/j.jmbbm.2020.104039] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 08/04/2020] [Accepted: 08/12/2020] [Indexed: 12/29/2022]
|
6
|
Introduction to the Special Issue on Advances in Biological Tissue Biomechanics. Bioengineering (Basel) 2020; 7:bioengineering7030095. [PMID: 32824476 PMCID: PMC7552630 DOI: 10.3390/bioengineering7030095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 08/14/2020] [Indexed: 11/20/2022] Open
|
7
|
Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study. Bioengineering (Basel) 2020; 7:bioengineering7030090. [PMID: 32784661 PMCID: PMC7552677 DOI: 10.3390/bioengineering7030090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 07/29/2020] [Accepted: 08/06/2020] [Indexed: 01/09/2023] Open
Abstract
The prosthetic heart valve is vulnerable to dysfunction after surgery, thus a frequent assessment is required. Doppler electrocardiography and its quantitative parameters are commonly used to assess the performance of the prosthetic heart valves and provide detailed information on the interaction between the heart chambers and related prosthetic valves, allowing early detection of complications. However, in the case of the presence of subaortic stenosis, the accuracy of Doppler has not been fully investigated in previous studies and guidelines. Therefore, it is important to evaluate the accuracy of the parameters in such cases to get early detection, and a proper treatment plan for the patient, at the right time. In the current study, a CFD simulation was performed for the blood flow through a Bileaflet Mechanical Heart Valve (BMHV) with concomitant obstruction in the Left Ventricle Outflow Tract (LVOT). The current study explores the impact of the presence of the subaortic on flow patterns. It also investigates the accuracy of (BMHV) evaluation using Doppler parameters, as proposed in the American Society of Echocardiography (ASE) guidelines.
Collapse
|
8
|
Madhurapantula RS, Krell G, Morfin B, Roy R, Lister K, Orgel JP. Advanced Methodology and Preliminary Measurements of Molecular and Mechanical Properties of Heart Valves under Dynamic Strain. Int J Mol Sci 2020; 21:E763. [PMID: 31991583 PMCID: PMC7037596 DOI: 10.3390/ijms21030763] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 01/15/2020] [Accepted: 01/21/2020] [Indexed: 11/16/2022] Open
Abstract
Mammalian heart valves are soft tissue assemblies with multi-scale material properties. This is because they are constructs comprising both muscle and non-contractile extracellular matrix proteins (such as collagens and proteoglycans) and transition regions where one form of tissue structure becomes another, significantly different form. The leaflets of the mitral and tricuspid valves are connected to chordae tendinae which, in turn, bind through papillary muscles to the cardiac wall of the ventricle. The transition regions between these tissue subsets are complex and diffuse. Their material composition and mechanical properties have not been previously described with both micro and nanoscopic data recorded simultaneously, as reported here. Annotating the mechanical characteristics of these tissue transitions will be of great value in developing novel implants, improving the state of the surgical simulators and advancing robot-assisted surgery. We present here developments in multi-scale methodology that produce data that can relate mechanical properties to molecular structure using scanning X-ray diffraction. We correlate these data to corresponding tissue level (macro and microscopic) stress and strain, with particular emphasis on the transition regions and present analyses to indicate points of possible failure in these tissues.
Collapse
Affiliation(s)
- Rama S. Madhurapantula
- Department of Biology, Illinois Institute of Technology, Chicago, IL 60616, USA;
- Pritzker Institute of Biomedical Science and Engineering, Illinois Institute of Technology, Chicago, IL 60616, USA;
| | - Gabriel Krell
- Pritzker Institute of Biomedical Science and Engineering, Illinois Institute of Technology, Chicago, IL 60616, USA;
| | - Berenice Morfin
- Department of Biology, Illinois Institute of Technology, Chicago, IL 60616, USA;
| | - Rajarshi Roy
- Corvid Technologies, Mooresville, NC 28117, USA; (R.R.); (K.L.)
| | - Kevin Lister
- Corvid Technologies, Mooresville, NC 28117, USA; (R.R.); (K.L.)
| | - Joseph P.R.O. Orgel
- Department of Biology, Illinois Institute of Technology, Chicago, IL 60616, USA;
- Pritzker Institute of Biomedical Science and Engineering, Illinois Institute of Technology, Chicago, IL 60616, USA;
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616, USA
| |
Collapse
|
9
|
Mirvakili N, Di Labbio G, Saleh W, Kadem L. Flow characteristics in a model of a left ventricle in the presence of a dysfunctional mitral mechanical heart valve. J Vis (Tokyo) 2019. [DOI: 10.1007/s12650-019-00611-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
10
|
Benim AC, Frank T, Assmann A, Lichtenberg A, Akhyari P. Computational investigation of hemodynamics in hardshell venous reservoirs: A comparative study. Artif Organs 2019; 44:411-418. [PMID: 31660617 DOI: 10.1111/aor.13593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 10/05/2019] [Accepted: 10/07/2019] [Indexed: 11/28/2022]
Abstract
Extracorporeal circulation using heart-lung-machines is associated with a profound activation of corpuscular and plasmatic components of circulating blood, which can also lead to deleterious events such as systemic inflammatory response and hemolysis. Individual components used to install the extracorporeal circulation have an impact on the level of activation, most predominantly membrane oxygenators and hardshell venous reservoirs as used in extracorporeal systems. The blood flows in two different hardshell reservoirs are computationally investigated. A special emphasis is placed on the prediction of an onset of transition and turbulence generation. Reynolds-averaged numerical simulations (RANS) based on a transitional turbulence model, as well as large eddy simulations (LES) are applied to achieve an accurate prediction. In the LES analysis, the non-Newtonian behavior of the blood is considered via the Carreau model. Blood damage potential is quantified applying the Modified Index of Hemolysis (MIH) based on the predicted flow fields. The results indicate that the flows in both reservoirs remain predominantly laminar. For one of the reservoirs, considerable turbulence generation is observed near the exit site, caused by the specific design for the connection with the drainage tube. This difference causes the MIH of this reservoir to be nearly twice as large as compared to the alternative design. However, a substantial improvement of these performance criteria can be expected by a local geometry modification.
Collapse
Affiliation(s)
- Ali Cemal Benim
- Department of Mechanical and Process Engineering, Duesseldorf University of Applied Sciences-Center of Flow Simulation (CFS), Duesseldorf, Germany
| | - Thiemo Frank
- Department of Cardiovascular Surgery, Heinrich Heine University, Duesseldorf, Germany
| | - Alexander Assmann
- Department of Cardiovascular Surgery, Heinrich Heine University, Duesseldorf, Germany
| | - Artur Lichtenberg
- Department of Cardiovascular Surgery, Heinrich Heine University, Duesseldorf, Germany
| | - Payam Akhyari
- Department of Cardiovascular Surgery, Heinrich Heine University, Duesseldorf, Germany
| |
Collapse
|
11
|
Gulbulak U, Ertas A. Finite Element Driven Design Domain Identification of a Beating Left Ventricular Simulator. Bioengineering (Basel) 2019; 6:bioengineering6030083. [PMID: 31540196 PMCID: PMC6784146 DOI: 10.3390/bioengineering6030083] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 08/30/2019] [Accepted: 09/10/2019] [Indexed: 11/24/2022] Open
Abstract
Almost ten percent of the American population have heart diseases. Since the number of available heart donors is not promising, left ventricular assist devices are implemented as bridge therapies. Development of the assist devices benefits from both in-vivo animal and in-vitro mock circulation studies. Representation of the heart is a crucial part of the mock circulation setups. Recently, a beating left ventricular simulator with latex rubber and helically oriented McKibben actuators has been proposed. The simulator was able to mimic heart wall motion, however, flow rate was reported to be limited to 2 liters per minute. This study offers a finite element driven design domain identification to identify the combination of wall thickness, number of actuators, and the orientation angle that results in better deformation. A nonlinear finite element model of the simulator was developed and validated. Design domain was constructed with 150 finite element models, each with varying wall thickness and number of actuators with varying orientation angles. Results showed that the combination of 4 mm wall thickness and 8 actuators with 90 degrees orientation performed best in the design domain.
Collapse
Affiliation(s)
- Utku Gulbulak
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Atila Ertas
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| |
Collapse
|
12
|
Taebi A, Sandler RH, Kakavand B, Mansy HA. Extraction of Peak Velocity Profiles from Doppler Echocardiography Using Image Processing. Bioengineering (Basel) 2019; 6:E64. [PMID: 31357566 PMCID: PMC6784240 DOI: 10.3390/bioengineering6030064] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 07/04/2019] [Accepted: 07/26/2019] [Indexed: 11/26/2022] Open
Abstract
The objective of this study is to extract positive and negative peak velocity profiles from Doppler echocardiographic images. These profiles are currently estimated using tedious manual approaches. Profiles can be used to establish realistic boundary conditions for computational hemodynamic studies and to estimate cardiac time intervals, which are of clinical utility. In the current study, digital image processing algorithms that rely on intensity calculations and two different thresholding methods were proposed and tested. Image intensity histograms were used to guide threshold choices, which were selected such that the resulting velocity profiles appropriately represent Doppler shift envelopes. The resulting peak velocity profiles contained artifacts in the form of sudden velocity changes and possible outliers. To reduce these artifacts, image smoothing using a moving average process was then implemented. Bland-Altman analysis suggested good agreement between the two thresholding methods. Artifacts decreased when image smoothing was performed. Results also suggested that one thresholding method tended to provide the lower limit (i.e., underestimate) of velocities, while the second tended to provide the velocity upper limit (i.e., overestimate). Combining estimates from both methods appeared to provide a smoother peak velocity profile estimate. The proposed automated approach may be useful for objective estimation of peak velocity profiles, which may be helpful for computational hemodynamic studies and may increase the efficiency of current clinical diagnostic tools.
Collapse
Affiliation(s)
- Amirtahà Taebi
- Department of Biomedical Engineering, University of California Davis, One Shields Ave, Davis, CA 95616, USA.
| | - Richard H Sandler
- Biomedical Acoustics Research Laboratory, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL 32816, USA
- College of Medicine, University of Central Florida, 6850 Lake Nona Blvd, Orlando, FL 32827, USA
| | - Bahram Kakavand
- Department of Cardiovascular Services, Nemours Children's Hospital, 13535 Nemours Pky, Orlando, FL 32827, USA
| | - Hansen A Mansy
- Biomedical Acoustics Research Laboratory, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL 32816, USA
| |
Collapse
|
13
|
Darwish A, Di Labbio G, Saleh W, Smadi O, Kadem L. Experimental investigation of the flow downstream of a dysfunctional bileaflet mechanical aortic valve. Artif Organs 2019; 43:E249-E263. [DOI: 10.1111/aor.13483] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 03/26/2019] [Accepted: 04/29/2019] [Indexed: 01/08/2023]
Affiliation(s)
- Ahmed Darwish
- Laboratory of Cardiovascular Fluid Dynamics, Mechanical, Industrial and Aerospace Engineering Concordia University Montreal Quebec Canada
| | - Giuseppe Di Labbio
- Laboratory of Cardiovascular Fluid Dynamics, Mechanical, Industrial and Aerospace Engineering Concordia University Montreal Quebec Canada
| | - Wael Saleh
- Laboratory of Cardiovascular Fluid Dynamics, Mechanical, Industrial and Aerospace Engineering Concordia University Montreal Quebec Canada
| | - Othman Smadi
- Department of Biomedical Engineering Hashemite University Zarqa Jordan
| | - Lyes Kadem
- Laboratory of Cardiovascular Fluid Dynamics, Mechanical, Industrial and Aerospace Engineering Concordia University Montreal Quebec Canada
| |
Collapse
|
14
|
Deng Y, Belfar A, Powell T. Early Prosthetic Valve Malfunction Leading to Cardiogenic Shock and Emergency Redo Mitral Valve Replacement. J Cardiothorac Vasc Anesth 2019; 33:2866-2869. [PMID: 31072708 DOI: 10.1053/j.jvca.2019.03.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 02/12/2019] [Accepted: 03/09/2019] [Indexed: 11/11/2022]
Abstract
Early onset prosthetic valve stenosis is an uncommon complication after valve replacement surgery and is often caused by thrombus formation. Frequently it can be diagnosed by echocardiography and managed with optimizing anticoagulation and/or thrombolysis. We review a unique case of early bi-leaflet mechanical heart valve (BMHV) dysfunction where the patient rapidly progressed to cardiogenic shock requiring emergent re-do mitral valve surgery. Intraoperatively, the valve leaflets were found to be almost completely immobile secondary to thrombus formation directly on the hinges of the valve. This case demonstrates how the leaflet orientation of a BMHV affects transmitral flow and fluid dynamics. Furthermore, we also discuss left atrial vortex formation in the setting of atrial fibrillation, kinetic energy transfer through an anatomically implanted mechanical mitral valve, and their roles in contributing to early prosthetic valve thrombosis despite adequate anticoagulation.
Collapse
Affiliation(s)
- Yi Deng
- Department of Anesthesiology, Baylor College of Medicine, Houston, TX.
| | - Alexandra Belfar
- Department of Anesthesiology, Allegheny Health Network, Pittsburgh, PA
| | - Thomas Powell
- Department of Anesthesiology, Baylor College of Medicine, Houston, TX
| |
Collapse
|
15
|
Use of Computational Fluid Dynamics to Analyze Blood Flow, Hemolysis and Sublethal Damage to Red Blood Cells in a Bileaflet Artificial Heart Valve. FLUIDS 2019. [DOI: 10.3390/fluids4010019] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Artificial heart valves may expose blood to flow conditions that lead to unnaturally high stress and damage to blood cells as well as issues with thrombosis. The purpose of this research was to predict the trauma caused to red blood cells (RBCs), including hemolysis, from the stresses applied to them and their exposure time as determined by analysis of simulation results for blood flow through both a functioning and malfunctioning bileaflet artificial heart valve. The calculations provided the spatial distribution of the Kolmogorov length scales that were used to estimate the spatial and size distributions of the smallest turbulent flow eddies in the flow field. The number and surface area of these eddies in the blood were utilized to predict the amount of hemolysis experienced by RBCs. Results indicated that hemolysis levels are low while suggesting stresses at the leading edge of the leaflet may contribute to subhemolytic damage characterized by shortened circulatory lifetimes and reduced RBC deformability.
Collapse
|