1
|
Kobo O, Levi Y, Abu-Fanne R, Von Birgelen C, Guédès A, Aminian A, Laanmets P, Dewilde W, Witkowski A, Monsegu J, Romo Iniguez A, Halabi M, Mamas MA, Roguin A. Impact of the number of modifiable risk factors on clinical outcomes after percutaneous coronary intervention: An analysis from the e-Ultimaster registry. IJC HEART & VASCULATURE 2024; 51:101370. [PMID: 38628296 PMCID: PMC11018637 DOI: 10.1016/j.ijcha.2024.101370] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 02/04/2024] [Accepted: 02/19/2024] [Indexed: 04/19/2024]
Abstract
Aims A substantial proportion of the patients undergoing percutaneous coronary intervention (PCI) have none of the of standard modifiable cardiovascular risk factors (SMuRFs): hypertension, diabetes, hypercholesterolaemia and smoking. The aim of this analysis was to compare clinical outcomes after PCI according to the number of SMuRFs. Methods Patients with an indication for a PCI were stratified based upon the number of SMuRFs: 0, 1, 2 or 3-4. The primary outcome was target lesion failure (TLF), a composite of cardiac death, target vessel-related myocardial infarction or clinically driven target lesion revascularization at 1-year. Inverse weighted propensity score (IWPS) adjustment was performed to adjust for differences in baseline characteristics. Results The prevalence of SMuRFs was: 0 SMuRF 16.4 %; 1 SMuRF 27.8 %; 2 SMuRFs 34.7 % and 3-4 SMuRFs 21.1 %. Patients without SMuRFs were younger, more likely to be male and had less complex coronary artery disease. The incidence of TLF increased with the number of SMuRFs: 2.65 %, 2.75 %, 3.23 %, and 4.24 %, Ptrend < 0.001. The relative risk (RR) for a TLF was 60 % higher (95 % confidence interval 1.32-1.93, p < 0.01) for patients with 3-4 SMuRFs compared to patients without SMuRFs. The trend remained (Ptrend < 0.01) after IWPS with TLF rates of 2.88 %, 2.64 %, 2.88 % and 3.65 %. The RR for a TLF was 27 % higher (95 % CI 1.05-1.53, p < 0.01). Conclusion The incidence of clinical events at 1-year increased with the number of SMuRFs. While patients without SMuRFs have a relatively favourable risk profile, more research is needed to optimize therapeutic management in the majority of patients.
Collapse
Affiliation(s)
- Ofer Kobo
- Hillel Yaffe Medical Center, Technion-Faculty of Medicine, Hadera, Israel
| | - Yaniv Levi
- Hillel Yaffe Medical Center, Technion-Faculty of Medicine, Hadera, Israel
| | - Rami Abu-Fanne
- Hillel Yaffe Medical Center, Technion-Faculty of Medicine, Hadera, Israel
| | - Clemens Von Birgelen
- Thoraxcentrum Twente, Medisch Spectrum Twente, and Department Health Technology and Services Research, University of Twente, Enschede, The Netherlands
| | - Antoine Guédès
- CHU UCL Namur, Site de Mont Godinne, Université catholique de Louvain, Belgium
| | - Adel Aminian
- Centre Hospitalier Universitaire de Charleroi, Charleroi, Belgium
| | - Peep Laanmets
- North Estonia Medical Center Foundation, Tallinn, Estonia
| | | | | | - Jacques Monsegu
- Institut Cardio-Vasculaire, Groupe Hospitalier Mutualiste, Grenoble, France
| | | | | | - Mamas A. Mamas
- Keele Cardiovascular Research Group, Centre for Prognosis Research, Institutes of Applied Clinical Science and Primary Care and Health Sciences, Keele University, Keele, Newcastle, United Kingdom
| | - Ariel Roguin
- Hillel Yaffe Medical Center, Technion-Faculty of Medicine, Hadera, Israel
| |
Collapse
|
2
|
Molnár AÁ, Pásztor DT, Tarcza Z, Merkely B. Cells in Atherosclerosis: Focus on Cellular Senescence from Basic Science to Clinical Practice. Int J Mol Sci 2023; 24:17129. [PMID: 38138958 PMCID: PMC10743093 DOI: 10.3390/ijms242417129] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 11/30/2023] [Accepted: 12/03/2023] [Indexed: 12/24/2023] Open
Abstract
Aging is a major risk factor of atherosclerosis through different complex pathways including replicative cellular senescence and age-related clonal hematopoiesis. In addition to aging, extracellular stress factors, such as mechanical and oxidative stress, can induce cellular senescence, defined as premature cellular senescence. Senescent cells can accumulate within atherosclerotic plaques over time and contribute to plaque instability. This review summarizes the role of cellular senescence in the complex pathophysiology of atherosclerosis and highlights the most important senotherapeutics tested in cardiovascular studies targeting senescence. Continued bench-to-bedside research in cellular senescence might allow the future implementation of new effective anti-atherosclerotic preventive and treatment strategies in clinical practice.
Collapse
Affiliation(s)
- Andrea Ágnes Molnár
- Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary; (D.T.P.); (Z.T.); (B.M.)
| | | | | | | |
Collapse
|
3
|
Hashimoto S, Motozawa Y, Mano T. Selection criteria in the era of perfect competition for drug-eluting stents - a survey of interventional cardiologists in Japan: the selection-DES study. Expert Rev Med Devices 2023; 20:1235-1242. [PMID: 37904312 DOI: 10.1080/17434440.2023.2277221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Accepted: 09/27/2023] [Indexed: 11/01/2023]
Abstract
BACKGROUND More than 20 years have passed since the first company introduced drug-eluting stent (DES) in 2002, but competing companies still have improved their DESs under regulatory approval. This study aimed to investigate the criteria for interventional cardiologists performing percutaneous coronary intervention (PCI) in selecting a DES. RESEARCH DESIGN AND METHODS From 10 April 2023, to 30 April 2023, 3,422 cardiologists were requested to complete a questionnaire, of whom 126 responded to the survey. RESULTS Overall, 86.5% of the respondents used Xience cobalt-chromium everolimus-eluting stent (Xience) in > 10% of PCI procedures. For Xience, brand loyalty and calcified lesions were important independent variables for the DES selection criteria. Ultimaster sirolimus-eluting stent (Ultimaster) was not affected by the clinical data delivered by the company, whereas the respondents were shown to seek support for their activities from the Ultimaster supplier. The relationship with the company and/or sales representative and the planned surgical procedure affected the use of Coroflex ISAR NEO sirolimus-eluting polymer-free stent. CONCLUSIONS Patient background and lesion characteristics had little impact on the DES selection criteria, suggesting that DES performance has already reached its physical limitations to the extent that respondents may not value further improvements in performance or characteristics of DES.
Collapse
Affiliation(s)
- Satoru Hashimoto
- Department of Healthcare Management, TCROSS Co., Ltd, Tokyo, Japan
- Chuo University Graduate School of Strategic Management, Tokyo, Japan
| | - Yoshihiro Motozawa
- Department of Healthcare Management, TCROSS Co., Ltd, Tokyo, Japan
- Department of Internal Medicine, Sanikukai Hospital, Tokyo, Japan
| | - Toshiki Mano
- Chuo University Graduate School of Strategic Management, Tokyo, Japan
| |
Collapse
|
4
|
Gherasie FA, Valentin C, Busnatu SS. Is There an Advantage of Ultrathin-Strut Drug-Eluting Stents over Second- and Third-Generation Drug-Eluting Stents? J Pers Med 2023; 13:jpm13050753. [PMID: 37240923 DOI: 10.3390/jpm13050753] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 04/25/2023] [Accepted: 04/26/2023] [Indexed: 05/28/2023] Open
Abstract
In patients undergoing percutaneous coronary intervention, the second-generation drug-eluting stents (DES) are considered the gold standard of care for revascularization. By reducing neointimal hyperplasia, drug-eluting coronary stents decrease the need for repeat revascularizations compared with conventional coronary stents without an antiproliferative drug coating. It is important to note that early-generation DESs were associated with an increased risk of very late stent thrombosis, most likely due to delayed endothelialization or a delayed hypersensitivity reaction to the polymer. Studies have shown a lower risk of very late stent thrombosis with developing second-generation DESs with biocompatible and biodegradable polymers or without polymers altogether. In addition, research has indicated that thinner struts are associated with a reduced risk of intrastent restenosis and angiographic and clinical results. A DES with ultrathin struts (strut thickness of 70 µm) is more flexible, facilitates better tracking, and is more crossable than a conventional second-generation DES. The question is whether ultrathin eluting drug stents suit all kinds of lesions. Several authors have reported that improved coverage with less thrombus protrusion reduced the risk of distal embolization in patients with ST-elevation myocardial infarction (STEMI). Others have described that an ultrathin stent might recoil due to low radial strength. This could lead to residual stenosis and repeated revascularization of the artery. In CTO patients, the ultrathin stent failed to prove non-inferiority regarding in-segment late lumen loss and showed statistically higher rates of restenosis. Ultrathin-strut DESs with biodegradable polymers have limitations when treating calcified (or ostial) lesions and CTOs. However, they also possess certain advantages regarding deliverability (tight stenosis, tortuous lesions, high angulation, etc.), ease of use in bifurcation lesions, better endothelialization and vascular healing, and reducing stent thrombosis risk. In light of this, ultrathin-strut stents present a promising alternative to existing DESs of the second and third generation. The aims of the study are to compare ultrathin eluting stents with second- and third-generation conventional stents regarding procedural performance and outcomes based on different lesion types and specific populations.
Collapse
Affiliation(s)
| | - Chioncel Valentin
- Department of Cardiology, University of Medicine and Pharmacy "Carol Davila," 050474 Bucharest, Romania
- Emergency Clinical Hospital Dr. Bagdasar-Arseni, 050474 Bucharest, Romania
| | - Stefan-Sebastian Busnatu
- Department of Cardiology, University of Medicine and Pharmacy "Carol Davila," 050474 Bucharest, Romania
- Emergency Clinical Hospital Dr. Bagdasar-Arseni, 050474 Bucharest, Romania
| |
Collapse
|
5
|
Adhami M, Martin NK, Maguire C, Courtenay AJ, Donnelly RF, Domínguez-Robles J, Larrañeta E. Drug loaded implantable devices to treat cardiovascular disease. Expert Opin Drug Deliv 2023; 20:507-522. [PMID: 36924328 DOI: 10.1080/17425247.2023.2190580] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
INTRODUCTION It is widely acknowledged that cardiovascular diseases (CVDs) continue to be the leading cause of death globally. Furthermore, CVDs are the leading cause of diminished quality of life for patients, frequently as a result of their progressive deterioration. Medical implants that release drugs into the body are active implants that do more than just provide mechanical support; they also have a therapeutic role. Primarily, this is achieved through the controlled release of active pharmaceutical ingredients (API) at the implementation site. AREAS COVERED In this review, the authors discuss drug-eluting stents, drug-eluting vascular grafts, and drug-eluting cardiac patches with the aim of providing a broad overview of the three most common types of cardiac implant. EXPERT OPINION Drug eluting implants are an ideal alternative to traditional drug delivery because they allow for accurate drug release, local drug delivery to the target tissue, and minimise the adverse side effects associated with systemic administration. Despite the fact that there are still challenges that need to be addressed, the ever-evolving new technologies are making the fabrication of drug eluting implants a rewarding therapeutic endeavour with the possibility for even greater advances.
Collapse
Affiliation(s)
| | | | | | - Aaron J Courtenay
- School of Pharmacy and Pharmaceutical Sciences, Ulster University, UK
| | | | - Juan Domínguez-Robles
- School of Pharmacy, Queen's University Belfast, UK.,Department of Pharmacy and Pharmaceutical Technology, University of Seville, Seville, Spain
| | | |
Collapse
|
6
|
Koźlik M, Harpula J, Chuchra PJ, Nowak M, Wojakowski W, Gąsior P. Drug-Eluting Stents: Technical and Clinical Progress. Biomimetics (Basel) 2023; 8:biomimetics8010072. [PMID: 36810403 PMCID: PMC9944483 DOI: 10.3390/biomimetics8010072] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 02/02/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023] Open
Abstract
Drug-eluting stents (DES) demonstrated superior efficacy when compared to bare metal stents and plain-old balloon angioplasty and are nowadays used in almost all percutaneous revascularization procedures. The design of the stent platforms is constantly improving to maximize its efficacy and safety. Constant development of DES includes adoption of new materials used for scaffold production, new design types, improved overexpansion abilities, new polymers coating and, finally, improved antiproliferative agents. Especially nowadays, with the immense number of available DES platforms, it is crucial to understand how different aspects of stents impact the effect of their implantation, as subtle differences between various stent platforms could impact the most important issue-clinical outcomes. This review discusses the current status of coronary stents and the impact of stent material, strut design and coating techniques on cardiovascular outcomes.
Collapse
Affiliation(s)
- Maciej Koźlik
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland
- Correspondence:
| | - Jan Harpula
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland
| | - Piotr J. Chuchra
- Students’ Scientific Society, Department of Cardiology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Magdalena Nowak
- Students’ Scientific Society, Department of Cardiology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Wojciech Wojakowski
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland
| | - Paweł Gąsior
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland
| |
Collapse
|
7
|
Exarchos V, Zacharova E, Neuber S, Giampietro C, Motta SE, Hinkov H, Emmert MY, Nazari-Shafti TZ. The path to a hemocompatible cardiovascular implant: Advances and challenges of current endothelialization strategies. Front Cardiovasc Med 2022; 9:971028. [PMID: 36186971 PMCID: PMC9515323 DOI: 10.3389/fcvm.2022.971028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 08/01/2022] [Indexed: 11/13/2022] Open
Abstract
Cardiovascular (CV) implants are still associated with thrombogenicity due to insufficient hemocompatibility. Endothelialization of their luminal surface is a promising strategy to increase their hemocompatibility. In this review, we provide a collection of research studies and review articles aiming to summarize the recent efforts on surface modifications of CV implants, including stents, grafts, valves, and ventricular assist devises. We focus in particular on the implementation of micrometer or nanoscale surface modifications, physical characteristics of known biomaterials (such as wetness and stiffness), and surface morphological features (such as gratings, fibers, pores, and pits). We also review how biomechanical signals originating from the endothelial cell for surface interaction can be directed by topography engineering approaches toward the survival of the endothelium and its long-term adaptation. Finally, we summarize the regulatory and economic challenges that may prevent clinical implementation of endothelialized CV implants.
Collapse
Affiliation(s)
- Vasileios Exarchos
- Cardiosurgical Research Group, Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
- Translational Cardiovascular Regenerative Technologies Group, Berlin Institute of Health at Charité – Universitätsmedizin Berlin, BIH Center for Regenerative Therapies, Berlin, Germany
| | - Ema Zacharova
- Cardiosurgical Research Group, Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
- Translational Cardiovascular Regenerative Technologies Group, Berlin Institute of Health at Charité – Universitätsmedizin Berlin, BIH Center for Regenerative Therapies, Berlin, Germany
- Department of Life Sciences, IMC University of Applied Sciences Krems, Krems an der Donau, Austria
| | - Sebastian Neuber
- Cardiosurgical Research Group, Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
- Translational Cardiovascular Regenerative Technologies Group, Berlin Institute of Health at Charité – Universitätsmedizin Berlin, BIH Center for Regenerative Therapies, Berlin, Germany
| | - Costanza Giampietro
- Experimental Continuum Mechanics, Empa Swiss Federal Laboratories for Materials Science and Technology, Dübendorf, Switzerland
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland
| | - Sarah E. Motta
- Institute for Regenerative Medicine, University of Zurich, Zurich, Switzerland
| | - Hristian Hinkov
- Cardiosurgical Research Group, Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
- Translational Cardiovascular Regenerative Technologies Group, Berlin Institute of Health at Charité – Universitätsmedizin Berlin, BIH Center for Regenerative Therapies, Berlin, Germany
| | - Maximilian Y. Emmert
- Cardiosurgical Research Group, Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
- Translational Cardiovascular Regenerative Technologies Group, Berlin Institute of Health at Charité – Universitätsmedizin Berlin, BIH Center for Regenerative Therapies, Berlin, Germany
- Institute for Regenerative Medicine, University of Zurich, Zurich, Switzerland
- Clinic for Cardiovascular Surgery, Charité – Universitätsmedizin Berlin, Berlin, Germany
- Department of Health Sciences and Technology, ETH Zürich, Zurich, Switzerland
| | - Timo Z. Nazari-Shafti
- Cardiosurgical Research Group, Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
- Translational Cardiovascular Regenerative Technologies Group, Berlin Institute of Health at Charité – Universitätsmedizin Berlin, BIH Center for Regenerative Therapies, Berlin, Germany
- Berlin Institute of Health at Charité – Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité (Junior) (Digital) Clinician Scientist Program, Berlin, Germany
- *Correspondence: Timo Z. Nazari-Shafti,
| |
Collapse
|
8
|
Ultrathin Struts Drug-Eluting Stents: A State-of-the-Art Review. J Pers Med 2022; 12:jpm12091378. [PMID: 36143162 PMCID: PMC9503315 DOI: 10.3390/jpm12091378] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 08/21/2022] [Accepted: 08/23/2022] [Indexed: 11/17/2022] Open
Abstract
New-generation drug-eluting stents (DESs) represent the standard of care for patients undergoing percutaneous coronary intervention (PCI). Recent iterations in DES technology have led to the development of newer stent platforms with a further reduction in strut thickness. This new DES class, known as ultrathin struts DESs, has struts thinner than 70 µm. The evidence base for these devices consists of observational data, large-scale meta-analyses, and randomized trials with long-term follow-up, which have been conducted to investigate the difference between ultrathin struts DESs and conventional new-generation DESs in a variety of clinical settings and lesion subsets. Ultrathin struts DESs may further improve the efficacy and safety profile of PCI by reducing the risk of target-lesion and target-vessel failures in comparison to new-generation DESs. In this article, we reviewed device characteristics and clinical data of the Orsiro (Biotronik, Bülach, Switzerland), Coroflex ISAR (B. Braun Melsungen, Germany), BioMime (Meril Life Sciences Pvt. Ltd., Gujarat, India), MiStent (MiCell Technologies, USA), and Supraflex (Sahajanand Medical Technologies, Surat, India) sirolimus-eluting stents.
Collapse
|
9
|
Zhang Z, Zhu L, Hu W, Dai J, Ren P, Shao X, Xiong B, Zhang T, Ji Z. Polypropylene mesh combined with electrospun poly (L-lactic acid) membrane in situ releasing sirolimus and its anti-adhesion efficiency in rat hernia repair. Colloids Surf B Biointerfaces 2022; 218:112772. [PMID: 35985128 DOI: 10.1016/j.colsurfb.2022.112772] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/23/2022] [Accepted: 08/08/2022] [Indexed: 11/16/2022]
Abstract
This study developed, a novel polypropylene (PP) mesh combined with poly (L-lactic acid) (PLA) electrospun nanofibers loaded sirolimus (SRL). The PP mesh was combined with PLA/SRL (1/0, 1/0.01, 1/0.02; mass ratios) composed electrospun membrane characterized by FTIR spectroscopy, XPS and SEM, and evaluated for cytocompatibility in vitro. In an in vivo study, a total of 84 Sprague-Dawley rats were employed to evaluate the efficacy of the novel composite PP mesh anti-adhesion, mechanical properties and inflammation. As a results, the PLA/SRL membrane could compound with PP mesh stably and load SRL. Although tensile testing showed that the mechanical properties of composite mesh decreased in vivo, the integration strength between the tissue and mesh was still able to counteract intra-abdominal pressure. Compared with the native PP mesh group, the novel PP mesh group showed a lower score for abdominal adhesion and inflammation. More importantly, the novel PP mesh completely integrated with the abdominal wall and had sufficient mechanical strength to repair abdominal wall defects.
Collapse
Affiliation(s)
- Zhigang Zhang
- Department of General Surgery, Affiliated ZhongDa Hospital, Southeast University, Dingjiaqiao 87, Nanjing 210009, China; Medical School of Southeast University, Dingjiaqiao 87, Nanjing 210009, China
| | - Long Zhu
- Medical School of Southeast University, Dingjiaqiao 87, Nanjing 210009, China
| | - Wanjun Hu
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China; Department of light industry and materials science, Chengdu Textile College, Chengdu 611731, China.
| | - Jidong Dai
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Pengfei Ren
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Xiangyu Shao
- Department of General Surgery, Affiliated ZhongDa Hospital, Southeast University, Dingjiaqiao 87, Nanjing 210009, China
| | - Bo Xiong
- Department of General Surgery, Affiliated Zhong Da Hospital (Li Shui branch), Southeast University, China
| | - Tianzhu Zhang
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.
| | - Zhenling Ji
- Department of General Surgery, Affiliated ZhongDa Hospital, Southeast University, Dingjiaqiao 87, Nanjing 210009, China; Department of General Surgery, Affiliated Zhong Da Hospital (Li Shui branch), Southeast University, China.
| |
Collapse
|
10
|
Cimci M, Polad J, Mamas M, Iniguez-Romo A, Chevalier B, Abhaichand R, Aminian A, Roguin A, Maluenda G, Angioi M, Cassel G, Kuramitsu S, Jacobs L, Debrus R, Malik F, Hildick-Smith D, Laanmets P, Roffi M. Outcomes and regional differences in practice in a worldwide coronary stent registry. Heart 2022; 108:1310-1318. [PMID: 35012960 PMCID: PMC9340045 DOI: 10.1136/heartjnl-2021-320116] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Accepted: 11/08/2021] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE The primary objective was to assess the performance of a new generation thin-strut sirolimus-eluting coronary stent with abluminal biodegradable polymer in an all comer population. The secondary objective was to detail differences in contemporary percutaneous coronary intervention (PCI) practice worldwide. METHODS e-Ultimaster was an all-comer, prospective, global registry (NCT02188355) with independent event adjudication enrolling patients undergoing PCI with the study stent. The primary outcome measure was target lesion failure (TLF) at 1 year, defined as the composite of cardiac death, target vessel myocardial infarction and clinically driven target lesion revascularisation. Data were stratified according to 4 geographical regions. RESULTS A total of 37 198 patients were enrolled (Europe 69.2%, Asia 17.8%, Africa/Middle East 6.6% and South America/Mexico 6.5%) and 1-year follow-up was available for 35 389 patients (95.1%). One-year TLF occurred in 3.2% of the patients, ranging from 2% (Africa/Middle East) to 4.1% (South America/Mexico). In patients with acute coronary syndrome, potent P2Y12 inhibitors were prescribed in 48% of patients at discharge, while at 1 year 72% were on any dual antiplatelet therapy. Lipid-lowering treatment was administered in 80.9% and 75.5% of patients at discharge and 1 year, respectively. Regional differences in the profile of the treated patients as well as in PCI practice were reported. CONCLUSIONS In this investigation with worldwide representation, contemporary PCI using a new generation thin-strut sirolimus-eluting coronary stent with abluminal biodegradable polymer was associated with low 1-year TLF across clinical presentations and continents. Suboptimal adherence to current recommendations around antiplatelet and lipid lowering treatments was detected.
Collapse
Affiliation(s)
- Murat Cimci
- Division of Cardiology, University Hospitals Geneva, Geneva, Switzerland
| | - Jawed Polad
- Department of Cardiology, Jeroen Bosch Hospital, 's-Hertogenbosch, The Netherlands
| | - Mamas Mamas
- Keele Cardiovascular Research Group, Center for Prognosis Research, Keele University, Keele, UK
- Department of Cardiology, University Hospital of North Midlands, Stoke-on-Trent, UK
| | | | - Bernard Chevalier
- Ramsay Générale de Santé, Institut Cardiovasculaire Paris Sud, Massy, France
| | - Rajpal Abhaichand
- Department of Cardiology, GKNM Hospital, Coimbatore, Tamil Nadu, India
| | - Adel Aminian
- Department of Cardiology, Centre Hospitalier Universitaire de Charleroi, Charleroi, Belgium
| | - Ariel Roguin
- Departmement of Cardiology, Hillel Yaffe Medical Center, Hadera, Israel
- Faculty of Medicine, Technion Israel Institute of Technology The Ruth and Bruce Rappaport, Haifa, Israel
| | - Gabriel Maluenda
- Cardiology, Hospital Clinico San Borja Arriaran, Santiago, Chile
| | | | - Graham Cassel
- Netcare Milpark Hospital, Johannesburg, South Africa
| | | | - Lotte Jacobs
- Medical and Clinical Division, Terumo Europe NV, Leuven, Belgium
| | - Roxane Debrus
- Medical and Clinical Division, Terumo Europe NV, Leuven, Belgium
| | - Fazila Malik
- National Heart Foundation Hospital and Research Institute, Dhaka, Bangladesh
| | | | - Peep Laanmets
- North Estonia Medical Centre Foundation, Tallinn, Estonia
| | - Marco Roffi
- Division of Cardiology, University Hospitals Geneva, Geneva, Switzerland
| |
Collapse
|
11
|
Kobo O, Saada M, von Birgelen C, Tonino PAL, Íñiguez-Romo A, Fröbert O, Halabi M, Oemrawsingh RM, Polad J, IJsselmuiden AJJ, Roffi M, Aminian A, Mamas MA, Roguin A. Impact of Multisite artery disease on Clinical Outcomes After Percutaneous Coronary Intervention: An Analysis from the e-Ultimaster Registry. EUROPEAN HEART JOURNAL. QUALITY OF CARE & CLINICAL OUTCOMES 2022:qcac043. [PMID: 35876646 DOI: 10.1093/ehjqcco/qcac043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND multisite artery disease is considered a 'malignant' type of atherosclerotic disease associated with an increased cardiovascular risk, but the impact of multisite artery disease on clinical outcomes after percutaneous coronary intervention (PCI) is unknown. METHODS Patients enrolled in the large, prospective e-Ultimaster study were grouped into 1) those without known prior vascular disease; 2) those with known single-territory vascular disease 3) those with known 2-3 territories (i.e, coronary, cerebrovascular, or peripheral) vascular disease (multisite artery disease). The primary outcome was coronary target lesion failure (TLF) defined as the composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization at 1-year. Inverse propensity score weighted (IPSW) analysis was performed to address differences in baseline patient and lesion characteristics. RESULTS Of the 37,198 patients included in the study, 62.3% had no prior known vascular disease, 32.6% had single-territory vascular disease, and 5.1% multisite artery disease. Patients with known vascular disease were older and were more likely to be men and to have more co-morbidities. After IPSW, the TLF rate incrementally increased with the number of diseased vascular beds (3.16%, 4.44% and 6.42% for no, single- and multisite artery disease, p<0.01 for all comparisons). This was also true for all cause death (2.22%, 3.28% and 5.29%, p<0.01 for all comparisons) and cardiac mortality (1.26%, 1.91% and 3.62%, p≤0.01 for all comparisons). CONCLUSIONS Patients with previously known vascular disease experienced an increased risk for adverse cardiovascular events and mortality post percutaneous coronary intervention. This risk is highest among patients with multisite artery disease.Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02188355.
Collapse
Affiliation(s)
- Ofer Kobo
- Hillel Yaffe Medical Center, Technion - Faculty of Medicine, Israel
| | - Majdi Saada
- Hillel Yaffe Medical Center, Technion - Faculty of Medicine, Israel
| | | | - Pim A L Tonino
- Department of Cardiology, Catharina Hospital, Eindhoven, Netherlands
| | | | - Ole Fröbert
- Department of Cardiology, Faculty of Health, Örebro University, Örebro, Sweden
| | | | | | - Jawed Polad
- Jeroen Bosch Ziekenhuis, 's Hertogenbosch, Netherlands
| | | | - Marco Roffi
- Division of Cardiology, University Hospitals, Geneva, Switzerland
| | - Adel Aminian
- Centre Hospitalier Universitaire de Charleroi, Charleroi, Belgium
| | - Mamas A Mamas
- Keele Cardiovascular Research Group, Centre for Prognosis Research, Keele University, United Kingdom
| | - Ariel Roguin
- Hillel Yaffe Medical Center, Technion - Faculty of Medicine, Israel
| |
Collapse
|
12
|
Hassan S, Najabat Ali M, Ghafoor B. An appraisal of polymers of DES technology and their impact on drug release kinetics. INT J POLYM MATER PO 2022. [DOI: 10.1080/00914037.2022.2090941] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Sadia Hassan
- Department of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Murtaza Najabat Ali
- Department of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Bakhtawar Ghafoor
- Department of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| |
Collapse
|
13
|
Hassan S, Ali MN, Ghafoor B. Evolutionary perspective of drug eluting stents: from thick polymer to polymer free approach. J Cardiothorac Surg 2022; 17:65. [PMID: 35379273 PMCID: PMC8981810 DOI: 10.1186/s13019-022-01812-y] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 03/20/2022] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Introduction of Bare Metal Stents (BMS) was itself a revolutionary step in the history of the medical industry; however, Drug Eluting Stents (DES) maintained its superiority over BMS in every aspect from restenosis rate to late lumen loss. The reason behind the magnanimous position of the DES in the stent market is the degree of improvement with which it evolves. New and better stents come into the market every year, surpassing their predecessors by many folds. LITERATURE REVIEW This review paper discusses the journey of DES with supporting clinical trials in detail. In the first generation, there were stainless-steel stents with thicker coatings. Although they had superior results compared to BMS, there was still room for improvement. Afterward came the second-generation stents, which had superior metal platforms with thinner struts and thin coatings. The drugs were also changed from Paclitaxel and Sirolimus to Zotrolimus and Everolimus. These stents performed best; however, there was an issue of permanent coating, which remained intact over the stent surface after complete drug elution and started to cause issues in longer-term studies. Hence, an improved version of DES was introduced to these permanent coatings called the third generation of drug eluting stents, which initially utilized biodegradable polymer and ultimately moved towards polymer free drug coatings. This generation has introduced a unique amalgam of technologies to achieve its polymer free coatings; however, researchers have numerous prospects of growth in this field. This review paper highlights the major coups of stent technology evolution from BMS to DES, from thick polymeric coatings to thin coatings and from durable polymers to polymer free DES. CONCLUSION In conclusion, though the medical industry promptly accepted BMS as the best treatment option for cardiovascular diseases; however, DES has provided even better results than BMS. In DES, the first and second generation has ruled the technology for many years and are still on the shelves. Still, the issues aroused due to durable polymer shifted the attention towards biodegradable drug eluting stents, the third generation growing rapidly. But the scientific community has not restricted themselves and is investigating bioresorbable stents that completely eliminate the polymer intervention in drug eluting stent technology.
Collapse
Affiliation(s)
- Sadia Hassan
- Department of Biomedical Engineering and Sciences (BMES), School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan
| | - Murtaza Najabat Ali
- Department of Biomedical Engineering and Sciences (BMES), School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan.
| | - Bakhtawar Ghafoor
- Department of Biomedical Engineering and Sciences (BMES), School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad, Pakistan
| |
Collapse
|
14
|
Williams T, Mittal A, Karageorgiev D, Iniguez Romo A, Aminian A, Fernandez Portalese J, Kharrat E, Gómez‐Hospital JA, Firman D, Trillo Nouche R, Hildick‐Smith D. Complete revascularization optimizes patient outcomes in multivessel coronary artery disease: Data from the e-Ultimaster registry. Catheter Cardiovasc Interv 2022; 99:961-967. [PMID: 34962059 PMCID: PMC9544253 DOI: 10.1002/ccd.30042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 10/23/2021] [Accepted: 12/06/2021] [Indexed: 11/09/2022]
Abstract
OBJECTIVES The aim of this analysis was to assess the effect of the coronary revascularization strategy during index admission on clinical outcomes among patients undergoing percutaneous coronary intervention (PCI) with multivessel coronary artery disease (MVD). BACKGROUND The value of complete revascularization (CR) over incomplete revascularization (IR) in MVD patients is not fully established. METHODS Patients with MVD defined as ≥2 major epicardial vessels with ≥50% stenosis were selected from the observational all-comer e-Ultimaster registry. Patients were treated with a sirolimus-eluting thin-strut coronary stent. Completeness of revascularization was physician assessed at the index procedure or an eventually staged procedure during the index hospitalization. Outcomes measures at 1 year were target lesion failure (TLF) (composite of cardiac death, target vessel-related myocardial infarction [MI], and clinically driven target lesion revascularization [TLR]), and patient-oriented composite endpoint (POCE) (all-cause mortality, MI, or revascularization). The inverse probability of treatment weights (IPTW) methodology was used to perform a matched analysis. RESULTS The registry recruited 37,198 patients of whom 15,441 (41.5%) had MVD. CR on hospital discharge was achieved in 7413 (48.0%) patients and IR in 8028 (52.0%) patients. Mean age was 64.6 ± 11.1 versus 65.7 ± 11.0 years (p < 0.01), male gender 77.9% and 77.3% (p = 0.41) and diabetes 31.3% versus 33.4% (p = 0.01) for CR and IR, respectively. Chronic stable angina patients more commonly underwent CR (47.6% vs. 36.8%, p < 0.01). After propensity weighted analysis, 90.5% of CR patients were angina-free at 1 year compared with 87.5% of IR patients (p < 0.01). TLF (3.3% vs. 4.4%; p < 0.01), POCE (6.8% vs. 10.8%; p < .01), and all-cause mortality (2.3% vs. 3.1%; p < .01) were all lower in CR patients. CONCLUSIONS A physician-directed use of a CR strategy utilizing sirolimus-eluting thin-strut stent results in optimized clinical outcomes and less angina in an all-comer population. Our findings suggest that a CR should be aimed for.
Collapse
Affiliation(s)
| | - Aaina Mittal
- Sussex Cardiac CentreBrighton and Sussex University HospitalsUK
| | | | - Andres Iniguez Romo
- Department of Cardiology, Hospital Alvaro CunqueiroUniversity Hospital of VigoVigoSpain
| | - Adel Aminian
- Department of Cardiology, Centre Hospitalier Universitaire de Charleroi, CharleroiBelgium CHU CharleroiCharleroiBelgium
| | | | | | | | - Doni Firman
- Department of Cardiology and Vascular Medicine, Harapan Kita National Cardiovascular CenterFaculty of Medicine UniversitasWest JakartaIndonesia
| | - Ramiro Trillo Nouche
- Hospital Clínico Universitario de Santiago de CompostelaSantiago de CompostelaSpain
| | | | | |
Collapse
|
15
|
Kobo O, Saada M, Laanmets P, Karageorgiev D, Routledge H, Crowley J, Baello P, Requena JB, Spanó F, Perez L, Jimenez Mazuecos JM, Mamas MA, Roguin A. Impact of peripheral artery disease on prognosis after percutaneous coronary intervention: Outcomes from the multicenter prospective e-ULTIMASTER registry. Atherosclerosis 2022; 344:71-77. [DOI: 10.1016/j.atherosclerosis.2022.01.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/14/2021] [Accepted: 01/14/2022] [Indexed: 11/02/2022]
|
16
|
Chevalier B, Mamas M, Hovasse T, Rashid M, Gómez-Hospital J, Pan M, Witkowski A, Crowley J, Aminian A, McDonald J, Beygui F, Fernandez Portales J, Roguin A, Stankovic G. Clinical outcomes of the proximal optimisation technique (POT) in bifurcation stenting. EUROINTERVENTION 2021; 17:e910-e918. [PMID: 33970107 PMCID: PMC9724857 DOI: 10.4244/eij-d-20-01393] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND Optimal deployment of coronary stents in a bifurcation lesion remains a matter of debate. AIMS We sought to capture the daily practice of bifurcation stenting by means of a worldwide registry and to investigate how post-implantation deployment techniques influence clinical outcomes. METHODS Data from the e-ULTIMASTER registry were used to perform an analysis of 4,395 patients undergoing percutaneous coronary intervention for bifurcation lesions. Inverse probability of treatment weights (IPTW) propensity score methodology was used to adjust for any baseline differences. The primary outcome of interest was target lesion failure (TLF) at one year (follow-up rate 96.2%). RESULTS The global one-year TLF rate was low (5.1%). The proximal optimisation technique (POT) was used in 33.9% of cases and was associated with a reduction in the adjusted TLF rate (4.0% [95% confidence interval: 3.0-5.1%] vs 6.0% [5.1-6.9%], p<0.01) due to a reduction of all components of this composite endpoint, except for cardiac death. Stent thrombosis was also positively impacted (0.4% [0.04-0.7%] vs 1.3% [0.8-1.7%], p<0.01). POT benefit was uniform across subgroups. Conversely, the use of the kissing balloon technique (36.5%) did not influence the adjusted TLF rate. CONCLUSIONS Despite a low one-year failure rate in this large bifurcation stenting cohort, POT was associated with a further reduction in the event rate and a uniform benefit across subgroups, suggesting systematic use of this deployment technique regardless of the bifurcation anatomy and stenting technique.
Collapse
Affiliation(s)
- Bernard Chevalier
- ICPS, Hôpital Privé Jacques Cartier, 6 Avenue du Noyer Lambert, 91300 Massy, France
| | - Mamas Mamas
- Department of Cardiology, University Hospital of North Midlands, Stoke-on-Trent, United Kingdom,Keele Cardiovascular Research Group, Centre of Prognosis Research, Institute of Primary Care Sciences, Keele University, Stoke-on-Trent, United Kingdom
| | - Thomas Hovasse
- Ramsay Générale de Santé, ICPS, Hôpital Jacques Cartier, Massy, France
| | - Muhammad Rashid
- Department of Cardiology, University Hospital of North Midlands, Stoke-on-Trent, United Kingdom,Keele Cardiovascular Research Group, Centre of Prognosis Research, Institute of Primary Care Sciences, Keele University, Stoke-on-Trent, United Kingdom
| | - Joan Gómez-Hospital
- Heart Disease Institute, Bellvitge University Hospital (IDIBELL), University of Barcelona, Barcelona, Spain
| | - Manuel Pan
- Reina Sofia Hospital, Department of Cardiology, University of Córdoba (IMIBIC), Cordoba, Spain
| | - Adam Witkowski
- Department of Interventional Cardiology and Angiology, Institute of Cardiology, Warsaw, Poland
| | - James Crowley
- Department of Cardiology, University Hospital Galway, Galway, Ireland
| | - Adel Aminian
- Centre Hospitalier Universitaire de Charleroi, Department of Cardiology, Charleroi, Belgium
| | - John McDonald
- Department of Cardiology, Royal Blackburn Hospital, Blackburn, United Kingdom
| | - Farzin Beygui
- Department of Interventional Cardiology and Cardiology Research Units, CHU Caen, Caen, France,Keele Cardiovascular Research Group, Centre of Prognosis Research, Institute of Primary Care Sciences, Keele University, Stoke-on-Trent, United Kingdom
| | | | - Ariel Roguin
- Department of Cardiology, Hillel Yafe Medical Center, Hadera, Israel
| | - Goran Stankovic
- Department of Cardiology, Clinical Center of Serbia, University of Belgrade, Belgrade, Serbia
| |
Collapse
|
17
|
Rola P, Włodarczak A, Barycki M, Szudrowicz M, Łanocha M, Kulczycki JJ, Turkiewicz K, Woźnica K, Lesiak M, Doroszko A. Biodegradable Polymer DES (Ultimaster) vs. Magnesium Bioresorbable Scaffold (BRS Magmaris) in Diabetic Population with NSTE-ACS: A One-Year Clinical Outcome of Two Sirolimus-Eluting Stents. J Diabetes Res 2021; 2021:8636050. [PMID: 34859105 PMCID: PMC8632392 DOI: 10.1155/2021/8636050] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 10/17/2021] [Accepted: 11/05/2021] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Cardiovascular disease (CVD) with significant involvement of coronary artery disease (CAD) remains a major cause of death and disability among the diabetic population. Although percutaneous coronary intervention (PCI) continues to evolve, type 2 diabetes mellitus (T2DM) is a well-established marker of poor clinical prognosis after PCI, which is mainly attributed to the rapid progression of atherosclerosis requiring recurrent revascularizations. Hence, the use of bioresorbable materials could provide some solution to this problem. Material and Methods. The study was divided into two arms. For the first one, we qualified 169 patients with NSTE-ACS treated with PCI who received the drug-eluting stent (DES) coated with a biodegradable polymer Ultimaster (Terumo, Tokyo, Japan). The second arm was composed of 193 patients with ACS who underwent PCI with a magnesium bioresorbable scaffold Magmaris (Biotronik, Berlin, Germany). Both arms were divided into two subsequent groups: the T2DM (59 and 72) and the non-DM (110 and 121, respectively). The primary outcomes were cardiovascular death, myocardial infarction, and in-stent thrombosis. The main secondary outcomes included target lesion failure (TLF) and were recorded at a 1-year-follow-up. RESULTS There were no significant differences between the diabetic and nondiabetic populations in primary endpoints or main secondary endpoints (TLF, scaffold restenosis, death from any reason, and other cardiovascular events) either in the Ultimaster or Magmaris group. At a 1-year-follow-up, the primary endpoint in the DM t.2 population was recorded in 2.7% Ultimaster vs. 5.1% Magmaris, respectively. At the same time, the TLF occurred in the diabetic group in 4.1% Magmaris and 3.3% in the Ultimaster arm, respectively. CONCLUSION Both, Ultimaster and Magmaris revealed relative safety and efficiency at a one-year follow-up in the diabetic population in ACS settings. The observed rates of TLF were low, which combined with a lack of in-stent thrombosis suggests that both investigated devices might be an interesting therapeutic option for diabetics with ACS. Nevertheless, further large randomized clinical trials are needed to confirm fully our results.
Collapse
Affiliation(s)
- Piotr Rola
- Department of Cardiology, The Copper Health Centre (MCZ), 59-300 Lubin, Poland
- Department of Cardiology, Provincial Specialized Hospital in Legnica, 59-220 Legnica, Poland
| | - Adrian Włodarczak
- Department of Cardiology, The Copper Health Centre (MCZ), 59-300 Lubin, Poland
| | - Mateusz Barycki
- Department of Cardiology, Provincial Specialized Hospital in Legnica, 59-220 Legnica, Poland
| | - Marek Szudrowicz
- Department of Cardiology, The Copper Health Centre (MCZ), 59-300 Lubin, Poland
| | | | - Jan Jakub Kulczycki
- Department of Cardiology, The Copper Health Centre (MCZ), 59-300 Lubin, Poland
| | - Karol Turkiewicz
- Department of Cardiology, The Copper Health Centre (MCZ), 59-300 Lubin, Poland
| | - Katarzyna Woźnica
- Faculty of Mathematics and Information Science, Warsaw University of Technology, 00-662 Warsaw, Poland
| | - Maciej Lesiak
- 1st Department of Cardiology, Poznan University of Medical Sciences, 61-491 Poznan, Poland
| | - Adrian Doroszko
- Department of Internal Medicine, Hypertension and Clinical Oncology, Wroclaw Medical University, 50-556 Wroclaw, Poland
| |
Collapse
|
18
|
Vlieger S, Danzi GB, Kauer F, Oemrawsingh RM, Stojkovic S, IJsselmuiden AJ, Routledge H, Laanmets P, Roffi M, Fröbert O, Baello P, Wlodarczak A, Puentes A, Polad J, Hildick-Smith D. One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent: a propensity-matched analysis of two international all-comers registries. Coron Artery Dis 2021; 32:391-396. [PMID: 33060529 PMCID: PMC8248251 DOI: 10.1097/mca.0000000000000958] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 08/08/2020] [Indexed: 12/05/2022]
Abstract
OBJECTIVES Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice. METHODS A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events. RESULTS The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43). CONCLUSIONS These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.
Collapse
Affiliation(s)
- Selina Vlieger
- Department of Cardiology, Albert Schweitzer Ziekenhuis, Dordrecht, The Netherlands
| | - Gian B. Danzi
- Division of Cardiology, Ospedale Santa Corona, Pietra Ligure, Savona, Italy
| | - Floris Kauer
- Department of Cardiology, Albert Schweitzer Ziekenhuis, Dordrecht, The Netherlands
| | - Rohit M. Oemrawsingh
- Department of Cardiology, Albert Schweitzer Ziekenhuis, Dordrecht, The Netherlands
| | - Sinisa Stojkovic
- Department of Cardiology, Clinical Center of Serbia, Belgrade, and Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | | | | | | | - Marco Roffi
- Hôpitaux Universitaires de Genève, Geneva, Switzerland
| | - Ole Fröbert
- Department of Cardiology, Faculty of Health, Örebro University, Örebro, Sweden
| | | | | | | | - Jawed Polad
- Jeroen Bosch Hospital, ’s-Hertogenbosch, The Netherlands
| | | |
Collapse
|
19
|
Ammann KR, Hossainy SFA, Hossainy S, Slepian MJ. Hemocompatibility of polymers for use in vascular endoluminal implants. J Appl Polym Sci 2021. [DOI: 10.1002/app.51277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Kaitlyn R. Ammann
- Department of Medicine College of Medicine, University of Arizona Tucson Arizona USA
- Sarver Heart Center, Arizona Health Sciences Center University of Arizona Tucson Arizona USA
| | - Syed F. A. Hossainy
- Department of Bioengineering College of Engineering, University of California Berkeley Berkeley California USA
| | - Sahir Hossainy
- Sarver Heart Center, Arizona Health Sciences Center University of Arizona Tucson Arizona USA
| | - Marvin J. Slepian
- Department of Medicine College of Medicine, University of Arizona Tucson Arizona USA
- Sarver Heart Center, Arizona Health Sciences Center University of Arizona Tucson Arizona USA
- Department of Biomedical Engineering College of Engineering, University of Arizona Tucson Arizona USA
- Department of Materials Science and Engineering College of Engineering, University of Arizona Tucson Arizona USA
| |
Collapse
|
20
|
Ijichi T, Nakazawa G, Torii S, Nagamatsu H, Yoshikawa A, Nakamura S, Souba J, Isobe A, Hagiwara H, Ikari Y. Late neointimal volume reduction is observed following biodegradable polymer-based drug eluting stent in porcine model. IJC HEART & VASCULATURE 2021; 34:100792. [PMID: 34036146 PMCID: PMC8134975 DOI: 10.1016/j.ijcha.2021.100792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 04/23/2021] [Accepted: 04/29/2021] [Indexed: 11/05/2022]
Abstract
BACKGROUND The BP-SES has an abluminally applied biodegradable polymer that is fully resorbed after 3-4 months but may have longer-lasting effects. The aim of this study was to determine the long-term vascular response to the novel Ultimaster™ sirolimus-eluting stent (BP-SES). METHODS BP-SESs, everolimus-eluting stents (DP-EESs), and bare metal stents were implanted in 22 coronary arteries of 15 mini-swine. All animals underwent optical frequent domain imaging (OFDI) to assess neointimal volume and quality at either 1 (n = 7) or 3 (n = 8) months and at 9 (n = 15) months and were euthanized at 9 months. Stents were subsequently histologically investigated to analyze the vascular response and maturity of neointimal tissue according to cell density. RESULTS OFDI revealed greater regression in neointimal volume from 3 to 9 months with BP-SESs than with DP-EESs (-0.6 ± 0.5 mm2 vs. 0.00 ± 0.4 mm2, p = 0.07). Although there was no significant difference between BP-SESs and DP-EESs in the inflammation score (BMS, BP-SES, and DP-EES: 0.1 ± 0.1, 0.3 ± 0.4, and 0.4 ± 0.4, respectively; p < 0.0001) in histological analysis, BP-SESs showed slightly greater maturity than DP-EESs (1.8 ± 0.3, 1.7 ± 0.3, and 1.6 ± 0.3, p = 0.09). CONCLUSIONS While both BP-SESs and DP-EESs showed minimal inflammatory responses at 9 months, BP-SESs showed a trend for greater neointimal maturity and regression, which may be related to earlier completion of the vascular response.
Collapse
Affiliation(s)
- Takeshi Ijichi
- Department of Cardiology, Tokai University, School of Medicine, Kanagawa, Japan
| | - Gaku Nakazawa
- Department of Cardiology, Kindai University, Faculty of Medicine, Osaka, Japan
| | - Sho Torii
- Department of Cardiology, Tokai University, School of Medicine, Kanagawa, Japan
| | - Hirofumi Nagamatsu
- Department of Cardiology, Tokai University, School of Medicine, Kanagawa, Japan
| | - Ayako Yoshikawa
- Department of Cardiology, Tokai University, School of Medicine, Kanagawa, Japan
| | | | - Junko Souba
- TERUMO Corporation Evaluation Center, Kanagawa, Japan
| | - Atsushi Isobe
- TERUMO Corporation Evaluation Center, Kanagawa, Japan
| | | | - Yuji Ikari
- Department of Cardiology, Tokai University, School of Medicine, Kanagawa, Japan
| |
Collapse
|
21
|
Miyazaki Y, Muramatsu T, Asano T, Katagiri Y, Sotomi Y, Nakatani S, Takahashi K, Kogame N, Higuchi Y, Ishikawa M, Kyono H, Yano M, Ozaki Y, Serruys PW, Okamura T, Onuma Y. Online three-dimensional OFDI-guided versus angiography-guided PCI in bifurcation lesions: design and rationale of the randomised OPTIMUM trial. EUROINTERVENTION 2021; 16:1333-1341. [PMID: 31289018 PMCID: PMC9724853 DOI: 10.4244/eij-d-18-00902] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
AIMS The feasibility of offline optical coherence tomography (OCT) guidance in bifurcation (with either two-dimensional or three-dimensional images) and its potential benefits have been demonstrated in retrospective studies; however, these have not yet been investigated prospectively. The aim of this trial is to determine the superiority of online three-dimensional optical frequency domain imaging (3D-OFDI)-guided stenting to angiography-guided percutaneous coronary intervention (PCI) in terms of incomplete stent apposition (ISA) at the bifurcation segment. METHODS AND RESULTS The OPTIMUM trial is a randomised, superiority, multicentre clinical trial. The primary endpoint of this trial is the post-procedural percentage of malapposed struts assessed by OFDI in the main branch bifurcation region after final kissing balloon dilatation (FKBD). A total of 106 patients will be randomly allocated to either 3D-OFDI guidance or angiography guidance PCI. Bifurcation lesions will be treated with a provisional single-stent strategy using the Ultimaster sirolimus-eluting stent. Patients randomised to the 3D-OFDI guidance arm will undergo OFDI assessment in the main branch (MV) after rewiring into the jailed side branch following stent implantation, while in the angiography guidance arm re-crossing of a wire into the side branch will be performed using conventional fluoroscopic/angiographic guidance. In patients in the 3D-OFDI guidance arm, if the position of the wire is not located in the optimal cell, further attempts to redirect the wire to the optimal cell will be performed, with subsequent OFDI acquisitions to confirm the re-crossing position. The proximal optimisation technique and FKBD are mandatory in this trial. The study will provide a 90% power to show superiority of 3D-OFDI guidance PCI compared with angiography-guided PCI. CONCLUSIONS The OPTIMUM trial will be the first prospective, randomised trial to evaluate the efficacy and safety of online 3D-OFDI-guided PCI in bifurcation lesions. ClinicalTrials.gov Identifier: NCT02972489.
Collapse
Affiliation(s)
- Yosuke Miyazaki
- Thoraxcenter, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands,Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Takashi Muramatsu
- Department of Cardiology, Cardiovascular Center, Fujita Health University Hospital, Toyoake, Japan
| | - Taku Asano
- Department of Cardiology, Academic Medical Center, Amsterdam, the Netherlands
| | - Yuki Katagiri
- Department of Cardiology, Academic Medical Center, Amsterdam, the Netherlands
| | | | | | - Kuniaki Takahashi
- Department of Cardiology, Academic Medical Center, Amsterdam, the Netherlands
| | - Norihiro Kogame
- Department of Cardiology, Academic Medical Center, Amsterdam, the Netherlands
| | | | - Masato Ishikawa
- Department of Cardiology, Cardiovascular Center, Fujita Health University Hospital, Toyoake, Japan
| | - Hiroyuki Kyono
- Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan
| | - Masafumi Yano
- Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Yukio Ozaki
- Department of Cardiology, Cardiovascular Center, Fujita Health University Hospital, Toyoake, Japan
| | - Patrick W. Serruys
- International Centre for Circulatory Health, NHLI, Imperial College London, London, United Kingdom,Department of Cardiology, National University of Ireland Galway, Galway, Ireland
| | - Takayuki Okamura
- Division of Cardiology, Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Yoshinobu Onuma
- Fujita Health University Hospital, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi 470-1192, Japan
| |
Collapse
|
22
|
Migita S, Kitano D, Li Y, Koyama Y, Shimodai-Yamada S, Onishi A, Fuchimoto D, Suzuki S, Nakamura Y, Matsuyama TA, Hirota S, Sakuma M, Tsujimoto M, Hirayama A, Okumura Y, Hao H. Pathological findings after third- and second-generation everolimus-eluting stent implantations in coronary arteries from autopsy cases and an atherosclerotic porcine model. Sci Rep 2021; 11:6281. [PMID: 33737695 PMCID: PMC7973802 DOI: 10.1038/s41598-021-85740-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 02/23/2021] [Indexed: 01/10/2023] Open
Abstract
Pathological changes after third-generation drug-eluting stent implantation remain unclear. We compared the tissue responses of coronary arteries after the implantation of third-generation abluminal biodegradable-polymer everolimus-eluting stent (3rd EES) and second-generation durable-polymer EES (2nd EES) using autopsy specimens and an atherosclerotic porcine model. We compared the histology of stented coronary arteries obtained by autopsy performed 1-10 months after 3rd EES (n (number of cases) = 4, stent-implanted period of 3-7 months) and 2nd EES (n (number of cases) = 9, stent-implanted period of 1-10 months) implantations. The ratio of covered stent struts was higher with 3rd EESs than with 2nd EESs (3rd; 0.824 ± 0.032 vs. 2nd; 0.736 ± 0.022, p = 0.035). Low-density lipoprotein receptor knockout minipigs were stented with 3rd or 2nd EES in the coronary arteries and the stented regions were investigated. The fibrin deposition around the 2nd EES was more prominent. Additionally, higher density of smooth muscle cells was confirmed after the 3rd EES implantation. Pathological examination after the 3rd EES demonstrated a combination of less fibrin deposition and more rapid acquisition of well-developed neointima as compared to the 2nd EES at autopsy and the atherosclerotic porcine model.
Collapse
Affiliation(s)
- Suguru Migita
- Division of Human Pathology, Department of Pathology and Microbiology, Nihon University School of Medicine, 30-1 Oyaguchi-kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Daisuke Kitano
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Yuxin Li
- Division of Cell Regeneration and Transplantation, Department of Functional Morphology, Nihon University School of Medicine, 30-1 Oyaguchi-kamicho, Itabashi-ku, Tokyo, 173-8610, Japan.
| | - Yutaka Koyama
- Division of Human Pathology, Department of Pathology and Microbiology, Nihon University School of Medicine, 30-1 Oyaguchi-kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Sayaka Shimodai-Yamada
- Division of Human Pathology, Department of Pathology and Microbiology, Nihon University School of Medicine, 30-1 Oyaguchi-kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Akira Onishi
- Department of Animal Science and Resources, College of Bioresource Sciences, Nihon University, Kanagawa, Japan
| | - Daiichiro Fuchimoto
- Institute of Agrobiological Sciences, National Agriculture and Food Research Organization (NARO), Ibaraki, Japan
| | - Shunichi Suzuki
- Institute of Agrobiological Sciences, National Agriculture and Food Research Organization (NARO), Ibaraki, Japan
| | - Yoshiyuki Nakamura
- Swine and Poultry Research, Saitama Prefectural Agricultural Technology Research Center, Saitama, Japan
| | - Taka-Aki Matsuyama
- Department of Legal Medicine, Showa University School of Medicine, Tokyo, Japan
| | - Seiichi Hirota
- Department of Surgical Pathology, Hyogo College of Medicine, Nishinomiya, Japan
| | - Masashi Sakuma
- Department of Cardiovascular Medicine, Dokkyo Medical University School of Medicine, Tochigi, Japan
| | | | | | - Yasuo Okumura
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Hiroyuki Hao
- Division of Human Pathology, Department of Pathology and Microbiology, Nihon University School of Medicine, 30-1 Oyaguchi-kamicho, Itabashi-ku, Tokyo, 173-8610, Japan.
| |
Collapse
|
23
|
Kakizaki R, Minami Y, Katamine M, Katsura A, Muramatsu Y, Hashimoto T, Meguro K, Shimohama T, Ako J. Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes. Cardiovasc Diabetol 2020; 19:162. [PMID: 33004019 PMCID: PMC7531093 DOI: 10.1186/s12933-020-01145-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Accepted: 09/27/2020] [Indexed: 02/08/2023] Open
Abstract
Background Diabetes mellitus is a risk for increased incidence of adverse clinical events after percutaneous coronary intervention. However, the difference in the incidence of adverse clinical events according to stent type in patients with diabetes remains to be elucidated. In the present study, we aimed to compare the clinical outcomes between patients treated with the biodegradable polymer sirolimus-eluting stents (BP-SES) and the durable polymer everolimus-eluting stents (DP-EES) among patients with diabetes. Methods Among 631 lesions in 510 consecutive patients treated with either BP-SES or DP-EES, 165 lesions in 141 patients with diabetes mellitus and stable angina pectoris were identified and classified into the BP-SES group (48 lesions in 44 patients) and the DP-EES group (117 lesions in 100 patients). The incidence of adverse clinical events after stent implantation was compared between the 2 groups. Results There was no significant difference in the prevalence of conventional risk factors, lesion characteristics, and procedural characteristics between the 2 groups. During median 386 [334–472] days follow-up, the incidence of target lesion revascularization (11.4 vs. 2.0%, p = 0.003) and device-oriented clinical endpoint (13.6 vs. 6.0%, p = 0.035) in the BP-SES group was significantly greater than that in the DP-EES group. A univariate model demonstrated that the BP-SES usage was significantly associated with the higher incidence of target lesion revascularization (odds ratio, 6.686; 95% confidence interval, 1.234–36.217; p = 0.028). Conclusion BP-SES was associated with the greater incidence of TLR than the DP-EES in patients with diabetes mellitus. Further studies with larger cohorts and longer follow-up are required to confirm the present results.
Collapse
Affiliation(s)
- Ryota Kakizaki
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Yoshiyasu Minami
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan.
| | - Masahiro Katamine
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Aritomo Katsura
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Yusuke Muramatsu
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Takuya Hashimoto
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Kentaro Meguro
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Takao Shimohama
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Junya Ako
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| |
Collapse
|
24
|
Badv M, Bayat F, Weitz JI, Didar TF. Single and multi-functional coating strategies for enhancing the biocompatibility and tissue integration of blood-contacting medical implants. Biomaterials 2020; 258:120291. [PMID: 32798745 DOI: 10.1016/j.biomaterials.2020.120291] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 06/27/2020] [Accepted: 08/01/2020] [Indexed: 12/27/2022]
Abstract
Device-associated clot formation and poor tissue integration are ongoing problems with permanent and temporary implantable medical devices. These complications lead to increased rates of mortality and morbidity and impose a burden on healthcare systems. In this review, we outline the current approaches for developing single and multi-functional surface coating techniques that aim to circumvent the limitations associated with existing blood-contacting medical devices. We focus on surface coatings that possess dual hemocompatibility and biofunctionality features and discuss their advantages and shortcomings to providing a biocompatible and biodynamic interface between the medical implant and blood. Lastly, we outline the newly developed surface modification techniques that use lubricant-infused coatings and discuss their unique potential and limitations in mitigating medical device-associated complications.
Collapse
Affiliation(s)
- Maryam Badv
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada; Department of Mechanical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Fereshteh Bayat
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Jeffrey I Weitz
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada; Thrombosis & Atherosclerosis Research Institute (TaARI), Hamilton, Ontario, Canada; Department of Medicine, McMaster University, Hamilton, Ontario, Canada; Department of Biochemistry and Biomedical Sciences, McMaster University, Hamilton, Ontario, Canada
| | - Tohid F Didar
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada; Department of Mechanical Engineering, McMaster University, Hamilton, Ontario, Canada; Institute for Infectious Disease Research (IIDR), McMaster University, Hamilton, Ontario, Canada.
| |
Collapse
|
25
|
Watanabe S, Sakai C, Hori M, Kawasaki T. Insight into the Time Course of Type III Kounis Syndrome: A Case Report. J Emerg Med 2020; 59:e65-e68. [PMID: 32536494 DOI: 10.1016/j.jemermed.2020.04.054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 04/16/2020] [Accepted: 04/28/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND Kounis syndrome is a rare condition that is characterized by the coexistence of acute coronary syndrome and allergic reactions; however, its time course remains unclear. We report a case of anaphylactic shock with subsequent development of ST-segment elevation myocardial infarction. CASE REPORT A 47-year-old man with food allergies presented to the emergency department of our hospital with breathing difficulties after eating bread. He had a history of angina and underwent stent implantation 3 years earlier. On examination, he was lethargic, disoriented, and in shock. He had a rash on his face and anterior chest wall, as well as severe itching and sweating. Anaphylaxis was diagnosed and, 3 min after presentation, 0.5 mg epinephrine was injected intramuscularly into the right thigh. Electrocardiography, which was recorded 2 min after the administration of epinephrine, was normal; however, chest pain developed suddenly 18 min later. Repeat electrocardiography showed ST-segment elevations, and emergency coronary angiography revealed total occlusion of the left anterior descending coronary artery (i.e., the previous stenting site). Recanalization of the left anterior descending coronary artery was achieved after repeated thrombus aspiration with difficulty, followed by stent implantation inside of the stent under the support of intra-aortic balloon pumping. The clinical course was uneventful. He was discharged and advised to avoid eating wheat and carry an epinephrine self-injection kit for anaphylaxis. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: The present case highlights the importance of recognizing Kounis syndrome in the management of anaphylactic shock because treatment may be difficult, particularly in patients with type III Kounis syndrome.
Collapse
Affiliation(s)
- Seiru Watanabe
- Department of Cardiology, Matsushita Memorial Hospital, Osaka, Japan
| | - Chieko Sakai
- Department of Cardiology, Matsushita Memorial Hospital, Osaka, Japan
| | - Masatoshi Hori
- Department of Emergency, Matsushita Memorial Hospital, Osaka, Japan
| | - Tatsuya Kawasaki
- Department of Cardiology, Matsushita Memorial Hospital, Osaka, Japan
| |
Collapse
|
26
|
Miura T, Sonoda S, Sanuki Y, Naka Y, Okabe H, Setoyama K, Inoue K, Shimizu A, Anai R, Tsuda Y, Araki M, Otsuji Y. Comparison of post-stent irregular protrusion and subsequent neointimal characteristics between second- and third-generation drug-eluting stent implantation. J Cardiol 2020; 76:464-471. [PMID: 32636130 DOI: 10.1016/j.jjcc.2020.05.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/25/2020] [Accepted: 05/03/2020] [Indexed: 11/26/2022]
Abstract
BACKGROUND Third-generation drug-eluting-stents (3rd DES) may improve coronary arterial healing and reduce neoatherosclerosis formation. We evaluated post-stent findings and subsequent vascular healing of 3rd DES by comparing to second-generation drug-eluting-stents (2nd DES) at intermediate-term follow-up using optical coherence tomography (OCT). METHOD We evaluated 170 patients with 170 lesions who underwent DES implantation (2nd DES, n = 98; 3rd DES, n = 72) and OCT-guided follow-up examination. After propensity score (PS) matching for baseline clinical characteristics, OCT findings from 56 pairs of patients with 2nd DES and 3rd DES implants were compared. Post-stent irregular protrusion (IP) was defined as the protrusion of material with an irregular surface into the lumen between the stent struts. Neoatheroscleosis was defined as neointima contained heterogeneous pattern, rupture, lipid-laden, thin-cap fibroatheroma, or calcification. The presence of peri-strut low-intensity area (PLIA) and in-stent neointimal tissue characteristics were also analyzed at 6- to 8-month follow-up. RESULTS There were no significant differences between the incidence of post-stent IP or neoatherosclerosis formation in the 2nd DES and the 3rd DES (45% vs. 38%, p = 0.44; 30% vs. 20%, p = 0.19, respectively). However, the incidences of PLIA and layered neointimal pattern, which indicate immature neointimal healing, were significantly lower in the 3rd DES compared to the 2nd DES (41% vs. 61%, p = 0.04; 2% vs. 11%, p = 0.04, respectively). As comparing intermediate-term follow-up OCT neointimal findings in patients with IP between 2nd DES and 3rd DES, most neointima tended to have a homogeneous pattern (95% versus 76%, p = 0.06) in the 3rd DES than in the 2nd DES. CONCLUSIONS The incidence of post-stent IP and subsequent neoatherosclerosis formation at intermediate-term follow-up after stent implantation were similar between patients with 2nd DES and 3rd DES, however, vascular healing might be favorable when using 3rd DES.
Collapse
Affiliation(s)
- Toshiya Miura
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Shinjo Sonoda
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan.
| | - Yoshinori Sanuki
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Yutaro Naka
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Hiroki Okabe
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Koshi Setoyama
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Konosuke Inoue
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Akiyoshi Shimizu
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Reo Anai
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Yuki Tsuda
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Masaru Araki
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Yutaka Otsuji
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| |
Collapse
|
27
|
Gherbesi E, Danzi GB. The Ultimaster coronary stent system: 5-year worldwide experience. Future Cardiol 2020; 16:251-261. [DOI: 10.2217/fca-2019-0093] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Newer generation drug-eluting stents have significantly improved outcomes in patients undergoing percutaneous coronary intervention by reducing the risk of restenosis and stent thrombosis. In comparison with first-generation ones, contemporary drug-eluting stents have thinner struts and more biocompatible polymers, which reduce inflammation, promote endothelialization and decrease neointimal proliferation. The Ultimaster™/Ultimaster™ Tansei™ coronary stent system is a cobalt–chromium, biodegradable polymer, sirolimus-eluting stent (Terumo, Tokyo, Japan) that received the Conformitè Européenne mark approval for clinical use in 2014/2018. This device has been the object of intense clinical evaluation in controlled randomized studies and observational registries. In this article, we analytically reviewed the available clinical data with a focus on the latest real-world evidence that demonstrates excellent performance in all of the clinical subsets.
Collapse
Affiliation(s)
- Elisa Gherbesi
- Department of Cardiology, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, University of Milan, Milano, Italy
| | | |
Collapse
|
28
|
Empagliflozin attenuates neointimal hyperplasia after drug-eluting-stent implantation in patients with type 2 diabetes. Heart Vessels 2020; 35:1378-1389. [PMID: 32399662 DOI: 10.1007/s00380-020-01621-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 05/01/2020] [Indexed: 12/28/2022]
|
29
|
Jimba T, Hashikata T, Matsushita M, Yamasaki M. Repetitive restenosis in a biodegradable polymer sirolimus-eluting stent with hypersensitivity reaction: a case report. EUROPEAN HEART JOURNAL-CASE REPORTS 2020; 4:1-5. [PMID: 32128478 PMCID: PMC7047045 DOI: 10.1093/ehjcr/ytaa001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 09/19/2019] [Accepted: 01/03/2020] [Indexed: 01/01/2023]
Abstract
Background Hypersensitivity reaction is a classic cause of in-stent restenosis (ISR) in coronary stents, typically reported in bare-metal stents and first-generation drug-eluting stents. Biodegradable polymer sirolimus-eluting stent (BP-SES) was developed with the concept of biocompatibility, and there has been no report of ISR of BP-SES with hypersensitivity reaction. Case summary An 81-year-old woman presented with ST-elevation acute inferior myocardial infarction. Primary percutaneous coronary intervention was performed for the culprit lesion in the left circumflex artery with a permanent polymer everolimus-eluting stent (PP-EES), followed by BP-SES implantation in the left anterior descending artery. Eight months later, coronary angiography showed total occlusion of the PP-EES and diffuse ISR in the BP-SES, treated with a paclitaxel-eluting balloon. Fluorodeoxyglucose with positron emission tomography showed increased uptake around the BP-SES, and cardiac magnetic resonance imaging revealed a late gadolinium-enhanced area around both stents. Four months later, she developed re-ISR in the BP-SES, and optical coherence tomography demonstrated diffuse-layered neointimal hyperplasia with microvascularization and peri-strut low-intensity area. She was successfully treated with coronary artery bypass grafting. Discussion Our case demonstrated repetitive short-term ISR of the BP-SES. Observation by both intravascular and non-invasive imaging modalities suggested the presence of hypersensitivity reaction localized in the stent. Hypersensitivity to the metal may be a possible mechanism because both stents are composed of L605 cobalt-chromium alloy. This is the first report of ISR of a BP-SES with hypersensitivity reaction. Non-invasive imaging can be useful to assess this critical condition.
Collapse
Affiliation(s)
- Takahiro Jimba
- Department of Cardiovascular Medicine, NTT Medical Center Tokyo, Higashigotanda 5-9-22, Shinagawa-ku, Tokyo 141-0022, Japan
| | - Takehiro Hashikata
- Department of Cardiovascular Medicine, NTT Medical Center Tokyo, Higashigotanda 5-9-22, Shinagawa-ku, Tokyo 141-0022, Japan
| | - Masashiro Matsushita
- Department of Cardiovascular Medicine, NTT Medical Center Tokyo, Higashigotanda 5-9-22, Shinagawa-ku, Tokyo 141-0022, Japan
| | - Masao Yamasaki
- Department of Cardiovascular Medicine, NTT Medical Center Tokyo, Higashigotanda 5-9-22, Shinagawa-ku, Tokyo 141-0022, Japan
| |
Collapse
|
30
|
Beneduce A, Ferrante G, Ielasi A, Pivato CA, Chiarito M, Cappelletti A, Baldetti L, Magni V, Prati E, Falcone S, Pierri A, De Martini S, Montorfano M, Parisi R, Rutigliano D, Locuratolo N, Anzuini A, Tespili M, Margonato A, Benassi A, Briguori C, Reimers B, Fabbiocchi F, Bartorelli A, Colombo A, Godino C. One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in diabetic patients: Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry). Catheter Cardiovasc Interv 2020; 96:255-265. [PMID: 31905259 DOI: 10.1002/ccd.28694] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Revised: 12/03/2019] [Accepted: 12/20/2019] [Indexed: 11/05/2022]
Abstract
BACKGROUND The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients. METHODS In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year. RESULTS At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p = .001), due to more cardiac deaths (3.4 vs. 1.1%; p = .002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p = .114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p = .526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p = .041), but similar rate of TLR (6 vs. 4%; p = .405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation. CONCLUSIONS This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.
Collapse
|
31
|
Codner P, Saada M, Sakhov O, Polad J, Malik FTN, Munir S, Mamas M, Crowley J, Monsegu J, Perez L, Kedev S, Austin D, Roguin A. Proximal Left Anterior Descending Artery Treatment Using a Bioresorbable Polymer Coating Sirolimus-Eluting Stent: Real-World Outcomes From the Multicenter Prospective e-Ultimaster Registry. J Am Heart Assoc 2019; 8:e013786. [PMID: 31787055 PMCID: PMC6912975 DOI: 10.1161/jaha.119.013786] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Guidelines recommend heart team discussion and coronary artery bypass graft consideration in patients with proximal left anterior descending (LAD) artery stenosis. Evidence suggests that outcomes of proximal LAD angioplasty might not differ from treatment of nonproximal LAD locations. We aim to determine clinical outcomes of patients undergoing percutaneous coronary intervention in the proximal LAD segment in comparison with nonproximal LAD angioplasty, using a thin-strut drug-eluting stent. Methods and Results In this analysis of the e-Ultimaster registry, patients undergoing angioplasty in the proximal LAD territory were compared with those treated in nonproximal LAD locations. Multivariate analysis and propensity score were used to adjust for differences among the groups. The primary outcome was target lesion failure: a composite of cardiac death, target-lesion-related myocardial infarction, and/or clinically driven target lesion revascularization at 1-year follow-up. Of the 17 805 patients (mean age, 64.2±11; 76% male), 5452 (30.6%) underwent proximal LAD and 12 353 (69.4%) nonproximal LAD percutaneous coronary intervention. Patients in the proximal LAD group had more multivessel disease (48.7% versus 43.5%; P<0.001) and 2-fold more bifurcations lesions (18.8% versus 9.2%; P<0.0001). After propensity-weighted adjustment, target lesion failure did not differ between the groups (3.3% versus 2.9%; P=0.17 for proximal LAD versus nonproximal LAD angioplasty, respectively). In multivariate analysis, proximal LAD treatment was not an independent predictor of target lesion failure (odds ratio, 1.07; 95% CI, 0.88-1.31; P=0.48). Conclusions At 1-year follow-up, patients had similar clinical outcomes independent of stenting location, questioning whether proximal LAD treatment should be regarded differently from stenting in any other coronary artery territory.
Collapse
Affiliation(s)
- Pablo Codner
- Department of Cardiology Hillel Yaffe Medical Center Hadera Israel.,The Rappaport Faculty of Medicine Technion-Israel Institute of Technology Haifa Israel
| | - Majdi Saada
- Department of Cardiology Hillel Yaffe Medical Center Hadera Israel.,The Rappaport Faculty of Medicine Technion-Israel Institute of Technology Haifa Israel
| | - Orazbek Sakhov
- Department of Interventional Cardiology City Heart Center Almaty Kazakhstan
| | - Jawed Polad
- Department of Cardiology Jeroen Bosch Hospital 's-Hertogenbosch The Netherlands
| | - Fazila Tun-Nesa Malik
- Department of Cardiology National Heart Foundation Hospital & Research Institute Dhaka Bangladesh
| | - Shahzad Munir
- Department of Cardiology Royal Wolverhampton Hospital Wolverhampton United Kingdom
| | - Mamas Mamas
- Keele Cardiovascular Research Group Center of Prognosis Research Institute of Primary Care Sciences Keele University Stoke on Trent United Kingdom
| | | | - Jacques Monsegu
- Institut Cardiovasculaire Groupe Hospitalier Mutualiste de Grenoble Grenoble France
| | - Luis Perez
- Hospital Guillermo Grant Benavente Concepcion Chile
| | - Sasko Kedev
- University Clinic of Cardiology Skopje Macedonia
| | - David Austin
- James Cook University Hospital Middleborough United Kingdom
| | - Ariel Roguin
- Department of Cardiology Hillel Yaffe Medical Center Hadera Israel.,The Rappaport Faculty of Medicine Technion-Israel Institute of Technology Haifa Israel
| | | |
Collapse
|
32
|
Moscarella E, Ielasi A, Beneduce A, Ferrante G, Pivato AC, Chiarito M, Cappelletti A, Perfetti G, Magni V, Prati E, Falcone S, Pierri A, De Martini S, Montorfano M, Parisi R, Rutigliano D, Locuratolo N, Anzuini A, Calabrò P, Tespili M, Margonato A, Benassi A, Briguori C, Fabbiocchi F, Reimers B, Bartorelli A, Colombo A, Godino C. One‐year clinical outcome of biodegradable polymer sirolimus‐eluting stent in patients presenting with acute myocardial infarction: Insight from the ULISSE registry. Catheter Cardiovasc Interv 2019; 94:972-979. [DOI: 10.1002/ccd.28305] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 03/19/2019] [Accepted: 04/10/2019] [Indexed: 11/10/2022]
Affiliation(s)
- Elisabetta Moscarella
- Department of Translational Medical SciencesUniversity of Campania Caserta Italy
- Cardiology Unit, Ospedale “Sant'Anna e San Sebastiano” Caserta Italy
| | - Alfonso Ielasi
- Cardiology Unit, Ospedale Bolognini, ASST Bergamo Est Seriate Italy
- Clinical and Interventional Cardiology UnitSant'Ambrogio Cardio‐Thoracic Center Milan Italy
| | | | | | | | - Mauro Chiarito
- Interventional Cardiology Unit, Ospedale Humanitas Rozzano Italy
| | | | | | | | | | - Stefania Falcone
- Cardiology Unit, Ospedale Humanitas Mater Domini Castellanza Italy
| | - Adele Pierri
- Cardiology Unit, Clinica Mediterranea Naples Italy
| | | | | | - Rosario Parisi
- Cardiology Unit, Ospedali Riuniti Marche Nord Pesaro Italy
| | | | | | - Angelo Anzuini
- Cardiology Unit, Ospedale Humanitas Mater Domini Castellanza Italy
| | - Paolo Calabrò
- Department of Translational Medical SciencesUniversity of Campania Caserta Italy
- Cardiology Unit, Ospedale “Sant'Anna e San Sebastiano” Caserta Italy
| | - Maurizio Tespili
- Cardiology Unit, Ospedale Bolognini, ASST Bergamo Est Seriate Italy
- Clinical and Interventional Cardiology UnitSant'Ambrogio Cardio‐Thoracic Center Milan Italy
| | | | | | | | | | - Bernhard Reimers
- Interventional Cardiology Unit, Ospedale Humanitas Rozzano Italy
| | | | | | - Cosmo Godino
- Cardiology Unit, Ospedale San Raffaele Milan Italy
| |
Collapse
|
33
|
One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in patients needing short dual antiplatelet therapy. Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry). Int J Cardiol 2019; 290:52-58. [PMID: 30917900 DOI: 10.1016/j.ijcard.2019.03.030] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 02/27/2019] [Accepted: 03/15/2019] [Indexed: 01/17/2023]
Abstract
BACKGROUND This study aimed to evaluate real-world clinical outcome of patients needing short dual antiplatelet therapy (S-DAPT) following PCI with Ultimaster® thin-strut, biodegradable polymer sirolimus-eluting stent (BP-SES), which was supposed to induce faster stent endothelialization and reduce device thrombogenicity. METHODS In this sub-group analysis of patients enrolled in the ULISSE registry, two groups were identified: 1) patients discharged with S-DAPT (≤3-month) due to high bleeding risk or need for urgent major non-cardiac surgery and 2) patients discharged with recommended DAPT (R-DAPT) duration (≥6-month). The primary ischemic-safety and bleeding-safety endpoints were TLF (composite of cardiac-death, target vessel MI, and clinically driven target lesion revascularization), and BARC major bleedings (≥type-3a) at 1-year follow-up. To account for events occurring before DAPT discontinuation we performed 3-month landmark analysis. RESULTS 82 patients (5%) were discharged with ≤3-month DAPT (57 ± 27 days), and 1558 patients (94%) were discharged with ≥6-month DAPT (318 ± 75 days). No significant differences between S-DAPT and R-DAPT group were observed in TLF at 1-year (7.9% vs. 4.6%). The rate of BARC major bleeding resulted significantly higher in S-DAPT group (3.9% vs. 0.3%; p = 0.001), with the majority of bleeding events occurring within 3 months. The landmark analysis showed no significant differences in BARC major bleedings between groups (1.4% vs. 0.3%; p = 0.142). CONCLUSIONS As compared to those treated with R-DAPT (≥6-month), patients needing -S-DAPT (≤3-month) after PCI with Ultimaster® BP-SES had similar rates of 1-year TLF and BARC major bleedings following early DAPT discontinuation.
Collapse
|
34
|
Roopmani P, Krishnan UM. Harnessing the pleiotropic effects of atorvastatin-fenofibrate combination for cardiovascular stents. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 92:875-891. [DOI: 10.1016/j.msec.2018.07.048] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Revised: 06/23/2018] [Accepted: 07/18/2018] [Indexed: 12/20/2022]
|
35
|
Godino C, Beneduce A, Ferrante G, Ielasi A, Pivato CA, Chiarito M, Cappelletti A, Perfetti G, Magni V, Prati E, Falcone S, Pierri A, De Martini S, Montorfano M, Parisi R, Rutigliano D, Locuratolo N, Anzuini A, Tespilli M, Margonato A, Benassi A, Briguori C, Fabbiocchi F, Reimers B, Bartorelli A, Colombo A. One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in all-comers population. Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry). Int J Cardiol 2018; 260:36-41. [DOI: 10.1016/j.ijcard.2018.02.014] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Accepted: 02/02/2018] [Indexed: 10/17/2022]
|
36
|
Wijns W, Valdes-Chavarri M, Richardt G, Moreno R, Íñiguez-Romo A, Barbato E, Carrié D, Ando K, Merkely B, Kornowski R, Eltchaninoff H, Stojkovic S, Saito S. Long-term clinical outcomes after bioresorbable and permanent polymer drug-eluting stent implantation: final five-year results of the CENTURY II randomised clinical trial. EUROINTERVENTION 2018; 14:e343-e351. [DOI: 10.4244/eij-d-18-00358] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
37
|
Lu S, Hu W, Zhang Z, Ji Z, Zhang T. Sirolimus-coated, poly(L-lactic acid)-modified polypropylene mesh with minimal intra-peritoneal adhesion formation in a rat model. Hernia 2018; 22:1051-1060. [PMID: 29777326 DOI: 10.1007/s10029-018-1782-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2017] [Accepted: 05/10/2018] [Indexed: 12/16/2022]
Abstract
PURPOSE This study evaluated the manufacturing method and anti-adhesion properties of a new composite mesh in the rat model, which was made from sirolimus (SRL) grafts on a poly(L-lactic acid) (PLLA)-modified polypropylene (PP) hernia mesh. METHODS PLLA was first grafted onto argon-plasma-treated native PP mesh through catalysis of stannous chloride. SRL was grafted onto the surface of PP-PLLA meshes using catalysis of 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and 4-dimethylaminopyridine (DMAP) in a CH2Cl2 solvent. Sprague-Dawley female rats received either SRL-coated meshes, PP-PLLA meshes, or native PP meshes to repair abdominal wall defects. At different intervals, rats were euthanized by a lethal dose of chloral hydrate and adhesion area and tenacity were evaluated. Sections of the mesh with adjacent tissues were assessed histologically. RESULTS Attenuated total reflection Fourier transformed infrared (ATR-FTIR) spectroscopy indicated the existence of a C=O group absorption peak (1724.1 cm-1), and scanning electron microscope morphological analysis indicated that the surface of the PP mesh was covered with SRL. Compared to the native PP meshes and PP-PLLA meshes, SRL-coated meshes demonstrated the greatest ability to decrease the formation of adhesions (P < 0.05) and inflammation. CONCLUSIONS The SRL-coated composite mesh showed minimal formation of intra-abdominal adhesions in a rat model of abdominal wall defect repair.
Collapse
Affiliation(s)
- S Lu
- Department of General Surgery, Affiliated ZhongDa Hospital (Jiang Bei), Southeast University, No. 211 Jianmin Road, Nanjing, 210009, Jiangsu, China.,Department of General Surgery, Institute for Minimally Invasive Surgery, Affiliated ZhongDa Hospital, Medical School, Southeast University, No. 87 Dingjiaqiao Road, Nanjing, 210009, Jiangsu, China
| | - W Hu
- Jiangsu Key Laboratory for Biomaterials and Devices, State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, No. 2 Sipailou, Nanjing, 21009, China
| | - Z Zhang
- Department of General Surgery, Institute for Minimally Invasive Surgery, Affiliated ZhongDa Hospital, Medical School, Southeast University, No. 87 Dingjiaqiao Road, Nanjing, 210009, Jiangsu, China
| | - Z Ji
- Department of General Surgery, Institute for Minimally Invasive Surgery, Affiliated ZhongDa Hospital, Medical School, Southeast University, No. 87 Dingjiaqiao Road, Nanjing, 210009, Jiangsu, China.
| | - T Zhang
- Jiangsu Key Laboratory for Biomaterials and Devices, State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, No. 2 Sipailou, Nanjing, 21009, China
| |
Collapse
|
38
|
Zheng Q, Chu Z, Li X, Kang H, Yang X, Fan Y. The Effect of Fluid Shear Stress on the In Vitro Release Kinetics of Sirolimus from PLGA Films. Polymers (Basel) 2017; 9:618. [PMID: 30965925 PMCID: PMC6418679 DOI: 10.3390/polym9110618] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 10/31/2017] [Accepted: 11/10/2017] [Indexed: 12/27/2022] Open
Abstract
Drug-carrying coatings of stents implanted in blood vessels are exposed to various blood flows. This study investigated the effect of fluid shear stress on the in vitro release kinetics of sirolimus from poly(lactic-co-glycolic acid) (PLGA) films. The homemade parallel plate flow chamber was used to exert quantitative shear stress on the sirolimus-carrying film. By adjusting the flow rate of the release media in the chamber, three levels of shear stress (3.6, 12.0, and 36.0 dyn/cm²) were respectively applied. For each level of shear stress employed, the release kinetics of sirolimus from the PLGA films exhibited a four-phase profile: an initial burst release phase (Phase I), a lag phase (Phase II), a second burst release phase (Phase III), and a terminal release phase (Phase IV). During Phases I and II, sirolimus was released slowly and in small amounts (<10%); however, during Phases III and IV, the drug release increased considerably. Comparisons of different shear stresses indicated that greater shear stress resulted in earlier and faster sirolimus release, with more cumulative drug release observed. PLGA film degradations (molecular weight reduction, mass loss, and surface topographical variations) were also investigated to better explain the observed drug release behavior. Consequently, fluid shear stress was found to significantly accelerate the release of sirolimus from the PLGA matrices. Therefore, this study could provide a practical method for evaluating the in vitro drug release from polymer matrices under uniform shear stress, and might help improve the design of biodegradable coatings on drug-eluting stents.
Collapse
Affiliation(s)
- Quan Zheng
- School of Biological Science and Medical Engineering, Beihang University, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing 100083, China.
- Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 102402, China.
| | - Zhaowei Chu
- Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Center for Rehabilitation Technical Aids, Beijing 100176, China.
| | - Xiaoming Li
- School of Biological Science and Medical Engineering, Beihang University, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing 100083, China.
- Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 102402, China.
| | - Hongyan Kang
- School of Biological Science and Medical Engineering, Beihang University, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing 100083, China.
- Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 102402, China.
| | - Xiao Yang
- School of Biological Science and Medical Engineering, Beihang University, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing 100083, China.
- Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 102402, China.
| | - Yubo Fan
- School of Biological Science and Medical Engineering, Beihang University, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing 100083, China.
- Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 102402, China.
- Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Center for Rehabilitation Technical Aids, Beijing 100176, China.
| |
Collapse
|
39
|
Mori H, Cheng Q, Lutter C, Smith S, Guo L, Kutyna M, Torii S, Harari E, Acampado E, Joner M, Kolodgie FD, Virmani R, Finn AV. Endothelial Barrier Protein Expression in Biodegradable Polymer Sirolimus-Eluting Versus Durable Polymer Everolimus-Eluting Metallic Stents. JACC Cardiovasc Interv 2017; 10:2375-2387. [PMID: 29102583 DOI: 10.1016/j.jcin.2017.06.059] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Revised: 06/16/2017] [Accepted: 06/29/2017] [Indexed: 12/20/2022]
Abstract
OBJECTIVES This study sought to investigate endothelial coverage and barrier protein expression following stent implantation. BACKGROUND Biodegradable polymer drug-eluting stents (BP-DES) have been purported to have biological advantages in vessel healing versus durable polymer DES (DP-DES), although clinical trial data suggest equipoise. METHODS Biodegradable polymer-sirolimus-eluting stents (BP-SES), durable polymer-everolimus-eluting stents (DP-EES), and bare-metal stents (BMS) were compared. In the rabbit model (28, 45, and 120 days), stented arteries underwent light microscopic analysis and immunostaining for the presence of vascular endothelium (VE)-cadherin, an endothelial barrier protein, and were subjected to confocal microscopy and scanning electron microscopy. A cell culture study in stented silicone tubes was performed to assess cell proliferation. RESULTS Light microscopic assessments were similar between BP-SES and DP-EES. BMS showed nearly complete expression of VE-cadherin at 28 days, whereas both DES showed significantly less with results favoring BP-SES versus DP-EES (39% coverage in BP-SES, 22% in DP-EES, 95% in BMS). Endothelial cell morphologic patterns differed according to stent type with BMS showing a spindle-like shape, DP-EES a cobblestone pattern, and BP-SES a shape in between. VE-cadherin-negative areas showed greater surface monocytes regardless of type of stent. Cell proliferation was suppressed in both DES with numerically less suppression in BP-SES versus DP-EES. CONCLUSIONS This is the first study to examine VE-cadherin expression after DES. All DES demonstrated deficient barrier expression relative to BMS with results favoring BP-SES versus DP-EES. These findings may have important implications for the development of neoatherosclerosis in different stent types.
Collapse
Affiliation(s)
| | - Qi Cheng
- CVPath Institute, Gaithersburg, Maryland
| | | | | | - Liang Guo
- CVPath Institute, Gaithersburg, Maryland
| | | | - Sho Torii
- CVPath Institute, Gaithersburg, Maryland
| | | | | | | | | | | | - Aloke V Finn
- CVPath Institute, Gaithersburg, Maryland; University of Maryland, Baltimore, Maryland.
| |
Collapse
|