1
|
İnce Kuka G, Gürsoy H. Root surface roughness evaluation following application of different periodontal instruments and Er:YAG laser: A profilometry and SEM study. Lasers Med Sci 2024; 39:98. [PMID: 38583109 PMCID: PMC10999381 DOI: 10.1007/s10103-024-04025-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 02/13/2024] [Indexed: 04/08/2024]
Abstract
AIM The aim of the present study was to evaluate the efficacy of 30°-angled Er:YAG laser tip and different periodontal instruments on root surface roughness and morphology in vitro. METHODS Eighteen bovine teeth root without carious lesion were decoronated from the cementoenamel junction and seperated longitidunally. A total of 36 obtained blocks were mounted in resin blocks and polished with silicon carbide papers under water irrigation. These blocks were randomly assigned into 3 treatment groups. In Group 1, 30°-angled Er:YAG laser (2.94 μm) tip was applied onto the blocks with a 20 Hz, 120 mJ energy output under water irrigation for 20 s. In Groups 2 and 3, the same treatment was applied to the blocks with new generation ultrasonic tip and conventional curette apico-coronally for 20 s with a sweeping motion. Surface roughness and morphology were evaluated before and after instrumentation with a profilometer and SEM, respectively. RESULTS After instrumentation, profilometric analysis revealed significantly higher roughness values compared to baseline in all treatment groups(p < 0.05). Laser group revealed the roughest surface morphology followed by conventional curette and new generation ultrasonic tip treatment groups (p < 0.05). In SEM analysis, irregular surfaces and crater defects were seen more frequently in the laser group. CONCLUSION Results of the study showed that the use of new generation ultrasonic tip was associated with smoother surface morphology compared to 30°-angled Er-YAG laser tip and conventional curette. Further in vitro and in vivo studies with an increased sample size are necessary to support the present study findings.
Collapse
Affiliation(s)
- Gizem İnce Kuka
- Department of Periodontology, Hamidiye Dental Faculty, University of Health Sciences, Istanbul, Turkey.
| | - Hare Gürsoy
- Department of Periodontology, Hamidiye Dental Faculty, University of Health Sciences, Istanbul, Turkey
| |
Collapse
|
2
|
You X, Wu X, Chen S. Effects of a new magnetostrictive ultrasonic scaler and a traditional piezoelectric ultrasonic scaler on root surfaces and patient complaints. Sci Rep 2024; 14:6601. [PMID: 38503814 PMCID: PMC10951197 DOI: 10.1038/s41598-024-57037-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 03/13/2024] [Indexed: 03/21/2024] Open
Abstract
Tooth wear and pain are the primary concerns of patients undergoing periodontal scaling. The aims of this study were to compare the effects of a new magnetostrictive ultrasonic scaler and a traditional piezoelectric ultrasonic scaler on tooth surface roughness and calculus removal and to determine their impacts on patient discomfort during supragingival cleaning. This article had two parts: an in vitro study and a clinical study. In the in vitro study, thirty teeth with subgingival calculus were randomly assigned to two scaling treatment groups: magnetostrictive scalers (n = 15) and piezoelectric scalers (n = 15). Surface roughness measurements were taken at baseline and after scaling, and the root samples were visualised by SEM after scaling. Additionally, a single-centre randomised split-mouth clinical trial was conducted. Eighty-five participants diagnosed with chronic gingivitis or periodontitis were randomly assigned to receive supragingival scaling. The magnetostrictive scaler was used in half of the mouths (n = 85), and the piezoelectric scaler was used in the other half of the mouths (n = 85). Data on pain, noise, and vibration were collected using a VAS questionnaire, and the operating time was recorded. In both in vitro and clinical studies, magnetostrictive scalers were reported to be more effective than piezoelectric scalers in removing dental deposits (P < 0.05). Additionally, the root surface after scaling with the magnetostrictive scaler was smoother than that after scaling with the piezoelectric scaler in the in vitro study (P = 0.02). SEM examination also revealed that fewer dental materials were lost after instrumentation with the magnetostrictive scaler than after instrumentation with the piezoelectric scaler. Piezoelectric scalers caused less discomfort to patients in terms of pain, noise, and vibration than magnetostrictive scalers (P < 0.05). According to this clinical study, the magnetostrictive scaler caused more discomfort during supragingival scaling than the piezoelectric scaler. Moreover, the magnetostrictive scaler was also more efficient and produced a smoother root surface with less material loss after scaling than the piezoelectric scaler, as demonstrated in the in vitro study.
Collapse
Affiliation(s)
- Xiaoqing You
- Fujian Biological Materials Engineering and Technology Center of Stomatology, School and Hospital of Stomatology, Fujian Medical University, 246 Yangqiao Zhong Rd, Fuzhou, 350002, Fujian, China
| | - Xiaohong Wu
- Fujian Biological Materials Engineering and Technology Center of Stomatology, School and Hospital of Stomatology, Fujian Medical University, 246 Yangqiao Zhong Rd, Fuzhou, 350002, Fujian, China
| | - Shiwei Chen
- Fujian Biological Materials Engineering and Technology Center of Stomatology, School and Hospital of Stomatology, Fujian Medical University, 246 Yangqiao Zhong Rd, Fuzhou, 350002, Fujian, China.
| |
Collapse
|
3
|
Sabatini S, Maiorani C, Bassignani J, Cotellessa S, Di Trani G, Fulgenzi E, Iacono R, Mercogliano I, Butera A. Effectiveness of Ultrasonic and Manual Instrumentation in Nonsurgical Periodontal Therapy: Are Additional Therapies More Effective? A Systematic Review. APPLIED SCIENCES 2024; 14:1950. [DOI: 10.3390/app14051950] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
Nonsurgical periodontal therapy aims to remove supragingival and subgingival biofilm to restore periodontal health. This systematic review aims to assess the clinical effectiveness of manual and/or ultrasonic instruments and to determine whether other therapies can improve periodontal clinical outcomes. Case-control, cross-sectional and cohort studies and clinical trials of patients undergoing nonsurgical periodontal therapy with ultrasonic and/or manual instruments (and any adjunctive therapies, such as glycine, erythritol, ozone, laser and glycine) from 2013 to 2023 were analyzed using Pub-med/MEDLINE, Scopus and Google Scholar. To assess the risk of bias in this review, blinding, randomization, allocation concealment, outcome data and outcome recording were assessed. No differences between treatments were found; all methods, including manual and ultrasound, were helpful in improving clinical parameters (primary outcome). Although the results were mixed, adjunctive therapies seemed to be helpful in the treatment of periodontal disease. The results of this systematic review are consistent with the previous scientific literature and have shown that both manual and ultrasonic instruments are effective in nonsurgical periodontal therapy. This review could not show how complementary therapies could further improve nonsurgical periodontal therapy. For future research, it would be good to standardize the sample with regard to the degree and stage of periodontal disease and to evaluate the risks and benefits of the instruments (manual and ultrasonic scalers).
Collapse
Affiliation(s)
- Silvia Sabatini
- Italian Society of Oral Hygiene Sciences (SISIO), 66034 Lanciano, Italy
- Department of Surgical, Medical, Dental and Morphological Sciences, University of Modena and Reggio Emilia, 41124 Modena, Italy
| | - Carolina Maiorani
- Italian Society of Oral Hygiene Sciences (SISIO), 66034 Lanciano, Italy
- Unit of Dental Hygiene, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
| | | | - Silvia Cotellessa
- Italian Society of Oral Hygiene Sciences (SISIO), 66034 Lanciano, Italy
| | - Giuseppe Di Trani
- Italian Society of Oral Hygiene Sciences (SISIO), 66034 Lanciano, Italy
| | - Elisa Fulgenzi
- Italian Society of Oral Hygiene Sciences (SISIO), 66034 Lanciano, Italy
| | - Roberta Iacono
- Italian Society of Oral Hygiene Sciences (SISIO), 66034 Lanciano, Italy
| | | | - Andrea Butera
- Italian Society of Oral Hygiene Sciences (SISIO), 66034 Lanciano, Italy
- Unit of Dental Hygiene, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
| |
Collapse
|
4
|
Parashar A, Bhavsar N. Assessing the effect of piezoelectric ultrasonic scaler tip wear on root surface roughness under influence of various working parameters: A profilometric and atomic force microscopic study. J Indian Soc Periodontol 2023; 27:583-589. [PMID: 38434510 PMCID: PMC10906801 DOI: 10.4103/jisp.jisp_416_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 05/03/2023] [Accepted: 10/22/2023] [Indexed: 03/05/2024] Open
Abstract
Background Assessing the effect of scaler tip wear on the root surface roughness using piezoelectric ultrasonic scaling device under influence of various working parameters, i.e. power setting, lateral force, and instrumentation time. Materials and Methods An experimental study was conducted using 160 single-rooted tooth samples divided into two groups of new (n = 80) and worn tips (n = 80). Samples were prepared to examine the root surface roughness after being instrumented by new and worn piezoelectric ultrasonic tips (8 new/8 worn) at different parameters. The erosion ratio (ER) of the new/worn tip was examined under an atomic force microscope and roughness over root surface was measured by a contact surface profilometer. One-way analysis of variance test, post hoc Tukey's test, and independent t-test were used for intragroup, pair-wise multiple comparisons and intergroup comparison of average roughness (Ra) value. Results A statistically significant difference was found between the ER of new and worn scaler tips (P < 0.001). Intragroup comparison between subgroups 1 and 8 showed a higher Ra value in both the groups (P < 0.005). There was a significantly higher Ra value of worn tips compared to new tips (P < 0.05). Significantly higher mean Ra value was shown when lateral force changed from 50 g to 100 g (P < 0.005). Conclusions Increasing value of power setting, lateral force, and instrumentation time caused more surface roughness in worn-out scaler tips compared to new scaler tips. Lateral force and instrumentation time proved to be a major factor influencing surface roughness.
Collapse
Affiliation(s)
- Atul Parashar
- Department of Periodontology, Government Dental College and Hospital, Ahmedabad, Gujarat, India
| | - Neeta Bhavsar
- Department of Periodontology, Government Dental College and Hospital, Ahmedabad, Gujarat, India
| |
Collapse
|
5
|
Vaziri F, Rashidi Maybodi F, Arab Farashahi M. Evaluation of root surface roughness produced by hand instruments and ultrasonic scalers: An in vivo study. JOURNAL OF ADVANCED PERIODONTOLOGY & IMPLANT DENTISTRY 2022; 14:84-88. [PMID: 36714085 PMCID: PMC9871177 DOI: 10.34172/japid.2022.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 10/22/2022] [Indexed: 01/09/2023]
Abstract
Background. The aim of periodontal treatment is to remove bacterial plaque and dental calculus by hand and power-driven instruments. However, the comparison of the effectiveness of these instruments has always been controversial. Therefore, this in vivo study investigated and compared the effects of hand and ultrasonic piezoelectric instruments on the roughness of dental surfaces under an atomic force microscope (AFM). Methods. In this study, 35 periodontally hopeless teeth were selected and randomly divided into four groups (n=7). The control group consisted of teeth that had to be extracted for orthodontic or prosthetic treatment (n=7). In group one, scaling and root planing were performed using hand instruments. In other groups, scaling and root planing were performed using piezoelectric ultrasonic instruments with low to high power, respectively. Then the scaled teeth were extracted for analysis under an atomic force microscope. Results. This study showed that root roughness significantly differed between different experimental groups (P<0.027). The root roughness (Rq) in the SRP2 group significantly differed from the control group (P<0.05), while no significant differences were observed between the other groups. Furthermore, the least roughness was observed in the SRP3 group, with the highest roughness in the SRP2 group. Conclusion. Within the limitation of this study, there were no significant differences in surface roughness between different powers of the ultrasonic device.
Collapse
Affiliation(s)
- Farzane Vaziri
- Periodontology Department, Faculty of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Fahimeh Rashidi Maybodi
- Periodontology Department, Faculty of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Mohammad Arab Farashahi
- Periodontology Department, Faculty of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran,Corresponding author: Mohammad Arab Farashahi, E-mail:
| |
Collapse
|
6
|
Analysing root roughness and smear layer relationship by comparing contemporary dental curettes with conventional dental curettes: a randomised controlled trial. BMC Oral Health 2022; 22:237. [PMID: 35715802 PMCID: PMC9206281 DOI: 10.1186/s12903-022-02268-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 06/07/2022] [Indexed: 11/15/2022] Open
Abstract
Background Root debridement procedures for the treatment of periodontal diseases, produces root surface irregularities and smear layer on the root surface that can adversely affect the healing of periodontal tissues. The objective of the present study was to evaluate the surface texture of root after hand instrumentation with Gracey curette, After Five curette, and Mini Five curette. Methods A randomised, controlled clinical trial was conducted with 120 participants clinically diagnosed with chronic periodontitis. Participants were equally randomised into four groups, with parallel treatment assignment of scaling and root planning using Gracey Curettes, After five and Mini five curette, and a control group with no instrumentation. Mobile teeth of these patients were then extracted atraumatically and analysed under a Scanning Electron Microscope and graded for "Roughness and Loss of Tooth substance index" and "Smear layer index." Cross Tabulation was made between the test groups (Control, Gracey Curette, After five, and Mini Five) versus "Roughness and Loss of Tooth substance Index" and "Smear Layer Index." A Chi-square test with Bonferroni correction was used to determine the graded distribution among the groups. Results In the control group, 73.3% of the teeth showed grade 1 roughness. In the Gracey group, 56.7% showed grade 2 roughness; in the After 5 group, 70% showed grade 3 roughness; in the Mini 5 group, 76.7% showed grade 3 roughness. A significant association was found between roughness scores and the use of individual instruments. Regarding smear layer formation, 46.7% of teeth showed a grade 4 smear layer in the control group. 50% of teeth showed grade 2 smear layer thickness in the Gracey group. In the After 5 group, 73.3% of teeth showed a grade 1 smear layer, while in the Mini 5 group, 80.0% showed a grade 1 smear layer. The use of individual instruments was significantly associated with the smear layer scores. Conclusion Gracey curettes produced relatively smoother root surfaces with less smear layer formation than After Five and Mini Five curettes, which produced relatively more roughened root surfaces with thicker smear layer formation. Trial registration ID: ClinicalTrials.gov Identifier: NCT04216966 Date of Registration: January 3, 2020.
Collapse
|
7
|
Babina K, Polyakova M, Sokhova I, Doroshina V, Arakelyan M, Zaytsev A, Novozhilova N. The Effect of Ultrasonic Scaling and Air-Powder Polishing on the Roughness of the Enamel, Three Different Nanocomposites, and Composite/Enamel and Composite/Cementum Interfaces. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:3072. [PMID: 34835835 PMCID: PMC8623571 DOI: 10.3390/nano11113072] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 11/06/2021] [Accepted: 11/13/2021] [Indexed: 11/20/2022]
Abstract
We aimed to assess the effects of ultrasonic scaling and air-powder polishing on the roughness of enamel, three nanocomposites (Premise, Herculite Ultra, Harmonize), and composite/enamel and composite/cementum interfaces. Class V cavities were restored in 99 extracted third molars with one of the three nanocomposites and treated with ultrasonic scaler or air-powder polishing device (calcium carbonate or sodium bicarbonate powders). The roughness (Ra) of the investigated surfaces was measured with contact profilometer before and after treatment. The data were analyzed using repeated measures ANOVA. Specimens' Ra values before instrumentation were near the clinically acceptable 0.2 μm threshold. All techniques increased the roughness of the tested surfaces; however, the enamel was slightly affected. The mean Ra values after prophylaxis for composite, composite/cementum and composite/enamel surfaces were 0.32-0.55, 1.33-1.73, and 1.25-1.36, respectively. The extent of composite surface damage was material dependent. Premise surface was not altered by ultrasonic scaling significantly. Air-powder polishing with both powders produced a greater increase in surface roughness of composite resin and restorations margins than ultrasonic scaling. The Ra values after both types of air polishing for Herculite Ultra and Harmonize were approximately 1.5 and 2 times higher, respectively, than those after ultrasonic scaling (p < 0.05).
Collapse
Affiliation(s)
- Ksenia Babina
- Department of Therapeutic Dentistry, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia; (M.P.); (I.S.); (V.D.); (M.A.); (N.N.)
| | - Maria Polyakova
- Department of Therapeutic Dentistry, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia; (M.P.); (I.S.); (V.D.); (M.A.); (N.N.)
| | - Inna Sokhova
- Department of Therapeutic Dentistry, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia; (M.P.); (I.S.); (V.D.); (M.A.); (N.N.)
| | - Vladlena Doroshina
- Department of Therapeutic Dentistry, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia; (M.P.); (I.S.); (V.D.); (M.A.); (N.N.)
| | - Marianna Arakelyan
- Department of Therapeutic Dentistry, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia; (M.P.); (I.S.); (V.D.); (M.A.); (N.N.)
| | - Alexandr Zaytsev
- Institute of Linguistics and Intercultural Communication, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia;
| | - Nina Novozhilova
- Department of Therapeutic Dentistry, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia; (M.P.); (I.S.); (V.D.); (M.A.); (N.N.)
| |
Collapse
|