1
|
Khurana S, Das S, Frishman WH, Aronow WS, Frenkel D. Lead Extraction-Indications, Procedure, and Future Directions. Cardiol Rev 2025; 33:212-218. [PMID: 37729602 DOI: 10.1097/crd.0000000000000610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
Cardiac implantable electronic device (CIED) implantation has steadily increased in the United States owing to increased life expectancy, better access to health care, and the adoption of updated guidelines. Transvenous lead extraction (TLE) is an invasive technique for the removal of CIED devices, and the most common indications include device infections, lead failures, and venous occlusion. Although in-hospital and procedure-related deaths for patients undergoing TLE are low, the long-term mortality remains high with 10-year survival reported close to 50% after TLE. This is likely demonstrative of the increased burden of comorbidities with aging. There are guidelines provided by various professional societies, including the Heart Rhythm Society, regarding indications for lead extraction and management of these patients. In this paper, we will review the indications for CIED extraction, procedural considerations, and management of these patients based upon the latest guidelines.
Collapse
Affiliation(s)
- Sumit Khurana
- From the Department of Internal medicine, MedStar Union Memorial hospital, Baltimore, MD
| | - Subrat Das
- Department of Cardiology, New York Medical College, Westchester Medical Center, Valhalla, NY
| | - William H Frishman
- Department of Medicine, Westchester Medical Center and New York Medical College, NY
| | - Wilbert S Aronow
- Department of Cardiology, New York Medical College, Westchester Medical Center, Valhalla, NY
| | - Daniel Frenkel
- Department of Cardiology, New York Medical College, Westchester Medical Center, Valhalla, NY
| |
Collapse
|
2
|
Kamani Y, Peigh G, Verma N, Wasserlauf J. Cardiac Implantable Electronic Devices in Ischemic Cardiomyopathy. Heart Fail Clin 2025; 21:309-326. [PMID: 40107807 DOI: 10.1016/j.hfc.2024.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/22/2025]
Abstract
This review discusses the range of device therapy for ischemic cardiomyopathy (ICM). This article will review the primary data supporting guideline indications for cardiac implantable electronic devices in patients with ICM, with a focus on primary/secondary prevention transvenous implantable cardioverter defibrillators (ICDs), cardiac resynchronization therapy, and subcutaneous/extravascular ICDs. In addition, this review discusses emerging device therapy for ICM including left bundle area pacing/defibrillation, cardiac contractility modulation and baroflex activation therapy. Device therapy for ICM continues to evolve to incorporate diverse modalities across the spectrum from prevention of sudden cardiac death to modifying cardiac remodeling and recovery.
Collapse
Affiliation(s)
- Yash Kamani
- Division of Cardiology, Northwestern University, Feinberg School of Medicine, Arthur J. Rubloff Building, 420 East Superior Street, Chicago, IL 60611, USA
| | - Graham Peigh
- Division of Cardiac Electrophysiology, Northwestern Memorial Hospital, 251 East Huron Street Suite 8-300, Chicago, IL 60611, USA
| | - Nishant Verma
- Division of Cardiac Electrophysiology, Northwestern Memorial Hospital, 251 East Huron Street Suite 8-300, Chicago, IL 60611, USA
| | - Jeremiah Wasserlauf
- Division of Cardiology, Endeavor Health/University of Chicago Pritzker School of Medicine, 2650 Ridge Avenue, Evanston, IL 60201, USA.
| |
Collapse
|
3
|
Zagkli F, Chiladakis J. A hazardous collateral pathway following asymptomatic lead-related venous occlusion? Clin Case Rep 2024; 12:e9190. [PMID: 39055083 PMCID: PMC11272394 DOI: 10.1002/ccr3.9190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 06/14/2024] [Accepted: 07/03/2024] [Indexed: 07/27/2024] Open
Abstract
Routine venography should be performed before the device upgrade. Clinicians should not be unconcerned because of the lack of symptoms following lead-related venous occlusion. Knowledge of collateral anatomy is essential for future interventional plans. The venous pathway's return to the right atrium may entail risks to patient outcomes.
Collapse
Affiliation(s)
- Fani Zagkli
- Cardiology DepartmentUniversity Hospital of PatraPatrasGreece
| | - John Chiladakis
- Cardiology DepartmentUniversity Hospital of PatraPatrasGreece
| |
Collapse
|
4
|
Igbinomwanhia E, Jiwani S, Karim S, Pimentel R. Case Series and Review of Literature for Superior Vena Cava Injury During Laser Lead Extraction. Card Electrophysiol Clin 2024; 16:117-124. [PMID: 38749629 DOI: 10.1016/j.ccep.2023.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2024]
Abstract
Transvenous laser lead extraction poses a risk of major complications (0.19%-1.8%), notably injury to the superior vena cava (SVC) in 0.19% to 0.96% of cases. Various factors contribute to SVC injury, which can be categorized as patient-related (such as female gender, low body mass index, diabetes, renal problems, anemia, and reduced ejection fraction), device-related (including the number, dwell time, and type of leads), or procedural-related (such as reason for extraction, venous obstructions, and bilateral lead placements).
Collapse
Affiliation(s)
- Efehi Igbinomwanhia
- Heart and Vascular Institute, MetroHealth Medical Center/Case Western Reserve University, 2500 Metrohealth Drive, Cleveland, OH 44109, USA.
| | - Sania Jiwani
- Department of Cardiovascular Medicine, University of Kansas Medical Center, 3901 Rainbow Boulevard, Mailstop 4023, Kansas City, KS 66160, USA
| | - Saima Karim
- Heart and Vascular Institute, MetroHealth Medical Center/Case Western Reserve University, 2500 Metrohealth Drive, Cleveland, OH 44109, USA
| | - Rhea Pimentel
- Department of Cardiovascular Medicine, University of Kansas Medical Center, 3901 Rainbow Boulevard, Mailstop 4023, Kansas City, KS 66160, USA
| |
Collapse
|
5
|
Czajkowski M, Polewczyk A, Jacheć W, Kosior J, Nowosielecka D, Tułecki Ł, Stefańczyk P, Kutarski A. Multilevel Venous Obstruction in Patients with Cardiac Implantable Electronic Devices. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:336. [PMID: 38399623 PMCID: PMC10890105 DOI: 10.3390/medicina60020336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 01/28/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024]
Abstract
Background and Objectives: The nature of multilevel lead-related venous stenosis/occlusion (MLVSO) and its influence on transvenous lead extraction (TLE) as well as long-term survival remains poorly understood. Materials and Methods: A total of 3002 venograms obtained before a TLE were analyzed to identify the risk factors for MLVSO, as well as the procedure effectiveness and long-term survival. Results: An older patient age at the first system implantation (OR = 1.015; p < 0.001), the number of leads in the heart (OR = 1.556; p < 0.001), the placement of the coronary sinus (CS) lead (OR = 1.270; p = 0.027), leads on both sides of the chest (OR = 7.203; p < 0.001), and a previous device upgrade or downgrade with lead abandonment (OR = 2.298; p < 0.001) were the strongest predictors of MLVSO. Conclusions: The presence of MLVSO predisposes patients with cardiac implantable electronic devices (CIED) to the development of infectious complications. Patients with multiple narrowed veins are likely to undergo longer and more complex procedures with complications, and the rates of clinical and procedural success are lower in this group. Long-term survival after a TLE is similar in patients with MLVSO and those without venous obstruction. MLVSO probably better depicts the severity of global venous obstruction than the degree of vein narrowing at only one point.
Collapse
Affiliation(s)
- Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, 20-059 Lublin, Poland;
| | - Anna Polewczyk
- Institute of Medical Sciences, Jan Kochanowski University, 25-317 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-800 Zabrze, Poland;
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialist Hospital of Radom, 26-617 Radom, Poland;
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (D.N.); (P.S.)
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland;
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (D.N.); (P.S.)
| | - Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland;
| |
Collapse
|
6
|
Czajkowski M, Polewczyk A, Jacheć W, Nowosielecka D, Tułecki Ł, Stefańczyk P, Kutarski A. Pacemaker leads as a potential source of problems in patients who might need a central venous access port. Cardiovasc Diagn Ther 2023; 13:1068-1079. [PMID: 38162103 PMCID: PMC10753236 DOI: 10.21037/cdt-23-104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 08/07/2023] [Indexed: 01/03/2024]
Abstract
Background Lead-dependent venous occlusion may impede the insertion of a central venous access device (CVAD). The aim of this retrospective, cohort study was to assess the chance of implantation of CVAD in patients with cardiac implantable electronic devices (CIEDs). Methods We reviewed and analyzed 3,075 venograms of patients with CIEDs undergoing transvenous lead extraction (TLE) between June 2008 and July 2021. Relationship between venous patency and the chance of CVAD placement was estimated. Results In 2,318 (75.38%) patients, venography showed no potential obstacles to venous port implantation on the ipsilateral side. In patients with leads on the left side, significant narrowing more often affected the subclavian vein than the brachiocephalic vein [1,595 (55.29%) vs. 830 (28.63%), respectively] or the superior vena cava (SVC) [21 (0.73%) cases]. Furthermore, the subclavian and brachiocephalic veins on the opposite side were also narrowed [35 (2.35%) and 27 (1.24%), respectively]. The chances of port insertion were assessed as easy on CIED side or opposite side in 2,318 (75.38%) and 2,291 (97.91%) patients, respectively), as difficult insertion/questionable performance in 246 (8.00%) and 22 (0.94% patients) and doubtful or impossible insertion/questionable performance in 511 (16.62%)/27 (1.15%) patients with CIED. Conclusions (I) Varying degrees of lead-dependent venous obstruction (LDVO) is a frequent finding in patients with CIEDs; (II) the major thoracic veins on the opposite side of the chest may also be significantly narrowed; (III) venography should be considered before attempted CVAD insertion in patients with long lead dwell times or in patients after CIED removal, including planned contralateral port placement.
Collapse
Affiliation(s)
- Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, Lublin, Poland
| | - Anna Polewczyk
- Department of Physiology, Pathophysiology and Clinical Immunology, Institute of Medical Sciences, Jan Kochanowski University, Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Cardiology Center, Kielce, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Science in Zabrze, Medical University of Silesia in Katowice, Zabrze, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, Lublin, Poland
| |
Collapse
|
7
|
Kabutoya T. Superior vena cava obstruction and cardiovascular implantable electronic devices-a new era of leadless devices. MEDIASTINUM (HONG KONG, CHINA) 2023; 8:1. [PMID: 38322191 PMCID: PMC10839517 DOI: 10.21037/med-23-33] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 11/07/2023] [Indexed: 02/08/2024]
Abstract
Cardiovascular implantable electronic devices (CIEDs) such as pacemakers and implantable cardioverter defibrillators require the placement of a transvenous lead through the superior vena cava (SVC), which can be difficult if there is stenosis or obstruction of the SVC. Moreover, SVC syndrome may occur after the lead is inserted even if the SVC was intact before the implantation. Therefore, there is need of an appropriate strategy for handling stenosis or obstruction of SVC during lead placement. In addition, advances are being made in CIEDs that do not require transvenous leads, and thus CIEDs without a transvenous lead should be considered depending on the indications and urgency of the particular case. This manuscript is divided into (I) device therapy for patients with SVC obstruction and (II) therapeutic strategy for SVC obstruction after lead implantation. In patients with SVC syndrome, treatment of the SVC occlusion should be based on the individual pathophysiology, and depending on the indications and urgency of the case, treatment with CIEDs that do not require transvenous leads should be considered. Further data must be accumulated to clarify the long-term prognosis of device implantation after treatment of SVC occlusion. In addition, transvenous lead extraction is now widely used for device-related SVC obstruction, and this procedure also merits further accumulation of data.
Collapse
|
8
|
Abdelazeem A, Ahmed A, Curnis A, Arabia G, Cerini M, Aboelhassan M, Salghetti F, Milidoni A, Nawar M, Magdy G. Transvenous lead extraction, factors affecting procedural difficulty. Acta Cardiol 2023; 78:992-999. [PMID: 37318077 DOI: 10.1080/00015385.2023.2222986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 05/19/2023] [Accepted: 05/31/2023] [Indexed: 06/16/2023]
Abstract
BACKGROUND A complex transvenous lead extraction (TLE) procedure could be associated with lower success and higher complication rates in inexperienced hands. In this study, we aim to assess the factors that determine procedural difficulty in TLE. METHODS We retrospectively studied 200 consecutive patients undergoing TLE in a single referral centre from June 2020 to December 2021. Lead extraction difficulty was assessed by the success of simple manual traction with or without a locking stylet, the need for advanced extraction tools and the number of tools required to extract the lead. Logistic and linear regression analyses were used to determine the factors independently affecting these 3 parameters. RESULTS 363 leads were extracted from 200 patients (79% males, mean age 66.85 years). The indication for TLE was device-related infection in 51.5%. Multivariate analysis revealed the lead indwelling time to be the only factor affecting the 3 parameters of difficulty. Passive fixation leads and dual coil leads increased procedural difficulty by affecting 2 parameters each. Factors that affected one parameter included infected leads, coronary sinus leads, older age of the patient and a history of valvular heart disease, all associated with a simpler procedure. Right ventricular leads were associated with a more complex one. CONCLUSION The most important factor that increased TLE procedural difficulty was a longer lead indwelling time, followed by passive fixation and dual-coil leads. Other contributing factors were the presence of infection, coronary sinus leads, older patients, a history of valvular heart disease and right ventricular leads.
Collapse
Affiliation(s)
- Ahmed Abdelazeem
- Cardiology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt
| | - Ashraf Ahmed
- Cardiology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt
| | - Antonio Curnis
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Gianmarco Arabia
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Manuel Cerini
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Mohamed Aboelhassan
- Department of Cardiovascular Medicine, Assiut University Heart Hospital, Assiut University, Assiut, Egypt
| | - Francesca Salghetti
- Cardiology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt
| | | | - Mostafa Nawar
- Cardiology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt
| | - Gehan Magdy
- Cardiology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt
| |
Collapse
|
9
|
Gutiérrez Carretero E, Ortiz Carrellán A, Valverde Pérez I, Rodríguez Mora F, Kambiz R, de Alarcón González A. Extracción percutánea de dispositivos de estimulación cardiaca. Uso de las técnicas diagnósticas de imagen para un abordaje seguro. CIRUGIA CARDIOVASCULAR 2023. [DOI: 10.1016/j.circv.2022.12.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
|
10
|
Czajkowski M, Polewczyk A, Jacheć W, Nowosielecka D, Tułecki Ł, Stefańczyk P, Kutarski A. How does a CIED presence influence chances and safety of haemodialysis access? Conclusions from over 3000 thoracic venografies. Clin Physiol Funct Imaging 2023; 43:47-57. [PMID: 36251514 PMCID: PMC10092861 DOI: 10.1111/cpf.12792] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Revised: 07/20/2022] [Accepted: 10/10/2022] [Indexed: 12/13/2022]
Abstract
Patients requiring temporal or permanent catheter or arterio-venous fistula (AVF) for haemodialysis may be in challenging situation, if they are cardiovascular implantable electronic devices (CIED) carriers. MATERIALS AND METHODS The authors analysed preoperative venogrphies of 3100 patients referred for transvenous lead extraction for a possible chance of safe haemodialysis catheter (HC) implantation or proper AVF function. RESULTS A chance of safe catheter implantation parallel to existing leads reaches 68.8% ipsilaterally to CIED. Contraindications for implantation have been found in less than 2% of cases contralaterally. Ipsilaterally proper AVF function chance has been found in 50.3% of the cases and almost 98% contralaterally. A bilateral chest electrodes location require the special attention. Abandoned lead, lead burden, bilateral leads, additional lead implantation or abandonment, and implant duration may have a significant influence on HC insertion or proper function of arteriovenous fistula. CONCLUSION (1) Obstruction of prominent thoracic veins is a frequent finding in CIED carriers and may impede or disable implantation haemodialysis accesses. (2) Implantation of temporary or permanent HC may be questionable ipsilaterally to the CIED in 31.2% and contralaterally in 2.0% of patients. Proper function of AVF is uncertain in 49.7% ipsilaterally and 2.1% contralaterally to CIED. (3) Pacing history and leads dwell time influence chances of success haemodialysis access even on the free-from CIED chest side. (4) Proper venous flow evaluation seems to be valuable in CIED carriers before an attempt of haemodialysis access formation, even contralaterally.
Collapse
Affiliation(s)
- Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, Lublin, Poland
| | - Anna Polewczyk
- Department of Medicine and Health Sciences, Jan Kochanowski University, Kielce, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Silesian Medical University , Zabrze, Poland
| | - Dorota Nowosielecka
- Department of Cardiology Surgery, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Paweł Stefańczyk
- Department of Cardiology Surgery, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, Lublin, Poland
| |
Collapse
|
11
|
Boarescu PM, Popa ID, Trifan CA, Roşian AN, Roşian ŞH. Practical Approaches to Transvenous Lead Extraction Procedures-Clinical Case Series. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:379. [PMID: 36612704 PMCID: PMC9819065 DOI: 10.3390/ijerph20010379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 12/14/2022] [Accepted: 12/22/2022] [Indexed: 06/17/2023]
Abstract
Transvenous lead extraction (TLE) is regarded as the first-line strategy for the management of complications associated with cardiac implantable electronic devices (CIEDs), when lead removal is mandatory. The decision to perform a lead extraction should take into consideration not only the strength of the clinical indication for the procedure but also many other factors such as risks versus benefits, extractor and team experience, and even patient preference. TLE is a procedure with a possible high risk of complications. In this paper, we present three clinical cases of patients who presented different indications of TLE and explain how the procedures were successfully performed. In the first clinical case, TLE was necessary because of device extravasation and suspicion of CIED pocket infection. In the second clinical case, TLE was necessary because occlusion of the left subclavian vein was found when an upgrade to cardiac resynchronization therapy was performed. In the last clinical case, TLE was necessary in order to remove magnetic resonance (MR) non-conditional leads, so the patient could undergo an MRI examination for the management of a brain tumor.
Collapse
Affiliation(s)
- Paul-Mihai Boarescu
- Department of Pharmacology, Toxicology and Clinical Pharmacology, Iuliu Haţieganu University of Medicine and Pharmacy Cluj-Napoca, Gheorghe Marinescu Street, No. 23, 400337 Cluj-Napoca, Romania
- “Niculae Stăncioiu” Heart Institute Cluj-Napoca, Calea Moților Street, No. 19-21, 400001 Cluj-Napoca, Romania
| | - Iulia Diana Popa
- “Niculae Stăncioiu” Heart Institute Cluj-Napoca, Calea Moților Street, No. 19-21, 400001 Cluj-Napoca, Romania
| | - Cătălin Aurelian Trifan
- “Niculae Stăncioiu” Heart Institute Cluj-Napoca, Calea Moților Street, No. 19-21, 400001 Cluj-Napoca, Romania
- Department of Cardiovascular Surgery, “Iuliu Haţieganu” University of Medicine and Pharmacy Cluj-Napoca, 19-21 Calea Moților Street, 400001 Cluj-Napoca, Romania
| | - Adela Nicoleta Roşian
- “Niculae Stăncioiu” Heart Institute Cluj-Napoca, Calea Moților Street, No. 19-21, 400001 Cluj-Napoca, Romania
| | - Ştefan Horia Roşian
- “Niculae Stăncioiu” Heart Institute Cluj-Napoca, Calea Moților Street, No. 19-21, 400001 Cluj-Napoca, Romania
- Department of Cardiology—Heart Institute, “Iuliu Haţieganu” University of Medicine and Pharmacy Cluj-Napoca, 19-21 Calea Moților Street, 400001 Cluj-Napoca, Romania
| |
Collapse
|
12
|
Stefańczyk P, Nowosielecka D, Polewczyk A, Jacheć W, Głowniak A, Kosior J, Kutarski A. Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:291. [PMID: 36612613 PMCID: PMC9819767 DOI: 10.3390/ijerph20010291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/21/2022] [Accepted: 12/22/2022] [Indexed: 06/17/2023]
Abstract
BACKGROUND Upgrading from pacemakers to ICDs and CRTs is a difficult procedure, and often, transvenous lead extraction (TLE) is necessary for venous access. TLE is considered riskier in patients with multiple diseases. We aimed to assess the complexity, risk, and outcome of TLE among CRT and ICD candidates. METHODS We analyzed clinical data from 2408 patients undergoing TLE between 2006 and 2021. There were 138 patients upgraded to CRT-D, 33 patients upgraded to CRT-P and 89 individuals upgraded to ICD versus 2148 patients undergoing TLE for other non-infectious indications. RESULTS The need for an upgrade was the leading indication for TLE in only 36-66% of patients. In 42.0-57.6% of patients, the upgrade procedure could be successfully done only after reestablishing access to the occluded vein. All leads were extracted in 68.1-76.4% of patients, functional leads were retained in 20.2-31.9%, non-functional leads were left in place in 0.0-1.1%, and non-functional superfluous leads were extracted in 3.6-8.4%. The long-term survival rate of patients in the CRT-upgrade group was lower (63.8%) than in the non-upgrade group (75.2%). CONCLUSIONS Upgrading a patient from an existing pacemaker to an ICD/CRT is feasible in 100% of cases, provided that TLE is performed for venous access. Major complications of TLE at the time of device upgrade are rare and, if present do not result in death.
Collapse
Affiliation(s)
- Paweł Stefańczyk
- Department of Cardiology, Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiac Surgery, Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Anna Polewczyk
- Department of Physiology, Pathophysiology and Clinical Immunology, Institute of Medical Sciences, Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Cardiology Center, 25-736 Kielce, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Silesian Medical University in Katowice, 41-800 Zabrze, Poland
| | - Andrzej Głowniak
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialist Hospital, 26-617 Radom, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| |
Collapse
|
13
|
Kutarski A, Jacheć W, Nowosielecka D, Czajkowski M, Tułecki Ł, Polewczyk A. Repeat Transvenous Lead Extraction-Predictors, Effectiveness, Complications and Long-Term Prognostic Significance. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:15602. [PMID: 36497674 PMCID: PMC9740863 DOI: 10.3390/ijerph192315602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 11/19/2022] [Accepted: 11/22/2022] [Indexed: 06/17/2023]
Abstract
BACKGROUND Data regarding repeat transvenous lead extraction (TLE) are scarce. The aim of study was to explore the frequency of repeat TLE, its safety, predisposing factors, as well as effectiveness of repeat procedures. METHODS Retrospective analysis of a large single-center database of 3654 TLEs. RESULTS Repeat TLE was a rare occurrence (193, i.e., 5,28% among 3654 TLEs). Subsequent re-extractions occurred in 12.21% of the patients. Lead failure was the most common cause of re-extraction (51.16%). Cox regression analysis showed that patients who were older at first implantation [HR = 0.987; p = 0.003], had infection-related TLE [HR = 0.392; p < 0.001] and complete procedural success [HR = 0.544; p = 0.034] were less likely to undergo repeat TLE. Functional leads left in place for continuous use [HR = 1.405; p = 0.012] or superfluous leads left in place (abandoned) [HR = 2.370; p = 0.011] were associated with an increased risk of undergoing a repeat procedure. Overall mortality in patients with repeat TLE and subsequent re-extraction in the entire FU period was similar to that in patients without a history of re-extraction [HR = 0.949; p = 0.480]. CONCLUSIONS Repeat TLE was a rare occurrence (5.28%) among TLEs. Left of both active and nonactive leads during TLE increased the risk of re-extraction. Re-extraction has no effect on the long-term mortality.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 41-800 Katowice, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Marek Czajkowski
- Department of Cardiac Surgery, Medical University, 20-059 Lublin, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Anna Polewczyk
- Institute of Medical Sciences, Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| |
Collapse
|
14
|
Czajkowski M, Jacheć W, Polewczyk A, Kosior J, Nowosielecka D, Tułecki Ł, Stefańczyk P, Kutarski A. Severity and Extent of Lead-Related Venous Obstruction in More Than 3000 Patients Undergoing Transvenous Lead Extraction. Vasc Health Risk Manag 2022; 18:629-642. [PMID: 36003848 PMCID: PMC9393197 DOI: 10.2147/vhrm.s369342] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Accepted: 07/07/2022] [Indexed: 12/02/2022] Open
Abstract
Background Lead-related venous stenosis/obstruction (LRVSO) may be a major challenge in patients with cardiac implantable electronic devices (CIED) when device upgrade, insertion of central lines, or creation of an arteriovenous fistula for hemodialysis is indicated. The aim of this study was to evaluate the extent and severity of LRVSO. Methods We performed a retrospective analysis of 3002 venograms from patients awaiting transvenous lead extraction (TLE) to assess the occurrence, severity, and extent of LRVSO. Results Mild LRVSO occurred in 19.9%, moderate in 20.7%, severe in 19.9% and total venous occlusion in 22.5% of the patients. Moderate/severe stenosis or total occlusion of the subclavian and brachiocephalic veins was found in 38.2% and 22.5% of the patients, respectively. LRSVO was not detected in 16.9% of the patients. Moderate and severe superior vena cava (SVC) obstruction and total SVC occlusion were rare (0.4%, 0.3%, and 0.3%, respectively). Lead insertion on the left side of the chest contributed to an increased risk of LRVSO compared to right-sided implantation. Major thoracic veins on the opposite side may be narrowed in varying degrees. Conclusion A total of 60% of the patients with pacemaker or high-voltage leads have an advanced form of LRVSO. Any attempt to insert new pacing leads, central lines, venous ports, or catheters for hemodialysis, or to create dialysis fistula on the same side as the existing lead should be preceded by venography. Furthermore, venography may provide useful information, if it is planned to implant the lead or the catheter on the opposite side of the chest.
Collapse
Affiliation(s)
- Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, Lublin, Poland
| | - Wojciech Jacheć
- Department of Cardiology, Zabrze, Faculty of Medical Science in Zabrze, Medical University of Silesia in Katowice, Zabrze, Poland
| | - Anna Polewczyk
- Department of Physiology, Pathophysiology and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, Kielce, Poland.,Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, Kielce, Poland
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialistic Hospital of Radom, Radom, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, Lublin, Poland
| |
Collapse
|
15
|
Callahan TD. Looking for Lead Adhesions While Planning for Transvenous Lead Extraction. J Cardiovasc Electrophysiol 2022; 33:1041-1044. [PMID: 35245950 DOI: 10.1111/jce.15436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 02/23/2022] [Indexed: 11/26/2022]
Abstract
The first implantable pacemaker was placed in the 1958, ushering in a new frontier of cardiovascular medicine. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Thomas D Callahan
- Director, Inpatient Electrophysiology Service, Associate Program Director, Cardiovascular Medicine Fellowship.,Cleveland Clinic, Clinical Assistant Professor of Medicine, Cleveland Clinic Lerner College of Medicine, Cleveland, Ohio
| |
Collapse
|
16
|
Domenichini G, Le Bloa M, Carroz P, Graf D, Herrera-Siklody C, Teres C, Porretta AP, Pascale P, Pruvot E. New Insights in Central Venous Disorders. The Role of Transvenous Lead Extractions. Front Cardiovasc Med 2022; 9:783576. [PMID: 35282352 PMCID: PMC8904723 DOI: 10.3389/fcvm.2022.783576] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Accepted: 01/24/2022] [Indexed: 11/13/2022] Open
Abstract
Over the last decades, the implementation of new technology in cardiac pacemakers and defibrillators as well as the increasing life expectancy have been associated with a higher incidence of transvenous lead complications over time. Variable degrees of venous stenosis at the level of the subclavian vein, the innominate trunk and the superior vena cava are reported in up to 50% of implanted patients. Importantly, the number of implanted leads seems to be the main risk factor for such complications. Extraction of abandoned or dysfunctional leads is a potential solution to overcome venous stenosis in case of device upgrades requiring additional leads, but also, in addition to venous angioplasty and stenting, to reduce symptoms related to the venous stenosis itself, i.e., the superior vena cava syndrome. This review explores the role of transvenous lead extraction procedures as therapeutical option in case of central venous disorders related to transvenous cardiac leads. We also describe the different extraction techniques available and other clinical indications for lead extractions such as lead infections. Finally, we discuss the alternative therapeutic options for cardiac stimulation or defibrillation in case of chronic venous occlusions that preclude the implant of conventional transvenous cardiac devices.
Collapse
Affiliation(s)
- Giulia Domenichini
- Cardiology Service, University Hospital of Lausanne, Lausanne, Switzerland
| | | | | | | | | | | | | | | | | |
Collapse
|