1
|
Latia M, Bena A, Moisa-Luca L, Bunceanu Ș, Stoian D. Shear wave elastography for thyroid nodule evaluation in patients with chronic autoimmune thyroiditis. Endocrine 2025; 88:482-490. [PMID: 39827288 DOI: 10.1007/s12020-025-04159-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2024] [Accepted: 01/07/2025] [Indexed: 01/22/2025]
Abstract
PURPOSE Shear wave elastography (SWE) is a valuable tool in discerning the malignancy risk of thyroid nodules. This study investigates whether 2D-SWE can reliably differentiate malignant thyroid nodules in patients with chronic autoimmune thyroiditis (CAT), despite the challenges posed by fibrosis, which can increase tissue stiffness and complicate diagnosis. METHODS This retrospective observational study evaluated 130 thyroid nodules (91 benign, 39 malignant) in patients with underlying CAT using conventional ultrasound (B-mode) and 2D-SWE with SuperSonic Mach30 equipment (Supersonic Imagine, Aix-en-Provence, France). Pathology reports served as the reference standard. RESULTS Out of the 130 nodules, 30% were malignant, and 70% were benign. 2D-SWE proved to be an excellent distinguisher between benign and malignant nodules. Malignant nodules had significantly higher elasticity indices compared to benign nodules (mean elasticity index: 47.2 kPa vs. 18.1 kPa, p < 0.0001; maximum elasticity index: 75 kPa vs. 26.2 kPa, p < 0.0001). The mean elasticity index was the most reliable elastographic parameter (AUC 0.907, sensitivity 87.2% [95% CI: 77.3-94.0%], specificity 84.6% [95% CI: 75.4-91.5%], and NPV 93.9% for a cut-off value of 30.5 kPa). CONCLUSION Our results confirm that 2D-SWE can accurately diagnose malignant thyroid nodules in cases with CAT (p < 0.0001), supporting its use as a complementary tool to conventional ultrasound.
Collapse
Affiliation(s)
- Monica Latia
- Department of Doctoral Studies, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
- Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania
| | - Andreea Bena
- Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania.
- Center of Molecular Research in Nephrology and Vascular Disease, Faculty of Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania.
- Discipline of Endocrinology, Second Department of Internal Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania.
- Endocrinology Unit, Pius Brinzeu Emergency Clinical Hospital, Timisoara, Romania.
| | - Luciana Moisa-Luca
- Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania
- Center of Molecular Research in Nephrology and Vascular Disease, Faculty of Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
- Discipline of Endocrinology, Second Department of Internal Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
| | - Ștefania Bunceanu
- Department of Doctoral Studies, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
| | - Dana Stoian
- Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania
- Center of Molecular Research in Nephrology and Vascular Disease, Faculty of Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
- Discipline of Endocrinology, Second Department of Internal Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
- Endocrinology Unit, Pius Brinzeu Emergency Clinical Hospital, Timisoara, Romania
| |
Collapse
|
2
|
Borysewicz-Sańczyk H, Bossowski F, Anikiej K, Sawicka B, Michalak J, Dzięcioł J, Bossowski A. Application of shear wave elastography in the management of thyroid nodules in children and adolescents: our experience and a review of the literature. Front Endocrinol (Lausanne) 2024; 15:1486285. [PMID: 39634183 PMCID: PMC11614656 DOI: 10.3389/fendo.2024.1486285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2024] [Accepted: 10/25/2024] [Indexed: 12/07/2024] Open
Abstract
Introduction Shear wave elastography (SWE) is an ultrasound diagnostic method used to measure tissue stiffness. Since the mechanical properties of tissue involved in the pathological process change, SWE might indicate regions of the examined tissue covered by the disease. It is well documented that SWE helps to differentiate benign and malignant nodules in thyroid glands in adults, however, there are few studies on the application of SWE in thyroid diagnosis in children. The purpose of the study was to assess the application of SWE based on Young's modulus expressed in kPa in the management of thyroid nodules in children and adolescents. Methods In total, 116 pediatric patients (81 girls and 35 boys) with 168 thyroid nodules were enrolled in the study and qualified for SWE followed by fine needle aspiration biopsy. Results According to the result of the cytological examination presented in the Bethesda System, nodules were classified as benign (147 nodules classified as category II according to the Bethesda System) or indeterminate or suspicious (21 nodules classified as categories III, IV, and V according to the Bethesda System). Benign cytological diagnoses were nodular goiter, parenchymal goiter, nodular colloid goiter, or lymphocytic inflammation. Among the indeterminate or suspicious nodules, 15 were diagnosed as category III according to the Bethesda System (atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS) in cytology), 1 nodule was diagnosed as category IV according to the Bethesda System (suspicious for follicular neoplasm - oxyphilic cell tumor), and 5 as category V according to the Bethesda System (suspicious for malignancy). There were no significant differences in thyrotropin (TSH) and free thyroxine (fT4) concentrations between the benign and suspicious groups. Patients with benign and indeterminate or suspicious thyroid nodules were of comparable age. Mean SWE in benign nodules was statistically significantly lower than in nodules with indeterminate or suspicious cytology (42.22 ± 16.69 vs. 57.4 ± 24.0 kPa, p=0.0004). Six patients from the indeterminate or suspicious group were revealed to be malignant in the final histopathological examination. Conclusion Our results suggest that SWE is a viable diagnostic method, however, it still seems to need some adjustment for pediatric patients.
Collapse
Affiliation(s)
- Hanna Borysewicz-Sańczyk
- Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Filip Bossowski
- Student Research Group by the Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Katarzyna Anikiej
- Student Research Group by the Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Beata Sawicka
- Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Justyna Michalak
- Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Janusz Dzięcioł
- Department of Human Anatomy, Medical University of Bialystok, Bialystok, Poland
| | - Artur Bossowski
- Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| |
Collapse
|
3
|
Shen G, Zhang X, Qin L, Wu Y, Li H. Application of strain elastography ultrasound to the endometrium of normal women. BMC Med Imaging 2024; 24:153. [PMID: 38902645 PMCID: PMC11188229 DOI: 10.1186/s12880-024-01327-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 06/07/2024] [Indexed: 06/22/2024] Open
Abstract
BACKGROUND While there is a scarcity of studies utilizing strain elastography (SE) for the endometrium, commonly used gynecologic ultrasound instruments are equipped with built-in elastography modalities, primarily SE. With the objective of facilitating comprehensive examinations for gynecologic patients on a single ultrasound instrument, we undertook this study. Therefore, our aim was to study the value of SE ultrasonography in the assessment of endometrial elasticity in normal women. METHODS Three hundred and twenty normal women were recruited at our hospitals from November 2021 to December 2022. Each volunteer underwent a transvaginal two-dimensional (2D) and SE ultrasound during either the endometrial proliferative or secretory phase. The 2D ultrasound indices obtained included endometrial thickness, echo type (type A, B, and C), and blood flow grading (grades 0, 1, 2, and 3). SE indices obtained included endometrial strain values, myometrial strain values, and endometrial strain ratios. Differences in endometrial ultrasound indices between different menstrual cycles and different age groups were compared. RESULTS Comparison of 2D ultrasound parameters revealed that endometrial thickness in the proliferative phase endometrium group was smaller than that in the secretory phase endometrium group, with a statistically significant difference. Additionally, there was a statistically significant difference in endometrial echo types between the two groups, while the disparity in endometrial blood flow grading was not significant. Regarding SE parameters, the median and mean values of endometrial strain ratio in the proliferative phase endometrium group were smaller than those in the secretory phase endometrium group, showing a statistically significant difference. However, there were no significant differences observed between the two groups in endometrial strain and myometrial strain in the fundus. Furthermore, there were no significant differences in any of the endometrial ultrasound indices among the different age groups. CONCLUSIONS SE can reflect changes in endometrial stiffness in different menstrual cycles and is an important tool for assessing endometrial softness.
Collapse
Affiliation(s)
- Guili Shen
- Department of Ultrasound Medicine, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Province Hospital of Chinese Medicine, Nanjing, 210029, China
- Department of Ultrasound Medicine, People's Hospital of Longhua, Shenzhen, 518109, China
| | - Xueling Zhang
- Department of Ultrasound Medicine, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Province Hospital of Chinese Medicine, Nanjing, 210029, China
- Department of Ultrasound Medicine, People's Hospital of Longhua, Shenzhen, 518109, China
| | - Lei Qin
- Department of Ultrasound Medicine, People's Hospital of Longhua, Shenzhen, 518109, China
| | - Yiyun Wu
- Department of Ultrasound Medicine, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Province Hospital of Chinese Medicine, Nanjing, 210029, China
| | - Hongbo Li
- Department of Ultrasound Medicine, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Province Hospital of Chinese Medicine, Nanjing, 210029, China.
- Department of Ultrasound Medicine, People's Hospital of Longhua, Shenzhen, 518109, China.
| |
Collapse
|
4
|
Stoian D, Borlea A, Moisa-Luca L, Paul C. Multiparametric ultrasound-based assessment of overt hyperthyroid diffuse thyroid disease. Front Endocrinol (Lausanne) 2023; 14:1300447. [PMID: 38179308 PMCID: PMC10764279 DOI: 10.3389/fendo.2023.1300447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 11/30/2023] [Indexed: 01/06/2024] Open
Abstract
Introduction Hyperthyroidismis a prevalent condition affecting global populations, with an overall prevalence of 1.2%. Our research aimed to establish a systematic diagnostic approach using multiparametric ultrasound (MPUS) to diagnose hyperthyroid diffuse thyroid disease (DTD). Methods We conducted a retrospective study from June 2021 to June 2023 at a specialized endocrinology center in Timisoara, Romania, enrolling subjects presenting with clinical hyperthyroidism. Using the Mach 30 Aixplorer ultrasound equipment, evaluations were performed initially in B-mode US, followed by Color Doppler and Spectral Doppler measurements, and finally, 2D Shear wave elastography (SWE). Results From the 218 patients analyzed, the diagnosis of DTD with hyperthyroidism was confirmed through biochemical assessment, subgrouping various pathologies such as subacute thyroiditis, Graves' disease, painless thyroiditis, Hashimoto's thyroiditis, iatrogenic, as well as healthy controls. In the first step, B-mode hypoechogenicity had an AUC of 0.951 for DTD detection. In the second step, the peak systolic velocity differentiated Graves' disease with a median of 42.4 cm/s and an AUC of 1. Lastly, the third step consisted of SWE evaluation, revealing a mean elasticity index in the SAT subgroup significantly higher from other subgroups (p<0.001) with an AUC of 1. Conclusion Our study offers a step-by-step evaluation algorithm for DTD diagnosis, with a very good overall diagnostic performance (AUC of 0.946).
Collapse
Affiliation(s)
- Dana Stoian
- Discipline of Endocrinology, Second Department of Internal Medicine, University of Medicine and Pharmacy “Victor Babes”, Timisoara, Romania
- Center for Molecular Research in Nephrology and Vascular Disease, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
| | - Andreea Borlea
- Discipline of Endocrinology, Second Department of Internal Medicine, University of Medicine and Pharmacy “Victor Babes”, Timisoara, Romania
- Center for Molecular Research in Nephrology and Vascular Disease, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
| | - Luciana Moisa-Luca
- Discipline of Endocrinology, Second Department of Internal Medicine, University of Medicine and Pharmacy “Victor Babes”, Timisoara, Romania
| | - Corina Paul
- Department of Pediatrics, University of Medicine and Pharmacy “Victor Babes”, Timisoara, Romania
| |
Collapse
|