1
|
Kim C, Lee K, Kim J, Yang D, Lee H, Moon G, Kim Y, Cho D, Bae KS, Kim G, Kim Y, Lee C. Multi-point sensing organic light-emitting diode display based mobile cardiovascular monitor. Nat Commun 2025; 16:1666. [PMID: 39955318 PMCID: PMC11829945 DOI: 10.1038/s41467-025-56915-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Accepted: 01/29/2025] [Indexed: 02/17/2025] Open
Abstract
Cardiovascular diseases are the major cause of death globally and require ubiquitous monitoring due to their asymptomatic yet modifiable nature. Photoplethysmography is an effective optical sensing technique for non-invasive health monitoring. However, its reliance on the current relatively large and rigid inorganic semiconductor-based light-emitting diodes and silicon photodiodes hampers high-resolution integration thus restricts a sensing from single measurement point. So, it limits detectable biomarkers to monitor cardiovascular diseases in a ubiquitous manner. In order to facilitate, here we report a single smartphone type multi-functional cardiovascular health monitor based on the massive array of organic photodiodes integrated into the most user interactive display device. Therefore, we achieved: 1) multi-point concurrent photoplethysmography and high-resolution dynamic image sensing, and 2) user-interactive sensing within the large display area. These advancements enabled new functions, including high-accuracy screening for cardiovascular diseases, blood pressure monitoring from both fingers, monitoring of finger blood vessels and flow dynamics, and single-device-based biofeedback. Applied machine learning enhanced diagnostic accuracy, with pilot studies showing results comparable to medical-grade devices. As a result, we believe smartphones harnessing the sensor organic light-emitting diode display could evolve into mobile health monitors and digital therapeutics thus revolutionizing diagnostic and treatment.
Collapse
Affiliation(s)
- Chul Kim
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea
| | - Kwangjin Lee
- Deepmedi Research Institute of Technology, Deepmedi Inc, Seoul, Republic of Korea
| | - Jongin Kim
- Deepmedi Research Institute of Technology, Deepmedi Inc, Seoul, Republic of Korea
| | - Dongwook Yang
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea
| | - Hyeonjun Lee
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea
| | - Gyeongub Moon
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea
| | - Yuna Kim
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea
| | - Dongrae Cho
- Deepmedi Research Institute of Technology, Deepmedi Inc, Seoul, Republic of Korea
| | - Kwang Soo Bae
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea
| | - Gunhee Kim
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea
| | - Yongjo Kim
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea
| | - Changhee Lee
- Display Research Center, Samsung Display, Giheung, Gyeonggi, Republic of Korea.
| |
Collapse
|
2
|
Tong Y, Huang Z, Qiu F, Wang T, Wang Y, Qin F, Yin M. An Accurate Non-Contact Photoplethysmography via Active Cancellation of Reflective Interference. IEEE J Biomed Health Inform 2024; 28:7116-7125. [PMID: 39146172 DOI: 10.1109/jbhi.2024.3443988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
Imaging Photoplethysmography (IPPG) is an emerging and efficient optical method for non-contact measurement of pulse waves using an image sensor. While the contactless way brings convenience, the inevitable distance between the sensor and the subject results in massive specular reflection interference on the skin surface, which leads to a low Signal to Interference plus Noise Ratio (SINR) of IPPG. To ease this challenge, this work proposes a novel modulation illumination approach to measure the accurate arterial pulse wave via surface reflection interference isolation from IPPG. Based on the proposed skin reflection model, a specific modulation illumination is designed to separate the surface reflections and obtain the subcutaneous diffuse reflections containing the pulse wave information. Compared with the results under ambient illumination and constant supplemental illumination, the SINR of the proposed method is improved by 4.56 and 3.74 dB, respectively.
Collapse
|
3
|
Pilt K, Reiu A. Effect of transmural pressure on the estimation of arterial stiffness index from the photoplethysmographic waveform. Med Biol Eng Comput 2024; 62:1049-1059. [PMID: 38123887 DOI: 10.1007/s11517-023-02992-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 12/07/2023] [Indexed: 12/23/2023]
Abstract
The aim of this study was to find the effect of transmural pressure on the determination of the photoplethysmographic (PPG) waveform arterial stiffness index (PPGAI). The study was conducted on 51 subjects without diagnosis of cardiovascular disease, aged between 24 and 74 years. The relation between the transmural pressure, which is the difference between the arterial blood pressure and the PPG sensor contact pressure, and the PPGAI was determined. PPG, beat-to-beat blood pressure, and sensor contact pressure signals were recorded from the index, middle, and ring finger. The PPG sensor contact pressure of the index finger was increased from 20 to 120 mmHg. The aortic augmentation index (AIx@75) was estimated with a SphygmoCor device as a reference. High correlation coefficients r = 0.79 and r = 0.83 between PPGAI and AIx@75, and low PPGAI standard deviations were observed at the transmural pressures of 10 and 20 mmHg, respectively. Transmural pressure of 20 mmHg can be considered suitable for the PPG signal registration and PPGAI calculation for the assessment of arterial stiffness. In summary, the contact pressure of the sensor should be selected according to theblood pressure of the subject finger in order to achieve the transmural pressure suitable for the assessment of PPGAI and arterial stiffness.
Collapse
Affiliation(s)
- Kristjan Pilt
- Department of Health Technologies, Tallinn University of Technology, Ehitajate Tee 5, 19086, Tallinn, Estonia.
| | - Andy Reiu
- Department of Health Technologies, Tallinn University of Technology, Ehitajate Tee 5, 19086, Tallinn, Estonia
| |
Collapse
|
4
|
Ferizoli R, Karimpour P, May JM, Kyriacou PA. Arterial stiffness assessment using PPG feature extraction and significance testing in an in vitro cardiovascular system. Sci Rep 2024; 14:2024. [PMID: 38263412 PMCID: PMC10806047 DOI: 10.1038/s41598-024-51395-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 01/04/2024] [Indexed: 01/25/2024] Open
Abstract
Cardiovascular diseases (CVDs) remain the leading cause of global mortality, therefore understanding arterial stiffness is essential to developing innovative technologies to detect, monitor and treat them. The ubiquitous spread of photoplethysmography (PPG), a completely non-invasive blood-volume sensing technology suitable for all ages, highlights immense potential for arterial stiffness assessment in the wider healthcare setting outside specialist clinics, for example during routine visits to a General Practitioner or even at home with the use of mobile and wearable health devices. This study employs a custom-manufactured in vitro cardiovascular system with vessels of varying stiffness to test the hypothesis that PPG signals may be used to detect and assess the level of arterial stiffness under controlled conditions. Analysis of various morphological features demonstrated significant (p < 0.05) correlations with vessel stiffness. Particularly, area related features were closely linked to stiffness in red PPG signals, while for infrared PPG signals the most correlated features were related to pulse-width. This study demonstrates the utility of custom vessels and in vitro investigations to work towards non-invasive cardiovascular assessment using PPG, a valuable tool with applications in clinical healthcare, wearable health devices and beyond.
Collapse
Affiliation(s)
- Redjan Ferizoli
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, UK.
| | - Parmis Karimpour
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, UK
| | - James M May
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, UK
| | - Panicos A Kyriacou
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, UK
| |
Collapse
|
5
|
Charlton PH, Allen J, Bailón R, Baker S, Behar JA, Chen F, Clifford GD, Clifton DA, Davies HJ, Ding C, Ding X, Dunn J, Elgendi M, Ferdoushi M, Franklin D, Gil E, Hassan MF, Hernesniemi J, Hu X, Ji N, Khan Y, Kontaxis S, Korhonen I, Kyriacou PA, Laguna P, Lázaro J, Lee C, Levy J, Li Y, Liu C, Liu J, Lu L, Mandic DP, Marozas V, Mejía-Mejía E, Mukkamala R, Nitzan M, Pereira T, Poon CCY, Ramella-Roman JC, Saarinen H, Shandhi MMH, Shin H, Stansby G, Tamura T, Vehkaoja A, Wang WK, Zhang YT, Zhao N, Zheng D, Zhu T. The 2023 wearable photoplethysmography roadmap. Physiol Meas 2023; 44:111001. [PMID: 37494945 PMCID: PMC10686289 DOI: 10.1088/1361-6579/acead2] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 04/04/2023] [Accepted: 07/26/2023] [Indexed: 07/28/2023]
Abstract
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.
Collapse
Affiliation(s)
- Peter H Charlton
- Department of Public Health and Primary Care, University of Cambridge, Cambridge, CB1 8RN, United Kingdom
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - John Allen
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5RW, United Kingdom
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, United Kingdom
| | - Raquel Bailón
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Stephanie Baker
- College of Science and Engineering, James Cook University, Cairns, 4878 Queensland, Australia
| | - Joachim A Behar
- Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Haifa, 3200003, Israel
| | - Fei Chen
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, 518055 Guandong, People’s Republic of China
| | - Gari D Clifford
- Department of Biomedical Informatics, Emory University, Atlanta, GA 30322, United States of America
- Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America
| | - David A Clifton
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| | - Harry J Davies
- Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2AZ, United Kingdom
| | - Cheng Ding
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America
- Department of Biomedical Engineering, Emory University, Atlanta, GA 30322, United States of America
| | - Xiaorong Ding
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, 611731, People’s Republic of China
| | - Jessilyn Dunn
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
- Department of Biostatistics & Bioinformatics, Duke University, Durham, NC 27708-0187, United States of America
- Duke Clinical Research Institute, Durham, NC 27705-3976, United States of America
| | - Mohamed Elgendi
- Biomedical and Mobile Health Technology Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8008, Switzerland
| | - Munia Ferdoushi
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Daniel Franklin
- Institute of Biomedical Engineering, Translational Biology & Engineering Program, Ted Rogers Centre for Heart Research, University of Toronto, Toronto, M5G 1M1, Canada
| | - Eduardo Gil
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Md Farhad Hassan
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Jussi Hernesniemi
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
- Tampere Heart Hospital, Wellbeing Services County of Pirkanmaa, Tampere, 33520, Finland
| | - Xiao Hu
- Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, 30322, Georgia, United States of America
- Department of Biomedical Informatics, School of Medicine, Emory University, Atlanta, 30322, Georgia, United States of America
- Department of Computer Sciences, College of Arts and Sciences, Emory University, Atlanta, GA 30322, United States of America
| | - Nan Ji
- Hong Kong Center for Cerebrocardiovascular Health Engineering (COCHE), Hong Kong Science and Technology Park, Hong Kong, 999077, People’s Republic of China
| | - Yasser Khan
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Spyridon Kontaxis
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Ilkka Korhonen
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
| | - Panicos A Kyriacou
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - Pablo Laguna
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Jesús Lázaro
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Chungkeun Lee
- Digital Health Devices Division, Medical Device Evaluation Department, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Cheongju, 28159, Republic of Korea
| | - Jeremy Levy
- Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Haifa, 3200003, Israel
- Faculty of Electrical and Computer Engineering, Technion Institute of Technology, Haifa, 3200003, Israel
| | - Yumin Li
- State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, People’s Republic of China
| | - Chengyu Liu
- State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, People’s Republic of China
| | - Jing Liu
- Analog Devices Inc, San Jose, CA 95124, United States of America
| | - Lei Lu
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| | - Danilo P Mandic
- Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2AZ, United Kingdom
| | - Vaidotas Marozas
- Department of Electronics Engineering, Kaunas University of Technology, 44249 Kaunas, Lithuania
- Biomedical Engineering Institute, Kaunas University of Technology, 44249 Kaunas, Lithuania
| | - Elisa Mejía-Mejía
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - Ramakrishna Mukkamala
- Department of Bioengineering and Department of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America
| | - Meir Nitzan
- Department of Physics/Electro-Optic Engineering, Lev Academic Center, 91160 Jerusalem, Israel
| | - Tania Pereira
- INESC TEC—Institute for Systems and Computer Engineering, Technology and Science, Porto, 4200-465, Portugal
- Faculty of Engineering, University of Porto, Porto, 4200-465, Portugal
| | | | - Jessica C Ramella-Roman
- Department of Biomedical Engineering and Herbert Wertheim College of Medicine, Florida International University, Miami, FL 33174, United States of America
| | - Harri Saarinen
- Tampere Heart Hospital, Wellbeing Services County of Pirkanmaa, Tampere, 33520, Finland
| | - Md Mobashir Hasan Shandhi
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
| | - Hangsik Shin
- Department of Digital Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Gerard Stansby
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, United Kingdom
- Northern Vascular Centre, Freeman Hospital, Newcastle upon Tyne, NE7 7DN, United Kingdom
| | - Toshiyo Tamura
- Future Robotics Organization, Waseda University, Tokyo, 1698050, Japan
| | - Antti Vehkaoja
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
- PulseOn Ltd, Espoo, 02150, Finland
| | - Will Ke Wang
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
| | - Yuan-Ting Zhang
- Hong Kong Center for Cerebrocardiovascular Health Engineering (COCHE), Hong Kong Science and Technology Park, Hong Kong, 999077, People’s Republic of China
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, People’s Republic of China
| | - Ni Zhao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong
| | - Dingchang Zheng
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5RW, United Kingdom
| | - Tingting Zhu
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| |
Collapse
|
6
|
Marcinkevics Z, Rubins U, Aglinska A, Logina I, Glazunovs D, Grabovskis A. Contactless photoplethysmography for assessment of small fiber neuropathy. Front Physiol 2023; 14:1180288. [PMID: 37727661 PMCID: PMC10505793 DOI: 10.3389/fphys.2023.1180288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Accepted: 08/02/2023] [Indexed: 09/21/2023] Open
Abstract
Chronic pain is a prevalent condition affecting approximately one-fifth of the global population, with significant impacts on quality of life and work productivity. Small fiber neuropathies are a common cause of chronic pain, and current diagnostic methods rely on subjective self-assessment or invasive skin biopsies, highlighting the need for objective noninvasive assessment methods. The study aims to develop a modular prototype of a contactless photoplethysmography system with three spectral bands (420, 540, and 800 nm) and evaluate its potential for assessing peripheral neuropathy patients via a skin topical heating test and spectral analyses of cutaneous flowmotions. The foot topical skin heating test was conducted on thirty volunteers, including fifteen healthy subjects and fifteen neuropathic patients. Four cutaneous nerve fiber characterizing parameters were evaluated at different wavelengths, including vasomotor response trend, flare area, flare intensity index, and the spectral power of cutaneous flowmotions. The results show that neuropathic patients had significantly lower vasomotor response (50%), flare area (63%), flare intensity index (19%), and neurogenic component (54%) of cutaneous flowmotions compared to the control group, independent of photoplethysmography spectral band. An absolute value of perfusion was 20%-30% higher in the 420 nm band. Imaging photoplethysmography shows potential as a cost-effective alternative for objective and non-invasive assessment of neuropathic patients, but further research is needed to enhance photoplethysmography signal quality and establish diagnostic criteria.
Collapse
Affiliation(s)
- Zbignevs Marcinkevics
- Department of Human and Animal Physiology, Faculty of Biology, University of Latvia, Riga, Latvia
- Biophotonics Laboratory, Institute of Atomic Physics and Spectroscopy, University of Latvia, Riga, Latvia
| | - Uldis Rubins
- Biophotonics Laboratory, Institute of Atomic Physics and Spectroscopy, University of Latvia, Riga, Latvia
| | - Alise Aglinska
- Department of Human and Animal Physiology, Faculty of Biology, University of Latvia, Riga, Latvia
| | - Inara Logina
- Department of Neurology and Neurosurgery, Riga Stradins University, Riga, Latvia
| | - Dmitrijs Glazunovs
- Department of Neurology and Neurosurgery, Riga Stradins University, Riga, Latvia
| | - Andris Grabovskis
- Biophotonics Laboratory, Institute of Atomic Physics and Spectroscopy, University of Latvia, Riga, Latvia
| |
Collapse
|
7
|
Fleischhauer V, Bruhn J, Rasche S, Zaunseder S. Photoplethysmography upon cold stress-impact of measurement site and acquisition mode. Front Physiol 2023; 14:1127624. [PMID: 37324389 PMCID: PMC10267461 DOI: 10.3389/fphys.2023.1127624] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 05/15/2023] [Indexed: 06/17/2023] Open
Abstract
Photoplethysmography (PPG) allows various statements about the physiological state. It supports multiple recording setups, i.e., application to various body sites and different acquisition modes, rendering the technique a versatile tool for various situations. Owing to anatomical, physiological and metrological factors, PPG signals differ with the actual setup. Research on such differences can deepen the understanding of prevailing physiological mechanisms and path the way towards improved or novel methods for PPG analysis. The presented work systematically investigates the impact of the cold pressor test (CPT), i.e., a painful stimulus, on the morphology of PPG signals considering different recording setups. Our investigation compares contact PPG recorded at the finger, contact PPG recorded at the earlobe and imaging PPG (iPPG), i.e., non-contact PPG, recorded at the face. The study bases on own experimental data from 39 healthy volunteers. We derived for each recording setup four common morphological PPG features from three intervals around CPT. For the same intervals, we derived blood pressure and heart rate as reference. To assess differences between the intervals, we used repeated measures ANOVA together with paired t-tests for each feature and we calculated Hedges' g to quantify effect sizes. Our analyses show a distinct impact of CPT. As expected, blood pressure shows a highly significant and persistent increase. Independently of the recording setup, all PPG features show significant changes upon CPT as well. However, there are marked differences between recording setups. Effect sizes generally differ with the finger PPG showing the strongest response. Moreover, one feature (pulse width at half amplitude) shows an inverse behavior in finger PPG and head PPG (earlobe PPG and iPPG). In addition, iPPG features behave partially different from contact PPG features as they tend to return to baseline values while contact PPG features remain altered. Our findings underline the importance of recording setup and physiological as well as metrological differences that relate to the setups. The actual setup must be considered in order to properly interpret features and use PPG. The existence of differences between recording setups and a deepened knowledge on such differences might open up novel diagnostic methods in the future.
Collapse
Affiliation(s)
- Vincent Fleischhauer
- Laboratory for Advanced Measurements and Biomedical Data Analysis, Faculty of Information Technology, FH Dortmund, Dortmund, Germany
| | - Jan Bruhn
- Laboratory for Advanced Measurements and Biomedical Data Analysis, Faculty of Information Technology, FH Dortmund, Dortmund, Germany
| | - Stefan Rasche
- Faculty of Medicine Carl Gustav Carus, TU Dresden, Dresden, Germany
| | - Sebastian Zaunseder
- Laboratory for Advanced Measurements and Biomedical Data Analysis, Faculty of Information Technology, FH Dortmund, Dortmund, Germany
- Professorship for Diagnostic Sensing, Faculty of Applied Computer Science, University Augsburg, Augsburg, Germany
| |
Collapse
|
8
|
Munir Z, Akash M, Jaiprada F, Abu Tarboush B, Ijaz O, Bseiso A, Palleti SK, Amin A. Evaluation of the Effects of Extracorporeal Shockwave Therapy in Patients With Peripheral Arterial Disease: A Meta-Analysis of Randomized Control Trials. Cureus 2023; 15:e34729. [PMID: 36909116 PMCID: PMC9997545 DOI: 10.7759/cureus.34729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/07/2023] [Indexed: 02/10/2023] Open
Abstract
The aim of this meta-analysis is to assess the efficacy of extracorporeal shockwave therapy (ESWT) in patients with peripheral arterial disease (PAD). This meta-analysis was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A systematic search was conducted independently by two authors using PubMed, EMBASE, and Cochrane Central Register of Controlled Trials (CENTRAL) from inception to January 15, 2023. Primary clinical outcomes assessed in this meta-analysis were changes in maximum waking distance (MWD) and pain-free walking distance (PFWD) from baseline. Other outcomes assessed included change in ankle brachial pressure index (ABI) and degree of arterial stenosis. Four RCTs involving a total of 228 patients were included. Change of PFWD and MWD from baseline was significantly higher in patients randomized in the ESWT group as compared to the control group. No significant differences were reported between the two groups in terms of change in ABI from baseline. In conclusion, this meta-analysis of four randomized controlled trials found evidence that ESWT is an effective treatment for patients with PAD in terms of improving PFWD and MWD and reducing stenosis. However, there was no significant difference in the improvement of the ankle-brachial index between the study groups.
Collapse
Affiliation(s)
- Zaid Munir
- General Medicine, Withybush General Hospital, Cardiff, GBR
| | - Muhammad Akash
- Clinical Sciences, Mayo Hospital, King Edward Medical University, Lahore, PAK
| | - Fnu Jaiprada
- College of Medicine, Dow University of Health Sciences, Karachi, PAK
| | - Bilal Abu Tarboush
- Medicine, Universite Djillali Liabes Sidi Bel Abbes, Sidi Bel Abbès, DZA
| | - Osama Ijaz
- Internal Medicine, Services Institute of Medical Sciences, Lahore, PAK
| | - Anan Bseiso
- College of Medicine, Al-Quds University, Jerusalem, PSE.,College of Medicine, Hebron University, Hebron, PSE
| | | | - Adil Amin
- Cardiology, Pakistan Navy Station (PNS) Shifa, Karachi, PAK
| |
Collapse
|
9
|
Andreozzi E, Sabbadini R, Centracchio J, Bifulco P, Irace A, Breglio G, Riccio M. Multimodal Finger Pulse Wave Sensing: Comparison of Forcecardiography and Photoplethysmography Sensors. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22197566. [PMID: 36236663 PMCID: PMC9570799 DOI: 10.3390/s22197566] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 09/26/2022] [Accepted: 10/01/2022] [Indexed: 05/31/2023]
Abstract
Pulse waves (PWs) are mechanical waves that propagate from the ventricles through the whole vascular system as brisk enlargements of the blood vessels' lumens, caused by sudden increases in local blood pressure. Photoplethysmography (PPG) is one of the most widespread techniques employed for PW sensing due to its ability to measure blood oxygen saturation. Other sensors and techniques have been proposed to record PWs, and include applanation tonometers, piezoelectric sensors, force sensors of different kinds, and accelerometers. The performances of these sensors have been analyzed individually, and their results have been found not to be in good agreement (e.g., in terms of PW morphology and the physiological parameters extracted). Such a comparison has led to a deeper comprehension of their strengths and weaknesses, and ultimately, to the consideration that a multimodal approach accomplished via sensor fusion would lead to a more robust, reliable, and potentially more informative methodology for PW monitoring. However, apart from various multichannel and multi-site systems proposed in the literature, no true multimodal sensors for PW recording have been proposed yet that acquire PW signals simultaneously from the same measurement site. In this study, a true multimodal PW sensor is presented, which was obtained by integrating a piezoelectric forcecardiography (FCG) sensor and a PPG sensor, thus enabling simultaneous mechanical-optical measurements of PWs from the same site on the body. The novel sensor performance was assessed by measuring the finger PWs of five healthy subjects at rest. The preliminary results of this study showed, for the first time, that a delay exists between the PWs recorded simultaneously by the PPG and FCG sensors. Despite such a delay, the pulse waveforms acquired by the PPG and FCG sensors, along with their first and second derivatives, had very high normalized cross-correlation indices in excess of 0.98. Six well-established morphological parameters of the PWs were compared via linear regression, correlation, and Bland-Altman analyses, which showed that some of these parameters were not in good agreement for all subjects. The preliminary results of this proof-of-concept study must be confirmed in a much larger cohort of subjects. Further investigation is also necessary to shed light on the physical origin of the observed delay between optical and mechanical PW signals. This research paves the way for the development of true multimodal, wearable, integrated sensors and for potential sensor fusion approaches to improve the performance of PW monitoring at various body sites.
Collapse
|
10
|
Brahmbhatt A, Bryce Y, Hasan M, Pena C. Arterial Evaluation. Tech Vasc Interv Radiol 2022; 25:100866. [DOI: 10.1016/j.tvir.2022.100866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Amrani S, Eveilleau K, Fassbender V, Obeid H, Abi-Nasr I, Giordana P, Hallab M, Leftheriotis G. Assessment of the systolic rise time by photoplethysmography in peripheral arterial diseases: a comparative study with ultrasound Doppler. EUROPEAN HEART JOURNAL OPEN 2022; 2:oeac032. [PMID: 35919340 PMCID: PMC9242071 DOI: 10.1093/ehjopen/oeac032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 04/21/2022] [Accepted: 04/27/2022] [Indexed: 11/14/2022]
Abstract
Abstract
Aims
Peripheral arterial disease (PAD) is a major public health burden requiring more intensive population screening. Ankle brachial index (ABI) using arm and ankle cuffs is considered as the reference method for the detection of PAD. Although it requires a rigorous methodology by trained operators, it remains time-consuming and more technically difficult in patients with diabetes due to mediacalcosis. Techniques based on the study of hemodynamic, such as the systolic rise time (SRT), appear promising but need to be validated. We retrospectively compared the reliability and accuracy of SRT using a photoplethysmography (PPG) technique to the SRT measured by ultrasound doppler (UD) in PAD patients diagnosed with the ABI (137 patients, 200 lower limbs).
Methods and results
There was a significant correlation between SRT measured with UD (SRTud) compared with that with PPG (SRTppg, r = 0.25; P = 0.001). Best correlation was found in patients without diabetes (r = 0.40; P = 0.001). Bland and Altman analysis showed a good agreement between the SRTud and SRTppg. In contrast, there was no significant correlation between UD and PPG in diabetes patients. Furthermore, patients with diabetes exhibited a significant increase of SRTppg (P = 0.02) compared with patients without diabates but not with the SRTud (P = 0.18). The SRTppg was significantly linked to the arterial velocity waveforms, the type of arterial lesion but not vascular surgery revascularization technique.
Conclusion
This monocentric pilot study shows that SRT measured with the PPG signal reliably correlates with SRT recorded with UD. The PPG is an easy to use technique in the hand of non-expert with a potential interest for general screening of PAD, especially in diabetes patients, due to its ease to use.
Collapse
Affiliation(s)
- Samantha Amrani
- University Hospital of Nice, Vascular Medicine unit, Unité de Médecine et d’Explorations Vasculaires , CHU de Nice Pasteur 1, 30 voie Romaine Nice, France
| | | | - Verena Fassbender
- University Hospital of Nice, Vascular Medicine unit, Unité de Médecine et d’Explorations Vasculaires , CHU de Nice Pasteur 1, 30 voie Romaine Nice, France
| | - Hasan Obeid
- Clinique Bizet, Cardiology unit , Paris, France
| | | | - Pascal Giordana
- University Hospital of Nice, Vascular Medicine unit, Unité de Médecine et d’Explorations Vasculaires , CHU de Nice Pasteur 1, 30 voie Romaine Nice, France
| | | | - Georges Leftheriotis
- University Hospital of Nice, Vascular Medicine unit, Unité de Médecine et d’Explorations Vasculaires , CHU de Nice Pasteur 1, 30 voie Romaine Nice, France
| |
Collapse
|
12
|
Huthart S, Oates C, Allen J, Fiaschi K, Sims AJ, Stansby G. Validation of a Standardised Duplex Ultrasound Classification System for the Reporting and Grading of Peripheral Arterial Disease. Eur J Vasc Endovasc Surg 2022; 64:210-216. [PMID: 35472448 DOI: 10.1016/j.ejvs.2022.04.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 02/20/2022] [Accepted: 04/18/2022] [Indexed: 11/03/2022]
Abstract
INTRODUCTION Duplex ultrasound (DUS), a non-invasive means of arterial mapping, allows for reliable diagnosis of peripheral arterial disease (PAD). One of our authors (CPO), developed a standardised DUS-based scoring system, devised for rapid detection and reporting of PAD. The purpose of this study is to validate this system, determining diagnostic performance both overall, and per disease severity. METHODS 250 participants were recruited, based on diagnosis (N = 125), or absence of PAD (N = 125) from GP registers. Right and left legs per subject were handled as independent readings, determining actual PAD status via ABPI <0.9, and then further grading disease severity using suggested ABPI ranges. Data were excluded if no corresponding ABPI value was obtained per DUS-determination, or if the ABPI reading was >1.4, owing to risk of false negatives due to incompressible vessels. Diagnostic sensitivity and specificity were obtained overall, and per severity classification. Furthermore, interrater agreement between ABPI- and DUS-determined PAD severity was determined by linear weighted Cohen's Kappa. RESULTS The sensitivity and specificity in the detection of disease overall was 81.0% (95% CI 73.4 - 87.2%) and 86.3% (95% CI 82.3 - 89.8%), respectively. From mild to severe PAD, sensitivity increased from 71.1% (95% CI 55.7 - 83.6%) to 89.3% (95% CI 71.8 - 97.7%). Furthermore, a Cohen Kappa value of 0.63 (95% CI 0.57 - 0.69) was obtained, indicating moderate agreement between the two diagnostic methods. CONCLUSIONS Findings in this study validate the diagnostic performance of the standardised DUS scoring system, as well as its capacity to grade severity of disease, offering a potential tool for the identification of PAD in the community / research settings following initial screening methods. Confirmatory work could include a comparison of DUS-determined disease with gold-standard methods of non-invasive angiography, and novel tools such as toe-flex NIRS and multi-site photoplethysmography.
Collapse
Affiliation(s)
- Samuel Huthart
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, UK; Northern Medical Physics and Clinical Engineering Department, Freeman Hospital, Newcastle Upon Tyne, NE7 7DN, UK; Northern Vascular Centre, Freeman Hospital, Newcastle upon Tyne, NE7 7DN, UK.
| | - Crispian Oates
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, UK; Northern Medical Physics and Clinical Engineering Department, Freeman Hospital, Newcastle Upon Tyne, NE7 7DN, UK
| | - John Allen
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, UK; Northern Medical Physics and Clinical Engineering Department, Freeman Hospital, Newcastle Upon Tyne, NE7 7DN, UK; Research Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5RW, UK
| | - Kathia Fiaschi
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, UK; Northern Medical Physics and Clinical Engineering Department, Freeman Hospital, Newcastle Upon Tyne, NE7 7DN, UK; Northern Vascular Centre, Freeman Hospital, Newcastle upon Tyne, NE7 7DN, UK
| | - Andrew J Sims
- Northern Medical Physics and Clinical Engineering Department, Freeman Hospital, Newcastle Upon Tyne, NE7 7DN, UK
| | - Gerard Stansby
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, UK; Northern Medical Physics and Clinical Engineering Department, Freeman Hospital, Newcastle Upon Tyne, NE7 7DN, UK
| |
Collapse
|
13
|
Charlton PH, Paliakaitė B, Pilt K, Bachler M, Zanelli S, Kulin D, Allen J, Hallab M, Bianchini E, Mayer CC, Terentes-Printzios D, Dittrich V, Hametner B, Veerasingam D, Žikić D, Marozas V. Assessing hemodynamics from the photoplethysmogram to gain insights into vascular age: a review from VascAgeNet. Am J Physiol Heart Circ Physiol 2022; 322:H493-H522. [PMID: 34951543 PMCID: PMC8917928 DOI: 10.1152/ajpheart.00392.2021] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 12/21/2021] [Accepted: 12/21/2021] [Indexed: 12/07/2022]
Abstract
The photoplethysmogram (PPG) signal is widely measured by clinical and consumer devices, and it is emerging as a potential tool for assessing vascular age. The shape and timing of the PPG pulse wave are both influenced by normal vascular aging, changes in arterial stiffness and blood pressure, and atherosclerosis. This review summarizes research into assessing vascular age from the PPG. Three categories of approaches are described: 1) those which use a single PPG signal (based on pulse wave analysis), 2) those which use multiple PPG signals (such as pulse transit time measurement), and 3) those which use PPG and other signals (such as pulse arrival time measurement). Evidence is then presented on the performance, repeatability and reproducibility, and clinical utility of PPG-derived parameters of vascular age. Finally, the review outlines key directions for future research to realize the full potential of photoplethysmography for assessing vascular age.
Collapse
Affiliation(s)
- Peter H Charlton
- Department of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom
- Research Centre for Biomedical Engineering, University of London, London, United Kingdom
| | - Birutė Paliakaitė
- Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania
| | - Kristjan Pilt
- Department of Health Technologies, Tallinn University of Technology, Tallinn, Estonia
| | - Martin Bachler
- Biomedical Systems, Center for Health and Bioresources, AIT Austrian Institute of Technology, Seibersdorf, Austria
| | - Serena Zanelli
- Laboratoire Analyze, Géométrie et Applications, University Sorbonne Paris Nord, Paris, France
- Axelife, Redon, France
| | - Dániel Kulin
- Institute of Translational Medicine, Semmelweis University, Budapest, Hungary
- E-Med4All Europe, Limited, Budapest, Hungary
| | - John Allen
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, United Kingdom
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom
| | - Magid Hallab
- Axelife, Redon, France
- Centre de recherche et d'Innovation, Clinique Bizet, Paris, France
| | | | - Christopher C Mayer
- Biomedical Systems, Center for Health and Bioresources, AIT Austrian Institute of Technology, Seibersdorf, Austria
| | - Dimitrios Terentes-Printzios
- Hypertension and Cardiometabolic Unit, First Department of Cardiology, Hippokration Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Verena Dittrich
- Redwave Medical, Gesellschaft mit beschränkter Haftung, Jena, Germany
| | - Bernhard Hametner
- Biomedical Systems, Center for Health and Bioresources, AIT Austrian Institute of Technology, Seibersdorf, Austria
| | - Dave Veerasingam
- Department of Cardiothoracic Surgery, Galway University Hospitals, Galway, Ireland
| | - Dejan Žikić
- Faculty of Medicine, Institute of Biophysics, University of Belgrade, Belgrade, Serbia
| | - Vaidotas Marozas
- Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania
| |
Collapse
|
14
|
Park J, Seok HS, Kim SS, Shin H. Photoplethysmogram Analysis and Applications: An Integrative Review. Front Physiol 2022; 12:808451. [PMID: 35300400 PMCID: PMC8920970 DOI: 10.3389/fphys.2021.808451] [Citation(s) in RCA: 77] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 12/21/2021] [Indexed: 12/03/2022] Open
Abstract
Beyond its use in a clinical environment, photoplethysmogram (PPG) is increasingly used for measuring the physiological state of an individual in daily life. This review aims to examine existing research on photoplethysmogram concerning its generation mechanisms, measurement principles, clinical applications, noise definition, pre-processing techniques, feature detection techniques, and post-processing techniques for photoplethysmogram processing, especially from an engineering point of view. We performed an extensive search with the PubMed, Google Scholar, Institute of Electrical and Electronics Engineers (IEEE), ScienceDirect, and Web of Science databases. Exclusion conditions did not include the year of publication, but articles not published in English were excluded. Based on 118 articles, we identified four main topics of enabling PPG: (A) PPG waveform, (B) PPG features and clinical applications including basic features based on the original PPG waveform, combined features of PPG, and derivative features of PPG, (C) PPG noise including motion artifact baseline wandering and hypoperfusion, and (D) PPG signal processing including PPG preprocessing, PPG peak detection, and signal quality index. The application field of photoplethysmogram has been extending from the clinical to the mobile environment. Although there is no standardized pre-processing pipeline for PPG signal processing, as PPG data are acquired and accumulated in various ways, the recently proposed machine learning-based method is expected to offer a promising solution.
Collapse
Affiliation(s)
- Junyung Park
- Department of Biomedical Engineering, Chonnam National University, Yeosu, South Korea
| | - Hyeon Seok Seok
- Department of Biomedical Engineering, Chonnam National University, Yeosu, South Korea
| | - Sang-Su Kim
- Department of Biomedical Engineering, Chonnam National University, Yeosu, South Korea
| | - Hangsik Shin
- Department of Convergence Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| |
Collapse
|
15
|
Xiao M, Lu C, Ta N, Wei H, Yang C, Wu H. Toe PPG sample extension for supervised machine learning approaches to simultaneously predict type 2 diabetes and peripheral neuropathy. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2021.103236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
16
|
Validation of a new device for photoplethysmographic measurement of multi-site arterial pulse wave velocity. Biocybern Biomed Eng 2021. [DOI: 10.1016/j.bbe.2021.11.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
17
|
Di Rienzo M, Avolio A, Rizzo G, Zeybek ZMI, Cucugliato L. Multi-site Pulse Transit Times, Beat-to-Beat Blood Pressure, and Isovolumic Contraction Time at Rest and Under Stressors. IEEE J Biomed Health Inform 2021; 26:561-571. [PMID: 34347613 DOI: 10.1109/jbhi.2021.3101976] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This study investigates the beat-to-beat relationships among Pulse Transit Times (PTTs) and Pulse Arrival Times (PATs) concomitantly measured from the heart to finger, ear and forehead vascular districts, and their correlations with continuous finger blood pressure. These aspects were explored in 22 young volunteers at rest and during cold pressure test (CPT, thermal stress), handgrip (HG, isometric exercise) and cyclo-ergometer pedalling (CYC, dynamic exercise). The starting point of the PTT measures was the opening of the aortic valve detected by the seismocardiogram. Results indicate that PTTs measured at the ear, forehead and finger districts are uncorrelated each other at rest, and during CPT and HG. The stressors produced district-dependent changes in the PTT variability. Only the dynamic exercise was able to induce significant changes with respect to rest in the PTTs mean values (-40%, -36% and -17%, respectively for PTTear, PTTfore, PTTfinger,), and synchronize their modulations. Similar trends were observed in the PATs. The isovolumic contraction time decreased during the stressors application with a minimum at CYC (-25%) reflecting an augmented heart contractility. The increase in blood pressure (BP) at CPT was greater than that at CYC (137 vs. 128 mmHg), but the correlations between beat-to-beat transit times and BP were maximal at CYC (PAT showed a higher correlation than PTT; correlations were greater for systolic than for diastolic BP). This suggests that pulse transit times do not always depend directly on the beat-to-beat BP values but, under specific conditions, on other factors and mechanisms that concomitantly also influence BP.
Collapse
|
18
|
Karavaev AS, Borovik AS, Borovkova EI, Orlova EA, Simonyan MA, Ponomarenko VI, Skazkina VV, Gridnev VI, Bezruchko BP, Prokhorov MD, Kiselev AR. Low-frequency component of photoplethysmogram reflects the autonomic control of blood pressure. Biophys J 2021; 120:2657-2664. [PMID: 34087217 PMCID: PMC8390904 DOI: 10.1016/j.bpj.2021.05.020] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 04/18/2021] [Accepted: 05/17/2021] [Indexed: 11/30/2022] Open
Abstract
The question of how much information the photoplethysmogram (PPG) signal contains on the autonomic regulation of blood pressure (BP) remains unsolved. This study aims to compare the low-frequency (LF) and high-frequency components of PPG and BP and assess their correlation with oscillations in interbeat (RR) intervals at similar frequencies. The PPG signal from the distal phalanx of the right index finger recorded using a reflective PPG sensor at green light, the BP signal from the left hand recorded using a Finometer, and RR intervals were analyzed. These signals were simultaneously recorded within 15 min in a supine resting condition in 17 healthy subjects (12 males and 5 females) aged 33 ± 9 years (mean ± SD). The study revealed the high coherence of LF components of PPG and BP with the LF component of RR intervals. The high-frequency components of these signals had low coherence. The analysis of the signal instantaneous phases revealed the presence of high-phase coherence between the LF components of PPG and BP. It is shown that the LF component of PPG is determined not only by local myogenic activity but also reflects the processes of autonomic control of BP.
Collapse
Affiliation(s)
- Anatoly S Karavaev
- Saratov State Medical University, Saratov, Russia; Saratov Branch of the Institute of Radio-Engineering and Electronics of Russian Academy of Sciences, Saratov, Russia; Saratov State University, Saratov, Russia
| | - Anatoly S Borovik
- Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| | - Ekaterina I Borovkova
- Saratov State Medical University, Saratov, Russia; Saratov State University, Saratov, Russia
| | - Eugeniya A Orlova
- Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| | | | - Vladimir I Ponomarenko
- Saratov Branch of the Institute of Radio-Engineering and Electronics of Russian Academy of Sciences, Saratov, Russia; Saratov State University, Saratov, Russia
| | | | - Vladimir I Gridnev
- Saratov State Medical University, Saratov, Russia; Saratov State University, Saratov, Russia
| | - Boris P Bezruchko
- Saratov Branch of the Institute of Radio-Engineering and Electronics of Russian Academy of Sciences, Saratov, Russia; Saratov State University, Saratov, Russia
| | - Mikhail D Prokhorov
- Saratov Branch of the Institute of Radio-Engineering and Electronics of Russian Academy of Sciences, Saratov, Russia
| | - Anton R Kiselev
- Saratov State Medical University, Saratov, Russia; National Medical Research Center for Therapy and Preventive Medicine, Moscow, Russia.
| |
Collapse
|
19
|
Allen J, Liu H, Iqbal S, Zheng D, Stansby G. Deep learning-based photoplethysmography classification for peripheral arterial disease detection: a proof-of-concept study. Physiol Meas 2021; 42. [PMID: 33878743 DOI: 10.1088/1361-6579/abf9f3] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Accepted: 04/20/2021] [Indexed: 11/12/2022]
Abstract
Objective.A proof-of-concept study to assess the potential of a deep learning (DL) based photoplethysmography PPG ('DLPPG') classification method to detect peripheral arterial disease (PAD) using toe PPG signals.Approach.PPG spectrogram images derived from our previously published multi-site PPG datasets (214 participants; 31.3% legs with PAD by ankle brachial pressure index (ABPI)) were input into a pretrained 8-layer (five convolutional layers + three fully connected layers) AlexNet as tailored to the 2-class problem with transfer learning to fine tune the convolutional neural network (CNN).k-fold random cross validation (CV) was performed (fork = 5 andk = 10), with each evaluated over k training/validation runs. Overall test sensitivity, specificity, accuracy, and Cohen's Kappa statistic with 95% confidence interval ranges were calculated and compared, as well as sensitivities in detecting mild-moderate (0.5 ≤ ABPI < 0.9) and major (ABPI < 0.5) levels of PAD.Main results.CV with eitherk = 5 or 10 folds gave similar diagnostic performances. The overall test sensitivity was 86.6%, specificity 90.2% and accuracy 88.9% (Kappa: 0.76 [0.70-0.82]) (atk= 5). The sensitivity to mild-moderate disease was 83.0% (75.5%-88.9%) and to major disease was 100.0% (90.5%-100.0%).Significance.Substantial agreements have been demonstrated between the DL-based PPG classification technique and the ABPI PAD diagnostic reference. This novel automatic approach, requiring minimal pre-processing of the pulse waveforms before PPG trace classification, could offer significant benefits for the diagnosis of PAD in a variety of clinical settings where low-cost, portable and easy-to-use diagnostics are desirable.
Collapse
Affiliation(s)
- John Allen
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom.,Research Centre for Intelligent Healthcare, Coventry University, United Kingdom.,Northern Regional Medical Physics Department, Freeman Hospital, Newcastle upon Tyne, United Kingdom
| | - Haipeng Liu
- Research Centre for Intelligent Healthcare, Coventry University, United Kingdom
| | - Sadaf Iqbal
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom.,Northern Regional Medical Physics Department, Freeman Hospital, Newcastle upon Tyne, United Kingdom
| | - Dingchang Zheng
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom.,Research Centre for Intelligent Healthcare, Coventry University, United Kingdom
| | - Gerard Stansby
- Northern Vascular Centre, Freeman Hospital, Newcastle upon Tyne. United Kingdom
| |
Collapse
|
20
|
Luo K, Liu X, Li J, Ma Y, Ye Q, Bai J, Liang C, Zou F. Redundant Gaussian dictionary in compressed sensing for ambulatory photoplethysmography monitoring. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
|
21
|
Huthart S, Elgendi M, Zheng D, Stansby G, Allen J. Advancing PPG Signal Quality and Know-How Through Knowledge Translation—From Experts to Student and Researcher. Front Digit Health 2020; 2:619692. [PMID: 34713077 PMCID: PMC8521847 DOI: 10.3389/fdgth.2020.619692] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 11/24/2020] [Indexed: 11/19/2022] Open
Abstract
Objective: Despite the vast number of photoplethysmography (PPG) research publications and growing demands for such sensing in Digital and Wearable Health platforms, there appears little published on signal quality expectations for morphological pulse analysis. Aim: to determine a consensus regarding the minimum number of undistorted i.e., diagnostic quality pulses required, as well as a threshold proportion of noisy beats for recording rejection. Approach: Questionnaire distributed to international fellow researchers in skin contact PPG measurements on signal quality expectations and associated factors concerning recording length, expected artifact-free pulses (“diagnostic quality”) in a trace, proportion of trace having artifact to justify excluding/repeating measurements, minimum beats required, and number of respiratory cycles. Main Results: 18 (of 26) PPG researchers responded. Modal range estimates considered a 2-min recording time as target for morphological analysis. Respondents expected a recording to have 86–95% of diagnostic quality pulses, at least 11–20 sequential pulses of diagnostic quality and advocated a 26–50% noise threshold for recording rejection. There were broader responses found for the required number of undistorted beats (although a modal range of 51–60 beats for both finger and toe sites was indicated). Significance: For morphological PPG pulse wave analysis recording acceptability was indicated if <50% of beats have artifact and preferably that a minimum of 50 non-distorted PPG pulses are present (with at least 11–20 sequential) to be of diagnostic quality. Estimates from this knowledge transfer exercise should help inform students and researchers as a guide in standards development for PPG study design.
Collapse
Affiliation(s)
- Samuel Huthart
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom
| | - Mohamed Elgendi
- Department of Obstetrics and Gynaecology, University of British Columbia, Vancouver, BC, Canada
| | - Dingchang Zheng
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, United Kingdom
| | - Gerard Stansby
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom
- Northern Vascular Centre, Freeman Hospital, Newcastle upon Tyne, Unite Kingdom
| | - John Allen
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, United Kingdom
- Northern Medical Physics and Clinical Engineering Department, Freeman Hospital, Newcastle upon Tyne, United Kingdom
- *Correspondence: John Allen
| |
Collapse
|
22
|
Shin H, Park J, Seok HS, Kim SS. Photoplethysmogram analysis and applications: An Integrative Review (Preprint). JMIR BIOMEDICAL ENGINEERING 2020. [DOI: 10.2196/25567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
23
|
Physiological Monitoring and Hearing Loss: Toward a More Integrated and Ecologically Validated Health Mapping. Ear Hear 2020; 41 Suppl 1:120S-130S. [DOI: 10.1097/aud.0000000000000960] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
24
|
Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR). BIOSENSORS-BASEL 2020; 10:bios10040034. [PMID: 32260393 PMCID: PMC7235881 DOI: 10.3390/bios10040034] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 04/01/2020] [Accepted: 04/02/2020] [Indexed: 11/30/2022]
Abstract
Photoplethysmography (PPG) is a valuable technique for noninvasively evaluating physiological parameters. However, traditional PPG devices have significant limitations in high-motion and low-perfusion environments. To overcome these limitations, we investigated the accuracy of a clinically novel PPG site using SPYDR®, a new PPG sensor suite, against arterial blood gas (ABG) measurements as well as other commercial PPG sensors at the finger and forehead in hypoxic environments. SPYDR utilizes a reflectance PPG sensor applied behind the ear, between the pinna and the hairline, on the mastoid process, above the sternocleidomastoid muscle, near the posterior auricular artery in a self-contained ear cup system. ABG revealed accuracy of SPYDR with a root mean square error of 2.61% at a 70–100% range, meeting FDA requirements for PPG sensor accuracy. Subjects were also instrumented with SPYDR, as well as finger and forehead PPG sensors, and pulse rate (PR) and oxygen saturation (SpO2) were measured and compared at various reduced oxygen profiles with a reduced oxygen breathing device (ROBD). SPYDR was shown to be as accurate as other sensors in reduced oxygen environments with a Pearson’s correlation >93% for PR and SpO2. In addition, SPYDR responded to changes in SpO2 up to 50 s faster than PPG measurements at the finger and forehead.
Collapse
|
25
|
Fan W, Yang B, Liang N, Liang S. Extracorporeal shockwave therapy for peripheral arterial disease. Hippokratia 2019. [DOI: 10.1002/14651858.cd013509] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Weijing Fan
- Beijing University of Chinese Medicine; Dongfang Hospital Affiliated to Beijing University of Chinese Medicine Beijing 北京 China 100029
| | - Baozhong Yang
- Dongfang Hospital of Beijing University of Chinese Medicine; Vascular Department; No 6, District 1, Fangxingyuan Beijing China
| | - Ning Liang
- Beijing University of Chinese Medicine; Centre for Evidence-Based Chinese Medicine; Bei San Huan Dong Lu 11, Chaoyang District Beijing China 100029
| | - Shibing Liang
- Shanxi University of Traditional Chinese Medicine; School of Basic Medicine; Jinci road, Wan Bailin district Taiyuan Shanxi Province China 030000
| |
Collapse
|
26
|
Allen J. Quantifying the Delays Between Multi-Site Photoplethysmography Pulse and Electrocardiogram R-R Interval Changes Under Slow-Paced Breathing. Front Physiol 2019; 10:1190. [PMID: 31607946 PMCID: PMC6774289 DOI: 10.3389/fphys.2019.01190] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 09/03/2019] [Indexed: 12/05/2022] Open
Abstract
Objective: Objective assessment of autonomic function is important, including the investigation of slow-paced breathing to induce associated periodic changes in the cardiovascular system – such as blood pressure and heart rate. However, pulse changes across a range of peripheral body sites have seldom been explored with this challenge. The primary aim of this pilot study was to utilize multi-site photoplethysmography (MPPG) technology to quantify the phase delays, i.e., correlation lags, between changes in heart rate and changes in key pulse features with slow-paced breathing (0.1 Hz). Methods: Waveforms were collected simultaneously from the right and left ear lobes, thumbs, and great toes of 18 healthy adult subjects. Cross correlation lags between reference beat-to-beat changes in electrocardiogram (ECG) R-R wave interval and changes in pulse arrival time (foot of pulse; PATf) and also for pulse amplitude (foot-to-peak; AMP) were determined. Results: Relative to R-R changes, the median ear, thumb, and toe PATf correlation lags were 3.4, 2.9, and 2.1 beats, respectively; contrasting to AMP with 5.7, 6.0, and 6.9 beats, respectively. These PATf correlation lags in beats were significantly lower than for the AMP measure. Segmental differences between sites and timing measure variability have also been quantified. Conclusion: This pilot study has indicated bilateral similarity plus segmental differences for relative delays in PPG pulse timing and amplitude measures relative to R-R interval changes with paced breathing. These correlation and variability data are now available for comparison with cardiovascular patient groups to support development of autonomic function assessment techniques.
Collapse
Affiliation(s)
- John Allen
- Microvascular Diagnostics, Northern Medical Physics and Clinical Engineering Department, Freeman Hospital, Newcastle upon Tyne, United Kingdom.,Faculty of Medical Sciences, Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, United Kingdom
| |
Collapse
|
27
|
Hartmann V, Liu H, Chen F, Hong W, Hughes S, Zheng D. Toward Accurate Extraction of Respiratory Frequency From the Photoplethysmogram: Effect of Measurement Site. Front Physiol 2019; 10:732. [PMID: 31316390 PMCID: PMC6611405 DOI: 10.3389/fphys.2019.00732] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 05/27/2019] [Indexed: 12/28/2022] Open
Abstract
Background: It is known that the respiration-modulated photoplethysmographic (PPG) signals could be used to derive respiratory frequency (RF) and that PPG signals could be measured from different body sites. However, the accuracy of RF derived from PPG signals of different body sites has not been comprehensively investigated. Objective: This study aims to investigate the difference in the accuracy of PPG-derived RFs between measurements from different body sites, respectively, for normal and deep breathing conditions. Methods: Under normal and deep breathing patterns, the PPG signals were recorded sequentially in a randomized order from six body sites [finger, wrist under (anatomically volar), wrist upper (dorsal), earlobe, and forehead] of 36 healthy subjects. Simultaneously, the reference respiratory signal was measured by a respiratory belt on the chest. Using the frequency demodulation approach, respiratory signals were extracted from PPG signals for calculating RF by power spectral density. The bias between PPG-derived and reference RFs was then analyzed statistically using analysis of variance and non-parametric tests, Bland-Altman analysis, and linear regression to investigate the difference in RF bias between different sites. Results: The RF bias was significantly influenced by the breathing pattern and measurement site (both p < 0.001). Under normal breathing, the RF bias was insignificant in the arm, forehead, and wrist under (all p > 0.05) and significant in the other sites (all p < 0.05). Significant linear relationship between PPG-derived and reference RFs existed at all the sites (p < 0.001) except the wrist upper (p > 0.05). The linearity between PPG-derived and reference RFs was highest at the forehead (slope of best-fit line: 0.90, R2: 0.64), followed by the earlobe, finger, arm, and wrist under (slope: 0.71, R2: 0.40). Under deep breathing, there was no significant RF bias in all the measurement sites (p > 0.05) except forehead (p = 0.048). The effect of measurement site on RF bias was not significant (p > 0.05). The finger had the smallest RF bias and the narrowest limits of agreement. Conclusion: This study has demonstrated that the accuracy of PPG-derived RF depends on the measurement site and breathing pattern. The best sites are the forehead and finger, respectively, for normal and deep breathing patterns.
Collapse
Affiliation(s)
- Vera Hartmann
- School of Allied Health, Faculty of Health, Education, Medicine, and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom
| | - Haipeng Liu
- School of Allied Health, Faculty of Health, Education, Medicine, and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom
| | - Fei Chen
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, China
| | - Wentao Hong
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, China
| | - Stephen Hughes
- School of Allied Health, Faculty of Health, Education, Medicine, and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom
| | - Dingchang Zheng
- School of Allied Health, Faculty of Health, Education, Medicine, and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom
| |
Collapse
|
28
|
Hartmann V, Liu H, Chen F, Qiu Q, Hughes S, Zheng D. Quantitative Comparison of Photoplethysmographic Waveform Characteristics: Effect of Measurement Site. Front Physiol 2019; 10:198. [PMID: 30890959 PMCID: PMC6412091 DOI: 10.3389/fphys.2019.00198] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 02/15/2019] [Indexed: 11/13/2022] Open
Abstract
Introduction: Photoplethysmography (PPG) has been widely used to assess cardiovascular function. However, few studies have comprehensively investigated the effect of measurement site on PPG waveform characteristics. This study aimed to provide a quantitative comparison on this. Methods: Thirty six healthy subjects participated in this study. For each subject, PPG signals were sequentially recorded for 1 min from six different body sites (finger, wrist under (anatomically volar), wrist upper (dorsal), arm, earlobe, and forehead) under both normal and deep breathing patterns. For each body site under a certain breathing pattern, the mean amplitude was firstly derived from recorded PPG waveform which was then normalized to derive several waveform characteristics including the pulse peak time (Tp), dicrotic notch time (Tn), and the reflection index (RI). The effects of breathing pattern and measurement site on the waveform characteristics were finally investigated by the analysis of variance (ANOVA) with post hoc multiple comparisons. Results: Under both breathing patterns, the PPG measurements from the finger achieved the highest percentage of analyzable waveforms for extracting waveform characteristics. There were significant effects of breathing pattern on Tn and RI (larger Tn and smaller RI with deep breathing on average, both p < 0.03). The effects of measurement site on mean amplitude, Tp, Tn, and RI were significant (all p < 0.001). The key results were that, under both breathing patterns, the mean amplitude from finger PPG was significantly larger and its Tp and RI were significantly smaller than those from the other five sites (all p < 0.001, except p = 0.04 for the Tp of "wrist under"), and Tn was only significantly larger than that from the earlobe (both p < 0.05). Conclusion: This study has quantitatively confirmed the effect of PPG measurement site on PPG waveform characteristics (including mean amplitude, Tp, Tn, and RI), providing scientific evidence for a better understanding of the PPG waveform variations between different body sites.
Collapse
Affiliation(s)
- Vera Hartmann
- Faculty of Health, Education, Medicine and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom
| | - Haipeng Liu
- Faculty of Health, Education, Medicine and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom.,Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, China
| | - Fei Chen
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, China
| | - Qian Qiu
- Faculty of Health, Education, Medicine and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom
| | - Stephen Hughes
- Faculty of Health, Education, Medicine and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom
| | - Dingchang Zheng
- Faculty of Health, Education, Medicine and Social Care, Anglia Ruskin University, Chelmsford, United Kingdom
| |
Collapse
|